Condensate drain
BEKOMAT® 32U Vario F (BM32UVF)
01-1719
Dear customer,
Thank you for deciding in favor of the BEKOMAT® 32U Vario F condensate drain. Please read the
installation and operating instructions carefully before mounting and starting up the BEKOMAT® 32U Vario F,
and follow our directions. Perfect functioning of the BEKOMAT® 32U Vario F, and thus reliable condensate
discharge, can only be guaranteed when the provisions and notes stipulated here are strictly adhered to.
Pos : 3 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/Anl eitung beac hten s/w T ypensc hild @ 1\mod_1290772180142_15098.doc x @ 20492 @ @ 1
Pos : 4 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/Gefahr Warnung Vorsic ht s/w @ 0\mod_1213265685174_15098.doc x @ 15189 @ @ 1
Pos : 5 /Beko Tec hnisc he Dokumentati on/Pi ktogramme/G+W+ V N etz spannung s /w @ 0\mod_1213266193701_15098.doc x @ 15191 @ @ 1
General danger symbol (danger, warning, caution) for supply voltage and supply voltage-
carrying plants components
Pos : 6 /Beko Tec hnisc he Dokumentati on/Ü bersc hriften/1/Sic herheits hinweise @ 0\mod_1183637609261_15098.doc x @ 15102 @ 1 @ 1
2 Safety instructions
Pos : 7 /Beko Tec hnisc he Dokumentati on/Gl obal e T exte/Allgemei ner Hi nweis BM @ 0\mod_1183615737313_15098.doc x @ 15099 @ @ 1
Pos : 8 /Beko Tec hnisc he Dokumentati on/Sic herheit/Hi nweis Anlei tung BEKO ( männl. N ame) @ 0\mod_1184147787557_15098.doc x @ 15120 @ @ 1
Please check whether or not these instructions correspond to the device type.
Adhere to all advice given in these operating instructions. They include essential information
which must be observed during the installation, operation and maintenance. Therefore it is
imperative for the service technician and the responsible operator / technical staff to read these
operating instructions prior to installation, start-up and maintenance.
The operating instructions must be accessible at any time at the place of application of the
BEKOMAT® 32U Vario.
In addition to these operating instructions, local or national regulations must be complied with,
if necessary.
Make sure that the BEKOMAT® 32U Vario is operated only within the permissible limit values
indicated on the type plate. Any deviation involves a risk for persons and materials, and may
result in malfunction and service failures.
If you have any queries regarding these installation- and operating instructions, please contact
BEKO TECHNOLOGIES CORP.
Pos : 9 /Beko Tec hnisc he Dokumentati on/Sic herheit/Gefahr Druc kluft @ 0\mod_1184148143854_15098.doc x @ 15121 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos : 10 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen Druc kluft BM @ 0\mod_1184148284291_15098.doc x @ 15123 @ @ 1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos : 11 /Beko T ec hnis che D okumentati on/Sic her hei t/Gefahr Netzs pannung 1 s/w @ 0\mod_1184148186948_15098.doc x @ 15122 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos : 12 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen N etzs pannung BM 31U/32U/33U @ 7\mod_1390467197804_15098.doc x @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
• All types of electrical works must be carried out by authorized and qualified personnel only.
Pos : 13 /Beko T ec hnis che D okumentati on/Sic her hei t/Sic herheits hinweis e, weitere BM ( nicht Ex, nic ht IF) @ 0\mod_1183616103770_15098.doc x @ 15100 @ @ 1
Additional advice:
• The removed control unit has no IP degree of protection.
• During installation, use spanner flat at the feed pipe (wrench size SW27) as a back rest.
• The service unit must not be dismantled.
Pos : 15 /Beko T ec hnis che D okumentati on/Sic her hei t/Vorsic ht F ehlfunktion @ 0\mod_1214378096290_15098.doc x @ 15237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos : 16 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen F ehl funkti onen BM @ 0\mod_1214378434025_15098.doc x @ 15238 @ @ 1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the BEKOMAT in accordance with the instructions in this
operating manual
3 Proper use
Pos : 19 /Beko T ec hnis che D okumentati on/Besti mmungsgemäß e Ver wendung/BEKOM AT/Bes ti mmung. Ver wend. BM 31/32/33 +U @ 0\mod_1213345398718_15098.doc x @ 15218 @ @ 1
• The BEKOMAT® 32U Vario F is an electronically level-controlled condensate drain for compressed-air
plants.
• The device is employed within the permissible performance parameters (see "Technical data").
• The BEKOMAT® 32U Vario F is able to drain condensate under operating pressure from the plant
components virtually without compressed-air loss.
• For its function, the BEKOMAT® 32U Vario F requires an supply voltage and an operating pressure (see
"Technical data").
• As far as the employment in plants with increased demands on compressed air is concerned (food
industry, medical technology, laboratory equipment, special processes etc.), the operator must decide
on measures for the monitoring of the compressed-air quality. These have an effect on the safety of the
subsequent processes and may prevent damage to persons and plants.
• It is the task of the operator to ensure that the indicated conditions are met during the entire operating
time.
Pos : 20 /Beko T ec hnis che D okumentati on/Besti mmungsgemäß e Ver wendung/BEKOM AT/Bes ti mmung. Ver wend. BM Vario (Z usatz) @ 0\mod_1185783975983_15098.doc x @ 15162 @ @ 1
• The BEKOMAT Vario is a condensate drain whose properties are adjusted especially to prescribed
applications.
• BEKOMAT Vario devices must not be employed at drain points other than those prescribed by the
supplier, as this may result in malfunction and damage in the compressed-air system and at the
compressed-air consumers.
• BEKOMAT Vario devices must not be replaced by other BEKOMAT-types, as this may result in
malfunction and damage in the compressed-air system and at the compressed-air consumers.
Pos : 21 /Beko T ec hnis che D okumentati on/Übersc hriften/1/Aussc hluss vom Anwendungs ber eich @ 0\mod_1236003439359_15098.doc x @ 15308 @ 1 @ 1
• The BEKOMAT® 32U Vario F as a condensate drain alone cannot guarantee a defined compressed-air
quality, for this purpose, other additional technical devices are required.
• BEKOMAT® 32U Vario F is not suitable for use in plants carrying vacuum or atmospheric ambient
pressure or in ex-areas.
• The BEKOMAT® 32U Vario F must not be exposed to permanent direct solar or thermal radiation.
• The BEKOMAT® 32U Vario F must not be installed and operated in areas with an aggressive
atmosphere.
Pos : 23 /Beko T ec hnis che D okumentati on/Besti mmungsgemäß e Ver wendung/BEKOM AT/Aus schl uß Anwendung BM nic ht für fros tgefähr dete Bereic he (Zusatz) @ 0\mod_1216106439206_15098.doc x @ 15249 @ @ 1
• The BEKOMAT® 32U Vario F is not heatable and, therefore, not suitable for the use in areas where frost
is likely to occur.
Pos : 24 /Beko T ec hnis che D okumentati on/Besti mmungsgemäß e Ver wendung/BEKOM AT/Aus schl uß Anwendung BM 31/32 nic ht fürC O2- Anwendg. +U @ 0\mod_1242828696240_15098.doc x @ 15316 @ @ 1
5 Technical data
Pos : 27 /Beko T ec hnis che D okumentati on/Tec hnische D aten/BEKOM AT/T ec hn. D aten BM 3xU + UC + GOST (o.Leistg.) @ 5\mod_1358843578945_15098.doc x @ 30477 @ @ 1
6 Electrical data
Pos : 30 /Beko T ec hnis che D okumentati on/El ektrisc he Daten/BEKOM AT/Elektrische D aten BM 32U/33U @ 4\mod_1357737405732_15098.doc x @ 29609 @ @ 1
7 Dimension drawing
Pos : 33 /Beko T ec hnis che D okumentati on/Tec hnische D aten/M assz eichnung @ 0\mod_1184569815280_15098.doc x @ 15135 @ @ 1
8 Function
Pos : 36 /Beko T ec hnis che D okumentati on/Funkti on/BEKOMAT/BM Vario-F unktion @ 0\mod_1185779978265_15098.doc x @ 15161 @ @ 1
Via the inlet line (1), the condensate flows into the
BEKOMAT® 32U Vario and accumulates in the
housing (2).
A capacitive functioning sensor (3) continuously
registers the filling level.
Pos : 37 /Beko T ec hnis che D okumentati on/Funkti on/BEKOMAT/BM 32U/33U LED-T aster-Funkti on @ 4\mod_1354691493582_15098.doc x @ 29067 @ @ 1
Alarm mode:
In the event that the BEKOMAT is not empty after one
minute, a trouble indication is released:
Switching sequence of the valve in the alarm • The alarm LED flashes.
mode • The alarm relay switches over (the signal can be
picked off potential-freely).
• The valve opens every four minutes for 7.5
seconds.
• When the malfunction has been eliminated, the
BEKOMAT will switch back automatically into the
normal mode.
Possible trouble sources include :
• Mistakes during installation
• Dropping below the minimum pressure
• Excessive accumulation of condensate (excess
load)
• Blocked / obstructed outlet line
• Extreme amount of dirt particles
Trouble indication via a potential-free contact
• Frozen pipe work
Pos : 39 /Beko T ec hnis che D okumentati on/Funkti on/BEKOMAT/BM 31U/32U/BM 31U/32U/33U+ Vari o Abl.- War tungs mel dg. akti v ( nicht 32U FMK + IF) Wartungsinter vall @ 5\mod_1371731964818_15098.doc x @ 31047 @ @ 1
9 Installation
Pos : 42 /Beko T ec hnis che D okumentati on/Sic her hei t/Gefahr Druc kl uft @ 0\mod_1184148143854_15098.doc x @ 15121 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos : 43 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen Druc kluft BM @ 0\mod_1184148284291_15098.doc x @ 15123 @ @ 1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos : 44 /Beko T ec hnis che D okumentati on/Sic her hei t/Vorsic ht F ehlfunktion @ 0\mod_1214378096290_15098.doc x @ 15237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos : 45 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen F ehl funkti onen BM @ 0\mod_1214378434025_15098.doc x @ 15238 @ @ 1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the BEKOMAT in accordance with the instructions in this
operating manual
Note
Pos : 47 /Beko T ec hnis che D okumentati on/Installati on/BEKOMAT /BM 32/33 +U Vario Installati onshi nweis e @ 0\mod_1232095567742_15098.doc x @ 15292 @ @ 1
Installation instructions:
wrong correct
Pressure differences!
Continuous slope!
Deflector area!
No venting line!
10 Electrical installation
Pos : 50 /Beko T ec hnis che D okumentati on/Sic her hei t/Gefahr Netzs pannung 1 s/w @ 0\mod_1184148186948_15098.doc x @ 15122 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos : 51 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen N etzs pannung BM 31U/32U/33U @ 7\mod_1390467197804_15098.doc x @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
• All types of electrical works must be carried out by authorized and qualified personnel only.
Pos : 52 /Beko T ec hnis che D okumentati on/Installati on/BEKOMAT /El ektrInstallation Hi nweis e BM32U/33U allg. @ 4\mod_1357728884079_15098.doc x @ 29541 @ @ 1
Note:
Pos : 53 /Beko T ec hnis che D okumentati on/Installati on/BEKOMAT /Kl emmenbel egung BM 32U/33U @ 4\mod_1354692952721_15098.doc x @ 29135 @ @ 1
CO
NC
L/+
• X 1.2 N/-
N/-
L = Outer conductor
3.1 external test (IN1)
N = Neutral conductor
2.3 normally closed
2.1 normally open
2.2 common
1.2 neutral
1.1 phase
3.2 GND
CO
• X 1.2 N/-
NC
L/+
N/-
2.2 common
1.1 power
1.2 power
3.2 GND
GND
IN1
NO
CO
NC
L/+
N/-
• X 2.2 com.
• X 2.3 n.c.
n.c. - com. closed in the event of malfunction or power failure
(closed current principle)
3.1 external test (IN1)
2.3 normally closed
1.2 power
• X 3.2 GND
Contacts connected = test active = discharge
Contacts open = test inactive
The contacts X 3.1 -3.2 are not potential-free.
Note:
At a low-voltage supply (< 50 VAC / < 75 VDC), only use a protective extra-low-voltage.
Tighten the threaded cable connection with a slightly sealing effect.
Pos : 54 /Beko T ec hnis che D okumentati on/Installati on/BEKOMAT /E- Schema @ 0\mod_1233758178163_15098.doc x @ 15305 @ @ 1
Electric diagram
Pos : 55 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which are
not secured.
Pos : 58 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen Druc kluft BM @ 0\mod_1184148284291_15098.doc x @ 15123 @ @ 1
Measures:
• Do not exceed the maximum operating pressure (see type plate).
• Only carry out service measures when the system is pressure less.
• Use pressure-resistant installation material only.
• The feed pipe must be tubed firmly. Discharge pipe: short, fixed pressure hose onto pressure-resistant
pipe.
• Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos : 59 /Beko T ec hnis che D okumentati on/Sic her hei t/Gefahr Netzs pannung 1 s/w @ 0\mod_1184148186948_15098.doc x @ 15122 @ @ 1
Danger!
Supply voltage!
There is the risk of an electric shock involving injury or death when coming into contact
with non-insulated components carrying supply voltage.
Pos : 60 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen N etzs pannung BM 31U/32U/33U @ 7\mod_1390467197804_15098.doc x @ 38070 @ @ 1
Measures:
• During electric installations, all regulations in force need to be adhered to (e.g. VDE 0100 / IEC 60364).
• When the control unit is open, service and installation works must only be undertaken when the
system is deactivated.
• The removed control unit has no IP degree of protection.
• All types of electrical works must be carried out by authorized and qualified personnel only.
Pos : 61 /Beko T ec hnis che D okumentati on/Sic her hei t/Vorsic ht F ehlfunktion @ 0\mod_1214378096290_15098.doc x @ 15237 @ @ 1
Caution!
Malfunction during operation!
Through incorrect installation and poor maintenance, malfunction may occur at the
BEKOMAT.
Condensate which is not discharged may cause damage to plants and in production
processes.
Pos : 62 /Beko T ec hnis che D okumentati on/Sic her hei t/Maßnahmen F ehl funkti onen BM @ 0\mod_1214378434025_15098.doc x @ 15238 @ @ 1
r
Measures:
• Condensate drainage which is reliable in performance directly optimizes the compressed-air quality.
• To prevent damage and breakdowns, it is imperative to observe the following:
• Exact compliance with the specifications of use and with the performance parameters of the
BEKOMAT, in connection with the case of application (see "Proper use" section)
• Exact compliance with the installation- and operation instructions in this manual
• Regular maintenance and control of the BEKOMAT in accordance with the instructions in this
operating manual
Note
Pos : 65 /Beko T ec hnis che D okumentati on/Wartung/BEKOM AT/Wartung BM 32U Vario ( nicht IF) stand-al one 1x8760h @ 6\mod_1375284578823_15098.doc x @ 32921 @ @ 1
Maintenance recommendation:
Failure during the start of the Separate the device from the supply
program voltage and reactivate after > 5 s
Circuit board defective Check the circuit boards for possible
damage
Condensate discharge
only when the test
button is pressed
Service unit defective or dirty Replace the service unit
15 Accessories
Pos : 76 /Beko T ec hnis che D okumentati on/Ers atzteile Verbr auchs materialien Zubehör/BEKOMAT/H altewi nkel BM 31/32 / 31U/32U SA @ 0\mod_1232368058757_15098.doc x @ 15294 @ @ 1
Pos : 77 /Beko T ec hnis che D okumentati on/Ers atzteile Verbr auchs materialien Zubehör/BEKOMAT/Abl auf- Set BM 31/32 / 31U/32U @ 0\mod_1232623241656_15098.doc x @ 15300 @ @ 1
16 Declaration of conformity
Pos : 80 /Beko T ec hnis che D okumentati on/Zertifi kate/Er klär ung en/BEKOMAT 31U-33U-EG-Konfor mSc an @ 5\mod_1358418648413_0.doc x @ 30239 @ @ 1
EC Declaration of Conformity
We hereby declare that the products indicated hereafter comply with the stipulations of the relevant
directives and technical standards. This declaration only refers to products in the condition in which they
have been placed into circulation. Parts which have not been installed by the manufacturer and/or
modifications which have been implemented subsequently remain unconsidered.
The devices with a supply voltage of 24...48 VAC and 18...72 VDC do not come under the scope of the Low-
Voltage Directive.
Pos : 83 /Beko T ec hnis che D okumentati on/Globale Texte/Hinweis Ü bers etzg. d. Orig.anl eitg. @ 1\mod_1260433478358_15098.doc x @ 17131 @ @ 1
Pos : 84 /Beko T ec hnis che D okumentati on/Globale Texte/Hinweis Original anl eitung @ 1\mod_1260433346280_15098.doc x @ 17097 @ @ 1
.
Pos : 85 /Beko T ec hnis che D okumentati on/Globale Texte/Vorbehalts klaus el @ 0\mod_1213704033153_15098.doc x @ 15236 @ @ 1
=== Ende der Liste für T extmar ke Inhalt ===
Circuit board 23 N
Components 23 No condensate discharge 22
Condensate discharge disturbed 22 No LED lights up 22
Control 19 O
Control unit 21
Order number 23, 24
D
P
Danger compressed air 4, 13, 19
Piktogramme 4
Danger supply voltage 5, 16, 19
Pressure differences 15
Data 7
Proper use 6
Declaration of conformity 26
Q
Deflector area 15
Degree of protection 5, 16, 19 Qualified personnel 5, 16, 19
Design shell 23 R
Dimension drawing 9 Recommended spare parts 23
Dimensions 9
S
E
Safety instructions 4
Electric diagram 18 Self-test 11
Electrical data 8 Sensor 23
Electrical data 8 Sensor tube plate 21
Electrical installation 16 Service measures 4, 13, 19
Elements 23 Service unit 20, 23
Exclusion from the scope of application 6 Sets of spare parts 23
Exclusion of a field of application 6 Slope 15
F Spare parts 5, 23
Failure 22 Symbole 4
Fault clearance 22 T
Fault diagnosis 22 Technical data 7
Fault elimination 22 Trouble sources 11
Field of application 6 Troubleshooting 22
Filling level 10
U
Function 10
Upper part of the cover 23
H
Hose connector 23
I
Installation 13