Legend and Terms: 1. 2. 3.: Smoke Detector (Addressable) Fire Alarm Control Panel Manual Pull Station W/ Strobe

This document provides general notes and a legend for an electrical fire alarm system. The general notes specify that all electronic works must comply with local authorities and utility companies, and must be installed by licensed personnel supervised by an engineer. The legend defines common components of the system including smoke detectors (SD), the fire alarm control panel (FACP), and manual pull stations (M). It also labels the units in a multi-unit building that the system will serve and protect.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views1 page

Legend and Terms: 1. 2. 3.: Smoke Detector (Addressable) Fire Alarm Control Panel Manual Pull Station W/ Strobe

This document provides general notes and a legend for an electrical fire alarm system. The general notes specify that all electronic works must comply with local authorities and utility companies, and must be installed by licensed personnel supervised by an engineer. The legend defines common components of the system including smoke detectors (SD), the fire alarm control panel (FACP), and manual pull stations (M). It also labels the units in a multi-unit building that the system will serve and protect.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES: LEGEND AND TERMS:

1. ALL ELECTRONIC WORKS HERE IN 1. SD SMOKE DETECTOR (ADDRESSABLE) PROPERTY LINE PROPERTY LINE

SHALL BE DONE IN ACCORDANCE ROLL


DOWN
LADDER
WITH PROVISION OF THE LOCAL
ENFORCING AUTHORITIES AND THE 2. FACP FIRE ALARM CONTROL PANEL UNIT 18

REQUIREMENTS OF THE UTILITY UNIT 7 SD FIRE


SD FIRE
EXIT EXIT
TELEPHONE COMPANY.
3. MANUAL PULL STATION W/ STROBE LANDLORDS'

HALLWAY
M BEDROOM UNIT 15
SD
2. ALL ELECTRONIC WORKS HERE IN SD

INCLUDE SHALL BE EXECUTED BY


UNIT 16

HALLWAY
PERSONNEL WITH ELECTRICAL UNIT 6
EXPERIENCE UNDER THE DIRECT SD SD SD SD
UNIT 14
SUPERVISION OF A FULL TIME
LICENSED ELECTRONIC ENGINEER. SD

WORKS SHALL BE HEALTHY PLACED


SECURELY FASTENED AND T&B T&B
PROPERLY LICENSED. TO FACP LANDLORDS' TO FACP
M UNIT M

FACP
SD
UNIT 13
3. THE CONTRACTOR SHALL VERIFY SD
COMMON
AND ORIENT THE ACTUAL LOCATION DINING
OF TAPPING POINT FOR OPEN
SD ABOVE SD
CONNECTION TO COMMUNICATION
COMMON UNIT 5
OPEN ABOVE

SUPPLY. DINING LAUNDRY


SD
AREA

4. ALL MATERIALS SHALL BE BRAND


NEW AND SHALL CONFORM WITH T&B T&B T&B

HALLWAY
T&B
THE PROVISION OF THE UNDER UNIT 12
WRITERS LABORATORIES INC. IN SD
UNIT 4
EVERY CASE WHERE SUCH A SD

HALLWAY
STANDARD HAS BEEN ESTABLISHED.
UNIT 2 UNIT 9
SD SD
SD SD
5. ALL CONDUITS MUST BE PROTECTED UNIT 11
ELEV. + 3.25m.

AGAINST DAMAGE BY THE ENTRANCE UNIT 3 SD

OF WATER AND FOREIGN MATTERS SD


DURING CONSTRUCTION. ALL ENDS
UNIT 1 UNIT 8
OF CONDUITS SHALL BE PLUGGED
SD SD
TO INCLUDE MOISTURE AND DUST
IMMEDIATELY AFTER THE CONDUITS
SD
ARE PLACED.
UNIT 10
W
1 DN
6. UNLESS OTHERWISE SPECIFIED, ALL BUILDING LINE ABOVE

ELECTRONIC WIRING INSTALLATION UP PARKING AREA


CANOPY LINE ABOVE

SHALL BE USED RSC. THE MINIMUM


SIZE OF CONDUIT SHALL BE 15MM
DIA.
SF AREA:
115.74 SQM.
7. ALL RACEWAYS WALL AND FLOOR
PENETRATIONS SHALL BE PROVIDED
WITH FIRE BARRIER OF THE FDAS ALARM SYSTEM FDAS ALARM SYSTEM
APPROVED TYPE. GROUND FLOORPLAN SECOND FLOORPLAN
SCALE 1:120 MTS. SCALE 1:120MTS

DESIGN BY :
PROFESSIONAL ELECTRONICS ENGINEER PROJECT TITLE : PROJECT OWNER : SHEET CONTENT : SHEET NO .

PROPOSED TWO STOREY MS. CAROL LACANDAZO DATE :

REG. NO. ;

TIN. NO. ;
PTR NO. ;

DATE ;
BOARDING HOUSE AS SHOWN
ECE-2
ADDRESS ; LOCATION : MARASBARAS, TACLOBAN CITY LOCATION : DATE :