P N M T: PNMT (Java Version) Operation Manual
P N M T: PNMT (Java Version) Operation Manual
P
ASOLINK
N
ETWORK
M ANAGEMENT
Operation Manual
(for PASOLINK V4)
T
ERMINAL
NEC Corporation
Copyright © 2005
Submission Prohibited ROI-S05592
NEC Internal Use Only
Table of Contents
DOCUMENT WARRANTY ......................................................................................................... 1
-i-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.16.3 Selecting TX Mute Status....................................................................................................... 37
2.16.4 Selecting Carrier Wave Status............................................................................................... 37
2.16.5 Selecting BER ALM >> AIS .................................................................................................. 38
2.16.6 Selecting and Setting ATPC Manual Status........................................................................... 38
2.16.7 TX Switch (For 1+1 Hot Standby system only) ..................................................................... 39
2.16.8 RX Switch (For 1+1 system only).......................................................................................... 39
2.17 EQUIPMENT SETUP .........................................................................................................40
2.17.1 Equipment Configuration Monitor ........................................................................................ 40
2.17.2 Setting the Frequency Plan.................................................................................................... 43
2.17.3 Setting the MTPC TX Power ................................................................................................. 43
2.17.4 Setting the Bit Rate ................................................................................................................ 44
2.17.5 Setting the Frame ID ............................................................................................................. 44
2.17.6 Setting the BER Threshold..................................................................................................... 45
2.17.7 Setting the AIS SEND ............................................................................................................ 45
2.17.8 Setting the AIS RCVD............................................................................................................ 45
2.17.9 Setting the TX Power Control................................................................................................ 45
2.17.10 Setting the ATPC RX Threshold ............................................................................................ 46
2.17.11 Setting the ATPC MAX Power............................................................................................... 46
2.17.12 Setting the ATPC MIN Power................................................................................................ 46
2.17.13 Setting the ODU ALM Mode ................................................................................................. 47
2.17.14 Setting the Redundancy Status............................................................................................... 47
2.17.15 Setting the Channel Usage Error Status................................................................................ 47
2.17.16 Setting the MAINT on AIS Activation Status ......................................................................... 48
2.17.17 Setting the TX Switch Priority Status .................................................................................... 48
2.17.18 Setting the MAIN LAN INTFC............................................................................................... 49
2.17.19 Setting the FE Link Down Status........................................................................................... 50
2.17.20 Setting the Service Channels (SC4/SC5) ............................................................................... 50
2.17.21 Editing the NE Name ............................................................................................................. 50
2.17.22 Editing the Note for NE ......................................................................................................... 51
2.18 LINK PERFORMANCE MONITOR ........................................................................................52
2.18.1 Viewing Summary Link Performance Monitor ...................................................................... 52
2.18.2 Threshold Setting................................................................................................................... 55
2.18.3 Link Performance Monitor (Daily Data) window ................................................................. 56
2.18.4 Link Performance Monitor (15-min Data) window............................................................... 57
2.18.5 All Data Reset........................................................................................................................ 58
2.19 NE STORED LOG ............................................................................................................59
2.19.1 NE Stored Log Monitor ......................................................................................................... 59
2.20 VERSION TAB ................................................................................................................60
2.20.1 Version Monitor..................................................................................................................... 60
2.21 LICENSE IMPORT ............................................................................................................61
2.21.1 License import ....................................................................................................................... 61
- ii -
Submission Prohibited ROI-S05592
NEC Internal Use Only
Document Warranty
1. The information contained in this document is subject to change without prior notice.
2. The PNMS/PNMT screenshots in this manual are only examples. Screens will vary according
to equipment configurations, equipment operation modes, setting parameters, PNMS/PNMT
application program version, etc. Screens contained in this manual are current at the moment
of publication and may differ slightly from the actual screens on your PNMS/PNMT.
3. To use this manual, you need a sound understanding of the restrictions, limitations and
precautions involved in operating the equipment properly. Always refer to the equipment
manual to ensure proper operation of the equipment.
-1-
Submission Prohibited ROI-S05592
NEC Internal Use Only
1 Getting Started
1.1 Introduction
The PASOLINK Network Management Terminal (PNMT) was developed by NEC to manage its
PASOLINK fixed point-to-point wireless access system networks. The PNMT is a scaled down
version of the PASOLINK Network Management System (PNMS) that is designed as a
maintenance tool for field engineers to locally and remotely monitor alarms, control points,
generate reports, and archive data, all within a familiar graphical user interface, and all in real time.
The PNMT is a Mobile laptop computer fitted with the NEC PNMT software package that
interfaces and controls NEC series short haul wireless communications equipment.
This software package remotely monitors and controls the status and configuration of an entire
Pasolink network with associated equipment including the performance of the actual microwave
links.
-2-
Submission Prohibited ROI-S05592
NEC Internal Use Only
1.3 PNMT Communication Interfaces
1.3.1 Communications
Communications between the PNMT and the wireless communications network equipment can be
a) LA Port Interface
The LA Port is on the front of the Pasolink unit.
The LA Port consists of a DB15 connector that plugs into the PM installed in IDU via a serial
cable which connects to the relevant communications port of the PNMT Computer.
The LA Port has the following properties:
The following table shows cabling pin allocation for the connection between LA Port and the
PNMT PC.
LA PORT PC (PNMT)
Connector
RS-232C
1 LCT-TXD 1
2 GND 2
3 LCT-RXD 3
4 LCT-RTS 4
5 LCT-CTS 5
6 6
7 7
8 GND 8
9 9
10 10
11 PNMT-CTS 11 1 1 CD
12 PNMT-RTS 12 2 2 RD
13 PNMT-RXD 13 3 3 TD
14 GND 14 4 4 DTR
15 PNMT-TXD 15 5 5 GND PC (PNMT)
6 6 DSR
7 7 RTS
8 8 CTS
9 9 RI
-3-
Submission Prohibited ROI-S05592
NEC Internal Use Only
NOTE
When the cable between PNMT and NE is un plugged,
communications will be disrupted and a message
prompting reconnection will appear a few minutes later
on the PNMT screen. Please wait for the message to
appear before changing/reinserting the cable connection
into the NE.
-4-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2 System Operation & Maintenance
This chapter explains the menu structure and procedures for operating of the PNMT. The
explanation uses typical PNMT screenshots to illustrate the menu hierarchy.
o Title bar
The title bar is used to indicate the title of a window.
o Block Diagram
The block diagram shows the equipments comprising the PASOLINK wireless
communication system. Its main purpose in window is to display the current summary of the
alarm statuses of the equipment. You can click a specific block to display the status of
equipment in the data window.
o Data window
This window displays in detail the status and alarm items of a specific equipment of the NE.
You can select the tab or the block of a specific part that you wish to monitor in the data
window.
o Tabs
To view the status and alarms in the PASOLINK radio, click tab at the bottom of the Data
window.
o Command Button
The command button is used to enter (on the computer) the data specified in pop-up window.
o Selectable Field
The selectable field is a standard Windows input field where the user can scroll down on a
list of values available for that option.
o Login User
This indicates the user who is currently logged-in in to the PNMT.
-5-
Submission Prohibited ROI-S05592
NEC Internal Use Only
One Touch
Expandable
Title Bar NE-Specific Menu Bar Block Diagram
Button
Common
Menu Bar
Common
Tool Bar
Data
window
Tabs
Login User
Figure 1 Standard Components of PNMT window
-6-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.2 Launching the PNMT Application
To start PNMT:
1. Turn system power ON.
NOTE
Connect the PNMT cable 30 seconds after IDU power has
been turned ON and make sure that the PNMT cable is
connected between Com 1 port of the PNMT PC and the
PNMT port of the IDU.
2. Login to Windows.
3. Click Start Programs PNMTj Pnmt, then continue to the login window.
NOTE
Please do not change the clock settings of your computer
once PNMT has started.
-7-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.3 Login
Users are registered by means of login name and password.
To protect the network and the network management system from unauthorized access or
modifications, five levels of users with different access privileges are defined (refer to the table
shown in section 2.3.1 User Access Privilege Levels). The functions that are available depend on
the individual user’s access level.
The highest or administrator level has full access to the network and the management system.
To login:
1. Start PNMT and the Login window appears.
Login window
2. Enter the <User name>.
3. Enter the valid <Password> for the specific user.
4. Click [Login].
If you wish to exit the program, click [Exit].
-8-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.3.1 User Access Privilege Levels
: Available, –: Not Available
Functions User Name and Accessible Functions
Category ITEM Monitor User Local Remote Admin
Menu-System Change Password
Alarm Buzzer –
Connect (Remote Login) – – –
Exit
Menu-Refresh Refresh
Menu-Help Help
About
License
IDU Common AIS SEND Report –
WS Usage (WS option) –
WS AIS RCVD Report (WS option) –
CH (LB1) – –
CH (LB2) – –
CH (Usage) –
CH (AIS RCVD Report) –
MAINT MAINT –
TX Mute – –
CW – –
BER ALM >> AIS –
ATPC Manual – –
TX Switch (1+1) – –
RX Switch (1+1) – –
Equipment ODU Frequency Plan (CH) – –
Configuration MTPC TX Power – –
TX Power Control – –
ATPC RX Threshold – –
ATPC MAX Power – –
ATPC MIN Power – –
ODU ALM Mode – –
IDU/Main Signal BIT Rate (Bit Rate Free Type) – – – –
Status/Setup Redundancy – – – –
Frame ID – –
BER Threshold –
AIS RCVD –
AIS SEND –
Channel Usage Error –
MAINT on AIS Activation –
TX SW Priority – –
IDU/Ether Signal Port Setting – –
Status/Setup FE Link Down – –
IDU/Sub Signal SC4 –
Status/Setup SC5 –
IDU/PMC NE Name – –
Note –
Aux I/O Input Name –
Input Condition –
Input Status Strings –
Output Name –
Output Control –
PMON PMON Threshold –
PMON All Data Reset – –
Save to disk –
Logging Save to disk –
PMC Date/Time – –
PMC Reset – –
Download Configuration File – – – –
Update – – – –
Download Program File – – – –
Upload Configuration File – – – –
LAN Reset – –
*Admin: Enabled to access all Network Elements.
*Remote: Enabled to access all Network Elements.
(Disabled from changing network configuration and changing/downloading programs)
*Local: Enabled to access Local and Opposite NE.
(Disabled from changing network configuration and changing/downloading programs)
*User: Enabled to access items insofar as the equipment is not affected.
*Monitor: Enabled to monitor only and disabled from control functions.
-9-
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.4 Shutting Down PNMT
To exit the PNMT application:
1. Click System Exit on the menu bar of the main window
- 10 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.5 Searching for and Connecting to Selected Network Elements
The summary description of the current network element (Network Element Name, Equipment
Type, Opposite Network Element, etc.), where PNMT is connected, is displayed with this function.
Summary description of the opposite network element belonging to that link is also displayed.
To search for, or connect to, a Network Element in the network:
1. Click System Connect… on menu bar of PNMT main window.
NOTE
Initially, only the current NE physically connected to the
PNMT and its opposite NE counterpart will be shown on
the Network Element List.
2. Click icon in the tool bar or List Search for Network Element in the menu bar on
the Network Element List window to display all connectable Network Elements in the
network.
3. Select and highlight the network element to be viewed.
4. Click icon in the tool bar or List Connect to Network Element in the menu bar on
the network element List window. The PNMT main window of the selected network
element and its opposite NE counterpart will be displayed.
- 11 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.6 Change Password
To change the password:
1. Click System Change Password on the menu bar on main window.
NOTE
For details on initial user name and password, please refer
to PNMT Installation manual.
- 12 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.7 Alarm Buzzer Setting
This function is used to activate and set the Alarm Buzzer. The desired sound scheme can also be
set using this function.
To set the Alarm Buzzer:
1. Click System Alarm Buzzer in the main window.
2. Select the Wave file box to activate the buzzer. No sound is the initial factory setting of
the PNMT.
3. Enter the location of the sound file (*.wav) Otherwise; click […] to locate the desired file.
You can also preview the *.wav file by clicking on the arrow next to the browse button.
4. Click [OK] or [Apply] to activate the new setting.
NOTE
When the text column is a blank, it is possible to set it. In
this case, the buzzer sound does not ring even though the
buzzer stop function is enabled.
- 13 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.8 Refresh
This function is supported only by PNMT. This function enables PNMT to acquire all status data
manually and to update equipment information
To Refresh:
1. Click Refresh Refresh in the main window or click on the refresh icon in the tool bar.
NOTE
Metered items such as TX power, RX level, power supply
and BER are automatically refreshed every 15 seconds.
This function is used when the immediate refresh of these
metered items is necessary or when immediate
confirmation of all current status information is required.
- 14 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.9 Remote Viewing PNMT main window
You can view a target link within one CPMC cluster of the Pasolink network by searching through
the connected NE’s and then connecting to a target NE. Please refer to Section 2.5 Searching for
and Connecting to Selected Network Elements. This function allows remote connection to any
NE in the network.
NOTE: For multi-CPMC network, you can only connect to NE’s that are being polled by the same
CPMC as the local NE to which you are directly connected – via the PNMT cable.
- 15 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.10 License
To protect PNMT functions, the PNMT application includes license files.
To display the current license status,
1. Click Help License… in the main window.
- 16 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.11 Overall Tab
This tab is displayed at startup. The overall tab provides an overall snapshot of the most significant
monitored items of the NE.
1+1 (Hot Standby) Overall window 1+1 (Twin Path) Overall window
- 17 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.12 ODU Tab
This function is used to display the values and status of the monitored items of the ODU.
To view the alarm and status display of the ODU:
1. Click ODU tab in PNMT main window of the target NE.
- 18 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
Monitored Items
TX PORTION RX PORTION
Alarm Alarm
IF INPUT - Monitor IF signal Input. RX LEVEL - Monitor RX Level. Item/Status
Item/Status area is shown with transparent area is shown with transparent letters and gray
letters and gray background in case of CPU background in case of CPU Alarm or IDU-ODU
Alarm or IDU-ODU LINK Alarm. LINK Alarm.
TX POWER - Monitor TX Power. RX APC - Monitors the Automatic Phase
Item/Status area is shown with transparent Control unit. Item/Status field is shown with
letters and gray background in case of CPU transparent letters and gray background in case of
Alarm or IDU-ODU LINK Alarm. CPU Alarm or IDU-ODU LINK Alarm.
TX APC - Monitors the Automatic Phase
Control unit. Item/Status area is shown with Monitoring
transparent letters and gray background in RX Level - Display RX Level value in volt and
case of CPU Alarm or IDU-ODU LINK dBm. Item and status fields are shown and item
Alarm. field uses black fonts and status indicates no
information in case of CPU Alarm or IDU-ODU
Status/Monitoring LINK Alarm.
MTPC TX Power - the current value (in dB)
of the internal attenuation set in ODU. Item COMMON PORTION
and status areas are shown and item area uses Alarm
black font and status indicates no information IDU-ODU LINK – the failure of connection
in case of TX Power Control is ATPC or CPU between IDU and ODU. Item/Status fields is
Alarm or IDU-ODU LINK Alarm. shown with transparent letters and gray
TX Power – the transmitting power of the background in case of CPU Alarm.
ODU in volt and dBm. Item and status area are
shown and item area uses black font and status Status/Monitoring
indicates no information in case of CPU Alarm ODU Type - the type of ODU connecting with
or IDU-ODU LINK Alarm. the equipment. Item and status fields are shown
and item field uses black fonts and status
indicates no information in case of CPU Alarm or
IDU-ODU LINK Alarm.
- 19 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.13 IDU Tab
2.13.1 IDU Tab
To view the alarm and status of the IDU:
1. Select the IDU tab in PNMT window of the target NE.
- 20 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
Alarm
TX PORTION INPUT: Item and status fields are not
Alarm displayed when system has no WS
MOD: Monitor Modulator portion. Interface.
Item/Status field is shown with transparent BP OUTPUT: Item and status fields are
letters and gray background in case of CPU not displayed when system has no WS
Alarm. Interface.
TX CLK LOSS: Item/Status field is Usage Error: Item and status fields are not
shown with transparent letters and gray displayed when system has no WS
background in case of CPU Alarm. Interface. Status has no information in case
RX PORTION Channel Usage Error shows Report.
Alarm Status
DEM : Monitor Demodulator. Item/Status AIS SEND: Item and status fields are not
field is shown with transparent letters and displayed when system has no WS
gray background in case of CPU Alarm. Interface i.
LOW BER: Item/Status field is shown AIS RCVD: Item and status fields are not
with transparent letters and gray displayed when system has no WS
background in case of CPU Alarm. Interface. Status indicates no information in
HIGH BER: Item/Status field is shown case WS AIS RCVD shows Not Report.
with transparent letters and gray Usage: Alarm inhibit state of the WS.
background in case of CPU Alarm. Channels (CH)
BER ALARM: Item/Status field is shown Alarm
with transparent letters and gray INPUT: Status indicates no information in
background in case of CPU Alarm. case Main LAN utilizes this band.
FRAME ASYNC: Item/Status field is BP OUTPUT: Status is no information in
shown with transparent letters and gray case Main LAN uses this band.
- 21 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
background in case of CPU Alarm. Usage Error: Status is no information in
RX CLK LOSS: Item/Status field is case Channel Usage Error is Report.
shown with transparent letters and gray Status
background in case of CPU Alarm. AIS SEND: Status indicates no information
in case Main LAN uses this band.
COMMON PORTION AIS RCVD: Status indicates no
Alarm information in case Main LAN uses this
IDU-ODU LINK: Item/Status field is band or AIS RCVD shows Not Report.
shown with transparent letters and gray LB1: Near-end Loopback status: Status
background in case of CPU Alarm. indicates no information in case Main LAN
CPU: uses this band.
No.1 No.2 COMMON LB2: Custom Loopback status: Status has
Alarm no information in case Main LAN uses this
LAN INTFC: Item and status fields are band.
shown and item field uses black font and Usage: Alarm inhibit state of the channel.
status indicates no information when the Status indicates no information in case
system has no Main LAN Interface. Main LAN uses this band.
Link (Port1/Port2): Item and status fields
are shown and item field uses black font
and status indicates no information when
the system has no Main LAN Interface.
Collision (Port1/Port2) : Item and status
fields are shown and item field uses black
font and status indicates no information
when the system has no Main LAN
Interface or when Collision shows Not
Report for Port Setting where a Main LAN
Interface is available.
Status
AIS SEND Report
- 22 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.13.2 Loopback
To set the loopback:
1. Click the target channel in IDU window.
2. Select LB1 or LB2 Tab in ensuing window.
3. These are available when Usage is enabled on the channel. Select ON to activate the
loopback or OFF to remove the loopback.
NOTE
First, switch ON maintenance mode before executing the
loopback.
- 23 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.13.3 Channel Usage
- 24 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.13.4 AIS RCVD Report
(a) For Traffic channel
1. This function is available for each channel. Click
CH for the selected channel in IDU window.
2. Select AIS RCVD Tab window.
3. Select Report to generate the alarm for AIS RCVD
of the channel. Or set it Not Report to inhibit the
AIS RCVD alarm.
4. Click [Execute] to activate.
5. Click [Close] when finished.
- 25 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.14 Auxiliary I/O Tab
4-relay outputs and 6 photocoupler inputs are provided in IDU for external control and alarms. The
setting for each relay output/photocoupler input is enabled by clicking on selected device in
Auxiliary I/O Monitor window.
To monitor and set the Auxiliary I/O:
1. Select the Aux. I/O tab in PNMT window
2. Enter the designation of the selected input in the Name field. A maximum of 32
characters can be used.
3. Select the desired input condition in the Condition section. You can select from the
following three (3) choices: the alarm is reported when Event ON (closed loop for
selected input terminal) or the alarm is reported when Event OFF (the selected input
terminal is open) or the just Status information is reported instead of the alarm.
- 26 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
4. Enter the status strings corresponding to the input condition in the Event ON and Event
OFF field in the Status Strings section. A maximum of 32 characters can be used.
5. Click [Execute] to activate the selected state of the device.
6. Click [Close] when finished.
2. Enter the desired designation (name) of the selected output in the Name field. A
maximum of 32 characters can be used.
3. To select the desired output condition for the selected relay output, select the Event ON
(closed loop for output terminal) or Event OFF (the output terminal will be open) buttons
in the Control section.
4. Enter the desired status strings for the selected relay output in the appropriate Event ON
(closed loop for output terminal) and Event OFF (the output terminal will be open) fields
on the Control section. A maximum of 32 characters can be entered.
5. Click [Execute] to carry out the command.
6. Click [Close] when finished.
- 27 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.15 PM CARD Monitor
2.15.1 PM CARD Monitor
Select the PMC tab in PNMT main window of the target NE.
The following items can be monitored and controlled in PMC tab:
• PMC-ALM CONT LINK: The alarm indicates the
communication state between PM CARD and IDU.
• Date/Time
• PMC Reset
• LAN Reset
• Download Configuration File
• Download Program File
• Download Equipment Configuration File
• Upload Configuration File
• Upload Equipment Configuration File
NOTE
To set the values of the Date and Time fields to the same
value as the PNMT computer, check the Display PC Time
box.
- 28 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
1-2) To set the Date and Time on PM Card:
1) Select Set Date/Time in Date/Time window.
2) Click [Execute].
3) Click [Close] when finished.
NOTE
Resetting the PMC will not affect the traffic. The
connection to the selected NE will be disrupted for a few
minutes but will automatically be restored.
NOTE
First switch maintenance mode ON before executing
PMC Reset.
4. Click [Close] when finished.
NOTE
Resetting the LAN will affect the traffic. The connection
to the selected NE will be disrupted for a few minutes but
will be automatically restored.
To reset the Main Interface LAN Port:
1. LAN Reset function is enabled where a Main LAN Interface
is available. Click [LAN Reset] in PMC tab.
2. Select the port (Port1 or Port2), which needs to be reset.
3. Click [Execute] to continue the LAN reset operation.
NOTE
Switch ON maintenance mode first before executing LAN
Reset.
4. Click [Close] when finished.
- 29 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.15.5 Downloading the Configuration Files to the PMC
This function is for download configuration files from the PNMT to the PM card. The
configuration file - system.cfg, contains the IP addresses of the PM card as well as the opposite
station. A network.cfg file contains information about the PASOLINK network where the PM card
is located.
To download new configuration file to the PM card:
1. Click [Configuration File] in PMC tab’s Download (PC>>PMC) section.
WARNING!!!
Make sure that the correct configuration file is
downloaded to the correct PM card. Incorrect
configuration files can cause PM card or network failure.
4. Click [Execute] to start the operation.
NOTE
Switch ON maintenance mode first then execute the
Download Configuration File.
5. A message window indicating the status of the operation will appear. It will close
automatically once the operation is finished.
WARNING!!!
Make sure that you have successfully downloaded the
configuration file before attempting an Update.
Otherwise the PM Card will switch to an empty ROM
that may cause PM Card failure.
6. Click [Update] to activate the new configuration file(s).
7. Select the appropriate box for the type of configuration file that will be updated. One or
more configuration file can be updated by checking the box opposite to the configuration
file name. Click [Execute] to start the operation. The "with ROM (PMC Program)
Switching" box is for switching to the ROM with the new PMC Program and has the same
function that will be discussed in next section.
- 30 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
NOTE
When updating system.cfg file, PMC to PMC
communication will be lost when the PMC re-
initializes to the new system configuration. This
WILL NOT affect the radio link. During this time
PNMT connection to the PASOLINK will be
disrupted but it will automatically be restored
after the PMC resets.
NOTE
Updating the PMC will not affect the traffic. PNMT to the
selected Pasolink connection will be disrupted for a few
minutes but will be automatically re-stored.
8. Click [Close] when done
2. Enter the appropriate location of the program file (*.pof) in File field. Otherwise, click
[Browse] to locate the file.
WARNING!!!
Make sure that the correct program file is downloaded to
the PM card. Incorrect program files may cause PM card
failure.
NOTE
Switch ON maintenance mode first before executing
Download Program File.
- 31 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
4. A message window will appear displaying the status of the operation; it will close
automatically once the download is completed.
NOTE
This operation may take several minutes depending on
the program file size.
NOTE
The connection from the PNMT to the selected Pasolink
will be disrupted a few minutes but will automatically be
restored.
8. Click [Close] when done.
- 32 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.15.8 Downloading Equipment Configuration Files to the Equipment
This function is used to download equipment configuration files from PNMS/PNMT to PMC. An
equipment configuration file contains radio configuration data (i.e. frequency, main interface).
To download new equipment configuration file to equipment:
1. Click [Equipment Config File] in PMC tab’s Download (PC>>PMC) section.
WARNING!!!
Make sure that the correct configuration file is downloaded to
PMC. Incorrect configuration file may lead to PMC failure or
traffic disconnection.
3. Click [Execute] to start operation.
4. A message window indicating warning will appear. To confirm click on [OK] button.
5. Click [Close].
- 33 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.15.9 Uploading Equipment Configuration File to PNMS/PNMT PC
This function is used to upload equipment configuration file from PMC to PNMS/PNMT
PCPASOLINK.
To upload configuration file from equipment:
1. Click [Equipment Config File] in PMC tab’s Upload (PMC>>PC) section.
- 34 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.16 Maintenance
There are ten maintenance control items that can be executed with the maintenance menu. The
function of each control is as follows.
MAINT: To switch Maintenance mode ON
TX Mute: To turn off TX power
CW (MOD Carrier): To turn on Continuous Wave for measurements
BER ALM >> AIS: Bit Error Rate Alarm Indication Signal
ATPC Manual: To enable the optional setting of the manual transmitting power
when the ATPC is in operation.
TX Switch: To switch the current system you want to use for signal
transmission manually.
RX Switch: To switch the current system you want to use for signal reception.
*These windows are not available when MAINT is OFF. (Switch to Maintenance mode first
message is displayed.)
- 35 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
NOTE
When the Maintenance mode is to be turned OFF, make
sure that all items/functions controlled in maintenance
mode i are turned OFF first. Otherwise, it is not possible
to turn OFF the maintenance mode.
- 36 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.16.3 Selecting TX Mute Status
TX power of the ODU is switched off when TX Mute is ON. This should be OFF in normal
operation.
To change the TX Mute status:
1. TX Mute function is available for any directly connected via cable with the PNMT. The
control screen does not open; moreover, control functions are not available for any NE that
are wireless opposite counterparts or connected remotely by search. Click [TX Mute] in
Maintenance window.
NOTE
Switch ON maintenance mode first
before executing TX Mute.
2. Select ON/OFF depending on the desired state. When TX Mute status is ON, the status
column covered with yellow color.
3. Click [Execute] to carry out the command.
CAUTION
A message will appear, indicating that when TX mute is
ON, the wireless link connection will be affected. The
connection to the opposite Pasolink will be disrupted for a
few minutes.
4. Click [Close] when finished.
NOTE
Switch ON maintenance mode first
before executing CW.
2. Select ON/OFF button depending on desired. When CW status is ON, the status column
appears in yellow.
3. Click [Execute] to carry out command.
- 37 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
CAUTION
A message will appear, warning that when CW is turned
ON the wireless link connection will be affected. The
connection to the opposite Pasolink will be disrupted for a
few minutes.
4. Click [Close] when finished.
NOTE
Switch ON maintenance mode first before
executing BER ALM >> AIS. It is available to
set this function regardless of the
Maintenance status when MAINT on AIS
Activation status is disabled.
2. Select ON/OFF button depending on the desired state. When BER ALM >> AIS status is
OFF, the status column is displayed in yellow.
3. Click [Execute] to carry out command.
4. Click [Close] when finished.
NOTE
Switch ON maintenance mode first
before executing ATPC Manual.
2. Select manually turning ON or OFF the ATPC manual and the ATPC manual power that
will be transmitted in dB. When ATPC Manual status is ON, the status column appears in
yellow.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 38 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.16.7 TX Switch (For 1+1 Hot Standby system only)
To switchover to the other system in 1+1 configuration:
1. TX Switch function is only available when 1+1 Hot Standby system. There is no field
displayed in case 1+0 or 1+0 Expandable. Item and status fields are shown and the item
field uses transparent letters, status indicates no information in case of 1+1 Twin Path.
Click [TX Switch] in Maintenance window
NOTE
Switch ON maintenance mode first
before executing TX Switch.
2. Select either manually TX to No. 1 or No.2 or allow the PASOLINK to Auto TX Switch.
The TX Switch is normally set on Auto. When TX Switch status is No.1 or No.2 (except
Auto), the status column appears in yellow.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
NOTE
Switch ON maintenance mode first
before executing RX Switch.
2. Select either manual switching of RX to No. 1 or No.2 or allow the PASOLINK to Auto
RX Switch to be executed. The RX Switch is normally set on Auto. When TX Switch
status is No.1 or No.2 (except Auto), the status column appears in yellow.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 39 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17 Equipment Setup
Main signal, Wayside signal, Service signal, ODU and PM card portion can be monitored and
controlled in this window.
- 40 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
- 41 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
- 42 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.2 Setting the Frequency Plan
To setup the frequency plan:
1. Click [Frequency Plan] in Equipment Setup
window.
2. On Frequency Plan window, only the TX/RX
CH is configurable. The rest of the items appear
shaded in gray on the screen and are automatically
set according to the allocated channel in TX/RX
CH.
NOTE: These parameter columns except TX/RX
CH black fonts against a colored background
3. According to the allocated channel in TX/RX CH.
4. Click [Execute] to activate the new set of values.
CAUTION
A message will appear, warning that changing
the TX channel will affect the wireless link
connection.
- 43 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.4 Setting the Bit Rate
NOTE:
Bit Rate can be selected only for Bit Rate Free-type PASOLINK.
In this window the operating bit-rate of the System is set.. The inventory operating mode or
the ODU Capacity is shown in the ODU block of the Equipment setup window. The total
operating bit-rate is always within the ODU transmission capacity.
Changing the Bit Rate of the opposite wireless counterpart may have an effect on Custom
Loop back (LB2) status of the local wireless network element. In case this occurs, cancel
(turn off) the state of LB2 manually. The procedure for LB2 is shown in section 2.13.2.
To set the Bit Rate value:
1. Click [Bit Rate] in Equipment Setup window.
2. Select the bit rate value by clicking on appropriate bit rate button displayed in Bit Rate
window.
NOTE
Some bit rate buttons may not be selectable -depending
on the type of IDU used.
CAUTION
A message will appear, warning that changing the Bit
Rate will affect the wireless link connection.
4. Click [Close] when finished.
- 44 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.6 Setting the BER Threshold
To set the BER Threshold:
1. Click [BER Threshold] in Equipment Setup window.
2. Select the desired value of the BER Threshold.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 45 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.10 Setting the ATPC RX Threshold
To set ATPC RX Threshold:
1. ATPC RX Threshold function is
available for ODU Version 4. Item
and status fields are shown and the
item field uses transparent letters,
status indicates no information in case
of ODU Version 3. Click [ATPC RX
Threshold] in Equipment Setup
window.
2. Set the RX Threshold value from -80dB to -30dB when using the ATPC system.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 46 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.13 Setting the ODU ALM Mode
This function controls ATPC power to set value (MAX/MIN/Hold) when max power control is
continued for more than 90 seconds or Frame ASYNC alarm occurrs and continues for more than
90 seconds.
To set ODU ALM Mode Status:
1. ODU ALM Mode function is available for ODU
Version 4. Item and status fields are shown and the
item field uses transparent letters, status indicates no
information in case ODU Version 3. Click [ODU
ALM Mode] in Equipment Setup window.
2. Set the ODU ALM Mode Status when using the
ATPC system.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 47 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.16 Setting the MAINT on AIS Activation Status
To set the MAINT on AIS Activation Status:
1. Click [MAINT on AIS Activation] in
Equipment Setup window.
2. Select the desired status of the MAINT on
AIS Activation.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
- 48 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.18 Setting the MAIN LAN INTFC
This function enables you to set the 10BASE-T or 2M and its properties. When the 10BASE-T is
available, you can select bandwidth for Port1 and Port2 wherein the sum of bandwidth of Port1 and
Port2 is equal to or less than the bit rate (Port1+Port2 < Bit Rate). Port 2 cannot be set to a larger
throughput than Port 1.
CAUTION
Port1 and Port2 settings have to be reset if the Bit Rate is
changed.
To enable the Port Setting:
There are seven items that can be executed for each port in Port Setting menu. The function of each
control is as follows.
Throughput: This function selects bandwidth for Port1 and Port2. Sum of the bandwidth
of Port1 and Port2 should be less than or equal to the bit rate (Port1+Port2
<= Bit Rate).
Mode: This function corresponds to the LAN interface signal speed and mode.
Flow CTRL: This function is used to restrict the quantity of the packet sent to Switching
Hub so as not to cause buffer overflow hat will lead to dropped packets.
Framing: This function is used to frame the signal in G.704 E1 format.
This means that signal will be framed in 64Kbps timeslots.
CAS: Channel Associated Signaling. If set to ON (1), the LAN signal is
multiplexed to the data channel excluding CAS channel field. This means
that there will be a dedicated in-band signaling channel. If set to OFF (0),
the LAN signal will be multiplexed to the data signal, including the CAS
channel field. In other words, there will be no dedicated channel for in-
band signaling. This function is available if framing is set to ON.
CRC: Cyclic Redundancy Check: The method used to detect the error of received
by adding a CRC-bit to the packet frame. The CRC-bit is then checked at
the receiving side.
Collision: If the LAN is set in half-duplex mode, collision is normally reported (as
event) to the NMS. Collision is not considered an alarm so it is just a status
report. In case, that the collision report is not to be forwarded to the NMS,
this can be masked by setting it to Not Report. This function is available if
framing is set to ON.
- 49 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.19 Setting the FE Link Down Status
When Link fault information is received from an opposite site, release the LAN connection from
the interface. When a Link fault is detected, it sends Link fault information to the opposite site and
also releases the LAN connection. Disable means that Far End Link Down control is not available
To set the FE Link Down status:
1. Click [FE Link Down] in Equipment Setup window.
2. Select the desired status of the FE Link Down window.
3. Click [Execute] to activate the new setting.
4. Click [Close] when finished.
2. Select desired speed and interface to be associated with the service channel.
3. Click [Execute] to activate the new setting
4. Click [Close] when finished.
- 50 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.17.22 Editing the Note for NE
To put an optional description on current NE:
1. Click [Note] in Equipment Setup window.
2. Enter the optional description for the specific NE in
Note dialog box. A maximum of 100 characters can be
used in this field.
3. Click [Execute] when finished.
4. Click [Close] when finished.
- 51 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.18 Link Performance Monitor
The following performance items can be monitored according to the parameters expressed in the
G.826 recommendation:
ES: Errored seconds
SES: Severely errored second
UAS: Unavailable Seconds
BBE: Background Block Error
This window displays each performance item’s value in two kinds of measurement periods: a 15-
minute interval (15 min) and a 24-hour interval (Day). The current (%) value of 15 min and Day in
the left table means the value of counts of ES, SES, UAS and BBE every 15 minutes and per day
(24 hours) as a percentage respectively. Each value is calculated based on the following method.
The background color of each value is the result of the threshold value setting. That is, if
measurement data value exceeds an alarm occurence level, the background color will turn pink,
and will revert to white once the measurement data value is less than the alarm resolution level.
The threshold values can be set in the Threshold window. Moreover, all data can be reset using the
[All Data Reset] button. Detailed daily performance data can be seen by clicking [Detail].
- 52 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
Current (%)
ES, SES, UAS (15 min)
The number (A) of counts for 15 minutes is divided by 900 seconds, which is multiplied with 100
and the result is displayed as a percentage.
A
Value = × 100
900
BBE (Day)
The number (A) of counts through fixed 15 minutes period from 00:00 to 23:45 is divided by total
number of seconds (B) times blocks value where B is 900 seconds * number of 15 minutes blocks.
The value is multiplied with 100 and the result is displayed as a percentage. The value of blocks
depends on the bit rate. Refers to the following table of the relation of blocks value and bit rate.
A
Value = × 100
B × blocks
Note) the maximum B value is 86400(=900*96) seconds.
- 53 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
History 15 min status
The status of each performance item on 15 min of History in table means the existence of threshold
alarm occurrence. The Alarm string in field indicates an occurrence of the performance items
exceeding the threshold alarm occurence level at least in the 15-minute interval data for the past
seven days. In order to change from Alarm to Normal, it is required for the past seven days for
each 15-minute interval data not to exceed a threshold alarm recover level.
- 54 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.18.2 Threshold Setting
To set the threshold values:
1. Click [Threshold (%)]in Summary Link Performance Monitor window
2. Select the performance item that is to be configured in the table shown above. The G.826
measuring parameters become available for setting when selected. The arrow buttons on the
left-hand side of the field indicates this.
3. Set the value when the alarm ocurred (Occur) and when the alarm was resolved (Recover)
in the appropriate field. The measuring parameter will initiate an alarm status indication
when it reaches the alarm occurence (occur) value or an alarm clear status when it reaches
the resolution (recover) value set in threshold table.
4. Click [Execute] to activate the new settings.
5. Click [Close] when finished.
The threshold value used in this table is expressed as a percentage. The alarm recover level must
have a value lower than the alarm occur” level. In case the threshold value you wish to use is in
count form (as shown in the below table), please convert it into percentage first according to the
explanation in the preceding chapter.
Threshold Threshold
Performance Item Expression
(count) (A) (%) (B)
ES,SES,UAS 90 A/900*100=B 10.00
15min A/(900*blocks)*100
BBE (BitRate=2*2MB) 3069 10.00
(Blocks=341)
ES,SES,UAS 8640 A/86400*100=B 10.00
1Day BBE A/(86400*blocks)*100
2946240 10.00
(BitRate=2*2MB) (Blocks=341)
Threshold value Conversion
- 55 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.18.3 Link Performance Monitor (Daily Data) window
This window contains the 24-hour performance data for the current 8 days.
To view the Link Performance Monitor (Daily Data) window:
1. Click [Detail] in Link Performance Monitor window.
- 56 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.18.4 Link Performance Monitor (15-min Data) window
To view the 15-min data of the desired date:
1. Click of the target date in Link Performance Monitor (15-min Data) window to display the
detailed 15-min performance data.
Reload
Save
2. The data can be saved in text format by clicking then save icon. It can be refreshed by
clicking the refresh button.
- 57 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.18.5 All Data Reset
1. Click [All Data Reset] in Summary Link Performance Monitor window.
WARNING!!!
Make sure that the current data has been
saved. This operation will delete all the
performance data of the current week.
- 58 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.19 NE Stored Log
The NE Stored Log window displays the date when the event or command was received, the
equipment, item, and status.
- 59 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.20 Version Tab
The inventory information of the PM card, ODU and IDU can be viewed using this function.
- 60 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
2.21 License import
2.21.1 License import
To update the license file:
1. Go to Help License in the menu bar on PNMT main window.
- 61 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
3. Click […] to locate the new license key file.
4. Indicate the License key file (i.e. License.key) for the PNMT. Select the License key
file and click [Open] to continue.
- 62 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
5. After verifying that the path to License key file is correct, click [Next] to proceed.
6. The progress of checking the license file will be displayed. If no error is encountered
during checking the license file, click [Next] when the button becomes available.
- 63 -
Submission Prohibited ROI-S05592
NEC Internal Use Only
7. Verify the contents of the license you are applying for.
- 64 -