Drain Design
Drain Design
Drain Design
Input
From Iso-Pluvial diagram of Raichur area (subzone-3h)
max rainfall data for 24hr in 100 year= 160 mm (Ref Annex-1, Page no-)
Converting this 100year 24hr rainfall for 2year return period 24hr rainfall
= 160X0.39 = 62.4 mm (Ref Annex-1,
page no- for coeff. Taken from SP42)
Converting this 24hr rainfall into 1hr rainfall=
= 62.4X0.39 = 24.336 mm/hr (Ref Annex-1,
page no- for coeff. Taken from SP42)
Time of concentration (Tc) calculation
Farthest point from drain L = 400 m
Slop conidered s = 1/250
Therfore Tc = .02x(L)^0.77X(S)^-.383
= 16.7 Min
considering 15min for ease in calculation
rainfall intensity corresponding to 15 min = 2.4 X 24.336 (Ref Annex-1, page no-
= 58.4 mm/hr for coeff. Taken from SP42)
Total
/Cummul
ative Hydraulic Mannigs Drain Flow Excavatio Pipe
Drain Section Discharge Bed Slope Flow Section Perimeter Area Radius coe No of pipes Capacity Remarks n backfill length
Avg Width Avg Depth
Q B (B) (D) P A R=A/P n n1 Qc
xR^0.67xS^
CuM m M M M SqM M 0.5
D1 0.10 0.10 400 0.25 0.79 0.049063 0.0625 0.01 3 0.11 OK 158.24 145.5819 258
D2 0.13 0.23 450 0.45 0.7 1.85 0.315 0.17027 0.015 0.30 OK 199.75
D4 0.05 0.05 200 0.3 0.3 0.90 0.09 0.1 0.015 0.09 OK 61.95
D4a 0.05 0.05 200 0.25 0.79 0.049063 0.0625 0.01 2 0.11 OK 6
D4b 0.05 0.05 200 0.3 0.3 0.90 0.09 0.1 0.015 0.09 OK 10
D3 0.05 0.12 200 0.3 0.4 1.10 0.12 0.109091 0.015 0.13 OK 75
D5 0.10 0.10 200 0.3 0.4 1.10 0.12 0.109091 0.015 0.13 OK 58.5 7 16
D6 0.06 0.06 150 0.3 0.3 0.90 0.09 0.1 0.015 0.10 OK 40
D7 0.13 0.13 400 0.3 0.7 1.70 0.21 0.123529 0.015 0.17 OK 570 180
D7a 0.13 0.13 400 0.4 1.26 0.1256 0.1 0.01 1 0.13 OK 1179.44 360
16