Concrete Canvas Material Data Post Set CC Properties: Strength

The document provides technical specifications for Concrete Canvas, a concrete impregnated fabric material. It details the physical and mechanical properties of different CC thicknesses, including compressive strength, tensile strength, abrasion resistance, puncture resistance, and more. It also outlines the pre-set and post-set properties and testing certifications for CC.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views

Concrete Canvas Material Data Post Set CC Properties: Strength

The document provides technical specifications for Concrete Canvas, a concrete impregnated fabric material. It details the physical and mechanical properties of different CC thicknesses, including compressive strength, tensile strength, abrasion resistance, puncture resistance, and more. It also outlines the pre-set and post-set properties and testing certifications for CC.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TM

For further information or technical support contact:

+ 44 (0) 845 680 1908 [email protected] www www.concretecanvas.co.uk


Concrete Impregnated Fabric...

Concrete Canvas™ Material Data Post Set CC Properties


Post set data is based on CC hydrated in accordance with the CC
Hydration Guide.
Strength
Very high early strength is a fundamental characteristic of CC.
Typical strengths and physical characteristics are as follows:

Compressive tests based on ASTM C109 – 02


- 10 day compressive failure stress (MPa) 40

Bending tests based on BS EN 12467:2004


CC Physical Properties* - 10 day bending failure stress (MPa) 3.4
- 10 day bending Youngs modulus (MPa) 180
CC Thickness Batch Roll Bulk Roll Roll Width
(mm) Size (sqm) Size (sqm) (m) Tensile data (Initial crack)
CC5 5 10 200 1.0 Tensile strength (kN/m)
CC8 8 5 125 1.1 Length direction Width direction
CC13 13 N/A 80 1.1 CC5 6.7 3.8
CC8 8.6 6.6
CC Mass (unset) Density (unset) Density (set)
(kg/m2) (kg/m3) (kg/m3) CC13 19.5 12.8
CC5 7.0 1500 +30-35% Abrasion Resistance (DIN 52108)
CC8 12.0 1500 +30-35% - Similar to twice that of OPC Max 0.10 gm/cm2
CC13 19.0 1500 +30-35% 4-5
MOHS hardness

Pre-Set CC Properties CBR Puncture Resistance EN ISO 12236: 2007 (CC8 & CC13 only)
- Min. Push-through force 2.69kN
Setting - Max. Deflection at Peak 38mm
Working Time 1-2 hours subject to ambient temperature
Resistance to Imposed Loads on Vehicle Traffic Areas
CC will achieve 80% strength at 24 hours after hydration. EN 1991-1-1:2002 (CC8 & CC13 only)
- Category G compliant
Method of Hydration
- Gross weight of 2 axle vehicle 30 to 160kN
Spray the fibre surface with water until it feels wet to touch - Uniformly distributed load not exceeding 5kN/sqm
for several minutes after spraying.
Standard Test Method for Impact Resistance of Pipeline Coatings
Re-spray the CC again after 1 hour if: ASTM G13 (CC13 only) Passed
- Installing CC5
Other
- Installing CC on a steep or vertical surface
- Installing in warm climates Freeze-thaw testing (BS EN 12467:2004 part 5.5.2) Passed

Notes: Soak-Dry testing (BS EN 12467:2004 part 5.5.5) Passed


- CC cannot be over hydrated and an excess of water is always
recommended. Water impermeability (BS EN 12467:2004 part 5.4.4) Passed**
- Minimum ratio of water:CC is 1:2 by weight.
- Do not jet high pressure water directly onto the CC as this may wash Reaction to Fire
a channel in the material. CC has achieved Euroclass B certification:
- CC can be hydrated using saline or non-saline water. BS EN 13501-1:2007+A1:2009 B-s1, d0
- CC will hydrate and set underwater.
- CC has a working time of 1-2 hours after hydration. Do not move CC CC Patent Information
once it has begun to set.
Patent Protected
- Working time will be reduced in hot climates. Pat Pend/Granted: AE (932/2006), AU (2005254788),
- CC will set hard in 24 hours but will continue to gain strength for BR (PI 0511408-0), CA (2570532), CA (2655054), EP (1766162),
years. EP (2027319), GB (2455008), IN (20/DELNP/2007),
JP (2007-516049), NO (20070245), RU (2386767), SA (12/303,864),
- If CC is not fully saturated, the set may be delayed and strength US (7721749), US (US-2010-0233417-A1), WO 2010/086618, ZA Concrete Canvas Ltd.
reduced. If the set is delayed, re-wet with a large excess of water. (2007/0471), ZA (2009/00222) and other patents pending. CF37 5SP, United Kingdom
11
* Indicative values
EN12467:2004
** For containment applications where a 100% waterproof seal is required, Concrete Canvas:

Contact Concrete Canvas UK


Fibre cement sheet
it is recommended to use CC as a protective overlay in combination with NT
an appropriate sealed membrane liner. CC is not recommended as the sole Oversize sheets
barrier layer where 100% impermeability is critical.
Address E-mail: [email protected] Class 1, Category A
Reaction to Fire B-s1,d0
Unit 3, Block A22, Phone: +44 (0) 845 680 1908
Treforest Ind. Estate, Web: www.concretecanvas.co.uk The information contained herein is offered free of charge and is, to the best of our knowledge, accurate. However, since
the circumstances and conditions in which such information and the products discussed therein can be used may vary and
CF37 5SP, UK are beyond our control, we make no warranty, express or implied, of merchantability, fitness or otherwise, or against patent
infringement, and we accept no liability, with respect to or arising from use of such information or any such product.

© Concrete Canvas Ltd 2012