Enidine Wire Rope Isolators

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

CWR-coverNEW/RED 11/20/02 2:42 PM Page 2

Enidine Wire Rope Isolators

Wire Rope Isolators

Solutions in Energy Absorption and Vibration Isolation.


CWR-coverNEW/RED 11/20/02 2:42 PM Page 3

Typical WireWire
Introducing RopeRope
Isolator Applications
Isolators
Electronic
Enclosures

Medi-vac
Equipment Radar Systems

Power Units

Mobile Electronic
Equipment Other Wire Rope Isolator Applications
• Avionics
• Carts, Transporters & Gurneys
• Chemical Processing Equipment
• Chimneys, Scrubbers & Vessels
• Electronic Cabinets
• Military Equipment
• Navigation Equipment
• Over-the-road Transport
• Power Plant Piping Suspension
• Pump, Generator & Compressor Isolation
• Seismic Isolation
• Shipboard Electronics
• Shipping Cases, Skids & Containers
• Transportable Shelters
CWR-coverNEW/RED 11/20/02 2:42 PM Page 5

Enidine WireWire
Introducing Rope Isolators
Rope Isolators

E nidine, a preferred source for energy absorption


and vibration isolation solutions, offers a full
range of Wire Rope and Compact Wire Rope Isolator
products, each designed to reduce the harmful effects
of shock and vibration.

Wire Rope Isolators

Wire Rope Isolators are comprised of stainless steel


stranded cable, threaded through aluminum alloy
retaining bars, crimped and mounted for effective
vibration isolation. With their corrosion resistant,
all-metal construction, Enidine Wire Rope Isolators
are environmentally stable, high-performance
shock and vibration isolators that are unaffected
by temperature extremes, chemicals, oils, ozone
and abrasives.

Featuring a patented crimping pattern, versatile


mounting options and a variety of sizes, these
helical isolator products can help ensure that U.S. Patents 5,549,285
6,290,217
your systems can effectively meet performance 6,244,579
requirements in commercial, industrial, and defense
industries, including MIL-STD-810, MIL-STD-167,
MIL-S-901, MIL-E-5400, STANAG-042, BV43-44 and Load Axis Mounting Orientations
DEF-STND 0755. For more information, please refer to our
“Wire Rope Isolator Selection Guide” on pages 2-3
to assist in selecting a model for your application.

Compact Wire Rope Isolators

For the best in vibration isolation capabilities, choose


Enidine’s Compact Wire Rope Isolators. Smaller than COMPRESSION 45˚COMPRESSION/ROLL
traditional wire ropes, these unique isolators provide
cost-effective, simultaneous shock and vibration
attenuation where package space is at a premium.

Enidine Compact Wire Rope Isolators feature an easy,


single-point installation, which allows them to be installed
in virtually any application. Their small size also permits FIXED SHEAR FIXED ROLL
the isolation of individual system components, making (for Wire Rope Isolators)
them ideal for use in sensitive equipment and electronics.
Just as with our standard Enidine Wire Rope Isolators,
Enidine Compact Wire Rope Isolators feature a patented, all-metal design and components that ensure
maximum reliability, regardless of temperature or substrate requirement, and that can help meet MILSPECS
similar to those of our Wire Rope Isolator series. Please refer to our “Compact Wire Rope Isolator Selection
Guide” on pages 32-33 for more information.

If your application is outside the standard Compact Wire Rope Isolator product range, please consult the
standard Wire Rope Isolator portions of this catalog. If a standard solution is still not available, Enidine
engineers can design an isolator to suit your specifications.

For further information on Enidine Wire Rope and Compact Wire Rope Isolator products, technical
assistance and pricing, please contact Enidine or your nearest authorized distributor. A list of Enidine
distributors can be found by visiting our website at www.enidine.com.

Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 1


CWR-coverNEW/RED 11/20/02 2:42 PM Page 6

Selecting An Enidine Wire Rope Isolator


SIZING INSTRUCTIONS - VIBRATION ISOLATION SIZING INSTRUCTIONS - SHOCK ISOLATION
If the desired system natural frequency is known, refer to the appropriate Selecting appropriate isolators for shock is based on the Wire Rope Isolator’s
Load vs. Natural Frequency curves to determine the recommended Wire average stiffness at the required dynamic deflection (Dmin). Follow the steps
Rope Isolator model. If the preferred system natural frequency is unknown, below to achieve a recommended Wire Rope Isolator selection.
follow the steps below to achieve a recommended Wire Rope Isolator selection.
STEP 1: Fill out Part I and Part III of the Application Worksheet.
STEP 1: Fill out Part I and Part II of the Application Worksheet.
STEP 2: Refer to the Load vs. Deflection curves for the desired loading
STEP 2: Refer to the Load vs. Natural Frequency curves for the required orientation. Locate curves capable of the Minimum Dynamic
loading orientation. Use the System Natural Frequency (ƒn ) Deflection (Dmin) calculated from the worksheet. Find a curve that
calculated from the worksheet to select the smallest Wire Rope is on or slightly under the Average Force (Favg) at the Average
Isolator model capable of the static load (W).
Deflection (davg) calculated from the worksheet.
STEP 3: Specify the required mounting option suffix to complete the part
number. (Please refer to available mounting options as indicated on STEP 3: Specify the required mounting option suffix to complete the part
each Wire Rope Isolator series data page.) number. (Please refer to available mounting options as indicated on
each Wire Rope Isolator series data page.)

APPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC


IMPERIAL METRIC
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________

3. Static Load per Isolator (W): W = WnT W = ________ lbs.* W = ________ N*


* Assumes a central CG
4. Load Axis: Compression Load Axis Load Axis
Shear or Roll
45º Compression/Roll ____________________ ___________________

PART II: VIBRATION SIZING:


1. Input Excitation Frequency (ƒi) = ________ Hz ( = rpm
60
)
ƒi
2. System Natural Frequency for 80% isolation: ƒn = ƒn = ________ Hz* ƒn = ________ Hz*
3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.
The published natural frequencies are based on a 1G input condition.
Random Vibration inputs: Consult Enidine for recommendations.

PART III: SHOCK SIZING:


1. Maximum Allowable Transmitted G Load: (GT): ________G’s
2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2

a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2


V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input: A0 = Peak Acceleration (G’s)
t0 = Duration (seconds)
V = 2 g A0 t0
π

Imperial Metric
2 2
V V
3. Min. Response Deflection: Dmin = Dmin = Dmin = ________in. Dmin = ________mm
g (GT – 1) g (GT – 1) 1000

2 2
4. Average Force: Favg = WV Favg WV Favg = ________lbs. Favg = ________N
=
2g Dmin 2g ( Dmin ) 1000

davg = Dmin davg = ________in. davg = ________mm


5. Average Deflection:
2

Ordering Information
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).
EXAMPLE:
20 WR8 – 600-08 – * – [ ]
1. Select Quantity 2. WR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
Specify Model Number
**Please refer to available mounting options as indicated on each WR series data page.
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.

2 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 7

Selecting An Enidine Wire Rope Isolator


VIBRATION ISOLATION:

A 1,400-lb. pump is rotating at 1,725 rpm, transmitting vibration to adjoining equipment. To control the damaging effects
of unwanted vibration, the pump shall be isolated using four (4) isolators mounted in the compression load axis with
imperial, flat head cap screws. The isolators shall be located symmetrically about the pump’s center of gravity.

Step 1: From Part I and Part II of the Application Worksheet.


WT = 1,400 lbs.
Fi = 1,725 = 28.75 Hz
60
W = 1,400 = 350 lbs. 2,875
Fn = = 9.6 Hz
4 3
Step 2: Referring to the Compression Load vs. Natural Frequency curves for an isolator capable of a maximum
static load of 350 lbs., and a System Natural Frequency of approximately 9.6 Hz, yields a recommended
isolator selection of WR16-206-06.

Step 3: From the Available Mounting Options column, verify that a “B” mounting style is available (for flat head
cap screws in both mount bars). Adding the mounting option suffix to the model number gives the
complete part number of WR16-206-06-B.

SHOCK ISOLATION:

Sensitive electronic equipment weighing 164 lbs. must withstand a 9-inch drop shock when packaged inside of its
shipping container. The electronics shall be suspended inside of the container’s shell using eight (8) isolators (4 per
side) in the roll loading axis. The equipment can withstand a maximum shock response of 15G’s. The isolators shall be
installed symmetrically about the equipment’s center of gravity. Threaded metric holes is the desired mounting option.

Step 1: From Part I and Part III of the Application Worksheet.


V= √ 2(386)(9) = 83.4 inches per second (20.5)(83.4)2
Favg = = 143 lbs.
2(386)(1.29)

Dmin = 83.42 = 1.29 inches davg =


1.29
= .65 inches
386(15 – 1) 2
Step 2: Referring to the Shear/Roll Load vs. Deflection curves for an isolator capable of a maximum deflection of
1.29 inches or greater, and a curve point that is at or slightly below a force of 143 lbs. at .65 inches of
deflection, yields a recommended isolator selection of WR12-506-06.
Step 3: From the Available Mounting Options column, verify that a “D” mounting style is available (for threaded
holes in both mount bars). Adding the mounting option suffix to the model number, and metric designation
(M) gives the complete part number of WR12-506-06-D-M.

Performance Considerations
The following should be considered when selecting Enidine Wire Rope Isolator products:

Damping:
• Typically 5-15%, depending on size and input level. For specific damping considerations, please consult Enidine.

Stabilizers:
• Consider the use of stabilizers when the Height vs. Width ratio is greater than 2.

Natural Frequency Curve Basis:


• Published natural frequency curves are based on a 1G input condition. Natural frequency shifts may result from various
input levels.

Severe Input Considerations:


• Increase diameter of the wire rope cable.
• Increase height of the Wire Rope Isolators.
• Consult Enidine.

Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 3


CWR-coverNEW/RED 11/20/02 2:42 PM Page 8

WR2 Series

3.13
(79,5)
2.690 W
(68,3)

.40 Ø.062 H
(10,2) (1,6)

See
Mounting View Rotated .16
Note: Dimensions are in inches (mm). Options 90º CW for clarity (4,1)

U.S. Patent 5,549,285


Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR2-100-10-[ ] B, D, E 0.70 1.00 0.05
WR2-200-10-[ ] S, A, B, C, D, E 0.80 1.10 0.05
WR2-400-10-[ ] S, A, B, C, D, E 1.00 1.20 0.07
WR2-600-10-[ ] S, A, B, C, D, E 1.10 1.30 0.07
WR2-700-10-[ ] S, A, B, C, D, E 1.20 1.40 0.07
WR2-800-10-[ ] S, A, B, C, D, E 1.30 1.50 0.07

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR2-100-10-[ ] BM, DM, EM 18 25 0,02
WR2-200-10-[ ] S, AM, BM, CM, DM, EM 20 28 0,02
WR2-400-10-[ ] S, AM, BM, CM, DM, EM 25 30 0,03
WR2-600-10-[ ] S, AM, BM, CM, DM, EM 28 33 0,03
WR2-700-10-[ ] S, AM, BM, CM, DM, EM 30 36 0,03
WR2-800-10-[ ] S, AM, BM, CM, DM, EM 33 38 0,03

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
#8-32 M4 (x 0,7)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole
Countersunk Hole Maximum recommended torque for
Hole threaded insert is 6 in.-lbs. (0,7 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

4 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 9

WR2 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY 1
1 1 WR2-100-10
2 WR2-200-10 2
3 WR2-400-10
2 4 WR2-600-10
5 WR2-700-10
6 WR2-800-10 3

3
4

4 5
5
6
6

1
KEY
1 WR2-100-10
2 WR2-200-10
1 2
3 WR2-400-10
4 WR2-600-10
2 5 WR2-700-10
6 WR2-800-10
3
3
4
4
5
5
6 6

KEY
1 1 WR2-100-10
1
2 WR2-200-10
3 WR2-400-10
4 WR2-600-10 2
2 5 WR2-700-10
6 WR2-800-10

3
3
4
4
5 5
6
6

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 5
CWR-coverNEW/RED 11/20/02 2:42 PM Page 10

WR3 Series

4.42
(112,3)
3.950 W
(100,3)

.50 Ø.094 H
(12,7) (2,4)

See .25
Mounting View Rotated
Note: Dimensions are in inches (mm). 90º CW for clarity (6,4)
Options
U.S. Patent 5,549,285
Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR3-100-10-[ ] B, D, E 0.90 1.10 0.14
WR3-200-10-[ ] S, A, B, C, D, E 1.00 1.20 0.15
WR3-400-10-[ ] S, A, B, C, D, E 1.10 1.30 0.15
WR3-600-10-[ ] S, A, B, C, D, E 1.30 1.50 0.15
WR3-700-10-[ ] S, A, B, C, D, E 1.40 1.60 0.16
WR3-800-10-[ ] S, A, B, C, D, E 1.50 1.70 0.18

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR3-100-10-[ ] BM, DM, EM 23 28 0,06
WR3-200-10-[ ] S, AM, BM, CM, DM, EM 25 30 0,07
WR3-400-10-[ ] S, AM, BM, CM, DM, EM 28 33 0,07
WR3-600-10-[ ] S, AM, BM, CM, DM, EM 33 38 0,07
WR3-700-10-[ ] S, AM, BM, CM, DM, EM 36 41 0,07
WR3-800-10-[ ] S, AM, BM, CM, DM, EM 38 43 0,08

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
#10-32 M5 (x 0,8)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded insert is 8 in.-lbs. (0,9 Nm)

Standard Materials & Finishes*


E(M) Cable: Stranded 300 Series Stainless Steel
C(M) D(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

6 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 11

WR3 Series
Load vs. Deflection Load vs.
Natural Frequency

1 1
KEY
1 WR3-100-10
2 2 WR3-200-10
2
3 WR3-400-10
4 WR3-600-10
5 WR3-700-10
3 3
6 WR3-800-10

4 4

5 5
6
6

1 1
KEY
1 WR3-100-10
2 WR3-200-10
2 3 WR3-400-10 2
4 WR3-600-10
5 WR3-700-10
3 6 WR3-800-10
3

4
4
5
6 5

1
1 KEY
1 WR3-100-10
2 WR3-200-10 2
2 3 WR3-400-10
4 WR3-600-10
5 WR3-700-10
3
6 WR3-800-10
3

4
4
5
6 5

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 7
CWR-coverNEW/RED 11/20/02 2:42 PM Page 12

WR4 Series

5.00
(127,0)
4.500 W
(114,3)

.56 Ø.125 H
(14,2) (3,2)

See .31
Mounting View Rotated
Note: Dimensions are in inches (mm). Options 90º CW for clarity (7,9)

Imperial U.S. Patent 5,549,285

SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR4-100-10-[ ] B, D, E 1.10 1.40 0.26
WR4-200-10-[ ] B, D, E 1.20 1.50 0.26
WR4-400-10-[ ] S, A, B, C, D, E 1.30 1.60 0.29
WR4-500-10-[ ] S, A, B, C, D, E 1.40 1.70 0.29
WR4-600-10-[ ] S, A, B, C, D, E 1.50 1.80 0.29
WR4-700-10-[ ] S, A, B, C, D, E 1.60 1.90 0.30
WR4-800-10-[ ] S, A, B, C, D, E 1.70 2.00 0.30

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR4-100-10-[ ] BM, DM, EM 28 36 0,12
WR4-200-10-[ ] BM, DM, EM 30 38 0,12
WR4-400-10-[ ] S, AM, BM, CM, DM, EM 33 41 0,13
WR4-500-10-[ ] S, AM, BM, CM, DM, EM 36 43 0,13
WR4-600-10-[ ] S, AM, BM, CM, DM, EM 38 46 0,13
WR4-700-10-[ ] S, AM, BM, CM, DM, EM 41 48 0,14
WR4-800-10-[ ] S, AM, BM, CM, DM, EM 43 51 0,14

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded insert is 36 in.-lbs. (3,7 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

8 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 13

WR4 Series
Load vs. Deflection Load vs.
Natural Frequency

1
KEY
1 WR4-100-10 2
2 WR4-200-10
3 WR4-400-10
4 WR4-500-10 3
1
5 WR4-600-10
2
6 WR4-700-10 4
7 WR4-800-10

3 5

4 6
5
6 7
7

1
KEY
1 WR4-100-10
2
2 WR4-200-10
1 3 WR4-400-10
4 WR4-500-10 3
2 5 WR4-600-10
6 WR4-700-10 4
3 7 WR4-800-10

4 5

5 6
6
7 7

1
KEY
1 WR4-100-10
2 WR4-200-10 2
3 WR4-400-10
1 4 WR4-500-10 3
5 WR4-600-10
2 6 WR4-700-10
4
7 WR4-800-10
5
3

4 6

5 7
6

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 9
CWR-coverNEW/RED 11/20/02 2:42 PM Page 14

WR5 Series
5.00
(127,0)
4.500 W
(114,3)

.56 Ø.156
H
(14,2) (4,0)

See
Mounting View Rotated .31
Options 90º CW for clarity (7,9)
Note: Dimensions are in inches (mm).

U.S. Patent 5,549,285


Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR5-200-10-[ ] B, D, E 1.20 1.60 0.33
WR5-400-10-[ ] S, A, B, C, D, E 1.30 1.70 0.33
WR5-600-10-[ ] S, A, B, C, D, E 1.50 1.90 0.35
WR5-800-10-[ ] S, A, B, C, D, E 1.80 2.10 0.38
WR5-900-10-[ ] S, A, B, C, D, E 2.10 2.50 0.39

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR5-200-10-[ ] BM, DM, EM 30 41 0,15
WR5-400-10-[ ] S, AM, BM, CM, DM, EM 33 43 0,15
WR5-600-10-[ ] S, AM, BM, CM, DM, EM 38 48 0,16
WR5-800-10-[ ] S, AM, BM, CM, DM, EM 46 53 0,17
WR5-900-10-[ ] S, AM, BM, CM, DM, EM 53 64 0,18

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded insert is 38 in.-lbs. (4,3 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

10 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 15

WR5 Series
Load vs. Deflection Load vs.
Natural Frequency

1
1 KEY
1 WR5-200-10
2 2 WR5-400-10 2
3 WR5-600-10
4 WR5-800-10
5 WR5-900-10
3
3

4
4
5

1
1 KEY
1 WR5-200-10
2 2 WR5-400-10 2
3 WR5-600-10
4 WR5-800-10
3 5 WR5-900-10
3

4
5

1
1 KEY
1 WR5-200-10
2 WR5-400-10 2
2 3 WR5-600-10
4 WR5-800-10
5 WR5-900-10
3
3

4
4

5
5

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 11
CWR-coverNEW/RED 11/20/02 2:42 PM Page 16

WR6 Series
5.00
(127,0)
4.500 W
(114,3)

.56 Ø.156
H
(14,2) (4,0)

See
Mounting View Rotated .31
Options 90º CW for clarity (7,9)
Note: Dimensions are in inches (mm).
U.S. Patent 5,549,285
Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR6-200-10-[ ] D 1.20 1.40 0.42
WR6-300-10-[ ] D 1.30 1.50 0.43
WR6-400-10-[ ] B, D, E 1.40 1.60 0.46
WR6-500-10-[ ] S, A, B, C, D, E 1.50 1.70 0.47
WR6-600-10-[ ] S, A, B, C, D, E 1.60 1.80 0.49
WR6-700-10-[ ] S, A, B, C, D, E 1.70 1.90 0.54
WR6-800-10-[ ] S, A, B, C, D, E 2.00 2.30 0.57
WR6-850-10-[ ] S, A, B, C, D, E 2.13 2.94 0.59
WR6-900-10-[ ] S, A, B, C, D, E 2.45 3.45 0.61
WR6-950-10-[ ] S, A, B, C, D, E 3.20 4.20 0.63

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR6-200-10-[ ] DM 30 36 0,19
WR6-300-10-[ ] DM 33 38 0,20
WR6-400-10-[ ] BM, DM, EM 36 41 0,21
WR6-500-10-[ ] S, AM, BM, CM, DM, EM 38 43 0,21
WR6-600-10-[ ] S, AM, BM, CM, DM, EM 41 46 0,22
WR6-700-10-[ ] S, AM, BM, CM, DM, EM 43 48 0,25
WR6-800-10-[ ] S, AM, BM, CM, DM, EM 51 58 0,26
WR6-850-10-[ ] S, AM, BM, CM, DM, EM 54 75 0,27
WR6-900-10-[ ] S, AM, BM, CM, DM, EM 62 88 0,28
WR6-950-10-[ ] S, AM, BM, CM, DM, EM 81 107 0,29

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
1/4-20 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded insert is 38 in.-lbs. (4,3 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

12 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 17

WR6 Series
Load vs. Deflection Load vs.
Natural Frequency

1
KEY
1 1 WR6-200-10 2
2 2 WR6-300-10
3 3 WR6-400-10
3
4 4 WR6-500-10
5 WR6-600-10 4
5 6 WR6-700-10
6 7 WR6-800-10 5
8 WR6-850-10
9 WR6-900-10 6
10 WR6-950-10
7

7
8

9
8
10
9
10

1
KEY
1 1 WR6-200-10 2
2 2 WR6-300-10
3 3 WR6-400-10
4 WR6-500-10
3
4
5 WR6-600-10 4
5 6 WR6-700-10
6 7 WR6-800-10 5
8 WR6-850-10
9 WR6-900-10 6
10 WR6-950-10
7

8 7

9
8
10
9
10

1
2
KEY 3
1 1 WR6-200-10
2 2 WR6-300-10
4
3 3 WR6-400-10
5
4 4 WR6-500-10
5 WR6-600-10
5 6 WR6-700-10 6
6 7 WR6-800-10
8 WR6-850-10 7
9 WR6-900-10
10 WR6-950-10
7

8 9
9
10 10

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 13
CWR-coverNEW/RED 11/20/02 2:42 PM Page 18

WR8 Series
5.75
(146,1)
5.162 W
(131,1)

.63 Ø.250 H
(16,0) (6,4)

See
Mounting View Rotated .50
Note: Dimensions are in inches (mm). Options 90º CW for clarity (12,7)

Imperial U.S. Patent 5,549,285

SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR8-200-08-[ ] S, A, B, C, D, E 1.90 2.20 0.84
WR8-400-08-[ ] S, A, B, C, D, E 2.13 2.50 0.90
WR8-500-08-[ ] S, A, B, C, D, E 2.31 2.80 0.94
WR8-600-08-[ ] S, A, B, C, D, E 2.50 3.13 1.04
WR8-700-08-[ ] S, A, B, C, D, E 2.50 3.50 1.14
WR8-800-08-[ ] S, A, B, C, D, E 2.63 3.75 1.20
WR8-850-08-[ ] S, A, B, C, D, E 2.63 3.95 1.25
WR8-900-08-[ ] S, A, B, C, D, E 3.25 4.25 1.30

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR8-200-08-[ ] S, AM, BM, CM, DM, EM 48 56 0,38
WR8-400-08-[ ] S, AM, BM, CM, DM, EM 54 64 0,41
WR8-500-08-[ ] S, AM, BM, CM, DM, EM 59 71 0,43
WR8-600-08-[ ] S, AM, BM, CM, DM, EM 64 80 0,47
WR8-700-08-[ ] S, AM, BM, CM, DM, EM 64 89 0,52
WR8-800-08-[ ] S, AM, BM, CM, DM, EM 67 95 0,54
WR8-850-08-[ ] S, AM, BM, CM, DM, EM 67 100 0,57
WR8-900-08-[ ] S, AM, BM, CM, DM, EM 83 108 0,59

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
1/4-28 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded insert is 38 in.-lbs. (4,3 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M)
Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded
Threaded Countersunk
Hole

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

14 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 19

WR8 Series
Load vs. Deflection Load vs.
Natural Frequency

1 1
KEY
1 WR8-200-08
2 WR8-400-08
2 3 WR8-500-08 2
4 WR8-600-08
3 5 WR8-700-08
6 WR8-800-08 3
7 WR8-850-08
4 8 WR8-900-08
4
5
6 5
7 6
8 7

KEY
1 1 WR8-200-08 1
2 WR8-400-08
3 WR8-500-08 2
2 4 WR8-600-08
5 WR8-700-08
6 WR8-800-08
3 3
7 WR8-850-08
8 WR8-900-08
4
5 4
6
5
7
8 6

7
8

1 KEY
1 WR8-200-08 1
2 WR8-400-08
2 3 WR8-500-08 2
4 WR8-600-08
5 WR8-700-08 3
3 6 WR8-800-08
7 WR8-850-08 4
4 8 WR8-900-08
5
6 5
7

8 6

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 15
CWR-coverNEW/RED 11/20/02 2:43 PM Page 20

WR12 Series 6 LOOP


6.66
(169,2)
6.125
(155,6)
4.375
(111,1)
.27 1.750 W
(6,9) (44,5)

1.00 Ø .375 H
(25,4) (9,5)

See
Mounting View Rotated .63
Note: Dimensions are in inches (mm). Options 90º CW for clarity (16,0)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(lbs.)
OPTION [ ] (in.) (in.)
WR12-206-06-[ ] S, A, B, C, D, E 2.80 3.31 1.82
WR12-306-06-[ ] S, A, B, C, D, E 2.90 3.50 1.88
WR12-406-06-[ ] S, A, B, C, D, E 3.00 4.13 1.99
WR12-506-06-[ ] S, A, B, C, D, E 3.25 4.25 2.09
WR12-606-06-[ ] S, A, B, C, D, E 3.50 4.25 2.15
WR12-706-06-[ ] S, A, B, C, D, E 4.13 4.75 2.36
WR12-806-06-[ ] S, A, B, C, D, E 4.25 5.50 2.48

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR12-206-06-[ ] SM, AM, BM, CM, DM, EM 71 84 0,83
WR12-306-06-[ ] SM, AM, BM, CM, DM, EM 74 89 0,85
WR12-406-06-[ ] SM, AM, BM, CM, DM, EM 76 105 0,90
WR12-506-06-[ ] SM, AM, BM, CM, DM, EM 83 108 0,95
WR12-606-06-[ ] SM, AM, BM, CM, DM, EM 89 108 0,98
WR12-706-06-[ ] SM, AM, BM, CM, DM, EM 105 121 1,07
WR12-806-06-[ ] SM, AM, BM, CM, DM, EM 108 140 1,13

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) IMPERIAL METRIC
1/4-28 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
threaded bar is 100 in.-lbs. (10 Nm)
Hole

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded
Threaded Countersunk Alloy Steel, Zinc Plated
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

16 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 21

WR12 Series 6 LOOP


Load vs. Deflection Load vs.
Natural Frequency

KEY 1
1 1 WR12-206-06
2 WR12-306-06
2 3 WR12-406-06 2
4 WR12-506-06
5 WR12-606-06
3 6 WR12-706-06 3
7 WR12-806-06
4
4
5

5
6

7 6

KEY
1 WR12-206-06
2 WR12-306-06 1
1 3 WR12-406-06
2 4 WR12-506-06
5 WR12-606-06 2
6 WR12-706-06
3 7 WR12-806-06

4 3
5
4
6
5
7
6

1
KEY
1 WR12-206-06
1 2 WR12-306-06
3 WR12-406-06
2
2 4 WR12-506-06
5 WR12-606-06
6 WR12-706-06 3
7 WR12-806-06
3
4
4
5
5

6 6
7
7

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 17
CWR-coverNEW/RED 11/20/02 2:43 PM Page 22

WR12 Series
8.50
(215,9)
6.125
(155,6)
4.375
(111,1)
1.19 1.750 W
(30,2) (44,5)

1.00 Ø .375 H
(25,4) (9,5)

See
Mounting View Rotated .63
Note: Dimensions are in inches (mm). Options 90º CW for clarity (16,0)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR12-200-08-[ ] S, A, B, C, D, E 2.80 3.31 2.43
WR12-300-08-[ ] S, A, B, C, D, E 2.90 3.50 2.50
WR12-400-08-[ ] S, A, B, C, D, E 3.00 4.13 2.65
WR12-500-08-[ ] S, A, B, C, D, E 3.25 4.25 2.78
WR12-600-08-[ ] S, A, B, C, D, E 3.50 4.25 2.87
WR12-700-08-[ ] S, A, B, C, D, E 4.13 4.75 3.15
WR12-800-08-[ ] S, A, B, C, D, E 4.25 5.50 3.31

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR12-200-08-[ ] SM, AM, BM, CM, DM, EM 71 84 1,10
WR12-300-08-[ ] SM, AM, BM, CM, DM, EM 74 89 1,13
WR12-400-08-[ ] SM, AM, BM, CM, DM, EM 76 105 1,20
WR12-500-08-[ ] SM, AM, BM, CM, DM, EM 83 108 1,26
WR12-600-08-[ ] SM, AM, BM, CM, DM, EM 89 108 1,30
WR12-700-08-[ ] SM, AM, BM, CM, DM, EM 105 121 1,43
WR12-800-08-[ ] SM, AM, BM, CM, DM, EM 108 140 1,50

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) IMPERIAL METRIC
1/4-28 M8 (x 1,25)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole threaded bar is 100 in.-lbs. (20 Nm)
Hole

Standard Materials & Finishes*


Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded Alloy Steel, Zinc Plated
Threaded Countersunk
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

18 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 23

WR12 Series
Load vs. Deflection Load vs.
Natural Frequency

1 KEY 1
1 WR12-200-08
2 2 WR12-300-08
3 WR12-400-08 2
4 WR12-500-08
5 WR12-600-08
3
6 WR12-700-08
4 7 WR12-800-08 3

5 4

5
6
7
6

KEY 1
1 WR12-200-08
1
2 WR12-300-08
2 3 WR12-400-08
2
4 WR12-500-08
5 WR12-600-08
3 6 WR12-700-08
4 7 WR12-800-08
3
5

4
6
5
7
6
7

1
KEY
1 WR12-200-08
2 WR12-300-08 2
1 3 WR12-400-08
2 4 WR12-500-08
5 WR12-600-08
6 WR12-700-08
3 7 WR12-800-08
3

4
4
5
5

7 6

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 19
CWR-coverNEW/RED 11/20/02 2:43 PM Page 24

WR16 Series 6 LOOP


7.00
(177,8)
6.125
(155,6)
4.375
(111,1)
.44 1.750 W
(11,2) (44,5)

1.00 Ø .500 H
(25,4) (12,7)

See
Mounting View Rotated .75
Note: Dimensions are in inches (mm). Options 90º CW for clarity (19,1)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR16-206-06-[ ] S, A, B, C, D, E 3.00 3.63 3.00
WR16-306-06-[ ] S, A, B, C, D, E 3.25 4.00 3.15
WR16-406-06-[ ] S, A, B, C, D, E 3.50 4.13 3.30
WR16-606-06-[ ] S, A, B, C, D, E 3.75 4.75 3.68
WR16-706-06-[ ] S, A, B, C, D, E 4.25 5.25 3.98
WR16-806-06-[ ] S, A, B, C, D, E 4.90 5.65 4.46
WR16-856-06-[ ] S, A, B, C, D, E 5.40 6.13 4.80
WR16-906-06-[ ] S, A, B, C, D, E 6.10 7.10 5.10

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR16-206-06-[ ] SM, AM, BM, CM, DM, EM 76 92 1,36
WR16-306-06-[ ] SM, AM, BM, CM, DM, EM 83 102 1,43
WR16-406-06-[ ] SM, AM, BM, CM, DM, EM 89 105 1,50
WR16-606-06-[ ] SM, AM, BM, CM, DM, EM 95 121 1,67
WR16-706-06-[ ] SM, AM, BM, CM, DM, EM 108 133 1,81
WR16-806-06-[ ] SM, AM, BM, CM, DM, EM 124 144 2,02
WR16-856-06-[ ] SM, AM, BM, CM, DM, EM 137 156 2,18
WR16-906-06-[ ] SM, AM, BM, CM, DM, EM 155 180 2,31

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) IMPERIAL METRIC
1/4-28 (Threaded Only) M8 (x 1,25)
5/16-24 (All Others) M8 (x 1,25)
Thru Hole Countersunk
Thru Hole 82º COUNTERSINK 90º COUNTERSINK
Countersunk Hole
Hole Maximum recommended torque for
threaded bar is 115 in.-lbs. (20 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M)
Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded Assembly Hardware (WR12 – WR40):
Threaded Countersunk
Hole Alloy Steel, Zinc Plated

Operating Temperature Range


* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.
-150ºF to 500ºF ( -100ºC to 260ºC )

20 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 25

WR16 Series 6 LOOP


Load vs. Deflection Load vs.
Natural Frequency

1
KEY 1
1 WR16-206-06
2 2 WR16-306-06
3 WR16-406-06 2
3 4 WR16-606-06
5 WR16-706-06
6 WR16-806-06 3
4 7 WR16-856-06
8 WR16-906-06
4
5

6 5
7
6
8
7
8

KEY
1 1 WR16-206-06
2 WR16-306-06
2 3 WR16-406-06
4 WR16-606-06
3
5 WR16-706-06
6 WR16-806-06 1
4 7 WR16-856-06
8 WR16-906-06 2

5 3

6 4

7 5
8 6
7
8

KEY 1
1 WR16-206-06
1 2 WR16-306-06
3 WR16-406-06
2 4 WR16-606-06
2
3 5 WR16-706-06
6 WR16-806-06 3
7 WR16-856-06
4 8 WR16-906-06

5 4

6
7 5
8
6
7
8

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 21
CWR-coverNEW/RED 11/20/02 2:43 PM Page 26

WR16 Series
8.50
(215,9)
6.125
(155,6)
4.375
(111,1)
1.750 W
1.19 (44,5)
(30,2)

1.00 Ø .500 H
(25,4) (12,7)

See
Mounting View Rotated .75
Note: Dimensions are in inches (mm). Options 90º CW for clarity (19,1)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR16-200-08-[ ] S, A, B, C, D, E 3.00 3.63 4.00
WR16-300-08-[ ] S, A, B, C, D, E 3.25 4.00 4.20
WR16-400-08-[ ] S, A, B, C, D, E 3.50 4.13 4.40
WR16-600-08-[ ] S, A, B, C, D, E 3.75 4.75 4.90
WR16-700-08-[ ] S, A, B, C, D, E 4.25 5.25 5.30
WR16-800-08-[ ] S, A, B, C, D, E 4.90 5.65 5.95
WR16-850-08-[ ] S, A, B, C, D, E 5.40 6.13 6.40
WR16-900-08-[ ] S, A, B, C, D, E 6.10 7.10 6.80

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR16-200-08-[ ] SM, AM, BM, CM, DM, EM 76 92 1,81
WR16-300-08-[ ] SM, AM, BM, CM, DM, EM 83 102 1,91
WR16-400-08-[ ] SM, AM, BM, CM, DM, EM 89 105 2,00
WR16-600-08-[ ] SM, AM, BM, CM, DM, EM 95 121 2,22
WR16-700-08-[ ] SM, AM, BM, CM, DM, EM 108 133 2,40
WR16-800-08-[ ] SM, AM, BM, CM, DM, EM 124 144 2,70
WR16-850-08-[ ] SM, AM, BM, CM, DM, EM 137 156 2,90
WR16-900-08-[ ] SM, AM, BM, CM, DM, EM 155 180 3,09

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) IMPERIAL METRIC
1/4-28 (Threaded Only) M8 (x 1,25)
5/16-24 (All Others) M8 (x 1,25)
Thru Hole Countersunk
Thru Hole 82º COUNTERSINK 90º COUNTERSINK
Countersunk Hole
Hole Maximum recommended torque for
threaded bar is 115 in.-lbs. (20 Nm)

Standard Materials & Finishes*


C(M) D(M) E(M) Cable: Stranded 300 Series Stainless Steel
Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded MIL-C-5541
Threaded Assembly Hardware (WR12 – WR40):
Threaded Countersunk
Hole Alloy Steel, Zinc Plated

Operating Temperature Range


* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements. -150ºF to 500ºF ( -100ºC to 260ºC )

22 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 27

WR16 Series
Load vs. Deflection Load vs.
Natural Frequency

1 1
KEY
1 WR16-200-08
2 WR16-300-08 2
2
3 WR16-400-08
3 4 WR16-600-08
5 WR16-700-08 3
4 6 WR16-800-08
7 WR16-850-08
8 WR16-900-08 4
5

6
5
7
6
8
7
8

1
KEY
1 WR16-200-08
2
2 WR16-300-08
3 3 WR16-400-08
4 WR16-600-08 1
5 WR16-700-08
4 6 WR16-800-08 2
7 WR16-850-08
5 8 WR16-900-08
3
6
4
7
8 5
6
7
8

1
1 KEY
1 WR16-200-08
2 WR16-300-08
2
2 3 WR16-400-08
4 WR16-600-08
3 5 WR16-700-08 3
6 WR16-800-08
7 WR16-850-08
4 8 WR16-900-08
4
5

6 5
7
6
8
7
8

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 23
CWR-coverNEW/RED 11/20/02 2:43 PM Page 28

WR20 Series
10.50
(266,7)
7.525
(191,1)
5.375
(136,5)
1.49 2.150
(54,6) W
(37,8)

1.00 Ø .625 H
(25,4) (15,9)

See
Mounting View Rotated 1.00
Note: Dimensions are in inches (mm). Options 90º CW for clarity (25,4)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR20-200-08-[ ] C, D 3.50 4.00 6.62
WR20-300-08-[ ] S, A, B, C, D, E 3.90 4.40 7.06
WR20-400-08-[ ] S, A, B, C, D, E 4.00 4.75 7.50
WR20-600-08-[ ] S, A, B, C, D, E 4.30 5.31 8.16
WR20-700-08-[ ] S, A, B, C, D, E 4.70 6.00 8.83
WR20-800-08-[ ] S, A, B, C, D, E 5.00 6.50 9.50
WR20-900-08-[ ] S, A, B, C, D, E 5.30 7.00 10.20

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W) (Kg)
OPTION [ ] (mm) (mm)
WR20-200-08-[ ] CM, DM 89 102 3,00
WR20-300-08-[ ] S, AM, BM, CM, DM, EM 99 112 3,20
WR20-400-08-[ ] S, AM, BM, CM, DM, EM 102 121 3,40
WR20-600-08-[ ] S, AM, BM, CM, DM, EM 109 135 3,70
WR20-700-08-[ ] S, AM, BM, CM, DM, EM 119 152 4,00
WR20-800-08-[ ] S, AM, BM, CM, DM, EM 127 165 4,31
WR20-900-08-[ ] S, AM, BM, CM, DM, EM 135 178 4,63

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
3/8-24 M10 (x 1,5)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole threaded bar is 415 in.-lbs. (50 Nm)
Hole
Standard Materials & Finishes*
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded Alloy Steel, Zinc Plated
Threaded Countersunk
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

24 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 29

WR20 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 WR20-200-08 1
2 WR20-300-08
1 3 WR20-400-08
4 WR20-600-08 2
2
3 5 WR20-700-08
6 WR20-800-08 3
7 WR20-900-08
4

5 4
6
7 5

6
7

KEY
1 WR20-200-08
1 2 WR20-300-08
3 WR20-400-08
2 4 WR20-600-08 1
3 5 WR20-700-08
6 WR20-800-08
4 7 WR20-900-08 2

5 3

6
4
7
5
6
7

KEY 1
1 WR20-200-08
2 WR20-300-08
3 WR20-400-08
1 4 WR20-600-08 2
5 WR20-700-08
2 6 WR20-800-08
3 7 WR20-900-08 3

4
5 4

6
5
7
6
7

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 25
CWR-coverNEW/RED 11/20/02 2:43 PM Page 30

WR28 Series
14.50
(368,3)
10.500
(266,7)
7.500
(190,5)
2.00 3.000 W
(50,8) (76,2)

1.50 Ø .875 H
(38,1) (22,2)

See
Mounting View Rotated 1.50
Note: Dimensions are in inches (mm). Options 90º CW for clarity (38,1)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR28-200-08-[ ] S, C, D 5.25 5.50 18.5
WR28-400-08-[ ] S, A, B, C, D, E 6.00 6.50 21.0
WR28-600-08-[ ] S, A, B, C, D, E 6.25 7.00 21.8
WR28-800-08-[ ] S, A, B, C, D, E 7.50 8.25 25.3
WR28-900-08-[ ] S, A, B, C, D, E 8.50 9.25 28.0

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR28-200-08-[ ] CM, DM 133 140 8,40
WR28-400-08-[ ] S, AM, BM, CM, DM, EM 152 165 9,53
WR28-600-08-[ ] S, AM, BM, CM, DM, EM 159 178 9,90
WR28-800-08-[ ] S, AM, BM, CM, DM, EM 191 210 11,50
WR28-900-08-[ ] S, AM, BM, CM, DM, EM 216 235 12,70

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
1/2-13 M12 (x 1,75)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole threaded bar is 95 ft.-lbs. (100 Nm)
Hole
Standard Materials & Finishes*
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded Alloy Steel, Zinc Plated
Threaded Countersunk
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

26 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 31

WR28 Series
Load vs. Deflection Load vs.
Natural Frequency

1
KEY
1 WR28-200-08
2 WR28-400-08
3 WR28-600-08
2 4 WR28-800-08
3 5 WR28-900-08 1

4 2

5 3

KEY
1 WR28-200-08
1 2 WR28-400-08
3 WR28-600-08
4 WR28-800-08
5 WR28-900-08
2 1
3

2
4
3
5

4
5

1 KEY
1 WR28-200-08
2 WR28-400-08
3 WR28-600-08
4 WR28-800-08
2 5 WR28-900-08

3 1

2
4
3
5
4

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 27
CWR-coverNEW/RED 11/20/02 2:43 PM Page 32

WR36 Series
20.50
(520,7)
14.875
(377,8)
10.625
(269,9)
2.81 4.250 W
(71,4) (108,0)

2.00 Ø 1.125 H
(50,8) (28,6)

See
Mounting View Rotated 2.00
Note: Dimensions are in inches (mm). Options 90º CW for clarity (50,8)

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (lbs.)
OPTION [ ] (in.)
WR36-200-08-[ ] S, A, B, C, D, E 7.00 8.50 46
WR36-400-08-[ ] S, A, B, C, D, E 8.50 9.50 53
WR36-600-08-[ ] S, A, B, C, D, E 9.25 10.25 55

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR36-200-08-[ ] S, AM, BM, CM, DM, EM 178 216 20,9
WR36-400-08-[ ] S, AM, BM, CM, DM, EM 216 241 24,0
WR36-600-08-[ ] S, AM, BM, CM, DM, EM 235 260 25,0

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
3/4-10 M18 (x 2,5)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole
Hole threaded bar is 300 ft.-lbs. (300 Nm)

Standard Materials & Finishes*


Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded Alloy Steel, Zinc Plated
Threaded Countersunk
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

28 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 33

WR36 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 WR36-200-08
2 WR36-400-08
3 WR36-600-08
1
1

2
2
3

KEY
1 WR36-200-08
2 WR36-400-08
1 3 WR36-600-08

1
2
3 2

KEY
1 WR36-200-08
2 WR36-400-08
3 WR36-600-08
1

3
1

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 29
CWR-coverNEW/RED 11/20/02 2:43 PM Page 34

WR40 Series
20.50
(520,7)
14.875
(377,8)
10.625
(269,9)
2.81 4.250 W
(71,4) (108,0)

2.00 Ø 1.250 H
(50,8) (31,8)

See 2.00
Mounting View Rotated
Note: Dimensions are in inches (mm). 90º CW for clarity (50,8)
Options

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (lbs.)
OPTION [ ]
WR40-200-08-[ ] S, A, B, C, D, E 7.00 8.25 53
WR40-400-08-[ ] S, A, B, C, D, E 8.50 9.75 60

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (Kg)
OPTION [ ] (mm) (mm)
WR40-200-08-[ ] S, AM, BM, CM, DM, EM 178 210 24,0
WR40-400-08-[ ] S, AM, BM, CM, DM, EM 216 248 27,2

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) B(M) IMPERIAL METRIC
3/4-10 M18 (x 2,5)
82º COUNTERSINK 90º COUNTERSINK
Thru Hole Countersunk
Thru Hole Maximum recommended torque for
Countersunk Hole threaded bar is 300 ft.-lbs. (300 Nm)
Hole

Standard Materials & Finishes*


Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541
Thru Hole Threaded Assembly Hardware (WR12 – WR40):
Threaded Alloy Steel, Zinc Plated
Threaded Countersunk
Hole
Operating Temperature Range
-150ºF to 500ºF ( -100ºC to 260ºC )
* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

30 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 35

WR40 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 WR40-200-08
1 2 WR40-400-08

2
1

KEY
1 WR40-200-08
1 2 WR40-400-08

2 1

KEY
1 WR40-200-08
1 2 WR40-400-08

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 31
CWR-coverNEW/RED 11/20/02 2:43 PM Page 36

Selecting An Enidine Compact Wire Rope Isolator


SIZING INSTRUCTIONS - VIBRATION ISOLATION SIZING INSTRUCTIONS - SHOCK ISOLATION
If the desired system natural frequency is known, refer to the appropriate Load Selecting appropriate isolators for shock is based on the Compact Wire Rope
vs. Natural Frequency curves to determine the recommended Compact Wire Isolator’s average stiffness at the required dynamic deflection (Dmin). Follow the
Rope Isolator model. If the preferred system natural frequency is unknown, steps below to achieve a recommended Compact Wire Rope Isolator selection.
follow the steps below to achieve a recommended Compact Wire Rope Isolator
selection. STEP 1: Fill out Part I and Part III of the Application Worksheet.

STEP 1: Fill out Part I and Part II of the Application Worksheet. STEP 2: Refer to the Load vs. Deflection curves for the desired loading
orientation. Locate curves capable of the Minimum Dynamic
STEP 2: Refer to the Load vs. Natural Frequency curves for the required Deflection (Dmin) calculated from the worksheet. Find a curve that
loading orientation. Use the System Natural Frequency (ƒn ) is on or slightly under the Average Force (Favg) at the Average
calculated from the worksheet to select the smallest Compact
Wire Rope Isolator model capable of the static load (W). Deflection (davg) calculated from the worksheet.

STEP 3: Specify the required mounting option suffix to complete the part STEP 3: Specify the required mounting option suffix to complete the part
number. (Please refer to available mounting options as indicated on number. (Please refer to available mounting options as indicated on
each Compact Wire Rope Isolator series data page.) each Compact Wire Rope Isolator series data page.)

APPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC


IMPERIAL METRIC
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________

3. Static Load per Isolator (W): W = WT W = ________ lbs.* W = ________ N*


n
* Assumes a central CG
4. Load Axis: Compression Load Axis Load Axis
Shear or Roll
45º Compression/Roll ____________________ ___________________

PART II: VIBRATION SIZING:


1. Input Excitation Frequency (ƒi) = ________ Hz ( = rpm
60
)
ƒi
2. System Natural Frequency for 80% isolation: ƒn = ƒn = ________ Hz* ƒn = ________ Hz*
3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.
The published natural frequencies are based on a 1G input condition.
Random Vibration inputs: Consult Enidine for recommendations.

PART III: SHOCK SIZING:


1. Maximum Allowable Transmitted G Load: (GT): ________G’s
2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2

a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2


V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input: A0 = Peak Acceleration (G’s)
t0 = Duration (seconds)
V = 2 g A0 t0
π

Imperial Metric
2 2
V V
3. Min. Response Deflection: Dmin = Dmin = Dmin = ________in. Dmin = ________mm
g (GT – 1) g (GT – 1) 1000

2 2
4. Average Force: Favg = WV Favg WV Favg = ________lbs. Favg = ________N
=
2g Dmin 2g ( Dmin ) 1000

davg = Dmin davg = ________in. davg = ________mm


5. Average Deflection:
2

Ordering Information
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).
EXAMPLE:
20 CR6 – 100 – * – [ ]
1. Select Quantity 2. CR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
Specify Model Number
**Please refer to available mounting options as indicated on each CR series data page.
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.

32 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 37

Selecting An Enidine Compact Wire Rope Isolator

VIBRATION ISOLATION:

A 6-lb. electronics box is failing due to a 40 Hz vibration input. Only .75 inches of space exists around the unit for an
isolator. To control the damaging effects of vibration, the box shall be isolated using four (4) isolators mounted in the
compression load axis with imperial, socket head cap screws. The isolators shall be located symmetrically about the
pump’s center of gravity.

Step 1: From Part I and Part II of the Application Worksheet.


WT = 6 lbs. Fi = 40 Hz

6 40
W = = 1.50 lbs. Fn = = 13.3 Hz
4 3
Step 2: Determine which isolators match the desired height requirement. The CR1-100, CR2-200, and the CR3-100
each have a height of .75 inches.
Step 3: Referring to the Compression Load vs. Natural Frequency curves for an isolator capable of a maximum
static load of 1.5 lbs., and a System Natural Frequency of approximately 13.3 Hz, yields a recommended
isolator of CR2-200.

Step 4: From the Available Mounting Options column, verify that a “D” mounting style is available (for threaded
holes in both mount bars). Adding the mounting option suffix to the model number gives the complete part
number of CR2-200-D.

SHOCK ISOLATION:

A 1.31-lb. computer hard drive is mounted inside a vehicle and must withstand a half-sine shock input of 30G’s, 5 in./sec.
The hard drive shall be suspended inside of the vehicle using four (4) isolators (2 per side) in a roll loading axis with
imperial, socket head cap screws. The hard drive can withstand a maximum shock response of 10G’s. The isolators
shall be installed symmetrically about the equipment’s center of gravity.

Step 1: From Part I and Part III of the Application Worksheet.


2 (386) Favg = (.33)(36.86)2
V= (30)(.005) = 36.86 in./sec. = 1.49 lbs.
π 2(386)(.39)
36.862 davg = .39
= .195 inches
Dmin = = .39 inches
386 (10 – 1) 2
Step 2: Referring to the Shear/Roll Load vs. Deflection curves for an isolator capable of a maximum deflection
of .39 inches or greater, and a curve point that is at or slightly below a force of 1.49 lbs., at .195 inches
of deflection, yields a recommended isolator selection of CR3-300.

Step 3: From the Available Mounting Options column, verify that a “D” mounting style is available (for threaded
holes in both mount bars). Adding the mounting option suffix to the model number, gives the complete part
number of CR3-300-D.
Performance Considerations
The following should be considered when selecting Enidine Wire Rope Isolator products:

Damping:
• Typically 5-15%, depending on size and input level. For specific damping considerations, please consult Enidine.

Stabilizers:
• Consider use of stabilizers when Height vs. Width ratio is greater than 2.

Natural Frequency Curve Basis:


• Published natural frequency curves are based on a 1G input condition. Natural frequency shifts may result from various
input levels.

Severe Input Considerations:


• Increase diameter of the wire rope cable.
• Increase height of the Compact Wire Rope Isolators.
• Consult Enidine.

Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 33


CWR-coverNEW/RED 11/20/02 2:43 PM Page 38

CR1 Series
.44
(11,2) W
.16 (4,1)
.22 TYP See
(5,6) Mounting
Options

.64
W H (16,3)

.32
(8,1) .19
View Rotated (4,8)
90º CW for clarity
.38
(9,7)
Note: Dimensions are in inches (mm).
U.S. Patent 6,290,217

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (oz.)
OPTION [ ]
CR1-100-[ ] S, A, B, C, D, E 0.66 0.73 0.11
CR1-200-[ ] S, A, B, C, D, E 0.75 0.79 0.11
CR1-300-[ ] S, A, B, C, D, E 0.90 0.91 0.12
CR1-400-[ ] S, A, B, C, D, E 1.04 1.03 0.12

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR1-100-[ ] S, AM, BM, CM, DM, EM 17 19 3,1
CR1-200-[ ] S, AM, BM, CM, DM, EM 19 20 3,1
CR1-300-[ ] S, AM, BM, CM, DM, EM 23 23 3,4
CR1-400-[ ] S, AM, BM, CM, DM, EM 26 26 3,4

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) Countersunk
B(M) Countersunk IMPERIAL METRIC
Thru Hole
Hole Hole #4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 10 in.-lbs. (1,2 Nm)

Thru Hole Thru Hole


Countersunk Standard Materials & Finishes*
Hole
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Countersunk Retaining Bars: Aluminum Alloy, treated per
Threaded Threaded
Hole MIL-C-5541

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )

Thru Hole Threaded Threaded

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

34 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 2/5/03 5:10 PM Page 39

CR1 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY 1
1 1 CR1-100
2 CR1-200
3 CR1-300
4 CR1-400
2 2

4 3

KEY
1 1 CR1-100
2 CR1-200 1
3 CR1-300
4 CR1-400
2
2

3
4

KEY
1 CR1-100
2 CR1-200
1 3 CR1-300
4 CR1-400 1

2
2

3
3

4
4

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 35
CWR-coverNEW/RED 11/20/02 2:43 PM Page 40

CR2 Series
.44
(11,2) W
.16 (4,1)
.22 TYP See
(5,6) Mounting
Options

.64
W H (16,3)

.32
View Rotated (8,1) .19
90º CW for clarity (4,8)
.38
(9,7)

Note: Dimensions are in inches (mm). U.S. Patent 6,290,217

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (oz.)
OPTION [ ]
CR2-100-[ ] S, A, B, C, D, E 0.64 0.78 0.13
CR2-200-[ ] S, A, B, C, D, E 0.75 0.83 0.14
CR2-300-[ ] S, A, B, C, D, E 0.89 0.94 0.15
CR2-400-[ ] S, A, B, C, D, E 1.07 1.06 0.16

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR2-100-[ ] S, AM, BM, CM, DM, EM 16 20 3,7
CR2-200-[ ] S, AM, BM, CM, DM, EM 19 21 4,0
CR2-300-[ ] S, AM, BM, CM, DM, EM 23 24 4,3
CR2-400-[ ] S, AM, BM, CM, DM, EM 27 27 4,5

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) Countersunk
B(M) Countersunk IMPERIAL METRIC
Thru Hole
Hole Hole #4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 10 in.-lbs. (1,2 Nm)

Thru Hole Thru Hole


Countersunk Standard Materials & Finishes*
Hole
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Countersunk Retaining Bars: Aluminum Alloy, treated per
Threaded Threaded
Hole MIL-C-5541

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )

Thru Hole Threaded Threaded

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

36 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 41

CR2 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 CR2-100 1
1 2 CR2-200
3 CR2-300
4 CR2-400
2
2

4
3

KEY 1
1 1 CR2-100
2 CR2-200
2 3 CR2-300
4 CR2-400 2

3
4

KEY
1 CR2-100 1
1 2 CR2-200
3 CR2-300
4 CR2-400
2

2
3

4 3

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 37
CWR-coverNEW/RED 11/20/02 2:43 PM Page 42

CR3 Series
.50
(12,7) W
.19 (4,8)
.25 TYP See
(6,4) Mounting
Options

.76
W H (19,3)

.39
View Rotated (9,9) .19
90º CW for clarity (4,8)
.38
(9,7)
Note: Dimensions are in inches (mm).
U.S. Patent 6,290,217

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (oz.)
OPTION [ ]
CR3-100-[ ] S, A, B, C, D, E 0.75 0.88 0.20
CR3-200-[ ] S, A, B, C, D, E 0.90 0.95 0.22
CR3-300-[ ] S, A, B, C, D, E 1.06 1.06 0.24
CR3-400-[ ] S, A, B, C, D, E 1.28 1.20 0.26

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR3-100-[ ] S, AM, BM, CM, DM, EM 19 22 5,7
CR3-200-[ ] S, AM, BM, CM, DM, EM 23 24 6,2
CR3-300-[ ] S, AM, BM, CM, DM, EM 27 27 6,8
CR3-400-[ ] S, AM, BM, CM, DM, EM 33 30 7,4

MOUNTING OPTIONS MOUNTING HARDWARE


S A(M) Countersunk
B(M) Countersunk IMPERIAL METRIC
Thru Hole
Hole Hole #4-40 M3 (x 0,5)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 13 in.-lbs. (1,5 Nm)

Thru Hole Thru Hole


Countersunk Standard Materials & Finishes*
Hole
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Countersunk Retaining Bars: Aluminum Alloy, treated per
Threaded Threaded
Hole MIL-C-5541

Operating Temperature Range


-150ºF to 500ºF ( -100ºC to 260ºC )
Thru Hole Threaded Threaded

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

38 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 43

CR3 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1
1 1 CR3-100
2 CR3-200
3 CR3-300
4 CR3-400
2 2

3
4

1 KEY 1
1 CR3-100
2 CR3-200
2 3 CR3-300
4 CR3-400
2

3
4

1 KEY
1 CR3-100 1
2 CR3-200
3 CR3-300
4 CR3-400
2

4
3

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 39
CWR-coverNEW/RED 11/20/02 2:43 PM Page 44

CR4 Series
1.10
See (27,9) .20
Mounting (5,1)
Options

1.34
(34,0) W H

.37
(9,4)
View Rotated
90º CW for clarity
1.00
(25,4)

Notes: 1. Dimensions are in inches (mm). U.S. Patent 6,244,579


2. Top and Bottom Mount Bars are identical.

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (oz.)
OPTION [ ]
CR4-100-[ ] S, A, B, C, D, E 1.66 1.87 1.4
CR4-200-[ ] S, A, B, C, D, E 2.10 2.12 1.4
CR4-300-[ ] S, A, B, C, D, E 2.37 2.34 1.5
CR4-400-[ ] S, A, B, C, D, E 2.96 2.67 1.7

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR4-100-[ ] SM, AM, BM, CM, DM, EM 42 48 40
CR4-200-[ ] SM, AM, BM, CM, DM, EM 53 54 40
CR4-300-[ ] SM, AM, BM, CM, DM, EM 60 59 43
CR4-400-[ ] SM, AM, BM, CM, DM, EM 75 68 48

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) Countersunk IMPERIAL METRIC
Thru Hole Thru Hole
Hole #10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 40 in.-lbs. (7,5 Nm)

Countersunk Countersunk
Thru Hole
Hole Hole Standard Materials & Finishes*
C(M) E(M) Cable: Stranded 300 Series Stainless Steel
D(M)
Thru Hole Threaded Threaded Retaining Bars: Aluminum Alloy, treated per
MIL-C-5541

Operating Temperature Range


Threaded Threaded Countersunk -150ºF to 500ºF ( -100ºC to 260ºC )
Hole

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

40 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 45

CR4 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 CR4-100 1
1 2 CR4-200
3 CR4-300
4 CR4-400

2
2

3
4

1
KEY
1 CR4-100 1
2 CR4-200
3 CR4-300
4 CR4-400

2
2

3
3

KEY
1 CR4-100
1
2 CR4-200
3 CR4-300 1
4 CR4-400
2

2
3

4 3

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 41
CWR-coverNEW/RED 11/20/02 2:43 PM Page 46

CR5 Series
See 1.10 .20
Mounting (27,9) (5,1)
Options

1.38
(35,1) W H

.39
(9,9)
View Rotated
90º CW for clarity
1.00
(25,4)

Notes: 1. Dimensions are in inches (mm).


2. Top and Bottom Mount Bars are identical. U.S. Patent 6,244,579

Imperial
SPECIFY DIMENSIONS
W UNIT WEIGHT
MODEL NO. MOUNTING H
(in.) (in.) (oz.)
OPTION [ ]
CR5-100-[ ] S, A, B, C, D, E 1.60 1.89 1.6
CR5-200-[ ] S, A, B, C, D, E 2.09 2.13 1.7
CR5-300-[ ] S, A, B, C, D, E 2.36 2.32 1.8
CR5-400-[ ] S, A, B, C, D, E 2.99 2.64 2.0

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR5-100-[ ] SM, AM, BM, CM, DM, EM 41 48 45
CR5-200-[ ] SM, AM, BM, CM, DM, EM 53 54 48
CR5-300-[ ] SM, AM, BM, CM, DM, EM 60 59 51
CR5-400-[ ] SM, AM, BM, CM, DM, EM 76 67 57

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) Countersunk IMPERIAL METRIC
Thru Hole Thru Hole
Hole #10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 40 in.-lbs. (7,5 Nm)

Countersunk Countersunk
Thru Hole Hole Standard Materials & Finishes*
Hole
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded Threaded
MIL-C-5541

Operating Temperature Range


Threaded Countersunk -150ºF to 500ºF ( -100ºC to 260ºC )
Threaded
Hole

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

42 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 47

CR5 Series
Load vs. Deflection Load vs.
Natural Frequency

KEY
1 CR5-100
1 2 CR5-200
3 CR5-300
4 CR5-400 1

3
2

4
3

1 KEY
1 CR5-100
2 CR5-200
3 CR5-300 1
4 CR5-400

2
3

3
4

1 KEY
1 CR5-100
2 CR5-200
3 CR5-300
4 CR5-400 1
2

3
2

4 3

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 43
CWR-coverNEW/RED 11/20/02 2:43 PM Page 48

CR6 Series
See 1.10
(27,9) .20
Mounting (5,1)
Options

1.41
(35,8) W H

.40
(10,2)
View Rotated
90º CW for clarity
1.00
(25,4)

Notes: 1. Dimensions are in inches (mm). U.S. Patent 6,244,579


2. Top and Bottom Mount Bars are identical.

Imperial
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W
(in.) (oz.)
OPTION [ ] (in.)
CR6-100-[ ] S, A, B, C, D, E 1.83 2.11 2.0
CR6-200-[ ] S, A, B, C, D, E 2.15 2.31 2.2
CR6-300-[ ] S, A, B, C, D, E 2.51 2.50 2.3
CR6-400-[ ] S, A, B, C, D, E 3.09 2.86 2.6

Metric
SPECIFY DIMENSIONS
UNIT WEIGHT
MODEL NO. MOUNTING H W (g)
OPTION [ ] (mm) (mm)
CR6-100-[ ] SM, AM, BM, CM, DM, EM 47 54 57
CR6-200-[ ] SM, AM, BM, CM, DM, EM 55 59 62
CR6-300-[ ] SM, AM, BM, CM, DM, EM 64 64 65
CR6-400-[ ] SM, AM, BM, CM, DM, EM 79 73 74

MOUNTING OPTIONS MOUNTING HARDWARE


S(M) A(M) B(M) Countersunk IMPERIAL METRIC
Thru Hole Thru Hole
Hole #10-32 M6 (x 1,0)
82º COUNTERSINK 90º COUNTERSINK
Maximum recommended torque for
threaded bar is 40 in.-lbs. (7,5 Nm)

Countersunk Countersunk Standard Materials & Finishes*


Thru Hole Hole
Hole
Cable: Stranded 300 Series Stainless Steel
C(M) D(M) E(M) Retaining Bars: Aluminum Alloy, treated per
Thru Hole Threaded Threaded MIL-C-5541

Operating Temperature Range


Countersunk
-150ºF to 500ºF ( -100ºC to 260ºC )
Threaded Threaded
Hole

* Non-standard materials and finishes are available. Contact Enidine to meet your specific requirements.

44 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 49

CR6 Series
Load vs. Deflection Load vs.
Natural Frequency

1 KEY
1 CR6-100
2 CR6-200
3 CR6-300
2 4 CR6-400

3 1

4 2

KEY
1 CR6-100
1 2 CR6-200
3 CR6-300
4 CR6-400 1
2

2
3

3
4

KEY
1 CR6-100
1 2 CR6-200
3 CR6-300
4 CR6-400
2
1

3
2

4
3

Notes: A. Natural frequency curves based on 1G input.


B. Do not extrapolate plotted curves.
C. Keys apply to both Load vs. Deflection and Load vs. Natural Frequency curves.
Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 45
CWR-coverNEW/RED 11/20/02 2:43 PM Page 50

Application Worksheet
SIZING INSTRUCTIONS - VIBRATION ISOLATION SIZING INSTRUCTIONS - SHOCK ISOLATION
If the desired system natural frequency is known, refer to the appropriate Load Selecting appropriate isolators for shock is based on the Wire Rope Isolator’s
vs. Natural Frequency curves to determine the recommended Wire Rope or average stiffness at the required dynamic deflection (Dmin). Follow the steps
Compact Wire Rope Isolator model. If the preferred system natural frequency is below to achieve a recommended Wire Rope Isolator product selection.
unknown, follow the steps below to achieve a recommended Wire Rope Isolator
product selection. STEP 1: Fill out Part I and Part III of the Application Worksheet.

STEP 1: Fill out Part I and Part II of the Application Worksheet. STEP 2: Refer to the Load vs. Deflection curves for the desired loading
orientation. Locate curves capable of the Minimum Dynamic
STEP 2: Refer to the Load vs. Natural Frequency curves for the required Deflection (Dmin) calculated from the worksheet. Find a curve that
loading orientation. Use the System Natural Frequency (ƒn ) is on or slightly under the Average Force (Favg) at the Average
calculated from the worksheet to select the smallest Wire Rope
Isolator model capable of the static load (W). Deflection (davg) calculated from the worksheet.

STEP 3: Specify the required mounting option suffix to complete the part STEP 3: Specify the required mounting option suffix to complete the part
number. (Please refer to available mounting options as indicated on number. (Please refer to available mounting options as indicated on
each Wire Rope and Compact Wire Rope Isolator series data page.) each Wire Rope and Compact Wire Rope Isolator series data page.)

APPLICATION WORKSHEET - INPUTS IMPERIAL/METRIC


IMPERIAL METRIC
PART I: SYSTEM DATA:
1. Total Load ( WT): WT = ________ lbs.
WT = ________ Kg x 9.81 = ________ N
2. Number of Isolators (n): n = ________

3. Static Load per Isolator (W): W = WnT W = ________ lbs.* W = ________ N*


* Assumes a central CG
4. Load Axis: Compression Load Axis Load Axis
Shear or Roll
45º Compression/Roll ____________________ ___________________

PART II: VIBRATION SIZING:


1. Input Excitation Frequency (ƒi) = ________ Hz ( = rpm
60
)
ƒi
2. System Natural Frequency for 80% isolation: ƒn = ƒn = ________ Hz* ƒn = ________ Hz*
3.0
* The System Natural Frequency (ƒn ) must lie on a published curve.
The published natural frequencies are based on a 1G input condition.
Random Vibration inputs: Consult Enidine for recommendations.

PART III: SHOCK SIZING:


1. Maximum Allowable Transmitted G Load: (GT): ________G’s
2. Shock Input Velocity: (V) = ________ in./sec.2
________ m/sec.2

a) Free Fall Impact: g = 386 in./sec.2 or 9.81 m/sec.2


V = 2gh h = Drop Height (in. or m)
b) Half-Sine Acceleration Input: A0 = Peak Acceleration (G’s)
t0 = Duration (seconds)
V = 2 g A0 t0
π

Imperial Metric
2 2
V V
3. Min. Response Deflection: Dmin = Dmin = Dmin = ________in. Dmin = ________mm
g (GT – 1) g (GT – 1) 1000

2 2
4. Average Force: Favg = WV Favg WV Favg = ________lbs. Favg = ________N
=
2g Dmin 2g ( Dmin ) 1000

davg = Dmin davg = ________in. davg = ________mm


5. Average Deflection:
2
Ordering Information
Fax, phone, or mail your order to the nearest Enidine/distributor location, Attention: Sales Department (see back cover for listing of Enidine locations).
EXAMPLE:
20 WR8 or CR6 – 600-08 – * – [ ]
1. Select Quantity 2. WR or CR Series 3. Select Dash Number 4. Specify Mounting Option** 5. Select “M” For Metric Model
Specify Model Number
**Please refer to available mounting options as indicated on each WR and CR series data page.
If you have special requirements, send us your application and Enidine will contact you with recommendations for a solution.

46 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:43 PM Page 51

Sketches/Notes

Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909 47


CWR-coverNEW/RED 11/20/02 2:43 PM Page 52

Sketches/Notes

48 Internet: www.enidine.com Phone: 1-800-852-8508 Fax: 1-716-662-1909


CWR-coverNEW/RED 11/20/02 2:42 PM Page 4

Typical Compact Wire Rope Isolator Applications


CD-ROM
Drives Laboratory Centrifuges

Medical Ventilators

U.S. Patents 6,290,217


6,244,579

Computer
Hardware
Other Compact Wire Rope Isolator
Applications
• Audio/ Visual Equipment
• Avionics
• Catering Carts
• Communications Packages
• Medical Devices
• Sensitive Electronic Equipment
CWR-coverNEW/RED 11/20/02 2:41 PM Page 1

Enidine Incorporated Subsidiaries and Affiliates: Enidine Corporativo De Mexico,


7 Centre Drive S.A. de C.V.
Orchard Park, New York 14127 • USA Enidine West Av. Patria 3124-A
Phone: 716-662-1900 184 Technology Dr., Suite 201 Col El Sauz
Fax: 716-662-1909 Irvine, California 92618 • USA Guadalajara, CP
www.enidine.com Phone: 949-727-9112 Jalisco • Mexico 45080
Fax: 949-727-9107 Phone: 52 3 646-8100
www.enidine.com Fax: 52 3 646-6755
www.enidine.com.mx
Enidine GmbH
Rheinauenstr, 5 Enidine U.K. Ltd.
79415 Bad Bellingen Patrick Gregory Road
Rheinweiler • Germany Wolverhampton
Phone: 49 7635 8101 0 West Midlands, WV11 3DZ
Fax: 49 7635 8101 99 United Kingdom
www.enidine.de Phone: 44 1902 304000
Fax: 44 1902 305676
Enidine Co. Ltd. www.enidine.co.uk
398, Chigasaki-Cho, Tsuzuki-Ku
Yokohama-Shi, Kanagawa 224-0031
Japan
Phone: 81 45 947 1671
Fax: 81 45 945 3967
www.enidine.co.jp

ENIDINE PRODUCTS
Shock Absorbers • Rate Controls • Air Springs • One-Shot Emergency Stops
Elastomeric Isolators • Wire Rope Isolators • Compact Wire Rope Isolators • Heavy Industry Buffers
UltraLOC™ Seat Recline Controls • Stow Bin Actuators/Rate Controls • Interior Noise Isolators
Energy Absorption Devices • Rotary Actuators/Dampers • APU Isolators

Solutions in Energy Absorption and Vibration Isolation.


CGWRICMB 11/02 10M

You might also like