(t − t ) − (th2 − tc1)
θmc = θ1 − θ2 = h1 c2
θ
ln b l
1
ln b th1 − tc2 l
θ2 th2 − tc1
(80 − 30) − (50 − 40)
= = 40 = 28.85cC
ln b l
50 ln (5)
10
Now for defining the type of flow, we use the correction factor.
θm = Fθmc = Fθmp ...(i)
Where F = correction factor, which depends on the geometry of the heat
exchanger and the inlet and outlet temperatures of the of the hot and cold
streams.
GATE Previous Year Solved Paper For Mechanical Engineering
Published by: NODIA and COMPANY ISBN: 9788192276250
Visit us at: www.nodia.co.in
www.gatehelp.com
F < 1, for cross flow and F = 1, for counter and parallel flow
So, From equation (i),
F = θm = 26 = 0.90 < 1
θmc 28.85
and also F = θm = 26 = 1.04 > 1
θmp 24.85
So, cross flow in better for this problem.