Vent Calculation

The document contains flow rate data for various activities in a plant under maximum, minimum and normal conditions. It lists the reactor in operation, discharging of reactor, pressure release and vacuum pump as key activities along with their corresponding flow rates in m3/hr. It also provides safety margins for the minimum and normal conditions. Additionally, it includes basis data for discharging of reactor, pressure release and venting nozzle along with reaction conditions and vacuum pump specifications.

Uploaded by

niteshacharya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
314 views4 pages

Vent Calculation

The document contains flow rate data for various activities in a plant under maximum, minimum and normal conditions. It lists the reactor in operation, discharging of reactor, pressure release and vacuum pump as key activities along with their corresponding flow rates in m3/hr. It also provides safety margins for the minimum and normal conditions. Additionally, it includes basis data for discharging of reactor, pressure release and venting nozzle along with reaction conditions and vacuum pump specifications.

Uploaded by

niteshacharya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

MAXIMUM

Activity Unit Flow Rate m3/ hr


Reactor in Operation 18 2004
Discharging of reactor 3 4800
Release of pressure @ 1 Bar 3 540000
Vacuum Pump 4 1400
Total Flow Rate 548203.6

MINIMUM
Activity Unit Flow Rate m3/ hr
Reactor in Operation 6 668
Discharging of reactor 1 1600
Release of pressure @ 1 Bar 00
Vacuum Pump 1 350
Total Flow Rate 2617.9
Safety Margin 3141

NORMAL
Activity Unit Flow Rate m3/ hr
Reactor in Operation 10 1113
Discharging of reactor 1 1600
Release of pressure @ 1 Bar 00
Vacuum Pump 2 700
Total Flow Rate 3413.1
Safety Margin 4096
Activity Basis Unit
Discharging of reactor 1600 m3/ Hr
Release of pressure @ 1 Bar 180000 m3/ Hr
Velocity flow during reaction or ideal 350 FPM
Venting Nozzel
Volume flow sizereaction
during consideration
or ideal 150 mm
condition 111 m3/Hr
Vacuum Pump 350 m3/ Hr
DATA
batch discharging batch 1.1 kg pressure
time discharging pressure pressure release 0 pressure
date Dilutor start time end time start time time start time time
25/10/2019 lk 14 1800 kg 16200 kg 12:42 12:55
9:55 10:34

23/10/2019 Lk14 6:06 6:34


800 16188

18/10/2019 LK16 16:18 17:20


680 11835

24/10/2019 lk 16 1:23 1:25


1:19 1:56 3:51 3:56

initial After
P (atm) 1 2
V (L) 30000 2070.30050
30000
N (mole) 1035.150252 4
R (Latm/(K*mole) 0.0821 0.0821
T (K) 353 353
vaccume create time (-0.7) zero vaccume time
Int final Int final
0:13 7:59 8:20 1:49 1:57