Overturning Check
Width of base Bb = = 118.1 in 3,000 mm
Length of base Lb = = 118.1 in 3,000 mm
Width of pedestal Bp = = 70.9 in 1,800 mm
Length of pedestal Lp = = 70.9 in 1,800 mm
Height of soil above top of base hs = hp - 300 = 39.4 in 1,000 mm
Table 5-2,
Foundation
Analysis & Design,
Bowles, 5th Ed.
I1 = = 0.408 = 0.408
Influence factors Table 5-2, Bowles
I2 = = 0.037 = 0.037
Poisson's Ratio μ = = 0.3 = 0.3
REFERENCE COMPUTATION OUTPUT (imperial) OUTPUT (metric)
Foundation depth D = hs + h = 59.1 = 1,500 mm
Fig. 5-7,
Foundation
Analysis & Design,
Bowles, 5th Ed.
Consolidation Settlement
Sec. 10.6.2, 10481- Modulus of volume compressibility Mv = = 6.14E-05 m2/kN
BCL-AKGE-GT-REP-
0024 Vertical effective stress applied to the soil layer dp = = 111 kN/m2
Thickness of layer considered Hs = = 1.0 m
Consolidation settlement Sc = Mv x dp x Hs = 6.82 mm
Total Settlement
Total settlement St = Se + Sc = 16.68 mm
Allowable settlement Sall = = 25.00 mm
UC = 0.67 Settlement OK