Interscan's portable analyzers are available for Br2, CO, Cl2, ClO2, Single Point
• Continuous Monitor
C2H4, ethylene oxide, HCHO, H2, hydrazine, HBr, HCl, HCN, H2S, NO, Two Point
NO2, O3, propylene oxide, and SO2. • Automation Based G
Detection Systems
• Continuous Monitor
Three Or More Poi
Our portable analyzers utilize Interscan's own patented (US Patent • Arc-Max® Compute
Number 4,017,373) electrochemical voltammetric sensors. Data Acquisition S
• The Halimeter® Mea
Bad Breath Scienti
4000 Series Compact Portable Analyzers • Inexpensive, Accura
Nomad Data Logge
Features • Vikane® Monitor
Tech Center
• Common Specificati
z An integral sample pump, powered by • Ethylene Oxide
rechargeable Ni-Cd batteries (supplied), • FAQ - Instrument
giving up to 10 hours of continuous service Troubleshooting
• Gas Detection
Applications Prime
z Digital readout of concentration in real time
• Gas Detection
Knowledge Base
z Audible and visual alarm • General Considerati
• Getting Service
• How Do I Get Starte
z Nylon/Cordura carrying case
• Halimeter®
Click Here For Larger View • Interfering Gas Dat
z Plug-in "calculator-type" battery charger • Manual Downloads
• Material Safety Data
• PowerPoint Present
z UL Classified Intrinsically Safe models, • Schematics
for use in hazardous locations, Class I, • Sensor Principle of
Groups A, B, C, and D (10X0), are • Sensor Response Da
available. Please consult factory. • Software Download
• Toxnet - HSDB
z Analog output (0-100 mV f.s.) • Useful formulae--
Conversions, etc.
Industry Links
z CE Approved models available, please Interscan In The N
consult factory. • Magazine Articles
Representatives a
Options Additional Specs Distributors World
Special Interest Ite
z Special ranges Resolution • Mike's Comment
z Special packaging of the Week
• Cool Site of the Wee
0-1999 ppm range: 1 ppm Interscan Photo G
0-199.9 ppm range: 0.1ppm
Streaming Media L
0-19.99 ppm range: 0.01 ppm
E-mail Us
0-1999 ppb range: 1 ppb

Weight:

file://C:\Documents%20and%20Settings\mannj\My%20Documents\Interscan%20Corporat... 2/19/2005
Interscan Corporation - Portable / Survey Monitoring Applications Page 2 of 3

Send us your e-mail ad


4.5 lb (2.0 kg) to receive our informat
and fun newsletter.
Dimensions:
7" H x 4" W x 8.875" D
E-mail
(178 x 102 x 225 mm)
Name
Specifications common to all Interscan gas
detection instruments i Subsc
j
k
l
m
n
j Unsub
k
l
m
n

S
Range Table and Ordering Information for 4000 Series
Portable Analyzers

STANDARD LOWEST RANGE


MODEL MEASURING RANGES Available on special
GAS order
NO. (ppm, unless otherwise
indicated) (ppm, unless otherwise
indicated)

Br2 4700-0 0-1999


bromine 4700-1 0-199.9 0-1999 ppb
4700-2 0-19.99
CO 4140-0 0-1999
carbon 4140-1 0-199.9 0-20
monoxide 4140-2 0-19.99
Cl2 4340-0 0-1999
chlorine 4340-1 0-199.9 0-1999 ppb
4340-2 0-19.99
ClO2 4330-0 0-1999
chlorine 4330-1 0-199.9 0-1000 ppb
dioxide 4330-2 0-19.99
C2H4 4070-0 0-1999
ethylene 4070-1 0-199.9 0-5
4070-2 0-19.99
EtO 4200-0 0-1999
ethylene oxide 4200-1 0-199.9 0-1999 ppb
4200-2 0-19.99
HCHO 4160-0 0-1999
formaldehyde 4160-1 0-199.9 0-500 ppb
4160-2 0-19.99
H2NNH2 4180-0 0-1999
CH3NHNH2 4180-1 0-199.9
(CH3)2NNH2 4180-2 0-19.99
hydrazine(s) ¶ 4180-3 0-1999 ppb
0-100 ppb
4183¤ 0-0.5/0-2
4186¤ 0-2/0-10
4187¤ 0-100/0-2000 ppb
4189¤ 0-100/0-1000 ppb
H2 4020-0 0-1999
0-100
hydrogen 4020-1 0-199.9
HBr
4800-0 0-1999

file://C:\Documents%20and%20Settings\mannj\My%20Documents\Interscan%20Corporat... 2/19/2005
Interscan Corporation - Portable / Survey Monitoring Applications Page 3 of 3

hydrogen 4800-1 0-199.9


0-1999 ppb
bromide 4800-2 0-19.99
HCl 4360-0 0-1999
hydrogen 4360-1 0-199.9 0-1999 ppb
chloride 4360-2 0-19.99
HCN 4280-0 0-1999
hydrogen 4280-1 0-199.9 0-1999 ppb
cyanide 4280-2 0-19.99
H2S 4170-0 0-1999
hydrogen 4170-1 0-199.9
0-500 ppb
sulfide 4170-2 0-19.99
4170-3 0-1999 ppb
NO 4540-0 0-1999
nitric oxide 4540-1 0-199.9 0-1999 ppb
4540-2 0-19.99
NO2 4150-0 0-1999
nitrogen 4150-1 0-199.9
dioxide 4150-2 0-19.99 0-1999 ppb
Also known as N2O4 4152¤ 0-2/10
nitrogen tetroxide
4154¤ 0-10/0-50
O3 4480-0 0-1999
ozone 4480-1 0-199.9 0-1999 ppb
4480-2 0-19.99
PrO 4320-0 0-1999
propylene 4320-1 0-199.9 0-1000 ppb
oxide 4320-2 0-19.99
SO2 4240-0 0-1999
sulfur dioxide 4240-1 0-199.9 0-1999 ppb
4240-2 0-19.99

¶ There is not a separate analyzer available for each of these compounds, and the sensor does not respond
equally to all hydrazine species. The analyzer must be calibrated with the specific hydrazine compound of
interest.

¤ Indicates the analog meter UL classified intrinsically safe version, which must be ordered in most hypergol
monitoring applications.

P.O. Box 2496 • Chatsworth, CA 91313-2496


TOLL FREE: (800) 458-6153 (US & Canada) • PHONE: (818) 882-2331
FAX: (818) 341-0642 • E-MAIL: [email protected]

file://C:\Documents%20and%20Settings\mannj\My%20Documents\Interscan%20Corporat... 2/19/2005

You might also like