32 TiNet+GL8600-04+Installation+Manual PDF
32 TiNet+GL8600-04+Installation+Manual PDF
32 TiNet+GL8600-04+Installation+Manual PDF
User Manual
1. Product Description
2. Specifications and Characteristics
3. Preparation Before Installation
4. Installation
5. Startup and Configuration
6. Software Upgrade
7. Troubleshooting
8. Optional Interface Modules
9. Appendix RJ-45 Connector
Shenzhen New Greennet Technologies Co., Ltd. Contents
Contents
Chapter 4 Installation............................................................................................................................4-1
4.1 Mechanical Installation............................................................................................................. 4-1
4.1.1 Installing the Device in a Cabinet................................................................................4-1
4.1.2 Installing the Device onto a Workbench.................................................................... 4-2
4.2 Connection of Power Cables and Ground Cables...............................................................4-3
I
Shenzhen New Greennet Technologies Co., Ltd. Contents
4.2.1 AC Power Supply and Installation...............................................................................4-3
4.2.2 DC Power Supply Installation...................................................................................... 4-3
4.2.3 Installing the Ground Cable......................................................................................... 4-4
4.3 Connecting the Console Cable............................................................................................... 4-4
4.3.1 Installing the Console Cable........................................................................................ 4-4
4.3.2 Connecting the Console Cable....................................................................................4-5
4.4 Check after Installation.............................................................................................................4-5
II
Shenzhen New Greennet Technologies Co., Ltd.
1
Shenzhen New Greennet Technologies Co., Ltd.
2
Shenzhen New Greennet Technologies Co., Ltd.
2.1 Appearance
1
Shenzhen New Greennet Technologies Co., Ltd.
Slots 2-5 - house four NG01PG08MAs (OLT service board) or
NG01GT24MAs with Gigabit uplink electrical ports
The panel of a control board of the TiNet S8600-04 GPON OLT is as shown
below:
The panel provides several LED indicators, a USB backup port, an RS232
serial console port (marked CONSOLE), a port for management (marked
AUX), and a port for remote login.
Front panel LED indicators are explained as given in Table 2-1:
Table 2-1 Meanings of LED indicators on the front panel of a control board of TiNet
S8600-04 GPON OLT
Sign on
Indicator the Front Status Meaning
Panel
Flashing The OLT is running properly.
RUN Always
The OLT malfunctions.
ON or OFF
Always
ON
FAU
System status Always
indicators OFF
Always On The current control board is running.
ACT Always
Backup main control panel status
OFF
On The power supply is normal.
PWR
Off A power supply failure occurs.
2
Shenzhen New Greennet Technologies Co., Ltd.
Sign on
Indicator the Front Status Meaning
Panel
Always on The power module can be detected.
PWR in-position PRES Always The power module slot is vacant or the
OFF power module is faulty.
Always on The power module is operating normally.
OK Always The power module slot is vacant or the
OFF power module is faulty.
Always on The slot has a line board.
PRES Always
The slot does not have a line board.
OFF
Always on The slot is operating normally.
SLOT status
ACT Always The slot is faulty or does not have a
indicators
OFF board.
Always on The slot is faulty.
FAU Always
The slot is operating normally.
OFF
The front panel layout of a line board of TiNet S8600-04 GPON OLT is as
shown below:
The panel provides eight 1000 Base-x SFP uplink ports GE1 ~ GE8, eight
GPON OLT SFP ports GP1 ~ GP8, one RS232 Console port, one port for
commissioning AUX. The LED indicators are explained as given in Table 2-1:
3
Shenzhen New Greennet Technologies Co., Ltd.
Table 2-2 Indicators on the front panel of a line board of TiNet S8600-04 GPON OLT
Sign on the
Indicator Front Status Meaning
Panel
On The board is operating under normal voltage.
Power
PWR The board is operating under abnormal
indicator Off
voltage.
Single panel Blinking The CPU of the board is normal.
running RUN
Off The CPU of the board is abnormal.
indicator
The AUX port is connected improperly or
Off
Indicator for unconnected.
the port for AUX On The AUX port is connected properly.
commissioning The AUX port is connected properly and is
Flashing
transmitting data.
The GE port is connected improperly or
Off
unconnected.
GE status
GE On The GE port is connected properly.
indicator
The AUX port is connected properly and is
Flashing
transmitting data.
Off No ONU is registered with the PON port.
There is at least one ONU registered with the
GPON status On
GP PON port.
indicator
The PON port has registered ONUs and is
Flashing
transmitting data.
4
Shenzhen New Greennet Technologies Co., Ltd.
Table 2-3 Optional modules for GPON OLT SFP interface
Connector Maximum
Center of the Fiber Transmission
SFP Module
Wavelength Optical Specifications Distance of
Cable Optical Fibers
1310 nm in
Single-mode
SFP-GPON-LH10 receiving, 1550 10km
fiber
nm in sending
LC
1310 nm in
Single-mode
SFP-GPON-LH20 receiving, 1550 20km
fiber
nm in sending
Connector Maximum
Center of the Fiber Transmission
SFP Module
Wavelength Optical Specifications Distance of
Cable Optical Fibers
Multimode
SFP-GE-SX-MM850 850 nm 550m
fiber
SFP-GE-SM1310-LH10 10km
SFP-GE-SM1310-LH20 1310 nm LC 20km
Single-mode
SFP-GE-SM1310-LH40 40km
fiber
SFP-GE-SM1550-LH40 40km
1550 nm
SFP-GE-SM1550-LH60 60km
Gigabit SFP modules may be updated from time to time. Consult the
marketing staff of New Greennet for latest module information.
5
Shenzhen New Greennet Technologies Co., Ltd.
2.3 Rear Panel of TiNet S8600-04 GPON OLT
6
Shenzhen New Greennet Technologies Co., Ltd.
2.4 System Characteristics
7
Shenzhen New Greennet Technologies Co., Ltd.
Item TiNet S8600-04 GPON OLT
The transmission distance of each OLT is up to 20Km
VLAN, QinQ, link aggregation, Broadcast storm control
L2 functions
Supports up to 4096 VLANs;
L3 multicast: IGMPv1/v2/v3, PIM-DM, PIM-SM, support for 1K L3
multicast routing tables
Multicast L2 Multicast: IGMPv2 in RFC 2236, IGMPv3 in RFC 3376, IGMP
Filter, IGMP Fast leave, controllable multicast, inter-VLAN
multicast replication, support for 1K L2 multicast groups
Supports standard and extended ACLs. A maximum of 2K to 6K
ACL rules can be effective simultaneously.
Supports Time-Range-based ACL policy
Provides flow classification and flow definition based on such IP
packet header information as source/destination MAC address,
VLAN, 802.1p, ToS, DiffServ, source/destination IP (IPv4/IPv6)
address, TCP/UDP port number, and protocol type. The system
can identify a maximum of 2 K service flows concurrently.
Supports L2 ~ L7 and packet filtering 80 bytes further in IP packet
header.
Supports rate limitation by port or flow on packets receiving and
sending, and provides ordinary traffic policing and two-rate
ACL/QOS
three-color traffic policing on flows.
Supports priority marking by port or flow, and provides the priority
Remark function based on 802.1P and DSCP.
Supports Committed Access Rate (CAR), Traffic shaping and
traffic statistics.
Supports packet mirroring and packet redirection by port or flow
Supports advanced queue scheduling based on ports and flows.
Each port or flow can be configured with at most eight priority
queues, where queue scheduling algorithms such as SP, WRR,
and SP + WRR are applied.
Supports congestion avoidance mechanisms such as Tail-Drop
and WRED.
8
Shenzhen New Greennet Technologies Co., Ltd.
Item TiNet S8600-04 GPON OLT
Supports automatic display of the source MAC address of the host
that launches an attack, and automatic binding of IP and MAC
addresses, to prevent the ARP tables of normal users from being
tampered in ARP spoofing and gateway IP addresses from being
forged in ARP attacks.
The ARP traffic of each user can be limited and users with
abnormal ARP traffic may be automatically blacklisted.
Supports effective protection against various DOS attacks (such
as ARP attack, Synflood attack, Smurf attack, ICMP attack), ARP
monitoring, network worms and Blaster virus attack.
Supports port trust functions to detect illegitimate DHCP servers
and Radius servers.
Supports Unicast Reverse Path check (URPF), which can
effectively prevent IP address forgery and attacks.
Supports ACL-based flow filtering.
Supports IEEE 802.1x and AAA/Radius authentication.
Security Features Enables users to bind IP addresses, VLAN IDs, MAC addresses
and port numbers.
Supports DHCP Option82, and PPPoE + so that the physical
location information of users can be uploaded.
Supports plaintext authentication of OSPF, RIPv2 and BGPv4
packets and MD5 ciphertext authentication.
Supports IP Source Guard, guaranteeing DHCP service security.
Supports RFC3176 sFlow traffic analysis, achieving protocol or
address-based traffic monitoring and statistics.
Supports broadcast packet suppression.
Supports data logging and RFC 3164 BSD syslog Protocol.
Supports SSHv2 Secure Shell.
Supports login through Telnet of Security IP and password-based
login.
Supports hierarchical user protection to prevent intrusion from
unauthorized users, and grants different levels of users different
configuration rights.
9
Shenzhen New Greennet Technologies Co., Ltd.
Item TiNet S8600-04 GPON OLT
Supports HSRP and VRRP.
Supports BFD, FlexLink L2 link backup, LACP, enhanced STP
(healing time is less than 1s), GERP (healing time is less than 50
ms) and other link fault recovery and redundancy mechanisms.
Reliability
Both host programs and configuration files are able to recover from
faults.
Boards are hot swappable.
Supports 1 +1 power supply hot backup.
Operating
0oC~45oC
Temperature
Operating
10%~90%
Humidity
10
Shenzhen New Greennet Technologies Co., Ltd.
1
Shenzhen New Greennet Technologies Co., Ltd.
The cabinet or workbench is correctly grounded.
To ensure normal operation of the device and prolong its service life, the
installation site should also meet the following requirements.
3.2.1 Temperature/Humidity
Constant temperature and humidity should be maintained inside the machine
room. If the machine room is kept humid inside in a long time, symptoms,
such as poor insulation and even electric leakage of insulating materials,
mechanical property degradation, and corrosion of metal parts, may occur.
Low relative humidity would cause fastening screws to loosen due to
shrinkage of insulation washers. Furthermore, in a dry climate, it is easy to
produce static electricity, endangering the CMOS circuit on the device. High
temperature greatly reduces device reliability and even shortens its service
life in a long term. Long-term exposure to a high temperature will accelerate
the aging of insulating materials.
3.2.2 Cleanliness
Dust is a hazard to safe operation of the device. The dust accumulated on the
chassis can cause electrostatic adsorption, leading to poor contact of metal
connectors or contact points. The electrostatic adsorption is more likely to
take place especially in a low-humidity indoor environment, which will affect
the device’s service life and cause communication failures as well.
Table 3-1 describes the requirements for dust concentration and diameter
inside the machine room.
Table 3-1 Requirements for dust concentration inside the machine room
2
Shenzhen New Greennet Technologies Co., Ltd.
Besides dust, the machine room housing device is also sensitive to salts,
acids, and sulfides contained in the air. These harmful gases can accelerate
the corrosion of metal parts and aging of certain parts. The machine room
should be free of harmful gases such as SO2, H2S, NO2, NH3, Cl2. See Table
3-2 for specific limits.
Average Concentration
Gas Maximum Concentration (mg/m3)
(mg/m3)
SO2 0.2 1.5
H2S 0 0.03
NO2 0.04 0.15
NH3 0.05 0.15
Cl2 0 0.3
3
Shenzhen New Greennet Technologies Co., Ltd.
3.3 Installation Tools and Devices
Required tools
Slot type screwdriver
Phillips screwdriver
Anti-ESD wrist strap
Cables
Power cable
Console cable
Ethernet cable
Required device
Terminal for configuration (or a PC)
Installation tools are not delivered with TiNet S8600-04 GPON OLT
but prepared by users themselves.
4
Shenzhen New Greennet Technologies Co., Ltd.
Chapter 4 Installation
1
Shenzhen New Greennet Technologies Co., Ltd.
The angle bars of the device are not used for load bearing but for
fixing the device. When installed in a cabinet, the device chassis must have
guide rails (fixed to the rack) on its bottom to support the device.
2
Shenzhen New Greennet Technologies Co., Ltd.
4.2 Connection of Power Cables and Ground Cables
TiNet S8600-04 GPON OLT is powered by hot swappable power supply box.
It supports both AC and DC hybrid-powered mutual backup mode.
Power supply box falls into two types, respectively AC and DC power supply,
with power supply voltage ranges
AC 176V~ 264V
DC –36V~–72V
3
Shenzhen New Greennet Technologies Co., Ltd.
4.2.3 Installing the Ground Cable
4
Shenzhen New Greennet Technologies Co., Ltd.
Table 4-1 Console cable connection
5
Shenzhen New Greennet Technologies Co., Ltd.
1
Shenzhen New Greennet Technologies Co., Ltd.
rate is "9600", data bit "8", parity check "none", stop bit "1", flow control "none",
and select "auto detection" for terminal simulation. Specific methods are as
follows:
Choose Start > Programs > Accessories > Communication > HyperTerminal
to establish a new connection. The system displays a Connection
Description dialog box, as shown in Figure 5-1. In the Name text box, input a
new name, such as GPON.
Click OK. The Connect to dialog box pops up, as shown in Figure 5-2. Select
a serial port from the Use in Connecting drop-down list.
2
Shenzhen New Greennet Technologies Co., Ltd.
Click OK. A dialog box pops up, as shown in Figure 5-3. In this dialog box, set
the baud rate to 9600, data bit to 8, parity check to None, stop bit to 1, and
flow control to None.
3
Shenzhen New Greennet Technologies Co., Ltd.
You can also click Configure on the HyperTerminal attribute interface to set
the serial port attributes, as shown in Figure 5-4:
4
Shenzhen New Greennet Technologies Co., Ltd.
Figure 5-4 Setting of serial port used In HyperTerminal connection in the attribute setting
window
5
Shenzhen New Greennet Technologies Co., Ltd.
6
Shenzhen New Greennet Technologies Co., Ltd.
7
Shenzhen New Greennet Technologies Co., Ltd.
5.2.2 Powering On the Device
When the device is powered on, startup information will be displayed on the
terminal. When the following prompt pops up,
User name(4-15 chars):
You can type a user name, press Enter, and you will be prompted to type
a password, as follows:
Password (1-15 chars):
After typing the password, the HyperTerminal prints the following
information:
QTECH>
At this time, users can view or configure device system information under
their permission.
8
Shenzhen New Greennet Technologies Co., Ltd.
1
Shenzhen New Greennet Technologies Co., Ltd.
2
Shenzhen New Greennet Technologies Co., Ltd.
Chapter 7 Troubleshooting
1
Shenzhen New Greennet Technologies Co., Ltd.
7.2.2 Garbled Characters
If garbled characters are displayed on the configuration terminal, a terminal
(such as a HyperTerminal) may encounter a setting error. Check and verify
that the terminal (such as a HyperTerminal) parameter settings are as follows:
Baud rate: 9600
Data bit: 8
Parity check: none
Stop bit: 1
Flow control: none
Auto detection for terminal simulation.
2
OptiWay GL5600-08P V100R001 Cassette OLT Installation Manual V1.0 (20130419) Installation Manual
3
OptiWay GL5600-08P V100R001 Cassette OLT Installation Manual V1.0 (20130419) Installation Manual
10/100Base-T 1000Base-T
Pin No.
Signal Function Signal Function
1 Tx+ Sending data BIDA+ A-direction data
2 Tx- Sending data BIDA- A-direction data
3 Rx+ Receiving data BIDB+ B-direction data
4 Reserved - BIDB- B-direction data
5 Reserved - BIDC+ C-direction data
6 Rx- Receiving data BIDC- C-direction data
7 Reserved - BIDD+ D-direction data
8 Reserved - BIDD- D-direction data
10/100Base-T 1000Base-T
Pin No.
Signal Function Signal Function
1 Rx+ Receiving data BIDB+ B-direction data
2 Rx- Receiving data BIDB- B-direction data
4
OptiWay GL5600-08P V100R001 Cassette OLT Installation Manual V1.0 (20130419) Installation Manual
10/100Base-T 1000Base-T
Pin No.
Signal Function Signal Function
3 Tx+ Sending data BIDA+ A-direction data
4 Reserved - BIDC+ C-direction data
5 Reserved - BIDC- C-direction data
6 Tx- Sending data BIDA- A-direction data
7 Reserved - BIDD+ D-direction data
8 Reserved - BIDD- D-direction data
5
OptiWay GL5600-08P V100R001 Cassette OLT Installation Manual V1.0 (20130419) Installation Manual
Wires of a straight-through cable and a crossover cable are arranged
respectively as follows. Users may select a cable type according to their own
needs. In a traditional network, a straight-through cable connects a network
adapter and a hub or device, while a crossover cable connects device or a
device and a hub or router. "SIDE1" and "SIDE2" in the figure represent the
two ends of a cable, and numbers 1 to 8 indicate the eight pins of an RJ-45
connector.
6
OptiWay GL5600-08P V100R001 Cassette OLT Installation Manual V1.0 (20130419) Installation Manual