High Vibration of GA-101D

The document discusses high vibration issues found in GA-101D quench oil pump. Vibration analysis showed the highest vibration occurs at the motor outer bearing axial side, over the danger level, while the pump side is in the good level. The dominant frequency was found to be 6975 cycles per minute (CPM), which equals the blade pass frequency (BPF) of 7 times the pump RPM. Further analysis was recommended, including a motor solo run, bump test, soft foot check, and alignment check. The shutdown activities found the motor bearing temperature was initially high, but a re-solo run showed the temperature went back to normal. Further tests like end play check, cold alignment, and hot alignment were recommended

Uploaded by

Habibie Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
195 views17 pages

High Vibration of GA-101D

The document discusses high vibration issues found in GA-101D quench oil pump. Vibration analysis showed the highest vibration occurs at the motor outer bearing axial side, over the danger level, while the pump side is in the good level. The dominant frequency was found to be 6975 cycles per minute (CPM), which equals the blade pass frequency (BPF) of 7 times the pump RPM. Further analysis was recommended, including a motor solo run, bump test, soft foot check, and alignment check. The shutdown activities found the motor bearing temperature was initially high, but a re-solo run showed the temperature went back to normal. Further tests like end play check, cold alignment, and hot alignment were recommended

Uploaded by

Habibie Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

High Vibration

GA-101D Quench Oil Pump D


Prepared by:
GA-101D Task Force Team
Vibration Trend

GA-101D Vibration

TAM 2019
12

10
Vibration (mm/s)

8
Motor
6 Pump
Alert
4 Danger

2
Motor Solo Run

0
22-Sep-2017 10-Apr-2018 27-Oct-2018 15-May-2019 1-Dec-2019 18-Jun-2020
Vibration Analysis

 Highest vibration occurs at Motor OB Axial side, over than DANGER level, while pump side is still belonged to
GOOD level
 Vibration spectrum shows 6975 CPM or 7x as dominant frequency.
Vibration (mm/s)
V H A
Motor OB 3.7 1.4 9.9
Motor IB 1.7 1.2 5.4
Vibration Analysis

 7x RPM is equal to Blade Pass Frequency (BPF) which is generated by the pump

High vibration location,


MOTOR at axial direction
GA-101D-M
Vibration Transmitted to Motor
PUMP
GA-101D
2.9 mm/s 9.9 mm/s

BPF is transmitted and amplified so that the value is bigger


Vibration Analysis
Only this part (end cover) is in high
Motor End Cover NDE side
vibration, other part vibration is low
Why-Why Analysis
Problem W1 W2 W3 W4 Point of Check PIC Result Possibility Remark

Natural frequency
is actually close to Manufature result Bump Test PdM-R - TBC Need shutdown
BPF
Check for
Mass changing modification MOE Motor has never been modificated Low
history
Resonance with
Coupling Stress
Natural Check Alignment MOM - TBC Need shutdown
Natural frequency (Misalignment)
Frequency
shifting to be
close to BPF Stiffness changing
due to residual Motor Soft foot Check soft foot MOM - TBC Need shutdown
stress
BPF is transmitted and
Pump End Play
amplificated from 3.1
over than Check End play MOM TBC Need shutdown
mm/s (at pump) to 7.1
tollerance
mm/s at GA-101D-M
1. Weak pedestal should generate horizontal vibration
Check Vibration
Weak Pedestal Design PdM-R 2. Pedestal design of GA-101D and GA-101B/C are the Low
Check pedestal
Motor Structural same, it should be OK
Problem
Pedestal Visual Check the
PdM-R No damage found at pedestal Low
crack/damage base plate

Check Endcover will be checked by


End cover loose MOE TBC
condition Electric Team

Bearing defect will generate harmonic vibration at


Bearing defect Vibration PdM-R radial direction, but actual is 7x at axial direction so that Low
bearing condition is still GOOD
RECOMMENDATION

Based on analysis, it is recommended to stop the pump and do following action:


• Motor Solo Run (MTN Electric)
• Bump test (PdM-Rotating)
• Check soft foot, alignment and Re-alignment if needed (MTN Rotating)
• Check End Play
Shutdown Activity
Result
1 - 8 May 2020
Activity Summary

1 May 10.00 GA-101D was turned off


1 May 10.30 – 11.00 Initial bump test (before coupling disconnected), results bad data
1 May 13.00 – 14.00 Disconnect coupling and alignment reading
1 May 14.30 Start Solo Run
1 May 14.50 – 15.10 While motor running, bump test was performed, then soft foot check by loosen
1 tie down bolt, check vibration and bump test
1 May 15.10 High motor bearing temperature DE side was found high, 108°C, all activity was
stopped waiting for further discussion
2 May 10.00 – 11.00 Re-solo run for 1 hour, bearing temperature IB side normal at 56°C
3 May End Play Check and Cold Alignment
8 May Hot Alignment and MRT
Reference:
Result BPF = 7xrpm = 7x990 rpm = 6930 cpm ± 10% = 6237 ~ 7623 cpm
Natural Frequency is not acceptable when it is between the range above

1. Initial Bump Test (1 May 2020)


Motor OB Motor IB
Condition Remark
Natural Freq. Result Natural Freq. Result
Bump test data is not good enough, when equipment stopped
After pump stopped, before
9506 cpm Acceptable 5988 cpm Acceptable rotor position was at bottom of sleeve bearing, possibly causing
coupling disconnected
damping effect to the bump test, need bump test when running

Rotor position during off Rotor position during running


Bearing TOP Bearing Bearing TOP Bearing

ROTOR ROTOR
Friction at this area
causing bump test BOTTOM BOTTOM
result inaccurate
Reference:
Result BPF = 7xrpm = 7x990 rpm = 6930 cpm ± 10% = 6237 ~ 7623 cpm
Natural Frequency is not acceptable when it is between the range above
2. Bump test during motor solo run (2 May 2020)

Motor OB Motor IB Vibration OB Vibration IB


No Condition Natural Remark
Result Natural Freq. Result V H A V H A
Freq.
1 Initial, all bolt tight 6952 cpm Not Acceptable 5996 cpm Acceptable 0.1 0.1 0.2 0.2 0.3 0.6 Bearing temp: OB 46°C, IB 58°C
2 Loosen tie down bolt No 4 6963 cpm Not Acceptable 5990 cpm Acceptable
3 Loosen tie down bolt No 3 6991 cpm Not Acceptable 5983 cpm Acceptable 0.2 0.2 0.2 0.2 0.3 0.5
4 Loosen tie down bolt No 2 6924 cpm Not Acceptable 5988 cpm Acceptable 0.1 0.2 0.2 0.3 0.5 0.5 High bearing temp: OB 52°C, IB 106°C
5 Loosen tie down bolt No 1 Canceled due to high bearing temp

PUMP SIDE
3. Re-Solo run (2 May 2020)

Measured Vibration OB Vibration IB 1 2


Condition Remark
after V H A V H A
Re-solo Run after lube oil replaced 10 min 0.1 0.2 0.2 0.2 0.3 0.6 Bearing temp after 1 hour running:
with the fresh oil and all tie down
OB 46°C, IB 58°C
MOTOR
bolt tightened 45 min 0.1 0.2 0.2 0.2 0.3 0.7

Re-Solo Run result is GOOD


Top View
4 3
Result
4. Alignment and Endplay Check

Alignment, DBSE and End Play are still in tolerance

5. Vibration Measurement during Start Up (8 May 2020)


Vibration (m/s)
Motor OB Motor IB Pump IB Pump OB
V H A V H A V H A V H A
2.7 1.0 7.2 1.1 1.0 4.5 2.8 2.2 1.4 3.1 2.0 1.1
Remark: Vibration is still high after start up
Analysis
1. High Bearing Temperature when tie down bolt is loosened
Suspect: High bearing temperature is generated by motor shaft touch the sleeve bearing

Initial – all bolts tight


Harmonic frequency
appeared as effect
of a periodic impact Loosen tie down bolt No 3
suspected between
shaft and sleeve
bearing Loosen tie down bolt No 2

Re-Solo run – all bolts tight

Bolt loosening → bearing centering changed → shaft and sleeve touching → high bearing temperature.

This phenomenon also proved that soft foot is low possibility to be occurred
(because soft foot will also generate high bearing temperature during normal running)
Reference:
Analysis BPF = 7xrpm = 7x990 rpm = 6930 cpm ± 10% = 6237 ~ 7623 cpm
Natural Frequency is not acceptable when it is between the range above

2. Bump Test Result

Motor OB
Summary:
No Condition Natural 1. Natural frequency is too close to BPF, high possibility to
Result
Freq. generate resonance problem
1 Initial, all bolt tight 6952 cpm Not Acceptable 2. Natural frequency is not significantly affected when bolt
2 Loosen tie down bolt No 4 6963 cpm Not Acceptable is loosened, low possibility of soft foot
3 Loosen tie down bolt No 3 6991 cpm Not Acceptable
4 Loosen tie down bolt No 2 6924 cpm Not Acceptable

Blade Pass Frequency Resonance with


(low vibration)
Transmitted
natural Frequency High Vibration
Reference:
Bump Test Spectrum BPF = 7xrpm = 7x990 rpm = 6930 cpm ± 10% = 6237 ~ 7623 cpm
Natural Frequency is not acceptable when it is between the range above
Why-Why Analysis - Updated
Problem W1 W2 W3 W4 Point of Check PIC Result Possibility CA

Natural frequency
natural frequency is close to BPF (in range 10%), high possibility to Need study to shift the natural frequency
is actually close to Manufature result Bump Test PdM-R High
resonance to be more than ±10% of BPF
BPF

Check for
Mass changing MOE Motor has never been modificated Low
modification history

Resonance with
Coupling Stress Temp : 140 (bot) 115 (top), -28/-4 DBSE:203.40 (Acceptable)
Natural Check Alignment MOM Low
Natural frequency (Misalignment) Standar temp 120-140 : Radial -20 ~ -30 , Axial: -10
Frequency
shifting to be
close to BPF Stiffness changing Natural frequency was not significantly changed when bolt loosened.
due to residual Motor Soft foot Check soft foot MOM Motor bearing temperature is high when bolt loosen, so that motor Low
stress base is flat.
BPF is transmitted and
Pump End Play
amplificated from 3.1
over than Check End play MOM 0.01 mm (maks 0.05 mm) Low
mm/s (at pump) to 7.1
tollerance
mm/s at GA-101D-M
1. Weak pedestal should generate horizontal vibration
Check Vibration
Weak Pedestal Design PdM-R 2. Pedestal design of GA-101D and GA-101B/C are the same, it should Low
Check pedestal
Motor Structural be OK
Problem
Pedestal Visual Check the
PdM-R No damage found at pedestal Low
crack/damage base plate

Check Endcover
End cover loose MOE End Cover bolts tight Low
condition

Bearing defect will generate harmonic vibration at radial direction, but


Bearing defect Vibration PdM-R Low
actual is 7x at axial direction so that bearing condition is still GOOD
THANK YOU