0% found this document useful (0 votes)
99 views4 pages

SCT-1100 and SCT-2200 Advanced Series: Approvals Approvals

The document describes two advanced series signal conditioning transmitter/indicator models, the SCT-1100 and SCT-2200. The SCT-1100 has analog output capabilities while the SCT-2200 uses EtherNet/IP fieldbus communication. Both models have high resolution AD conversion, digital and analog I/O, display and interface options, and are designed for industrial weighing and process control applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views4 pages

SCT-1100 and SCT-2200 Advanced Series: Approvals Approvals

The document describes two advanced series signal conditioning transmitter/indicator models, the SCT-1100 and SCT-2200. The SCT-1100 has analog output capabilities while the SCT-2200 uses EtherNet/IP fieldbus communication. Both models have high resolution AD conversion, digital and analog I/O, display and interface options, and are designed for industrial weighing and process control applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SCT-1100 and SCT-2200 Advanced Series

Signal Conditioning Transmitter/Indicator


INDICATORS / CONTROLLERS

APPROVALS APPROVALS
SCT1100-AN with Analog Output SCT2200 with EtherNet/IP Fieldbus Module

SCT-1100 Specifications SCT-2200 Specifications


12/24 VDC, 12/24 VDC,
Power
Power Consumption: 70 mA min – 100 mA max Power Consumption: 70 mA min – 100 mA max
Excitation Voltage 5VDC, 120 mA, 8 x 350 Ω 5 VDC, 120 mA, 8 x 350 Ω
Analog Signal Input Range ± 39 mV ± 39 mV
0.03 µV/graduation minimum 0.03 µV/graduation minimum
Analog Signal Sensitivity
0.3 µV/graduation recommended 0.3 µV/graduation recommended
Four channel A/D 24-bit sigma-delta conversion, One channel A/D 24-bit sigma-delta conversion,
A/D Sample Rate
up to 200 conv. /sec. auto select up to 200 conv. /sec. auto select
Internal resolution: 1.5 million counts Internal resolution: 1.5 million counts
Resolution
Weight display resolution: 800,000 minimum Weight display resolution: 800,000 minimum
Two inputs: 12/24 VDC Two inputs: 12/24 VDC
Digital Inputs/Outputs
Two outputs:150 mA 48 VAC/ 150 mA 60 VDC Two outputs:150 mA 48 VAC/ 150 mA 60 VDC
Serial Port (1) RS-485, (1) RS-232 (1) RS-485, (1) RS-232
Opt isolated, 16-bit Opt isolated, 16-bit
Analog Output 0-20mA, 4-20mA (Maximum 350,000 ohm) 0-20mA, 4-20mA (Maximum 350,000 ohm)
(if equipped)
0-5VDC, 0-10VDC (Minimum 10,000 ohm) 0-5VDC, 0-10VDC (Minimum 10,000 ohm)
Six-digit 0.51 in (13 mm), red LED Six-digit 0.31 in (8 mm), red LED
Display
Annunciators: Net, center of zero, stability Annunciators: Net, center of zero, stability
Five key, membrane panel, tactile feel Five key, tactile feel
Keyboard
Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off) Zero (Down), Tare (Up), Mode (Right), Print (Enter), C (On/Off)
www.ricelake.com | Phone: 800-472-6703

Working Temperature: -15° C to 40° C Working Temperature: -10° C to 50° C


Temperature & Humidity
Humidity: 85% non-condensing Humidity: 85% non-condensing
4.17 in x 3.54 in x 2.28 in 0.98 in x 4.52 in x 4.72 in
Dimensions (W x H x D)
(106 mm x 90 mm x 58 mm) (25 mm x 115 mm x 120 mm)
Weight 1 lb (0.5 kg) 1 lb (0.5 kg)
Rating/Material NEMA Type 1 plastic pluggable connectors NEMA Type 1 plastic pluggable connectors
Warranty One-year limited warranty One-year limited warranty

Standard Features Standard Features


• Quick menu for real and theoretical calibration • HUB Mode connects up to 16 transmitters to one fieldbus
• Red LED display (13 mm) and six LEDs show active • Quick menu for real and theoretical calibration
functions • Red LED display with six-digits (8 mm) and six LEDs show
• Standard DIN rail-mounting with power supply active functions
and enclosures • Standard DIN rail mounting with power supply and enclosures
• Configurable calibration and setup parameters • Configurable calibration and setup parameters from keyboard
from keyboard
• Up to three calibration linearization points or three
• Up to three calibration linearization points or three from the keyboard
from the keyboard
• Reading of the net, gross and tare weights, clearing,
• Reading of the net, gross and tare weights, clearing, semi-automatic and presettable tare, scale switch, setting of
semi-automatic and presettable tare, scale switch, outputs application thresholds
setting of outputs application thresholds
• Diagnostic information via serial port, message display,
• Diagnostic information via serial port, message display, printing, setting of APW in counting mode, simulation of key
printing, setting of APW in counting mode, simulation of pressure, Modbus RTU
key pressure
• Double RS-485 port for a quick network connection
• Printer management on second serial port available
• Multi-range function allows for subdividing the scale capacity
in two, each up to 3,000 divisions

540

An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
SCT-3300
Signal Conditioning Transmitter/Indicator

INDICATORS / CONTROLLERS
SCT-3300 Specifications
Input: 20-28 VDC
Power Power consumption: 8 W
Excitation Voltage 10 VDC, 170 mA, 6 x 350 Ω
Analog Signal Input Range 3.5 to 24 mV
0.1 µV/graduation minimum
Analog Signal Sensitivity 1.0 µV/graduation recommended
A/D Sample Rate 300 Hz
Internal resolution: 16 million counts
Resolution System linearity: ± 0.01% full scale
Optoisolated, 16 bit
Analog Output 0-20 mA, 4-20 mA (max 300 ohm)
(if equipped) 0-10 VDC (min 10,000 ohm)
Working temperature: 14° F to 122° F (-10° C to 50° C)
Temperature & Humidity Humidity: 85% non-condensing
Dimensions (W x H x D) 4.56 in x 3.72 in x 2.4 in (114 mm x 93 mm x 60 mm)
Weight 0.5 lb (0.2 kg)
Rating/Material DIN rail mount: NEMA Type 1
Warranty One-year limited warranty

Standard Features

www.ricelake.com | Phone: 800-472-6703


• Powers up to six (350 Ω) load cells in parallel
(with a 24-bit A/D converter)
• A/D converter 24-bit (16,000,000 points)
• 12-bit analog output: 0-20 mA, 4-20 mA, 0-10 V
• Mounting on Omega/DIN rail for back panel or junction box
• IP67-rated enclosed versions

541

An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
SCT-30 and SCT-40
Signal Conditioning Transmitter/Indicator
INDICATORS / CONTROLLERS

APPROVALS APPROVALS
SCT converter
with analog output

SCT-30 Specifications SCT-40 Specifications


Input: 12 -24 VDC Input: 12 -24 VDC
Power Power consumption: 3W Power consumption: 5W
Excitation Voltage 5 VDC, 120 mA, 8 x 350 Ω 5 VDC, 240 mA, 16 x 350 Ω
Analog Signal Input Range ± 39 mV ±39 mV
0.1 µV/graduation minimum 0.1 µV/graduation minimum
Analog Signal Sensitivity 1.0 µV/graduation recommended 1.0 µV/graduation recommended
A/D Sample Rate 300 Hz 600 Hz
Internal resolution: 16 million counts
Internal resolution: 16 million counts
Resolution Weight display resolution: 999,999
System linearity: ± 0.01% full scale System linearity: ± 0.01% full scale
Digital Inputs/Outputs N/A 3 inputs 5-24 VDC, 5 outputs, 115 VAC/150 mA
Serial Port RS-485 RS-485 or RS-232 simplex supports up to 115,200 bps
Optoisolated, 16 bit Optoisolated, 16 bit
Analog Output 0-20 mA, 4-20 mA (max 300 ohm) 0-20 mA, 4-20 mA (max 300 ohm)
(if equipped) 0-10 VDC, 0-5 VDC (min 10,000 ohm) 0-10 VDC, 0-5 VDC (min 10,000 ohm)
Backlit graphic LCD, transmissive
Display Eight-digit alphanumeric tow line LCD, 5 mm high 128 x 64 pixel resolution, 60 x 32 mm visible area
Five-key tactile keypad
Keyboard Control knob and DIP switches Test, Zero, Tare, Print Menu, Escape, Left and Up, Navigator,
Enter
Working temperature: -4° F to 140° F (-20° C to 60° C) Working temperature: -4° F to 140° F (-20° C to 60° C)
Temperature & Humidity Humidity: 85% non-condensing Humidity: 85% non-condensing
www.ricelake.com | Phone: 800-472-6703

SCT converter (W x H x D): 3.54 in x 3.74 in x 2.36 in SCT converter (W x H x D): 5.82 in x 3.62 in x 2.36 in
(90 mm x 95 mm x 60 mm) (148 mm x 92 mm x 60 mm)
Dimensions (W x H x D) IP67 enclosure (W  x H x D): 6.69 in x 5.51 in x 3.74 in
(170 mm x 140 mm x 95 mm)
Weight 1 lb (0.5 kg) 1 lb (0.5 kg)
DIN rail mount: NEMA Type 1 DIN rail mount: NEMA Type 1
Rating/Material Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear Sealed enclosure: NEMA Type 4/IP67, plastic enclosure, clear
cover, six PG9 cord grips cover, six PG9 cord grips
Warranty One-year limited warranty One-year limited warranty

Standard Features Standard Features


• LCD display, 5 mm, eight-digit • LCD display, 60 mm x 32 mm
• Powers up to eight (350 Ω) load cells in parallel (with a • Supports up to eight independent reading channels
24-bit A/D converter) for load cells
• A/D converter 24-bit (16,000,000 points) 4.8 kHz • Displays weight, configuration, calibration
• 16-bit analog output: 0-20 mA, 4-20 mA, 0-5 V, 0-10 V, and error conditions
±5 V, and ±10 V • DIN rail mounting
• Mounting on Omega/DIN rail for back panel • Theoretical calibration, real-weight calibration
or junction box and error conditions
• IP67-rated enclosed versions • Push button or preset tare
• Diagnostic message for load cell disconnect and over • Converts digital weight to analog output or optional
capacity errors DeviceNet™, Profibus™ or EtherNet/IP™ protocols
• Supports ASCII or MODBUS RTU protocols
• Full scale analog cut put with zero setting and PLC
correction of analog signal
• Bit swapping selection for little endian and endian format
• Three digital inputs, five digital outputs
• One serial port, RS-232 simplex and RS-485 connection
542 • CD manual

An ISO 9001 Registered Company © 2019 Rice Lake Weighing Systems 01/19 Prices and specifications subject to change without notice. Visit ricelake.com for current prices.
SCT-1100, 2200, 3300, SCT-10, 20, 30 and SCT 40
Signal Conditioning Transmitter/Indicator

SCT-1100 SCT-10

INDICATORS / CONTROLLERS
Part Number/Price Part Number/Price
Est. Est.
Part # Description Price Part # Description Price
Weight Weight
129393
182588 Indicator, SCT1100-AN four load cell input with SCT-10 converter with analog output 1 lb Consult
1 lb Consult
analog output 129394 SCT-10 converter with analog output in enclosure 1 lb Consult
131129 Installation manual 1 lb Consult
SCT-2200
SCT-20
Part Number/Price
Part # Description Est. Price
Part Number/Price
Weight
Transmitters Est.
Part # Description Price
182587 * Indicator, SCT2200 for scale input to be used 1 lb Consult
Weight
with fieldbus module 129396 SCT-20 converter with analog output 1 lb Consult
182589 Indicator, SCT2200-AN Analog Output 1 lb Consult 129397 SCT-20 converter with DeviceNet ™
1 lb Consult
Fieldbus 129558 SCT-20 converter with Profibus DP ™
1 lb Consult
182592 Fieldbus, SCT2200,Profinet Module 1 lb Consult 129398 SCT-20 converter with EtherNet/IP ™
1 lb Consult
182594 Fieldbus, SCT2200, Wi-Fi Module 1 lb Consult 132534 SCT-20 converter with EtherNet TCP/IP ™
1 lb Consult
182593 Fieldbus, SCT2200, Profibus Module 1 lb Consult 156903 SCT-20 converter with Modbus/TCP 1 lb Consult
182591 Fieldbus, SCT2200, EtherNet/IP Module 1 lb Consult 131128 Installation manual 1 lb Consult
182596 Fieldbus, SCT2200, DeviceNet Module 1 lb Consult NTEP Approved
182598 Fieldbus, SCT2200, EtherCAT Module 1 lb Consult 162883 SCT-20 converter with analog output Consult
182597 Fieldbus, SCT2200, CANopen Module 1 lb Consult 162886 SCT-20 converter with EtherNet/IP Consult
188483 SCT converter RS 232/485 to EtherNet TCP/IP 162887 SCT-20 converter with EtherNet TCP/IP Consult
1 lb Consult
and Modbus TCP
182599 Cable 1 lb Consult SCT-30
*How to Order the SCT-2200
Order SCT-2200 transmitter.
Order fieldbus module (HUB mode connects up to 16 transmitters to one fieldbus module).
Part Number/Price
Order cables: (Number of SCTs — 1) + (1 for Fieldbus). Est.
Part # Description Price
Weight
SCT-3300 156794 SCT-30 converter with analog output 1 lb Consult
156834 SCT-30 converter with analog output in enclosure 1 lb Consult
Part Number/Price
131129 Installation manual 1 lb Consult

www.ricelake.com | Phone: 800-472-6703


Est.
Part # Description Price
Weight SCT-40
Transmitters
188725 Indicator, SCT-3300 four load cell input with 1 lb Consult
Part Number/Price
analog output
Est.
Part # Description Price
Power Supply Weight
170470 SCT-40 with analog output 1 lb Consult
Part Number/Price 170471 SCT-40 with DeviceNet 1 lb Consult
170472 SCT-40 with Profibus 1 lb Consult
Est.
Part # Description Price 170473 SCT-40 with EtherNet/IP 1 lb Consult
Weight
170474 SCT-40 with TCP/IP 1 lb Consult
88792 12 VDC 1.2 A DIN rail mounted power supply 1 lb Consult
170475 SCT-40 with Modbus/TCP 1 lb Consult
119244 24 VDC 1.3 A DIN rail mounted power supply 1 lb Consult
170476 SCT-40 with Profinet/I/O 1 lb Consult
131128 Installation manual 1 lb Consult

543