Air Conditioners and Heat Pump Products Full Line Catalog: New Product Line Up
Air Conditioners and Heat Pump Products Full Line Catalog: New Product Line Up
Global Brand
Our global brand serves over 100 counties in all climate zones around the world.
Europe
31 countries
CIS
10 countries
North America
Middle East 2 countries
10 countries
North Asia
3 countries Asia
15 countries
Africa
7 countries
Latin America
20 countries
Oceania
3 countries
Outdoor units are affected by extreme weather conditions which also affects the units performance.
In extreme cold climate and heavy snow fall conditions it is necessary to protect the outdoor unit from freezing.
Panasonic has developed special knowledge and technology for cold climate regions including Siberia and North America.
Panasonic can be characterized as a global pioneer in extreme cold climate heat pump design and installations.
1981
Launched low ambient heat pump units that
31 Big Air KE & KS Wall-Mounted Heat Pumps and AC
32 Slim Duct Heat Pumps (RAC)
provide heat in extreme cold climates.
33 4-Way Ceiling Cassette Heat Pumps (RAC)
34 Multi-Zone Outdoor Units & Combo Possibilities
2014
XE series –15°F heat operation
47 4-Way Ceiling Cassette Heat Pumps (PAC)
48 Ceiling Suspended Heat Pumps (PAC)
50 Residential Controllers (RAC)
51 Residential / Light Commercial Controllers (PAC)
52 Built-in Wi-Fi and Panasonic Control App
53 Wi-Fi Adapters and App
2020
ClimaPure XE series with nanoe™ X
54 Wireless Home - BACNet Integration
56 Controllers, Communications and Integrations
Indoor Air Purification
57 Accessories / Line Sets
58 Pipe Lengths, Fittings, Elevations and Refrigerant
59 Operation Range / Multi-Zone Wiring
60 Multi-Zone Tube Adapters
61 Model Identification
Exp
perience a fresher and moore
com
mforttab
ble indoor environment
*nanoeTM X reduces the concentration of select pollutants, mold, allergens, pollen, PM2.5, and odors and the
growth of certain viruses and bacteria, but does not prevent them.
How works?
Deodorizes Odors Helps maintain skin moisture
A B C
Stops moisture evaporation Corneum is maintained and smooth
Sebum
nanoe™ X reaches odor in fabric OH radicals break down Deodorizes smells in fabric
Stratum
odor-causing substances corneum
nanoe™ X reaches pollutants in fabrics OH radicals take hydrogen away OH radicals transform hydrogen to
from pollutants inhibit the activity of pollutants
2 0 2 0 F U L L L I N E CATA LO G 5
Panasonic’s Advanced
Air Purification System
Panasonic’s nanoe™ Technology is a revolutionary air purification system
that helps keep your living space fresh and clean for you and your family.
Various tyypes of o molds entter houses al a ong with h people and We have e ex
experime m ntntal
a resul u ts thahatt shhow nan
anoe™ ™ X is cap
apab
able
e
air.
r Evenen iff pr
prev
eventivev actioon is tak
ken inn ou
our everrydy ay livves
e , it
i is off inh
nhib
ibitin
ng alalleerg
rgen
ens,s, suc
uch h as pol olle
lenn an
andd du
dust
st mittes
e . It is
o ten ve
of v ry difffi
ficu
ult
l too inhi
h bi
b t th
he gr
grow
owth
th off mold, espe ecialllyy in important to o tak
ake pr
prec
ecauauti
tion
onss ag
agaiains
nstt th
the
e al
alle
lerg
rgen
enss th
that
at we
humi
hu midd en
envi
viro
ronm
nmenents. Wi
W thh nan
anoe
o ™ X, we ha have
ve exp
xper
erim
imenentatal inadve
in vert
rtenntl
tlyy in
inha
hale
le in ou
ourr da
dail
ilyy li
live
vess.
resu
re s lt
lts*11 th
that
at sho
howw we cana inhnhib
bit the gro
rowtwth
h off the typ
ypes
es As nanoe™ X is effective in inhibiting invisible allergens, we
of mol
oldd co
commmmon only
ly fou
ound
nd in
i varrious place
ces in the house. As can expect it will create a cleaner environment.**
nanoe™ X is also capable of inhibiting invisible bacteria and
viruses that exist in our living environment. I recommend that
equipment incorporating nanoe™ X technology be placed in
buildings where cleanliness is required, such as in schools,
childcare facilities and medical institutions.**
*1 Experimental results show that
at nanoe
nanoe™ X iss effective
tive in
n inhibiting the growth of the following types of mold commonly found in homes: Cladosporium, Aspergillus, Penicillium, Alternaria, Fusarium, Eurotium, Mucor, and Stachybotrys.
** The above indications and statements
ents ar
are mad
made
e in ref
reference
ce to available information.
Odorless
*nanoeTM X reduces the concentration of select pollutants, mold, allergens, pollen, PM2.5, and odors and the growth of certain viruses and bacteria, but does not prevent them.
1
<Cigarette smoke odor> [Test org.] Panasonic Product Analysis Center [Test method] Verified using the six-level odor intensity scale method in an approximately 23m3 sized test room [Deodorization method] nanoe™ released [Test substance] Surface-attached cigarette smoke odor [Test result] Odor intensity reduced by 2.4 levels in 12mins (4AA33-160615-N04)
2
<Pet odor>[Test org.] Panasonic Product Analysis Center [Test method] Verified using the six-level odor intensity scale method in an approximately 23m3 sized test room [Deodorization method] nanoe™ released [Test substance] Surface-attached pet odor [Test result] Odor intensity reduced by 1.5 levels in 1 hour (4AA33-160315-A34)
3
<Airborne bacteria (Staphylococcus aureus)> [Test org.] Kitasato Research Center for Environmental Science [Test method] The number of bacteria is measured after direct exposure in an approximately 25m3 sized airtight test room [Inhibition method] nanoe™ released [Test substance] Airborne bacteria [Test result] Inhibited by at least 99.7% in 4 hours (24_0301_1)
4
<Airborne virus (bacteriophage ƪLj174)> [Test org.] Kitasato Research Center for Environmental Science [Test method] The number of virus is measured after direct exposure in an approximately 25m3 sized airtight test room [Inhibition method] nanoe™ released [Test substance] Airborne virus [Test result] Inhibited by at least 99.7% in 6 hours (24_0300_1)
5
<Adhered bacteria (O157)> [Test org.] Japan Food Research Laboratories [Test method] Measured the number of bacteria adhered to a cloth in an approximately 45L sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered bacteria [Test result] Inhibited by at least 99.99% in 1 hour (208120880_001)
6
<Adhered virus (Influenza virus H1N1 subtype)> [Test org.] Kitasato Research Center for Environmental Science [Test method] Measured the number of virus adhered to a cloth in an approximately 1m3 sized airtight test room [Inhibition method] nanoe™ released [Test substance] Adhered virus [Test result] Inhibited by at least 99.9% in 2 hours (21_0084_1)
7
<Airborne mold (Cladosporium)> [Test org.] Japan Food Research Laboratories [Test Method] Measured the number of mold altered in an approximately 23m3 sized test room [inhibition method] nanoe™ released [Test substance] Airborne mold [Test result] inhibited by at least 99% in 1 hour (205061541-001)
8
<Adhered mold (Aspergillus)> [Test org.] Japan Food Research Laboratories [Test Method] Measured the mold adhered to a cloth [inhibition method] nanoe™ released [Test substance) Adhered mold [Test result) inhibited by at least 99.5% in 8 hours (11038081001-02)
7
Research into nanoe™ air improvement te
The nanoe™ technology has spr
Public transport
JR Kyushu JR East
Cruise trains: Keihan Main Line: Keio Line: Yamanote line:
Adopted for the Adopted for Adopted for Adopted for
Seven Stars admission-paid new railcar models E235 series models
in Kyushu special railcars
Morning
commute
Home
Home
Public spaces
Ceiling-embedded nanoe™ generators
Office
4-way cassette air conditioners
Elevators
Office
Automotive
Evening
commute
h nanoe™ Technology. Trade names, trademarks, and images of products/services are used in this material
under approval by the entities concerned in Japan (as of October 31st, 2019).
2 0 2 0 F U L L L I N E CATA LO G 9
Built-in Wi-Fi with Panasonic Control App:
Convenient centralized control
1
Smart Control Smart Efficiency
In control of cooling and heating comfort anytime,
anywhere.
3 More comfort with less wasted energy.
Energy usage analysis2
Connect & control operation Monitor energy consumption based on different
• 20 units per location and up to 10 different locations temperature settings.
• Transform multiple remote controls into one device Energy usage comparison (day/week/month/year)
Manage multiple units at once Compare energy usage history of AC units for better
• Turn on all AC units at the same time or by group budget planning.
settings
• Set weekly timers for multiple units to cater to your
Smart Assist
daily routines
4 Be informed of breakdowns.
Error codes notification and identification3
2
Smart Comfort
Launch the App to check error codes for effortless
Easily manage your comfort and air quality. troubleshooting. Help technicians to easily identify
Adjust set temperature the issues.
Set temperature by monitoring real time indoor and User’s control right
outdoor temperatures. Register multiple users. Set administrator rights and
Pre-heat or cool. assign users access.
Control your house or office comfort before you arrive!
nanoe™ X1 1) nanoe™ X is available in certain series.
2) Estimated energy consumption data accuracy depends on power supply quantity.
Activate nanoe™ X, the advanced technology to 3) Contact trained technicians to perform any repairing/service.
deodorize and create healthier environment.
Multi tenant owner: The ability to manage up to 200 units with just one
smartphone. It allows for quick and efficient maintenance through remote
error codes and the knowledge of consumption.
Small and medium sized offices: Owner can control different rooms of
the office easily and give unit by unit access to their staff. Also provides
information to know where energy might be wasted for heating and cooling
and promoting best comfort practices.
Search for “Panasonic Comfort”
in App Store
Network
Router Internet Smartphone Search for “Panasonic Comfort”
2 0 2 0 F U L L L I N E CATA LO G 11
New voice control.
Words do more than actions.
1 3
Turn on/off air conditioner Adjust temperature
Convenient control for blissful rest. Easy control for uninterrupted quality time.
Turn on/off AC with ease when preparing a Adjust AC temperature to your comfort with a simple
comfortable space for your little ones. voice command.
“Alexa, turn on the living room “Alexa, set the living room
air conditioner.” air conditioner to 72 °F.”
2
Change mode Check current status
Extra help when you have a hectic day.
Conveniently change your AC operation mode to
cool / heat / auto when your hands are full.
4 Hands-free comfort for the whole family.
Easy access for the elderly to check current AC
operation status and adjust AC settings.
Hey Google, set living room Hey Google, how cold is the
air conditioner to cool living room air conditioner?
“Alexa, set living room air “Alexa, how cold is the living
conditioner to cool.” room air conditioner?”
ON
2 0 2 0 F U L L L I N E CATA LO G 13
Rugged design that continues to operate
high performance even in cold climate of -15°F
PRECISE
Precise design
3
1
1
High-Efficiency Compressor Low Vibration
High-performance compressor with wide power output Anti-vibration rubber mounts
range operates accurately with less than 1 ampere for on the compressor legs absorb
precise operation. impact and improves durability.
2
Components arranged in an orderly manner are Inverter Technology
proof of high-precision and careful finishing. Advanced drive technology adjusts precise compressor motor rotation. During the start-up
The compressor, which is the heart of the air phase, the compressor quickly provides powerful, high-speed rotation; during the run phase
conditioner, is wrapped in insulation to provide the compressor smoothly shifts to a low speed rotation for energy savings. This maximizes
soundproofing and reduce condensation. compressor performance and optimizes high efficient operation.
4
Blue Fin Condenser
Blue Fin anti-rust coating is applied to each fin. This
special coating prevents rust from salt air and mois-
ture from rain and melting snow and assures longer
life of the heat exchanger.
3 layer structure
3 times longer lasting
Note: According to Panasonic test results.
3 5
High-Efficiency Blades Base Pan Heater/
Frost on heat exchanger is frequent in cold climates.
Multiple Drain Ports
The three blade, high static pressure design moves A heating element placed around the base pan
air quietly and evenly even under harsh conditions prevents freezing condensate inside the outdoor unit.
and provides high-efficiency operation. Multiple drain holes assist prompt drainage.
6
Quiet Silicone Coating Powder Coated Finish
Smooth rotation and low The brains of the air conditioner, An industrial grade paint used on exterior finishes
vibration ensure quiet printed circuit board is coated with for guardrails, automobile parts provide corrosion
operation and durability. silicone to prevent malfunction resistance and durability.
from insulation deterioration.
2 0 2 0 F U L L L I N E CATA LO G 15
Reliability and exceptional quality with over
200 quality assurance tests
A rugged design ensures that the air conditioners will
2 0 2 0 F U L L L I N E CATA LO G 17
With Panasonic, heating and cooling are
all-in-one providing year-round comfort
Winter Summer
All seasons outdoor condenser unit. The indoor and outdoor units are connected by refrigerant
pipes that cycle refrigerant gas between the indoor and outdoor units. The direction
of the gas can be switched which changes operation between heating and cooling.
YEAR-ROUND USE This switching change is done with a simple button push on the remote controller and
heating and cooling comfort is provided year-round.
Simply said, heat is transferred from outdoors to Simply said, heat is transferred from indoors to
At heating operation indoors using a compressor and high pressure, high At cooling operation outdoors using a compressor and high pressure,
temperature refrigerant. Cool air is drawn into the indoor unit and Warm air is high temperature refrigerant in a reverse cycle from heating. Warm moist air is drawn
released into the room. The refrigerant cycle continually repeats. into the indoor unit and Cool dry air is released into the room. The refrigerant cycle
continually repeats.
2 0 2 0 F U L L L I N E CATA LO G 19
Advanced Inverter & ECONAVI Technology
Optimum Performance
while reducing Energy Usage
Panasonic inverter technology constantly adjusts its compressor rotation
speed to provide maximum performance at all times. This precise operation
enables quick cooling or heating while reducing power consumption compared
to conventional non-inverter units.
Constant Comfort
Precise temperature control with a wide power output range enables an
inverter air conditioner to meet different room occupancy levels, providing • Wider Output Power Range
constant comfort.
Minimum Capacity
Quick Cooling and Heating 2,800Btu/h
Rated Capacity
Panasonic Inverter air conditioners can operate with higher cooling/heating
power during the start-up period to cool/heat the room faster than 8,700Btu/h
Maximum Capacity
non-inverter models.
12,000Btu/h
Whisper Quiet Operation
The indoor operating noise has been reduced by 5dB as the Inverter constantly
varies its output power to enable more precise temperature control.
What’s ECONAVI?
High-precision sensor technology allows efficient, automatic
operation to match room conditions. This keeps everyone
comfortable while saving energy.
2 0 2 0 F U L L L I N E CATA LO G 21
Air Conditioner and Heat Pump Line-Up
Your Best Choice in Mini Split Air Conditioning and Heat Pump Systems
Since 1983, Panasonic Mini Split Air Conditioner and Heat Pump products offer a wide range of versatile solutions for cooling
and heating requirements for single or multiple rooms. The indoor unit (evaporator) is mounted inside a room and connected
to the outdoor unit (condenser) via refrigerant lines and inter-unit wiring through a 3-1/2" opening in the wall. Since no
ductwork is required, installation is simple, fast and efficient. Ducted models are also available.
The indoor unit has been uniquely designed to provide whisper-quiet operation while delivering comfort throughout the room.
Panasonic Mini Split Systems are stylish and provide the quality and reliability you can count on.
Outdoor Unit
CU-2E18SBU-5 CU-3E19RBU-5 CU-4E24RBU-5 CU-5E36QBU-5
Wall Mount
CS-ME5RKUA CS-ME5RKUA CS-ME5RKUA CS-ME5RKUA
5,000 Btu/h
Wall Mount
CS-ME7RKUA CS-ME7RKUA CS-ME7RKUA CS-ME7RKUA
7,000 Btu/h
Wall Mount
CS-E9RKUAW CS-E9RKUAW CS-E9RKUAW CS-E9RKUAW
9,000 Btu/h
Wall Mount
CS-E12RKUAW CS-E12RKUAW CS-E12RKUAW CS-E12RKUAW
12,000 Btu/h
Wall Mount
N/A CS-E18RKUAW CS-E18RKUAW CS-E18RKUAW
18,000 Btu/h
Wall Mount
N/A N/A CS-E24RKUAW CS-E24RKUAW
24,000 Btu/h
4-Way Cassette
CS-ME9SB4U CS-ME9SB4U CS-ME9SB4U CS-ME9SB4U
9,000 Btu/h
Indoor Unit
4-Way Cassette
CS-E12RB4UW CS-E12RB4UW CS-E12RB4UW CS-E12RB4UW
12,000 Btu/h
4-Way Cassette
N/A CS-E18RB4UW CS-E18RB4UW CS-E18RB4UW
18,000 Btu/h
Slim Duct
CS-ME5SD3UA CS-ME5SD3UA CS-ME5SD3UA CS-ME5SD3UA
5,000 Btu/h
Slim Duct
CS-ME7SD3UA CS-ME7SD3UA CS-ME7SD3UA CS-ME7SD3UA
7,000 Btu/h
Slim Duct
CS-E9SD3UAW CS-E9SD3UAW CS-E9SD3UAW CS-E9SD3UAW
9,000 Btu/h
Slim Duct
CS-E12SD3UAW CS-E12SD3UAW CS-E12SD3UAW CS-E12SD3UAW
12,000 Btu/h
Slim Duct
N/A CS-E18SD3UAW CS-E18SD3UAW CS-E18SD3UAW
18,000 Btu/h
All Multi Zone Systems require a minimum 2 indoor units installed.
When selecting Multi-Zone please consider System Capacity and Indoor Unit Combinations. See pages 42 and 43.
Representative product images shown here. See product page for actual model images.
*See image of U-42PE1U6 double fan unit page 48.
2 0 2 0 F U L L L I N E CATA LO G 23
Model Feature Chart
LOW-AMBIENT
HEAT PUMPS COOLING ONLY
XE9WKUA
E9RKUA RE9SKUA
XE12WKUA YE9WKU1
E12RKUA RE12SKUA KE30NKU KS30NKUA
Wall Mounted XE15WKUA YE12WKU1 26PEK2U6
E18RKUA RE18SKUA KE36NKU KS36NKUA
XE18WKUA (115v)
E24RKUA RE24SKUA
XE24WKUA
26PET2U6
Ceiling 36PET2U6
42PET2U6
26PEU2U6
E12RB4U
4-Way Cassette E18RB4U
36PEU2U6
42PEU2U6
E9SD3UAW
26PEF2U6
Ducted E12SD3UAW
36PEF2U6
E18SD3UAW
Wi-Fi Built-in Option Option Option Option Option Option Option Option Option Option
Dry Mode D D D D D D D D D D D
Microprocessor-Controlled D D D D D D D D D D D
Operation
Wireless Remote Controller D D D D D D D Option Option Option D D
Wired Remote Controller Option Option Option Option Option Option D D D Option Option
Self-Diagnosing Function D D D D D D D
Louver Control D D D D D D D D D D
Low Ambient D D D D D D D D D D D D
R-410A Refrigerant D D D D D D D D D D D D
Quiet Mode D D D D D D D
Advanced nanoe™ X air purification technology with Units are equipped with Self-Diagnosing Function When this button is pushed either while the unit is
no maintenance required. (See pages 4-9) (methods are different depending on the models). operating or while it is stopped, the unit will operate
This makes it easier to diagnose malfunctions, greatly for one hour, then switch off automatically.
reducing service labor (Wired remote controller).
Wi-Fi Options
Filter Sign
Control heating and air conditioning through easy-to-
use smartphone app. Filter sign informs you when filter maintenance
• XE with Built-in Wi-Fi (See pages 10, 11, 52) (Example of CZ-RTC2) is necessary.
• Other models optional Wi-Fi adapter (See page 53) XE/E series with CZ-RDC516C-1
2 0 2 0 F U L L L I N E CATA LO G 25
The latest breakthrough in energy efficiency
and high performance
ClimaPure™
WALL MOUNTED HEAT PUMP
COLD CLIMATE SERIES
The new ClimaPure™ XE ductless heating and air conditioning system features nanoe™ X — a built-in air and surface
purification technology that provides a comfortable environment for occupants by reducing pollutants and odors. nanoe™ X
penetrates deep into the fibers of carpets and furniture to inhibit pollutants and odors. Featuring whisper-quiet heating
and cooling and advanced built-in air purification technology, the XE series sets a new standard for a comfortable indoor
environment.
BTU/h 3000 10900 18000 3000 12000 23000 3300 17200 24000 5800 20400 30000 5800 28800 33800
47⁰F
COP (W/W) 5.93 4.79 3.21 5.93 4.39 3.73 4.90 4.00 2.65 4.47 3.66 3.14 4.47 3.36 3.30
Heating BTU/h 8000 10000 11000 14000 18500
(Indoor Dry Bulb 70⁰F)
17⁰F
COP 3.13 2.79 3.16 2.93 2.64
BTU/h — 11000 — 12000 — 17200 — 20400 — 25200
5⁰F
COP — 2.30 — 2.20 — 2.10 — 2.30 — 2.170
V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Cooling Amp 2.6/2.9 3.8/4.2 5.4/6.0 6.2/6.9 10.1/11.1
Running Amps
Heating Amp 3.2/3.6 3.8/4.2 5.8/6.6 7.7/8.7 11.5/12.8
Cooling Watt 540 810 1170 1300 2200
Power Input
Heating Watt 670 800 1260 1630 2520
Base Pan Heater Watt 80 80 80 80 80
Min. Curcuit Ampacity Amp 15 15 20 20 25
Max. Overcurrent Protection Amp 15 20 25 25 30
Indoor H/W/D (ft) 11-5/8 34-9/32 9-1/16 11-5/8 34-9/32 9-1/16 11-5/8 34-9/32 9-1/16 11-29/32 43-13/32 9-5/8 11-29/32 43-13/32 9-5/8
Weight lb. 24 24 24 33 33
Unit
Outdoor H/W/D (ft) 24-1/2 32-15/32 11-25/32 24-1/2 32-15/32 11-25/32 27-3/8 34-15/32 12-5/8 31-5/16 34-15/32 12-5/8 31-5/16 34-15/32 12-5/8
Weight lb. 82 82 106 132 132
Indoor H/W/D (ft) 10-7/8 37-13/16 14-3/8 10-7/8 37-13/16 14-3/8 10-7/8 37-13/16 14-3/8 11-7/16 46-5/32 14-29/32 11-7/16 46-5/32 14-29/32
Weight lb. 26 26 26 37 37
Carton
Outdoor H/W/D (ft) 26-25/32 37-23/32 16-13/32 26-25/32 37-23/32 16-13/32 29-11/32 41-5/16 18-1/8 34-25/32 41-5/16 19-1/8 34-25/32 41-5/16 19-1/8
Weight lb. 88 88 53 66 66
2 0 2 0 F U L L L I N E CATA LO G 27
Deluxe Series Wall-Mount Heat Pump
E9RKUA / E12RKUA E18RKUA / E24RKUA
Pipe diameters listed below are for single zone only. Multi zone pipe diameters on page 58.
WALL MOUNT HEAT PUMPS
Model No. E9RKUA E12RKUA E18RKUA E24RKUA
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Unit Model No.
CS-E9RKUAW CU-E9RKUA CS-E12RKUAW CU-E12RKUA CS-E18RKUAW CU-E18RKUA CS-E24RKUAW CU-E24RKUA
Performance & Electrical Ratings
Cooling Btu/h 9,000 (4,100–10,200) 11,500 (4,100–13,300) 17,200 (5,800–19,800) 24,000 (5,800–27,200)
Capacity
Heating Btu/h 12,000 (4,100–14,100) 13,800 (4,100–16,300) 21,600 (5,800–22,000) 28,800 (5,800–29,200)
Moisture Removal High Pints/H 1.3 1.7 3.0 7.6
Dry Air Flow High CFM 425 450 670 670
SEER Cooling 23.0 22.5 19.5 19.0
EER Cooling 13.0 12.5 13.2 10.2
HSPF Heating 11.0 11.0 10.0 10.0
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Cooling A 3.2 / 3.6 4.2 / 4.7 6.3 / 7.0 10.8 / 11.9
Running Amps
Heating A 5.1 / 5.7 5.6 / 6.3 8.3 / 9.3 11.4 / 12.6
Cooling W 690 (250–850) 920 (250–1,150) 1,300 (430–1,600) 2,350 (430–2,720)
Power Input
Heating W 1,120 (200–1,500) 1,250 (200–1,710) 1,750 (380–1,800) 2,500 (380–2,660)
Min. Circuit Ampacity A 15 15 15 20
Max. Overcurrent Protection A 15 15 20 25
Features
Controls Microprocessor Microprocessor Microprocessor Microprocessor
Low Ambient Control Equipped Equipped Equipped Equipped
Wireless Controller Included Included Included Included
Wired Remote Controller(optional) CZ-RD516C-1 CZ-RD516C-1 CZ-RD516C-1 CZ-RD516C-1
Fan Speeds 5 Speeds + Auto 5 Speeds + Auto 5 Speeds + Auto 5 Speeds + Auto
Timer 24-hr Program 24-hr Program 24-hr Program 24-hr Program
Horizontal Manual Manual Automatic Automatic
Air Deflection
Vertical Automatic Automatic Automatic Automatic
Evaporator Guard Filter Included Included Included Included
Advanced Air Purification
PM2.5 (CZ-SA31P) Optional Optional Optional Optional
Features
Anti Microbial (CZ-SA20P) Optional Optional Optional Optional
Refrigerant R-410A R-410A R-410A R-410A
Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
In (Hi / Me / Lo) dB-A 42 / 29 / 26 44 / 35 / 32 47 / 39 / 36 48 / 40 / 37
Operation Sound
Outdoor (Hi) dB-A 48 49 49 51
Type Flare Flare Flare Flare
Refrigerant Piping
Discharge inches 1/4 1/4 1/4 1/4
(single zone)
Suction inches 3/8 1/2 1/2 5/8
Refrigerant Pipe Length Ft. Max. 65.6 Max. 65.6 Max. 100 Max. 100
Outdoor Above Ft. Max. 49.2 Max. 49.2 Max. 49.2 Max. 49.2
Elevation Difference*
Outdoor Below Ft. Max. 49.2 Max. 49.2 Max. 49.2 Max. 49.2
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 11-7/16 21-9/32 11-7/16 21-9/32 11-7/16 31-5/16 11-7/16 31-5/16
Width inches 34-9/32 30-23/32 34-9/32 30-23/32 42-5/32 34-15/32 42-5/32 34-15/32
Depth inches 8-7/16 11-13/32 8-7/16 11-13/32 9-15/32 12-5/8 9-15/32 12-5/8
Net Weight Lbs. 20.0 82.0 20.0 82.0 26.0 132.0 26.0 132.0
Important: You must use refrigerant piping rated for R410a.
*This is maximum elevation difference when the indoor unit is located above the outdoor unit. See p. 58 for additional information.
2 0 2 0 F U L L L I N E CATA LO G 29
115v Wall-Mounted Heat Pumps
YE9WKU1/YE12WKU1 YE Series
Wireless
INDOOR UNIT INDOOR UNIT
CS-YE9WKU1 / CS-YE12WKU1 CU-YE9WKU1 / CU-YE12WKU1
Controller
(Included)
-13°F Degrees and
Base Pan Heater
OUTDOOR UNIT Wireless Wired Remote Controller OUTDOOR UNIT Wireless Wired Remote Controller
Controller CZ-RD515U controller Controller CZ-RD515U controller
CU-KE30NKU/ (Included) CZ-RC515UA wire harness
CU-KS30NKUA/ (Included) CZ-RC515UA wire harness
CU-KE36NKU (Optional) CU-KS36NKUA (Optional)
2 0 2 0 F U L L L I N E CATA LO G 31
Slim Duct Heat Pumps
E9SD3UAW / E12SD3UAW / E18SD3UAW
• Low Profile Concealed Hidden in Ceiling or Floor • Energy Efficient DC Fan Motor
• Provides Heating in Winter and Cooling in Summer • Air Flow Adjustment Dip Switch on Indoor Circuit Board
• Energy Efficient Inverter Driven Compressor
Pipe diameters listed below are for single zone only. Multi zone pipe diameters on page 58.
SLIM DUCT
Indoor Single or Multi Single or Multi Single or Multi Single or Multi
Series E9SD3UA E12SD3UA E18SD3UA
Indoor Unit (order #) CS-E9SD3UAW CS-E12SD3UAW CS-E18SD3UAW
Outdoor Unit (order #) CU-E9SD3UA CU-E12SD3UA CU-E18SD3UA
Performance Ratings
Capacity Cooling Btu/h 9,000 (4,100–10,200) 11,500 (4,100–13,300) 17,200 (5,800–19,400)
Rated (Range) Heating Btu/h 12,000 (4100–14100) 13,800 (4100–16300) 20,800 (5,800–24,200)
Moisture Removal High Pints/H 1.30 1.70 4.60
Dry Air Flow High CFM 475 475 540
Static Pressure (Standard / Switch Hi) inch w.g. 0.10 / .022 0.10 / .022 0.10 / .023
SEER Cooling 20.5 20.0 16.5
EER Cooling 13.0 12.5 10.9
HSPF Heating Btu/h 10.0 10.0 8.5
Power Supply V, Phase, Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz
Cooling A 3.6 / 3.2 4.7 / 4.2 8.5 / 7.6
Running Amps
Heating A 5.7 / 5.1 6.3 / 5.6 9.8 / 8.7
Cooling W 690 (250–850) 920 (250–1150) 1.58k (430–1820)
Power Input
Heating W 1.12k (200–1500) 1.25k (200–1710) 1.83k (380–2180)
Auxiliary Heater Connection in. WC Yes Yes Yes
Min. Circuit Ampacity A 15 15 20
Max. Overcurrent Protection A 15 15 25
Features
Controls Microprocessor Microprocessor Microprocessor
Low Ambient Control Built-in Built-in Built-in
Wireless Controller Included Included Included
Wired Remote Controller (optional) CZ-RD52DU CZ-RD52DU CZ-RD52DU
Indoor Fan Speeds 5 speeds 5 speeds 5 speeds
Air Filter NA NA NA
Duct Flange NA NA NA
Refrigerant R-410A R-410A R-410A
Refrigerant Control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
Indoor (Hi/Med/Lo) dB-A 35 / 28 / 25 35 / 28 / 25 41 / 30 / 37
Operation Sound
Outdoor (Hi) dB-A 48 49 49
Type Flare Flare Flare
Refrigerant Piping Discharge inches 1/4 1/4 1/4
Suction inches 3/8 1/2 1/2
Refrigerant Pipe Length Ft. Max. 65.6 Max. 65.6 Max. 100
Outdoor Above Ft. 49.2 49.2 49.2
Elevation Difference
Outdoor Below Ft. 49.2 49.2 49.2
Dimensions & Weight
Height inches 7-7/8 7-7/8 7-7/8
Width inches 29-17/32 29-17/32 29-17/32
Indoor
Depth inches 25-7/32 25-7/32 25-7/32
Weight Lbs. 42.0 42.0 42.0
Height inches 21-11/32 21-11/32 31-5/16
Width inches 30-23/32 30-23/32 34-15/32
Outdoor
Depth inches 11-13/32 11-13/32 12-5/8"
Weight Lbs. 82.0 82.0 132.0
INDOOR UNIT
Wireless
CS-E12RB4UW* Controller
CS-E18RB4UW* (Included)
*Grille not included.
Sold separately.
GRILLE ASSEMBLY
Wired Controller
CZ-BT20U with 32 ft cable
(Order separately) CZ-RD52CU OUTDOOR UNIT OUTDOOR UNIT
(Optional)
CU-E12RB4U CU-E18RB4U
Pipe diameters listed below are for single zone only. Multi zone pipe diameters on page 45.
Horizontal — —
Air Deflection
Vertical Microprocessor Automatic
Air Filter Washable Washable
Refrigerant R-410A R-410A
Refrigerant Control Electric Expansion Valve Electric Expansion Valve
In (Hi / Me / Lo) dB-A 34 / 30 / 27 44 / 31 / 28
Operation Sound
Outdoor (Hi) dB-A 51 (Max. 66) 52 (Max. 66)
Type Flare Flare
Refrigerant Piping
Discharge inches 1/4 1/4
(single zone)
Suction inches 1/2 1/2
Refrigerant Pipe Length Ft. 65 100
Outdoor Above Ft. 49 49
Elevation Difference*
Outdoor Below Ft. 49 49
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 10-1/4 21-1/2 10-1/4 31-1/2
Width inches 22-3/4 31 22-3/4 34-1/2
Depth inches 22-3/4 11-1/2 22-3/4 12-3/4
Net Weight Lbs. 40 82 40 132
4-Way Airflow Design Sends Cool Air in All Directions Integrated Drain Pump
Air is returned through the center of the grille, while Drain pump is built into the unit to raise the
evenly distributing air through each of the 4 supply condensate water up to 20” from the drain
air openings. Installation in the center of the room pump discharge to a gravity drain.
provides for the greatest comfort. However, 1 or 2
supply louvers can be Comfort/Quiet Motor Drain
closed for installation water
Suction
2 0 2 0 F U L L L I N E CATA LO G 33
Multi-Zone Systems
2-3 Zone (1.5 Ton) Cooling Capacity: 19,000 (6,100 - 24,800) Btu/hr.
Heating Capacity: 26,000 (5,500 - 28,400) Btu/hr.
CU-3E19RBU-5 SEER Non-Ducted 22.0 / Ducted 18.5
EER Non-Ducted 12.55 / Ducted 10.85
HSPF Non-Ducted 10.5 / Ducted 9.0
(Non-Ducted) Min/Max capacity 15,300 - 30,600 Btu/hr.
All multi split condensors must have minimum two indoor units installed.
Combination Possibilities
MULTI ZONE CU-2E18SBU-5 CU-3E19RBU-5 CU-4E24RBU-5 CU-5E36QBU-5
CS-ME5RKUA D D D D
CS-ME7RKUA D D D D
CS-E9RKUAW D D D D
Wall
CS-E12RKUAW D D D D
CS-E18RKUAW – D D D
CS-E24RKUAW – – D D
CS-ME9SB4U D D D D
4-Way CS-E12RB4UW D D D D
CS-E18RB4UW – D D D
CS-ME5SD3UA D D D D
CS-ME7SD3UA D D D D
Ducted CS-E9SD3UAW D D D D
CS-E12SD3UAW D D D D
CS-E18SD3UAW – D D D
Capacity range of connectable indoor units 3.2 – 6.4 kW 4.5 – 9.0 kW 4.5 – 13.6 kW 4.5 – 17.5 kW
1 room maximum pipe length (m (ft)) 25 (82.0) 25 (82.0) 25 (82.0) 25 (82.0)
Allowable elevation (m (ft)) 15 (49.2) 15 (49.2) 15 (49.2) 15 (49.2)
Piping Length Total allowable pipe length (m (ft)) 50 (164.0) 50 (164.0) 70 (229.6) 80 (262.4)
Total pipe length for maximum chargeless length (m (ft)) 20 (65.6) 30 (98.4) 45 (147.6) 45 (147.6)
Additional gas amount over chargeless length (g/m (oz/ft)) 20 (0.2) 20 (0.2) 20 (0.2) 20 (0.2)
See Capacity and Combinations pages 42, 43
2 0 2 0 F U L L L I N E CATA LO G 35
Multi-Zone Systems
Indoor Units
Wall Mount
Wireless
Controller
(Included)
Wired Controller
with 32 ft cable
CZ-RD516C-1
(Optional)
4-Way Cassette
Wireless
Controller
(Included)
Wired Controller
with 32 ft cable
CZ-RD52CU
(Optional)
Slim Duct
Wireless Controller
with Receiver/Cable
(Included)
Wired Controller
with 32 ft cable
CZ-RD52DU
(Optional)
All Indoor multi zone units can be field modified to operate as Cooling Only.
4-WAY CASSETTE
Model No. CS-ME9SB4U CS-E12RB4UW CS-E18RB4UW
Performance & Electrical Ratings
Cooling Btu/h 8,600 (6,100 - 9,900) 10,900 (6,100–13,000) 171,000 (6,500–19,400)
Capacity
Heating Btu/h 12,300 ( 4,100 - 14,700) 15,300 (4,100–19,800) 23,400 (4,100–23,600)
Moisture Removal High Pints/H 2.5 3.2 4.4
Dry Air Flow High CFM 400 370(C),390(H) 450(C),495(H)
Power Supply V, Phase, Hz 208/230V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Cooling A 3.5 / 3.2 4.3 / 3.9 8.0 / 7.2
Running Amps
Heating A 5.2 / 4.7 6.6 / 6.0 10.7 / 9.7
Cooling W 630 (340 - 810) 800 (340~1,360) 1,550 (340~2.130)
Power Input
Heating W 300 (940 - 1.2k) 1,230 (300~2,100) 2,100 (300~2,520)
Operation Sound Cooling 36 / 30 / 27 36 / 30 36 / 32
[Hi / Me / Lo / Q-Lo ] Heating 37 / 32 / 29 36 / 32 46 / 33
Refrigerant Tube Discharge inches 1/4 1/4 1/4
Diameter Suction inches 3/8" 3/8 3/8
Adapters Required none CZ-MA1P-US CZ-MA1P-US
Dimensions & Weight
Height inches 10-1/4" 10-1/4 10-1/4
Width inches 22-3/4" 22-3/4 22-3/4
Indoor
Depth inches 22-3/4" 22-3/4 22-3/4
Net Weight lb 40.0 (grille 6.0) 40.0 40.0
Pipe diameters listed below are for Multi zone installations. For Single zone pipe diameter see single zone product pages.
SLIM DUCT
Model No. CS-ME5SD3UA CS-ME7SD3UA CS-E9SD3UAW CS-E12SD3UAW CS-E18SD3UAW
Performance & Electrical Ratings
Cooling Btu/h 5,500 (4,400 - 7,800) 6,900 (6,100 - 9,900) 9000 (4100-10200) 11500 (4100-13300) 17200 (5800-19400)
Capacity
Heating Btu/h 8,900 (4,100 - 10,900) 10,900 (4,100 - 14,000) 12000 (4100-14100) 13800 (4100-16300) 20800 (5800-24200)
Moisture Removal High Pints/H 0.8 1.1 1.30 1.70 4.60
Dry Air Flow High CFM 484 494 475 475 540
Static Pressure (Standard / Switch Hi) inch w.g. 0.10 / .022 0.10 / .022 0.10 / .022 0.10 / .022 0.10 / .023
Power Supply V, Phase, Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz 208/230V, 1PH, 60Hz
Cooling A 2.3 / 2.0 2.8 / 2.5 3.2 4.2 7.6
Running Amps
Heating A 3.4 / 3.0 4.1 / 3.7 5.1 5.6 8.7
Cooling W 400 (250 - 640) 500 (340 - 810) 690 (250 - 850) 920 (250 - 1.15k) 1.58k (430 - 1.82k)
Power Input
Heating W 600 (300 - 960) 740 (300 - 1.23k) 1.12k (200 - 1.50k) 1.25k (200 - 1.71k) 1.83k (380 - 2.18k)
Operation Sound Cooling 35 / 28 36 / 29 35 / 28 / 25 35 / 28 / 25 41 / 30 / 37
[Hi / Me / Lo / Q-Lo ] Heating 35 / 28 36 / 29 35 / 28 / 25 35 / 28 / 25 41 / 32 / 29
Refrigerant Tube Discharge inches 1/4" 1/4" 1/4 1/4 1/4
Diameter Suction inches 3/8" 3/8" 3/8 3/8 3/8
Adapters Required none none none CZ-MA1P-US CZ-MA1P-US
Dimensions & Weight
Height inches 7-7/8" 7-7/8" 7-7/8 7-7/8 7-7/8
Width inches 29-17/32" 29-17/32" 29-17/32 29-17/32 29-17/32
Indoor
Depth inches 25-7/32" 25-7/32" 25-7/32 25-7/32 25-7/32
Net Weight lb 42.0 42.0 42.0 42.0 42.0
Important: You must use refrigerant piping rated for R410a.
*This is maximum elevation difference when the indoor unit is located above the outdoor unit. See pages 57-60 for additional information.
2 0 2 0 F U L L L I N E CATA LO G 37
Multi-Zone Systems
2
CU-2E18SBU-5
Zone (1.5 Ton)
CU-2E18SBU-5 See Multi Zone Calculation and Selection Chart on pp. 42-43.
Outdoor Unit
MODEL NO. CU-2E18SBU-5
Performance Cooling Heating
Capacity Btu/h 16,700 (7,200~20,000) 20,200 (7,200~24,600)
Air Circulation High CFM 1,447
Number of Connectable Indoor Units 2
SEER Non-Ducted / Ducted 19.0 / 19.0
EER Non-Ducted / Ducted 12.55 / 12.55
HSPF Non-Ducted / Ducted 9.5 / 9.0
Electrical Rating
Power Supply V, Phase, Hz 230V / 208V, 1PH, 60Hz
Running Ampere Non-Ducted / Ducted A 6.6~6.0 / 6.6~6.0 8.5~7.8 / 8.5~7.8
Power Input W 1,330 1,750
Maximum Fuse Size : MCA / MOCP Amps 20 / 25
Features
Controls Microprocessor
Fan Speeds Variable Speed
Compressor DC Inverter
Refrigerant / Amount Charged at Shipment R-410A / 78.70 oz
Refrigerant Control Electronic Expansion Valve
Operation Sound Hi dB-A 48 49
Refrigerant Tubing Connections Type Flare
Max. Allowable Tubing Length Ft. 164 per system (82 per indoor unit)
Refrigerant Tube Diameter Discharge inch 1/4” x 2
(service value) Suction inch 3/8” x 2
Adapter Required Indoor 12K Btu/hr. requires 1 CZ-MA1P-US
Dimensions & Weight
Unit Dimensions HxWxD inch 31-5/16” x 34-15/32” (+3-3/4) x 14-3/6”
Net Weight Lbs. 157
Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
2-3
CU-3E19RBU-5
Zone (1.5 Ton)
CU-3E19RBU-5 See Multi Zone Calculation and Selection Chart on pp. 42-43.
(Non-Ducted)
Outdoor Unit
MODEL NO. CU-2E18SBU-5
Performance Cooling Heating
Capacity Btu/h 19,000 (6,100~24,800) 26,000 (5,500~28,400)
Air Circulation High CFM 1,447 1,634
Number of Connectable Indoor Units 2-3
SEER Non-Ducted / Ducted 22.0 / 18.5
EER Non-Ducted / Ducted 12.55 / 10.85
HSPF Non-Ducted / Ducted 10.5 / 9.0
Electrical Rating
Power Supply V, Phase, Hz 230V / 208V, 1PH, 60Hz
Running Ampere Non-Ducted / Ducted A 7.4~6.7 / 8.5~7.7 10.1~9.1 / 12.3~11.1
Power Input W 1,510 (360~2,420) 2,060 (320~2,300)
Maximum Fuse Size : MCA / MOCP Amps 20/30
Features
Controls Microprocessor
Fan Speeds Variable Speed
Compressor Twin Rotary, DC Motor, Inverter
Refrigerant / Amount Charged at Shipment R-410A / 93.2 oz
Refrigerant Control Electronic Expansion Valve
Operation Sound Hi dB-A 50 52
Refrigerant Tubing Connections Type Flare
Max. Allowable Tubing Length Ft. 164 per system (82 per indoor unit)
Refrigerant Tube Diameter Discharge inch 1/4” x 3
(service value) Suction inch 3/8” x 3
Adapter Required Indoor 12 and 18 Btu/hr. require 1 CZ-MA1P-US
Dimensions & Weight
Unit Dimensions HxWxD inch 31-5/16 x 34-15/32 x 14-3/6
Net Weight Lbs. 159
Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
2 0 2 0 F U L L L I N E CATA LO G 39
Multi-Zone Systems
CU-4E24RBU-5
Cooling Capacity: 24,000 (10,200 - 31,400) Btu/hr.
Heating Capacity: 37,800 (14,300 - 48,500) Btu/hr.
SEER Non-Ducted 22.0 / Ducted 19.0
EER Non-Ducted 12.55 / Ducted 10.85 Wireless Wired Remote
Controller Controller
HSPF Non-Ducted 9.5 / Ducted 9.0 (Included) CZ-RD516C-1
(Optional)
Min/Max capacity 15,300 - 30,600 Btu/hr.
CU-4E24RBU-5 See Multi Zone Calculation and Selection Chart on pp. 42-43.
(Non-Ducted)
Outdoor Unit
MODEL NO. CU-4E24RBU-5
Performance Cooling Heating
Capacity Btu/h 24,000 (10,200~31,400) 37,800 (14,300~48,500)
Air Circulation High CFM 1,963 2.330
Number of Connectable Indoor Units 2–4
SEER Non-Ducted / Ducted 22.0 / 19.0
EER Non-Ducted / Ducted 12.55 / 10.85
HSPF Non-Ducted / Ducted 9.5 / 9.0
Electrical Rating
Power Supply V, Phase, Hz 230V / 208V, 1PH, 60Hz
Running Ampere Non-Ducted / Ducted A 9.9~8.9 / 11.4~10.3 15.3~13.9 / 17.8~16.1
Power Input W 1,910 (530~2,870) 3,030 (700~4,380)
Maximum Fuse Size : MCA / MOCP Amps 30/45
Features
Controls Microprocessor
Fan Speeds Variable Speed
Compressor Twin Rotary, DC Motor, Inverter
Refrigerant / Amount Charged at Shipment R-410A / 120.0 oz
Refrigerant Control Electronic Expansion Valve
Operation Sound Hi dB-A 55 55
Refrigerant Tubing Connections Type Flare
Max. Allowable Tubing Length Ft. 230 per system (82 per indoor unit)
Refrigerant Tube Diameter Discharge inch 1/4” x 4
(service value) Suction inch 3/8” x 4
Adapter Required Indoor 12 and 18 Btu/hr. require 1 CZ-MA1P-US / 24 Btu/hr 1 CZ-MA1P-US and 1 CZ-MA3P-US”
Dimensions & Weight
Unit Dimensions HxWxD inch 39-11/32 x 37-1/32 x 13-13/32
Net Weight Lbs. 183
Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
CU-5E36QBU-5
Cooling Capacity: 36,000 (9,900 - 39,000) Btu/hr.
Heating Capacity: 37,800 (11,600 - 49,500) Btu/hr.
SEER Non-Ducted 18.5 / Ducted 16.5
EER Non-Ducted 9.6 / Ducted 8.3 Wireless Wired Remote
Controller Controller
HSPF Non-Ducted 10.0 / Ducted 9.5 (Included) CZ-RD516C-1
Min/Max capacity 15,300 - 59,500 Btu/hr. (Optional)
CU-5E36QBU-5 See Multi Zone Calculation and Selection Chart on pp. 42-43.
(Non-Ducted)
Outdoor Unit
MODEL NO. CU-5E36QBU-5
Performance Cooling Heating
Capacity Btu/h 36,000 (9,900–39,000) 37,800 (11,600~49,500)
Air Circulation High CFM 2,475
Number of Connectable Indoor Units 2-5
SEER Non-Ducted / Ducted 18.5 / 16.5
EER Non-Ducted / Ducted 9.6 / 8.3
HSPF Non-Ducted / Ducted 10.0 / 9.5
Electrical Rating
Power Supply V, Phase, Hz 230V / 208V, 1PH, 60Hz
Running Ampere Non-Ducted / Ducted A 19.0–17.2 / 21.1–19.1 14.8–13.4 / 17.5–15.8
Power Input W 3,750 (550–3,860) 2,900 (530–4,240)
Maximum Fuse Size : MCA / MOCP Amps 30/45
Features
Controls Microprocessor
Fan Speeds Variable Speed
Compressor Twin Rotary, DC Motor, Inverter
Refrigerant / Amount Charged at Shipment R-410A / 120.0 oz
Refrigerant Control Electronic Expansion Valve
Operation Sound Hi dB-A 55
Refrigerant Tubing Connections Type Flare
Max. Allowable Tubing Length Ft. 262 per system (82 per indoor unit)
Refrigerant Tube Diameter Discharge inch 1/4” x 5
(service value) Suction inch 3/8” x 5
Adapter Required CZ-MA2P 1 pc for 12K & 18K / CZ-MA2P
Indoor Adapter Indoor 12 and 18 Btu/hr. require 1 CZ-MA2P-US / 24 Btu/hr. 1 CZ-MA1P-US and 1 CZ MA3P-US
Dimensions & Weight
Unit Dimensions HxWxD inch 39-11/32 x 37-1/32 x 13-13/32
Net Weight Lbs. 183
Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
2 0 2 0 F U L L L I N E CATA LO G 41
Multi Zone Combination Charts
Understanding total System Capacity is an important step in sizing and selecting heat pump equipment.
Outdoor Unit Capacity: The System Capacity is the Cooling and Heating Capacity listed at the top of each Outdoor unit’s specification chart.
Indoor Unit Demand: The Cooling and Heating Capacities are listed at the top of the specification chart of each Indoor Unit (see page 37).
The total of these partial indoor capacities is the System Demand.
CU-2E18SBU-5 CU-3E19RBU-5
2 Zones 2 Zones 3 Zones
5+5 5 + 12 5+5+5 7+7+7
5+7 5 + 18 5+5+7 7+7+9
5+9 5 + 18 5+5+7 7+7+9
5 + 12 7 + 12 5 + 5 + 12 7 + 7 + 18
7+7 7 + 18 5 + 5 + 18 7+9+9
7+9 9+9 5+7+7 7 + 9 + 12
7 + 12 9 + 12 5+7+9 7 + 12 + 12
9+9 9 + 18 5 + 7 + 12 9+9+9
9 + 12 12 + 12 5 + 7 + 18 9 + 9 + 12
12 + 12 12 + 18 5+9+9 9 + 12 + 12
— 5 + 9 + 12 —
— 5 + 12 + 12 —
CU-4E24RBU-5
2 Zones 3 Zones 4 Zones
5 + 18 5+5+5 7 + 7 + 12 5+5+5+5 5 + 7 + 7 + 24 7 + 7 + 9 + 24
5 + 24 5+5+7 7 + 7 + 18 5+5+5+7 5+7+9+9 7 + 7 + 12 + 12
7+9 5+5+9 7 + 7 + 24 5+5+5+9 5 + 7 + 9 + 12 7 + 7 + 12 + 18
7 + 12 5 + 5 + 12 7+9+9 5 + 5 + 5 + 12 5 + 7 + 9 + 18 7+9+9+9
7 + 18 5 + 5 + 18 7 + 9 + 12 5 + 5 + 5 + 18 5 + 7 + 9 + 24 7 + 9 + 9 + 12
7 + 24 5 + 5 + 24 7 + 9 + 18 5 + 5 + 5 + 24 5 + 7 + 12 + 12 7 + 9 + 9 + 18
9+9 5+7+7 7 + 9 + 24 5+5+7+7 5 + 7 + 12 + 18 7 + 9 + 12 + 12
9 + 12 5+7+9 7 + 12 + 12 5+5+7+9 5 + 7 + 18 + 18 7 + 9 + 12 + 18
9 + 18 5 + 7 + 12 7 + 12 + 18 5 + 5 + 7 + 12 5+9+9+9 7 + 12 + 12 + 12
9 + 24 5 + 7 + 18 7 + 12 + 24 5 + 5 + 7 + 18 5 + 9 + 9 + 12 7 + 12 + 12 + 18
12 + 12 5 + 7 + 24 7 + 18 + 18 5 + 5 + 7 + 24 5 + 9 + 9 + 18 9+9+9+9
12 + 18 5+9+9 9+9+9 5+5+9+9 5 + 9 + 9 + 24 9 + 9 + 9 + 12
12 + 24 5 + 9 + 12 9 + 9 + 12 5 + 5 + 9 + 12 5 + 9 + 12 + 12 9 + 9 + 9 + 18
18 + 18 5 + 9 + 18 9 + 9 + 18 5 + 5 + 9 + 18 5 + 9 + 12 + 18 9 + 9 + 12 + 12
18 + 24 5 + 9 + 24 9 + 9 + 24 5 + 5 + 9 + 24 5 + 12 + 12 + 12 9 + 9 + 12 + 18
— 5 + 12 + 12 9 + 12 + 12 5 + 5 + 12 + 12 5 + 12 + 12 + 18 9 + 12 + 12 + 12
— 5 + 12 + 18 9 + 12 + 18 5 + 5 + 12 + 18 7+7+7+7 12 + 12 + 12 + 12
— 5 + 12 + 24 9 + 12 + 24 5 + 5 + 12 + 24 7+7+7+9 —
— 5 + 18 + 18 9 + 18 + 18 5 + 5 + 18 + 18 7 + 7 + 7 + 12 —
— 5 + 18 + 24 12 + 12 + 12 5+7+7+7 7 + 7 + 7 + 18 —
— 7+7+7 12 + 12 + 18 5+7+7+9 7 + 7 + 7 + 24 —
— 7+7+9 12 + 12 + 24 5 + 7 + 7 + 12 7+7+9+9 —
— — 12 + 18 + 18 5 + 7 + 7 + 18 7 + 7 + 9 + 12 —
CU-5E36QBU-5
2 Zones 3 Zones 4 Zones 5 Zones
5 + 12 5+5+5 7+7+7 5+5+5+5 5 + 7 + 18 + 18 7 + 9 + 9 + 18 5+5+5+5+7 5+5+9+9+9 5 + 7 + 12 + 12 + 12 7 + 7 + 9 + 9 + 18
5 + 18 5+5+7 7+7+9 5+5+5+7 5 + 7 + 18 + 24 7 + 9 + 9 + 24 5+5+5+5+9 5 + 5 + 9 + 9 + 12 5 + 7 + 12 + 12 + 18 7 + 7 + 9 + 9 + 24
5 + 24 5+5+9 7 + 7 + 12 5+5+5+9 5+9+9+9 7 + 9 + 12 + 12 5 + 5 + 5 + 5 + 12 5 + 5 + 9 + 9 + 18 5 + 7 + 12 + 12 + 24 7 + 7 + 9 + 12 + 12
7+9 5 + 5 + 12 7 + 7 + 18 5 + 5 + 5 + 12 5 + 9 + 9 + 12 7 + 9 + 12 + 18 5 + 5 + 5 + 5 + 18 5 + 5 + 9 + 9 + 24 5 + 7 + 12 + 18 + 18 7 + 7 + 9 + 12 + 18
7 + 12 5 + 5 + 18 7 + 7 + 24 5 + 5 + 5 + 18 5 + 9 + 9 + 18 7 + 9 + 12 + 24 5 + 5 + 5 + 5 + 24 5 + 5 + 9 + 12 + 12 5+9+9+9+9 7 + 7 + 9 + 12 + 24
7 + 18 5 + 5 + 24 7+9+9 5 + 5 + 5 + 24 5 + 9 + 9 + 24 7 + 9 + 18 + 18 5+5+5+7+7 5 + 5 + 9 + 12 + 18 5 + 9 + 9 + 9 + 12 7 + 7 + 9 + 18 + 18
7 + 24 5+7+7 7 + 9 + 12 5+5+7+7 5 + 9 + 12 + 12 7 + 9 + 18 + 24 5+5+5+7+9 5 + 5 + 9 + 12 + 24 5 + 9 + 9 + 9 + 18 7 + 7 + 12 + 12 + 12
9+9 5+7+9 7 + 9 + 18 5+5+7+9 5 + 9 + 12 + 18 7 + 12 + 12 + 12 5 + 5 + 5 + 7 + 12 5 + 5 + 9 + 18 + 18 5 + 9 + 9 + 9 + 24 8 + 7 + 12 + 12 + 18
9 + 12 5 + 7 + 12 7 + 9 + 24 5 + 5 + 7 + 12 5 + 9 + 12 + 24 7 + 12 + 12 + 18 5 + 5 + 5 + 7 + 18 5 + 5 + 12 + 12 + 12 5 + 9 + 9 + 12 + 12 9 + 7 + 12 + 12 + 24
9 + 18 5 + 7 + 18 7 + 12 + 12 5 + 5 + 7 + 18 5 + 9 + 18 + 18 7 + 12 + 12 + 24 5 + 5 + 5 + 7 + 24 5 + 5 + 12 + 12 + 18 5 + 9 + 9 + 12 + 18 7 + 7 + 12 + 18 + 18
9 + 24 5 + 7 + 24 7 + 12 + 18 5 + 5 + 7 + 24 5 + 9 + 18 + 24 7 + 12 + 18 + 18 5+5+5+9+9 5 + 5 + 12 + 12 + 24 5 + 9 + 9 + 12 + 24 7+9+9+9+9
12 + 12 5+9+9 7 + 12 + 24 5+5+9+9 5 + 12 + 12 + 12 7 + 12 + 18 + 24 5 + 5 + 5 + 9 + 12 5 + 5 + 12 + 18 + 18 5 + 9 + 9 + 18 + 18 8 + 9 + 9 + 9 + 12
2 0 2 0 F U L L L I N E CATA LO G 43
Residential and Commercial Units (PACi)
26PEK2U6
Wireless CZ-CENSC1*
INDOOR UNIT Controller Econavi Sensor
OUTDOOR UNIT
(Optional)
S-26PK2U6 (Option) U-26PE1U6
(Included)
2 0 2 0 F U L L L I N E CATA LO G 45
Concealed Duct-Medium Static Heat Pumps
26PEF2U6 36PEF2U6
INDOOR UNIT INDOOR UNIT
S-26PF2U6 (Optional) S-36PF2U6 (Optional)
Supplies are 8” dia
CONCEALED DUCT
Heat Pumps
Model No. 26PEF2U6 36PEF2U6
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Unit Model No.
S-26PF2U6 U-26PE1U6 S-36PF2U6 U-36PE1U6
Performance & Electrical Ratings
Cooling Btu/h 24,000 (9,500–24,000) 31,200 (9,500–31,200)
Capacity
Heating Btu/h 28,600 (8,000–28,600) 36,200 (8,000–36,200)
Moisture Removal High Pints/H 4.6 2.9
Dry Air Flow Hi / Med / Low CFM 670 / 530 / 460 1,060 / 920 / 750
SEER Cooling 16.2 15.5
EER Cooling 8.8 8.6
HSPF Heating 9.9 9.0
Power Supply V, Phase, Hz 230/208, 1Ph, 60Hz 230/208, 1Ph, 60Hz
Cooling A 13.6 / 15.0 18.6 / 20.6
Running Amps
Heating A 12.5 / 13.8 15.9 / 17.6
Cooling W 2,600 / 2,600 3,920 / 3,920
Power Input
Heating W 2,400 / 2,400 3,340 / 3,340
External Static Pressure in. WC 0.20 0.24
Min. Circuit Ampacity A 15 17 15 21
Max. Overcurrent Protection A 15 30 15 35
Features
Controls Microprocessor Microprocessor
Low Ambient Control Built-in 0˚F Built-in 0˚F
Wireless Remote Controller (optional) CZ-RWSU3U, CZ-RWSC1U CZ-RWSU3U, CZ-RWSC1U
Wired Remote Controller (optional) CZ-RTC4 / CZ-RTC5 CZ-RTC4 / CZ-RTC5
Fan Speeds 3 and Automatic Control / Variable 3 and Automatic Control / Variable
Timer 7 Days / 6 Events 7 Days / 6 Events
Horizontal — —
Air Deflection
Vertical — —
Air Filter — —
Refrigerant Control Electric Expansion Valve Electric Expansion Valve
In (Hi / Me / Lo) dB-A 34 / 30 / 27 38 / 33 / 31
Operation Sound
Outdoor (Hi) dB-A 49 52
Type Flare Flare
Refrigerant Piping Discharge inches 3/8 3/8
Suction inches 5/8 5/8
Refrigerant Pipe Length Ft. Max. 165 Max. 165
Outdoor Above Ft. Max. 100 Max. 100
Elevation Difference**
Outdoor Below Ft. Max. 50 Max. 50
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 11 7/16 30-23/32 12-7/32 30-23/32
Width inches 39-3/8 37 58-9/32 37
Depth inches 27 9/16 13-3/8 24-13/16 13-3/8
Net Weight Lbs. 73.0 128.0 104.0 143.0
**This is maximum elevation difference when the indoor unit is located above the outdoor unit. See p. 58 for additional information.
CZ-RWSU3U
INDOOR UNIT Wireless Controller (Optional)
Transmitter/Receiver Kit
S-26PU2U6*
S-36PU2U6*
S-42PU2U6*
CZ-CENSC1*
*Grille not included. Econavi Sensor
Sold separately. (Optional)
CZ-RTC4*
Standard Wired
Remote Controller
Installation Example
Thanks to the newly developed turbo fan and decreased
resistance of the air path, one of the industry’s lowest
levels of noise has been achieved.
2 0 2 0 F U L L L I N E CATA LO G 47
Ceiling Suspended Heat Pumps
INDOOR UNIT
S-26PT2U6 (Optional)
S-36PT2U6
S-42PT2U6
CZ-RWST2U*
Wireless Controller
with Receiver
(Optional)
CZ-CENSC1*
Econavi Sensor
(Optional)
CZ-RTC4*
Standard Wired
Remote Controller
(Optional)
CZ-RTC5A*
High-spec Wired
Remote Controller
(Optional)
Application Example
The ceiling-mounted unit is equipped
with a highly efficient, multi-blade
centrifugal fan that generates a
powerful, yet gentle airflow throughout
the room.
A redesigned aerodynamically tested
louver structure minimizes operational
sound even at high fan speed
CEILING
Heat Pumps
Model No. 26PET2U6 36PET2U6 42PET2U6
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Unit Model No.
S-26PT2U6 U-26PE1U6 S-36PT2U6 U-36PE1U6 S-42PT2U6 U-42PE1U6
Performance & Electrical Ratings
Cooling Btu/h 24,000 (9,500–24,000) 32,600 (9,500–32,600) 39,000 (14,000–39,000)
Capacity
Heating Btu/h 27,000 (8,000–27,000) 36,200 (8,000–36,200) 44,500 (13,500–44,500)
Moisture Removal High Pints/H 5.3 6.5 8.4
Dry Air Flow Hi / Med / Low CFM 742 / 636 / 547 1,059 / 883 / 812 1,201/ 989 / 848
SEER Cooling 16.8 18.0 16.7
EER Cooling 8.9 9.2 9.4
HSPF Heating 9.4 9.5 10.2
Power Supply V, Phase, Hz 230 / 208 / 1 / 60 230 / 208 / 1 / 60 230 / 208 / 1 / 60
Cooling A 14.4 / 15.9 16.6 / 18.3 21.2 / 23.4
Running Amps
Heating A 12.9 / 14.3 13.9 / 15.4 19.6 / 21.7
Cooling W 2,700 / 2,700 3,550 / 3,550 4,160 / 4,160
Power Input
Heating W 2,430 / 2,430 3,000 / 3,000 3,860 / 3,860
Min. Circuit Ampacity A 15 17 15 21 15 24
Max. Overcurrent Protection A 15 30 15 35 15 40
Features
Controls Microprocessor Microprocessor Microprocessor
Low Ambient Control (for Cooling) Built-in 0˚F Built-in 0˚F Built-in 0˚F
Wireless Remote Controller (optional) CZ-RWST2U CZ-RWST2U CZ-RWST2U
Wired Remote Controller (optional) CZ-RTC4 / CZ-RTC5 CZ-RTC4 / CZ-RTC5 CZ-RTC4 / CZ-RTC5
Fan Speeds 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable
Timer 7 Days / 6 Events 7 Days / 6 Events 7 Days / 6 Events
Horizontal — — —
Air Deflection
Vertical Automatic Automatic Automatic
Air Filter Washable Washable Washable
Refrigerant R-410A R-410A R-410A
Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
In (Hi / Me / Lo) dB-A 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36
Operation Sound
Outdoor (Hi) dB-A 49 52 53
Type Flare Flare Flare
Refrigerant Piping Discharge inches 3/8 3/8 3/8
Suction inches 5/8 5/8 5/8
Refrigerant Pipe Length Ft. Max. 165 Max. 165 Max. 165
Outdoor Above Ft. Max. 100 Max. 100 Max. 100
Elevation Difference*
Outdoor Below Ft. Max. 50 Max. 50 Max. 50
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 9-1/4 30-23/32 9-1/4 30-23/32 9-1/4 48-7/16
Width inches 50-13/64 37 62-19/32 37 62-19/32 37
Depth inches 27-11/64 13-3/8 27-11/64 13-3/8 27-11/64 13-3/8
Net Weight Lbs. 73.0 128.0 88.0 143.0 88.0 220.0
*This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalog)
2 0 2 0 F U L L L I N E CATA LO G 49
Remote Controllers – Residential (RAC)
CS-ME5RKUA
CS-ME7RKUA
CS-E9RKUAW
CS-E12RKUAW
Exterios E CS-E18RKUAW CZ-RD516C-1
CS-E24RKUAW (Included)
(Optional)
CS-RE9SKUA
CS-RE12SKUA
CS-RE18SKUA
CS-RE24SKUA
Pro Series (Included)
CS-YE9WKU1
N/A
CS-YE12WKU1
PPro SSeries
i (115
(115v)) (Included)
CS-KE30NKU
CS-KE36NKU
CS-KS30NKUA *CO
Big Air CS-KS36NKUA *CO CZ-RD515U
(Included) (CZ-RC515UA harness Option)
CS-ME5SD3UA
CS-ME7SD3UA
CS-E9SD3UAW
CS-E12SD3UAW CZ-RD52DU
Slim Duct CS-E18SD3UAW (Included) (Option)
CS-ME9SB4U
CS-E12RB4UW
CS-E18RB4UW
CZ-RD52CU
4-Way Cassette (Included) (Option)
S26PK2U6
OPTION A:
(Included) *CZ-RTC5A High Spec Control
With filter countdown
For Title 24, ECONAVI Ready
S26PT2U6
S36PT2U6
S42PT2U6
CZ-RWST2U OPTION B:
Controller with Receiver (Option) CZ-RTC4 Timer Control
ECOVAVI Ready
S26PF2U6
S36PF2U6
CZ-RWSK1U Controller CZ-CENSC1
CZ-RWSC3 Receiver (Option) ECONAVI Sensor (Option)
S26PU2U6
S36PU2U6
S42PU2U6 Option C:
CZ-RWSU3U CZ-RE2C2 with on/off,
Controller with Receiver (Option) temp and mode control
*High-Spec Wired Remote Controller, Stylish, Easy to Use and ECONAVI Ready
2 0 2 0 F U L L L I N E CATA LO G 51
Panasonic Built-in Wi-Fi and App
Network
Adapter Panasonic Control App (free)
Router Internet Smartphone Search for “Panasonic
Comfort”
• Requires the APP to work with a smartphone with Android 4.4 and above, or iOS 9 and above.
However, it can’t be guaranteed that the APP will work well with all Android OS version.
• The Network Adapter is designed specifically as a terminal for Panasonic Control app.
• The Wireless LAN network coverage must reach the air conditioner installation location.
Specification
Network Adapter Wireless LAN Module (built-in)
Model DNSK-P11
Input Voltage DC 5V (From Air Conditioner Indoor Unit)
Current Consumption Tx/Rx max. 290/100 mA
Wireless LAN standard IEEE 802.11 b/g/n
Frequency range 2.4 GHz band
Encryption WPA2-PSK (TKIP/AES)
App Instructions
For Android user (Android 4.4 and above) For iOS user (iOS 9 and above)
• Open • Open
• Search for “Panasonic Comfort.” • Search for Panasonic Control app.
• Download and install. • Download and install.
Internet Connect devices remotely control a system with one or more indoor units via the cloud. An Internet Control
adapter is required for every indoor unit. Requires an internet connection and a Wi-Fi router, Control your equipment
using any web browser, iOS or Android device.
All Internet Control features are included for free up to 50 indoor units. The Pro License is required to control 51 or more indoor units.
• On/Off • AC Unit Error Signals, Codes and Descriptions • Multiple Home/Zone Management
• Heat, Cool, Dry and Auto Modes • Multi-lingual Interface • Powerful and Energy Savings Models
• Set Point Temperature • Automatic Firmware Updates • Advanced User Functions
• Adjust Fan Speed • Allows Multiple Users • AC Unit Error Signals, Codes and Descriptions
• Louver Direction (if applicable) • Annual Schedule Up to 10 Timers and Scenes • Error E-mail Notifications
• Ambient Temperature • Multiple Home/Zone Management • User Defined Alerts
Simple Installation
Just connect the Internet Control device to the air conditioner or heat pump with the supplied wire and then link it to your Wi-Fi access point.
* Use optional external Wi-Fi Adapter and App for Internet connection with all models. See Interface Controls list.
2 0 2 0 F U L L L I N E CATA LO G 53
BACnet Integration
BACnet IP and MSTP Controller. Requires (1) device per indoor unit.
The USPA-AC-BAC-1, USPA-RC2-BAC-1 and USPA-AC-BAC-128 all feature occupied/unoccupied heat and cool set points for
reduced programming time and greater energy efficiency.
Global and Individual Operation/Setting Objects Global and Individual Monitor/Status Objects
• All On/Off • On/Off
• On/Off • Mode
• Mode • Setpoint
• Setpoint • Fan Speed
• Fan Speed • Air Direction (n/a for ducted units)
• Air Direction (n/a for ducted units) • Space Temperature
• Prohibit Thermostat Functions
• Filter Sign Reset
• Filter Sign Reset
• Prohibit Thermostat Functions
• Unit and System Error Codes
• Occupied/Unoccupied All
• CZ-CFUNC1U Error Codes (BAC-128)
• Occupied/Unoccupied Cool Setpoints
• Occupied/Unoccupied Mode
• Occupied/Unoccupied Heat Setpoints • Today, Yesterday and Total Run Time Consumption
• Run Time Consumption Reset
• ECONAVI-Human detection (if available)
The CZ-CLNC1U offers the following setting and monitoring objects. Some Objects are not available on all indoor models.
Features: The following operations from the central control device can be performed
• Operations to start/stop the room AC, switch to operation mode, and set the temperature, fan speed and fan
direction (up/down).
• Monitor the operation status and abnormality of room air conditioner.
• Prohibiting the remote control operation of room air conditioner
• Using On/Off contact of external connection can start/stop the room air conditioner, prohibit/permit the remote
control operation, and perform emergency stop. A coin timer or card key can also be contacted.
• Retrieving the operation signal of abnormal signal of room air conditioner. (An external power source (DC12V) is
separately required.)
2 0 2 0 F U L L L I N E CATA LO G 55
Controllers, Communication and Integration
MODEL NO. DESCRIPTION USE WITH
RAC Wired Controllers
CZ-RD52CU Wired Remote Controller (4-Way Ceiling Recessed) 4-Way Ceiling Reccessed: E**RB4U
CZ-RD52DU Wired Remote Controller (4-Way Ceiling Recessed) Slim Duct: E**SD3UA
CZ-RC515UA Wire Harness (required with CZ-RD515U) PCB Wire Kit for CZ-RD515U. Required for use with KE, KS 30 & 36 Models
CZ-RWSK1U Wireless Controller Concealed Duct: S-26/36PF1U6, S-26/36/42PF2U6 (Included with Wall S-26PK2U6)
CZ-RWSC3 Receiver (Controller & Receiver ordered separately) Concealed Duct: S-26/36PF1U6, S-26/36/42PF2U6
CZ-RWSU3U Wireless Controller 4-Way Ceiling Recessed: S-26/36/42PU2U6 (for *2U6 models)
CZ- RWST2U Wireless Controller Ceiling Suspended: S-26/36/42PT2U6 (for *2U6 models)
Interface Controls
USPA-AC-WIFI-1B Wi-Fi Interface for RAC (XE models, E9/E12NKUAW) XE models, E9/12NKUAW, S9/12NKUA, ME7QKUA, ME7RKUA, E**RKUAW, E12/18RB4UW
USPA-RC2-WIFI-1 Wi-Fi Interface for PAC & ECOi All 26,000 ~ 42,000 BTU/h Models, except KS30/36NKU and KE 30/36NKU
USPA-AC-BAC-1 BACnet Interface for RAC (XE / E**NKUA Series) All XE, E9/12NKUA, S9/12NKUA, ME7QKUA, ME7RKUA, E**RKUAW, E12/18RB4UW
USPA-RC2-BAC-1 BACnet Interface for PAC & ECOi All 26,000 ~ 42,000 BTU/h Models, except KS30/36NKU and KE30/36NKU
YE9WKU1, YE12WKU1
WINDB-1A Wind Baffle - Side Discharge Fan
22.5 " wide - Single Fan - 1 Baffle, Double Fan - 2 Baffles
XE15WKUA, XE18WKUA, XE24WKUA,
WINDB-M1 Wind Baffle - Small Multi/Large Single Coil Side CU-2E18SBU, CU-3E19RBU, CU-E12RBU, CU-E18RBU, CU-E18RKUA,
CU-E24RKUA, CU-RE18SKUA, CU-RE24SKUA, CU-E18SD3UA
XE9WKUA, XE12WKUA,
WINDB-R1 Wind Baffle - Small Single Coil Side CU-E12RBU, CU-E18RBU, CU-E9RKUA, CU-E12RKUA, CU-RE9SKUA,
CU-RE12SKUA, CU-E9SD3UA, CU-E12SD3UA
WINDB-P1 Wind Baffle - Small PACi Single Coil Side U-26PE1U6, U-36PE1U6
WINDB-P2 Wind Baffle - Large PACi and Mini ECOi Single Coil Side U-36LE1U6, U-52LE1U6, U-42PE1U6
WINDB-XE1 Wind Baffle - XE only Coil Side CU-XE9SKUA, CU-XE12SKUA, CU-XE15SKUA
WINDB-M2 Wind Baffle - Large Multi Coil Side CU-4E24RBU-5, CU-5E36QBU-5
CZ-MA1P-US-BUND Tube Size Reducer with Flare Nut (for multi-zone) CU-2E18SBU-5, CU-3E19RBU-5, CU-4E24RBU-5, CU-5E36QBU-5
CZ-MA2P-US-BUND Tube Size Reducer with Flare Nut (for multi-zone) CU-3E19RBU-5, CU-4E24RBU-5
CZ-MA3P-US-BUND Tube Size Reducer with Flare Nut (for multi-zone) CU-3E19RBU-5, CU-4E24RBU-5
AUXHTK1 Auxiliary Heater Relay Kit XE9WKUA, XE12WKUA, XE15WKUA, XE18WKUA, XE24WKUA
Line Set
Single Split Line Set Connection Chart (for Multi Split connections refer to Tube Adapter chart)
Insulation
LINE SET Liquid Line Suction Line Line Length
Thickness USE WITH
PART NUMBERS inch inch inch feet
DL04060815 1/4” x 3/8” x 1/2” x 15’ XE9WKUA, XE9SKUA, E9RKUA, RE9SKUA, YE9WKU1, YE12WKU1,
DL04060820 1/4” x 3/8” x 1/2” x 20’ KE12SBU, E9SD3UA, CU-2E18SBU-5, CU-3E19RBU-5,
DL04060835 1/4” x 3/8” x 1/2” x 35’ CU-4E24RBU-5, CU-5E36QBU-5
DL04080815* 1/4” x 1/2” x 1/2” x 15’ XE12WKUA, XE15SKUA, XE15WKUA, XE18WKUA, XE12SKUA,
DL04080820* 1/4” x 1/2” x 1/2” x 20’ E12RKUA, RE12SKUA, E12RB4U, E18RKUA, RE18SKUA, E18RB4U,
DL04080835* 1/4” x 1/2” x 1/2” x 35’ E12SD3UA, E18SD3UA, CU-4E24RBU-5, CU-5E36QBU-5
DL06100830 3/8” x 5/8” x 1/2” x 30’ All 26,000 through 42,000 Btu/hr Models
DL06100850 3/8” x 5/8” x 1/2” x 50’ All 26,000 through 42,000 Btu/hr Models
* Use Noted Lines Sets with CS-E24RKUAW
2 0 2 0 F U L L L I N E CATA LO G 57
Pipe Lengths, Fittings, Elevations
and Refrigerant
Maximum Elevation Difference Maximum Required
OD Tube Size (inches) Maximum Length of
SYSTEM SYSTEM between In/Outdoor (ft) ßLength (ft) Additional
Tubing between In/ Insulation
MODEL MODEL without Adding Refrigerant
Narrow Wide Outdoor (ft) Outdoor Above Outdoor Below Refrigerant Oz/ft
XE9WKUA 1/4 3/8 66 49 49 25 R410A 0.2 Both Tubes
XE12WKUA 1/4 1/2 66 49 49 25 R410A 0.2 Both Tubes
XE15WKUA 1/4 1/2 66 49 49 25 R410A 0.2 Both Tubes
XE18WKUA 1/4 1/2 100 49 49 33 R410A 0.2 Both Tubes
XE24WKUA 1/4 5/8 100 49 49 33 R410A 0.2 Both Tubes
26PEK2U6 3/8 5/8 165 100 50 100 R410A 0.43 Both Tubes
KE30NKUA 3/8 5/8 164 100 50 100 R410A 0.43 Both Tubes
KE36NKUA 3/8 5/8 164 100 50 100 R410A 0.43 Both Tubes
KS30NKUA 3/8 5/8 164 100 50 100 R410A 0.43 Both Tubes
KS36NKUA 3/8 5/8 164 100 50 100 R410A 0.43 Both Tubes
26PET2U6 3/8 5/8 165 100 50 100 R410A 0.43 Both Tubes
Ceiling
36PET2U6 3/8 5/8 165 100 50 100 R410A 0.43 Both Tubes
Suspended
42PET2U6 3/8 5/8 165 100 50 100 R410A 0.43 Both Tubes
XE9/12/15/18/24 Models Single Zone Professional Series (KS 30/36 NKU) Cooling Only Single Zone
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Maximum 89.6F DB / 73.4F WB 114.8F DB / 78.8F WB Maximum 95°F DB / 71°F WB 115°F DB
Cooling Cooling
Minimum 60.8F DB / 51.8F WB 0F DB / -F WB Minimum 67°F DB / 57°F WB 0°F DB
Maximum 86.0F DB / - WB 75°F DB / 64°F WB
Heating
Minimum 60.8F DB / - WB -15F DB / -16F WB CU-2E18NBU Multi Zone
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Exterios XE (CU-XE 9/12/15 SKUA) Single Zone
Maximum 89.6°F DB / 73.4°F WB 109.4°F DB / 78.8°F WB
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling
Minimum 60.8°F DB / 51.8°F WB 60.8°F DB / 51.8°F WB
Maximum 90°F DB / 74°F WB 115°F DB / 79°F WB Maximum 86°F DB / - WB 75.2°F DB / 64.4°F WB
Cooling Heating
Minimum 61°F DB / 52° WB 0°F DB / -° WB Minimum 60.8°F DB / - WB 5°F DB / 3.2°F WB
Maximum 86°F DB / -°F WB 75°F DB / 64°F WB
Heating
Minimum 61°F DB / -° WB -15°F DB / -16°F WB CU-2E18SBU-5 Multi Zone
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Exterios E (CU-E 9/12/18/24 RKUA) Single Zone
Maximum 90°F DB / 74°F WB 115°F DB / 79°F WB
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling
Minimum 61°F DB / 52°F WB 14°F DB / -°F WB
Maximum 90°F DB / 74°F WB 115°F DB / 79°F WB Maximum 86°F DB / - WB 75.2°F DB / 64.4°F WB
Cooling Heating
Minimum 61°F DB / 52°F WB 0°F DB / -° WB Minimum 61°F DB / - WB -5°F DB / -6.8°F WB
Maximum 86°F DB / -° WB 75°F DB / 64°F WB
Heating
Minimum 61°F DB / -° WB -5°F DB / -6.8°F WB CU-3E19RBU-5 / CU-4E24RBU-5 / CU-5E36QBU-5 Multi Zone
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Pro RE (CU-RE 9/12/18/24 SKUA) Single Zone
Maximum 89.6°F DB / 73.4°F WB 114.8°F DB / 78.8°F WB
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling
Minimum 60.8°F DB / 51.8°F WB 14°F DB / - WB
Maximum 90°F DB / 74°F WB 115°F DB / 79°F WB
Cooling
Minimum 61°F DB / 52°F WB 0°F DB / -° WB Maximum 86°F DB / - WB 75.2°F DB / 64.4°F WB
Heating
Maximum 86°F DB / -° WB 75°F DB / 64°F WB Minimum 60.8°F DB / - WB -5°F DB / -6.8°F WB
Heating
Minimum 61°F DB / -° WB -4°F DB / -5.8°F WB
Cooling
Maximum
Minimum
89.6F DB
62.6F DB
122.0F DB
5.0F DB
Single & Multi-Zone Wiring
Maximum 86.0F DB 86.0F DB
Heating
Minimum 32.0F DB -13F DB Indoor Unit 208 / 230V Outdoor Unit
Professional Series
(U- 26/36/42 PE1U6) Wall Mount PK / Ceiling Suspended PT /
4-Way Cassette PU / Ducted PF Single Zone
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Maximum 90˚F DB / 77˚F WB 115˚F DB / -˚ WB
Cooling
Minimum 64˚F DB / 57˚F WB 0˚F DB / -˚ WB
Maximum 86˚F DB / -˚ WB 75˚F DB / 64˚F WB
Heating
Minimum 61˚F DB / -˚ WB -4˚F DB / -4˚F WB
UL Listed or CSA approved 4 conductor wires minimum AWG16. Wiring size may vary based on length and should be verify with a licensed electrician.
Supply power and inter connecting wiring must be ran in separate conduits.
2 0 2 0 F U L L L I N E CATA LO G 59
Multi-Zone Tube Adapters
Model Number CU-5E36QBU-5
RAC
Indoor Unit Outdoor Unit System
C S – X E 1 2 S K U A C U – X E 1 2 S K U A E 1 2 S K U A
1 Series 2 Model/Type 3 Connection configuration 4 Function 5,6 Capacity 7 Development 8 Category (Type) 9 Voltage 10 Others
PAC
Indoor Unit Outdoor Unit Set
S – 26 P U 2 U6 U – 36 P E 1 U6 26 P E 2 U6
K: Wall Mount
U: Ceiling Recessed
S: Indoor unit
T: Ceiling suspended
Cooling Capacity in BTU/h P: Large Capacity series F: Concealed Duct Development Series U6: 208/230V 60Hz
S: Cooling Only
U: Outdoor Unit
E: Heat Pump
2 0 2 0 F U L L L I N E CATA LO G 61
NOTES
NOTES
Quality Certified to ISO 9001: 2008
Management Standard warranty - 7 years compressor/5 years parts.
System
Panasonic Appliance Air Conditioning
Certificate Malaysia Sdn.Bhd. For extended product warranty, please contact your local
Use of the AHRI Certified™ mark indicates Cert. No.: MY-AR 1010
a manufacture's participation in the
certification program. Certified to ISO 9001: 2008
Cert. No.: MY-AR 1010
authorized dealer for more information.
For verification of certification for individual
products, go to www.ahridirectory.org