PLDT EQUIPMENT INVENTORY CHECKLIST PSS

NPOB/CURBSIDE NAME (OLD): CABINET TYPE:

SITE NAME (NEW): CABINET BRAND:

Installed Equipment/s Cabinet Cooling System Condition Rectifier Condition


Node 1 Outside Dimension Type/Brand Rectifier Condition

# of Installed Rectifier Rating per


Node 2 Locking Mechanism ___good/____defective
module (ampreres)
Rectifier
Module
Key type/brand
Node 3 Rectifier Installation Date
Base pad height ___feet/ ____ meters
Node 4 Controller type Controller condition

Node 5 Hex (heat exchange ____good/ ___defective/


equipment) ___ no hex
Node 6 Rectifier Voltage
Canopy Reading Display Rectifier Load,A
clean/___dirty/___defective

Exhaust Fan Details Battery Condition


Indoor Battery
Ef1 Ef2 Condition
Type/Brand
Type/Brand Battery
Battery Capacity,
Installation AH
Model Date
Capacity # of Battery Battery
Strap __with/ ___
Serial Bank without

Status Grounding System Failed Pas


Ohms
AC POWER SYSTEM CHECK
Check ˂25Ω sed
Meter Thermostat/Timer
Check NPOB/Cabinet YES NO (Ω)
Base AC Conduit __ok/__not Earth Ground
1. Check Thermostat
Number Settings pipe condition okay Equipment
2. Test if Exhaust
Meter Fans__ok/ are functioning
AC Circuit
Base ___not breaker rating Chasis/Door
according to Temp settings __ok/__not
Condition
Other of ok
Ancillaries and condition okay Details ACU1 ACU2
3. Check relays thermostat/ACU timer YES NO
with4.
Canopy Fan
Resistanc AC CB Type/Brand
Check NPOB ACU Timer
e (ohms) Relocated to __yes/__no
with Ventilation Fan Equipment Side Model
with Overhead Cabinet Capacity
Good Fire Extinguisher? Status
Air-Con Unit

Equipment Check-up
Conducted by: __________________
__________________

NPOB Cabinet Thermostat/ Timer YES NO Encoded to Database By: Noted By:
1. Check Thermostat Settings

2. Test if Exhaust Fans are functioning


according to Temp settings
3. Check relays of thermostat/ACU timer
4. Check NPOB ACU Timer REMARKS:

Time In/Out: ____________________


Check-Up Date: ____________________
Interior Of Cabinet/NPOB

PLDT PMS CHECKLIST PSS


NPOB/CURBSIDE NAME (OLD): ________________________
PMS Date: _______________________
Curbside PMS Activity Check Box YES NO Time In/Out: _______________________
Exterior of Cabinet Cabinet Type: ________________________
1. Check and inspect
vandalized/corroded cabinet.
2. Check and inspect damaged SITE NAME (NEW):
cabinet bollards.
3. Check and inspect key holder.
External Alarms Simulation Test YES NO
4. Check and inspect cabinet
basepad. 1. Battery assumed load.
5. Check and inspect power entrance 2. AC Main Alarm Monitored.
cable. 3. Rectifier Alarm Monitored
6. Check and inspect power circuit 4. Temperature Alarm Monitored.
breaker. 5. Battery theft Alarm Monitored.
7. Cleaning and washing dirty cabinet 6. Door Open Alarm Monitored.
using detergent.

AC Power System Check


INTERIOR OF CABINET/NPOB
1. Dusting and vacuuming CB Rating: AC Load:
2. Cleaning/Replacement of Meter Brand: Model:
Fans/Heat exchanger Phase: Meter No.
3. Cleaning of Node and filters
4. Check and inspect cabinet
grounding
5. Check and inspect elect’l sys. Inc
breakers
6. Check and inspect & reading AC
power
7. Check and inspect & reading
rectifier
8. Check and inspect & reading
Batteries
9. Visual inspection of busbar
condition.

Cabinet Parameter (1 meter radius)

1. Grass cutting?
2. Cleaning/Removal of obstructions?
3. With ingress/egress for
rodents/insects?
4. Complete Cabinet door?

DC Power System Rectifier


Unit No. Brand/Model Rating Total Load Condition Remarks:
(AMP) (A)
1
2
3
4
Controller:
DC Power System Check BATTERY
No of Brand/Model Typ Capacity Volt Year Condition Remarks
Banks e s Installed

1
Encoded to
Database by: Noted by:
2

PMS REMARKS:
Conducted by: _______________________