0% found this document useful (0 votes)
170 views12 pages

8 Channel Decoder & Zone Selector PDF

This document provides an instruction manual for the TD6080 8 Channel Decoder/Zone Selector. It identifies the main parts of the unit including inputs for DC power, paging microphones, and a mixer. It also describes the zone output connections, unit addressing switches, and an emergency override terminal. The general schematic diagram shows how the unit can be used to decode audio signals from multiple paging microphones to specific zones connected to amplifiers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
170 views12 pages

8 Channel Decoder & Zone Selector PDF

This document provides an instruction manual for the TD6080 8 Channel Decoder/Zone Selector. It identifies the main parts of the unit including inputs for DC power, paging microphones, and a mixer. It also describes the zone output connections, unit addressing switches, and an emergency override terminal. The general schematic diagram shows how the unit can be used to decode audio signals from multiple paging microphones to specific zones connected to amplifiers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

INSTRUCTION MANUAL

TD6080
8 Channel Decoder / Zone Selector

Thank you for choosing another quality product from Amperes Electronics.

TD6080 is an integration of mic data decoder and zone selector in a box, which simplifies the interconnection works during rack
setup. Apart from simplification, a substantial cost reduction can be achieved due to lower unit count and space requirement as
compared to setup using zone decoder and zone selector.

We appreciate that you read through the manual to avoid any mishandling as well as to explore the full potential this unit can
offer. Keep this manual for future reference and we believe that you are getting an optimum product in its class.

VER 3 / 2015
Parts Identification

Front View:
1 2 3

Rear View:

4 5 6 7 8 9 10
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

1. LED INDICATORS
POWER LED for DC input and ACTIVE for zone activation.

2. ALL CALL SWITCH


All zones will be activated by pressing this switch, regardless of any inactive zone.

3. FRONT PANEL ZONE SWITCH - ZONE 1 - 8


Switching for zone 1 to 8. For grouping of zones using matrix, please refer to page 7.

4. DC SUPPLY INPUT
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is recommeded
that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as a DC supply source to your
installation.

5. PAGING MIC INPUT


The connectors are to link to paging mics via EX2800 using 2 pair screen cable or from paging Mic using RJ45 connector.

6. MIXER INPUT
BGM source from mixer output. This shall be used when there is audio (BGM) grouping in the system for zones
of the decoder.

7. AUDIO OUTPUT
Audio output from the decoder is balanced line output level. RJ45 connector consists of audio, data and power with the
following pin configuration:-

Pin 1 - Data A Pin 5 - +24V Supply


Pin 2 - Data B Pin 6 - Audio -ve output
Pin 3 - Relay Trigger Signal Pin 7 - Ground
Pin 4 - NC Pin 8 - Audio +ve Output

PAGE 2 TD6080 | 8 CH DECODER / ZONE SELECTOR


Parts Identification ( Con’t )

8. UNIT ADDRESS DIP SWITCHES


Each decoder caters for 8 channel outputs, thus each DIP setting shall comprise address for a gorup of 8 channels.
Address setting shall be using BCD codes.
Example:
DIP SWITCH 1 TO 8 DIP SWITCH 6 DIP SWITCH 7 DIP SWITCH 8
1000 0000 - Zone 1 to 8 ON = TIMER 5 MIN ON = MIC OUTPUT ON = MASTER (CH 1 - CH8)
0100 0000 - Zone 9 to 16 OFF = TIMER INFINITY OFF = LINE OUTPUT OFF = SLAVE (CH 9 - CH248)
1100 0000 - Zone 17 to 24

9. EMERGENCY OVERRIDE TERMINAL


External switch ( eg. fr emergency paging mic with dry contact ) can be connected here, which shall trigger the built in
relay when pressed. This shall then provide a dry contact in which would enable the installer to apply several functions
such as providing 24V DC output for volume controller overriding purpose, trigger external device or link to BAS
system, etc. Refer to page 10 for connection diagram.

10. AMPLIFIER ZONE OUTPUT CONNECTOR ( ZONE 1 - 8 )


Outputs from amplifiers are connected to these terminals and speaker zoning is configured to the respective
unit of amplifier. The user has the flexibility to configure the zoning system as each zone comes with single amplifier
output connection. Please observe polarity when terminating the amplifier / speaker zones and ensure that each
zone is not over overloaded ( max load 500W l00V line ).

TD6080 | 8 CH DECODER / ZONE SELECTOR PAGE 3


General Schematic Diagram

PD2400 / 2800 The illustration using multiple paging mic


PAGING MIC 2 with TD6080 as zone decoder and zone
selector
PD2400 / 2800
PAGING MIC 1

PD2400 / 2800
PAGING MIC 3
Cat 5e

EX1103

audio & data


2pr screen

TD6080
DECODER Zone Output

audio output
(mic / line level)
MX2222
PREAMPLIFIER MIXER Amp (100V Line) ------------------
O/P
OFF SELECT POWER
CH1 CH2 CH3 CH4 CH5 CH6 SOURCE MASTER
EXT INPUT TONE CTRL

I
MX 2122 OFF
TUNER
CD
CASS
AUX
a m pe re s

MIN MAX MIN MAX


O
CHIME MIXER TREBLE BASS
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX

SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN MUSIC SOURCE

audio
output

POWER

MENU

I
QP2500 a m pe re s

O
UP

DOWN

Zone 1 Zone 8
SPEAKERS
500W 100V LINE POWER AMPLIFIER

POWER AMPLIFIER
QP2000S

Note:

All PD Series of Amperes paging microphones can be used with TD6080.

PAGE 4 TD6080 | 8 CH DECODER / ZONE SELECTOR


Connecting The Unit - Single Unit Installation

For Single unit paging mic, set priority level


to 0 (PD2800) or 00 (PD2400). Priority 1 is
highest.
Remote location
Rear view of PD2800

Cat5e

TD6080
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

Audio out (balanced)


Select Mic (DIP switch 7)
100V
MX2222

EP1200A
--------
--------

100V Output

QP2500

Zone 1 Zone 8
SPEAKERS

Note:

Also refer to page 10, in using EP1200A to trigger emergency overriding at volume controllers.

TD6080 | 8 CH DECODER / ZONE SELECTOR PAGE 5


Connecting The Unit - Multipoint Paging Installations

PD2400 / 2800

PD2800
Paging Microphone

MIN MAX MIN MAX Quality Product From


AMPERES ELECTRONICS

Cat5e

PD2400 / 2800
PD2400 / 2800
PD2800
Paging Microphone

MIN MAX MIN MAX Quality Product From


AMPERES ELECTRONICS

PD2800
Paging Microphone

MIN MAX MIN MAX Quality Product From


AMPERES ELECTRONICS

24V DC

Cat5e
EX2800
EX1103

OUTPUT

INPUT
MIC EXTENDER
24V DC

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

TD6080

2 pair screen cable


18 AWG cable size is recommended For long distance only

Note :

1) Use EX1103A if more than one PD2400 / 2800 are available in the system. The single output (RJ45) can
be directly connected to TD6080 mic input port.

2) A higher priority mic shall override any lower priority unit in active.

PD2400 :
3 levels of priority available for PD2400.

PD2800 :
9 levels of priority available for PD2800.

PAGE 6 TD6080 | 8 CH DECODER / ZONE SELECTOR


Connecting The Unit - BGM Grouping (Matrix)

Paging data & audio


Matrix
Master
Group 1
TIME OUT 5 MIN
LINE / MIC OUTPUT

1
Music
MASTER / SLAVE

0 L S

DC 24V 5 M M

Audio &
Data Link

Slave
TIME OUT 5 MIN

57
Music
LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

Group 8 64
BGM 2

Detailed BGM Grouping

To power amp. input (Group 1)

From amplifier output

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

Unit 1 (master)
Output from to zone speaker
matrix (zone 1 & 8)
Link (Group 1)

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

Unit 2 (slave)
To power amp. input (Group 2) to zone speaker
(Group 2)
(zone 9 & 16)

Application Note:

1) This configuration shall be and whenever grouping of zones is required.


e.g: zone 1 to zone 8 to have same BGM input, Group 1 and so forth.

2) Paging made to a zone in the same group shall mute other zone within the group but would not interrupt zones in
other groups.

3) This setup would normally be used together with matrix controller.

4) Use of DA2208 at paging mic audio output is required if more than 6 amplifiers are installed in the system.

TD6080 | 8 CH DECODER / ZONE SELECTOR PAGE 7


Connecting The Unit - iPX5151 ip Client

PD SERIES PAGING MIC iPX5151


PD2800 PAGING CLIENT

}
24V DC EX2800
OUTPUT

INPUT

}
Network Switch

iPX5151
PAGING CLIENT

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

TD6080

Line Out
100V
SPEAKERS

QP2500

PAGE 8 TD6080 | 8 CH DECODER / ZONE SELECTOR


Cascading The Units

AMPLIFIER

From paging microphone


Audio
Data

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

1, 8 ON
Only link master Z1~Z8
the Data

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

2 ON
Only link slave Z 9 ~ Z 16
the Data

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

1, 2 ON
slave Z 17 ~ Z 24

Set unit address :

example : 10000 0000 - Zone 1 to 8 (DIP Switch 8 ON)


01000 0000 - Zone 9 to 16 (DIP Switch 8 OFF)
11000 0000 - Zone 17 to 24 (DIP Switch 8 OFF)

TD6080 | 8 CH DECODER / ZONE SELECTOR PAGE 9


Overriding Volume Controls

TIME OUT 5 MIN


LINE / MIC OUTPUT
MASTER / SLAVE

0 L S

DC 24V 5 M M

24V DC +ve VC

- ve

Note:

Trigger of ‘ALL CALL’ button at TD6080 front panel shall ON all zones but would not be able to override volume controllers.
This is to avoid unnecessary announcement or BGM to be broadcasted to the selected zones.

EP1200A can be used, in case of emergency paging to override the volume controllers by using the above configuration.

PAGE 10 TD6080 | 8 CH DECODER / ZONE SELECTOR


Technical Data

Operating voltage 24V DC


Consumption 6W (250 mA)
Max load / channels 500W at 100V line
Cascade limitation 31 Unit (248 zone)
Input circuit 2
Number of zone 8
Amplifier input 8
Zone selection Front panel switch & remote
Indicators Individual zone switch
Switch mode Individual, All Call Local
zone selection bypassed when remote trigger is actived
AUDIO
Input impedance (Ohm) Line : 10 K
Output impedance 600 Ohm balanced
Freq response 70 ~ 15 KHz
Audio input Line
Max audio output Line 1.2V

DATA
Data protocol RS485
Baud rate 19.2 K bps
Dimension (WxHx D) 482 x 44 x 180 mm
Weight 2 kg

Note:

The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.

TD6080 | 8 CH DECODER / ZONE SELECTOR PAGE 11


Warranty Conditions
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics
Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan
Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized
master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are
performed by unauthorized personnel or service centres.

This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as
removal and installation of the product from the main system are for the account of the purchaser. This warranty
shall not extend to the replacement of the unit.

This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the
product with power supply voltage other than shown on the product, or any other power supply source / adaptor
not recommended by the manufacturer.

This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly
related to the unit.

This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the
unit; moreover the warranty does not cover any damages which may be caused to people and things when using
the product.

This warranty certificate is valid only for the described product, and is not valid if modifications are made on this
certificate or on the identification label applied on the product.

This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the
date of purchase or for a longer period in countries where this is stated by a national law. In this case, the
extension is valid only in the country where the product is purchased.

Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the
design changes or improvements are made.

Disclaimer
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or
damages whatsoever arising from the use of information or any error contained in this manual.

It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN
BHD or its authorized service agents.

AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction
with this operating manual.

AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by
service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.

AMPERES ELECTRONICS SDN BHD


ISO 9001: 2008 MADE IN MALAYSIA
Design & Manufacture of Public Address Equipment and Systems
Certificate No. 16895 / A / 0001 / UK / En Published : MAY 2015

You might also like