8 Channel Decoder & Zone Selector PDF
8 Channel Decoder & Zone Selector PDF
TD6080
8 Channel Decoder / Zone Selector
Thank you for choosing another quality product from Amperes Electronics.
TD6080 is an integration of mic data decoder and zone selector in a box, which simplifies the interconnection works during rack
setup. Apart from simplification, a substantial cost reduction can be achieved due to lower unit count and space requirement as
compared to setup using zone decoder and zone selector.
We appreciate that you read through the manual to avoid any mishandling as well as to explore the full potential this unit can
offer. Keep this manual for future reference and we believe that you are getting an optimum product in its class.
VER 3 / 2015
Parts Identification
Front View:
1 2 3
Rear View:
4 5 6 7 8 9 10
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0 L S
DC 24V 5 M M
1. LED INDICATORS
POWER LED for DC input and ACTIVE for zone activation.
4. DC SUPPLY INPUT
24V DC supply is required to operate this unit. Ensure polarity is correctly terminated to the port. It is recommeded
that supply with 1A rating of regulated source is used. Amperes PS9400 is recommended as a DC supply source to your
installation.
6. MIXER INPUT
BGM source from mixer output. This shall be used when there is audio (BGM) grouping in the system for zones
of the decoder.
7. AUDIO OUTPUT
Audio output from the decoder is balanced line output level. RJ45 connector consists of audio, data and power with the
following pin configuration:-
PD2400 / 2800
PAGING MIC 3
Cat 5e
EX1103
TD6080
DECODER Zone Output
audio output
(mic / line level)
MX2222
PREAMPLIFIER MIXER Amp (100V Line) ------------------
O/P
OFF SELECT POWER
CH1 CH2 CH3 CH4 CH5 CH6 SOURCE MASTER
EXT INPUT TONE CTRL
I
MX 2122 OFF
TUNER
CD
CASS
AUX
a m pe re s
SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN SIG IN MUSIC SOURCE
audio
output
POWER
MENU
I
QP2500 a m pe re s
O
UP
DOWN
Zone 1 Zone 8
SPEAKERS
500W 100V LINE POWER AMPLIFIER
POWER AMPLIFIER
QP2000S
Note:
Cat5e
TD6080
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0 L S
DC 24V 5 M M
EP1200A
--------
--------
100V Output
QP2500
Zone 1 Zone 8
SPEAKERS
Note:
Also refer to page 10, in using EP1200A to trigger emergency overriding at volume controllers.
PD2400 / 2800
PD2800
Paging Microphone
Cat5e
PD2400 / 2800
PD2400 / 2800
PD2800
Paging Microphone
PD2800
Paging Microphone
24V DC
Cat5e
EX2800
EX1103
OUTPUT
INPUT
MIC EXTENDER
24V DC
0 L S
DC 24V 5 M M
TD6080
Note :
1) Use EX1103A if more than one PD2400 / 2800 are available in the system. The single output (RJ45) can
be directly connected to TD6080 mic input port.
2) A higher priority mic shall override any lower priority unit in active.
PD2400 :
3 levels of priority available for PD2400.
PD2800 :
9 levels of priority available for PD2800.
1
Music
MASTER / SLAVE
0 L S
DC 24V 5 M M
Audio &
Data Link
Slave
TIME OUT 5 MIN
57
Music
LINE / MIC OUTPUT
MASTER / SLAVE
0 L S
DC 24V 5 M M
Group 8 64
BGM 2
0 L S
DC 24V 5 M M
Unit 1 (master)
Output from to zone speaker
matrix (zone 1 & 8)
Link (Group 1)
0 L S
DC 24V 5 M M
Unit 2 (slave)
To power amp. input (Group 2) to zone speaker
(Group 2)
(zone 9 & 16)
Application Note:
2) Paging made to a zone in the same group shall mute other zone within the group but would not interrupt zones in
other groups.
4) Use of DA2208 at paging mic audio output is required if more than 6 amplifiers are installed in the system.
}
24V DC EX2800
OUTPUT
INPUT
}
Network Switch
iPX5151
PAGING CLIENT
0 L S
DC 24V 5 M M
TD6080
Line Out
100V
SPEAKERS
QP2500
AMPLIFIER
0 L S
DC 24V 5 M M
1, 8 ON
Only link master Z1~Z8
the Data
0 L S
DC 24V 5 M M
2 ON
Only link slave Z 9 ~ Z 16
the Data
0 L S
DC 24V 5 M M
1, 2 ON
slave Z 17 ~ Z 24
0 L S
DC 24V 5 M M
24V DC +ve VC
- ve
Note:
Trigger of ‘ALL CALL’ button at TD6080 front panel shall ON all zones but would not be able to override volume controllers.
This is to avoid unnecessary announcement or BGM to be broadcasted to the selected zones.
EP1200A can be used, in case of emergency paging to override the volume controllers by using the above configuration.
DATA
Data protocol RS485
Baud rate 19.2 K bps
Dimension (WxHx D) 482 x 44 x 180 mm
Weight 2 kg
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as
removal and installation of the product from the main system are for the account of the purchaser. This warranty
shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the
product with power supply voltage other than shown on the product, or any other power supply source / adaptor
not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly
related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the
unit; moreover the warranty does not cover any damages which may be caused to people and things when using
the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on this
certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the
date of purchase or for a longer period in countries where this is stated by a national law. In this case, the
extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the
design changes or improvements are made.
Disclaimer
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or
damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN
BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction
with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by
service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.