DEPARTMENT OF STRUCTURAL ENGINEERING

M B M ENGINEERING COLLEGE
FACULTY OF ENGINEERING & ARCHITECTURE, JAI NARAIN VYAS UNIVERSITY, JODHPUR
No. JNVU/FE/PSE/2019-20/ 1109 Date: 2/9/2020
To,
Executive Engineer,
Public Works Department,
Dn Gudamalani, Barmer.
Sub: Testing Report of Reinforcement Steel Bars of 10 mm (JSW NEO STEEL 500D)
Ref: Your Letter No. 591 dated 26.8.2020
Sir,
The sample received by the party, has been tested in the laboratory as per relevant IS and the following results have been found:
TENSION TEST
S. No. Nominal Nominal Gauge length 0.2 % Proof Ultimate Stress % Remarks
Dia. (mm) Area (mm2) (mm) Stress (N/mm2) (N/mm2) Extension
1 10 74.53 50 525.40 626.90 22.0 Star fracture
2 10 74.48 50 531.73 639.27 24.0 Partial cup and cone fracture
3 10 75.37 50 525.45 637.63 22.0 Partial cup and cone fracture
COLD BEND TEST
S. No. Nominal Dia. (mm) Remarks
1 10 No cracks on the external surface of U-Bend
2 10 No cracks on the external surface of U-Bend
3 10 No cracks on the external surface of U-Bend
UNIT WEIGHT TEST
S. No. Nominal Dia. (mm) Length (mm) Weight (kg) Unit Weight (kg/m) IS: 1786Value (kg/m)
1 10 1005 588 0.610 0.617
2 10 1004 587 0.608 0.617
3 10 1004 594 0.612 0.617

COUNTERSIGNED

(Dr. Ajay Sharma) (Dr. Archana Bohra Gupta)


Testing Incharge Testing Incharge
(Dr. Ajay Sharma)
HEAD
DEPARTMENT OF STRUCTURAL ENGINEERING
M B M ENGINEERING COLLEGE
FACULTY OF ENGINEERING & ARCHITECTURE, JAI NARAIN VYAS UNIVERSITY, JODHPUR
No. JNVU/FE/PSE/2019-20/ 1109 Date: 2/9/2020
To,
Executive Engineer,
Public Works Department,
Dn Gudamalani, Barmer.
Sub: Testing Report of Reinforcement Steel Bars of 12 mm (JSW NEO STEEL 500D)
Ref: Your Letter No. 591 dated 26.8.2020
Sir,
The sample received by the party, has been tested in the laboratory as per relevant IS and the following results have been found:
TENSION TEST
S. No. Nominal Nominal Gauge length 0.2 % Proof Ultimate Stress % Remarks
2 2 2
Dia. (mm) Area (mm ) (mm) Stress (N/mm ) (N/mm ) Extension
1 12 112.36 60 506.92 633.65 23.33 Partial cup & cone fracture
2 12 111.59 60 514.41 638.02 21.67 Star fracture
3 12 112.61 60 509.75 632.24 21.67 Star fracture
COLD BEND TEST
S. No. Nominal Dia. (mm) Remarks
1 12 No cracks on the external surface of U-Bend
2 12 No cracks on the external surface of U-Bend
3 12 No cracks on the external surface of U-Bend
UNIT WEIGHT TEST
S. No. Nominal Dia. (mm) Length (mm) Weight (kg) Unit Weight (kg/m) IS: 1786Value (kg/m)
1 12 1001 0.883 0.882 0.888
2 12 1000 0.876 0.876 0.888
3 12 1005 0.888 0.884 0.888

COUNTERSIGNED

(Dr. Ajay Sharma) (Dr. Archana Bohra Gupta)


Testing Incharge Testing Incharge
(Dr. Ajay Sharma)
HEAD
DEPARTMENT OF STRUCTURAL ENGINEERING
M B M ENGINEERING COLLEGE
FACULTY OF ENGINEERING & ARCHITECTURE, JAI NARAIN VYAS UNIVERSITY, JODHPUR
No. JNVU/FE/PSE/2019-20/ 1109 Date: 2/9/2020
To,
Executive Engineer,
Public Works Department,
Dn Gudamalani, Barmer.
Sub: Testing Report of Reinforcement Steel Bars of 16 mm (JSW NEO STEEL 500D)
Ref: Your Letter No. 591 dated 26.8.2020
Sir,
The sample received by the party, has been tested in the laboratory as per relevant IS and the following results have been found:
TENSION TEST
S. No. Nominal Nominal Gauge length 0.2 % Proof Ultimate Stress % Remarks
2 2 2
Dia. (mm) Area (mm ) (mm) Stress (N/mm ) (N/mm ) Extension
1 16 190.19 80 514.73 631.71 23.75 Partial cup & cone fracture
2 16 190.70 80 518.01 634.69 22.50 Star fracture
3 16 194.33 80 510.63 627.41 22.50 Star fracture
COLD BEND TEST
S. No. Nominal Dia. (mm) Remarks
1 16 No cracks on the external surface of U-Bend
2 16 No cracks on the external surface of U-Bend
3 16 No cracks on the external surface of U-Bend
UNIT WEIGHT TEST
S. No. Nominal Dia. (mm) Length (mm) Weight (kg) Unit Weight (kg/m) IS: 1786Value (kg/m)
1 16 1000 1.493 1.572 1.580
2 16 1000 1.497 1.578 1.580
3 16 1001 1.527 1.570 1.580

COUNTERSIGNED

(Dr. Ajay Sharma) (Dr. Archana Bohra Gupta)


Testing Incharge Testing Incharge
(Dr. Ajay Sharma)
HEAD
DEPARTMENT OF STRUCTURAL ENGINEERING
M B M ENGINEERING COLLEGE
FACULTY OF ENGINEERING & ARCHITECTURE, JAI NARAIN VYAS UNIVERSITY, JODHPUR
No. JNVU/FE/PSE/2019-20/ 1109 Date: 2/9/2020
To,
Executive Engineer,
Public Works Department,
Dn Gudamalani, Barmer.
Sub: Testing Report of Reinforcement Steel Bars of 20 mm (JSW NEO STEEL 500D)
Ref: Your Letter No. 591 dated 26.8.2020
Sir,
The sample received by the party, has been tested in the laboratory as per relevant IS and the following results have been found:

TENSION TEST
S. No. Nominal Nominal Gauge length 0.2 % Proof Ultimate Stress % Remarks
2 2 2
Dia. (mm) Area (mm ) (mm) Stress (N/mm ) (N/mm ) Extension
1 20 313.53 100 510.93 617.55 20.0 Shear fracture
2 20 312.81 100 512.11 625.91 22.0 Star fracture
3 20 312.72 100 505.14 628.94 21.0 Star fracture
COLD BEND TEST
S. No. Nominal Dia. (mm) Remarks
1 20 No cracks on the external surface of U-Bend
2 20 No cracks on the external surface of U-Bend
3 20 No cracks on the external surface of U-Bend
UNIT WEIGHT TEST
S. No. Nominal Dia. (mm) Length (mm) Weight (kg) Unit Weight (kg/m) IS: 1786Value (kg/m)
1 20 1006 2.476 2.461 2.470
2 20 1001 2.458 2.466 2.470
3 20 1007 2.472 2.465 2.470

COUNTERSIGNED

(Dr. Ajay Sharma) (Dr. Archana Bohra Gupta)


Testing Incharge Testing Incharge

(Dr. Ajay Sharma)


HEAD