SG60KTL PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SG60KTL

String Inverter

High Yield Easy O&M


Max. efficiency 98.9 %, European efficiency 98.7 % Compact design and light weight for easy
Long-term overload at 1.1 Pn installation
Full power operation without derating at 50 ℃ Plug-in design of fan and SPD, convenient for
on-site maintenance
Integrated string current monitoring function for
fast trouble shooting

Saved Investment Grid Support


Max. DC/AC ratio up to 1.4 Compliance with standards: IEC 62109, IEC
Integrated DC combiner box and DC/AC 61727, IEC 62116, VDE0126-1-1, G59/3,
overvoltage protection VDE-AR-N-4105, VDE-AR-N-4120, BDEW
Low/High voltage ride through (L/HVRT)
Active & reactive power control and power
ramp rate control

Circuit Diagram Efficiency Curve

100%
DC Fuse
1 98%
2
3

96%
Efficiency

14 L1
DC EMI AC AC AC EMI
DC L2
Filter Filter Relays Filter 94% Vdc=570 V
1
2 L3 Vdc=710 V
3
92%
14
N Vdc=850 V

Current DC DC SPD DC Bus Inverter Circuit AC SPD PE


90%
Monitoring Switch (DC/AC) 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Normalized Output Power

© 2017 Sungrow Power Supply Co., Ltd. All rights reserved.


Subject to change without notice. Version 1.1
SG60KTL

Input (DC) SG60KTL


Max. PV input voltage 1000 V
Min. PV input voltage / Startup input voltage 570 V / 620 V
Nominal input voltage 710 V
MPP voltage range 570 – 950 V
MPP voltage range for nominal power 570 – 850 V
No. of independent MPP inputs 1
Max. number of PV strings per MPPT 14
Max. PV input current 120 A
Max. current for input connector 12 A
Max. DC short-circuit current 140 A

Output (AC)
Nominal AC power (at 50 ˚C) 60000 W
Max. AC output power at PF=1 (at 45 ˚C) 66000 W
Max. AC apparent power (at 45 ˚C) 66000 VA
Max. AC output current 96 A
Nominal AC voltage 3 / N / PE or 3 / PE, 230 / 400 V
AC voltage range 310 – 480 V
Nominal grid frequency / Grid frequency range 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD < 3 % (at nominal power)
DC current injection < 0.5 % In
Power factor at nominal power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases 3/3

Efficiency
Max. efficiency / Euro. efficiency 98.9 % / 98.7 %

Protection
DC reverse connection protection Yes
AC short-circuit protection Yes
Leakage current protection Yes
Grid monitoring Yes
DC switch / AC switch Yes / No
DC fuse Yes (positive, 15A)
PV string current monitoring Yes
Overvoltage protection DC Type II / AC Type III

General Data
Dimensions (W*H*D) 634*959*267 mm
Weight 60 kg
Isolation method Transformerless
Degree of protection IP65
Night power consumption <1W
Operating ambient temperature range -25 to 60 ℃ (> 50 ℃ derating)
Allowable relative humidity range (non-condensing) 0 – 100 %
Cooling method Smart forced air cooling
Max. operating altitude 4000 m (> 3000 m derating)
Display / Communication Graphic LCD / RS485
DC connection type MC4 (Max. 6mm²)
AC connection type Screw clamp terminal (Max. 95 mm² )
Compliance CEA, IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683,
VDE0126-1-1, G59/3, VDE-AR-N-4105, VDE-AR-N-4120, BDEW,
IEC 61000-3-11/-12, EN 50438, UTE C 15-712-1/07.13
Grid support LVRT, HVRT, active & reactive power control and power ramp
rate control
Type designation SG60KTL-182

© 2017 Sungrow Power Supply Co., Ltd. All rights reserved.