Date Dsn. by Chk. by Design Sheet Rev. No.: Web Flange Weld

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Date 06-Jun-06

Web Flange Weld Dsn. By ZAS


Chk. By SKK
Design Sheet Rev. No. 0






       
        
 

        

Section Data
Width Thk. Area of Compressio
Top Flange (tf1) = 250 10 mm Area of web in com
Web (dw) = 1000 8 mm
Bottom Flange (tf2) = 250 10 mm

Weld Data
For E70XX Electrode (Fu) = 48.23 kN/cm2
Allowable Stress in weld = 0.3 x Fu kN/cm2
Allowable Stress in weld = 14.47 kN/cm2
Sw = 12 mm Size of Weld
Number of Weld Side = 1

Ts = Shear Stress in Weld (kN/cm2)


F= 130 kN Shear Force. (kN)
Ixx = 194183 cm4 Moment of Inertia
b= 0.85 cm Width of the weld at the weld section (0.707 x Sw)
A y = 1262.50 cm3 Moment of area of flange above
the fibre under consideration.

Stress in Beam Shear ( Ts ) = F A y / Ixx b


= 1.00 kN/cm2 Hence OK
Date 14-Jun-16
Web Flange Weld Dsn. By KMA
Chk. By KMA
Design Sheet Rev. No. 1
AS PER: AWS D1.1/D1.1M:2004







       
        
 

        

Section Data
Width Thk.
Top Flange (tf1) = 150 6 mm
Web (dw) = 350 5 mm
Bottom Flange (tf2) = 150 6 mm

Weld Data
For E60XX Electrode (Fu) = 41.34 kN/cm2
Allowable Stress in weld = 0.3 x Fu kN/cm2
Allowable Stress in weld = 12.40 kN/cm2
Sw = 3 mm Size of Weld
Number of Weld Side = 1

Ts = Shear Stress in Weld (kN/cm2)


F= 31 kN Shear Force. (kN)
Ixx = 7490 cm4 Moment of Inertia
b= 0.21 cm Width of the weld at the weld section (0.707 x S w)
Ay= 160.20 cm3 Moment of area of flange above
the fibre under consideration.

Stress in Beam Shear ( Ts ) = F A y / Ixx b


= 3.13 kN/cm2 Hence OK

Intermittent Weld Clarification:

The Specification of Intermittent Weld are as follows:


a. Effective length of each intermittent weld is= 38 mm
b. Pitch (p) of intermittent weld: The clear spacing of intermittent weld should not exceed
a 24x thickness of thinner part = 120 mm
b will not exceed 300 mm= 300 mm
hence for 120 mm clear spacing between the weld,p= 158.00 mm
This is the maximum spacing. However , The spacing or pitch should be such that the shear in the weld is not
more than Ts (Shear Stress)
strength of weld per linear meter (consider both side) 5.26 KN/cm
use 38 mm long intermittent weld on both side of web plate, weld strength = 19.99 KN/cm
weld spacing,p 6.40 cm
63.95 mm