Protection with Sika® FerroGard®-903 both delays the start of corrosion and
®
reduces the corrosion rate. Corrosion protection with Sika® FerroGard -903
Construction
increases the service and maintenance life cycles by up to 15 years when used as
a part of a complete Sika Concrete Repair and Protection System.
Uses For the corrosion protection of steel reinforced concrete structures above and
below the ground
As a corrosion control treatment for undamaged reinforced concrete where
reinforcing steel is corroding, or is at risk from corrosion due to the effects of
carbonated or chloride contaminated concrete.
Sika® Ferrogard®-903 is especially suitable for extending the service life of
aesthetically valuable fair-faced concrete surfaces such as historic structures.
Characteristics / Complies to principle 11 of EN 1504-9 method 11.3 (applying inhibitor to the
Advantages concrete).
Does not change the appearance of the concrete structure
Does not alter the water vapour diffusion properties of concrete.
Long term protection and durability
Can be applied to the surface of existing repairs and to surrounding areas to
prevent the development of incipient anodes
Protects both, cathodic (principle 9) and anodic (principle 11) zones of
reinforcing steel
Can be applied where other repair/prevention options are not viable
Economical extension of the service life of reinforced concrete structures.
Easy, economical application, renewable
Can be used as part of a simple yet effective concrete repair and protection
system
Penetration depth can be tested on site using the Sika “Qualitative Analysis
Test”- refer to your local Technical Service Department for details
Test Certificates BRE, The use of surface applied FerroGard 903+ corrosion inhibitor to delay
the onset of chloride induced corrosion in hardened concrete, BRE Client
Report No. 224-346, 2005
Mott MacDonald, Evaluation of Sika FerroGard, Ref. 26’063/001 Rev. A April
1996.
SAMARIS (Sustainable and Advanced Materials for Road Infrastructure) –
Final Report, Deliverables D17a, D17b, D21 & D25a, Copenhagen, 2006
Mulheron, M., Nwaubani, S.O. , Corrosion Inhibitors for High Performance
Reinforced Concrete Structures, University of Surrey, 1999
C-Probe Systems Ltd., Performance of Corrosion Inhibitors in Practice, 2000
®
Sika Ferrogard -903 has been tested as per SCAQMD Rule 1168'
Result VOC Content < 25 g/L
Product Data
Colour Transparent liquid.
Packaging 5 kg and 20 kg pails
200 kg drums
Bulk Tanks packing available upon request
Storage/ Shelf Life Stored in unopened original containers in cool conditions, shelf life is at least 12
months from date of production.
- Aluminium, copper, galvanised steel, marble and other similar natural stone
Visible concrete defects (spalling, cracks etc) must be repaired using conventional
repair methods (removal of delaminating or loose concrete, treatment of
reinforcement, reprofiling etc.)
All surface treatments are to be carried out using cold potable water.
Data Sheet for the product concerned, copies of which will be supplied on request.