CanoScan Lide 20 Lide 30 Quick Start Guide EN
CanoScan Lide 20 Lide 30 Quick Start Guide EN
CanoScan Lide 20 Lide 30 Quick Start Guide EN
!
"
1
Guide to the Manuals
Use of a shielded cable with the ferrite core(s) provided with the scanner is necessary to comply with the technical
requirements of the EMC Directive.
Warning
When you use this product, you should pay attention to the following legal issues:
• Scanning of certain documents, such as bank notes (bank bills), government bonds and public certificates, may be prohibited by
law and may result in criminal and/or civil liability.
• You may be required under law to obtain authorization from a person possessing copyrights or other legal rights to the item
being scanned.
If you are uncertain of the legality of scanning any particular item, you should consult your legal adviser in advance.
In this guide the screen shots are taken with Windows XP in the explanation common to all operating systems.
2
Check the Package Contents
English
Scanner and Accessories
Stand
Page 12
Adobe Acrobat Reader (24 MB / 24 MB) - Electronic Manual Viewer Program (PDF manual)
Electronic manuals for the above software programs (HTML (5 MB) and PDF manuals)
• The two figures in the brackets above indicate the respective sizes of the Windows/
Macintosh versions of the software.
• Approximately 229 MB (for Windows) / 109 MB (for Macintosh) of hard disk space on
your computer is required to install all the programs. Additional free hard disk space is
required to operate the programs.
3
Install the Software (Windows)
Continue on P. 6.
4
Install the Software (Macintosh)
English
1 Turn the computer on.
If the “...Would you like to look for the software
on the Internet?” appears, click [Cancel].
5
Unlock the Scanning Unit
• Unlock the Scanning Unit before connecting the scanner to the computer. If it is left
locked, a malfunction or other problem may occur.
3 Push the lock switch toward the unlock mark ( ). Lock Switch
Unlock Mark
4 Return the scanner to a horizontal position.
• When transporting the scanner, always lock the scanning unit by pushing the lock switch
toward the lock mark ( ).
• Carrying or transporting the scanner without locking the scanning unit may damage it.
Be particularly careful to lock the scanning unit when transporting the scanner in a
vehicle.
6
Connect the Scanner
English
• Confirm that the Scanning Unit is unlocked. (P.6)
Small Square
Connector
Wide Flat Connector
Macintosh
• Only use the USB interface cable provided with the scanner. Use of other cables may
lead to a malfunction.
• The scanner does not have a power switch. The power is activated as soon as the
computer is turned on.
7
Try Scanning
The following steps explain how to scan with ArcSoft PhotoStudio.
Top
Alignment Mark
Windows Macintosh
2 Select [Start], [Programs] or [All 2 Double-click the [Applications (Mac OS
Programs], [ArcSoft PhotoStudio] and 9)] folder and [PhotoStudio] folders and
[PhotoStudio 5]. the [PhotoStudio] icon.
8
Try Scanning
English
Windows Macintosh
4 Click the Acquire icon or click the 4 Click the Acquire icon or click the
[File] menu and select [Acquire]. [File] menu and select [Import...].
6 Click [Preview].
After calibration, the preview scan will start and gradually
display the image.
The image is automatically cropped in the original size.
If you want to trim the image further, drag the mouse diago-
nally to select the area.
9
Try Scanning
7 Click [Scan].
The final scan will start.
• If the scanner does not perform as described above, read the "Troubleshooting" section
of the Scanning Guide.
• For details about the bundled software, read the Scanning Guide or the User’s Guide
(PDF format manual) for each software program on the CanoScan Setup Utility CD-ROM.
10
Using the Scanner Buttons
English
You can use the three convenient buttons on the front of the scanner to scan and perform related tasks
easily with a single touch of the button. Place an item on the scanner before pressing a button
.
• To use these buttons, ScanGear CS, CanoScan Toolbox and ArcSoft PhotoBase should be
installed from the CanoScan Setup Utility CD-ROM.
• While scanning, you can change the default settings for scanning by clicking the
[Cancel] button. For changing settings or arranging the scanner button assignments,
refer to the CanoScan Toolbox section of Scanning Guide (HTML format manual).
11
Using the Scanner in the Upright Position
Installing the Stand
Positioning an Item
12
System Information
English
This form should be used to record the operating environment for the purchased scanner.
If any problems occur with the scanner, you will need this information when you contact our Customer
Support Help Desk. Be sure to record the information and store it in a safe location.
• This information is also required to request a repair under warranty. Make sure you record the
information and store it in a safe location.
• Guaranteed servicing for this equipment will expire five years after production ceases.
Date of Purchase:
Dealer Tel:
Dealer Address:
Scanner Model: CanoScan LiDE 20 LiDE 30
Serial Number (on the back of the equipment):
13
Specifications
CanoScan LiDE 20 CanoScan LiDE 30
Scanner Type Flatbed
Scanning Element CIS (Contact Image Sensor)
Light Source 3-color (RGB) LED
Optical Resolution 600 x 1200 dpi 1200 x 2400 dpi
Selectable Resolution 25 - 9600 dpi (ScanGear CS)
Color 16 bit input / 8 bit output for each color (RGB)
Scanning Bit Depth
Grayscale 16 bit input/8 bit output
16 msec/line (600 dpi)
Color 16 msec/line (600 dpi)
32 msec/line (1200 dpi)
5.3 msec/line (600 dpi)
Scanning Speed*1 Grayscale 5.3 msec/line (600 dpi)
10.6 msec/line (1200 dpi)
5.3 msec/line (600 dpi)
B&W 5.3 msec/line (600 dpi)
10.6 msec/line (1200 dpi)
Preview Speed*2 15 sec (approx.)
Interface USB 2.0 Full Speed (USB 1.1 equivalent)
Maximum Document Size A4/Letter: 216 x 297mm (8.5 x 11.7 in.)
Scanner Buttons 3 buttons: SCAN, COPY, E-MAIL
Temperature 5° to 35° C (41° to 95° F)
Operating Range
Humidity 10% to 90% RH (without condensation formation)
Power Requirements Supplied via USB port
Power Consumption In operation: 2.5 watts maximum Stand-by: 1.25 watts
Maximum Exterior Dimensions 256 x 383 x 34mm (10.1 x 15.1 x 1.3 in.)
Weight Approximately 1.5 kg (3.3 lbs.)
*1 Transfer time to computer is not included.
*2
Calibration processing time is not included.
• Before you upgrade to Windows XP from Windows 98/Me/2000, you must uninstall
ScanGear CS and CanoScan Toolbox using the “Uninstall the Software” menu of the
CanoScan Setup Utility CD-ROM. The scanner may not work if you upgrade to Windows
XP with these programs still installed. After upgrading to Windows XP, reinstall
ScanGear CS and CanoScan Toolbox according to the steps on page 4. For details, please
read the “Troubleshooting” section of the Scanning Guide (HTML format manual).
14