Type AL1: Accessories On Request: Secondary Terminal Cover Mounting Feet

This document provides specifications for two types of current transformers, the AL1 and AL2. It lists the available window sizes and secondary amperages for each type, along with the maximum volt-ampere ratings for different primary amperage classes. Dimensions are in millimeters. It is recommended to select the minimum required VA to avoid increased security factors and price for the current transformers.

Uploaded by

shan cool02
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views1 page

Type AL1: Accessories On Request: Secondary Terminal Cover Mounting Feet

This document provides specifications for two types of current transformers, the AL1 and AL2. It lists the available window sizes and secondary amperages for each type, along with the maximum volt-ampere ratings for different primary amperage classes. Dimensions are in millimeters. It is recommended to select the minimum required VA to avoid increased security factors and price for the current transformers.

Uploaded by

shan cool02
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Current Transformer

Window – Type MAG ELECTRIC Co.


0.72/ 3kV; 50 – 60 Hz

Type AL1

Secondary 1A,5A
Primary Class 0.5 Class 1 Class 3
Window Sizes A Max(VA) Max(VA) Max(VA)
50  5 5 7.5
Bars 75  10 10 12.5
30 × 10 or 100 5 5 7.5
150 10 10 12.5
20 × 10
200 10 12.5 15
250 12.5 15 17.5
Round conductors up to 23 ∅
300 15 17.5 20
400 15 17.5 22.5
Accessories on request:
500 15 17.5 27.5
Secondary terminal cover
600 15 17.5 27.5
Mounting feet
Other VA-Ratings, special ratios and CT’s class 0.2 on request

Dimensions in mm Only for cable conductors with primary 2 turns-for VA ≥ 1.25(CL0.5,1) VA ≥ 2.5 (CL 3)

Type AL2

Window Sizes

Bars Secondary 1A,5A


40 × 10 or Primary Class 0.5 Class 1 Class 3
30 × 10 A Max(VA) Max(VA) Max(VA)
200 5 7.5 10
Round conductors up to 25 ∅ 250 7.5 10 12.5
300 10 12.5 15
Accessories on request: 400 25 30 37.5
Secondary terminal cover 500 30 35 45
Mounting feet 600 30 35 50
800 35 40 50
Dimensions in mm Other VA-Ratings, special ratios and CT’s class 0.2 on request

! It is recommended to select the minimum required VA, otherwise the CTs security factor and price will increase.