Ba3240 PDF
Ba3240 PDF
User sM anual
ED-B3-MA-050530-001
BA3240
DEAR CUSTOMERS:
Please read the user manual carefully before using BA-3240,and operate according
to the user manual strictly.Any questions, please ask for the local distributor.
CONTENTS
1 Attentions P3
2 Functions&features P3
3 Parameters P4
4 Front panel P5
5 Back panel P5
6 Power supply P6
8 Operations P9
9 Protection functions P9
Do not open the cover because exist dangerous voltage,please ask the professional to repair
Do not expose it to the raining or moisture
Do not put it under the direct sunshine,high temperature or heat source
Keep good ventilation,not stop the ventilating hole
Note the local voltage must matched with the voltage required
Please put off the plug if not use for a long time
Connect with right load, not work under overload for a long time
Do not let the obstacle into the unit, keep the unit away the obstacles
Please stop using if the cable is damaged
Symbols:
The equilateral triangle with lightning bolt warns the user of dangerous voltage levels
localized within the cabinet.
The equilateral triangle with exclamatory mark means the important operation on the
user's manual.
2 FUNCTIONS&FEATURES
3
3 PARAMETERS
MODEL BA3240
Microphone >70dB
Line >80dB
TONE CONTROL
Mute >36 dB
4
4 FRONT PANEL
2 3 4 5 6 7
1 2 3
POWER -36 -30 -24 -18 -12 -6 0 (dB)
0 0
4 5 6
8 9 10 11 12 13
5 BACK PANEL
2 3 4 5 6 7 8
~110V/~220V
50-60Hz L L
CH1 CH2 · ÖCH3
Ê
ÇäøÈë CH4 CH5 CH6
INPUT 5 INPUT 4 INPUT 3 INPUT 2 INPUT 1
RMS 240W POWER OUTPUT ZONE POWER
INPUT STANDBY
R R
CHANNELS
COM 8 /1 W 4 25V 50V 70V 100V 120V 0V 24V/15A 24V PHANTOM 24V PHANTOM 24V PHANTOM 24V PHANTOM
MONITOR
MIC MIC MIC MIC
POWER
240VA LINE LINE LINE LINE
9 10 11 12 13 14 15 16 17
5
6 POWER SUPPLY
Please ensure that the back voltage showing is according with the local voltage
This unit have voltage selector, can be used for different voltage
Before operation, please chck the local voltage is optional for the 110/220V selector voltage,
you can connect it if correct and optional. If not optional, please put the selector to the correct
voltage value, please note cut off the power supply when select.
The operation as:
230V 115V
Be sure that the power input socket is good, power cable is not damaged when
connecting, Please power off when not using unit.
The normal working voltage is 250VA, the peak power cost about 600VA.
Note:
When selected to 220V, please use 2.5A 5*20mm delay style fuse
When selected to 110V, please use 5A 5*20mm delay style fuse
Please use the correct fuse when voltage power changed
Note that the voltage will be put to 220 when leaving factory
6
7 FUNCTION SETUP AND CABLE CONNECTION
Zone1 Zone 6
~110V/~220V
50-60Hz L L
CH1 CH2 · ÖCH3
Ê
ÇäøÈë CH4 CH5 CH6
INPUT 5 INPUT 4 INPUT 3 INPUT 2 INPUT 1
RMS 240W POWER OUTPUT ZONE POWER
INPUT STANDBY
R R
CHANNELS
COM 8 /1 W 4 25V 50V 70V 100V 120V 0V 24V/15A 24V PHANTOM 24V PHANTOM 24V PHANTOM 24V PHANTOM
MONITOR
MIC MIC MIC MIC
POWER
240VA LINE LINE LINE LINE
Insert equipment
SIGNAL 2 1
3 INPUT1-INPUT4 is unbalanced input, as left connecting
SIGNAL
SIGNAL GROUND
SIGNAL 2 1
3
SIGNAL
INPUT1-INPUT4 is balanced connecting, as left connecting
SIGNAL GROUND
Note:
Channel input1 is priority channel, should be inserted urgency microphone or
fire fighting signal.
7
7 FUNCTION SETUP AND CABLE CONNECTION
A B C
A indicates that the channel is set to 24V phantasm microphone input, the input
sensitivity is 10mV
B indicates that the channel is set to microphone input, the input sensitivity is 10mV
C indicates that the channel is set to line input, the input sensitivity is 200mV
8
8 OPERATIONS
1 Start
a set the right function and connect the right cable
b check the output line and see if it is short circuit or loading is too low
c check the local voltage is same as the require of power
d adjust the volume to Min
e connect the power supply,then open the sound source,pre and effect equipments,
must sure all equipments work well
f Open the power supply,and sure the indicator is lit up
g Adjust the volume to right place clockwise
2 Put off
a adjust volume to Min. counter-clockwise
b put off the power supply,and sure the indicator off
c put off the pre and effect equipments and sound source equipment
3 Volume adjust
Connect the input signal and open the sound source,adjust the volume,if the indicator
is not lit up,please check the sound source.Adjust according to the voltage output and
the signal.When 0dB output voltage is lit up,the output is RMS, if is too much,will cause
the distortion
4 Area setting
Six buttons and six yellow indicators, when the six indicators are lit up, it means that
there are output in six areas,press the area button, the relative area will be closed and
the indicators will be off
9 PROTECTION FUNCTIONS
BA-3240 Completed functions give the amplifier and speaker a good protection to avoid
the damage, like short circuit,overloading,and overheat.
1 Circuit protect: when exist the short circuit,it will be off automatically
2 Cverload protect: it will be off automatically when input impedance is too low
9
10 TROUBLES AND TROUBLE SHOOTINGS
Status Solutions
If it does not work according to the above steps,please ask for the professional to repair.
10
R
User sM anual
BA3240