0% found this document useful (0 votes)
202 views1 page

Autotech: Terminal Board Wiring

1) The document provides instructions for the AUTOTECH TERMINAL BOARD WIRING MODEL S-5050, which is suitable for automatic sliding gates and rolling shutters. 2) It describes the board's ability to automatically detect motor travel limits using terminal switches, and to automatically stop the motor if a sudden change in current is detected. 3) The board can be programmed to accept up to 15 remote controls by learning the codes when their buttons are pressed during the auto-learn process.

Uploaded by

vfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
202 views1 page

Autotech: Terminal Board Wiring

1) The document provides instructions for the AUTOTECH TERMINAL BOARD WIRING MODEL S-5050, which is suitable for automatic sliding gates and rolling shutters. 2) It describes the board's ability to automatically detect motor travel limits using terminal switches, and to automatically stop the motor if a sudden change in current is detected. 3) The board can be programmed to accept up to 15 remote controls by learning the codes when their buttons are pressed during the auto-learn process.

Uploaded by

vfan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

AUTOTECH TERMINAL BOARD WIRING MODEL S-5050

Suitable for automatic sliding gates & for Rolling shutters


AUTOMATIC DETECTION OF MOTOR TRAVEL LIMITS (TERMINAL SWITCHES)
The board can recognize automatically the mechanical travel switches of the motor. When any travel switch switches
off then the operating time is reset and the board is ready for the next command.

AUTOMATIC POWER STOP: The control board is constantly measuring the motor operation
current and if a sudden change is detected the motor stops.
Transmitters Code Memorizing AUTO-LEARN
The board can be programmed to accept up to 15 remote controls with different code or channel.
In order to program the board to accept a remote control we press once the button "AUTO LEARN" on the
board. Then the LED L5 is turned ON for about 10''.
As long as it is lit, we can s tore any remote control in the board memory by pressing the button of the remote
control. If the board accepts the remote control then the LED turns off and the motor starts.
If we don't press any remote control, after 10'' the LED turns off and the board comes out of the AUTO LEARN
function.
When we want to store more than 4 codes, then automatically the oldest code will be cancelled and replaced
by the new one.
Erase All Programmed Codes
To erase all programmed memory remote controls from the board then we press the button continuously (about
10'') until the LED is flashing, Then we release the button. All the programmed codes have been erased.. .

AUTO CLOSE FUNCTION LED FUNCTIONS L5 LAMP FUNCTION


ODS FUNCTION
Adjust the automating closing time Obstacle detection System LEDL5 apart from the use of ON
Lighting operation
(in seconds), after which the gate closes memorizing the transmitters codes, 1 2 3 4 The light is on continuously as long as the motor is operating
also functions the ODS. & turns off 1 minute after the motor stops.
60 automatically. LOW-SENSITIVE When the LED is not lit while the ON

HI-SENSITIVE motor is in operation, then the Flashing operation


1 2 3 4
ODS Obstactle Detection System is not in The light is flashing as long as the motor is operating
120 The automating OUT OF USE use. & turns off when the motor stops.
3 closing time is off. When the LED is flashing while the
START BUTTON FUNCTIONS
motor is in operation then the ODS
ON
is in use. OPEN STOP CLOSE STOP OPEN ....
1 2 3 4
ON

Power indicator L6 1 2 3 4
OPEN STOP CLOSE OPEN ....

PHOTO-CELL FUNCTIONS
L6 In order to connect photo-cells the board has an auxiliary output ( 24Volt / 200mA
ON

1 2 3 4 The motor stops in case of obstactle detection.


ON

1 2 3 4
The motor stops & opens in case of obstactle detection.

ODS Obstacle Detection


ΛΕΙΤΟΥΡΓΙΑ System FUNCTIONS
ΥΠΕΡΦΟΡΤΩΣΗΣ ΜΟΤΕΡ (POWER STOP)
ON

L5 1 2 3 4
The motor stops in case of obstactle detection.
ON

1 2 3 4 The motor stops & opens in case of obstactle detection.

L1 L2 L3 L4
Indication of LED Function
Terminal OPEN LIMIT switch
L1 Light ON -->terminal switch contact is closed
Light OFF -->terminal switch contact is opened

Terminal CLOSE LIMIT switch


L2 Light ON -->terminal switch contact is closed
open

Light OFF -->terminal switch contact is opened


common

close

START button LED


LAMP L3 Light ON --> button is pressed (closed)
230VAC 220V
Light OFF --> button is not pressed (open)
OPEN LIMIT Photo Cell
switch contact
Photo Cell LED
MOTOR 230VAC

L4 Light ON --> photo-cell contact is closed


! The first operation command of the motor CLOSE LIMIT START BUTTON Light OFF --> photo-cell contact is opened
after the power interruption is "OPEN" switch switch (N.O.)

Exclusively skilled technical personnel must install the control unit in compiliance with the regulations concerning the field of automatic opening devices, blinds,
rolling shutters. Unqualified personnel or those who do not know the standards applicable to the “Automatic gates and doors” category must under no
circumstances carry out installations and systems.
ANTENNA As Antenna serves an insulated wire, which has been specially selected for this purpose. Please, position it as far away from metallic objects as possible. Do not
shorten, lengthen, or otherwise modify the wire. Connect a 17 cm piece of rigid wire to the antenna pole binding post. For best results use a tuned antenna connected to the
receiver using RG 58 (impedance 50 Ohm) coaxial cable with a maximum length of 15 meters.
Exclusively skilled technical personnel according to the rules concerning the field of automatic opening devices, blinds, rolling shutters, must install the control unit.
Unqualified personnel or those who do not know the standards applicable to the “Automatic gates and doors” category must under no circumstances carry out installations

You might also like