GameChange Solar Genius Tracker 2P Technical Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OVER 10 GW SOLD

Global Leader for Fixed Tilt Structures & Trackers

TECHNICAL DATASHEET

GENIUS TRACKER 2P ™

WORLD'S HIGHEST POWER PRODUCING


& FASTEST INSTALLING 2P SOLAR TRACKER

PRE-ASSEMBLED DRIVE SYSTEM


ACTUATOR
Rugged design for 40-year field life
in harsh environmental climate:
50% FASTER
than typical competitor drive systems.
No machines or driveline for industry’s
IP66 rated
fastest install.

SADDLE BRACKET
Allows efficient alignment CONTROLLER
with row tube 24V battery charged by small solar module drives
24V actuator motor, ZigBee wireless communication

DRIVE POST SELF-LUBRICATING DRIVE BEARING


Wide Flange Self lubricating open form polymer bearing
that improves damping

OWNER BENEFITS

1.25 % MORE POWER PRODUCTION


UP
TO

RESULTS IN HIGHER KWH OUTPUT AND HIGHER ROE


based on project specifics

INSTALLER BENEFITS

· FEWER POST COUNT PER MW UP TO 55% LESS POSTS THAN SOME 1P COMPETITORS
· SHORTER 200 FT [61 M] TRACKERS INSTALL EASILY ON UNDULATING
SITES TO REDUCE GRADING

· FASTEST INSTALLING DRIVE SYSTEM UTILIZING PRE-ASSEMBLED COMPONENTS


OVER 10 GW SOLD
Global Leader for Fixed Tilt Structures & Trackers

Modules Modules Supported Most commercially available modules, including frameless

OWNER BENEFITS Civil Slope Tolerance (N-S)


crystalline and thin film
7% standard, can go to 10% special order
UP TO 1.25% MORE POWER Slope Tolerance (E-W) 15%
PRODUCTION AND HIGHER ROE Tracker follows slope (Y/N) Yes
Combine to increase owner cash flow Structural Drive Type Robust linear actuator stainless steel & aluminum
Posts per MW 170/MW for normal wind conditions
WEATHERSMART™
Proprietary algorithm optimizes tilt
Design Wind Load 105 mph [46.9 m/s](Std) / 115 mph [51.4 m/s](Premium 1) /
angle based on weather data to 130 mph [58.12 m/s](Premium 2)
maximize power production, adds up Snow Load 5 psf [.24 kPa](Std) / 20 psf [.96 kPa](Premium 1) / 40 psf [1.92 kPa](Premium 2) /
to 1.25% additional power production 60 psf [2.87 kPa](Premium 3)
Tracking Range (Std) 45°, 52°
LOWEST O&M COST
Lowest grass cutting & module Tracking Range (Premium) 60°
washing cost Post Sections HDG wide flange steel
Post Size (Interior) & (Exterior) W6 or W8 Wide Flange
Zero maintenance drive system Motor Foundation W6 or W8 Wide Flange
Standard Embedment 5 - 9 ft. [1.52 - 2.75 m]
INSTALLER BENEFITS Design
Flood Plain Allowance
Module Configuration
Up to 6 ft. [1.83 m]
2 up in portrait for crystalline & First Solar Series 6™,
FASTEST INSTALLING SYSTEM 2 up in portrait for Bifacial, 6 to 8 up landscape for First Solar Series 4™
Advanced design innovations Length per Table Up to 205 ft. [62.48 m] (for example 120 crystaline modules)
& pre-assembled components Module Attachment Bottom mount for framed modules
PRE-ASSEMBLED DRIVE ARM
or clamps for glass on glass modules
Can be lifted by one worker, no Ground Coverage Ratio 0.3 to 0.65
machine required. 50% faster than Rows per Drive 1 drive per tracker(table), distributed drive system
typical competitors Powering System Onboard solar module with battery
Ground Clearance To Module 18 - 48 in. [45.7 - 121.9 cm] typical
PE STAMPED DRAWINGS
Design loads according to local Min / Max Ground to Top of Post 70 in. [1.78 m] typical + 9 in. [22.86 cm] min. adjustment range
building codes: ASCE 7, NBC, Backtracking / Anti-shading Yes, although can be turned off as requested (i.e. for FSLR modules)
Eurocode, AS1170, GB 50009 Temperature Range -20° C (-40° C also available) + 48° C
Electromagnetic Interference Compliant with FCC guidelines/ Applicable sections EN 61000
PROPRIETARY INTEGRATED HARDWARE™
For faster structure assembly, module
Install Specialty Tools Required No
mounting and reduced O&M cost. Max Offload for Deliveries As per customer requirement
Oversized Serrated Flange Nyloc Nut Electrical Tracking Method Time and location based algorithm
and Oversized Flange Star Bolt with String Design Compatible with any string size
integrated star washer eliminates
Cable Supports Hole punching as per customer requirement for nominal cost
the need for washers and star washers
Linear Actuator Motor 24V DC UL Listed
Parasitic Loss 0 amps
Controller Box ZigBee® wireless communications, 24V solar module and battery
Control System Master to Node: ZigBee® wireless communications
Master to SCADA/DAS: Modbus TCP communications
# of Motors 25/MW for typical conditions, depending on module wattage and loading
1000V System or 1500V System Both
Grounding Method Tracker structure is part of grounding path per UL 2703
GameChange Solar UL Compliance UL 2703 / UL 3703
HEADQUARTERS Ingress Protection IP66 (NEMA 4/4x equivalent)
152 W 57th Street 44th Fl. # Weather Station 1 per 6 MW - 10 MW typical
New York, NY 10019, USA Monitoring System Web portal interface available
Phone: +1 (212) 388-5160 Compatible with all standard third party monitoring vendors
Fax: +1 (646) 607-2223 Snow & Flood Sensors Move modules to optimum location for weather events
[email protected]
Backup Power Solar module and battery providing integrated backup - 3 days
gamechangesolar.com
O&M Warranty 5 year drive & control, 10 year structural standard, 10 /20 also available
EUROPE OFFICES ASIA OFFICES Shipping Max load International - 18.5 to 22.5 metric tons per container
Dublin, Ireland Wuxi, China USA - 45,000 lbs. [20,411 kg] per truckload, 5,000 lbs. [2,267 kg] maximum
Zug, Switzerland Mumbai, India
Madrid, Spain bundle size, 2,900 lbs. [1315.4 kg] or other maximum as requested by customers
Shipping Containers or Flatbeds Flat beds for structure, dry vans for hardware
# Trucks or Containers per MWdc 4 typical for trucks, 5 typical for containers
DISCLAIMER: GameChange Solar
provides this documentation without
Commissioning Backfeed required? No, Generator for power as alternative
warranty in any form either expressed or
implied. GameChange Solar may revise this
document at any time without notice. Rev. 8-12-2020

You might also like