Pressure Transmitter For General Industrial Purposes: MBS 3000 and MBS 3050
Pressure Transmitter For General Industrial Purposes: MBS 3000 and MBS 3050
Pressure Transmitter For General Industrial Purposes: MBS 3000 and MBS 3050
Features • Designed for use in severe industrial • All standard output signals:
and hydraulic environments 4 – 20 mA, 0 – 5 V, 1 – 5 V, 1 – 6 V, 0 – 10 V,
• Resistant to cavitation, liquid hammer 1 – 10 V, Ratiometric output signal: 10-90% of
and pressure peaks (MBS 3050) supply voltage
• Enslosure and wetted parts of acid-resistant • A wide range of pressure and electrical
stainless steel (AISI 316L) connections
• Pressure ranges in relative (gauge) • Fully digitally compensated
or absolute from 0 up to 600 bar • For use in ATEX zone 2 explosive atmospheres
Electrical specifications
Nom. output signal 0 – 5, 1 – 5, 0 – 10 V, Ratiometric
4 – 20 mA
(short-circuit protected) 1– 6 V 1 – 10 V 10 – 90% of [UB]
Supply voltage [UB], polarity protected 9 – 32 V DC 9 – 32 V DC 15 – 32 V DC 4.5 – 5.5 V DC
Supply – current consumption – ≤ 5 mA ≤ 8 mA ≤ 5 mA at 5 V DC
Supply voltage dependency < 0.1% FS / 10 V < 0.05% FS / 10 V --
Ratiometricity - - < 0.05% FS / 4.5 - 5.5 V
0-5V: 5.75 V
Output limitation 22.4 mA 1-5V: 5.6 V 0-10V: 11.5 V ≈ supply voltage
1-6V: 6.75 V
Sink / Source – < 1 mA
Load [RL] (load connected to 0 V) RL ≤ (UB- 9V) / 0.02 A RL ≥ 10 kΩ RL ≥ 15 kΩ RL ≥ 10 kΩ at 5 V DC
Explosive atmospheres
When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.
Mechanical characteristics
Wetted parts EN 10088-1; 1.4404 (AISI 316 L)
Materials Enclosure EN 10088-1; 1.4404 (AISI 316 L)
Electrical connections See page 6 & 7
Net weight (depending on pressure connection and electrical connection) 0.2 – 0.3 kg
Pressure connection
AB04 G ¼ A (EN 837) (MBS 3000 only)
AB06 G 3⁄8 A (EN 837) (MBS 3000 only)
Standard 00 AB08 G ½ A (EN 837)
With pulse-snubber 50 AC04 ¼ – 18 NPT
AC08 ½ – 14 NPT (MBS 3000 only)
Measuring range GB04 DIN 3852-E-G ¼,
0 – 1 bar 10 FA09 DIN 3852-E-M14 x 1.5
0 – 1.6 bar 12 FA12 DIN 3852/3, M18 x 1.5-6g
9
0 – 2.5 bar 14 FD10 /16 – 18 UBF - 2A (SAEJ514)
0 – 4 bar 16
0 – 6 bar 18
0 – 10 bar 20
0 – 16 bar 22 Electrical connection
0 – 25 bar 24 Figures refer to plug
0 – 40 bar 26 and standard PIN configuration – see page 6 & 7
0 – 60 bar 28 A1 Plug Pg 9 (EN 175301-803-A)
0 – 100 bar 30 A6 Plug, Pg 11 (EN 175301-803-A)
0 – 160 bar 32 A3 Screened cable, 2 m
0 – 250 bar 34 E3 * Plug, EN 60947-5-2, M12 × 1; 4-pin; male, excl. female plug
0 – 400 bar 36 A8 * Plug, AMP Superseal 1.5 series male, excl. female plug
0 – 600 bar 38 C8 Bayonet plug, ISO 15170-A1-3.2 Sn (Ratiometric output only)
D9 * Plug, AMP 173065, male flying leads 125 mm excl. female plug
G1 * Plug, AMP Econoseal, J series, male excl. female plug
Preferred versions
34 38
39.5
39.5
Dimensions/Combinations
Type code AB04 AB06 AB08 AC04 AC08 GB04 FA09 FA12 FD10
2 – 3 turns 2 – 3 turns
Recommended
30 – 35 Nm 30 – 35 Nm 30 – 35 Nm after finger after finger 30 – 35 Nm 30 – 35 Nm 30 – 35 Nm 30 – 35 Nm
torque 1)
tightened tightened
1
) Depends on different parameters such as gasket material, mating material, thread lubrication and pressure level
AI244586497020en-001001 | 5
Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050
Electrical connections
Enclosure
(IP protection fulfilled
IP65 IP67 IP67 IP67
together with mating
connector)
Type code C8 D9 G1
Enclosure
(IP protection fulfilled
IP67 IP67 IP67
together with mating
connector)
Pin 1: + supply
Electrical connection Pin 1: + supply
Pin 2: ÷ supply/common
Ratiometric Pin 2: ÷ supply/common
Pin 3: + output -
output, 10-90% Pin 3: + output
Pin 4: Not used
of supply voltage