Data sheet

Pressure transmitter for general industrial purposes


MBS 3000 and MBS 3050

The compact pressure transmitter,


type MBS 3000, is designed for use in industrial
and hydraulic applications, and offers a reliable
pressure measurement, even under harsh
environmental conditions.
The compact heavy duty pressure transmitter
MBS 3050 with integrated pulse-snubber is
designed for use in hydraulic applications with
severe medium influences like cavitation, liquid
hammer or pressure peaks and offers a reliable
pressure measurement, even under harsh
environmental conditions.
The flexible pressure transmitter programme
covers different output signals, absolute or
gauge (relative) versions, measuring ranges
from 0 – 1 to 0 – 600 bar. A wide range of pressure
and electrical connections are available.
Excellent vibration stability, robust construction,
and a high degree of EMC/EMI protection equip
the pressure transmitter to meet the most
stringent industrial requirements.

Features • Designed for use in severe industrial • All standard output signals:
and hydraulic environments 4 – 20 mA, 0 – 5 V, 1 – 5 V, 1 – 6 V, 0 – 10 V,
• Resistant to cavitation, liquid hammer 1 – 10 V, Ratiometric output signal: 10-90% of
and pressure peaks (MBS 3050) supply voltage
• Enslosure and wetted parts of acid-resistant • A wide range of pressure and electrical
stainless steel (AISI 316L) connections
• Pressure ranges in relative (gauge) • Fully digitally compensated
or absolute from 0 up to 600 bar • For use in ATEX zone 2 explosive atmospheres

© Danfoss | DCS (im) | 2020.04 AI244586497020en-001001 | 1


Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050

Application and media Application Media condition


conditions for MBS 3050 Cavitation, liquid hammer and pressure peaks Clogging of the nozzle may occur in liquids
may occur in hydraulic systems with changes in containing particles. Mounting the transmitter in
flow velocity, e.g. fast closing of a valve or when a an upright position minimizes the risk of clogging,
pump starts and stops. because the flow in the nozzle is limited to the
The problem may occur on the inlet and outlet start-up period until the dead volume behind the
side of the application, even at rather low nozzle orifice is filled. The media viscosity has only
operating pressures. little effect on the response time. Even at a viscosities
up to 100 cSt, the response time will not exceed 4 ms.
Pulse-snubber

Technical data Performance (EN 60770)


≤ ± 0.5% FS (typ.)
Accuracy (incl. non-linearity, hysteresis and repeatability)
≤ ± 1% FS (max.)
Non-linearity BFSL (conformity) ≤ ± 0.2% FS
Hysteresis and repeatability ≤ ± 0.1% FS
≤ ± 0.1% FS / 10K (typ.)
Thermal zero point shift
≤ ± 0.2% FS / 10K (max.)
≤ ± 0.1% FS / 10K (typ.)
Thermal sensitivity (span) shift
≤ ± 0.2% FS / 10K (max.)
Liquids with viscosity < 100 cSt < 4 ms
Response time
Air and gases (MBS 3050) < 35 ms
Overload pressure (static) 6 × FS (max. 1500 bar)
Burst pressure 6 × FS (max. 2000 bar)
Power-up time < 50 ms
Durability, P: 10 – 90% FS >10 × 106 cycles

Electrical specifications
Nom. output signal 0 – 5, 1 – 5, 0 – 10 V, Ratiometric
4 – 20 mA
(short-circuit protected) 1– 6 V 1 – 10 V 10 – 90% of [UB]
Supply voltage [UB], polarity protected 9 – 32 V DC 9 – 32 V DC 15 – 32 V DC 4.5 – 5.5 V DC
Supply – current consumption – ≤ 5 mA ≤ 8 mA ≤ 5 mA at 5 V DC
Supply voltage dependency < 0.1% FS / 10 V < 0.05% FS / 10 V --
Ratiometricity - - < 0.05% FS / 4.5 - 5.5 V
0-5V: 5.75 V
Output limitation 22.4 mA 1-5V: 5.6 V 0-10V: 11.5 V ≈ supply voltage
1-6V: 6.75 V
Sink / Source – < 1 mA
Load [RL] (load connected to 0 V) RL ≤ (UB- 9V) / 0.02 A RL ≥ 10 kΩ RL ≥ 15 kΩ RL ≥ 10 kΩ at 5 V DC

2 | AI244586497020en-001001 © Danfoss | DCS (im) | 2020.04


Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050

Technical data Environmental conditions


(continued)
Normal -40 – 85 °C
Sensor operating temperature
ATEX Zone 2 -10 – 85 °C
Media temperature range -40 – 85 °C
Ambient temperature range (depending on electrical connection) See page 6
Compensated temperature range 0 – 80 °C
Transport/storage temperature range -50 – 85 °C
EMC – Emission EN 61000-6-3
EMC – Immunity EN 61000-6-2
Insulation resistance > 100 MΩ at 500 V DC
Mains frequency test Based on SEN 361503
15.9 mm-pp, 5 Hz – 25 Hz
Sinusoidal IEC 60068-2-6
Vibration stability 20 g, 25 Hz – 2 kHz
Random 7.5 grms , 5 Hz – 1 kHz IEC 60068-2-64
Shock 500 g / 1 ms IEC 60068-2-27
Shock resistance
Free fall 1m IEC 60068-2-32
Enclosure (depending on electrical connection) See page 6 & 7

Explosive atmospheres

Zone 2 applications EN60079-0; EN60079-15; EN60079-7


-10 ˚C < Ta < + 85 ˚C

When used in ATEX Zone 2 areas at low temperatures the cable and plug must be protected against impact.

Mechanical characteristics
Wetted parts EN 10088-1; 1.4404 (AISI 316 L)
Materials Enclosure EN 10088-1; 1.4404 (AISI 316 L)
Electrical connections See page 6 & 7
Net weight (depending on pressure connection and electrical connection) 0.2 – 0.3 kg

© Danfoss | DCS (im) | 2020.04 AI244586497020en-001001 | 3


Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050

Ordering standard MBS 30.. – – –

Gasket / O-ring material


0 No gasket
2 Gasket, NBR -40 – 85 °C
4 O-ring, NBR -40 – 85 °C

Pressure connection
AB04 G ¼ A (EN 837) (MBS 3000 only)
AB06 G 3⁄8 A (EN 837) (MBS 3000 only)
Standard 00 AB08 G ½ A (EN 837)
With pulse-snubber 50 AC04 ¼ – 18 NPT
AC08 ½ – 14 NPT (MBS 3000 only)
Measuring range GB04 DIN 3852-E-G ¼,
0 – 1 bar 10 FA09 DIN 3852-E-M14 x 1.5
0 – 1.6 bar 12 FA12 DIN 3852/3, M18 x 1.5-6g
9
0 – 2.5 bar 14 FD10 /16 – 18 UBF - 2A (SAEJ514)
0 – 4 bar 16
0 – 6 bar 18
0 – 10 bar 20
0 – 16 bar 22 Electrical connection
0 – 25 bar 24 Figures refer to plug
0 – 40 bar 26 and standard PIN configuration – see page 6 & 7
0 – 60 bar 28 A1 Plug Pg 9 (EN 175301-803-A)
0 – 100 bar 30 A6 Plug, Pg 11 (EN 175301-803-A)
0 – 160 bar 32 A3 Screened cable, 2 m
0 – 250 bar 34 E3 * Plug, EN 60947-5-2, M12 × 1; 4-pin; male, excl. female plug
0 – 400 bar 36 A8 * Plug, AMP Superseal 1.5 series male, excl. female plug
0 – 600 bar 38 C8 Bayonet plug, ISO 15170-A1-3.2 Sn (Ratiometric output only)
D9 * Plug, AMP 173065, male flying leads 125 mm excl. female plug
G1 * Plug, AMP Econoseal, J series, male excl. female plug

Pressure reference Output signal


Gauge (relative) 1 1 4 – 20 mA
Non-standard build-up Absolute 2 2 0–5V
combinations may be selected.
3 1–5V
However, minimum order
4 1–6V
quantities may apply. * Gauge versions only available as
5 0 – 10 V
Please contact your sealed gauge versions
7 1 – 10 V
local Danfoss office
for further information. 6 Ratiometric, 10 – 90%

Preferred versions

4 | AI244586497020en-001001 © Danfoss | DCS (im) | 2020.04


Type
A1 A3 E3 A8 A6 C8 D9 G1
code
EN175301-803-A, 2 m screened EN 60947-5-2 EN 175301-803-A ISO 15170-A1- AMP 173065, male,
AMP Superseal AMP Econoseal
Pg 9 cable M12 × 1; 4-pin Pg 11 3.2-SN Flying leads

34 38

39.5
39.5
Dimensions/Combinations

© Danfoss | DCS (im) | 2020.04


Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050

DIN 3852-E-M14 DIN 3852/3, 9


G¼A G 3/8 A G½A DIN 3852-E-G ¼ /16– 18 UNF-2A
¼ – 18 NPT ½ – 14 NPT x 1.5 M 18 × 1.5 – 6 g
(EN 837) (EN 837) (EN 837) R (SAE J514)

Type code AB04 AB06 AB08 AC04 AC08 GB04 FA09 FA12 FD10

2 – 3 turns 2 – 3 turns
Recommended
30 – 35 Nm 30 – 35 Nm 30 – 35 Nm after finger after finger 30 – 35 Nm 30 – 35 Nm 30 – 35 Nm 30 – 35 Nm
torque 1)
tightened tightened

1
) Depends on different parameters such as gasket material, mating material, thread lubrication and pressure level

AI244586497020en-001001 | 5
Data sheet | Pressure transmitter for general industrial purposes, MBS 3000 and MBS 3050

Electrical connections

Type code A1 & A6 A3 E3 A8

EN 175301-803-A, EN 60947-5-2 AMP Superseal


Pg 9 & Pg 11 2 m screened cable M12 × 1; 4-pin 1.5 series (male)

Ambient temperature -40 – 85 °C -30 – 85 °C -25 – 90 °C - 30 – 85 °C

Enclosure
(IP protection fulfilled
IP65 IP67 IP67 IP67
together with mating
connector)

Glass filled Poliolyfin cable with Nickel plated Glass filled


Material
polyamid, PA 6.6 1) PE shrinkage tubing brass, CuZn/Ni polyamid, PA 6.6 2)

Pin1: + supply Brown wire: + supply Pin 1: + supply Pin 1: + supply


Pin 2: ÷ supply Black wire: ÷ supply Pin 2: not used Pin 2: ÷ supply
Pin 3: not used Red wire: not used Pin 3: not used Pin 3: not used
Electrical connection, Orange: not used Pin 4: ÷ supply
4 – 20 mA output Screen: not connected
(2 wire) to MBS enclosure
Earth: Connected
to MBS enclosure
Pin 1: + supply Brown wire: + output Pin 1: + supply Pin 1: + supply
Pin 2: ÷ supply/common Black wire: ÷ supply Pin 2: not used Pin 2: ÷ supply/common
Pin 3: + output Red wire: + supply Pin 3: + output Pin 3: + output
Electrical connection, Orange: not used Pin 4: ÷ supply/common
0 – 5 V, 1 – 5 V, 1 – 6 V, Screen: not connected
0 – 10 V, 1 – 10 V output to MBS enclosure
Earth: Connected
to MBS enclosure
Pin 1: + supply Brown wire: output Pin 1: + supply Pin 1: + supply
Pin 2: ÷ supply Black wire: Pin 2: Not used Pin 2: ÷ supply
Electrical Pin 3: output/common ÷ supply Pin 3: output Pin 3: output/Common
connection Red wire: Pin 4: ÷ supply/Common
Ratiometric Common3)
output, 10-90% Orange: Not used
of supply voltage Earth: Connected Screen: Not connected
to MBS enclosure to MBS enclosure
1
) Female plug: Glass filled polyester, PBT
2
) Wire: PTFE (teflon) Protection sleeve: PBT mesh (polyester)
3)
Common

6 | AI244586497020en-001001 © Danfoss | DCS (im) | 2020.04


Electrical connections
continued

Type code C8 D9 G1

ISO 15170-A1-3.2-Sn AMP 173065, male AMP Econoseal


Bayonet Flying leads 125 mm J series (male)

Ambient temperature -40 – 85 °C -40 – 85 °C -30 – 85 °C

Enclosure
(IP protection fulfilled
IP67 IP67 IP67
together with mating
connector)

Glass filled Glass filled Glass filled


Material
polyester PBT 2) polyester, PBT 2) polyamide, PA 6.61)

Electrical connection, Pin 1: + supply Pin 1: + supply


4 – 20 mA output - Pin 2: - supply Pin 2: ÷ supply/common
(2 wire) Pin 3: not used Pin 3: not used

Electrical connection, Pin 1: + supply Pin 1: + supply


0 – 5 V, 1 – 5 V, 1 – 6 V, - Pin 2: - supply Pin 2: ÷ supply/Common
0 – 10 V, 1 – 10 V output Pin 3: + output Pin 3: + output

Pin 1: + supply
Electrical connection Pin 1: + supply
Pin 2: ÷ supply/common
Ratiometric Pin 2: ÷ supply/common
Pin 3: + output -
output, 10-90% Pin 3: + output
Pin 4: Not used
of supply voltage

) Female plug: Glass filled polyester, PBT


1

) Wire: PTFE (teflon) Protection sleeve: PBT mesh (polyester)


2

© Danfoss | DCS (im) | 2020.04 AI244586497020en-001001 | 7