IO-Device PROFINET Functions TIAPortal en

The document lists various PROFINET modules and their support for different functions: - Many modules support IRT, prioritized startup, MRP, MRPD, and PROFIenergy from certain firmware versions onwards. Supported functions vary between module types. - Address space per station ranges from 1 byte to 1430 bytes depending on the module and configuration such as use of system redundancy. - Maximum record length is generally 240 bytes for acyclic communication. - Send clock for IRT and RT communication ranges from 125 microseconds to 1 millisecond depending on the module. - Functions like shared device, MSI/MSO, I device, isochronous mode, and system redundancy are

Uploaded by

Stefan Đordan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views8 pages

IO-Device PROFINET Functions TIAPortal en

The document lists various PROFINET modules and their support for different functions: - Many modules support IRT, prioritized startup, MRP, MRPD, and PROFIenergy from certain firmware versions onwards. Supported functions vary between module types. - Address space per station ranges from 1 byte to 1430 bytes depending on the module and configuration such as use of system redundancy. - Maximum record length is generally 240 bytes for acyclic communication. - Send clock for IRT and RT communication ranges from 125 microseconds to 1 millisecond depending on the module. - Functions like shared device, MSI/MSO, I device, isochronous mode, and system redundancy are

Uploaded by

Stefan Đordan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 8

Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,

s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

Module Link to Product information / IRT Min. PROFINET Address area per station Max. record prioritized MRP MRPD PROFIenergy Shared device
Order number send clock length (acyclic) startup
(RT and IRT)
ET 200SP
IM 155-6 PN BA 6ES7155-6AR00-0AN0 − 1 ms 32 Byte 240 Byte − from V3.2 − − −
IM 155-6 PN ST 6ES7155-6AU00-0BN0 from V1.0 250 µs 512 Byte 240 Byte from V1.0 from V1.0 − from V1.0 from V1.03)
6ES7155-6AU01-0BN0 from V4.1 250 µs 512 Byte 240 Byte from V4.1 from V4.1 − from V4.1 from V4.13)
IM 155-6 PN HF 6ES7155-6AU00-0CN0 from V2.0 250 µs 933 Byte (without system redundancy)7) 240 Byte from V2.0 from V2.0 − from V2.0 from V2.02)
493 Byte (with system redundancy)7)
IM 155-6 PN/2 HF 6ES7155-6AU01-0CN0 from V4.2 250 µs 933 Byte (without system redundancy)7) 240 Byte from V4.2 from V4.2 − from V4.2 from V4.22)
493 Byte (with system redundancy)7)
IM 155-6 PN/3 HF 6ES7155-6AU30-0CN0 from V4.2 250 µs 933 Byte (without system redundancy)7) 240 Byte from V4.2 from V4.2 − from V4.2 from V4.22)
493 Byte (with system redundancy)7)
IM 155-6 PN HS 6ES7155-6AU00-0DN0 from V4.0 125 µs 968 Byte 240 Byte from V4.0 from V4.0 from V4.0 from V4.0 from V4.0
IM 155-6 PN HA 6DL1155-6AU00-0PM0 − 1 ms • max. 1440 Byte in sum: without system 240 Byte − from V1.0 − − from V1.1
redundancy, 1 or 2 Controller
• max. 360 Byte each Controller: without
system redundancy, 3 or 4 Controller
• max. 1000 Byte (with system redundancy, 1
redundante Controller)
• max. 360 Byte each Controller (with system
redundancy, 1 redundante Controller and 1
other Controller)
• max. 1440 Byte (R1 System redundancy)

ET 200MP
IM 155-5 PN BA 6ES7155-5AA00-0AA0 − 1 ms 64 Byte 240 Byte − from V4.0 − − from V4.03)
IM 155-5 PN ST 6ES7155-5AA00-0AB0 from V1.0 250 µs 512 Byte 240 Byte from V1.0 from V1.0 − − from V1.03)
6ES7155-5AA01-0AB0 from V4.1 250 µs 512 Byte 240 Byte from V4.1 from V4.1 − − from V4.13)
IM 155-5 PN HF 6ES7155-5AA00-0AC0 from V1.0 250 µs 512 Byte 240 Byte from V1.0 from V1.0 − − from V1.03)
ET 200AL
IM 157-1 PN 6ES7157-1AB00-0AB0 from V1.0 250 µs 1430 Byte 240 Byte − from V1.0 from V1.0 from V1.0 from V1.02)
ET 200S
IM 151-3 PN ST 6ES7151-3AA23-0AB0 from V6.0 250 µs 256 Byte 240 Byte from V6.0 from V7.0 − − from V7.03)
IM 151-3 PN FO 6ES7151-3BB23-0AB0 from V6.1 250 µs 256 Byte 240 Byte from V6.1 from V7.0 − from V7.0 from V7.03)
IM 151-3 PN HF 6ES7151-3BA23-0AB0 from V6.0 250 µs 256 Byte 240 Byte from V6.0 from V7.0 − from V7.0 from V7.03)
IM 151-3 PN HS 6ES7151-3BA60-0AB0 from V2.0 250 µs 256 Byte 240 Byte from V2.0 from V3.0 − from V3.0 −
ET 200M
IM 153-4 PN ST 6ES7153-4AA01-0XB0 from V2.0 250 µs 192 Byte 240 Byte from V2.0 from V3.0 − − from V3.03)
IM 153-4 PN HF 6ES7153-4BA00-0XB0 from V3.0 250 µs 192 Byte 240 Byte from V3.0 from V3.0 − − from V3.03)
ET 200pro
IM 154-4 PN HF 6ES7154-4AB10-0AB0 from V6.0 250 µs 256 Byte 240 Byte from V6.0 from V7.0 − from V7.0 from V7.03)
IM 154-3 PN HF 6ES7154-3AB00-0AB0 from V7.1 250 µs 256 Byte 240 Byte from V7.1 from V7.1 − from V7.1 from V7.13)
ET 200eco PN
ET 200eco PN 6ES7141-6BF00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7141-6BG00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7141-6BH00-0AB0 from V6.0 250 µs 2 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7142-6BF00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7142-6BF50-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7142-6BG00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7142-6BH00-0AB0 from V6.0 250 µs 2 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7142-6BR00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7144-6KD00-0AB0 from V6.0 250 µs 16 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7145-6HD00-0AB0 from V6.0 250 µs 8 Byte 240 Byte from V6.0 from V7.0 − − −
6ES7147-6BG00-0AB0 from V6.0 250 µs 1 Byte 240 Byte from V6.0 from V7.0 − − −

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 1/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

Module Link to Product information / IRT Min. PROFINET Address area per station Max. record prioritized MRP MRPD PROFIenergy Shared device
Order number
6ES7144-6KD50-0AB0 from V6.0 send
250clock
µs 16 Byte length
240(acyclic)
Byte startup
from V6.0 from V7.0 − − −
6ES7148-6JA00-0AB0 from V6.1 (RT250
andµsIRT) 32 Byte 240 Byte from V6.1 from V7.0 − − −
6ES7148-6JD00-0AB0 from V1.0 250 µs 1 Byte (SIO mode) 240 Byte from V1.0 from V1.0 − − −
32 Byte (IO link mode)
6ES7141-6BG00-0BB0 from V1.0 250 µs depending on the configuration 1/ 2 Byte 240 Byte from V1.0 from V1.0 − − −
6ES7141-6BH00-0BB0 from V1.0 250 µs depending on the configuration 2/ 4 Byte 240 Byte from V1.0 from V1.0 − − −
6ES7142-6BG00-0BB0 from V1.0 250 µs 1 Byte 240 Byte from V1.0 from V1.0 − − from V1.0
6ES7142-6BR00-0BB0 from V1.0 250 µs 1 Byte 240 Byte from V1.0 from V1.0 − − from V1.0
6ES7143-6BH00-0BB0 from V1.0 250 µs depending on the configuration 2/ 6 Byte 240 Byte from V1.0 from V1.0 − − from V1.0
Gateways
PN/PN coupler 6ES7158-3AD01-0XA0 from V2.0 250 µs 1024 Byte 8 kByte from V2.0 from V3.0 − − from V3.03)
6ES7158-3AD10-0XA0 from V4.0 250 µs 1440 Byte 4096 Byte from V4.0 from V4.0 − − from V4.03)
SINAMICS S120
CU320 (CBE20) 6SL3040-0MA00-0AA1 yes 500 µs 400 Bye 240 Byte − − − − −

CU320-2 DP (CBE20) 6SL3040-1MA00-0AA0 yes 500 µs 400 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.3.24)

CU320-2 PN 6SL3040-1MA01-0AA0 yes 250 µs (from V4.5) 480 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.44)

CU 310 PN 6SL3040-0LA01-0AA1 yes 500 µs 400 Bye 240 Byte − − − − −

CU310-2 PN 6SL3040-1LA01-0AA0 yes 250 µs (from V4.5) 480 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.44)

SINAMICS S110
CU305 PN 6SL3040-0JA01-0AA0 yes 500 µs 240 Byte 240 Byte − − − − from V4.44)

CU320 (CBE20) 6SL3040-0MA00-0AA1 yes 500 µs 400 Bye 240 Byte − − − − −

CU320-2 DP (CBE20) 6SL3040-1MA00-0AA0 yes 500 µs 400 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.3.2

CU320-2 PN 6SL3040-1MA01-0AA0 yes 250 µs (from V4.5) 480 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.4

SINAMICS S210
SINAMICS S210, 1AC 230V, 0.1kW 6SL3210-5HB10-1UF0 yes 250 µs 480 Byte 240 Byte − yes yes yes yes

SINAMICS S210, 1AC 230V, 0.2kW 6SL3210-5HB10-2UF0 yes 250 µs 480 Byte 240 Byte − yes yes yes yes

SINAMICS S210, 1AC 230V, 0.4kW 6SL3210-5HB10-4UF0 yes 250 µs 480 Byte 240 Byte − yes yes yes yes

SINAMICS S210, 1AC 230V, 0.75kW 6SL3210-5HB10-8UF0 yes 250 µs 480 Byte 240 Byte − yes yes yes yes

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 2/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

Module Link to Product information / IRT Min. PROFINET Address area per station Max. record prioritized MRP MRPD PROFIenergy Shared device
SINAMICS G120 Order number send clock length (acyclic) startup
CU240S PN 6SL3244-0BA20-1FA0 − (RT 1and
msIRT) 52 Byte 240 Byte − − − − −

CU240S PN-F 6SL3244-0BA21-1FA0 − 1 ms 52 Byte 240 Byte − − − − −

CU240E-2 PN 6SL3244-0BB12-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240E-2 PN-F 6SL3244-0BB13-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU230P-2 PN 6SL3243-0BB30-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240D-2 PN 6SL3544-0FB20-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240D-2 PN-F 6SL3544-0FB21-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240D-2 PN-F PP 6SL3544-0FB21-1FB0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240D-2 PN-F FO 6SL3544-0FB21-1FC0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU240M-2 PN 6SL3544-0xx02-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.7 from V4.7 from V4.7 from V4.74)

CU250D-2 PN-F 6SL3546-0FB21-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU250D-2 PN-F PP 6SL3546-0FB21-1FB0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU250D-2 PN-F FO 6SL3546-0FB21-1FC0 yes 500 µs 52 Byte 240 Byte − from V4.5 from V4.5 from V4.5 from V4.54)

CU250S-2 PN 6SL3246-0BA22-1FA0 yes 500 µs 52 Byte 240 Byte − from V4.6 from V4.6 from V4.6 from V4.64)

SINAMICS V90 (6SL3210-5Fxxx-xxFx)


V90-PN 6SL3210-5FB10-1UF0 yes 500 µs 240 Byte 240 Byte − − − − −
6SL3210-5FB10-2UF0
6SL3210-5FB10-4UF1
6SL3210-5FB10-8UF0
6SL3210-5FB11-0UF1
6SL3210-5FB11-5UF0
6SL3210-5FB12-0UF0
6SL3210-5FE10-4UF0
6SL3210-5FE10-8UF0
6SL3210-5FE11-0UF0
6SL3210-5FE11-5UF0
6SL3210-5FE12-0UF0
6SL3210-5FE13-5UF0
6SL3210-5FE15-0UF0
6SL3210-5FE17-0UF0

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 3/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

Module Link to Product information / IRT Min. PROFINET Address area per station Max. record prioritized MRP MRPD PROFIenergy Shared device
SINAMICS G130 (6SL3310-1G***-***3) Order number send clock length (acyclic) startup
CU320-2 PN 6SL3040-1MA01-0AA0 yes (RT500
andµsIRT) 52 Byte 240 Byte − from V4.8 from V4.8 from V4.8 −
SINAMICS G150 (6SL3710-1G***-***3)
CU320-2 PN 6SL3040-1MA01-0AA0 yes 500 µs 52 Byte 240 Byte − from V4.8 from V4.8 from V4.8 −
SINAMICS S150
CU320-2 PN 6SL3040-1MA01-0AA0 yes 500 µs 52 Byte 240 Byte − from V4.8 from V4.8 from V4.8 −
SINAMICS MV
CU320-2 PN 6SL3040-1MA01-0AA0 yes 500 µs 52 Byte 240 Byte − from V4.7 from V4.7 from V4.7 −
PC CPs
CP 1616 6GK1161-6AA01 from V2.0 250 µs 1433 Byte 4096 Byte from V2.2.0 from V2.2.0 − from V2.6 −
CP 1616 6GK1161-6AA02 from V2.0 250 µs 1433 Byte 4096 Byte from V2.2.0 from V2.2.0 − from V2.6 −
CP 1604 6GK1160-4AA00 from V2.0 250 µs 1433 Byte 4096 Byte from V2.2.0 from V2.2.0 − from V2.6 −
CP1604 6GK1160-4AA01 from V2.0 250 µs 1433 Byte 4096 Byte from V2.2.0 from V2.2.0 − from V2.6 −
SCALANCE X-200 IRT
X200-4P IRT 6GK5200-4AH00-2BA3 from V2.1 − − − − from V2.1 from V5.1 − −
X201-3P IRT 6GK5201-3BH00-2BA3 from V2.1 − − − − from V2.1 from V5.1 − −
X202-2P IRT 6GK5202-2BH00-2BA3 from V2.1 − − − − from V2.1 from V5.1 − −
X202-2 IRT 6GK5202-2BB00-2BA3 from V2.1 − − − − from V2.1 from V5.1 − −
XF204 IRT 6GK5204-0BA00-2BF2 from V2.1 − − − − from V2.1 from V5.1 − −
X201-3P IRT PRO 6GK5201-3JR00-2BA6 from V2.1 − − − − from V2.1 from V5.1 − −
X202-2P IRT PRO 6GK5202-2JR00-2BA6 from V2.1 − − − − from V2.1 from V5.1 − −
X204 IRT 6GK5204-0BA00-2BA3 from V2.1 − − − − from V2.1 from V5.1 − −
X204 IRT PRO 6GK5204-0JA00-2BA6 from V2.1 − − − − from V2.1 from V5.1 − −
XF204-2BA IRT 6GK5204-2AA00-2BD2 from V5.3 − − − − from V5.3 from V5.3 − −

1)
Isochronous mode on SIMATIC CPU S7-300 with firmware V3.2 and higher and S7-400 with firmware V6.0 and higher
2)
With STEP 7 V12 SP1 and higher the projection of the "Shared device" function (up to 4 IO controller) is supported via GSD file.
3)
With STEP 7 V12 SP1 and higher the projection of the "Shared device" function (up to 2 IO controller) is supported via GSD file.
4)
Standard telegrams have to be assign to the Standard CPU and PROFIsafe telegrams have to be assign to the F-CPU.
5)
Module-internal Shared Input / Shared Output (MSI / MSO)
6)
The "Isochronous mode" function and the "Shared device" function can`t be use parallel on IO device.
7)
This I/O data length is the minimum which can be used in total regardless of the type and number of I/O modules or module distribution to submodules.
8)
From FW V4.2 the Isochronous Mode and the "Shared device" function can be used combined.

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 4/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

MSI/MSO5) Isochronous mode6) Min. cycle time of Max. number of SERVO drives System redundancy Konfigurationssteuerung
isochronous mode OBs (plus 1 Active Line central distributed
(Isochronous mode) Module (ALM) by S120)

− − − − − − from V3.2
from V3.1 − − − − − from V1.0
from V4.1 − − − − − from V4.1
from V2.2 from V2.18) 250 µs − from V3.0 − from V2.0

from V4.2 from V4.28) 250 µs − from V4.2 − from V4.2

from V4.2 from V4.28) 250 µs − from V4.2 − from V4.2

from V4.0 from V4.0 125 µs − − − from V4.0


− − − − from V1.0 − −

from V4.0 − − − − − from V4.0


from V2.0 from V1.0 250 µs − − − from V1.0
from V4.1 from V4.1 250 µs − − − from V4.1
from V1.0 from V1.0 250 µs − from V1.0 − from V1.0

− − − − − − from V1.0

− − − − − − from V6.0
− − − − − − from V6.1
− − − − − − from V6.0
− from V3.01) 125 µs − − − −

− − − − − − −
− − − − from V4.0 − −

− − − − − − from V7.1
− − − − − − from V7.1

− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −
− − − − − − −

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 5/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

MSI/MSO5) Isochronous mode6) Min. cycle time of Max. number of SERVO drives System redundancy Konfigurationssteuerung
− − isochronous − mode OBs (plus 1 Active
− Line − − −
− − (Isochronous
− mode) Module (ALM)
− by S120) − − −
− − − − − − −

from V1.0 from V1.0 250 µs − from V1.0 − from V1.0


from V1.0 from V1.0 250 µs − from V1.0 − from V1.0
from V1.0 from V1.0 250 µs − from V1.0 − from V1.0
from V1.0 from V1.0 250 µs − from V1.0 − from V1.0
from V1.0 − − − from V1.0 − from V1.0

− − − − − − −
− − − − − − −

− yes 500 µs 5 − Activate/Deactivate components and technology


objects
− yes 500 µs 6 − Activate/Deactivate components and technology
objects
− yes 250 µs (from V4.5) 6 − Activate/Deactivate components and technology
objects
− yes 500 µs 1 − Activate/Deactivate components and technology
objects
− yes 250 µs (from V4.5) 1 − Activate/Deactivate components and technology
objects

− yes 1 ms 1 − Activate/Deactivate components and technology


objects
− yes 500 µs − − Activate/Deactivate components and technology
objects
− yes 500 µs − − Activate/Deactivate components and technology
objects
− yes 250 µs (from V4.5) − − Activate/Deactivate components and technology
objects

− yes 250 µs 1 − Activate/Deactivate components and technology


objects
− yes 250 µs 1 − Activate/Deactivate components and technology
objects
− yes 250 µs 1 − Activate/Deactivate components and technology
objects
− yes 250 µs 1 − Activate/Deactivate components and technology
objects

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 6/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

MSI/MSO5) Isochronous mode6) Min. cycle time of Max. number of SERVO drives System redundancy Konfigurationssteuerung
isochronous mode OBs (plus 1 Active Line
− − (Isochronous
− mode) Module (ALM)
1 (only by S120)
"vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (only "vector") − Activate/Deactivate components and technology
objects
− − − 1 (from V4.6, only "vector") − Activate/Deactivate components and technology
objects

− yes 2 ms 1 − − −

This entry is from the Service&Pupport portal of Siemens AG,


Change date: 10/22/2020 Siemens Industry Online Support. Page: 7/8
The general terms of use (http://www.siemens.com/terms_of_use) apply.
Which IO devices support the functions IRT, prioritized startup, MRP, MRPD, PROFIenergy,
s Shared device, MSI/MSO, I device, Isochronous mode, System redundancy and Option handling?
Entry-ID: 102325771

MSI/MSO5) Isochronous mode6) Min. cycle time of Max. number of SERVO drives System redundancy Konfigurationssteuerung
isochronous mode OBs (plus 1 Active Line
− − (Isochronous
− mode) Module (ALM)
− by S120) − − −

− − − − − − −

− − − − − − −

− − − − − − −

− yes 250 µs − − − −
− yes 250 µs − − − −
− yes 250 µs − − − −
− yes 250 µs − − − −

− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −
− − − − − −