KEITH PANEL SYSTEMS

S Y S T E M D E T A I L S

FUNDERMAX- MAX EXTERIOR


CONCEALED FASTENERS
PRESSURE EQUALIZED WALL SYSTEM
KEITH PANEL SYSTEMS

PAGE TITLE PAGE

Table of Contents 1
Fundermax Max Exterior Product Information 2
Design and Installation Information 3, 4
Sample Elevation 5
Typical Vertical Joint 6
Outside Corner 7
Inside Corner 8
Window Jamb 9
Typical Horizontal Joint 10
Mid-panel Fastener Support 11
Base 12
Window Sill 13
Window Head 14
Floor Slab Deflection and Thru-wall Flashing 15
Parapet 16

TABLE OF CONTENTS 1 OF 16
KEITH PANEL SYSTEMS

TECHNICAL DATA Test Method

Density 1.35 g/cm3 EN ISO 1183-1


Flexural Strength 80 MPa EN ISO 178
Modulus of Elasticity ~9000 MPa EN ISO 178
Tensile Strength 60 MPa EN ISO 527-2
Thermal Expansion Coefficient 18x10-6 1K DIN 52328

Fire Behavior Euroclass B-s2, d0 for 6-10mm EN 13501-1

Weight - 10mm (3 8") thickness ~13.5 kg/m² ~2.77 lbs/ft²

PANEL SIZES imperial values

110" x 51" Expansion / Contraction


GR 2800 x 1300
Max Exterior shrinks when it loses moisture and expands
SP 2800 x 1854 110" x 73" when it absorbs moisture. Calculate: overall length ÷ 500
JU 4100 x 1300 161" x 51" = change in length
XL 4100 x 1854 161" x 73" Curved Max Exterior Panels
Top and bottom edge profiles (2mm thick) must be
pre-bent. Only sliding line fastenings are allowed (no
point fastenings). The straight ends and joints of the
exterior panels must likewise be edged. (U-profile,
Tolerances +10mm -0mm (EN 438-6,5.3) Panel formats H-profile).
are production formats. If exact dimensions and angles
are necessary, we recommend an all-sided blank. Min. radius 3m(9'-10") and min. length 1.3m(4'-3").
Edge Processing Sealent
To mill bevels electric hand planes with bevel or bevel The use of sealant compounds must be avoided as they
grooves can be used or hand routers. can cause permanent staining to Max Exterior panels.

MAX EXTERIOR PRODUCT 2 OF 16


INFORMATION
KEITH PANEL SYSTEMS
Panel Joints Panel Attachment Layout
To be minimum 8mm wide for vertical and horizontal Spacing of brackets to be spread equally on panel. See
joints. The wider any joint, the less noticeable are below for edge distance and spacing requirements.
inaccuracies in width. Therefore typical joint width used is
13mm.
Ventilation Cavity Intake/Exhaust
Air cavity ventilation openings provided at the base and
top of the wall area and at any additional interruptions for
example window heads and sills.
Panel Attachment
Installation of Max Exterior panels using concealed,
mechanical fastening brackets on an aluminum rail.

Max Exterior panel thickness: 10 and 12mm


Anchoring depths: 10mm thick panels 4mm
12mm thick panels 6mm

Single span panel.

Double span panel.


Minimum distance to panel edge:
Horizontal and Vertical = 20mm (13 16")

Maximum distance to panel edge:


Horizontal and Vertical = 80mm (318")

Engineering Loads Max Exterior bracket spacings

Single span Double span


A = 700mm (27.5") A = 700mm (27.5")
0.50 kN/m² B = 700mm (27.5") B = 700mm (27.5")
A = 539mm (21.2") A = 399mm (15.7")
1.00 kN/m² B = 700mm (27.5") B = 700mm (27.5")
A = 373mm (14.7") A = 320mm (12.6")
1.50 kN/m² B = 700mm (27.5") B = 700mm (27.5")
A = 280mm (11.0") A = 293mm (11.5")
2.00 kN/m² B = 700mm (27.5") B = 700mm (27.5")

DESIGN AND INSTALLATION 3 OF 16


INFORMATION
KEITH PANEL SYSTEMS
Max Exterior Panel Expansion/Contraction
To allow expansion and contraction between the
substructure and panels, all brackets are floating. In
order to hold up the panel, 1 bracket is fixed by
mechanical fastener. In addition to the fixed bracket, a
loose point is placed in the same level. Position of the
fixed and loose points will be determined on shop
drawings.

Site Fabricating Panels


Avoid using tools which produce fine dust. Always work
out of the weather. Always drill/cut perpendicularly to the
panel surface. Use circular saw with straight edge with
dust extraction. For best cut use a Blad hard metal teeth
TF or diamond tipped saw blade. Use jig say for hole cut
outs in panel. Dust from fabrication must be removed
from panel surface immediately following cutting.
Site Storage
Max Exterior panels must be stacked horizontally on flat,
stable supports and supporting panels. The goods must
lie completely flat.

Cover plates must always be left on the stack. The top


cover should be weighted down. After removal of panels,
PE films must again be closed over tyhe stack. The same
applies, in principle, for cut-panel stacks. Incorrect
storage can lead to permanent deformation of the panels.

Max Exterior panels are to be stored in closed rooms


under normal climatic conditions. Climate differences on
the two surfaces of a panel are to be avoided.

With pre-installed fastening elements, therefore, care is to


be taken that the climatic effect is uniform on all sides.
Use intermediate layers of wood or plastic.

DESIGN AND INSTALLATION 4 OF 16


INFORMATION
KEITH PANEL SYSTEMS

SAMPLE ELEVATION 5 OF 16
KEITH PANEL SYSTEMS

TYPICAL VERTICAL JOINT 6 OF 16


KEITH PANEL SYSTEMS

OUTSIDE CORNER 7 OF 16
KEITH PANEL SYSTEMS

INSIDE CORNER 8 OF 16
KEITH PANEL SYSTEMS

WINDOW JAMB 9 OF 16
KEITH PANEL SYSTEMS

TYPICAL HORIZONTAL JOINT 10 OF 16


KEITH PANEL SYSTEMS

MID-PANEL FASTENER SUPPORT 11 OF 16


KEITH PANEL SYSTEMS

BASE 12 OF 16
KEITH PANEL SYSTEMS

WINDOW SILL 13 OF 16
KEITH PANEL SYSTEMS

WINDOW HEAD 14 OF 16
KEITH PANEL SYSTEMS

FLOOR SLAB DEFLECTION 15 OF 16


& THRU-WALL FLASHING
KEITH PANEL SYSTEMS

PARAPET 16 OF 16