Safety Data Sheet: Masterflow 555 Grout
Safety Data Sheet: Masterflow 555 Grout
Safety Data Sheet: Masterflow 555 Grout
1. Identification
* The “Recommended use” identified for this product is provided solely to comply with a Federal requirement and is not part of
the seller's published specification. The terms of this Safety Data Sheet (SDS) do not create or infer any warranty, express or
implied, including by incorporation into or reference in the seller's sales agreement.
Company:
BASF CORPORATION
100 Park Avenue
Florham Park, NJ 07932, USA
CHEMTREC: 1-800-424-9300
BASF HOTLINE: 1-800-832-HELP (4357)
2. Hazards Identification
According to Regulation 2012 OSHA Hazard Communication Standard; 29 CFR Part 1910.1200
Label elements
Pictogram:
Signal Word:
Danger
Hazard Statement:
H318 Causes serious eye damage.
H315 Causes skin irritation.
H335 May cause respiratory irritation.
H350 May cause cancer by inhalation.
H373 May cause damage to organs (Kidney, Immune system) through
prolonged or repeated exposure (inhalation).
H372 Causes damage to organs (lung) through prolonged or repeated
exposure (inhalation).
If applicable information is provided in this section on other hazards which do not result in
classification but which may contribute to the overall hazards of the substance or mixture.
Safety Data Sheet
MasterFlow 555 GROUT
Revision date : 2019/05/20 Page: 3/11
Version: 4.0 (30367913/SDS_GEN_US/EN)
4. First-Aid Measures
General advice:
First aid personnel should pay attention to their own safety. If the patient is likely to become
unconscious, place and transport in stable sideways position (recovery position). Immediately
remove contaminated clothing.
If inhaled:
Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a
corticosteroid from a controlled/metered dose inhaler.
If on skin:
Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist.
If in eyes:
Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open,
consult an eye specialist.
If swallowed:
Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention.
Symptoms: The most important known symptoms and effects are described in the labelling (see
section 2) and/or in section 11.
Hazards: No applicable information available.
Note to physician
Treatment: Treat according to symptoms (decontamination, vital functions), no
known specific antidote.
5. Fire-Fighting Measures
Extinguishing media
Safety Data Sheet
MasterFlow 555 GROUT
Revision date : 2019/05/20 Page: 4/11
Version: 4.0 (30367913/SDS_GEN_US/EN)
Additional information:
Product itself is non-combustible. Only the packaging materials can catch fire. The extinguishing
agents normally used are sufficient.
Further information:
Product itself is non-combustible; fire extinguishing method of surrounding areas must be
considered. The degree of risk is governed by the burning substance and the fire conditions. Dispose
of fire debris and contaminated extinguishing water in accordance with official regulations.
Environmental precautions
Do not discharge into drains/surface waters/groundwater.
Further information on storage conditions: Containers should be stored tightly sealed in a dry place.
Silicon dioxide OSHA PEL TWA value 6 mg/m3 ; TWA value 20 millions of
particles per cubic foot of air ; TWA value 0.8
mg/m3 ;
The exposure limit is calculated from the
equation, 80mg/m3)/(%SiO2), using a value of
100% SiO2. Lower percentages of SiO2 will yield
higher exposure limits.
Gypsum (Ca(SO4).2H2O) OSHA PEL PEL 15 mg/m3 Total dust ; PEL 5 mg/m3
Respirable fraction ; TWA value 15 mg/m3
Total dust ; TWA value 5 mg/m3 Respirable
fraction ;
ACGIH TLV TWA value 10 mg/m3 Inhalable fraction ;
Cement, portland, OSHA PEL PEL 15 mg/m3 Total dust ; PEL 5 mg/m3
chemicals Respirable fraction ; TWA value 10 mg/m3
Total dust ; TWA value 5 mg/m3 Respirable
fraction ; TWA value 50 millions of particles per
cubic foot of air ;
ACGIH TLV TWA value 1 mg/m3 Respirable fraction ;
The value is for particulate matter containing no
asbestos and <1% crystalline silica.
Quartz (SiO2) OSHA PEL TWA value 0.05 mg/m3 (Respirable dust);
OSHA Action level 0.025 mg/m3 (Respirable
dust);
ACGIH TLV TWA value 0.025 mg/m3 Respirable fraction ;
Hand protection:
Chemical resistant protective gloves, Manufacturer's directions for use should be observed because
of great diversity of types.
Eye protection:
Tightly fitting safety goggles (chemical goggles).
Body protection:
Body protection must be chosen based on level of activity and exposure.
Form: powder
Odour: mild
Odour threshold: Not determined due to potential health hazard by inhalation.
Colour: grey
pH value: 13
( 20 °C)
(as aqueous solution)
Melting point: not applicable
Boiling point: No applicable information available.
Sublimation point: No applicable information available.
Flash point: Non-flammable.
Flammability: not determined
Lower explosion limit: As a result of our experience with this
product and our knowledge of its
composition we do not expect any
hazard as long as the product is used
appropriately and in accordance with
the intended use.
Upper explosion limit: As a result of our experience with this
product and our knowledge of its
composition we do not expect any
hazard as long as the product is used
appropriately and in accordance with
the intended use.
Autoignition: No applicable information available.
Vapour pressure: No applicable information available.
Relative density: No applicable information available.
Bulk density: 1.25 g/cm3
Vapour density: No applicable information available.
Partitioning coefficient n- No applicable information available.
octanol/water (log Pow):
Safety Data Sheet
MasterFlow 555 GROUT
Revision date : 2019/05/20 Page: 7/11
Version: 4.0 (30367913/SDS_GEN_US/EN)
Self-ignition not self-igniting
temperature:
Thermal decomposition: No decomposition if stored and handled as
prescribed/indicated.
Viscosity, dynamic: No applicable information available.
Viscosity, kinematic: No applicable information available.
Solubility in water: ( 15 °C)
insoluble
Miscibility with water: ( 15 °C)
immiscible
Solubility (quantitative): No applicable information available.
Solubility (qualitative): No applicable information available.
Evaporation rate: No applicable information available.
Other Information: If necessary, information on other physical and chemical
parameters is indicated in this section.
Reactivity
No hazardous reactions if stored and handled as prescribed/indicated.
Oxidizing properties:
Based on its structural properties the product is not classified as oxidizing.
Chemical stability
The product is stable if stored and handled as prescribed/indicated.
Conditions to avoid
Avoid dust formation. Avoid humidity.
Incompatible materials
strong bases, strong acids
Decomposition products:
No hazardous decomposition products if stored and handled as prescribed/indicated.
Thermal decomposition:
No decomposition if stored and handled as prescribed/indicated.
Routes of entry for solids and liquids are ingestion and inhalation, but may include eye or skin
contact. Routes of entry for gases include inhalation and eye contact. Skin contact may be a route
of entry for liquefied gases.
Acute Toxicity/Effects
Acute toxicity
Safety Data Sheet
MasterFlow 555 GROUT
Revision date : 2019/05/20 Page: 8/11
Version: 4.0 (30367913/SDS_GEN_US/EN)
Assessment of acute toxicity: Virtually nontoxic after a single ingestion. Virtually nontoxic after a
single skin contact. Virtually nontoxic by inhalation. The product has not been tested. The statement
has been derived from the properties of the individual components.
Oral
No applicable information available.
Inhalation
No applicable information available.
Dermal
No applicable information available.
Irritation / corrosion
Assessment of irritating effects: Skin contact causes irritation. May cause severe damage to the
eyes.
Sensitization
Assessment of sensitization: There is no evidence of a skin-sensitizing potential. The product has
not been tested. The statement has been derived from the properties of the individual components.
Chromate in this product has been reduced. Sensitization due to chromate within stated shelf-live is
unlikely.
Aspiration Hazard
No aspiration hazard expected.
Chronic Toxicity/Effects
Carcinogenicity
Assessment of carcinogenicity: May cause cancer.
Reproductive toxicity
Safety Data Sheet
MasterFlow 555 GROUT
Revision date : 2019/05/20 Page: 9/11
Version: 4.0 (30367913/SDS_GEN_US/EN)
Assessment of reproduction toxicity: The chemical structure does not suggest a specific alert for
such an effect. Based on available Data, the classification criteria are not met.
Teratogenicity
Assessment of teratogenicity: The chemical structure does not suggest a specific alert for such an
effect. Based on available Data, the classification criteria are not met.
Other Information
The product has not been tested. The statements on toxicology have been derived from the
properties of the individual components.
Symptoms of Exposure
The most important known symptoms and effects are described in the labelling (see section 2)
and/or in section 11.
Toxicity
Aquatic toxicity
Assessment of aquatic toxicity:
There is a high probability that the product is not acutely harmful to aquatic organisms.
The product gives rise to pH shifts. Based on available Data, the classification criteria are not met.
Elimination information
not determined
Bioaccumulative potential
Mobility in soil
Additional information
Container disposal:
Completely emptied packagings can be given for recycling.
Sea transport
IMDG
Not classified as a dangerous good under transport regulations
Air transport
IATA/ICAO
Not classified as a dangerous good under transport regulations
Federal Regulations
Registration status:
Chemical TSCA, US released / listed
EPCRA 311/312 (Hazard categories): Refer to SDS section 2 for GHS hazard classes applicable
for this product.
WARNING: This product can expose you to chemicals including SILICA, CRYSTALLINE
(AIRBORNE PARTICLES OF RESPIRABLE SIZE), which is known to the State of California to
cause cancer. For more information, go to www.P65Warnings.ca.gov.
We support worldwide Responsible Care® initiatives. We value the health and safety of our
employees, customers, suppliers and neighbors, and the protection of the environment. Our
commitment to Responsible Care is integral to conducting our business and operating our facilities in
a safe and environmentally responsible fashion, supporting our customers and suppliers in ensuring
the safe and environmentally sound handling of our products, and minimizing the impact of our
operations on society and the environment during production, storage, transport, use and disposal of
our products.