Operator'S Manual: Ship Security Alert System (Ssas) USCG Version

This document provides an operator's manual for a Ship Security Alert System (SSAS). It describes the system configuration which includes up to 3 SSAS alert units that can transmit distress signals via INMARSAT. It also covers installation and wiring of the units, setting the destination and contents of SSAS reports, transmitting test alerts, and waterproofing the system.

Uploaded by

Trusted2018
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views31 pages

Operator'S Manual: Ship Security Alert System (Ssas) USCG Version

This document provides an operator's manual for a Ship Security Alert System (SSAS). It describes the system configuration which includes up to 3 SSAS alert units that can transmit distress signals via INMARSAT. It also covers installation and wiring of the units, setting the destination and contents of SSAS reports, transmitting test alerts, and waterproofing the system.

Uploaded by

Trusted2018
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 31

OPERATOR'S MANUAL

SHIP SECURITY
ALERT SYSTEM (SSAS)
USCG Version

MODEL IC-307

www.furuno.co.jp
The paper used in this manual
is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN

All rights reserved. Printed in Japan A : AUG . 2005


C : JAN . 07, 2013
Pub. No. OME-56352-C
(AKMU ) IC-307(USCG Version) *00015716012*
*00015716012*
* 0 0 0 1 5 7 1 6 0 1 2 *
TABLE OF CONTENTS

SYSTEM CONFIGURATION ..................................................................................... ii

1. OVERVIEW OF SSAS .......................................................................................... 1

2. INSTALLATION..................................................................................................... 3
2.1 Mounting ........................................................................................................................... 3
2.1.1 Junction box (for FELCOM 16/19) ........................................................................... 3
2.1.2 SSAS alert unit......................................................................................................... 4
2.2 Wiring................................................................................................................................ 6
2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6
2.2.2 SSAS alert unit......................................................................................................... 7
2.3 Enabling USCG Version.................................................................................................... 8

OPERATION ......................................................................................................... 9
3.1 Operation Mode ................................................................................................................ 9
3.1.1 Changing the password............................................................................................ 9
3.1.2 SSAS manager mode ............................................................................................ 10
3.2 Setting SSAS Report Destination and Message Contents ..............................................11
3.3 Transmitting SSAS Report .............................................................................................. 15
3.4 Testing the Button ........................................................................................................... 16
3.5 SSAS Report Test ........................................................................................................... 20

4. WATERPROOFING KIT...................................................................................... 21

OUTLINE DRAWINGS........................................................................................... D-1


INTERCONNECTION DIAGRAMS.........................................................................S-1

i
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15

ANTENNA
UNIT
IC-115

DGPS

EGC Printer 24 VDC


100-115/200-230 VAC PP-505
TERMINAL UNIT
1φ, 50/60 Hz IC-215
AC-DC Power Supply Personal
Computer Printer
24 VDC PR-240-CE*1
(PC/AT compatible)
GPS receiver
12-24 VDC OP16-24 Shipboard LAN (Ethernet)

Printer
24 VDC
PP-510

Mini Keyboard Distress Alert/


Received Call Unit
IC-305
SSAS Alert Unit SSAS Alert Unit
IC-307 IC-307 JUNCTION
BOX Alarm Unit
(Max. 3 units) IC-306
IC-315
SSAS Alert Unit
IC-307 : Standard Supply
Navigator
: Option
*1 Any AC-DC power supply
: Local Supply
fulfilling requirements of
IEC 60945 may be used.

FELCOM 16
ANTENNA
UNIT
IC-116

100-115/200-230 VAC AC-DC PRINTER


1φ, 50/60 Hz Power Supply
PR-240-CE*1 COMMUNICATION UNIT IC-216
24 VDC (with internal GPS receiver)
FURUNO INMARSAT MINI-C MOBILE EARTH STATION
PERSONAL
ER

R
IN

RO
W

COMPUTER
PO

LO

ER
TX

12-24 VDC O POWER I

(PC/AT compatible)

SSAS Alert Unit SSAS Alert Unit SSAS Alert Unit JUNCTION BOX : Standard
IC-307 IC-307 IC-307 IC-315 : Option
: Local Supply
(Max. 3 units)

ii
FELCOM 18

ANTENNA
UNIT
IC-118

TERMINAL
UNIT
DGPS
AC-DC Power Supply IC-218
PR-240

GPS Board PC
12/24 VDC OP16-62
(built-in)
Printer Shipboard LAN
PP-510** (Ethernet)
For 12 VDC power,
DC-DC converter is Mini keyboard
required to use PP-510. 5139U
JUNCTION BOX Navigator
IC-318
Distress Alert/
Received Call Unit
IC-305/IC-350
SSAS Alert Unit SSAS Alert Unit SSAS Alert Unit Alarm Unit
IC-307 IC-307 IC-307 IC-306
Max. 3 units

FELCOM 19

ANTENNA
UNIT
IC-119
AC-DC
Power Supply
PR-240
SHIP'S MAINS
12-24 VDC PERSONAL
COMPUTER
(Windows OS)
COMMUNICATION UNIT IC-219
(with internal GPS receiver)
* At least two SSAS Alert Units
JUNCTION BOX are required.
IC-318
NAVIGATOR
(GLONASS
SSAS ALERT UNIT compliant)
IC-307*

SSAS ALERT UNIT


IC-307*

iii
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/18 or the Inmarsat Mini-C FELCOM 16/19 for the purpose of alerting specified
addresses (for example, your ship’s company) that your ship is under attack by intruders.
The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01
July 2004 to install an SSAS.

When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.

The SSAS is protected with a password to prevent unauthorized setting or testing of it by


other than the ship’s captain or authorized personnel.
Inmarsat System

Ship Name, MMSI No.,


Ship Position, etc.

USCG station

1
SSAS operation flow

1. Open the cover and press button one second.


SSAS report is immediately transmitted.

2. An LES sends acknowledgement to your ship.


3. SSAS report is automatically sent to multiple addresses if applicable.

4. Repeated transmission of the SSAS report begins. The interval at


which to transmit the SSAS report to each address can be specifed.
The SSAS report is continuously transmitted at the interval selected.

5. To cancel repeated transmission:

Terminal unit: Turn off the communication unit. Press and hold down
the button on the SSAS unit while turning on the communication unit.
Release the button when the test mode starts. (The FELCOM 16 goes
into the button test mode.)
Note that if there are any unsent messages they are sent and then the
system goes into normal operation; namely, the test mode is not
activated.

PC: Open the SSAS manager (see page 10) and input the command
TERMINATE SSAS ALERT.

2
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16/19)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16/19; it is
already installed on the FELCOM 15/18.

Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.

IC-315 IC-318
Standard compass: 1.0 m Standard compass: 0.90 m
Steering compass: 0.70 m Steering compass: 0.90 m

1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.

120 ±0.5

70 ±0.5

Junction box IC-315/318


The junction box is connected to the communication cnit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

3
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.

Standard compass: 0.70 m


Steering compass: 0.45 m

Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.

Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.

Unfasten three screws.

Clamp

Rotate

Fasten three screws.

4. Run the cable thru one of the cable entrances and connect it to terminal board.

4
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180
degrees.

Switch cover

Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1 100-317-931 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.

5
2.2 Wiring
2.2.1 Junction box (for FELCOM 16/19)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the
junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four
screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.

For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see
next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with the junction box. For connecting the communication unit
IC-216, use cable 16S0344.

IC-315 IC-318
1 Vcc 1 Vcc

IC-305/306

IC-305/306
2 GND 2 GND
3 TD/RD-A 3 TD/RD-A
4 TD/RD-B 4 TD/RD-B
Cover 5 NC 5 NC
6 TD-A(NAV) 6 ALM-H
7 TD-B(NAV) 7 ALM-C
8 RD-A(NAV) 8 RD-A(NAV)
9 RD-B(NAV) 9 RD-B(NAV)
10 GND 10 GND
11 DMC OUT-H 11 SSAS OUT-H
Cable clamp 12 DMC OUT-C 12 SSAS OUT-C
(top) 13 DMC IN-H 13 SSAS IN-H
14 DMC IN-C 14 SSAS IN-C
15 DMC CTR 15 SSAS CTR
Terminal
board
Communication 1
Unit 2
Cable clamp Cable clamp
(bottom)

3 Core 7 mm

Fold back braided shield onto Procedure


sheath and fix by cable clamp.
1. Insert driver from direction 1 .
16S0344
2. Tilt slightly toward 2 .
15mm 90mm 7mm 3. Insert cable core to 3 .
Connect the drain wire of the TTYCSLA cables
Note 1: Do not insert the cable too
with the screw and crimp-on lugs provided.
deeply, to prevent pinching the sheath.
Screw, crimp-on lug
(pre-fitted at factory) Note 2: Pull each cable slightly to con-
firm that they are in their holes securely.

IC-318 (inside)

6
2.2.2 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18)
and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in
error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR
lamp (FELCOM 16) flashes.

Junction
Box
IC-307 IC-307 IC-307
(No.1) (No. 2) (No. 3)

Connect wiring to the terminal board 16P0229 inside the SSAS alert unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307 Jumper settings for three IC-307
Unit No.1 unit*
Jumper No. 2 unit *: Default Jumper Unit No.1 unit* No. 2 unit* No. 3 unit
JP1 No Yes setting JP1 No No Yes
JP2 Yes No JP2 Yes Yes No
No. 1 unit: Unit with two cables connnected to it. No. 1 and No. 2 units: Units with two cables connnected to them.
No. 2 unit: Unit with one cable connnected to it. No. 3 unit: Unit with one cable connnected to it.

Two IC-307: No. 2 unit Two IC-307: No. 1 unit


Three IC-307: No. 3 unit Three IC-307: No. 1 and No. 2 units

16P0229 16P0229
JP1 JP2 JP1 JP2

1 2 3 4 5 6 1 2 3 4 5 6

IC-307 IC-307
Cable Fabrication

Twist shield.
Clamp for cable
CO-SPEVV-SB-C CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
0.2x5P
Cut and tape
unused wires 15 mm 40 mm 10 mm
to prevent short.
φ = 16.3 mm
Clamp for cable Armor
TTYCS-4
or equivalent Sheath
Shield
Conductor
S = 0.75 mm2
φ = 1.11 mm
Sectional view of cable TTYCS-4

Wiring inside the SSAS alert unit

7
2.3 Enabling USCG Version
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** [ Main Menu ]
[ Main Menu ] 1. Remote Box Setup
1. Remote Box Setup 2. Internal GPS Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :

FELCOM 15/16 FELCOM 18/19

3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
[ DMC ] [ SSAS ]
1. SSAS(IC-307) 1. ON(IC-307)
2. DMC 2. OFF
3. OFF 3: Momentary SW (for USCG)
4: SSAS(Momentary SW) E: Exit E: Exit
Enter No.: Enter No.:

FELCOM 15 FELCOM 16

[ SSAS ] [ SSAS]
1. OFF 1. OFF
2. IC-307 (Standard SSAS) 2. IC-307(Standard)
3: IC-307 (Russia SSAS) 3: IC-307(Russian)
4: SSAS (Momentary SW) 4: Momentary SW (for USCG)
E: Exit E: Exit
Enter No.: Enter No.:

FELCOM 18 FELCOM 19

6. Press [4] (FELCOM 15) or [3] (FELCOM 16/18/19) to enable the USCG version.
7. Press the [Esc] key several times to close the menu.

8
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:

Normal mode: Menus other than SSAS-related menus are displayed.


SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated, and it is flashing. All SSAS-related menus are available.
Transmission of the SSAS report may be cancelled in this mode.
The equipment starts up in the normal mode, regardless of the
mode in use when the power is turned off.

3.1.1 Changing the password


The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:

1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window Command Window
RFCONCPU *** [ Main Menu ]
[ Main Menu ] 1. Remote Box Setup
1. Remote Box Setup 2. Internal GPS Setup
2. Internal GPS Setup Enter JOB No. :
Enter JOB No. :

FELCOM 15/16 FELCOM 18/19

3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered, the message “Please use a longer
password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.

Note: The SSAS manager mode cannot be accessed without the correct password.

9
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.

1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18.19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
[ DMC ] [ SSAS ]
1. SSAS(IC-307) 1. ON(IC-307)
2. DMC 2. OFF
3. OFF 3: Momentary SW (for USCG)
4: SSAS(Momentary SW) E: Exit E: Exit
Enter No.: Enter No.:

FELCOM 15 FELCOM 16/18/19


3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, the message "Command Ignored: No
SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.

<Press ESC key to continue>

5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.

Note: Turn the power off and on again whenever changing SSAS-related settings.

10
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 5)
and message content set with SSAS Report 1 – SSAS Report 5 on the SSAS Report menu.
Note 1: The destination and message content of an SSAS report vary according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.

Reports Reports
1. Data Report 1. Data Report
2. Message Report 2. Message Report
3. Data Network ID 3. Enhanced Pre-Assigned Data Report (EPADR)
4. SSAS Report 4. Data Network ID
5. SSAS Report
FELCOM 15/16
FELCOM 18/19

2. Press the [4] key to shown the SSAS Report menu.


SSAS Report
1. SSAS Report 1
2. SSAS Report 2
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
6. Message Contents

3. Press [1], [2], [3], [4] or [5] key as appropriate and then window below appears.
SSAS Report SSAS Report
Status ON Status ON
Mode Real+Test Mode Real+Test
Station Name Station Name
Destination Type TELEX Destination Type TELEX/MES
Prefix Code Prefix Code
Country/Ocean Code Country/Ocean Code
Station ID Destination
Modem Type Modem Type
Address Address
Subject Subject
LES ID LES ID
Report Interval 02:00 (hh: mm) Report Interval 02:00

FELCOM 15/16 FELCOM 18/19

11
4. Press the [↓] key to choose Mode and then press the [Enter] key.

Real+Test
Real Only
Test Only

5. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
Test Only: Test SSAS report only.
6. Press the [↓] key to choose Station Name and then press the [Enter] key.
7. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or
descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
8. Press the [↓] key to choose LES ID and then press the [Enter] key.
9. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the
SSAS report is transmitted to that LES.
10. Press the [↓] key to choose Report Interval and then press the [Enter] key.
11. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
12. Press the [Esc] key to open the Update window .

Update

Yes No

13. Yes is selected; press the [Enter] key to close the SSAS report window.

12
14. Press the [6] key to display the SSAS Message Contents menu.
SSAS Message Contents
Vessel Name : ______________________________
MMSI : _________
IMN : _________
Other Inf. : _______________________________________________________
_______________________________________________________
_______________________________________________________
LAT: 34: 44. 46N
LON: 135: 21. 26E
Time: 02/04/2012 04:31:48 (UTC)
COURSE: 071 deg
SPEED: 00 kt
Time: 02/04/2012 04:31:48 (UTC)

FELCOM 15/16
SSAS Message Contents
Vessel Name : ______________________________
MMSI : _________
IMN _________
IMO : _________
Other Inf. : ___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
LAT: 34: 44. 46N
LON: 135: 21. 26E
Time: 02/04/2012 04:31:48 (UTC)
COURSE: 071 deg
SPEED: 00 kt
Time: 02/04/2012 04:31:48 (UTC)

FELCOM 18/19
15. Press the [Enter] key to open the Vessel Name window.
16. Enter vessel’s name and then press the [Enter] key.
17. Press the [↓] key to choose MMSI and then press the [Enter] key.
18. Enter MMSI number and then press the [Enter] key.
19. Press the [↓] key to choose IMN and then press the [Enter] key.
20. Enter IMN and then press the [Enter] key.
21. Press the [↓] key to choose Other Inf. and then press the [Enter] key
22. Enter appropriate message (for FELCOM15/16: three lines, for FELCOM18/19: six lines)
and then press the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
23. Press the [Esc] key to open the Update window.
24. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
25.Press the [Esc] key twice to return to the standby display.

Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”


Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
FELCOM 18/19: [F8], [8], [6] to show the Export/Import window.

13
Save to FD Load from FD
1. ALL 1. ALL
2. Station List 2. Station List *: Availlable only in SSAS manager mode
3. LES List 3. LES List
("5.SSAS Report" is added in the SSAS
4. E-Mail Service List 4. E-Mail Service List
5. SSAS Report* 5. SSAS Report* manager mode and item numbers are shifted.)
6. Other 6. Other

FELCOM15/16
Export Import
1. Sent Message 1. Station List
2. Received Message 2. LES List
3. EGC Message 3. E-Mail/SMS Service List
4. Station List 4. Settings
5. LES List
6. E-Mail/SMS Service List
7. Test
8. Maintenance
9. Settings

FELCOM 18/19
Note 3: To confirm the settings, follow paragraph 3.5.

14
3.3 Transmitting SSAS Report
The SSAS report is sent one second after the button on the SSAS is pressed. Repeated
transmission can only be stopped from the SSAS manager mode.

1. Open the cover of the SSAS alert button.

Cover

2. Push the button one second. The button is a momentary switch, meaning it is activated
as soon as it is pressed one second.
3. The SSAS report is transmitted after the button is pushed one second. Below are the
contents of the SSAS report.

- - - SSAS ALERT MESSAGE - - -


Vessel Name: Queen Elizabeth 2 Ship's Name
MMSI: 111660000 MMSI No.
IMN: 443100000 IMN No.
Help me! Desired message
LAT: 34:44.46N Own ship postion in latitude
LON: 135:21.26E Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC) Time of course and speed data

FELCOM 15/16

- - - SSAS ALERT MESSAGE - - -


Vessel Name: Queen Elizabeth 2 Ship's Name
MMSI: 111660000 MMSI No.
IMN: 443100000 IMN No.
IMO: 123456789 IMO No.
Help me! Desired message
LAT: 34:44.46N Own ship postion in latitude
LON: 135:21.26E Own ship position in longitude
Time: 02/04/2004 04:31:48 (UTC) Time of position data
COURSE: 071 deg Course
SPEED: 00 kt Speed
Time: 02/04/2004 04:31:48 (UTC) Time of course and speed data

FELCOM 18/19

15
Note: If you accidentally push the button in, push it again within 30 seconds to cancel the report.
The button pops out ( ) and the report is not transmitted. When this is done, the message “INF:
SSAS UNIT activation has been canceled.” appears on the display. Additionally, for the
FELCOM 16/19, the POWER lamp on the communication unit flashes 30 seconds.
4. An LES sends acknowledgement to your ship.
5. For multiple destinations, steps 3 and 4 are automatically repeated (it is not necessary to
push the button again).

Cancelling repeated transmission


Terminal Unit: Turn off the communication unit. Press and hold down the button on the
SSAS unit while turning on the communication unit. Release the button when the test mode
starts. (The FELCOM 16/18/19 goes into the button test mode.) Note that if there are any
unsent messages they are sent and then the system goes into normal operation; namely,
the test mode is not activated.
PC: Open the SSAS manager (see page 12) and input the command TERMINATE SSAS
ALERT.

3.4 Testing the Button


The SSAS buttons can be tested as below.

Note 1: An actual SSAS report cannot be transmitted during the testing.


Note 2: The equipment must be in the SSAS manager mode to conduct the test.

FELCOM 15/18
1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key
FELCOM 18: [8] key
Operating mode is EGC receiver: [6] key
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.

16
Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
to escape.
Test
INF: Distress/SSAS
6. Test Buttons entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works
correctly.” appears if the unit is functioning properly.
7. Five seconds after pressing the button the SSAS test report is automatically sent to
station whose Mode set on the SSAS Report window is “Real+Test” or “Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appropriate button.
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

9. Press the [Esc] key three times to return to the standby display.

17
FELCOM 16/19, no PC

Turn off communication unit.

Turn on button of No. 1 SSAS.

Turn on communication unit.

30 s

POWER, LOGIN and TX lamps flash


in that order.

Send SSAS No (within 30 s)


test report?

Yes (after 30 s)
SSAS report is sent to station(s)
whose mode is "Real+Test" or "Test
Only". (See paragraph 3.2.)
Lamps flash rapidly during TX. It takes Test TX
2 to 5 minutes to send one message.

Test No ERROR lamp flashes rapidly.


successful?

Yes

POWER, LOGIN and TX lamps flash in


that order. ERROR lamp also flashes.

Turn off button of No. 1 SSAS.

The POWER, LOGIN and TX lamps flash


in that order.

Turn on button of No.2 SSAS.

Test TX

Turn off button of No.2 SSAS.

Note: If a 3rd SSAS unit is installed


test it by procedure used to test
Turn communication unit off and No.2 unit.
on again.

18
FELCOM 16/19, PC version
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu. For FELCOM 19, press the [8] key.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test

3. Press the [4] key.


Options
1. Login Test
2.1.Logout
PV Test SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select NCS
Self Test Start
5.4.Ocean Region
Distress Alarm Button Test
6. Test Yes No

4. Press the [Enter] key to start the test.


Options
1. Login Test
PV Test Distress/SSAS Button Test
2.1.Logout
3.2.Abort
PV Test Result
4.3.Select
Self NCS
Distress/SSAS
Test buttons are under test mode.
5.4.Ocean Region
Distress Press
Alarm any key
Button CAUTION
Testto escape.
INF: Distress/SSAS
6. Test Buttons entered into TEST MODE.

<Press ESC key to continue>

The display shows the message (in red) “SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button. The CAUTION window displays the message “SSAS UNIT works
correctly.” appears if the unit is functioning properly.
7. Five seconds after the button is pushed the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
Note: To test the No. 2 and No. 3 SSAS press appropriate button.
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.

<Press ESC key to continue>

9. Press the [Esc] key three times to return to the standby display.

19
3.5 SSAS Report Test
You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report message states “!!! Test Call !!!” to alert the
receiver of the message that it is a test call.

Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.

1. Press the [F5] key to open the Reports menu.


2. Press the [4] key to choose the SSAS Report menu.
3. Press the [1], [2], [3], [4] or [5] key as appropriate, and the SSAS report setting menu
appears.
4. Set destination where to transmit the test.
5. Press the [↑] key to choose Status and then press the [Enter] key.
6. Press the [↓] key to choose TEST and then press the [Enter] key.
7. Press the [Esc] key to open the Update window.
8. Yes is selected; press the [Enter] key. The test report is transmitted. After it is
transmitted, “Status” is automatically set to ON.
9. Press the [Esc] key twice to return to the standby display.

20
4. WATERPROOFING KIT
To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep
water splash out of the units.

Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward.
OP-xx (For IC-305)
Name Type Code No. Qty
Fixing Tape 24-009-1225 100-366-200-10 2

OP-xx (For IC-307)


Name Type Code No. Qty
Waterproofing Cover 16-023-5501 100-374-950-10 1
Fixing Tape 24-009-1225 100-366-200-10 2

1. Unfasten four screws to remove cover of IC-305/IC-307.


2. Attach supplied fixing to the underside of the cover as shown in the illustration below.
Fixing tape

3. Attach the cover.


4. For IC-307, remove the seal from the waterproofing cover and attach the cover as
shown in the illustration below.

21
D-1

6/Oct/2010 Y. NISHIYAMA
Y. Hatai
D-2
D-3

Mar.03'05
S-1
1 2 3 4 5 6

アンテナユニット
ANTENNA UNIT
IC-115
アラームユニットIC-306
ケーブル/コネクタは選択 ALARM UNIT
RW-4747 SELECT CABLE & CONNECTOR 16P0213D

TNCP-NJ
0.3m
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA ターミナルユニット 1 VCC
FBA-5DFB,0.4m 8D-FB-CV,50m,φ14.3: N-P-8DFB TERMINAL UNIT P
2 GND
5D-FB-CV,30m,φ10.7: N-P-5DFB IC-215 3 TD/RD-A
A P
4 TD/RD-B
*7 ANT DGPS *1 5 FG
TP5FBAW-5DFBB,30m,φ7.7 BNC PLUG COAX. CABLE(50Ω) DGPSデコーダー
DGPS DECODER
遭難警報器 IC-305 IC-350を接続するとき(IC-305との共用不可)
2B02 16P0208A DISTRESS ALERT/
*3 接続箱 RECEIVED CALL UNIT CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
Dsub15P JUNCTION BOX
KEYBOARD JUNCTION IC-315 *1 16P0213C
キーボード 1.6m 2m TTYCS-4 IC-315 *1
1 KDAT Vcc(ALM) 1 1 1 VCC 選択 INMARSAT No.1/2
KEYBOARD P
SELECT TTYCS-1
2 NC GND 2 2 2 GND 3 1 TR-A
2 TR-B アラームユニット
P
3 GND TD/RD-A 3 3 3 TD/RD-A 4
4 +5V TD/RD-B 4 4
P
4 TD/RD-B 3 FG ALARM UNIT
5 KCLK NC 5 5 5 FG IC-350 *2
6 NC TD-A 6 6
TD-B 7 7 TTYCS-1(*1) OR
CO-0.2x2P(*2) 航法装置 保安警報発呼器 保安警報発呼器 保安警報発呼器
船内LAN (HUB) RJ-45 LAN RD-A 8 8 NAV EQUIPMENT
STP CABLE(CAT5) *1 1 9 9 SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
パソコンなど PC: CROSS CABLE P
E_TD_P RD-B IC-307 (No.1) *2 *6 IC-307 (No.2) IC-307 (No.3)
2 10 10 TTYCS-4(*1) OR
LAN(HUB) OR PC, ETC. HUB: STRAIGHT CABLE E_TD-N GND
CO-0.2x5P(*2) *2 *6 *2 *6
3 E_RD_P DMC_OUT-H 11 11 1 SSAS_OUT-H 1 1
4 DMC_OUT-C 12 12 2 2 2
B P
5
NC
NC DMC_CHECK 13 13
P
3
NC
SSAS_CHECK
P
3
P
3
P P P
6 E_RD_N DMC_IN-C 14 14 4 SSAS_IN-C 4 4
7 NC DMC_CTRL 15 15 5 SSAS_CTRL 5 5
8 NC 6 GND 6 6

17JE-23090 *2 17JE-13090 最大3台まで接続可能。


*3 DTE -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) MAX.3 SETS AVAILABLE.
*3 17JE-23250 パソコン
プリンタ 57-3036 PRINTER CO-0.2x5P,MAX.15m TTYCS-4(*1) OR 合計 :最大200m
RH12BPG-3S 24VDC -02(D8C) 1 1 NC PC
VCTF-0.75x3C,5m,φ7 アカ RED 1 +24V PRINTER 1 1 2 2 CO-0.2x5P(*2) TOTAL: UP TO 200m
24 VDC RXD RXD
(16S0084) クロ BLK 2 0V PP-510 3 3
TXD TXD
16S0184,3m,φ8

シロ WHT 3 GND *2 4 4 DTR


36 25 GND 5 5 GND
6 6 DSR
*4 *4
7 7 RTS
8 8 CTS
9 9 NC
2B03 16P0209
FUSE *4 *4
15A(12V) *3
7A(24V) MJ-A3SPF 12-24VDC
12-24 VDC MJ-A3SPF0018-050ZC,5m,φ11 1 DC(+)
C シロ WHT
クロ BLK 2 DC(-) DTE 17JE-23090
-02(D8C)
3 GND 1 *2 FM14-7P
2 CO-0.2x2P,MAX.15m 1 EGCプリンタ
100-115/ 2B10 16P0214 RXD RXD
*1 TXD 3 2 TXD EGC PRINTER
200-230 VAC DPYC-2.5 08S0157,3m
1φ,50/60Hz AC AC/DC 24VDC + 4 3 0V PP-505 (+) 1 24VDC
*1 IN 銅板 *2
電源ユニット OUT - COPPER STRAP GND 5 (-) 2
24 VDC DPYC-4 + DC AC/DC POWER W=30,1.2m 6 7 NC
- IN GND
SUPPLY UNIT 7 *4 08S0087
E PR-240 *2 8
PE *1 9 FM14-7P *2 FM14-7P
IV-2sq. FM14-5P
CO-0.2x5P,MAX.100m
保護アース *4
1 RXD 1 1 RXD-H EGCプリンタ
2 TXD 2
P
2 TXD-H EGC PRINTER
3 NC 3
P
3 FG PP-505 *2 *5
4 NC 4 4 TXD-C
5 5 5 1 08S0157,3m
0V *2 RXD-C (+) 24VDC
*4 I/F BOX 6 6 +9V (-) 2
OP16-14 7 7 NC
注記 GND
*4 *4 08S0087
*1)造船所手配。
*2)オプション。
D *3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)TB基板(16P0116)が必要。
*6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。

NOTE DRAWN TITLE


*1. SHIPYARD SUPPLY. 20/Nov/2012 T.YAMASAKI FELCOM 15
CHECKED
*2. OPTION.
20/Nov/2012 T.TAKAHASHI
名称 インマルサットC船舶地球局
*3. FITTED AT FACTORY. APPROVED
*4. GROUND THRU CONNECTOR CLAMP. 20/Nov/2012 Y.NISHIYAMA 相互結線図
*5. TB BOARD (16P0116) REQUIRED. SCALE MASS NAME
*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 kg INMARSAT-C MES
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 DWG No.
*7. DO NOT SHORTEN ANTENNA CABLE. C5635-C01- T INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1 2 3 4

アンテナユニット
ANTENNA UNIT
IC-116 通信制御ユニット *3 *3
COMMUNICATION UNIT 17JE-13090 17JE-23090 パソコン
ケーブル/コネクタは選択 IC-216 DTE -02(D8C) *2 -02(D8C) PC
RW-4747 SELECT CABLE & CONNECTOR 1 17JE-573-10,5m,φ8 1 NC
0.3m TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA 2 2
FBA-5DFB,0.4m RXD RXD
A 8D-FB-CV,50m,φ14.3: N-P-8DFB TXD 3 3 TXD

TNCP-NJ
5D-FB-CV,30m,φ10.7: N-P-5DFB 4 4 DTR
*6 GND 5 5 GND
TP5FBAW-5DFBB,30m,φ7.7 ANT 6 6 DSR
TP58A15W-RG58,15m,φ5 7 7 RTS
8 8 CTS
9 9 NC
2B02 16P0208B

FUSE *3 接続箱 IC-315


SSAS D-sub15P JUNCTION BOX
10A:12VDC *3 *4
FM-C3FP 12-24VDC 2m
5A:24VDC Vcc(6.5V) 1 1 Vcc
12-24 VDC FM-C3FPS-002,3.5m,φ7.5 アカ RED 1 DC(+) GND 2 2 GND
クロ BLK 2 DC(-) TX/RX-A 3 3 TD/RD-A
3 GND TX/RX-B 4 4 TD/RD-B
NC 5 5 NC
2B10 16P0227
NC 6 6 TD-A
100-115/ *1
200-230 VAC DPYC-2.5 NC 7 7 TD-B
NC 8 8 RD-A 保安警報発呼器 保安警報発呼器 保安警報発呼器
1φ,50/60Hz ACAC/DC 24VDC + SSAS ALERT UNIT SSAS ALERT UNIT SSAS ALERT UNIT
B IN電源ユニット OUT - NC 9 9 RD-B
IC-307 (No.1) IC-307 (No.2) IC-307 (No.3)
*1 NC 10 10 GND *4
DPYC-4 AC/DC POWER *4 *5 *2 *5
24 VDC + DC SUPPLY UNIT SSAS_OUT-H 11 11 DMC_OUT-H 1 SSAS_OUT-H 1 1
- IN PR-240 *2 NC 12 12 DMC_OUT-C 2 NC 2 2
P P P
SSAS_CHECK 13 13 DMC_IN-H 3 SSAS_CHECK 3 3
PE *1 P P P
SSAS_IN-C 14 14 DMC_IN-C 4 SSAS_IN-C 4 4
IV-2sq. 5 5
保護アース SSAS_CTRL 15 15 DMC_CTR 5 SSAS_CTRL
6 GND 6 6
銅板 COPPER STRAP
W=30,1.2m 最大3台まで接続可能
MAX. 3 UNITS AVAILABLE
TTYCS-4(*1) OR CO-0.2x5P(*2)
合計:最大200m
TOTAL: UP TO 200m
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)SSAS仕様時標準支給。 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
C *5)終端のIC-307はジャンパー設定を変更する。
*6)アンテナケーブルは切断して使用しないこと。
DRAWN TITLE
30/Mar/2010 T.YAMASAKI FELCOM 16
NOTE
CHECKED 名称
*1. SHIPYARD SUPPLY. 30/Mar/2010 T.TAKAHASHI インマルサットMINI-C携帯移動地球局
*2. OPTION.
APPROVED
*3. FITTED AT FACTORY. 1/Apr/2010 Y.NISHIYAMA 相互結線図
*4. STANDARD SUPPLY FOR SSAS SPEC.
SCALE MASS NAME
*5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. kg INMARSAT MINI-C MES
S-2

*6. DO NOT SHORTEN ANTENNA CABLE.


DWG No.
C5638-C01- L INTERCONNECTION DIAGRAM

You might also like