0% found this document useful (0 votes)
74 views9 pages

Colable CAS System Configuration

The document provides instructions for configuring a Colable CAS (Conditional Access System). It describes: 1) Entering an 8-digit password when running the CAS for the first time. 2) Configuring database and scrambler settings such as IP addresses during initial CAS setup. 3) Setting communication ports and viewing status screens after configuration is complete. It also provides details on adding and setting parameters for individual scramblers, including setting AC numbers, output rates, and encryption status monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views9 pages

Colable CAS System Configuration

The document provides instructions for configuring a Colable CAS (Conditional Access System). It describes: 1) Entering an 8-digit password when running the CAS for the first time. 2) Configuring database and scrambler settings such as IP addresses during initial CAS setup. 3) Setting communication ports and viewing status screens after configuration is complete. It also provides details on adding and setting parameters for individual scramblers, including setting AC numbers, output rates, and encryption status monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 9

Colable CAS system configuration

Before run CAS system for the first time, it is necessary to input 8 digit PDK(user
password, it is 1-8 if Colable finished twice card encryption) as PICTURE 1-0, it only
can be set just one time and must be remembered. If re-install CAS system, it is
necessary to input the same password to run it.

PICTURE 1-0

Start CAS system as PICTURE 1-1, it will run successfully after simple setting.

PICTURE 1-1

1. Database configure: configure database IP which is the IP of the computer where


SQL server is running, input database sa password.
2. Scrambler Configure: do not set data_id, other setting should be in accordance
with the configuration of scrambler networking management software.
Select “fix emmg port”: set the same emmg port for all of the scramblers in the
network.
Unselect “fix emmg port”: as PICTURE 1-2, set scrambler IP and emmg port for
different scramblers in the scrambler network software.

PICTURE 1-2

3 SMS configure: set the communication port which should be the same as SMS
software setting
After finish all of the above setting, click “Save all”.
4 Scrambler status: display the status of the scramblers which connect to CA, as
PICTURE 1-3.

PICTURE 1-3
6 Operation log: display the operation record of the communication between SMS

1
and CA, as PICTURE 1-4.

PICTURE 1-4
7 Encrypt status: display the status of encrypting the programs in the scramblers,
as PICTURE 1-5.

PICTURE 1-5
Attention:
1> SQL server database system is necessary for PC to run CAS system.
2> It will take about 30 seconds to run CAS the first time in order to connect to
default database.
3> It will be better to restart CAS, if there is any change of the program in the

2
scrambler.

Scrambler setting explanation


The Scrambler is used for encrypting the input TS signals. Through the
Conditional Access System ( CAS ) , the authorized users can watch TV, Non-
authorized users can not, so that it provide a charge management system for the
system operators. We will emphatically introduce the software application and setting
of scrambler.

1、 Adding equipment:

open the software, select “Scrambler” on the equipment type list and right click
to add equipment, input the name (it would be better to name it according to number
or program packet in order to manage it conveniently) and IP address ( it must be the
same as IP address of hardware, please check IP address setting in the introduction of
“Network Connection”).

3
2、 Introduction of the interface:

① operation tool bar; ② the list of scramblers, display the quantity and names of
scramblers; ③ programs information from the selected scrambler; ④ the IP address,
total output stream rate, crypto period setting of selected scrambler; ⑤ equipment
running log bar; ⑥ scrambling channel and CAS setting; ⑦ communication state of
the ECMG and EMMG; ⑧ the AC number and PID value of ECM of the selected
program; ⑨ edit operation buttons.

3、 Parameters setting

(1) Scrambling setting: ① after connect to scrambler successfully, click “

4
” to refresh input program information; ②“ ” icon in front of the

scrambled programs; ③ “ ” icon in front of the programs which are not

scarmbled .

(2) Total output stream rate and crypto period setting: set the output stream rate

value according to the input stream rate (the input

stream rate can not be larger than output stream rate; it would be better to set output
stream rate 8-12Mbps larger than input stream rate because of empty packets stream);

set the crypto period .

(3) scrambling channel setting: choose the channel to run the CA, then set the
same port parameters as CA and IP address of the PC which runs CA, and so on;

means the scrambler will run the CA in CH2.

5
(4) Set the AC number of scrambler programs according to the parameters of AC
program groups in the SMS programs information setting.

(5) AC number setting of scrambler programs: click “ ”to enter the

interface ①; click “ ” to enter the interface ②; input AC Index “1” (natural

number) and AC Data “0101” (hexadecimal ), click “ ” to save setting; set all

6
the AC numbers (each scrambler input program has a exclusive AC number), the
interface ③ shows there are eight AC numbers for eight scrambler input program.

① ② ③

(6) Designate the AC number of each program.

(7) The icons are green when all the programs encryption are working
normally; the icons are red when the CA doesn’t run in this channel.

7
(8) Click “ ”to save current setting, click “ ”to save the

setting to the scrambler.