Colable CAS System Configuration
Colable CAS System Configuration
Before run CAS system for the first time, it is necessary to input 8 digit PDK(user
password, it is 1-8 if Colable finished twice card encryption) as PICTURE 1-0, it only
can be set just one time and must be remembered. If re-install CAS system, it is
necessary to input the same password to run it.
PICTURE 1-0
Start CAS system as PICTURE 1-1, it will run successfully after simple setting.
PICTURE 1-1
PICTURE 1-2
3 SMS configure: set the communication port which should be the same as SMS
software setting
After finish all of the above setting, click “Save all”.
4 Scrambler status: display the status of the scramblers which connect to CA, as
PICTURE 1-3.
PICTURE 1-3
6 Operation log: display the operation record of the communication between SMS
1
and CA, as PICTURE 1-4.
PICTURE 1-4
7 Encrypt status: display the status of encrypting the programs in the scramblers,
as PICTURE 1-5.
PICTURE 1-5
Attention:
1> SQL server database system is necessary for PC to run CAS system.
2> It will take about 30 seconds to run CAS the first time in order to connect to
default database.
3> It will be better to restart CAS, if there is any change of the program in the
2
scrambler.
1、 Adding equipment:
open the software, select “Scrambler” on the equipment type list and right click
to add equipment, input the name (it would be better to name it according to number
or program packet in order to manage it conveniently) and IP address ( it must be the
same as IP address of hardware, please check IP address setting in the introduction of
“Network Connection”).
3
2、 Introduction of the interface:
① operation tool bar; ② the list of scramblers, display the quantity and names of
scramblers; ③ programs information from the selected scrambler; ④ the IP address,
total output stream rate, crypto period setting of selected scrambler; ⑤ equipment
running log bar; ⑥ scrambling channel and CAS setting; ⑦ communication state of
the ECMG and EMMG; ⑧ the AC number and PID value of ECM of the selected
program; ⑨ edit operation buttons.
3、 Parameters setting
4
” to refresh input program information; ②“ ” icon in front of the
scarmbled .
(2) Total output stream rate and crypto period setting: set the output stream rate
stream rate can not be larger than output stream rate; it would be better to set output
stream rate 8-12Mbps larger than input stream rate because of empty packets stream);
(3) scrambling channel setting: choose the channel to run the CA, then set the
same port parameters as CA and IP address of the PC which runs CA, and so on;
5
(4) Set the AC number of scrambler programs according to the parameters of AC
program groups in the SMS programs information setting.
number) and AC Data “0101” (hexadecimal ), click “ ” to save setting; set all
6
the AC numbers (each scrambler input program has a exclusive AC number), the
interface ③ shows there are eight AC numbers for eight scrambler input program.
① ② ③
(7) The icons are green when all the programs encryption are working
normally; the icons are red when the CA doesn’t run in this channel.
7
(8) Click “ ”to save current setting, click “ ”to save the