Daikin VRV IV
Daikin VRV IV
High-COP type
Enables further energy saving
12HP - 50HP with 4 new models lineup
ENERGY
SAVING
VRV
COP 3.94 COP 4.39 11%
Increase
Standard type
Offers higher capacity of up to 60 HP
6 HP-60 HP with 3 new models lineup
UP TO
60 HP
VRV
COP 3.94 COP 3.99
Installation Space 1.66m2 1.42m2 14%
Decrease
HP
HP
Lineup
HP
High-COP Type
Standard Type
03
Energy saving
Higher Coefficient of Performance (COP)
COP at 100% operation load
Cooling Operation COP
4.32
Main Features
4.5
4.07
4 3.80 3.74
3.46
3.5 3.25
3
*Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
8 HP 10 HP 12 HP * 14 HP 16 HP 18 HP
6.83
7 6.45
6.02 5.92
6 5.47 5.13
5
4 *Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
8 HP 10 HP 12 HP * 14 HP 16 HP 18 HP
7 6.45
6 5.79
5.27
4.83
5
Capacity 4.07
priority 4.46 Energy saving priority
4 Fixed Refrigerant Variable Refrigerant Temperature
3 Temperature
*Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
100% 90% 80% * 70% 60% 50%
Load
04
Refined Design Meets Advanced
43%
Decrease
Installation space
As a leading global innovator, Daikin advanced from With this unbridled passion for high quality and
the conventional 2 module combination to a single advanced technology solutions, the new 20 HP is
module for 20 HP model. This allows the installation designed with the following considerations:
area to reduce by 43% as compared to the previous
VRV III 20 HP model.
Design considerations
1. Increase surface area of heat exchanger for 3. Sufficient cooling for electrical component
better performance 4. Eliminate suction resistance issue to enhance
2. Easy maintenance air flow volume.
VRV
Easy maintenance
Electrical component Electrical component
In previous VRV III design, the electrical component
is usually situated on the front surface which requires
the whole electrical component to be removed before
maintenance can be carried out.
05
Technologies
Main Features
The small holes created in the electric box are now close to the fan blower inlet, thus a significant pressure
difference can still be achieved unlike that of VRV III.
Electric box air
Positive pressure passage entrance Positive pressure
space ● Higher pressure space
as air entering is
near to the fan
Electric box air
blower inlet
passage outlet
High pressure
difference
Negative
Low pressure pressure Electric box air
Negative pressure
difference space passage outlet
space
VRV
Uneven Even
negative negative
pressure pressure
space space
VRV
06
VRT-Variable Refrigerant Temperature
power comsumption.
tor
Evapora
Indoor unit
heat exchanger
Typical changes in evaporating temperature and COP depending on changing indoor load
100%
Required capacity
Cooling load
& capacity
Automatic control to
inefficiencies occur.
adjust temperature
Low
Without VRT
Automatic control adjusts
20℃ 25℃ 30℃ 35℃ Outdoor evaporating temperature
Temp. to heat load change.
VRT
High
COP
Energy efficiency is
improved without
Low
Without VRT
sacrificing comfort.
07
New system more energy saving
Basic mode is selected to maintain optimal comfort.
VRT is selected to save energy and prevent excessive cooling.
Main Features
Capacity priority Energy saving priority
Fixed Refrigerant
Temperature
Variable Refrigerant Temperature
Floating Te Fixed Te
Start of Mild
cooling Quick • Gives priority to fast reaction speed.
Mode The refrigerant temperature goes down fast to keep the room setpoint stable.
Set temperature
25
Time • Gives priority to efficiency.
Very Fast Mild
Fast The refrigerant temperature goes down gradually giving priority to the
Mode
Medium efficiency of the system instead of the reaction speed.
35
VRT is particularly effective at night when
temperatures are low. 30
25
20
Av. min. temp.
15
(Typical example)
0
Mar. Jun. Sep. Dec.
08
More Flexible System Design
k
q
Max. actual
piping length 165m
First
indoor branch
p a f
Max. equivalent
piping length 190m First outdoor branch b
Single use
Actual Equivalent
piping length Example piping length
Refrigerant piping length 165 m a+f+g+h+i 190 m
Maximum Total piping length 1000 m a+b+c+d+e+f+g+h+i —
allowable
piping length Between the first indoor branch and the farthest indoor unit 90 m 1 f+g+h+i —
Between the outdoor branch and the last outdoor unit 10 m k+p 13 m
Level Example
Difference
Between the outdoor units (Multiple use) 5m q
Maximum Between the indoor units 30 m s
allowable
level difference Between the outdoor units If the outdoor unit is above. 90 m 2
r
and the indoor units If the outdoor unit is below. 90 m
2
r
1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. Various conditions and requirements have to be met
to allow utilisation of 90 m piping length. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.
2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting
on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.
50%–200% 200%
200%
Single outdoor units
09
For mixed combination of VRV and residential indoor units
Main Features
a b c d
VRV : VRV indoor unit
RA : Residential indoor unit e f g Max.
BP : BP unit First indoor branch
BP o
40 m
Max. Max.
h i m
50 m n BP 15 m
j
RA RA VRV
k
Max. RA VRV
l 15 m
RA
*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, connection ratio
must be 50% to 130%. Refer to page 34 for outdoor unit combination details.
10
Reliable and Stable System
Multiple advanced features ensuring more accurate test operation
and stable system
Efficient automatic test operation
Daikin VRV IV system incorporates a simplified and efficient test operation function, not only greatly
accelerating the installation process, but effectively improving the field setting quality as well.
Ease of installation
Compact & lightweight design
Highly-integrated VRV IV system offers compact
outdoor units to achieve maximum utilisation of the
installation space.
765 765
1,240 mm mm 930 mm mm
VRV 12 HP 12 HP
11
Simplified commissioning and after-sales service
Main Features
Figures out
system
operation information, enabling the operation
Displays
operational state to be visually system
information by
reading light
displayed whilst facilitating simplified operation
emitting state of
information
commissioning and after-sales service. directly
different diodes,
which is both
inefficient and
fallible.
VRV configurator
The VRV configurator is an advanced
software solution that allows for easy
system configuration and commissioning.
Automatic Automatic
sequencing sequencing
12
Outdoor Unit Lineup
Outdoor Units
High-COP Type
Double Outdoor Units Triple Outdoor Units
12, 14, 16 HP 18, 20, 22, 24, 26, 28, 30, 32 HP 34, 38 HP
Standard Type
Single Outdoor Units Double Outdoor Units
6, 8, 10, 12 HP 14, 16 HP 18, 20 HP 22, 24, 26 HP 28, 30, 32 HP
Model name ending with ~YM for ASEAN, ~Y14 for Indonesia, ~Y1S for Thailand
17
Cooling Only
Lineup
HP
High-COP Type
Standard Type
18
Indoor Unit Lineup
Indoor units can be selected from 2 lineups, both VRV and residential indoor units,
to match rooms and preferences.
VRV indoor units 22 types 108 models
FXDQ-PBVE
(with drain pump)
FXDQ-PBVET
Slim Ceiling Mounted Duct (without drain pump)
FXDQ-NBVE
(with drain pump)
FXDQ-NBVET
(without drain pump)
FXMQ-PVE
Ceiling Mounted Duct
FXMQ-MAVE
FXVQ-NY1
Floor Standing Duct
FXVQ-NY16
(high static pressure type)
19
Residential indoor units with connection to BP units 6 types 18 models
25 35 50 60 71
Type Model Name Rated Capacity 2.5 kW 3.5 kW 5.0 kW 6.0 kW 7.1 kW
Capacity Index 25 35 50 60 71
FDKS-EAVMB
(700 mm width type)
Slim Ceiling
Mounted Duct
FDKS-C(A)VMB
(900/1,100 mm width type)
FTKJ-NVMW
FTKJ-NVMS
FTKS-BVMA
FTKS-FVM
Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXQ6-20TA) can be connected.
Max.
VRV indoor units
64 indoor
units
BP unit BP unit
Max.
32 indoor
units
Residential indoor units
20
Indoor Unit Lineup
Daikin offers a wide range of indoor units includes both VRV and residential
models responding to variety of needs of our customers that require
air-conditioning solutions.
VRV Indoor
VRV Indoor Units
Units
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Round Flow with Sensing) Type (Round Flow) Type
FXFQ-SVM FXFQ-LUV1
Quiet, compact, and designed for Thin, lightweight, and easy to install in
user comfort narrow ceiling spaces
FXDQ-NBVE(T)
FXDQ-SPV1 FXSQ-PVE
Slim and compact design for easy and Middle external static pressure
flexible installation and slim design allow flexible installations
21
Ceiling Mounted Duct Type Outdoor-Air
Processing Unit
FXMQ-PVE
FXMQ-MFV1
FXMQ-MAVE
Combine fresh air treatment
High external static pressure and air conditioning,
allows flexible installations supplied from a single system.
FXUQ-AVEB
FXVQ-NY16
(high static pressure type)
FTKS-BVMA
FDKS-C(A)VMB FTKJ-NVMS
FTKS-FVM
Slim and smooth design suits Elegant appearance with Stylish flat panel harmonises
your shallow ceiling European style with your interior décor
22