Daikin VRV IV

The document discusses enhancements to a company's VRV lineup, which now includes three types - high-COP, standard, and space saving. The high-COP type enables further energy savings with new smaller models. The standard type offers higher capacities up to 60HP. The space saving type has a compact, lightweight design. The 20HP model was redesigned as a single module to reduce installation space by 43%. Key design considerations included increasing heat exchanger surface area and sufficient cooling for electrical components while eliminating suction resistance issues.

Uploaded by

Javaid Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
314 views36 pages

Daikin VRV IV

The document discusses enhancements to a company's VRV lineup, which now includes three types - high-COP, standard, and space saving. The high-COP type enables further energy savings with new smaller models. The standard type offers higher capacities up to 60HP. The space saving type has a compact, lightweight design. The 20HP model was redesigned as a single module to reduce installation space by 43%. Key design considerations included increasing heat exchanger surface area and sufficient cooling for electrical components while eliminating suction resistance issues.

Uploaded by

Javaid Ashraf
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Excellent Operation Performance

Enhanced Lineup to 3 types

High-COP type
Enables further energy saving
12HP - 50HP with 4 new models lineup
ENERGY
SAVING
VRV
COP 3.94 COP 4.39 11%
Increase

Installation Space 1.66m2 2.13m2

Product Weight 490kg 555kg


20
HP

Standard type
Offers higher capacity of up to 60 HP
6 HP-60 HP with 3 new models lineup
UP TO
60 HP
VRV
COP 3.94 COP 3.99
Installation Space 1.66m2 1.42m2 14%
Decrease

Product Weight 490kg 380kg 22%


20 Decrease

HP

Space Saving type


New series with compact & lightweight design
18 HP-50 HP with 17 new models lineup
COMPACT
DESIGN
VRV
COP 3.94 COP 3.11
Installation Space 1.66m 2
0.95m2 43%
Decrease

Product Weight 490kg 320kg 35%


20 Decrease

HP

Lineup

HP
High-COP Type

Standard Type

Space Saving Type

03
Energy saving
Higher Coefficient of Performance (COP)
COP at 100% operation load
Cooling Operation COP

4.32

Main Features
4.5
4.07
4 3.80 3.74
3.46
3.5 3.25
3
*Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
8 HP 10 HP 12 HP * 14 HP 16 HP 18 HP

Higher Coefficient of Performance (COP)


COP at 50% operation load
Cooling Operation COP

6.83
7 6.45
6.02 5.92
6 5.47 5.13
5
4 *Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
8 HP 10 HP 12 HP * 14 HP 16 HP 18 HP

Higher Coefficient of Performance (COP)


COP for 10 HP
Cooling Operation COP

7 6.45
6 5.79
5.27
4.83
5
Capacity 4.07
priority 4.46 Energy saving priority
4 Fixed Refrigerant Variable Refrigerant Temperature
3 Temperature
*Cooling operation conditions: Indoor temp. of
0 27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
100% 90% 80% * 70% 60% 50%
Load

04
Refined Design Meets Advanced

Realising compact technology with performance

43%
Decrease
Installation space

VRV 20HP 20HP

As a leading global innovator, Daikin advanced from With this unbridled passion for high quality and
the conventional 2 module combination to a single advanced technology solutions, the new 20 HP is
module for 20 HP model. This allows the installation designed with the following considerations:
area to reduce by 43% as compared to the previous
VRV III 20 HP model.
Design considerations
1. Increase surface area of heat exchanger for 3. Sufficient cooling for electrical component
better performance 4. Eliminate suction resistance issue to enhance
2. Easy maintenance air flow volume.

Increase surface area of heat exchanger


The unique 4-sided all round heat exchanger ensure
sufficient surface area for the heat exchanger as
oppose to conventional 3-sided heat exchanger. This
improves the heat exchanger performance without
increasing the footprint.

VRV

Easy maintenance
Electrical component Electrical component
In previous VRV III design, the electrical component
is usually situated on the front surface which requires
the whole electrical component to be removed before
maintenance can be carried out.

With the new design, the electrical component is


strategically located on the top which ease the
maintenance process.

Moreover, the heat exchanger on the front side can


be extended to take up the previous space used for
the electrical component and improve its
performance. VRV

05
Technologies

Sufficient cooling for electrical component


The new 20 HP model is designed with the electrical box strategically located between a region of positive and
negative pressure. This design allows a larger air flow from negative pressure to positive pressure due to the
higher pressure difference.

Main Features
The small holes created in the electric box are now close to the fan blower inlet, thus a significant pressure
difference can still be achieved unlike that of VRV III.
Electric box air
Positive pressure passage entrance Positive pressure
space ● Higher pressure space
as air entering is
near to the fan
Electric box air
blower inlet
passage outlet
High pressure
difference

Negative
Low pressure pressure Electric box air
Negative pressure
difference space passage outlet
space

Electric box air


passage entrance
● Pressure is lower
as the area where
air enters is far away
from the fan blower
inlet

VRV

Eliminate suction resistance issue


Without affecting the fan volume, the electric component is re-designed to the top and free up the dead space
that existed in previous VRV III models. This eliminates the problem of suction resistance.

Uneven Even
negative negative
pressure pressure
space space

VRV

06
VRT-Variable Refrigerant Temperature

State-of-the-art energy saving technology for VRV system

Customise your VRV for optimal annual efficiency


The new VRV IV system now features VRT technology. Refrigerant cycle
VRT automatically adjusts refrigerant temperature to (During cooling)
individual building and climate requirement, thus further
improving annual energy efficiency and maintaining comfort.
With this excellent technology, running costs are reduced. er
Condens

How is energy reduced?


During cooling, the refrigerant evaporating temperature (Te)
is raised to minimise the difference with the condensing
temperature.Compressors work less, and this reduces Compressor

power comsumption.
tor
Evapora
Indoor unit
heat exchanger

Evaporating temperature raised


Compressor workload reduced

Typical changes in evaporating temperature and COP depending on changing indoor load

100%

Required capacity
Cooling load
& capacity

Capacity changes as air


changes
to match conditioning load changes
heat load according to outdoor
temperature.
25%

20℃ 25℃ 30℃ 35℃ Outdoor


Temp.
In case of fixed
evaporating temperature,
excessive cooling, thermo
Refrigerant evaporating

on-off loss, and other


VRT
High
temp. / Te(℃)

Automatic control to
inefficiencies occur.
adjust temperature
Low

Without VRT
Automatic control adjusts
20℃ 25℃ 30℃ 35℃ Outdoor evaporating temperature
Temp. to heat load change.

VRT
High
COP

Energy efficiency is
improved without
Low

Without VRT
sacrificing comfort.

20℃ 25℃ 30℃ 35℃ Outdoor


Temp.

07
New system more energy saving
Basic mode is selected to maintain optimal comfort.
VRT is selected to save energy and prevent excessive cooling.

Main Features
Capacity priority Energy saving priority
Fixed Refrigerant
Temperature
Variable Refrigerant Temperature

Basic Mode Auto Mode High Sensible


Fixed Te - Standard control Floating target Te depending on heat load Mode
(default setting on VRV IV) Fixed target Te

Selecting VRT enables operation to be optimised for


either energy efficiency or rapid cooling.

Floating Te Fixed Te

Powerful Mode Quick Mode Mild Mode Eco Mode


Reaction speed VERY FAST Reaction speed FAST Reaction speed MEDIUM Unable to change Te
(Default setting VRV IV)

VRT offers quicker cool down


to shorten uncomfortable pull down time. • Can boost capacity above 100% if needed.
Powerful The refrigerant temperature can go lower in cooling than the set minimum.
30 Mode • Gives priority to very fast reaction speed.
Powerful The refrigerant temperature goes down fast to keep the room setpoint stable.
Quick
Indoor Temp. (ºC)

Start of Mild
cooling Quick • Gives priority to fast reaction speed.
Mode The refrigerant temperature goes down fast to keep the room setpoint stable.

Set temperature
25
Time • Gives priority to efficiency.
Very Fast Mild
Fast The refrigerant temperature goes down gradually giving priority to the
Mode
Medium efficiency of the system instead of the reaction speed.

Recommended for use in these situations


Cooling only regions having differences
in daily temperature. 40
Av. max. temp. Av. daily temp. difference
Outdoor Temp. (ºC)

35
VRT is particularly effective at night when
temperatures are low. 30
25
20
Av. min. temp.
15
(Typical example)
0
Mar. Jun. Sep. Dec.

08
More Flexible System Design

More options for installation location

Long piping length


The long piping length provides more design flexibility, which can match even large-sized buildings.
Multiple use

For connection of only VRV indoor units

k
q
Max. actual
piping length 165m
First
indoor branch

p a f
Max. equivalent
piping length 190m First outdoor branch b
Single use

*The rest of indoor units are


the same as for single use.
Max. total
piping length 1000m a
f g h
b c d e i
First indoor branch

Max. level difference


between the outdoor units 90m r Max.
and the indoor units
90 m 2
Max.
s
30 m
Max. level difference
between the indoor units 30m 15 m higher
than VRV Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

Actual Equivalent
piping length Example piping length
Refrigerant piping length 165 m a+f+g+h+i 190 m
Maximum Total piping length 1000 m a+b+c+d+e+f+g+h+i —
allowable
piping length Between the first indoor branch and the farthest indoor unit 90 m 1 f+g+h+i —

Between the outdoor branch and the last outdoor unit 10 m k+p 13 m

Level Example
Difference
Between the outdoor units (Multiple use) 5m q
Maximum Between the indoor units 30 m s
allowable
level difference Between the outdoor units If the outdoor unit is above. 90 m 2
r
and the indoor units If the outdoor unit is below. 90 m
2
r

1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. Various conditions and requirements have to be met
to allow utilisation of 90 m piping length. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.
2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting
on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.

Connection ratio Conditions of VRV indoor unit connection capacity

Connection capacity at maximum is 200%.


Applicable Other VRV indoor
VRV indoor units unit models*1
Connection ratio FXDQ, FXSQ, FXMQ-P, FXAQ models

50%–200% 200%

200%
Single outdoor units

Double outdoor units 160%


Connection ratio = Triple outdoor units 130%
Total capacity index of the indoor units *1 For the FXFQ25LU,FXFQ-S and FXVQ models, maximum connection ratio is 130% for the
entire range of outdoor units.
Capacity index of the outdoor units If the operational capacity of indoor units is more than 130%, low airflow operation is
enforced in all the indoor units.
*Refer to page 33-34 for outdoor unit combination details.

09
For mixed combination of VRV and residential indoor units

Colours in the diagram below are merely for identifying


pipes referenced with symbols such as a .

Main Features
a b c d
VRV : VRV indoor unit
RA : Residential indoor unit e f g Max.
BP : BP unit First indoor branch
BP o
40 m
Max. Max.
h i m
50 m n BP 15 m
j
RA RA VRV
k
Max. RA VRV
l 15 m
RA

When a mixed combination of VRV and residential indoor units is connected


or when only residential indoor units are connected Actual piping length Example
Refrigerant piping length 100 m a+b+c+g+k, a+b+c+d
Total piping length 250 m a+b+c+d+e+f+g+h+i+j+k

Maximum allowable If indoor unit capacity index < 60. 2 m–15 m


piping length Between BP unit
If indoor unit capacity index is 60. 2 m–12 m h, i, j, k
and indoor unit
If indoor unit capacity index is 71. 2 m–8 m
Between the first indoor branch and the farthest BP unit or
50 m*1 b+c+g, b+c+d
between the first indoor branch and the farthest VRV indoor unit
Minimum allowable piping length Between outdoor unit and the first indoor branch 5m a

Level Difference Example


Between the indoor units 15 m l
Between BP units 15 m m
Maximum allowable
Between the outdoor unit If the outdoor unit is above. 50 m n
level difference
and the indoor unit If the outdoor unit is below. 40 m n
Between the outdoor unit and the BP unit 40 m o
*1. When the piping length exceeds 20 m, the size of the main pipes (the gas side and the liquid side) must be increased. Please refer to Engineering
Data Book for details.

*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, connection ratio
must be 50% to 130%. Refer to page 34 for outdoor unit combination details.

High external static pressure


VRV IV outdoor unit has been achieved high
external static pressure up to 78.4 Pa,
ensuring the efficient heat dissipation and
78.4 Pa
stable operation of equipment in either
hierarchical or intensive arrangement. More options in the
opening/angle of louvre
Outstanding heat dissipation
effect in both hierarchical and
intensive arrangement

10
Reliable and Stable System
Multiple advanced features ensuring more accurate test operation
and stable system
Efficient automatic test operation
Daikin VRV IV system incorporates a simplified and efficient test operation function, not only greatly
accelerating the installation process, but effectively improving the field setting quality as well.

Automatically checks the wirings


Automatic check WIRING between outdoor units and indoor
CHECK units to confirm whether there is a
defective wiring.

Confirms and corrects the actual


PIPING
piping length.
CHECK

Automatically check whether the


STOP stop valve in each outdoor unit is in
VALVE normal status to ensure the smooth
CHECK operation of air conditioning system.

Ease of installation
Compact & lightweight design
Highly-integrated VRV IV system offers compact
outdoor units to achieve maximum utilisation of the
installation space.

765 765
1,240 mm mm 930 mm mm

VRV 12 HP 12 HP

Installation Space 0.95 m2 0.71 m2 25%


Decrease

Product Weight 285 kg 195 kg 32%


32 % Decrease
Decrease

11
Simplified commissioning and after-sales service

Function of information display


by luminous digital tube Conventional LED display 7-segment digital display

VRV IV system utilises 7-segment


luminous digital tubes to display system

Main Features
Figures out
system
operation information, enabling the operation
Displays
operational state to be visually system
information by
reading light
displayed whilst facilitating simplified operation
emitting state of
information
commissioning and after-sales service. directly
different diodes,
which is both
inefficient and
fallible.

VRV configurator
The VRV configurator is an advanced
software solution that allows for easy
system configuration and commissioning.

Less time is required on the roof Simplified commissioning


configuring the outdoor unit.

Multiple systems at different sites can


be managed in exactly the same way,
thus offering simplified commissioning
for key accounts. Retrieve initial system settings

Initial settings on the outdoor unit can be


easily retrieved.

Outdoor unit sequencing technology


Automatic sequencing operation
During start-up, Daikin VRV IV unit sequencing operation will be automatically enabled to ensure balanced
operation of each outdoor unit to improve longevity of equipment and stable operation.

Stage 1 Stage 2 Stage 3

Automatic Automatic
sequencing sequencing

Priority: Priority: Priority:

12
Outdoor Unit Lineup

Outdoor Units

The outdoor unit capacity is up to 60 HP in increment of 2 HP.


VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing
the system flexibility to a new level.
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.

High-COP Type
Double Outdoor Units Triple Outdoor Units
12, 14, 16 HP 18, 20, 22, 24, 26, 28, 30, 32 HP 34, 38 HP

RXQ12TAH RXQ18TAH RXQ24TAH RXQ30TAH


RXQ20TAH RXQ26TAH RXQ32TAH RXQ34TAH
RXQ14TAH
RXQ22TAH RXQ28TAH RXQ38TAH
RXQ16TAH

Standard Type
Single Outdoor Units Double Outdoor Units
6, 8, 10, 12 HP 14, 16 HP 18, 20 HP 22, 24, 26 HP 28, 30, 32 HP

RXQ6TA RXQ14TA RXQ18TAN RXQ22TAN RXQ28TAN


RXQ8TA RXQ16TA RXQ20TAN RXQ24TAN RXQ30TAN
RXQ10TA RXQ26TAN RXQ32TAN
RXQ12TA

Space Saving Type


Single Outdoor Units Double Outdoor Units
18, 20 HP 22, 24 HP 26, 28, 30, 32 HP

RXQ18TA RXQ22TAS RXQ26TAS RXQ30TAS


RXQ20TA RXQ24TAS RXQ28TAS RXQ32TAS

Model name ending with ~YM for ASEAN, ~Y14 for Indonesia, ~Y1S for Thailand

17
Cooling Only

Lineup
HP

High-COP Type

Standard Type

Space Saving Type

Outdoor Unit Lineup


36, 40 HP 42, 44, 46, 48, 50 HP

RXQ36TAH RXQ42TAH RXQ48TAH


RXQ40TAH RXQ44TAH RXQ50TAH
RXQ46TAH

Triple Outdoor Units


34, 36 HP 38, 40 HP 42, 44 HP 46, 48, 50, 52, 54, 56, 58, 60 HP

RXQ34TAN RXQ38TAN RXQ42TAN RXQ46TAN RXQ54TAN


RXQ36TAN RXQ40TAN RXQ44TAN RXQ48TAN RXQ56TAN
RXQ50TAN RXQ58TAN
RXQ52TAN RXQ60TAN

Double Outdoor Units Triple Outdoor Units


34, 36, 38, 40 HP 42, 44 HP 46, 48, 50 HP

RXQ34TAS RXQ38TAS RXQ42TAS RXQ46TAS


RXQ36TAS RXQ40TAS RXQ44TAS RXQ48TAS
RXQ50TAS

18
Indoor Unit Lineup

Enhanced range of choices

Indoor units can be selected from 2 lineups, both VRV and residential indoor units,
to match rooms and preferences.
VRV indoor units 22 types 108 models

Type Model Name Capacity Range


Capacity Index

Ceiling Mounted Cassette


(Round Flow with Sensing) FXFQ-SVM

Ceiling Mounted Cassette


FXFQ-LUV1
(Round Flow)

Ceiling Mounted Cassette


(Compact Multi Flow)
FXZQ-MVE

Ceiling Mounted Cassette


(Double Flow)
FXCQ-MVE

Ceiling Mounted Cassette


Corner FXKQ-MAVE

FXDQ-PBVE
(with drain pump)

FXDQ-PBVET
Slim Ceiling Mounted Duct (without drain pump)

FXDQ-NBVE
(with drain pump)

FXDQ-NBVET
(without drain pump)

Slim Ceiling Mounted Duct FXDQ-SPV1


(Compact Series)

Middle Static Pressure FXSQ-PVE


Ceiling Mounted Duct

FXMQ-PVE
Ceiling Mounted Duct

FXMQ-MAVE

Outdoor-Air Processing Unit FXMQ-MFV1

4-Way Flow Ceiling Suspended FXUQ-AVEB

Ceiling Suspended FXHQ-MAVE

Wall Mounted FXAQ-PVE

Floor Standing FXLQ-MAVE

Concealed Floor Standing FXNQ-MAVE

FXVQ-NY1
Floor Standing Duct
FXVQ-NY16
(high static pressure type)

Air Handling Unit AHUR 6 - 120HP

Daikin air handing units can be connected to VRV IV system.

19
Residential indoor units with connection to BP units 6 types 18 models
25 35 50 60 71
Type Model Name Rated Capacity 2.5 kW 3.5 kW 5.0 kW 6.0 kW 7.1 kW
Capacity Index 25 35 50 60 71

FDKS-EAVMB
(700 mm width type)
Slim Ceiling
Mounted Duct
FDKS-C(A)VMB
(900/1,100 mm width type)

FTKJ-NVMW

FTKJ-NVMS

Indoor Unit Lineup


Wall Mounted FTKS-DVM

FTKS-BVMA

FTKS-FVM

Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXQ6-20TA) can be connected.

Max.
VRV indoor units
64 indoor
units

BP unit BP unit

Max.
32 indoor
units
Residential indoor units

20
Indoor Unit Lineup

Daikin offers a wide range of indoor units includes both VRV and residential
models responding to variety of needs of our customers that require
air-conditioning solutions.

VRV Indoor
VRV Indoor Units
Units
Ceiling Mounted Cassette Ceiling Mounted Cassette
(Round Flow with Sensing) Type (Round Flow) Type
FXFQ-SVM FXFQ-LUV1

Presence of people and floor 360 airflow improves temperature


temperature can be detected to distribution and offers a comfortable
provide comfort and energy savings living environment.

Ceiling Mounted Cassette Ceiling Mounted Cassette


(Compact Multi Flow) Type (Double Flow) Type
FXZQ-MVE FXCQ-MVE

Quiet, compact, and designed for Thin, lightweight, and easy to install in
user comfort narrow ceiling spaces

Ceiling Mounted Cassette Slim Ceiling Mounted Duct Type


Corner Type (Standard Series)
FXKQ-MAVE FXDQ-PBVE(T)

FXDQ-NBVE(T)

Slim design for flexible installation Slim design, quietness and


static pressure switching

Slim Ceiling Mounted Duct Type Middle Static Pressure Ceiling


(Compact Series) Mounted Duct Type

FXDQ-SPV1 FXSQ-PVE

Slim and compact design for easy and Middle external static pressure
flexible installation and slim design allow flexible installations

21
Ceiling Mounted Duct Type Outdoor-Air
Processing Unit
FXMQ-PVE
FXMQ-MFV1

FXMQ-MAVE
Combine fresh air treatment
High external static pressure and air conditioning,
allows flexible installations supplied from a single system.

Ceiling Suspended Type


4-Way Flow Ceiling
Suspended Type FXHQ-MAVE

FXUQ-AVEB

This slim and stylish indoor unit


achieves optimum air distribution,
and can be installed without the
Slim body with quiet and wide airflow

Indoor Unit Lineup


need for ceiling cavity

Wall Mounted Type Floor Standing Type


FXAQ-PVE FXLQ-MAVE

Concealed Floor Standing Type


FXNQ-MAVE
Stylish flat panel design
harmonised with your interior Suitable for perimeter zone air
décor conditioning

Floor Standing Duct Type Air Handling Unit


FXVQ-NY1 AHUR

FXVQ-NY16
(high static pressure type)

Integrate your air handling unit in a total


Large airfiow type for large spaces. solution for large size spaces such as
Flexible interior design for each tenant. factories and large stores.

Residential Indoor Units with connection to BP units


Slim Ceiling Mounted Duct Type Wall Mounted Type Wall Mounted Type
FDKS-EAVMB FTKJ-NVMW FTKS-DVM

FTKS-BVMA
FDKS-C(A)VMB FTKJ-NVMS

FTKS-FVM
Slim and smooth design suits Elegant appearance with Stylish flat panel harmonises
your shallow ceiling European style with your interior décor

22