DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (GAS DETECTOR)
Page 5 of 14
ITEM DESCRIPTION
1 Tag Number See list below
2 Service See list below
3 Drawing Number See list below
GENERAL
40 Model VTA
41 Serial Number VTA
42
43
NOTE :
1 Vendor to furnish mounting bracket, calibration /interrogation tool.
2 Gas detector shall immune to RF interference, solar radiation, lighting, arc welding, and other source of radiation sudden tempersture change, etc
shall not affect to the operation of gas detector or provide common alarm.
3 The detector shall meet SIL 2 certified according to IEC 61508.
4 Vendor to advise (VTA).
5 Vendor to provide 316 SS name pate. The tag plate shall consist of information such as Tag Number, Services, Date of Manufacture, etc.
6 The Vendor shall guarantee the full compatibility and good functionality of their detectors with the selected FGS System.
7 Refer to Specification for Fire and Gas Detector (PEL-00-INS-SPC-003).
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (SMOKE DETECTOR)
Page 6 of 14
ITEM DESCRIPTION
1 Tag Number See list below
GENERAL
Immune from Radio frequency, solar radiation, arc welding , lightning, electromagnetic
12 Immunity
interference and the like or Per Manufacturer Standard for UL/FM Approval Certification
The ionization chamber ionizes smoke particle in the chamber. It result in current that reflect
13 Detection principle
contain of the air (there was smoke or not)
SMOKE DETECTOR
14 Integral Alarm indication Red LED, LED remain illuminated until the Alarm condition has been reset
15 Supply wiring Two wire monitored supply
16 Detector/ Base connection B501BP
17 Cable entry 1/2 NPT (Note 4)
18
19 Tag Plate 316 SS material
Containing terminal for wiring, Blak box c/w base, screws, unit, etc suitable for surface mounting,
20 Electrical wiring Box
terminals: nickel plated Stainless Steel.
OPTIONS
21 End of line device Suitable for use with input module monitoring short and open circuit fault for specified tags
22 Test Kit One set of smoke detector aerosol provided to allow testing of the detectors
23 Filter Provided for each smoke detector to prevent small insect entering detector chamber
24 Intelligent Base Yes
25 Mounting Surface
26 Manufacturer Vendor List
27 Model Note 4
PURCHASE
NOTE :
1. Test Kit (Telescopic pole, smoke dispenser, smoke tester) and detector removal tools supplied by vendor.
2. Detecor compatible with Fire Alarm Panel.
3. Certified plug for the spare entries provided by vendor.
4. VTA (Vendor to Advise)
LIST :
No Tag Number Services Drawing Number
1 SD-PS001 Control Room PEL-00-INS-DW-011
2 SD-PS002 Battery Room PEL-00-INS-DW-011
3 SD-PS003 Electrical Room PEL-00-INS-DW-011
4 SD-PS004 Marshalling Room PEL-00-INS-DW-011
PEKERJAAN PEMBANGUNAN PEMASANGAN JALUR PIPA GAS DARI
BENOA KE PLTG PESANGGARAN - BALI
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (SMOKE DETECTOR)
Page 6 of 14
PEKERJAAN PEMBANGUNAN PEMASANGAN JALUR PIPA GAS
DARI BENOA KE PLTG PESANGGARAN - BALI
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (HEAT DETECTOR)
Page 7 of 14
ITEM DESCRIPTION
1 Tag Number See List
2 Service See List
GENERAL
16 Certifification UL listed
17 Auto reset Yes, provided
18
19 Mounting Base Inteligent Mounting base compatible with Alarm Panel
ACCESSORIES /
21 Manufacturer VTA
22 Model VTA
23 Mounting Surface
24
25
26 Manufacturer Vendor List
27 Model Note 6
PURCHASE
Note :
1 Test Kit (Telescopic pole, smoke dispenser, smoke tester) and detector removal tools supplied by vendor.
2 Applicable Specification for Fire and Gas Detector (PEL-00-INS-SPC-003)
3 Detector have been compatible with Fire Alarm Panel.
4 LED for Alarm condition remain illuminated until the alarm condition has been reset.
5 The proper material suitable for indoor/room environment confirmed by vendor.
6 VTA (Vendor to Advise)
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (HEAT DETECTOR)
Page 7 of 14
PEKERJAAN PEMBANGUNAN PEMASANGAN JALUR PIPA GAS DARI
BENOA KE PLTG PESANGGARAN - BALI
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (FLAME DETECTOR)
Page 8 of 14
ITEM DESCRIPTION
1 Tag Number See List
2 Quantity 2 Ea
3 Service See List
GENERAL
Fault: 0-0.2 mA, Test mode: 1.5 mA, COPM Fault: 2 mA, Normal: 4.3 mA
18 Alarms
Warn: 16 mA, Alarm: 20 mA (± 0.2 mA)
Radio Frequency and False Alarm Immune from Radio frequency, solar radiation, arc welding and lightning, maximum
19
Immunity false alarm rejection
20 Monitoring Remote F&G system (By others)
21 Status indicator LED
22 No of wires 3 wire system
23 Cable type and Cores 16 AWG Twisted - shielded pair
24 Cable Entry 3/4 inch NPT (Note 3,4)
25 Terminal Box Yes
26 Surge protection Yes
27 Power consumption 20-36 VDC
28 Enclosure Weather proof: IP 65,Explosion proof : Ex (d) Zone 1, IIA ,T3
Include Ni Cad Battery, Charger, Low Level Handle, Extension Pole, and spare bulb
29 Test Kit
ACCESSORIES /
with battery
OPTIONS
Note :
1. Vendor supplied calibrating IR Touch / source.
2. Applicable Specification for Fire and Gas Detector (PEL-00-INS-SPC-003)
3. Spare entries provided with certified plugs.
4. Vedor to complete verify or specify.
5. The Sensitivity shall not effect by arc welding, lightning, sunlight, artificial light or heated object.
6. Detector shall have capability of detecting fire through surface level lens contamination e.g. dust, oil, or water spray.
Date
DATASHEET FOR
PEL-00-INS-DS-010 REV. 1 10/19/2015
FIRE AND GAS SYSTEM (FLAME DETECTOR)
Page 8 of 14
JASA KONSULTASI ENGINEERING
FRONT END ENGINEERING DESIGN (FEED) PROYEK
PEMBANGUNAN FASILITAS CBM DAN PIPELINE DI TBBM
AMPENAN
No. Dokumen :
Halaman 4 dari 5
AMP-DS-40-005-A4
DAFTAR ISI
No. Dokumen :
Halaman 5 dari 5
AMP-DS-40-005-A4
Note :
(*) Vedor to Advise/Verify.
1. Manufacture shall presented in vendor list Company Approval.
2. A316 SS name plate have permanently attached. The name plate show the tag number, range, serial number and
year of manufacturer as a minimum.