Design For 3-Pile Group

This document provides design details for a 3-pile group supporting a column. Key details include: - The pile cap will be 1350mm thick, 2650mm wide, and 2430mm long. - Reinforcement is required in both the X and Y directions due to tensile forces of 48.34 kN in each direction. - Shear reinforcement consisting of 10mm diameter stirrups spaced at 200mm is required to resist shear forces of 1800kN. - Punching shear is also considered and found to be safe with the provided nominal shear reinforcement.

Uploaded by

Hemam Prasanta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views4 pages

Design For 3-Pile Group

This document provides design details for a 3-pile group supporting a column. Key details include: - The pile cap will be 1350mm thick, 2650mm wide, and 2430mm long. - Reinforcement is required in both the X and Y directions due to tensile forces of 48.34 kN in each direction. - Shear reinforcement consisting of 10mm diameter stirrups spaced at 200mm is required to resist shear forces of 1800kN. - Punching shear is also considered and found to be safe with the provided nominal shear reinforcement.

Uploaded by

Hemam Prasanta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

PROJECT :

FILE PATH: D:\downloaded spreadsheets\[PILE CAP DESIGN .xls]2-Pile

Design for 3-Pile Group


2
Concrete Fck,Steel Fy 30 500 N/mm
Pile Dia (hp) 600 mm
Column Dim (a,b) 600 600 mm
Spacing factor of piles (α) 2.75
Spacing between centers of piles (l) 1650 mm
Thickness of pile cap (h) 1350 mm 2430
Width of pile cap 2650 mm
Length of Pile Cap 2430 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 360 Ton
Effective depth of pile cap (d) 1275 mm

Neglecting Column Size (Nl/9d) 51.76


Taking size of column into consideration
Parallel to X-X 48.34
Parallel to Y-Y 48.34

Tensile steel required (Sq. In) 4.29


Tensile steel required (Sq.cm) 25.88
2
Reinforcement @ 0.15% of Pile cap area X-X plane 5068.13 mm
2
Reinforcement @ 0.15% of Pile cap area Y-Y plane 4647.38 mm 1350

Provide reinforcement in X-Direction


Bar Dia 25 mm
Number Of Bars Required 10.3
Number Of Bars Provided 12
Ast Provided 5890.688
SAFE

Provide reinforcement in Y-Direction


Bar Dia 25 mm
Number Of Bars Required 2.1 Pile
Number Of Bars Provided 12 Depth
SAFE

Oneway Shear
Diagonal tension @ 0.5d distance from face of
pedestal 637.5 mm
Shear Force,VU 1800 kN
Percentage of Steel,Pt 0.17 %
2
Shear strenth of concrete,Tc 0.21 N/mm
2
Shear stress,Tv 0.53 N/mm
DESIGN FOR SHEAR
Two-Way Shear
Design Shear,Vus 1090463 N Critical shear (punching s
Bar dia 10 78.5 Shear force
Spacing of Stirrups,Sv 239.5574 mm Punching shear section bo
say provide stirrups 6lgd-10Ø @ 200 mm c/c Nominal shear stress Tv
Allowable shear stress,Tc
Safe, provide nominal sh
DEALT :
DATE :

1650

X X
b

Y
2650
b
1025 PLAN

#12-25Ø
B/W

Depth

600 Ø 600 Ø
SECTION
Two-Way Shear
Critical shear (punching shear)
Shear force 1800 kN
Punching shear section bo 3150 mm
2
Nominal shear stress Tv 0.45 N/mm
2
Allowable shear stress,Tc 1.37 N/mm
Safe, provide nominal shear rein