AN6001-G16 Optical Line Terminal Equipment Product Overview Version A
AN6001-G16 Optical Line Terminal Equipment Product Overview Version A
AN6001-G16 Optical Line Terminal Equipment Product Overview Version A
Product Overview
Version: A
Code: MN000003548
June 2018
Thank you for choosing our products.
2 Product Introduction........................................................................................3
3 Product Highlights...........................................................................................7
4 Product Application.........................................................................................9
6 Product Structure..........................................................................................17
7 Matching Cables...........................................................................................25
A.4 Reliability........................................................................................47
Appendix D Abbreviations............................................................................62
1 Documentation Guide
Document Orientation
Intended Readers
u Marketing personnel
u Commissioning engineers
Version Information
Version Version Information
A Initial version, corresponding to the equipment version V1R1.
Content
Chapter Content
u Product appearance
Product Introduction u Product positioning
u Power supply mode
u Logical architecture
Product Structure u Hardware structure
u Software architecture
Functions, model numbers, structures, connections and
Matching Cables
parameters of wires and cables
Version: A 1
AN6001-G16 Optical Line Terminal Equipment Product Overview
Chapter Content
u Requirements for operating environment
Detailed Technical u Card dimensions
Specifications u GPON performance
u Reliability
Standards and Protocols Standards and protocols that the equipment complies with
Panel and Terminals of the PDP Model numbers, panels and terminals of the PDPs
Related Documentation
Document Applied to
AN6001-G16 Optical Line Terminal Equipment CLI Network deployment phase / network
Configuration Guide maintenance phase
2 Version: A
2 Product Introduction
Product Appearance
Product Positioning
Version: A 3
AN6001-G16 Optical Line Terminal Equipment Product Overview
The AN6001-G16 supports three power supply schemes: DC-AC, dual-DC, and
dual-AC. The figures below show the appearance of the equipment.
4 Version: A
2 Product Introduction
The AN6001-G16 provides three power supply schemes: dual-DC, dual-AC and
DC-AC hybrid schemes. All these schemes support 1+1 redundancy backup.
AC Power Supply
Version: A 5
AN6001-G16 Optical Line Terminal Equipment Product Overview
DC Power Supply
The table below describes the model numbers, appearance and input / output
specifications of the PDPs for the DC power supply scheme of the AN6001-G16.
Appearance
Range of input
-38 V to -60 V -38 V to -60 V
voltage
Two channels of power (one active Two channels of power (one active
Input channels
and one standby) and one standby)
Output
Six channels of output power Six channels of output power
channels
The maximum current of a single The maximum current of a single
Output current
channel is 32 A. channel is 32 A.
Note:
6 Version: A
3 Product Highlights
u 1U high, designed with modularized core switch service card, fan card and
power card for easy installation and replacement.
u Supports 16 GPON ports, two 10GE uplink ports (SFP+), two GE uplink optical
ports (SFP) and two GE uplink electrical ports to allow access of 1024 ONUs.
Flexible Deployment
Carrier-class Reliability
u Supports 1+1 redundancy protection for PON ports, uplink ports and power
interfaces. All the slots meet the requirement of fault tolerance.
u Supports service switching with the WTR time less than 50 ms.
Version: A 7
AN6001-G16 Optical Line Terminal Equipment Product Overview
u Supports IGMP Snooping and Proxy, IGMPv3 and MLDv2 source address
filtering, and rate control for multicast packets.
u Supports both IPv4 and IPv6 to enable smooth migration to the next-generation
IP network.
u Supports remote software upgrade, which simplifies operation and saves man
power.
8 Version: A
4 Product Application
In this scenario, the AN6001-G16, used together with various ONUs, provides
integrated user interfaces and abundant service functions to aggregate, merge, and
forward user data to meet various service access demands of telecommunications,
radio and television operators as well as the customer premises network.
Through uplink ports, the AN6001-G16s can be cascaded to make up an MSTP ring,
so as to provide redundancy protection and enhance network reliability
Version: A 9
AN6001-G16 Optical Line Terminal Equipment Product Overview
10 Version: A
5 Product Specification
Interface Specifications
Version: A 11
AN6001-G16 Optical Line Terminal Equipment Product Overview
12 Version: A
5 Product Specification
Classification Function
Supports voice intercommunication inside the PON.
1588v2 clock
Clocks
Adaptive clock recovery
Version: A 13
AN6001-G16 Optical Line Terminal Equipment Product Overview
Classification Function
Supports limit on maximum number of MAC addresses
learned to prevent attacks by users' MAC addresses.
14 Version: A
5 Product Specification
Item Description
Note 1: The overall power consumption is measured under the following conditions:
u Maximum power consumption: all the ports are 100% loaded.
u Static power consumption: all the ports are unloaded, and the optical ports are not plugged with optical modules.
Note 2: The working temperature is measured within an altitude of 1800 m. The ambient temperature of the
equipment will reduce by 1°C for each altitude rise of 220 m.
The pluggable optical modules applied to the AN6001-G16 have two encapsulation
formats: SFP and SFP+.
There are two types of module interfaces: LC and SC, as shown in the figure below.
The table below describes the mappings between the modules and the equipment
interfaces.
Equipment
Module Type Application Code Module Code
Interface
Version: A 15
AN6001-G16 Optical Line Terminal Equipment Product Overview
The AN6001-G16 also provides four network ports for RJ-45 connectors. The table
below describes the mapping between the ports and the cables connected.
Equipment
Interface Description Cable Connected
Interface
u RS232 local debugging serial port u Serial Port Line
(CONSOLE) u Environment
CONSOLE/ESC
u RS485 environment monitoring Monitoring Unit
interface (ESC) Connection Cable
1PPS/TOD External clock device interface Network Cable
Out-of-band network management
ETH Network Cable
interface
DC1-7 Dry contact interface Dry Contact Cable
16 Version: A
6 Product Structure
Logical Architecture
Hardware Structure
Software Architecture
Version: A 17
AN6001-G16 Optical Line Terminal Equipment Product Overview
The AN6001-G16 implements the switching based on IP packet core. The core
switch service card communicates via the backplane buses (combination of the data
bus and management bus) interconnected at high speed to exchange service data
or management information.
18 Version: A
6 Product Structure
This section introduces the subrack structure, functional modules, indicator LEDs
and air cooling mode for the AN6001-G16.
The figure below shows the components of the AN6001-G16 subrack using the AC-
DC hybrid power supply scheme as an example.
Version: A 19
AN6001-G16 Optical Line Terminal Equipment Product Overview
⑧ Subrack earth ground point Connects with the subrack earth ground cable.
Module Allocation
20 Version: A
6 Product Structure
Virtual Card
The AN6001-G16 implements the upper-layer management in the virtual card mode.
The core switch service card (HSOA) integrates three virtual cards: GPOP, HSCP
and HU2P. The virtual cards are integrated with the subrack and cannot be plugged
/ unplugged or replaced.
The figure below illustrates the allocation of virtual slots in the AN6001-G16 subrack.
Indicator LEDs
Blinking
The card is being initialized.
ACTNote 1 Working indicator LED Green slowly
Version: A 21
AN6001-G16 Optical Line Terminal Equipment Product Overview
Note 1: The ACT indicators of the power card and fan card do not have the Blinking Slowly status.
Note 2: The left and right LINK indicators correspond to the upper and lower GPON ports respectively.
Note 3: The left and right LINK indicators correspond to the upper and lower uplink optical ports respectively.
The AN6001-G16 is designed with forced air cooling. The fan card is located at the
right side of the subrack (front view). The cool air is drawn from the left side to the
right side of the subrack to take away the heat, as illustrated in the figure below.
The figure below illustrates the core switch software architecture of the AN6001-
G16.
22 Version: A
6 Product Structure
u Support plane: Serves the entire system, available for all the layers and
modules in the system; provides universal operating system and supports
hardware transplantation; provides complete software tool set, session
management, and IPC encapsulation.
u Control plane: Controls the operation of all network protocols; supports flexible
configuration of functional modules to cater to various application scenarios.
u Data plane: Manages the configuration data, status data, alarm time data and
operation data of functional modules and protocol modules in the system
collectively.
The figure below illustrates the service software architecture of the AN6001-G16.
Version: A 23
AN6001-G16 Optical Line Terminal Equipment Product Overview
u System support layer: Provides system support and fault diagnosis functions
such as the operating system abstract layer (OSAL), command lines, logs and
hot patches.
u PON driver isolation layer: Defines the universal PON_API interface and
shields the difference in underlying hardware schemes so that the upper-layer
software can make use of the OLT underlying hardware functions.
u Service logic layer: Defines the service model and the service modules based
on it.
24 Version: A
7 Matching Cables
Cable Overview
Power Cable
Fiber Jumper
Network Cable
Version: A 25
AN6001-G16 Optical Line Terminal Equipment Product Overview
Subrack DC Power
408000062 The PWRD card of the equipment
Cable
Subrack AC Power
WX00219 The PWRA card of the equipment
Cable
Connecting the earth ground point
Cabinet Protection Earth on the top of the cabinet and the
408000041 (16 mm2), 408000019 (25 mm2)
Ground Cable ground busbar in the equipment
room
Subrack Protection Earth
3696084 The equipment subrack
Ground Cable
LC/PC-type optical fiber jumper: OFC-LC/PC- The 10GE1 / 10GE2 port or GE3 /
LC/PC-S-20 GE4 port of the HSOA card
Fiber Jumper
SC/PC-type optical fiber jumper: OFC-SC/PC-
Ports 1 to 16 of the HSOA card
SC/PC-S-20
The GE5 / GE6 port, 1PPS/TOD
Network Cable 3695095 interface or ETH interface of the
HSOA card
Environment Monitoring The CONSOLE/ESC interface of
409000159
Unit Connection Cable the HSOA card
The CONSOLE/ESC interface of
Serial Port Line 3695341
the HSOA card
The DC1-7 interface of the HSOA
Dry Contact Cable 3695452
card
26 Version: A
7 Matching Cables
The power cables supply electric energy to loads so that the loads can work
normally.
Function
The cabinet power cables, including the -48 V power cable and the 0 V power cable,
are used to induct the power source for the equipment room to the PDP inside the
cabinet.
Model
The AN6001-G16 can use the PDP260B (3000063) or PDP296B (3000068). The
cabinet power cables vary with the PDP used. Table 7-1 describes the mappings
between the cabinet power cables and the PDPs. Please refer to this table and
select appropriate cabinet power cables for the PDP.
Structure
Version: A 27
AN6001-G16 Optical Line Terminal Equipment Product Overview
Connection
-48V_A connector
-48 V power cable (active) External -48 V
(blue) -48V_B connector connector
PDP296B
(standby)
(3000068)
0V_A connector (active)
0 V power cable External 0 V
0V_B connector
(black) connector
(standby)
Technical Specifications
Item Specification
Function
The subrack DC power cable connects the PDP and the equipment's DC power
card (PWRD) to induct a set of redundant branch power rails from the PDP to the
subrack.
Model
The model number of the subrack DC power cable for the AN6001-G16 is
408000062.
28 Version: A
7 Matching Cables
Structure
The subrack DC power cable has a two-conductor power plug on one end and two
cord end terminals on the other end, as illustrated in the figure below.
(1) Two-conductor power plug (2) -48 V cord end terminal (3) 0 V cord end terminal
Connection
Connection Description
No. Cable Connector
PDP260B (3000063) PDP296B (3000068)
Technical Specifications
Item Specification
Maximum current 16 A
Cross-sectional area of the conductor 2 × 1.5 mm2
Function
The subrack AC power cable is used to connect the external AC power supply and
the AC power card (PWRA) of the equipment, inducting the external AC power into
the subrack.
Version: A 29
AN6001-G16 Optical Line Terminal Equipment Product Overview
Model
Structure
As shown in the figure below, the subrack AC power cable has a three-conductor
power plug on one end and a three-conductor power jack on the other end.
Connection
Tree-conductor
Connected to the external power supply unit.
Subrack AC power plug
cable Tree-conductor Connected to the power input interface of the AC
jack power card (PWRA).
The protection earth ground cables (including the cabinet protection earth ground
cable and the subrack protection earth ground cable) protect the equipment from
lightning and interference.
Function
The cabinet protection earth ground cable is used to connect the earth ground point
on the top of the cabinet and the ground busbar in the equipment room.
30 Version: A
7 Matching Cables
Model
The AN6001-G16 can use the cabinet protection earth ground cables with the
model numbers 408000041 (16 mm2) and 408000019 (25 mm2).
Structure
As shown in the figure below, the yellow- / green cable has an M6 uninsulated ring
terminal on one end for connection with the cabinet. You need to make a grounding
terminal on the other end of the cable for connection with the busbar.
Connection
M6 uninsulated ring
Connected to the earth ground point on the top of the cabinet.
terminal
Bare wire terminal Prepared according to the earth ground point on the busbar.
Technical Specifications
Item Specification
Function
The subrack protection earth ground cable is used to connect the subrack and the
protection earth ground terminal of the cabinet to provide ground protection for the
subrack.
Version: A 31
AN6001-G16 Optical Line Terminal Equipment Product Overview
Model
The model number of the subrack protection earth ground cable used by the
AN6001-G16 is 3696084.
Structure
The figure below shows the subrack protection earth ground cable. Both ends of the
cable are M6 pre-insulation terminals, and between them is a yellow- / green cable.
Connection
Technical Specifications
Item Specification
Maximum current 32 A
Cross-sectional area of the conductor 4 mm2
32 Version: A
7 Matching Cables
Function
The PDP protection earth ground cable is used to connect the protection ground of
the PDP and the earth ground point on the top of the cabinet. Before delivery, this
cable has been connected to the PE terminal of the PDP.
Model
Structure
Comprises an M10
uninsulated ring terminal at
the PDP side and an M6
3696239 uninsulated ring terminal at
the cabinet side, with a
yellow- / green cable between
them.
Comprises an M6 uninsulated
copper cord end terminal at
the PDP side and an M6 pre-
408000018
insulation ring terminal at the
cabinet side, with a yellow- /
green cable between them.
Version: A 33
AN6001-G16 Optical Line Terminal Equipment Product Overview
Connection
Note:
The PDP protection earth ground cable has been connected to the inner
PE connector of the PDP before delivery; therefore, you only need to
connect the cable to the earth ground point on the top of cabinet on site.
Technical Specifications
Serving as the transmission carrier of optical signals, the fiber jumper is applied to
the short-distance transmission of optical signals. It connects an optical interface of
the equipment's card and the ODF.
Model
Classification Model
LC/PC-type optical fiber jumper OFC-LC/PC-LC/PC-S-20
SC/PC-type optical fiber jumper OFC-SC/PC-SC/PC-S-20
34 Version: A
7 Matching Cables
Structure
Classification Connector
Connection
Cable Connector Card Interface Connected Connection on the ODF Side
Connected to the remote ONU to
SC/PC connector Ports 1 to 16 of the HSOA card
provide the GPON downlink channel.
The network cable is used to connect the local equipment to the uplink equipment,
out-of-band network management system or time synchronization device.
Model
The model number of the network cable (including straight-through network cable
and cross-over network cable) is 3695095.
Version: A 35
AN6001-G16 Optical Line Terminal Equipment Product Overview
Structure
Both ends of the network cable are equipped with the RJ-45 connectors (also
known as crystal heads), as shown in the figure below.
Table 7-3 lists the pin definitions for the straight-through network cable.
Pin of the Local End Wire Color Pin of the Opposite End
1 White- / orange 1
2 Orange 2
3 White- / green 3
4 Blue 4
5 White- / blue 5
6 Green 6
7 White- / brown 7
8 Brown 8
Table 7-4 lists the pin definitions for the cross-over network cable.
Pin of the Local End Wire Color Pin of the Opposite End
1 White- / orange 3
2 Orange 6
3 White- / green 1
4 Blue 4
5 White- / blue 5
36 Version: A
7 Matching Cables
Table 7-4 Pin Definitions for the Cross-over Network Cable (Continued)
Pin of the Local End Wire Color Pin of the Opposite End
6 Green 2
7 White- / brown 7
8 Brown 8
Connection
The GE5 / GE6 port, ETH Connected to the uplink equipment, out-
Network cable interface or 1PPS/TOD interface of-band network management system
of the HSOA card or time synchronization device.
Technical Specifications
Item Specification
Model
Version: A 37
AN6001-G16 Optical Line Terminal Equipment Product Overview
Structure
The table below defines the pins of the environment monitoring unit connection
cable.
Pin of the Local End Wire Color Pin of the Opposite End
1 White- / orange 7
2 Orange 8
7 White- / brown 5
8 Brown 6
The serial port line is used for debugging or local maintenance. It connects the local
debugging serial port of the HSOA card and the serial port of the network
management computer.
Model
38 Version: A
7 Matching Cables
Structure
Table 7-5 lists the terminal definitions for the serial port line.
GND 4/5 5
Signal received by the
6 3
equipment
Connection
Technical Specifications
Item Specification
Version: A 39
AN6001-G16 Optical Line Terminal Equipment Product Overview
The dry contact cable is used to connect the dry contact interface on a card to an
external dry contact device to enable monitoring of infrared detection, smoke, mains
supply, humidity, temperature, fans, shake, door access control, etc.
Model
Structure
Connection
Cable Cable Connector Connection Description
Technical Specifications
Item Specification
40 Version: A
8 Indoor Cabinets
Overview of Cabinets
Version: A 41
AN6001-G16 Optical Line Terminal Equipment Product Overview
Appear-
ance
Note 1:
u Among the SC/PC optical fiber connectors, the 55 mm long and 39 mm long ones are
most commonly used. The 55 mm ones are called long connectors, and the 39 mm ones
are called short connectors. When the equipment is mounted in a 300 mm-deep cabinet, it
Remarks is advisable to use the 39 mm optical fiber connectors (short connectors).
u Among the LC/PC optical fiber connectors, the 48 mm long and 31 mm long ones are
most commonly used. The 48 mm ones are called long connectors, and the 31 mm ones
are called short connectors. When the equipment is mounted in a 300 mm-deep cabinet, it
is advisable to use the 31 mm optical fiber connectors (short connectors).
42 Version: A
8 Indoor Cabinets
The following introduces the detailed dimensions of the 19-inch and 21-inch
cabinets.
Version: A 43
AN6001-G16 Optical Line Terminal Equipment Product Overview
Item Specification
44 Version: A
8 Indoor Cabinets
Item Specification
Version: A 45
Appendix A Detailed Technical
Specifications
HF ≤ 0.01 mg/m3
O3 ≤ 0.05mg/m3
The AN6001-G16 contains the HSOA, PWRA/PWRD and FAN cards. The table
below lists the dimensions of the cards.
46 Version: A
Appendix A Detailed Technical Specifications
A.4 Reliability
Equipment Model Basic Reliability Task Reliability
Version: A 47
Appendix B Standards and
Protocols
48 Version: A
Appendix B Standards and Protocols
Version: A 49
AN6001-G16 Optical Line Terminal Equipment Product Overview
50 Version: A
Appendix B Standards and Protocols
Version: A 51
AN6001-G16 Optical Line Terminal Equipment Product Overview
IEC Publication 479-1 Guide on the effects of current passing through the human body
IS 8437 {1993} Guide on the effects of current passing through the human body
ITU-T G.984.5 Enhancement band for gigabit capable optical access networks
ITU-T G.711.1 Wideband embedded extension for G.711 pulse code modulation
52 Version: A
Appendix B Standards and Protocols
IETF RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6
Version: A 53
AN6001-G16 Optical Line Terminal Equipment Product Overview
Time Standards
Standard Number Title
IEEE Standard for a Precision Clock Synchronization Protocol for
IEEE 1588-2008
Networked Measurement and Control Systems
Ethernet Protocols
Standard Number Title
IEEE Standard for Local and Metropolitan Area Networks:
IEEE 802-2001
Overview and Architecture
IEEE Standard for Local and Metropolitan Area Networks - Virtual
IEEE 802.1ad
Bridged Local Area Networks - Amendment 4: Provider Bridges
54 Version: A
Appendix B Standards and Protocols
Version: A 55
AN6001-G16 Optical Line Terminal Equipment Product Overview
ITU-T Rec L.53 Optical fibre maintenance criteria for access networks
56 Version: A
Appendix C Panel and Terminals of
the PDP
The following introduces the terminal board and power connectors of the PDP260B
(3000063).
Terminal Board
(1) Branch power rail output (2) External power -48 V (3) External power 0 V input
connector 1 input connector connector
(4) Protection earth ground (5) Branch power rail output (6) Automatic circuit breaker
cable connector connector 2
(7) Branch power rail 0 V (8) Branch power rail 0 V
output connector 1 output connector 2
Power Connectors
Connector Type No. Connector Description
Version: A 57
AN6001-G16 Optical Line Terminal Equipment Product Overview
The following introduces the front panel, terminal board, power / alarm connectors,
jumper pins and lightning protection module of the PDP296B (3000068).
Front Panel
The PDP296B (3000068) has six air automatic circuit breakers on its front panel to
control the power supply outputs. Among which:
u The ACBs SW1-1 to SW1-3 control the branch power rails -48V_A_1 to
-48V_A_3 respectively .
u The ACBs SW2-1 to SW2-3 control the branch power rails -48V_B_1 to
-48V_B_3 respectively .
58 Version: A
Appendix C Panel and Terminals of the PDP
Terminal Board
(1) Branch power rail -48V (2) Alarm connector for the (3) Cabinet top indicator LED
output connector A head of row cabinet alarm connector
(4) External power -48V input (5) External power 0V input (6) Protection earth ground
connector connector cable connector
(7) Branch power rail -48V (8) Branch power rail 0V (9) Lightning protection module
output connector B output connector B
(10) Jumper pin for selecting (11) Branch power rail 0V (12) Subrack alarm
the working status indicator output connector A convergence connector
LED of the PDP
(13) Buzzer
Power Connectors
Connector Type No. Connector Description
Branch power rail output Automatic circuit breakers (ACBs). The outer
-48V_B_1 to -48V_B_
(2 × 3 channels) (7) connectors are -48 V branch power rail output
3
connectors corresponding to -48V_B.
Version: A 59
AN6001-G16 Optical Line Terminal Equipment Product Overview
Alarm Connector
Connector Type No. Connector Description
Jumper Pin
JP1 is the jumper pin for selecting the operating status indicator LED of the PDP. It
is located as indicated by (10) in the figure, and can be set in either of the following
two ways:
u Short pin1 and pin2 of JP1, and the green indicator LED on the top of the
cabinet will indicate the working status of the PDP.
u Short pin2 and pin3 of JP1, and the green indicator LED on the top of the
cabinet will be controlled by the CALL (order wire call) signal.
Note:
Pin2 and pin3 of JP1 have been shorted by default before delivery of the
PDP.
The lightning protection module is plugged into the base of XS3, as indicated by (9)
in the figure.
60 Version: A
Appendix C Panel and Terminals of the PDP
The lightning protection module, using the standard DB-25 plug, can withstand the
surge of 2 kV (1.2/50 us - 8/20 us combination wave) in the common mode and the
surge of 1 kV (1.2/50 us - 8/20 us combination wave) in the differential mode, so as
to guarantee the normal operation of the equipment.
Version: A 61
Appendix D Abbreviations
IP Internet Protocol
IPTV Internet Protocol Television
IPv4 Internet Protocol version 4
IPv6 Internet Protocol version 6
LACP Link Aggregation Control Protocol
62 Version: A
Appendix D Abbreviations
Version: A 63
AN6001-G16 Optical Line Terminal Equipment Product Overview
64 Version: A
Product Documentation Customer Satisfaction Survey
Thank you for reading and using the product documentation provided by FiberHome. Please take a moment to
complete this survey. Your answers will help us to improve the documentation and better suit your needs. Your
responses will be confidential and given serious consideration. The personal information requested is used for
no other purposes than to respond to your feedback.
Name
Phone Number
Email Address
Company
To help us better understand your needs, please focus your answers on a single documentation or a complete
documentation set.
Documentation Name
Code and Version
12. Additional comments about our documentation or suggestions on how we can improve:
Thank you for your assistance. Please fax or send the completed survey to us at the contact information
included in the documentation. If you have any questions or concerns about this survey please email at
[email protected]