Design of Column: Axial Stress 0.1fck

1. The document summarizes the design of a column with dimensions of 600mm x 500mm x 3048mm height that is subjected to an axial load of 3870.98 kN and moments. 2. The column is designed as a short column with grade M25 concrete and Fe500 steel reinforcement. 3. The column section is designed to resist the factored axial load and biaxial bending moments using SP-16 interaction diagrams, with 12 numbers of 30mm diameter longitudinal bars provided. Transverse ties of 10mm diameter spaced at 300mm are also designed.

Uploaded by

Sudip Shrestha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
522 views22 pages

Design of Column: Axial Stress 0.1fck

1. The document summarizes the design of a column with dimensions of 600mm x 500mm x 3048mm height that is subjected to an axial load of 3870.98 kN and moments. 2. The column is designed as a short column with grade M25 concrete and Fe500 steel reinforcement. 3. The column section is designed to resist the factored axial load and biaxial bending moments using SP-16 interaction diagrams, with 12 numbers of 30mm diameter longitudinal bars provided. Transverse ties of 10mm diameter spaced at 300mm are also designed.

Uploaded by

Sudip Shrestha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 22

Design of column

column2 (frame ID 766)-R8 for load combo : 1.5(DL+EQy)


Grade of conc = M 25 Grade of steel = Fe500(HYSD)
Reference SN Calculation Output Remarks
1 Known data
Dimension of column dx 600 mm
dy 500 mm
Height,L = 3.048 m
depth of beam 550 mm
slab thickness 150
Clear height,l = 2.348 m unsupported ht
clear cover= 40 mm
Assumed data:
effective cover, d' = 70 mm 40+25/2
2 Check for axial stress
0.1fck= 2.5 N/mm2
Factored Axial load = 3870.98 kN
IS 13920:1993 Factored axial stress = 12.90 N/mm2
cl.7.1.1 Hence design as column member. axial stress>0.1fck
3 Check for member size:
along x, Dx = 600 mm >200 mm
along y, Dy = 500 mm >200 mm
IS 13920:1993 Dx/Dy = 1.2 >0.4
cl.7.1.2 Hence, OK.
IS 456:2000
table 28 effective length,Le = 1.5262 m 0.65*unsupported
length
Check for short and slender column:
Le/Dx = 2.544 < 12
Le/Dy = 3.052 < 12
So, it is short column

4 Design of section
Pu = 3870.978 kN
Mux = 121.288 kN-m
Muy = 274.887 kN-m
eccentricity due to load,
ex = 31.33265 mm
ey = 71.012287 mm
minimum eccentricity,
exmin = (L/500+Dx/30) or 20mm 20 mm
eymin = (L/500+Dy/30) or 20mm 21.362667 mm
permissible eccentricity,
ex permissible = 0.05Dx = 30 mm
ey permissible = 0.05Dy = 25 mm
design eccentricity,
ex design = 31.33265 mm
ey design = 71.012287 mm

Biaxially Loaded Column


For biaxially loaded column
Mu' = 1.15√(Mux^2+Muy^2) = 345.52408 kNm
SP 16 Chart assuming for the value of d'/Dx= 0.1166667
d'/Dy= 0.14
and reinforcement equally along all 4 sides
Pu/(fck*Dx*Dy) = 0.516
Mu'/(fck*Dx*Dy^2) = 0.0921398
Pt/fck = 0.1 interaction
So, Pt = 2.5 % diagrm chart 48
Sp 16 Chart for d'/Dx = 0.117 and Pt/fck = 0.113
Mu'/(fck*Dx^2*Dy) = 0.120
So, Mux1 = 540 kNm
for d'/Dy = 0.14 and Pt/fck = 0.113
Muy1/(fck*Dx*Dy^2) = 0.110
So, Muy1 = 412.5 kNm
IS 456:4000 Puz = 0.45fck*Ag + 0.75fy*As = 5709.375 kN
cl.39.6 then for αn
Pu/Puz = 0.678
so, αn = 1.797
now, (Mux/Mux1)^αn+(Muy/Muy1)^αn = 0.551 < 1,So Pt is safe
so, area of steel required, As = 7500 mm2
providing 30mm φ bars, no. required = 10.610 no. eqv =12no
As provided = 8482.3 mm2
So, Pt provided will be = 2.827 %
Checks
IS 456:2000 As max = 4% of Ag = 12000 mm2 OK
cl.26.5.3.1 As min = 0.8% of Ag = 2400 mm2 OK
2
But in extreme case, As= 6% of Ag 18000 mm

5 Design of transverse reinforcement


for shear
IS 456:2000 Design shear strength of concrete, τc = 0.9062 N/mm2 for M25 concrete
Table 19 grade and for Pt
provided
IS 456:2000 For members subjected to axial
cl.40.2.2 compression Pu, the design shear strength
of concrete τc shall be multiplied by
following factor:
δ(not greater than 1.5)=1+3Pu/(Ag*fck) 1.500
so, modified τc = 1.359 N/mm2
shear capacity of section
Vc = τcmod.*DxDy 407.790 kN

Design shear force for columns shall


be maximum of:
a) calculated factored shear force
as per analysis
Is 13920:1993 b) a factored shear force given by
cl.7.3.4 Vu = 1.4(MbLulim + MbRulim)/hst
where hst = storey height = 3.048 m
and M = moment of resistance of
beams(of opp. Sign)
a) Shear force as per ETABS analysis
Vux = 179.278 kN
Vuy = 249.776 kN
b) MbLulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 320.37656 kNm
MbRulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 324.12717 kNm
So, Vu = 296.0319 kN
shear capacity of column section exceeds
induced shear force in both cases . So providing
nominal shear reinforcement

Requirement for design of lateral ties


IS 456:2000 diameter φt > ( 6mm and 1/4*largest φlong.) 8 mm
spacing < (Dmin and 16*smallest φlong. 300 mm
and 300mm)
so adopting ties of 10mm dia

6 Design of Special-confining reinforcement


IS 13920 Special confinig reinforecement bar shall
cl.7.4.1 be provided over a length L0 from each
face towards the midspan on either side
of any cross section where flexural yielding
occurs under the effect of Earthquake force
So, L0 =
i) larger lateral dimension of member= 600 mm
ii) 1/6 * clear span= 391.33333 mm
iii) 450mm 450 mm
Hence, adopt Lo=600mm on either
side from the joint.
Size of column= 600*500
then,
size of core, Dkx=600-2*55+2*10 510 mm
Dky=500-2*55+2*10 410 mm
so, core area, Ak= 390*540mm^2 209100 mm2
h=max of { 540/2 and 390/2} = 270 205

IS13920 Area of cross section of bar(Ash)


cl.7.4.8 forming rectangular hoop, to be used as
confinig reinforcement shall not be
less than
Ash=0.18*S*h*fck/fy(Ag/Ak-1)

where,
Ash= Area of bar cross section
Ag= Gross area of column
Ak= Area of concrete
S= Pitch of hoops
h= Length of rectangular confining hoop
measured to its outer face
from above eqn,
or, 78.539=0.18*S*205*25/500*((600*500)/209100-1)
S= 97.922

Spacing of hoops shall not exceed the


smaller of
IS13920 a) 1/4 of minimum member dimension 150 mm
cl.7.4.6 b) S<= 100 mm
c) S> 75 mm

Hence,provide 10mmФ @ 75mm c/c


for a distance of Lo=600mm on either side.
0.0176659809
left beam right beam
pt 0.71 0.72
b 400 400
d 550 550
Design of column
column1 (frame ID 849)-M8 for load combo : 1.5(DL+LL)
Grade of conc = M 25 Grade of steel = Fe500(HYSD)
Reference SN Calculation Output
1 Known data
Dimension of column dx 700 mm
dy 600 mm
Height,L = 3.2 m
depth of beam 550 mm
slab thickness 150 mm
Clear height,l = 2.65 m
clear cover= 40 mm
Assumed data:
effective cover, d' = 70 mm
2 Check for axial stress
0.1fck= 2.5 N/mm2
Factored Axial load = 6869.623 kN
IS 13920:1993 Factored axial stress = 16.36 N/mm2
cl.7.1.1 Hence design as column member.
3 Check for member size:
along x, Dx = 700 mm
along y, Dy = 600 mm
IS 13920:1993 Dx/Dy = 1.1666667
cl.7.1.2
IS 456:2000
table 28 effective length,Le = 1.7225 m

Check for short and slender column:


Le/Dx = 2.461
Le/Dy = 2.871
So, it is short column

4 Design of section
Pu = 6869.623 kN
Mux = 7.0719 kN-m
Muy = 181.364 kN-m
eccentricity due to load,
ex = 1.0294451 mm
ey = 26.400867 mm
minimum eccentricity,
exmin = (L/500+Dx/30) or 20mm 20 mm
eymin = (L/500+Dy/30) or 20mm 25.3 mm
permissible eccentricity,
ex permissible = 0.05Dx = 35 mm
ey permissible = 0.05Dy = 30 mm
Here,
ex < 0.05DX
ey < 0.05Dy
so, designed as axially loaded column
Pu = 0.4*Fck*(Ag-As)+0.67*Fy*As
As = 8214.22mm^2
providing 25mm φ bars, no. required = 16.734 no.
As provided = 9817.477 mm2
So, Pt provided will be = 2.340 %
Checks
IS 456:2000 As max = 4% of Ag = 16800 mm2
cl.26.5.3.1 As min = 0.8% of Ag = 3360 mm2
But in extreme case, As= 6% of Ag 25200 mm2

5 Design of transverse reinforcement


for shear
IS 456:2000 Design shear strength of concrete, τc = 0.813 N/mm2
Table 19

IS 456:2000 For members subjected to axial


cl.40.2.2 compression Pu, the design shear strength
of concrete τc shall be multiplied by
following factor:
δ(not greater than 1.5)=1+3Pu/(Ag*fck) 1.500
so, modified τc = 1.220 N/mm2
shear capacity of section
Vc = τcmod.*DxDy 512.190 kN

Design shear force for columns shall


be maximum of:
a) calculated factored shear force
as per analysis
Is 13920:1993 b) a factored shear force given by
cl.7.3.4 Vu = 1.4(MbLulim + MbRulim)/hst
where hst = storey height = 3.2 m
and M = moment of resistance of

beams(of opp. Sign)


a) Shear force as per SAP
Vux = 27.928 kN
Vuy = 35.363 kN
b) MbLulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 232.5098 kNm
MbRulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 120.23013 kNm
So, Vu = 154.32372 kN
shear capacity of column section exceeds induced
shear force in both cases . So providing nominal
shear reinforcement

Requirement for design of lateral ties


IS 456:2000 diameter φt > ( 6mm and 1/4*largest φlong.) 6.25 mm
spacing < (Dmin and 16*smallest φlong. 300 mm
and 300mm)
so adopting ties of 10mm dia

6 Design of Special-confining reinforcement


IS 13920 Special confinig reinforecement bar shall
cl.7.4.1 be provided over a length L0 from each
face towards the midspan on either side
of any cross section where flexural yielding
occurs under the effect of Earthquake force
So, L0 =
i) larger lateral dimension of member= 700 mm
ii) 1/6 * clear span= 441.66667 mm
iii) 450mm 450 mm
Hence, adopt Lo=700mm on either
side from the joint.
Size of column= 700*600
then,
size of core, Dkx=700-2*52.5+2*8 611 mm
Dky=600-2*52.5+2*8 511 mm
so, core area, Ak= 511*611mm^2 312221 mm2
h=max of { 611/2 and 511/2} = 270 305.5

IS13920 Area of cross section of bar(Ash)


cl.7.4.8 forming rectangular hoop, to be used as
confinig reinforcement shall not be
less than
Ash=0.18*S*h*fck/fy(Ag/Ak-1)

where,
Ash= Area of bar cross section
Ag= Gross area of column
Ak= Area of concrete
S= Pitch of hoops
h= Length of rectangular confining hoop measured
to its outer face
from above eqn,
or,78.539=0.18*S*305.5*25/500*((700*600)/312221-1)
S= 82.75

Spacing of hoops shall not exceed the


smaller of
IS13920 a) 1/4 of minimum member dimension 150 mm
cl.7.4.6 b) S<= 100 mm
c) S> 75 mm

Hence,provide 10mmФ @ 75mm c/c


for a distance of Lo=700mm on either side.
mbo : 1.5(DL+LL)
teel = Fe500(HYSD)
Remarks

unsupported ht

40+25/2

axial stress>0.1fck

>200 mm
>200 mm
>0.4
Hence, OK.

0.65*unsupported
length

< 12
< 12
eqv =20 no.

OK
OK

for M25 concrete


grade and for Pt
provided

left beam right beam


pt 0.49 0.24
b 400 400
d 550 550
Design of column
column1 (frame ID 1029) for load combo : Envelope
Grade of conc = M 25 Grade of steel = Fe500(HYSD)
Reference SN Calculation Output
1 Known data
Dimension of column dx 700 mm
dy 600 mm
Height,L = 3.048 m
depth of beam 550 mm
slab thickness 150
Clear height,l = 2.348 m
clear cover= 40 mm
Assumed data:
effective cover, d' = 70 mm
2 Check for axial stress
0.1fck= 2.5 N/mm2
Factored Axial load = 5530.31 kN
IS 13920:1993 Factored axial stress = 13.17 N/mm2
cl.7.1.1 Hence design as column member.
3 Check for member size:
along x, Dx = 700 mm
along y, Dy = 600 mm
IS 13920:1993 Dx/Dy = 1.1666667
cl.7.1.2
IS 456:2000
table 28 effective length,Le = 1.5262 m

Check for short and slender column:


Le/Dx = 2.180
Le/Dy = 2.544
So, it is short column

4 Design of section
Pu = 5530.314 kN
Mux = 494.015 kN-m
Muy = 413.77 kN-m
eccentricity due to load,
ex = 89.328563 mm
ey = 74.818537 mm
minimum eccentricity,
exmin = (L/500+Dx/30) or 20mm 20 mm
eymin = (L/500+Dy/30) or 20mm 24.696 mm
permissible eccentricity,
ex permissible = 0.05Dx = 35 mm
ey permissible = 0.05Dy = 30 mm
design eccentricity,
ex design = 89.328563 mm
ey design = 74.818537 mm

Biaxially Loaded Column


For biaxially loaded column
Mu' = 1.15√(Mux^2+Muy^2) = 741.06453 kNm
SP 16 Chart assuming for the value of d'/Dx= 0.1
d'/Dy= 0.1166667
and reinforcement equally along all 4 sides
Pu/(fck*Dx*Dy) = 0.527
Mu'/(fck*Dx*Dy^2) = 0.1176293
Pt/fck = 0.12
So, Pt = 3%
Sp 16 Chart for d'/Dx = 0.1 and Pt/fck = 0.135
Mu'/(fck*Dx^2*Dy) = 0.150
So, Mux1 = 1102.5 kNm
for d'/Dy = 0.116 and Pt/fck = 0.135
Muy1/(fck*Dx*Dy^2) = 0.150
So, Muy1 = 945 kNm
IS 456:4000 Puz = 0.45fck*Ag + 0.75fy*As = 8646.75 kN
cl.39.6 then for αn
Pu/Puz = 0.640
so, αn = 1.733
now, (Mux/Mux1)^αn+(Muy/Muy1)^αn = 0.488
so, area of steel required, As = 12600 mm2
providing 25mm φ bars, no. required = 17.825 no.
As provided = 14137.167 mm2
So, Pt provided will be = 3.366 %
Checks
IS 456:2000 As max = 4% of Ag = 16800 mm2
cl.26.5.3.1 As min = 0.8% of Ag = 3360 mm2
But in extreme case, As= 6% of Ag 25200 mm2

5 Design of transverse reinforcement


for shear
IS 456:2000 Design shear strength of concrete, τc = 0.92 N/mm2
Table 19

IS 456:2000 For members subjected to axial


cl.40.2.2 compression Pu, the design shear strength
of concrete τc shall be multiplied by
following factor:
δ(not greater than 1.5)=1+3Pu/(Ag*fck) 1.500
so, modified τc = 1.380 N/mm2
shear capacity of section
Vc = τcmod.*DxDy 579.600 kN

Design shear force for columns shall


be maximum of:
a) calculated factored shear force
as per analysis
Is 13920:1993 b) a factored shear force given by
cl.7.3.4 Vu = 1.4(MbLulim + MbRulim)/hst
where hst = storey height = 3.048 m
and M = moment of resistance of
beams(of opp. Sign)
a) Shear force as per ETABS analysis
Vux = 205.663 kN
Vuy = 244.342 kN
b) MbLulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 426.80648 kNm
MbRulim = 0.87fy*Pt*bd^2/100*(1-1.005*fy/fck*Pt/100)= 312.81186 kNm
So, Vu = 339.71971 kN
shear capacity of column section exceeds induced shear
force in both cases . So providing nominal shear
reinforcement

Requirement for design of lateral ties


IS 456:2000 diameter φt > ( 6mm and 1/4*largest φlong.) 8 mm
spacing < (Dmin and 16*smallest φlong. 300 mm
and 300mm)
so adopting ties of 10mm dia

6 Design of Special-confining reinforcement


IS 13920 Special confinig reinforecement bar shall
cl.7.4.1 be provided over a length L0 from each
face towards the midspan on either side
of any cross section where flexural yielding
occurs under the effect of Earthquake force
So, L0 =
i) larger lateral dimension of member= 700 mm
ii) 1/6 * clear span= 391.33333 mm
iii) 450mm 450 mm
Hence, adopt Lo=700mm on either
side from the joint.
Size of column= 700*600
then,
size of core, Dkx=700-2*55+2*10 610 mm
Dky=600-2*55+2*10 510 mm
so, core area, Ak= 390*540mm^2 311100 mm2
h=max of { 540/2 and 390/2} = 270 305

IS13920 Area of cross section of bar(Ash)


cl.7.4.8 forming rectangular hoop, to be used as
confinig reinforcement shall not be
less than
Ash=0.18*S*h*fck/fy(Ag/Ak-1)

where,
Ash= Area of bar cross section
Ag= Gross area of column
Ak= Area of concrete
S= Pitch of hoops
h= Length of rectangular confining hoop measured to its
outer face
from above eqn,
or,78.539=0.18*S*305*25/500*((700*600)/311100-1)
S= 81.737

Spacing of hoops shall not exceed the


smaller of
IS13920 a) 1/4 of minimum member dimension 175 mm
cl.7.4.6 b) S<= 100 mm
c) S> 75 mm

Hence,provide 10mmФ @ 75mm c/c


for a distance of Lo=700mm on either side.
mbo : Envelope
teel = Fe500(HYSD)
Remarks

unsupported ht

40+25/2

axial stress>0.1fck

>200 mm
>200 mm
>0.4
Hence, OK.

0.65*unsupported
length

< 12
< 12
0.0719548475

interaction
diagrm chart 48

< 1,So Pt is safe

eqv =20 no.

OK
OK

for M25 concrete


grade and for Pt
provided
left beam right beam
pt 1.02 0.69
b 400 400
d 550 550

You might also like