1. Scope—This SAE Standard covers the general requirements and the test requirements for a flashing warning
lamp for industrial wheeled equipment.
2. References
2.1 Applicable Publications—The following publications form a part of this specification to the extent specified
herein. Unless otherwise specified, the latest issue of SAE publications shall apply.
2.1.1 SAE PUBLICATIONS—Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.
3. Definitions
3.1 Industrial Wheeled Equipment—That class of tractors and associated equipment used in operations such as
landscaping, construction services, loading, digging, grounds keeping, and highway maintenance.
3.2 Flashing Warning Lamp—A lighted device to indicate both forward and rearward the presence of industrial
equipment which normally travel at rates of speed below that of other traffic.
4. General Requirements
4.1 The lamp shall comply in both the forward and rearward direction with the candela requirements of a turn
signal lamp, SAE J588, Table 1. In addition, the lamp shall project at least 4 cd on both sides at 90 deg to the
lamp axis.
4.2 The color of the light from the warning lamp shall be amber in accordance with SAE J578.
4.3 The lamp shall be flashed at least 60 fpm (flashes per minute) but not more than 120 fpm when it is operating.
SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely
voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.”
SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.
4.4 The effective projected illuminated area measured on a plane at right angles to the axis of the lamp shall not be
less than 12 in2 (77.5 mm2).
5. Test Requirements—The flashing warning lamp shall be tested according to the following sections of SAE
J575:
-2-
SAE J96 Reaffirmed MAR86
Rationale—Not applicable.
Application—This SAE Standard covers the general requirements and the test requirements for a flashing
warning lamp for industrial wheeled equipment.
Reference Section
SAE J588—Turn Signal Lamps for Use on Motor Vehicles Less Than 2032 mm in Overall Width