Chlor Alkali Valve Figure Numbers Based On Chlorine Institute Pamphlet 6 Valve Service Table
Chlor Alkali Valve Figure Numbers Based On Chlorine Institute Pamphlet 6 Valve Service Table
Chlor Alkali Valve Figure Numbers Based On Chlorine Institute Pamphlet 6 Valve Service Table
jamesbury
Chlorine
Chlor Alkali Valve Figure Numbers
Based on Chlorine Institute Pamphlet 6
Valve Service Table
BALL VALVES BUTTERFLY VALVES
Service
Class
Class 150 Class 300 Thd End Weld End Class 150 Class 300
Bulletin B107-1 Bulletin B107-2 Bulletin B101-2 Bulletin B105-1 Bulletin W101-6 Bulletin W101-6
1/2 – 10" 7150C 1/2 – 10" 7300C 1/2 – 1 1/2" 1/2 – 2" 2 1/2 – 24" 815LC 2 1/2 – 24" 830LC
Class I
31 2271 XTZ1 31 2271 XTZ1 9FAC 2271XT 4CBC 2271 XT1 11 2271 XZ 11 2271 XZ
1/2 – 10" 7150C 1/2 – 10" 7300C 1/2 – 1 1/2" 1/2 – 2" 2 1/2 – 24" 815LC 2 1/2 – 24" 830LC
31 2273 XTZ1 31 2273 XTZ1 9FAC 2273XT 4CBC 2273 XT1 11 2273 XZ 11 2273 XZ
1 – 3" 7300L1
Class II
31 2671 XTZ4
OA 1 – 3" 7300L1 OA OA OA OA
31 2673 XTZ4
(Bulletin B115-4)
1 – 3" 7300L1
Class III
31 2671 XTZ4
OA 1 – 3" 7300L1 NR NR OA OA
31 2673 XTZ4
(Bulletin B115-4)
Class IV
1/2 – 10" 7150C 1/2 – 10" 7300C 1/2 – 1 1/2" 1/2 – 2" 2 1/2 – 24" 815LC 2 1/2 – 24" 830LC
31 2271 XTZ1 31 2271 XTZ1 9FAC 2271XT 4CBC 2271 XT1 11 2271 XZ 11 2271 XZ
1/2 – 10" 7150C 1/2 – 10" 7300C 1/2 – 1 1/2" 1/2 – 2" 2 1/2 – 24" 815LC 2 1/2 – 24" 830LC
31 2273 XTZ1 31 2273 XTZ1 9FAC 2273XT 4CBC 2273 XT1 11 2273 XZ 11 2273 XZ
1 – 3" 7300L1
Class V
31 2671 XTZ4
OA 1 – 3" 7300L1 NR OA OA OA
31 2673 XTZ4
(Bulletin B115-4)
1 – 3" 7300L1
Class VI
31 2671 XTZ4
OA 1 – 3" 7300L1 NR NR OA OA
31 2673 XTZ4
(Bulletin B115-4)
Service Class Fluid State Pressure, psig Pressure, kPa Temperature, °F Temperature, °C
Class I Gas Only Vacuum to 150 Vacuum to 1034 -20 to 300 -29 to 149
Class II Gas Only Vacuum to 150 Vacuum to 1034 -50 to 300 -46 to 149
Class III Gas Only Vacuum to 150 Vacuum to 1034 -150 to 300 -101 to 149
Class IV* Gas or Liquid Vacuum to 300 Vacuum to 2068 -20 to 300 -29 to 149
Class V Gas or Liquid Vacuum to 300 Vacuum to 2068 -50 to 300 -46 to 149
Class VI Gas or Liquid Vacuum to 300 Vacuum to 2068 -150 to 300 -101 to 149
* Piping classes corresponding to the fluid state “gas or liquid” are to be used for all liquid-only lines and gas lines where the possibility of liquid entry exists or where there is
the possibility that gas in a line may liquefy.
The information provided in this bulletin is advisory in nature, and is intended as a guideline only.
For specific circumstances and more detailed information, please consult with Metso.