0% found this document useful (0 votes)
89 views

7 Segment Display Unit D1SC-N/D1SA Series

This document provides information on the D1SC-N/D1SA Series 7 Segment Display Unit. It features a large, high bright LED 7 segment display in red or green. It can display decimal numbers from 0 to 9 or hexadecimal numbers from 0 to 9 and A to F. The display unit accepts either serial or parallel data input and has configurable input logic and decimal point settings. It is suited for applications like PLC displays, computer displays, and various industrial displays.

Uploaded by

azisrosidi123
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views

7 Segment Display Unit D1SC-N/D1SA Series

This document provides information on the D1SC-N/D1SA Series 7 Segment Display Unit. It features a large, high bright LED 7 segment display in red or green. It can display decimal numbers from 0 to 9 or hexadecimal numbers from 0 to 9 and A to F. The display unit accepts either serial or parallel data input and has configurable input logic and decimal point settings. It is suited for applications like PLC displays, computer displays, and various industrial displays.

Uploaded by

azisrosidi123
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

D1SC-N/D1SA Series 7 Segment Display Unit

7 Segment Display Unit large(W32×H57mm) and high bright LED (A)


Photo
electric

Features sensor

(B)
● Selectable decimal(0 to 9) or hexadecimal(0 to 9, A to F) Fiber
optic
indication code sensor

Selectable positive or negative input logic (C)


Door/Area
Selectable serial or parallel data input method sensor

● 7 Segment, red/green display (D1SA Series)


(D)
● Power source: 12-24VDC Proximity
sensor
● Wide range on signal input voltage level
(Low: Max. 0-1.2VDC, High: 4.5-24VDC) (E)
Pressure
● Easy multi-stages connection (D1SA Series) sensor
D1SC-N
● Zero Blanking function
(F)
Rotary

Applications encoder

● Display for PLC (G)


Connector/
● Display for computer Socket

● Various display (H)


Temp.
controller
Please read “Caution for your safety” in operation
manual before using.
(I)
SSR/
Power
D1SA Sereis controller

(J)
Specifications Counter

※1
Model D1SC-N D1SA-RN D1SA-GN
(K)
Display method 7 Segment LED display(red) 7 Segment LED display(green) Timer

Power supply 12-24VDC


(L)
Allowable voltage range 90 to 110% of rated voltage Panel
meter
Current consumption Max. 70mA Max. 35mA
(M)
Character size W32 × H57mm W11×H22mm Tacho/
Speed/ Pulse
※2 meter
Display character • Decimal number : 0 to 9, decimal point • Hexadecimal number : 0 to 9, A to F, decimal point
• Parallel : Parallel 4bit data, latch, zero blanking, decimal point (N)
Display
Input • Serial : Serial 4bit or 5bit data, clock, zero blanking, latch, unit
decimal point(for 4 bit input)
Input resistance 12kΩ 20kΩ (O)
Sensor
controller
Input level High : 4.5-24VDC, Low : 0-1.2VDC
Max. response CLOCK Max. 3kHz (P)
Switching
mode power
Output Data output (serial input), zero blanking output supply

Selectable positive logic (PNP) or negative logic (NPN) (Q)


Input logic
(D1SC-N: by the function set switch, D1SA Series: by inner soldering) Stepper
motor&
Driver&Controller
Noise strength ±300V the square wave noise (pulse width: 1us) by the noise simulator
Environ Ambient temperature 0 to 60℃, storage : -10 to 85℃
(R)
Graphic/
Logic
-ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH panel

Housing[5264-10], (S)
Accessory Terminal[5263(PBT)], Sub-PCB for Connector(CT-10S), Cap Field
network
multi-stage connection device

Unit weight Approx. 100g Approx. 22g(including right/left caps)


(T)
Software
※1: It is option
※2: Only D1SC-N supports Minus displaying.
※The max. response CLOCK is when the duty ratio is 1:1. (U)
Other
※Environment resistance is rated at no freezing or condensation.

N-21
D1SC-N/D1SA Series

Terminal layout and function


D1SC-N ① Function set jumper(SW1)

OFF
ON CN2
SW1 1

ON OFF <Factory default>

ON OFF 10 ON OFF Function


②5 SW2 Pos. logic(NPN) Neg. logic(PNP) Input logic
JP1 1

Jumper
1 10
CN1
(rear terminal layout)
Jumper pin
② Function set switches(SW2, JP1)
ON
ON OFF
③ Input/Output terminals
1 2 3 45

JP1 Input Parallel input Serial input


Terminal Code Function Code Function
ON

<Factory default>
1 V+ 12-24VDC VCC 12-24VDC
No. ON OFF Function 2 D0 N·C Do not connect anything
1 Decimal Hexadecimal Characters 3 D1 CK Clock input
Data input
2 Parallel Serial Input 4 D2 DI Data input
SW2 3 4Bit 5Bit Serial input 5 D3 DO Data output
※1
4 Used Not used Serial data output 6 BI Zero blanking input BI Zero blanking input
5 Used Not used Zero Blanking 7 BO Zero blanking output BO Zero blanking output
8 LE Latch input LE Latch input
JP1 Minus
9 DP Decimal point input DP Decimal point input
7Segment Minus
※1: For Serial input, set this as ON.
10 GND 0V GND 0V
For Parallel input, set this as OFF. ※Terminals of CN1 and CN2 is corresponding 1:1.

D1SA Series
① Function set switches
No. ON OFF Function
S1 Decimal Hexadecimal Characters
S2 Parallel Serial Input
① S3 4Bit 5Bit Serial input
※1
S4 J2 J1 S3 S2 S1 J1 Used Not used Serial data output
J2 Used Not used Zero Blanking

S4 Neg. logic(NPN) Pos. logic(PNP) Input logic
<Factory default> ※1: For Serial input, set this as ON. For Parallel input, set this as OFF.

※ON = (Short) OFF = (Open)

② Input/Output terminals
Input Parallel input Serial input
10 Terminal Code Function Code Function
9 1 V+ 12-24VDC VCC 12-24VDC
8 2 D0 N·C Do not connect anything
7 3 D1 CK Clock input
Data input
6 4 D2 DI Data input
5 5 D3 DO Data output
4 6 BI Zero Blanking input BI Zero Blanking input
3 7 BO Zero Blanking output BO Zero Blanking output
2 8 LE LATCH input LE LATCH input
1 9 DP Point input DP Point input
10 GND 0V GND 0V

N-22
7 Segment Display Unit

Block diagram (A)


Photo
electric
Parallel input sensor

(B)
V+ Stablize Fiber
Power power
optic
GND sensor

D0 (C)
DataD1 Door/Area
sensor
input
D2 Input DECODER
Input circuit
D4 circuit DRIVER (D)
LATCH - LE Proximity
sensor
Decimal point -DP
(E)
Pressure
sensor
Zero blanking input - BI Input circuit
Input circuit Zero blanking
Zero blanking output - BO control circuit (F)
Rotary
encoder

Serial input (G)


Connector/
V+ Stablize Socket
Power power
GND
(H)
CLOCK - CK Temp.
controller
Data input - DI Input DECODER
Input circuit
LATCH - LE circuit DRIVER (I)
SSR/
Decimal point - DP Power
controller
Data output - DO
(J)
Counter
Zero blanking input - BI Input circuit
Input circuit Zero blanking
Zero blanking output - BO control circuit
(K)
Timer
※The ② pin is not used.

(L)

Dimensions (unit: mm)


Panel
meter

D1SC-N ● Panel cut-out (M)


Tacho/
72 2.3 25.7 72×N-3.5 Speed/ Pulse
meter
※N: Number of units
32 ※Panel thickness: 2 to 4mm (N)
Display
unit

(O)
Sensor
controller
90.5
90
57

96

(P)
Switching
mode power
supply

(Q)
Stepper
motor&
Driver&Controller
10°
(R)
Accessories Graphic/
Logic
■ CN1 : Connector specification ■ CN2 : Connector for multi-stage panel

● Connector maker: Korea Morex ● This connector must be used with (S)
Field
OFF • Housing: 5264-10 connection PCB network
ON • Header: 5264-10A(Straight) device
● CN1 and CN2 must be connected as
SW1
• Terminal: 5263(PBT) below drawing. (T)
● Using cable specification 8mm Software
CN2
• AWG28 to 22(cable diameter: Max. Ø1.9mm)
• Shielding length of wire cover: 2.4 to 2.9mm (U)
Other

CN1
27mm

Header
Housing[5264-10] Terminal[5263(PBT)]
Multi-stage connector

N-23
D1SC-N/D1SA Series
D1SA Series (unit: mm)
6 ● Panel cut-out

31
33
B
A
● Panel cut-out chart
3.5 54
Digit(N) A(20×N+12) B(20×N+10)
11 35 1 32 30±0.1
2 52 50±0.1
3 72 70±0.1
4 92 90±0.1
22

5 112 110±0.1
6 132 130±0.1
7 152 150±0.1
8 172 170±0.1

Accessory Sold separately


● Connector(Model : CT-10S) ● CAP
19
13.5
7.5 2-Ø3.4 7.5
7.5

● D1SA-RN: DAR(L) -R (left/right 1 set)


● D1SA-GN: DAR(L) -BL (left/right 1 set)
※Cap is optional (1set).
42
37

23
32

Input data chart


Indication Negative input Positive input
※1
Minus 7 Segment
Hexa Hexa D C B A D C B A
Decimal Decimal
decimal decimal
Blank Blank H H H H L L L L
Blank Blank H H H L L L L H
H H L H L L H L
H H L L L L H H
H L H H L H L L
H L H L L H L H
H L L H L H H L
Blank Blank H L L L L H H H
L H H H H L L L
※When BI terminal connect GND, “0” is
displayed. When BI terminal is open, it is
L H H L H L L H blank (not display)
Blank Blank L H L H H L H L ※"X" : Either high or low level can be input.
※1: Only D1SC-N supports Minus display.
Blank Blank L H L L H L H H Set the rear JP1 as OFF.
Blank Blank Blank L L H H H H L L ※Blank: If input signal as input DATA, it does
not display.
Blank Blank L L H L H H L H
Blank Blank L L L H H H H L
Blank Blank L L L L H H H H

N-24
7 Segment Display Unit

Input circuit (A)


Photo
electric
D1SC-N sensor

● Positive logic(PNP) input (SW1: OFF) ● Negative logic(NPN) input (SW1: ON) (B)
Fiber
optic
sensor
+5V
10kΩ 20kΩ
(C)
Input IC Door/Area
12kΩ sensor

12kΩ 10kΩ 20kΩ


Input IC (D)
Proximity
sensor

(E)
Pressure
※Input level - High : 4.5-24VDC, Low: 0-1.2VDC sensor

D1SA Series (F)


Rotary

● Positive logic(PNP)input (SW1: OFF) ● Negative logic(NPN) input (SW1: ON) encoder

(G)
100kΩ 5V Connector/
Socket
Input IC
20kΩ (H)
Temp.
20kΩ 100kΩ controller

※Input level High : 4.5-24VDC Input IC


(I)
Low: 0-1.2VDC SSR/
Power
controller

Data input method (J)


Counter

Parallel input
● 4Bit Static Parallel input(ex: displays ABCD.) (K)
Timer

103 102 101 100 4Bit Data3+Point3 HLHL+L


(L)
Panel
4Bit Data2+Point2 HLHH+L meter

4Bit Data1+Point1 HHLL+L (M)


4Bit Data3+Point3 Tacho/
4Bit Data0+Point0 HHLH+H Speed/ Pulse
4Bit Data2+Point2 meter
LATCH
4Bit Data1+Point1 (N)
Display
4Bit Data0+Point0 unit

LATCH
(O)
Sensor
103 102 101 100 controller

● 4Bit Dynamic Parallel input(ex: displays ACE007.) ※Clock: Max. 3kHz (P)
Pw Switching
mode power
105 104 101 100 4Bit supply
HLHL HHLL HHHL LLLL LLLL LHHH
Data
(Q)
Point Stepper
motor&
LATCH 5 Driver&Controller
LATCH 4
4Bit Data t1 t2 t3 (R)
Graphic/
Point LATCH 3 Logic
panel
LATCH 5 LATCH 2
LATCH 4 LATCH 1 (S)
Field
LATCH 0 network
device
LATCH 1
LATCH 0 (T)
Software
0
10 5
104 103 10 2
10 1
10
(U)
※Pw=t1+t2+t3 Other
Pw: 0.33ms(Min.)
t1: 0.05ms(Min.) → Data LATCH
t2: 0.23ms(Min.) → Data move
t3: 0.05ms(Min.) → Data

N-25
D1SC-N/D1SA Series
Serial input ※Clock max. 3kHz
● 6Bit Serial input(ex: displays -20.8) ※In case of positive logic (PNP), hexadecimal number

ta: 0.23ms(Min.)
START tw: 0.05ms(Min.)
tw
LATCH
SHIFT 0.33ms ta

CLOCK

1Bit Data L L H L L L H L L L L L H L L L
D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0 D3 D2 D1 D0
LSB(3P)
MSB(3)

MSB(2)

MSB(1)

MSB(0)
LSB(2)

LSB(1)

LSB(0)
Data Data Data Data

※1 ※2

※1: To display Minus, set the rear JP1 as OFF.


※2: In case of 4Bit Serial input, to display decimal point, connect DP of the rear input terminal to V+.
In case of negative logic(NPN), connect DP to GND.

● 5Bit SeriaI input(ex: displays A25.0)


ta: 0.23ms(Min.)
START tw: 0.05ms(Min.)
tw
w
LATCH
SHIFT 0.33ms ta
a
CLOCK

1Bit Data L H L H L L L L H L H L H L H L L L L L
D4 D3 D2 D1 D0 D4 D3 D2 D1 D0 D4 D3 D2 D1 D0 D4 D3 D2 D1 D0
LSB(3P)

MSB(2)

MSB(1)

MSB(0)
MSB(3)

LSB(2)

LSB(1)

LSB(0)
Point

Point

Point

Point

Data Data Data Data

Multi-stage connection method


Parallel input : 4digit
※The below connection is example of D1SC-N. Fro D1SA, connection is same but the order of pin is reverse.
(connector image(refer to N-14 page of the 9th catalogue)
※CN1, CN2 terminals of D1SC-N corresponds 1:1 and it is able to connect as CN1 depending on the need.
※When not using Zero Blanking, connect BI terminal to GND.

● Static parallel input(Zero blanking method): These diagrams are to wire at rear layout of the unit.
DP DP DP DP

D3 D3 D3 D3

D2 D2 D2 D2
Data
input
D1 D1 D1 D1

D0 D0 D0 D0

CN2 CN2 CN2 CN2


1 1 1 1
V+ V+ V+ V+
V+
D0 D0 D0 D0
D1 D1 D1 D1
D2 D2 D2 D2 From next digit
D3 D3 D3 D3 (over 5digits)
BI BI BI BI
BO
BO BO BO BO
LE LE LE LE
LATCH
DP DP DP DP
GND GND GND GND
GND
10 10 10 10
1 10 1 10 1 10 1 10
CN1 CN1 CN1 CN1

100 101 102 103

N-26
7 Segment Display Unit
● Dynamic parallel input(Zero blanking method) : These diagrams are to wire at rear layout of the unit. (A)
Photo
LATCH 0 electric
sensor
LATCH 1
Data (B)
LATCH 2 Fiber
input
optic
LATCH 3 sensor

CN2 1 CN2 1 CN2 1 CN2 1 (C)


V+ V+ V+ V+ Door/Area
V+ sensor
D0 D0 D0 D0
D0
D1 D1 D1 D1
D1
D2 D2 D2 D2 (D)
D2
D3 D3 D3 D3 Proximity
D3 sensor
BI BI BI BI
BO
BO BO BO BO
From next digit
LE LE LE LE
(over 5digits) (E)
DP DP DP DP Pressure
DP sensor
GND GND GND GND
GND
10 10 10 10
1 10 1 10 1 10 1 10 (F)
CN1 CN1 CN1 CN1 Rotary
encoder
0 1 2 3
10 10 10 10
(G)
Connector/
Serial input : 4digit Socket

● Serial input (Zero blanking method) : These diagrams are to wire at rear layout of the unit. (H)
DI Temp.
controller
Data input
CN2 CN2 CN2 CN2
1 1 1 1 (I)
SSR/
VCC VCC VCC VCC
VCC Power
controller
CK CK CK CK
CK
DI DI DI DI
DO
From next digit (J)
DO DO DO
(over 5digits) Counter
BI BI BI BI
BO
BO BO BO BO
LE LE LE LE
DP
LATCH (K)
DP DP DP
Timer
GND GND GND GND
GND
1 10 10 1 10 10 1 10 10 1 10 10
(L)
CN1 CN1 CN1 CN1 Panel
meter
100 101 102 103
(M)
Tacho/

Zero blanking method? Speed/ Pulse


meter

It is to remove "0" indication which is no meaning. (N)


Ex1) When displaying 10 Display
unit
① Using Zero Blanking ② Not using Zero Blanking
(O)
("0" of 103, 102 are no meaning Sensor
controller

103 102 101 100 and they are not displayed.) 103 102 101 100 (P)
※If indication data is "101", meaningful tens place "0" will be displayed. Switching
mode power
supply

Using Zero Blanking for multi-stage (Q)


Stepper
motor&
Set no.5 (Zero Blanking output) of the rear function set switch(SW2) as ON. Driver&Controller

For 10(0) to display '0', set this as OFF. (R)


1) Using Zero Blanking Graphic/
Logic
panel
V+
(S)
Field
network
device
BI BO BI BO BI BO BI BO
3 2 1 0
10 10 10 10 (T)
Software
3 2 1 0
10 10 10 10
GND
2) Not using Zero Blanking (U)
Other

BI BO BI BO BI BO BI BO
3 2 1 0
10 10 10 10
103 102 101 100
GND GND

N-27
D1SC-N/D1SA Series

The application of PLC program[Serial input type]


1. Display Unit D1SA-
2. Data input type: Serial
3. Connection type: See serial connection type when using more than 2EA
4. Display result: "A" Display
5. PLC: LSIS(LS Industrial Systems), MASTER-K Series
6. When using serial type, use transistor output card of PLC
7. Negative logic(NPN)

P000
[ SET S00.01 ]
M000
[ SET S00.02 ]
M001
[ SET S00.03 ]
M000
[ SET S00.04 ]
M001
[ SET S00.05 ] Shift register
M000
[ SET S00.06 ]
M001
[ SET S00.07 ]
M000
[ SET S00.08 ]
M001
[ SET S00.09 ]
S00.09 M000
[ SET S00.00 ] Reset

S00.01
( M000 )
S00.03

S00.05

S00.07

S00.09

S00.02
(M001)
S00.04

S00.06

S00.08

S00.02
(P010) CLOCK output
S00.04

S00.06

S00.08

P000 HEX "A" value


( MOV h000A M01 ) Transmission order
to M01
S00.01 M013
(P011) HEX "A" value
data output
S00.02
"A" display
S00.03 M012

S00.04

S00.05 M011

S00.06

S00.07 M010

S00.08

S00.09
(P012) LATCH Output

[ END ]

※Visit our web site(www.autonics.com) to download various applications of PLC program.

N-28

You might also like