PRCM Series Catalogue EN
PRCM Series Catalogue EN
PRCM Series Catalogue EN
Specifications
● DC 2-wire type
PRCMT12-2DO PRCMT12-4DO PRCMT18-5DO PRCMT18-8DO PRCMT30-10DO PRCMT30-15DO
PRCMT12-2DC PRCMT12-4DC PRCMT18-5DC PRCMT18-8DC PRCMT30-10DC PRCMT30-15DC
Model
PRCMT12-2DO-I PRCMT12-4DO-I PRCMT18-5DO-I PRCMT18-8DO-I PRCMT30-10DO-I PRCMT30-15DO-I
PRCMT12-2DC-I PRCMT12-4DC-I PRCMT18-5DC-I PRCMT18-8DC-I PRCMT30-10DC-I PRCMT30-15DC-I
Diameter of
12mm 18mm 30mm
sensing side
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm
Non-shield Non-shield Non-shield
Installation Shield (flush) Shield (flush) Shield (flush)
(non-flush) (non-flush) (non-flush)
Hysteresis Max. 10% of sensing distance
Standard sensing
12×12×1mm (iron) 18×18×1mm (iron) 25×25×1mm (iron) 30×30×1mm (iron) 45×45×1mm (iron)
target
Setting distance 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply 12-24VDCᜡ
(operating voltage) (10-30VDCᜡ)
Leakage current Max. 0.6mA
Response
1.5kHz 500Hz 350Hz 400Hz 200Hz
frequency※1
Residual voltage Max. 3.5V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃
Control output 2 to 100mA
Insulation resistance Over 50MΩ (at 500VDC megger)
Dielectric strength 1,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z directions for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z directions for 3 times
Indicator Operation indicator: Red LED
Ambient
-25 to 70℃, storage: -30 to 80℃
Environ- temperature
ment Ambient
35 to 95%RH, storage: 35 to 95%RH
humidity
Protection circuit Surge protection circuit, output short over current protection circuit
Protection structure IP67 (IEC standard)
Material Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate
Approval ᜢ
Weight※2 Approx. 38g (approx. 26g) Approx. 60g (approx. 48g) Approx. 154g (approx. 142g)
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※2: The weight includes packaging. The weight in parenthesis in for unit only.
※There is IEC standard connector cable.
For more information about cable and specification, refer to the (I) Connectors/Cable Connectors/Sensor Distribution Boxes/Sockets
※Environment resistance is rated at no freezing or condensation.
F-90
Cylindrical Connector type
Specifications
● DC 3-wire type SENSORS
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard (I)
sensing target, 1/2 of the sensing distance for the distance. Connectors/
Connector Cables/
※2: The weight includes packaging. The weight in parenthesisa in for unit only. Sensor Distribution
※Environment resistance is rated at no freezing or condensation. Boxes/ Sockets
F-91
PRCM Series
● AC 2-wire type
PRCM18-5AO PRCM18-8AO PRCM30-10AO PRCM30-15AO
PRCM12-2AO PRCM12-4AO PRCM18-5AC PRCM18-8AC PRCM30-10AC PRCM30-15AC
Model
PRCM12-2AC PRCM12-4AC PRCML18-5AO PRCML18-8AO PRCML30-10AO PRCML30-15AO
PRCML18-5AC PRCML18-8AC PRCML30-10AC PRCML30-15AC
Diameter of
12mm 18mm 30mm
sensing side
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm
Non-shield Non-shield Non-shield
Installation Shield (flush) Shield (flush) Shield (flush)
(non-flush) (non-flush) (non-flush)
Hysteresis Max. 10% of sensing distance
18×18×1mm 25×25×1mm 30×30×1mm 45×45×1mm
Standard sensing target 12×12×1mm (iron)
(iron) (iron) (iron) (iron)
Sensing distance 0 to 1.4mm 0 to 2.8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
Power supply 100-240VACᜠ
(operating voltage) (85-264VACᜠ)
Leakage current Max. 2.5mA
Response frequency※1 20Hz
Residual voltage Max. 10V
Affection by Temp. Max. ±10% for sensing distance at ambient temperature 20℃
Control output 5 to 150mA 5 to 200mA
Insulation resistance Over 50MΩ (at 500VDC megger)
Dielectric strength 2,500VAC 50/60Hz for 1 min
Vibration 1mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z directions for 2 hours
Shock 500m/s² (approx. 50G) in each X, Y, Z directions for 3 times
Indicator Operation indicator: Red LED
Ambient
Environ- -25 to 70℃, storage: -30 to 80℃
temperature
ment
Ambient humidity 35 to 95%RH, storage: 35 to 95%RH
Protection circuit Surge protection circuit
Protection structure IP67 (IEC standard)
Double insulation or reinforced insulation
Insulation type
(Mark: , dielectric strength between the measuring input part and the power part: 1kV)
Material Case/Nut: Nickel plated brass, Washer: Nickel plated iron, Sensing surface: Polybutylene terephthalate
Approval ᜢ
PRCM: Approx. 66g (approx. 54g) PRCM: Approx. 154g (approx. 142g)
Weight※2 Approx. 42g (approx. 30g)
PRCML: Approx. 78g (approx. 66g) PRCML: Approx. 194g (approx. 182g)
※1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
※2: The weight includes packaging. The weight in parenthesis in for unit only.
※Environment resistance is rated at no freezing or condensation.
F-92
Cylindrical Connector type
Dimensions (unit: mm)
● PRCM12-2D / PRCMT12-2D (-I) ● PRCM12-4D / PRCMT12-4D (-I)
Ø21 55.8 Ø21 55.8 SENSORS
17 31.5 Operation
17 7 24.5 Operation
indicator
indicator
CONTROLLERS
4 M18×1 M12
4 M18×1 M12
(B)
Fiber Optic
Sensors
(E)
Vision
4 M12×1 M12 4 M12×1 M12 Sensors
M12 M12
5 M30×1.5 5 M30×1.5
F-93
PRCM Series
Control Output Diagram and Load Operation
DC 2-wire type DC 3-wire type
Brown NPN output type
N.O. N.C.
4 Load +V Presence Brown N.O. N.C.
Sensing 1 +V
target Nothing Sensing Presence
target None
Main circuit
Load
Main circuit
10kΩ Load Operation
Operation
Load (brown-black) Return
Return Black
4
Output voltage H
Operating ON (black-blue) L
Blue Indicator Operating
3 0V (red LED) OFF Blue ON
3 0V Indicator
(red LED) OFF
AC 2-wire type
Brown N.O. N.C. PNP output type
4 Load Sensing Presence Brown N.O. N.C.
target None 1 +V
Sensing Presence
target None
100- 240VAC
Main circuit
Main circuit
Black Load Operation
50/60Hz Operation 4 (black-blue)
Load Return
Return
Load Output voltage H
10kΩ (black-blue) L
Blue
3 Operating ON
Indicator Operating ON
Blue
(red LED) OFF 3 0V Indicator
OFF
(red LED)
Wiring Diagram
DC 2-wire type (standard type) DC 2-wire type (IEC standard type)
Normally Open (N.O.) / Normally Closed (N.C.) Normally Open (N.O.) Normally Closed (N.C.)
Brown Brown
2 1 Brown 2 1 2 1 Load +V 2 1 Load +V
Brown
3 4 Load +V 3 4 +V 3 4 3 4
Blue Blue Blue Blue
0V Load 0V 0V 0V
※Pin ①, ② are not used terminals. ※②,③ of N.O. type and ③,④ of N.C. type are not used
※For DC 3-wire type connector cable, it is available to use terminals.
with black wire (12-24V DC) and blue wire (0V). ※The pin arrangement of connector applying IEC standard is
being developed.
※Please attach "I" at the end of the name of standard type
for purchasing the IEC standard product.
E.g.) PRCMT12-4DO-I
※The connector cable for IEC standard is being developed.
Please attach "I' at the end of the name of standard type.
E.g.) CID2-2-I, CLD2-5-I
Brown Brown
2 1 +V 2 1 +V
2 1 2 1
Black Brown Brown
3 4 Load 3 4 3 4 3 4
Load
Black Load ~
~ Blue
Blue Blue Blue Load
0V 0V
※Please fasten the cleat of connector not to shown the ※In AC inductive type, ② and ③, ① and ④ are connected
thread. (0.39 to 0.49N.m) inside of the connector cable.
F-94
Cylindrical Connector type
Sensing Distance Feature Data by Target Material and Size
One side
SENSORS
Sensing
length
target
d
Detecting
Method
Sensing
distance (X)
CONTROLLERS
4.00 Iron(SS401)
4.00 6.00
Stainless steel 364 (E)
Stainless steel 364 (SUS364) Vision
5.00 Sensors
(SUS364)
3.00
4.00
Brass(C3601)
(F)
2.00 3.00 Aluminum(ALS052) Proximity
Brass(C3601) Copper(C1100) Sensors
Aluminum(ALS052)
Copper(C1100) 2.00
1.00
1.00 (G)
Pressure
Sensors
0.00 0.00
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100 4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
One side length of sensing target d (mm) One side length of sensing target d (mm) (H)
Rotary
Encoders
(I)
PRCMT30-10D , PRCM(L)30-10A PRCMT30-15D , PRCM(L)30-15A Connectors/
Connector Cables/
Sensor Distribution
12.00 16.00 Boxes/ Sockets
Iron(SS401)
Iron(SS401) 14.00
10.00
12.00
Sensing distance X (mm)
2.00
2.00
0.00 0.00
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100 4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
One side length of sensing target d (mm) One side length of sensing target d (mm)
F-95
PRCM Series
Sensing Distance Feature Data by Target Material and Size
One side
Sensing
length
target
d
Detecting
Method
Sensing
distance (X)
PRCM(L)12-2D PRCM12-4D
2.50 5.00
4.50
Iron(SS401)
2.00 Iron(SS401) 4.00
Sensing distance X (mm)
0.50
0.00 0.00
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100 4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
One side length of sensing target d (mm) One side length of sensing target d (mm)
PRCM(L)18-5D PRCM(L)18-8D
6.00 9.00
Iron(SS401)
8.00
Iron(SS401)
5.00
7.00
Sensing distance X (mm)
0.00 0.00
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100 4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
One side length of sensing target d (mm) One side length of sensing target d (mm)
PRCM(L)30-10D PRCM(L)30-15D
12.00 18.00
16.00 Iron(SS401)
10.00 Iron(SS401)
14.00
Sensing distance X (mm)
Sensing distance X (mm)
0.00 0.00
4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100 4 8 10 12 15 18 20 25 30 35 40 45 50 60 70 75 80 90 100
One side length of sensing target d (mm) One side length of sensing target d (mm)
F-96
Cylindrical Connector type
Sensing
distance (X)
Method SENSORS
Sensing
CONTROLLERS
P
RCMT12-2D /4D , P
RCMT18-5D /8D , P RCMT30-10D /15D ,
PRCM12-2A /4A PRCM(L)18-5A /8A PRCM(L)30-10A /15A MOTION DEVICES
14.0
3.0 6.0
2.5
12.0
2.0 5.0
Sensing distance X (mm)
1.7 10.0
(A)
1.5 4.0 Photoelectric
Sensors
1.3 8.0
(B)
1.0 3.0 Fiber Optic
Sensors
6.0
0.7
(C)
0.5 2.0 LiDAR
4.0
0.4
(D)
Door/Area
0.1 1.0 2.0 Sensors
4.0 3.0 2.0 1.0 0.0 0.5 1.0 1.5 2.0 8.0 6.0 4.0 2.0 0.0 2.0 4.0 6.0 8.0 20.0 15.0 10.0 5.0 0.0 5.0 10.0 15.0 20.0
Left ← Center → Right Left ← Center → Right Left ← Center → Right
Sensing area Y (mm) Sensing area Y (mm) Sensing area Y (mm) (E)
Vision
Sensors
(I)
3.5 Connectors/
Connector Cables/
14.0 Sensor Distribution
3.0 6.0 Boxes/ Sockets
2.5
12.0
2.0 5.0
1.7 10.0
Sensing distance X (mm)
Sensing distance X (mm)
1.5 4.0
1.3 8.0
1.0 3.0
6.0
0.7
0.5 2.0
4.0
0.4
F-97
PRCM Series
Proper Usage
Load connections
Brown Brown Brown
Load Load
+ + 100-
POWER 24VDC 240VAC
- - 50/60Hz
Blue Blue Blue
Load Load
< DC 2-wire type & AC 2-wire type > < DC 2-wire type > < AC 2-wire type >
When using DC or AC 2-wire type proximity sensor, the load must be connected, otherwise internal components may be
damaged. The load can be connected to either wire.
Load connections
● AC 2-wire type It may cause return failure of load by residual voltage.
If the load current is under 5mA, please make sure the
Brown
Load residual voltage is less than the return voltage of the load
by connecting a bleeder resistor in parallel with the load as
Bleeder resistor(R) Vs shown in the diagram.
Blue
Vs Vs2
110VAC: Min. 20kΩ 3W R≤ (kΩ) P> (W)
220VAC: Min. 39kΩ 10W
I R
[I: Action current of load, R: Bleeder resistance, P: Permissible power]
Please make the current on proximity sensor smaller than
● DC 2-wire type
Brown the return current of load by connecting a bleeder resistor
Load in parallel.
+ ※W value of Bleeder resistor should be bigger for proper
Bleeder resistor(R) Vs
- heat dissipation.
Blue
Vs Vs2
R≤ (kΩ) P> (W)
Io-Ioff R
Io: Min. action current of proximity sensor,
[ Vs: Power supply,
Ioff: Return current of load, P: Number of Bleeder resistance watt
]
Parallel B
A
Face to Face
When sensors are mounted on metallic panel, it is required to protect the sensors from being affected by any metallic
object except target. Therefore, be sure to provide a minimum distance as below chart indicates.
Ød n
ℓ
ℓ
ℓ
(unit: mm)
Model
PRCMT12-2D□ PRCMT12-4D□ PRCMT18-5D□ PRCMT18-8D□ PRCMT30-10D□ PRCMT30-15D□
PRCM12-2D□ PRCM12-4D□ PRCM(L)18-5D□ PRCM(L)18-8D□ PRCM(L)30-10D□ PRCM(L)30-15D□
PRCM12-2A□ PRCM12-4A□ PRCM(L)18-5A□ PRCM(L)18-8A□ PRCM(L)30-10A□ PRCM(L)30-15A□
Item
A 12 24 30 48 60 90
B 24 36 36 54 60 90
ℓ 0 11 0 14 0 15
Ød 12 36 18 54 30 90
m 6 12 15 24 30 45
n 18 36 27 54 45 90
F-98