Ac, Ac-At: Vishay Draloric
Ac, Ac-At: Vishay Draloric
Ac, Ac-At: Vishay Draloric
www.vishay.com
Vishay Draloric
Cemented Leaded Wirewound Resistors
FEATURES
• AEC-Q200 qualified AC-AT series
• High power dissipation in small design
• Non-flammable coating conforming to
UL 94 V-0
• Excellent pulse load capability
• Non-inductive (NI) version available
• WSZ-form lead bending available for SMD mounting
• Material categorization: for definitions of compliance
The AC series is the perfect choice for general purpose please see www.vishay.com/doc?99912
power applications. The AEC-Q200 qualified AC-AT series
is best suited for automotive applications. The robust silicon
cement coating can handle challenging ambient and APPLICATIONS
operating conditions. Typical applications include but are
not limited to energy meters, power supplies and • Automotive electronics
automotive electronics. For a given application, • Industrial electronics
requirements of ohmic value, rated power, peak voltage, • Power supplies
pulse shape, pulse duration, lead bending, and
environmental conditions may be submitted to recommend • White goods
the most suitable product. • Pre-charged applications
Various lead forms are available such as RT (radial taped),
WSZ (Z-form), DK (double kink), EK (single kink) with defined
mounting pitch.
A C 0 3 A T 0 0 0 1 5 0 9 J A C 0 0
AC03 15R 5% AC
AC03-AT 15R 5% AC
Note
(1) For special windings or the non-inductive versions, please contact: [email protected]
PACKAGING
TYPE / SIZE CODE DESCRIPTION QUANTITY PACKAGING STYLE WIDTH PITCH DIMENSIONS
Note
(1) Manufacturing at different production locations may involve use of differently sized box
Notes
(1) Other cleaning solvents with aggressive chemicals should be evaluated in actual cleaning process for their suitability
(2) The IEC 62474 list of declarable substances is maintained in a dedicated database, which is available at http://std.iec.ch/iec62474
(3) The Global Automotive Declarable Substance List (GADSL) is maintained by the American Chemistry Council and available at www.gadsl.org
(4) The SVHC list is maintained by the European Chemical Agency (ECHA) and available at http://echa.europa.eu/candidate-list-table
Pˆ max. (W)
R10
tp/ti = 1000 1R0
1000 1R0 1000 tp/ti = 200 10R
P
ˆ
R10 110R
tp/ti = 200 10R 4K7
100R tp/ti = 50
100 2K0 100
tp/ti = 50
tp/ti = 10
tp/ti = 10
10 10 tp/ti = 2
tp/ti = 2
1 1
10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 10-5 10-4 10-3 10-2 10-1 1
ti (s) ti (s)
AC01 and AC01-AT Pulse on a regular basis; max. permissible AC03 and AC03-AT Pulse on a regular basis; max. permissible
peak pulse power ( P̂ max.) as a function of pulse duration (ti) peak pulse power ( P̂ max.) as a function of pulse duration (ti)
10 000 10 000
tp/ti = 1000
Pˆ max. (W)
max. (W)
R10 tp/ti = 1000
1R0
tp/ti = 200 tp/ti = 200
1000 10R 1000 1R1
P
ˆ
100R R10
tp/ti = 50 6K8 tp/ti = 50 11R
100R
100 100 8K2
tp/ti = 10 tp/ti = 10
tp/ti = 2 tp/ti = 2
10 10
1 1
10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 10-5 10-4 10-3 10-2 10-1 1 10
ti (s) ti (s)
AC04 and AC04-AT Pulse on a regular basis; max. permissible AC05 and AC05-AT Pulse on a regular basis; max. permissible
peak pulse power ( P̂ max.) as a function of pulse duration (ti) peak pulse power ( P̂ max.) as a function of pulse duration (ti)
10 000 10 000
tp/ti = 1000 R68
Pˆ max. (W)
Pˆ max. (W)
tp/ti = 1000
1R1 tp/ti = 200 2R2
tp/ti = 200 R10 33R
1000 11R 1000 240R
tp/ti = 50
tp/ti = 50 100R 15K
15K
tp/ti = 10
100 tp/ti = 10 100
tp/ti = 2
tp/ti = 2
10 10
1 1
10-6 10-5 10-4 10-3 10-2 10-1 1 10 10-6 10-5 10-4 10-3 10-2 10-1 1 10
ti (s) ti (s)
AC07 and AC07-AT Pulse on a regular basis; max. permissible AC10 and AC10-AT Pulse on a regular basis; max. permissible
peak pulse power ( P̂ max.) as a function of pulse duration (ti) peak pulse power ( P̂ max.) as a function of pulse duration (ti)
100 1000
Pulse Energy (Ws/Ω)
0.1 0.1
0.01
0.01
0.001
0.001
0.0001
0.0001 0.00001
0.1 1 10 100 1000 10 000 0.1 1 10 100 1000 10 000
R (Ω) R (Ω)
AC01 and AC01-AT Pulse capability; E (Ws) as a function of R () AC03 and AC03-AT Pulse capability; E (Ws) as a function of R ()
1000 1000
Pulse Energy (Ws/Ω)
100 100
10 10
1 1
0.1 0.1
0.01 0.01
0.001 0.001
0.0001 0.0001
0.1 1 10 100 1000 10 000 0.1 1 10 100 1000 10 000
R (Ω) R (Ω)
AC04 and AC04-AT Pulse capability; E (Ws) as a function of R () AC05 and AC05-AT Pulse capability; E (Ws) as a function of R ()
1000 1000
Pulse Energy (Ws/Ω)
100 100
10 10
1 1
0.1 0.1
0.01 0.01
0.001 0.001
0.0001 0.0001
0.1 1 10 100 1000 10 000 0.1 1 10 100 1000 10 000 100 000
R (Ω) R (Ω)
AC07 and AC07-AT Pulse capability; E (Ws) as a function of R () AC10 and AC10-AT Pulse capability; E (Ws) as a function of R ()
1500 2000
Vˆ max. (V)
Vˆ max. (V)
1500
1000
1000
500
500
0 0
10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 10-5 10-4 10-3 10-2 10-1 1
ti (s) ti (s)
AC01 and AC01-AT Pulse on a regular basis; max. permissible AC03 and AC03-AT Pulse on a regular basis; max. permissible
peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti)
2500 2500
Vˆ max. (V)
1500 1500
1000 1000
500 500
0 0
10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 10-5 10-4 10-3 10-2 10-1 1
ti (s) ti (s)
AC04 and AC04-AT Pulse on a regular basis; max. permissible AC05 and AC05-AT Pulse on a regular basis; max. permissible
peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti)
5000 5000
Vˆ max. (V)
Vˆ max. (V)
4000 4000
3000 3000
2000 2000
1000 1000
0 0
10-6 10-5 10-4 10-3 10-2 10-1 1 10-6 10-5 10-4 10-3 10-2 10-1 1
ti (s) ti (s)
AC07 and AC07-AT Pulse on a regular basis; max. permissible AC10 and AC10-AT Pulse on a regular basis; max. permissible
peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti) peak pulse voltage ( Vˆ max.) as a function of pulse duration (ti)
Rated Power in %
100
80
60
40
20
0
-40 0 50 100 150 200 250 300 350
40
Ambient Temperature in °C
Derating
350
Temperature Rise in K
AC10,
300 AC10-AT
250 AC07,
AC07-AT
200 AC05,
AC05-AT
150 AC04,
AC04-AT
100 AC03,
AC03-AT
50
AC01,
AC01-AT
0
0 5 10 15
Temperature Rise Power in W
L
d
x
B D
DIMENSIONS in millimeters
TYPE Lmax. Dmax. d xmax. B MASS PER UNIT (g)
AC01, AC01-AT 11.0 4.3 2 63 ± 1 0.52
AC03, AC03-AT 13.0 4.8 2 63 ± 1 0.75
AC04, AC04-AT 16.5 5.5 3 63 ± 1 1.10
0.8 ± 0.03
AC05, AC05-AT 18.0 7.5 3 63 ± 1 1.90
AC07, AC07-AT 26.0 7.5 3 73 ± 1 2.60
AC10, AC10-AT 44.0 8.0 3 88 ± 1 4.50
LEAD TERMINATION BENDING FORMS
P1 P1
L L L
ØD
Ød Ød Ød
h h h
P P2 P2
ØB ØB ØB SMAX.
ØD
Ød
AC03, AC03-AT 0.8 4.8 17 ± 0.3 11 - 12 4.8 ± 0.2 3.6 ± 0.2 5.0 ± 0.4 2.5 5.5 14.5
L1 F
L1 F
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.