100% found this document useful (1 vote)
304 views1 page

PY SEW Do P T: Pipe Wall Thickness Calculation Sheet

This document contains a pipe wall thickness calculation sheet for a project providing front-end engineering design for an effluent discharge pump improvement. It lists pipe specifications, design conditions, material properties, and calculations to determine the minimum required pipe wall thickness according to ASME B31.3 standards for various pipe sizes from 50mm to 350mm diameter to withstand a design pressure of 19.98 kg/cm2 while allowing for corrosion, mill tolerance, and weld reductions. All pipe sizes were found to have acceptable calculated thickness versus selected thickness ratios.

Uploaded by

anon_714194540
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
304 views1 page

PY SEW Do P T: Pipe Wall Thickness Calculation Sheet

This document contains a pipe wall thickness calculation sheet for a project providing front-end engineering design for an effluent discharge pump improvement. It lists pipe specifications, design conditions, material properties, and calculations to determine the minimum required pipe wall thickness according to ASME B31.3 standards for various pipe sizes from 50mm to 350mm diameter to withstand a design pressure of 19.98 kg/cm2 while allowing for corrosion, mill tolerance, and weld reductions. All pipe sizes were found to have acceptable calculated thickness versus selected thickness ratios.

Uploaded by

anon_714194540
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PIPE WALL THICKNESS CALCULATION SHEET

PROJECT No. : B710113 DOCUMENT NO. : BIF02-FIP-FEED-RNZ-000-P-CAL-0001


: PROVISION OF FRONT END ENGINEERING DESIGN (FEED) FOR BINTULU INTEGRATED FACILITIES (BIF) EFFLUENT DISCHARGE
PROJECT PUMP IMPROVEMENT FOR PETRONAS CARIGALI SDN BHD
PAGE NO. : 1 of 1

CONDITIONS : 100 % Class Condition 19.980 Kg/cm2 (g) Line Design Condition Kg/cm2 (g)

PIPE SPEC. CLASS 1C605 RATING 150 SERVICE AS PER PIPE CLASS (Note 1)
DESIGN CONDITION PRESSURE (P) 19.980 Kg/cm²(g) TEMPERATURE 35 °C 95 °F
19.600 Bar
OPERATING CONDITION PRESSURE 7.340 Kg/cm²(g) TEMPERATURE 35 °C 95 °F
3 SEAMLESS E 1.00
PIPE MATERIAL
ASTM A106 Gr.B MECHANICAL ALLOWANCE (C1) 0.00 mm
S 20000.00 psi 1406.96 Kg/cm² CORROSION ALLOWANCE (C) 3.00 mm
P * Do
DESIGN THICKNESS t= GOVERNING CODE ASME B 31.3
2( SEW + PY )
tM=t + C + C1 tR =tM / 0.875 Y 0.4 W 1.00

D/T Ratio
PIPE SIZE PIPE SIZE SCHEDULE / delta Delta = T-tR<0, then
Do t tM tR =tM / 0.875 T If D/T <100, then % of tR
D (NB) D (NB) THICKNESS (T-tR) Result = Acceptable
Result = OK
mm Inch mm mm mm mm mm
50 2.00 60.325 0.426 3.426 3.915 5.540 80 OK 161.71% 1.625 Acceptable
80 3.00 88.900 0.628 3.628 4.146 7.620 80 OK 210.05% 3.474 Acceptable
100 4.00 114.300 0.807 3.807 4.351 6.020 40 OK 158.13% 1.669 Acceptable
150 6.00 168.300 1.188 4.188 4.787 7.110 40 OK 169.76% 2.323 Acceptable
200 8.00 219.100 1.547 4.547 5.196 7.040 30 OK 154.83% 1.844 Acceptable
250 10.00 273.100 1.928 4.928 5.632 7.800 30 OK 158.27% 2.168 Acceptable
300 12.00 323.900 2.287 5.287 6.042 8.380 30 OK 158.51% 2.338 Acceptable
350 14.00 355.600 2.511 5.511 6.298 7.920 20 OK 143.72% 1.622 Acceptable

LEGENDS :
S : ALLOWABLE STRESS VALUE. P : INTERNAL DESIGN PRESSURE.
E : WELD JOINT QUALITY FACTOR.
Y : TEMPERATURE COEFFICIENT.
T : SELECTED THICKNESS
DO : OUTSIDE DIAMETER.
t : PRESSURE DESIGN THICKNESS AS PER ASME B 31.3.
tM : MINIMUM REQUIRED THICKNESS INCLUDING CORROSION ALLOWANCE.
tR : THICKNESS INCLUDING MILL TOLERANCE.
W : WELD JOINT STRENGTH REDUCTION FACTOR

NOTES :
1) OLD PIPE CLASS 11003
2) DESIGN PRESSURE (AS PER 100% CLASS CONDITION) = 19.98 Kg/cm2 (g)