GPRS Connection
GPRS Connection
TCP/IP compression (default=Disable): The setting of this field depend on whether or not the
remote user’s application requests compression.
Inactivity time (default=0 ms): This field specifies the idle time setting for auto-disconnection. A
setting of 0 ms will cause the port to remain connected even if idle.
Link quality report (default=Disable): Setting this field to Enable allows the OnCell G3100 to
disconnect a connection if the link noise exceeds a certain threshold.
Initial string: Use this field to configure the initial string that the modem will use to establish the
connection.
Username: This is the user ID account.
Password: This is the user password.
APN: Before using the GPRS, the APN (Access Point Name) must be added as a modem
initialization command. Detailed instructions are shown below.
Connection control Connect Rule Disconnect Rule GPRS
Always on/None Always on after power on None Trunk
Periodically connect/ Periodically connect (based on the Inactivity time is up Trunk
inactivity time connection interval setting) to
GPRS after powering on.
Remote host fail/ Remote Ethernet host has failed. When the remote Backup
remote host recovered The OnCell G3100 will keep Ethernet host returns
pinging the remote host over the to normal, data will
Ethernet every 3 seconds after revert to being sent
powering on. After failing to over Ethernet after 5
connect 5 times in a row, the data continuous
from the serial device will be sent successful pings.
through the GPRS connection.
Connection interval (default = 5 min): The time interval of the periodic connect function.
Ping remote host: Key in the IP address of the remote host.
6-4