0% found this document useful (0 votes)
274 views6 pages

Operational Software Loading Procedures

This document provides procedures for loading operational software onto the Circular Force Active Vibration Control System (CF-AVCS) of an AW139 helicopter. It involves connecting a laptop to the AVCS control panel and using maintenance software to upload new software files. Files must be loaded onto the central controller and each CFG (Circular Force Generator) in sequence. Version numbers are checked after each upload to confirm successful loading.

Uploaded by

ZeusIzquierdo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
274 views6 pages

Operational Software Loading Procedures

This document provides procedures for loading operational software onto the Circular Force Active Vibration Control System (CF-AVCS) of an AW139 helicopter. It involves connecting a laptop to the AVCS control panel and using maintenance software to upload new software files. Files must be loaded onto the central controller and each CFG (Circular Force Generator) in sequence. Version numbers are checked after each upload to confirm successful loading.

Uploaded by

ZeusIzquierdo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

AW139 IETP 36th Issue Unmaintained Copy Page 1 of 6

Circular Force Active Vibration Control System (CF-AVCS) - Operational


software loading procedures

Table of contents
References
Preliminary Requirements
Procedure
Requirements After Job Completion
List of tables
1 References
2 Access points
3 Zones
4 Required Conditions
5 Support Equipment
6 Supplies
7 Spares
List of figures
1 Circular force active vibration control system (CF-AVCS) - Operational software loading
procedures (Sheet 1 of 3)
1 Circular force active vibration control system (CF-AVCS) - Operational software loading
procedures (Sheet 2 of 3)
1 Circular force active vibration control system (CF-AVCS) - Operational software loading
procedures (Sheet 3 of 3)
2 AVCS control panel

References

Table 1 References
Data Module Title
39-A-00-00-00-00A-02AA-D Maintenance publication - List of effectivity codes
39-A-00-20-00-00A-120A-A Helicopter safety - Pre-operation (make helicopter safe for
maintenance)
39-A-12-41-00-00A-510A-A External electrical power - Disconnect procedure
39-A-12-41-00-00A-730A-A External electrical power - Connect procedure
39-B-18-33-00-00A-32EA-K Circular Force Active Vibration Control System (CF-AVCS) -
System identification check
39-B-18-33-00-00A-33AA-K Circular Force Active Vibration Control System (CF-AVCS) -
Connection/disconnection of laptop computer

Table 2 Access points

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020
AW139 IETP 36th Issue Unmaintained Copy Page 2 of 6

Access Panel / Door Id Data Module


No Access Point

Table 3 Zones
Zone ID Data Module
No Zones

Preliminary Requirements

Required Conditions
Table 4 Required Conditions
Data Module/Technical
Conditions
Publication
The helicopter must be safe for maintenance 39-A-00-20-00-00A-120A-A
The external electrical power must be connected to 39-A-12-41-00-00A-730A-A
the helicopter

Support Equipment
Table 5 Support Equipment
Nomenclature
No Support Equipment

Supplies
Table 6 Supplies
Nomenclature
No Supplies

Spares
Table 7 Spares
Identification
Nomenclature Qty
No.
18-33-00-04-
Central controller software installation disk AR
006
AR

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020
AW139 IETP 36th Issue Unmaintained Copy Page 3 of 6

Identification
Nomenclature Qty
No.
CFG command lane software installation 18-33-00-04-
disk 015
Controller configuration PDIF software 18-33-00-04-
AR
installation disk 007

Safety Conditions
No Safety Condition

Procedure

Note
To know the meaning of the effectivity code (or codes) shown in this data module, refer
to 39-A-00-00-00-00A-02AA-D.
1 Make sure that all circuit breakers on the AVCS OMNI BUS panel in the baggage
compartment are closed.

2 Make sure that the circuit breakers that follow on the auxiliary circuit-breaker panel are
closed:
- AVCS OMNI PWR (CB282)
- AVCS OMNI CTRL (CB484).

3 Connect the laptop computer to the AVCS control panel. Refer to data module 39-B-18-33-
00-00A-33AA-K.

4 Run the Maintenance Software.

5 The computer display must show the initial screen (Main Page) (Detail A of Figure 1 ).

6 Select the “Connection Settings” option (Detail B).

7 Make sure that the screen shows the “Connection Settings” window (Detail C).

8 Make sure that the “CAN Port” field show the USB port of the connected computer.

9 Put the Central controller software installation disk (18-33-00-04-006 ) in the computer.

10 Select “1M” in the “Baud Rate” filed (Detail C).

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020
AW139 IETP 36th Issue Unmaintained Copy Page 4 of 6

11 Select “SW-11076-1.a21” in the “A2L Path” field (Detail C).

12 Push the “SAVE” button (Detail C).

13 Push the “Connect” button on the “Link Status” window (Detail A).

14 Make sure that “Connected” is shown in the “Link Status” window in a green background
(Detail D).

15 Load the central controller software:


15.1 Select the “Upload” option on the Main Page, then select “Application” (Detail E).
15.2 In the “Upload File” window select (Detail F):
15.2.1 The SW-11076-1.hex file in the “Filename” field.
15.2.2 Select “CC” (Central Controller) in the “Devices to Program” field.
15.3 Push the “PROGRAM” button (Detail F).
15.4 After the software is fully loaded, push the “OK” button in the pop up window (Detail H).
15.5 Push the “System Version Check” button in the “User Action” window (Detail G).
15.6 Make sure that the central controller data that follows are shown on the screen:
- App Part No: SW-11076-1
- App CRC (Cyclic Redundancy Checksum): 0x204B0C73.

15.7 Remove the central-controller software-installation disk from the computer.

16 Load the CFG Command-lane software:


16.1 Put the CFG command lane software installation disk (18-33-00-04-015 ) in the computer.
16.2 Select the “Upload Option” on the Main Page, then select “Application” (Detail E).
16.3 In the “Filename” field of the “Upload File” select the SW-11079-1.hex file (Detail F).
16.4 Push the “PROGRAM” button (Detail F).
16.5 In the “Devices to program” field, select the Circular Force Generators (CFG) that are
installed in the helicopter (Detail F):
- CFG 0
- CFG 5.

16.6 Push the “PROGRAM” button.


16.7 After the software is fully loaded, the status is shown again in the Accelerometer RMS
Levels and Actuator Peak Levels (Detail A). Do the steps that follow:
16.7.1 Select the “Unload” option on the Main Page, then select “PDIF” (Detail E).
16.7.2 Select the SW-11078-1.hex file.
16.8 Do Step 16.4 thru Step 16.6 again.
16.9 Push the “System Version Check” button in the “User Action” window (Detail G).

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020
AW139 IETP 36th Issue Unmaintained Copy Page 5 of 6

16.10 Make sure that the data that follows are shown on the screen for each of the CFG installed:
- App Part No: SW-11079-1
- App CRC: 0xD23F85FA
- PDIF PN: SW-11078-1
- PDIF CRC: 0xDB7DEF6C.

16.11 Remove the CFG command-lane software installation disk from the computer.

17 Load the central controller PDIF (Parameter Data Item File) software:
17.1 Put the Controller configuration PDIF software installation disk (18-33-00-04-007 ) in the
computer.
17.2 Select the “Upload” option on the Main Page, then select PDIF (Detail E).
17.3 In the “Upload File” window select (Detail F):
17.3.1 The SW-11077-1.hex file in the “Filename” field.
17.3.2 Select “CC” (Central Controller) in the “Device to Program” field.
17.3.3 Push the “PROGRAM” button.
17.4 After the software is fully loaded, push the “System Version Check” button in the “User
Actions” window (Detail G).
17.5 Make sure that the central controller data that follows are shown on the screen:
- PDIF PN: SW-11077-1
- PDIF CRC: 0x8957D9D4
- PDIF VER: 01.01.0100.

17.6 Remove the CFG command-lane software-installation disk from the computer.

18 On the AVCS control panel (1, Figure 2 ) make sure that:


- The PWR ON light is on or the CFG PWR is on for the helicopters [11X]
- The STATUS indicator is blank.

19 Close the AVCS PANEL circuit breaker (CB283) on the auxiliary circuit-breaker panel.

20 On the AVCS control panel make sure that:


- The PWR ON light or the CFG PWR light (helicopters [11X]) goes off
- The STATUS indicator shows the FAIL legend.

21 Do the software load check:


21.1 On the “Main Page” of the computer display, push the “Disconnect” button on the “Link
Status” window (Detail D of Figure 1 ).
21.2 Make sure that “Disconnected” is shown in the “Link Status” window in a green background
(Detail A).
21.3 Set the ON/OFF switch on the AVCS control panel (1, Figure 2 ) to OFF.

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020
AW139 IETP 36th Issue Unmaintained Copy Page 6 of 6

21.4 Open the AVCS CTRL circuit breaker (CB484).


21.5 Set the ON/OFF switch on the AVCS control panel (1) to ON.
21.6 Close the AVCS CTRL circuit breakers (CB484).
21.7 Run the Maintenance Software.
21.8 Make sure that the computer display shows the initial screen (Main Page) (Detail A of Figure
1 ).
21.9 Push the “Connect” button on the “Link Status” window (Detail A).
21.10 Make sure that “Connected” is shown in the “Link Status” window in a green background
(Detail D).
21.11 Push the “System Version Check” button in the “User Action” window (Detail G).
21.12 Make sure that the central controller data shown on the screen is the same of the data
shown in Step 15.6 .
21.13 Push the “System Version Check” button.
21.14 Make sure that the central controller data shown on the screen is the same of the data
shown in Step 17.5 .
21.15 Push the “System Version Check” button.
21.16 Make sure that the data shown on the screen for each of the CFG installed is the same of
the data shown in Step 16.10 .
21.17 Do Step 21.1 and Step 21.2 again.

22 Disconnect the laptop computer from the AVCS control panel. Refer to data module 39-B-18
-33-00-00A-33AA-K.

Requirements After Job Completion

1 Remove all the tools and the other items from the work area. Make sure that the work area
is clean.

2 Disconnect the external electrical power from the helicopter. Refer to 39-A-12-41-00-00A-
510A-A

3 Do the system identification check. Refer to 39-B-18-33-00-00A-32EA-K

AMP - 39-B-18-33-00-00A-75CA-K Circular Force Active Vibration Control System (CF... Printed on 25/05/2020