Service Manual (6.0) PDF
Service Manual (6.0) PDF
Service Manual (6.0) PDF
0
HiPath 5000 V6.0
Service Manual
ESHB.60.030.06.03.22 03/06
*1PP31003-H3560-S100-3-7620*
1P P31003-H3560-S100-3-7620
Siemens AG 2006 ●
Siemens Communications,
Hofmannstraße 51, D-81359 München, Germany
Reference No.: P31003-H3560-S100-3-7620
Subject to availability. Right of modification reserved.
hp3hp5shTOC.fm
Contents
Contents 0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-1
hp3hp5shTOC.fm
Contents
2.6.4 Bandwidth Control for IP Networking Channels (PBX Networking Channels) . . . 2-29
2.6.5 DMC (Direct Media Connection) Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
2.6.6 ISDN Routing/PPP Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
2.6.7 Fax / Modem Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
2.6.8 Determining the Number of HG 1500 Boards Required . . . . . . . . . . . . . . . . . . . 2-31
2.6.8.1 Sample Calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
2.6.8.1.1 Calculation Example 1: 32 IP Networking Connections to HiPath 3750,
HiPath 3700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
2.6.8.1.2 Calculation Example 2: 96 IP workpoint clients and 16 IP networking
connections to HiPath 3750, HiPath 3700 . . . . . . . . . . . . . . . . . . . . . . . 2-35
2.6.8.1.3 Calculation Example 3: 200 IP Workpoint Clients and Internet
Access to HiPath 3750, HiPath 3700 . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-36
2.6.8.1.4 Calculation Example 4: IP Networking Connections and Voice over
PPP (ISDN Routing) to HiPath 3750, HiPath 3700. . . . . . . . . . . . . . . . . 2-38
2.6.8.1.5 Calculation Example 5: Virtual Private Network VPN . . . . . . . . . . . . . . . 2-39
2.6.8.1.6 Calculation Example 6: Connecting teleworkers via VPN . . . . . . . . . . . . 2-41
2.6.8.1.7 Calculation Example 7: Virtual Private Network VPN with Customer
Specifications: 1000 Kbps Bandwidth for Data Transfer, Remaining
Bandwidth for Voice Transmission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43
2.6.8.2 Notes on the Maintenance of Gateway Channels HiPath 3000/5000
V5.0 or later . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45
2.7 Technical Specifications for HiPath 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46
2.8 Interface-to-Interface Ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48
2.9 Numbering Plan for HiPath 3000/5000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49
2.10 Technical Specifications and Compliance to HiPath 3000 . . . . . . . . . . . . . . . . . . . . 2-50
2.10.1 CE Compliance (Not for U.S.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-50
2.10.2 Compliance with US and Canadian Standards (For U.S. and Canada Only) . . 2-50
2.10.2.1 FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
2.10.2.1.1 FCC Rules, Part 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
2.10.2.1.2 FCC Rules, Part 68 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51
2.10.2.2 Industry Canada Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54
2.10.2.2.1 REN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54
2.10.2.2.2 Equipment Attachment Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-54
2.10.3 SAFETY International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-55
2.11 Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56
2.11.1 Electrical Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56
2.11.2 Mechanical Operating Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56
3 Boards for HiPath 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 Central Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.2.1 CBCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
3.2.2 CBRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
3.2.3 CBCPR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32
3.2.4 CBSAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35
P31003-H3560-S100-3-7620, 03/06
0-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-3
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
0-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-5
hp3hp5shTOC.fm
Contents
4.2.7 Using an External Main Distribution Frame or External Patch Panel . . . . . . . . . . 4-66
4.2.7.1 Using an External Main Distribution Frame MDFU-E S30805-U5283-X . . . . 4-67
4.2.7.1.1 Mounting the Main Distribution Frame (MDFU-E) . . . . . . . . . . . . . . . . . . 4-68
4.2.7.1.2 Laying the Line Network and Jumpers on the MDFU-E . . . . . . . . . . . . . 4-68
4.2.7.2 Inserting the External Patch Panel S30807K6143-X . . . . . . . . . . . . . . . . . . 4-72
4.2.7.2.1 Installing the Patch Panel in a 19-Inch Cabinet. . . . . . . . . . . . . . . . . . . . 4-73
4.2.7.2.2 Connecting the Line Network to the External Patch Panel . . . . . . . . . . . 4-74
4.2.7.3 Inserting External S0 Patch Panel C39104-Z7001-B3 . . . . . . . . . . . . . . . . . 4-76
4.2.7.3.1 Installing the S0 Patch Panel in the 19-Inch Cabinet. . . . . . . . . . . . . . . . 4-77
4.2.7.3.2 Connecting Lines to the External S0 Patch Panel . . . . . . . . . . . . . . . . . . 4-78
4.2.7.4 For U.S. only: Connecting Network Facilities. . . . . . . . . . . . . . . . . . . . . . . . . 4-80
4.2.8 Loading the System Software and Installing Subboards on the CBSAP . . . . . . . 4-81
4.2.9 Connecting Workpoint Clients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-82
4.2.10 Making Trunk and Networking Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-82
4.2.11 Performing a Visual Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-83
4.3 Installing HiPath 3750, HiPath 3700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85
4.3.1 Installation Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85
4.3.2 Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-86
4.3.3 Installing HiPath 3750. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-88
4.3.3.1 Selecting the Installation Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-89
4.3.3.1.1 For U.S. only: AC outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-90
4.3.3.2 Unpacking the Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-91
4.3.3.3 Install MDFU or MDFU-E (not for USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-92
4.3.3.4 Setting up the System Cabinets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-93
4.3.3.4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-93
4.3.3.4.2 Removing the Cabinet Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-94
4.3.3.4.3 Setting Up a Single Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-95
4.3.3.4.4 Mounting a One-Cabinet System on the Wall (for U.S. only) . . . . . . . . . 4-95
4.3.3.4.5 Stacking Two Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-97
4.3.3.4.6 For U.S. only: Mounting Two Cabinets Stacked on the Wall . . . . . . . . 4-100
4.3.3.4.7 Setting Up a Two-Cabinet System Side by Side . . . . . . . . . . . . . . . . . . 4-103
4.3.3.4.8 Setting Up a Stacked Three-Cabinet System . . . . . . . . . . . . . . . . . . . . 4-104
4.3.3.4.9 For U.S. only: Installing the Seismic Anchors . . . . . . . . . . . . . . . . . . . 4-106
4.3.3.5 Grounding the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-108
4.3.3.5.1 Not for U.S.: Grounding the System . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-108
4.3.3.5.2 For U.S. only: Grounding the System . . . . . . . . . . . . . . . . . . . . . . . . . . 4-111
4.3.3.6 Checking the Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-113
4.3.3.7 Connecting the Cable to the Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-114
4.3.3.7.1 Backplanes on the “8-Slot” Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . 4-114
4.3.3.7.2 Connection between the MDFU or MDFU-E and Backplane . . . . . . . . 4-119
4.3.3.8 Laying the Line Network and Setting Jumpers on the MDFU or MDFU-E. . 4-124
4.3.3.8.1 For U.S. only: Connecting Network Facilities . . . . . . . . . . . . . . . . . . . . 4-128
4.3.4 Installing HiPath 3700 (19-Inch Cabinet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-129
4.3.4.1 Selecting the Installation Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-130
P31003-H3560-S100-3-7620, 03/06
0-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-7
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
0-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-9
hp3hp5shTOC.fm
Contents
8 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
8.3 Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-4
8.3.1 Products and Components subject to Mandatory Licensing . . . . . . . . . . . . . . . . . 8-4
8.3.2 Grace Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.3.3 License Failure Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
8.3.4 Performing Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
8.4 Licensing Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
8.4.1 HiPath 3000 as a Standalone System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
8.4.2 Networked HiPath 3000 Systems without HiPath 5000 RSM. . . . . . . . . . . . . . . . 8-14
8.4.3 Networked HiPath 3000 Systems with HiPath 5000 RSM . . . . . . . . . . . . . . . . . . 8-15
8.4.4 Upgrading to HiPath 3000 V6.0, HiPath 5000 V6.0 . . . . . . . . . . . . . . . . . . . . . . . 8-18
8.4.5 Combining Standalone Systems (HiPath 3000) to Form a Network with
HiPath 5000 RSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
8.4.6 Removing a Standalone System from a Network with HiPath 5000 RSM . . . . . . 8-23
8.4.7 Replacing License-sensitive Hardware (Changing the MAC Address) . . . . . . . . 8-24
8.5 Licensing optiClient Attendant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27
8.5.1 optiClient Attendant V7.0 Connected to HiPath 3000 V6.0 . . . . . . . . . . . . . . . . . 8-27
8.5.2 optiClient Attendant V7.0 Connected to HiPath 3000 < V5.0 . . . . . . . . . . . . . . . . 8-29
8.5.3 Upgrading optiClient Attendant V6.0 –> V7.0 when Upgrading to HiPath 3000
V5.0 or Later. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-31
8.5.4 Upgrade optiClient Attendant V6.0 –> V7.0 on HiPath 3000 < V5.0 . . . . . . . . . . 8-33
8.5.5 Changing Licenses on an optiClient Attendant V7.0 when Upgrading to
HiPath 3000 V5.0 or Later . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-35
8.6 Protection Against License Manipulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-37
9 Expanding and Upgrading HiPath 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.2 Expanding HiPath 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.2.1 Replacing Peripheral Boards for HiPath 3800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.2.2 Replacing Peripheral Boards for HiPath 3750 and HiPath 3700 . . . . . . . . . . . . . . 9-4
9.2.3 Connecting a printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6
9.2.4 ECR with HiPath 3700, HiPath 3500, HiPath 3300 (not for U.S. and Canada) . . . 9-8
9.2.4.1 ECR Control, Display, and Connecting Elements . . . . . . . . . . . . . . . . . . . . . . 9-9
9.2.4.2 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
9.2.4.3 Installation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
9.2.4.4 Expansion Cabinet Rack ECR With Batteries . . . . . . . . . . . . . . . . . . . . . . . . 9-13
9.2.4.4.1 Installing Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15
9.2.4.5 Expansion Cabinet Rack ECR With Batteries and EPSU2-R . . . . . . . . . . . . 9-18
9.2.4.5.1 Connecting a Fan (if needed) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-21
9.2.5 Connecting Special Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
9.2.5.1 Entrance Telephones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-24
9.2.5.1.1 Information on Third-Party Entrance Telephones . . . . . . . . . . . . . . . . . . 9-25
9.2.5.2 Connecting Speakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-27
P31003-H3560-S100-3-7620, 03/06
0-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-11
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
0-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-13
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
0-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 0-15
hp3hp5shTOC.fm
Contents
P31003-H3560-S100-3-7620, 03/06
0-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Overview
1 Important Information
1.1 Overview
Service Manual, HiPath 3000 V6.0, HiPath 5000 V6.0: P31003-H3560-S100-3-7620, 03/06
(ESHB.60.030.06.03.22)
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Structure of this Electronic Service Manual, page 1-2
Electrical Environment, page 1-4
Safety Information, page 1-5
● Safety Information: Dangers
● Safety Information: Warnings
● Safety information: Cautions
● General Information
● What To Do in an Emergency
● Reporting Accidents
● Safety Information for Australia (For Australia Only)
Privacy and Data Security, page 1-14
Information on the Intranet, page 1-15
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-1
inform.fm
Important Information
Structure of this Electronic Service Manual
Warning
7 Only authorized service personnel are permitted to work on the system.
The information provided in this document contains merely general descriptions or character-
istics of performance which in case of actual use do not always apply as described or which
may change as a result of further development of the products. An obligation to provide the rel-
evant characteristics shall only exist if expressly agreed in the terms of contract. The trade-
marks used are owned by Siemens AG or their respective owners.
P31003-H3560-S100-3-7620, 03/06
1-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Structure of this Electronic Service Manual
● Introductory information on the subject of IP can be found in Chapter 13, “IP Fundamen-
tals”.
● The following appendices contain lists with programming codes, IP protocols, port num-
bers: Appendix A, “System Programming Codes (Expert Mode Codes)”, Appendix B,
“Codes for Activating/Deactivating Features” and Appendix C, “IP Protocols and
Port Numbers Used with HiPath 3000/5000 V6.0”.
● Appendix D, “Identifying System Power Requirements” provides information about the
resource requirements of the boards and components of the HiPath 3000 systems.
● Appendix E, “Notes for editing the file snmpd.cnf” is aimed at users who have suffi-
cient knowledge of SNMP to modify trap destinations and community names on the HiPath
Fault Management Desktop.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-3
inform.fm
Important Information
Electrical Environment
This device has been manufactured in accordance with our certified envi-
ronmental management system (ISO 14001). This process ensures that en-
ergy consumption and the use of primary raw materials are kept to a mini-
mum, thus reducing waste production.
P31003-H3560-S100-3-7620, 03/06
1-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Safety Information
Safety symbols
This manual uses the following symbols to indicate potential hazards:
Danger
7 This symbol warns that a situation may cause death or serious injury.
Warning
7 This symbol indicates hazards which may lead to serious injury.
Caution
7 This symbol indicates a risk of damage to hardware or software.
1 5 3 0 6 4 2
Electricity Weight Heat Fire Chemicals ESD* Laser
* electrostatically sensitive devices
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-5
inform.fm
Important Information
Safety Information
Grounding
Never operate systems that require a ground wire connection without a ground wire connected.
Connect the system to the ground wire correctly before starting up and connecting the stations.
Dangerous voltages
Voltages above 30 Vac (alternating current) or 60 Vdc (direct current) are dangerous.
Damage
● Replace the power cable immediately if it shows any signs of damage.
● Replace any damaged safety equipment (covers, labels and protective cables) immediate-
ly.
Accessories
Use only original accessories or components approved for the system. Failure to observe these
instructions may damage the equipment or even violate safety and EMC regulations.
P31003-H3560-S100-3-7620, 03/06
1-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Safety Information
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-7
inform.fm
Important Information
Safety Information
General safety
● The surface of a mirror is conductive. Do not touch powered circuits with a mirror. To do so
can cause personal injury and machine damage.
● Disconnect all power before working near power supplies unless otherwise instructed by a
maintenance procedure.
● Do not attempt to lift objects that you think are too heavy for you.
● Never look directly at a laser beam.
P31003-H3560-S100-3-7620, 03/06
1-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Safety Information
Damage
Only use tools and equipment which are in perfect condition. Do not use equipment with visible
damage.
Laying cables
Lay cables so as to prevent any risk of them being damaged or causing accidents, such as trip-
ping.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-9
inform.fm
Important Information
Safety Information
Connecting lines
● All cables and lines leaving a system cabinet must be shielded between the connection
point in the cabinet and, at the very least, the point at which they leave the cabinet.
Use a clip and pressure screw to contact all braided shields to the cabinet outlet. This also
applies to continuously connected service equipment.
● Connect all cables to the specified connection points only.
Checking tools
Check your tools regularly. Only use intact tools.
Condensation
Condensation may form if equipment is brought onto the operating premises from a cold envi-
ronment. Wait until the temperature of the equipment has adjusted to the ambient temperature
and is completely dry before starting it up.
Wall mounting
Some walls (such as plasterboard walls) have a reduced load-bearing capacity. Before starting
wall mounting, check the load-bearing capacity of the walls.
P31003-H3560-S100-3-7620, 03/06
1-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Safety Information
Flammable materials
● Do not store combustible gases or flammable materials in cabinets near the equipment in-
stallation site.
● Do not store documents, descriptions, operating instructions, and similar flammable mate-
rials in the cabinet.
Workplace hazards
● Ensure that the workplace is well lit.
● A neat workplace helps reduce the risk of accidents.
●
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-11
inform.fm
Important Information
Safety Information
Actions in emergencies
● Remain calm in the event of an accident.
● Disconnect the power before touching the victim.
● If you do not know how to disconnect the power, use a nonconducting object, such as a
wooden broom handle, to push or pull the victim away from electrical contact.
First aid
● Be familiar with first aid for electrical shock. Familiarity with the various resuscitation meth-
ods required for breathing/heartbeat restoration and burn treatment are essential in emer-
gencies of this kind.
● Administer resuscitation immediately if the person is not breathing (mouth-to-mouth or
mouth-to-nose).
● If you are trained and certified, administer cardiac compression if the heart is not beating.
P31003-H3560-S100-3-7620, 03/06
1-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Safety Information
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-13
inform.fm
Important Information
Privacy and Data Security
P31003-H3560-S100-3-7620, 03/06
1-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inform.fm
Important Information
Information on the Intranet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 1-15
inform.fm
Important Information
Information on the Intranet
P31003-H3560-S100-3-7620, 03/06
1-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Overview
2 System Data
2.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
HiPath 3000, page 2-3
● Introduction, page 2-3 (electrical environment, systems)
● Design and Dimensions of the HiPath 3000 Systems, page 2-4:
– Design and Dimensions of HiPath 3800
– Design and Dimensions of HiPath 3750
– Design and Dimensions of HiPath 3550
– Design and Dimensions of HiPath 3350
– Design and Dimensions of HiPath 3700
– Design and Dimensions of HiPath 3500
– Design and Dimensions of HiPath 3300
● System Environment of the HiPath 3000 Systems, page 2-13:
– HiPath 3800 System Environment
– HiPath 3750 and HiPath 3700 System Environment
– HiPath 3550 System Environment
– HiPath 3350 System Environment
– HiPath 3500 System Environment
– HiPath 3300 System Environment
HiPath 5000, page 2-19
System-Specific Capacity Limits for HiPath 3000, HiPath 5000, page 2-22
Static Configuration Rules, page 2-24
Dynamic Configuration Rules, page 2-26
● Gateway Channels (DSP Channels), page 2-26
● MOH Channels (G.711, G.723, G.729), page 2-28
● IP Networking Channels (PBX Networking Channels), page 2-28
● Bandwidth Control for IP Networking Channels (PBX Networking Channels), page 2-29
● DMC (Direct Media Connection) Channels, page 2-29
● ISDN Routing/PPP Channels, page 2-29
● Fax / Modem Channels, page 2-30
● Determining the Number of HG 1500 Boards Required, page 2-31
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-1
sysdat.fm
System Data
Overview
Topic
Technical Specifications for HiPath 3000, page 2-46
Interface-to-Interface Ranges, page 2-48
Numbering Plan for HiPath 3000/5000, page 2-49
Technical Specifications and Compliance to HiPath 3000, page 2-50
● CE Compliance (Not for U.S.), page 2-50
● Compliance with US and Canadian Standards (For U.S. and Canada Only), page 2-50
● SAFETY International, page 2-55
Environmental Conditions, page 2-56
● Electrical Operating Conditions, page 2-56
● Mechanical Operating Conditions, page 2-56
P31003-H3560-S100-3-7620, 03/06
2-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
2.2.1 Introduction
Electrical environment
HiPath 3000 is intended for use in dwellings, businesses, and industry. When the system is op-
erated in an industrial environment, additional measures may be necessary for ensuring immu-
nity from electromagnetic radiation (refer to Section 2.11).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-3
sysdat.fm
System Data
HiPath 3000
Two configurations
Depending on the requirements, HiPath 3800 can be used as:
● a single-cabinet system (basic cabinet BC)
● a two-cabinet system (BC + expansion cabinet EC)
Design
The basic cabinet BC has nine slots and the expansion cabinet EC has thirteen slots for pe-
ripheral boards. The common control board CBSAP has a fixed slot (slot 6, only in the BC).
Depending on your requirements, up to three LUNA2 power supply units can be used in the
basic cabinet BC and up to four in the expansion cabinet EC.
Peripheral devices can be connected to the HiPath 3800 in a number of different ways:
● SIVAPAC connectors are available on the backplane for connecting the external main dis-
tribution frame MDFU-E using CABLUs (prefabricated cabling units) or to connect external
patch panels.
● Connector panels with RJ45 jacks for connecting the peripheral device directly. The con-
nector panels are clipped onto the SIVAPAC connectors on the backplane.
● For U.S. only: connector panels with CHAMP jack for connecting the peripheral device di-
rectly. The connector panels are clipped onto the SIVAPAC connectors on the backplane.
● Connector panels with SIPAC 1 SU connectors for connecting the external main distribu-
tion frame MDFU-E or external patch panels using CABLUs. The connector panels are
clipped onto the SIVAPAC connectors on the backplane.
The type of connection used will be decided in consultation with the customer on conclusion of
the agreement. The cabinets will be delivered accordingly with or without clipped-on connector
panels.
P31003-H3560-S100-3-7620, 03/06
2-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
Dimensions
approx. 440 mm
EC
approx. 980 mm
BC approx. 430 mm
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-5
sysdat.fm
System Data
HiPath 3000
Three configurations
Depending on the requirements, HiPath 3750 can be used as:
● a single-cabinet system (BC)
● a two-cabinet system (BC + EC1)
● A three-cabinet system (BC + EC1 + EC2)
Design
The HiPath 3750 uses “8-slot” cabinets, where expansion cabinet 1 (EC1) and expansion cab-
inet 2 (EC2) are identical in design.
The BC has seven slots available for peripheral boards and each expansion cabinet has eight
slots. The UPSM power supply (in all cabinets) and the CPCPR central control board (only in
the BC) have fixed positions.
Up to two cabinets can be stacked.
A main distribution frame unit is needed to complete the communication system.
P31003-H3560-S100-3-7620, 03/06
2-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
Dimensions
EC1
approx. 980 mm
MDFU
MDFU-E
approx.
MDFU
EC2 BC
Cable duct
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-7
sysdat.fm
System Data
HiPath 3000
Design
The housing intended for wall mounting (Figure 2-3) HiPath 3550 contains one shelf with six
slot levels. The slot levels (shown in Figure 4-104), numbered in ascending order from the at-
tachment side, have the following assignments:
● Slot levels 1-3: peripheral boards (two slots per level).
● Slot level 4: CBCC control board only
● Slot level 5: SIPAC slot (for HiPath 3750 boards).
● Slot level 6: Optional boards (up to 5 modules)
The power supply is on the rear panel of the subrack.
The connection cables to the peripherals (telephones, trunk connections etc.) can be connect-
ed directly. Use an external MDFU in certain situations (CMI).
Dimensions
450 mm
200 mm
P31003-H3560-S100-3-7620, 03/06
2-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
Design
The housing intended for wall mounting (Figure 2-4)HiPath 3350 contains one shelf with
three slot levels. The slot levels (shown in Figure 4-107), numbered in ascending order
from the attachment side, have the following assignments:
● Slot level 1: peripheral boards (two slots)
● Slot level 2: CBCC control board only
● Slot level 3: Optional boards (up to 5 modules)
The power supply is on the rear panel of the subrack.
The HiPath 3350 does not need an external main distribution frame. The connection cables
to the peripherals (telephones, trunk connections etc.) are directly connected to the
boards.
Dimensions
450 mm
128 mm
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-9
sysdat.fm
System Data
HiPath 3000
Three configurations
Depending on the requirements, HiPath 3700 can be used as:
● a single-cabinet system (BC)
● a two-cabinet system (BC + EC1)
● a three-cabinet system (BC + EC1 + EC2), only when the 19-inch cabinets are next to one
another and are accessible from the back.
A special mounting set enables installation in 19-inch cabinets.
Design
The HiPath 3700 uses “8-slot” cabinets. The BC has seven slots and the expansion cabinet has
eight slots available for peripheral boards. The UPSM power supply (in all cabinets) and the
CPCPR central control board (only in the BC) have fixed positions.
Dimensions
approx. 410 mm
EC1
approx. 980 mm
P31003-H3560-S100-3-7620, 03/06
2-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
Design
The housing intended for use with 19-inch cabinets (Figure 2-6) HiPath 3500 contains four slot
levels with the following assignments (represented in Figure 4-112):
● Slot levels 1-3: slide-in shelves for peripheral boards (2 boards can be plugged in on each
level)
● Slot level 4: slide-in shelf for CBRC control board
● Slot level 5: Optional boards (up to 3 modules)
The power supply is on the rear panel of the subrack.
The connection to peripherals (telephones, trunks, and others) is set up using MW8 jacks on
the boards front cover.
Dimensions
440 mm
155 mm
380 mm
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-11
sysdat.fm
System Data
HiPath 3000
Design
The housing intended for use with 19-inch cabinets (Figure 2-7)HiPath 3300 contains three
slots with the following assignments (represented in Figure 4-113):
● Slot level 1: slide-in shelves for two peripheral boards
● Slot level 2: slide-in shelf for CBRC control board
● Slot level 3: Optional boards (up to 3 modules)
The power supply is on the rear panel of the subrack.
The connection to peripherals (telephones, trunks, and others) is set up using MW8 jacks on
the board’s front cover.
Dimensions
440 mm
88 mm
380 mm
P31003-H3560-S100-3-7620, 03/06
2-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
HiPath 3800
Subscriber Line Modules Central Boards Trunk Boards
Options
ROW U.S. ROW U.S. ROW U.S.
IVMN8 CBSAP DIU2U
IVMNL CMS DIUN2
SLCN DBSAP PBXXX1
SLMA IMODN STMD3
SLMA21 LIMS STMI2
SLMA8 LUNA2 TM2LP
SLMO2 MMC TMC161
SLMO8 MPPI TMCAS-21 TMDID
STMD3 PDMX2 TMEW2
STMI2 PFT1/PFT4
REALS
RGMOD1
1 for selected countries only
2 used on the STMI2 board
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-13
sysdat.fm
System Data
HiPath 3000
P31003-H3560-S100-3-7620, 03/06
2-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
HiPath 3550
Subscriber Line Modules Central Boards Trunk Boards
Options
ROW U.S. ROW U.S. ROW U.S.
HXGS3 CBCC HXGS3
IVMS8 CMA STLS2
SLA8N CMS STLS4
SLA16N CUC STLSX2
SLA24N IMODN STLSX4
SLC16N LIM TCAS-22 TMGL4
SLMO24 MMC TLA2 TMQ4
SLU8 UPSC-D TLA4 TST1
STLS2 TLA8
STLS4 ALUM4 TMAMF1
STLSX2 ANI42 TMCAS2
STLSX4 EVM TS2
4SLA EXM
8SLA GEE12 EXMNA
16SLA GEE16
GEE50
UAM
MPPI
OPAL
PDM1
3
STBG4
STRB
V24/1
1 for Brazil, India, Malaysia, Singapore and ATEA countries only
2 for selected countries only
3 For France only
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-15
sysdat.fm
System Data
HiPath 3000
HiPath 3350
Subscriber Line Modules Central Boards Trunk Boards
Options
ROW U.S. ROW U.S. ROW U.S.
HXGS3 CBCC HXGS3
IVMP8 CMA STLS2
IVMS8 CMS STLS4
SLU8 CUP STLSX2
STLS2 IMODN STLSX4
STLS4 LIM TLA2 TMGL4
STLSX2 MMC TLA4 TMQ4
STLSX4 PSUP TLA8
4SLA UPSC-D
8SLA
16SLA ALUM4
ANI41
EVM
EXM
GEE12 EXMNA
GEE16
GEE50
UAM
MPPI
OPAL
PDM1
STBG42
STRB
V24/1
1 for selected countries only
2 For France only
P31003-H3560-S100-3-7620, 03/06
2-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 3000
HiPath 3500
Subscriber Line Modules Central Boards Trunk Boards
Options
ROW U.S. ROW U.S. ROW U.S.
HXGR3 CBRC HXGR3
IVMS8R CMA STLS4R
SLU8R CMS STLSX4R
STLS4R CUCR TCASR-21 TMGL4R
STLSX4R IMODN TS2R TST1
8SLAR LIM TLA4R
MMC
UPSC-DR
ANI4R1
EVM
EXMR
MPPI
OPALR
PDM1
STRBR
UAMR
1 for selected countries only
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-17
sysdat.fm
System Data
HiPath 3000
HiPath 3300
Subscriber Line Modules Central Boards Trunk Boards
Options
ROW U.S. ROW U.S. ROW U.S.
HXGR3 CBRC HXGR3
IVMP8R CMA STLS4R
IVMS8R CMS STLSX4R
SLU8R CUPR TLA4R TMGL4R
STLS4R IMODN
STLSX4R LIM
8SLAR MMC
UPSC-DR
ANI4R1
EVM
EXMR
MPPI
OPALR
PDM1
STRBR
UAMR
1 for selected countries only
P31003-H3560-S100-3-7620, 03/06
2-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 5000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-19
sysdat.fm
System Data
HiPath 5000
● Customer License Agent CLA (service for analyzing and decrypting a HiPath License Man-
agement license file)
● Central License Manager CLM (CLA front-end for reading in licenses in online and offline
mode)
● Personal Call Manager PCM (Web-based application for the configuration and administra-
tion of personal call forwarding operations)
● HiPath FM Desktop V3.0 (Java-based application for error signaling)
● GetAccount (application that prepares generated call data records for further processing.)
P31003-H3560-S100-3-7620, 03/06
2-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
HiPath 5000
HiPath Cordless
Office
IP Network
optiClient 130 optiClient
V5.0 Attendant
HiPath 3750
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-21
sysdat.fm
System Data
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
IP stations (system clients, H.323 500 250/5003 1928 1928 968 9 968 10 1000
clients)
Total number of TDM stations2 384 250/3843 9611 7711 12 5713 4114 –
15 2 16 17 18
Analog stations 384 250/384 96 44 36 20 –
TDM Stations
P31003-H3560-S100-3-7620, 03/06
2-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
System-Specific Capacity Limits for HiPath 3000, HiPath 5000
1 Testing is not required on stations and lines up to the maximum configuration. Testing using the project planning tool is
mandatory for configurations which include UCD/ACD, more than one SLCN, or groups of more than 10 stations (intranet:
http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index_en.htm).
2 Only configurations that do not exceed this limit will be supported.
3 Depending on the system configuration and performance, the specified capacity limits may not always be achieved. To
ensure that the dynamic capacity limit of HiPath 3750 or HiPath 3700 is not exceeded, the configuration can be tested
using the project planning tool (intranet: http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index_en.htm). Testing
is not required for configurations of up to 250 stations and 90 lines. Testing using the project planning tool is mandatory
for configurations which include UCD/ACD, more than one SLC16N, or groups of more than 10 stations.
4 Up to 96 of the 192 stations can be TDM stations.
5 Up to 61 of the 192 stations can be TDM stations (4xa/b + 1xUP0/E + 7xBS/32xHiPath Cordless Office stations at the cen-
tral board + 3xSLU8R or 3x8SLAR).
6 Up to 41 of the 96 stations can be TDM stations (4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central
board + 1x16SLA).
7 Up to 33 of the 96 stations can be TDM stations (4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central
board + 1xSLU8R or 1x8SLAR).
8 These are administrative capacity limits.
9 Due to the power consumption of HG 1500, a UPSC-D must be used.
10 Due to the power consumption of HG 1500, a UPSC-DR must be used.
11 If the total number of UP0/E stations, analog stations and additional stations connected using an adapter is greater than
72, an external EPSU2 power supply unit must be used.
12 4xa/b + 1xUP0/E + 7xBS/32xHiPath Cordless Office stations at the central board + 5xSLU8R or 5x8SLAR.
13 4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 2x16SLA.
14 4xa/b + 5xUP0/E + 3xBS/16xHiPath Cordless Office stations at the central board + 2xSLU8R or 2x8SLAR.
15 Testing using the project planning tool is not required for configurations of up to 384 analog stations, no other station types,
and 90 lines. Configurations that contain UCD/ACD or more than one SLC16N or groups with more than ten stations
should always be checked using the project planning tool (intranet: http://intranet.mch4.siemens.de/syseng/perfeng/tools/
hpt/index_en.htm).
16 4xa/b at the central board + 5x8SLAR.
17 4xa/b at the central board + 2x16SLA.
18 4xa/b at the central board + 2x8SLAR.
19 8xUP0/E at the central board + 5xSLU8 + 1xSLMO24.
20 8xUP0/E at the central board + 5xSLU8R.
21 8xUP0/E at the central board + 2xSLU8.
22 8xUP0/E at the central board + 2xSLU8R.
23 The total number of UP0/E stations and additional stations connected using an adapter is limited to 384.
24 If the total number of UP0/E stations and additional stations connected using an adapter is greater than 24, a UPSC-D/
UPSC-DR must be used.
25 Due to the 5-V power supply unit, one SLC16N and a maximum of two HG 1500 V3.0 boards can be used.
26 64 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board.
27 Two HG 1500 boards can be installed if PDM1 is not being used.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-23
sysdat.fm
System Data
Static Configuration Rules
For information on the configuration of HG 1500 boards, refer to the HG 1500 Ad-
> ministration Manual.
In HiPath 3000/5000 V6.0, HG 1500 provides the resources named in Table 2-8 via the
HG 1500 boards defined as media gateways (= gateway HG 1500, see Page 10-38).
Table 2-9 shows the board-specific capacity limits (maximum configuration) for the correspond-
ing functions.
Table 2-8 Technical Data (Resources) of the HG 1500 Boards Defined as Media Gate-
ways
P31003-H3560-S100-3-7620, 03/06
2-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Static Configuration Rules
Table 2-8 Technical Data (Resources) of the HG 1500 Boards Defined as Media Gate-
ways
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-25
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
2-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-27
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
2-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-29
sysdat.fm
System Data
Dynamic Configuration Rules
If a large number of IP workpoint clients is required, the HG 1500 board may not also be used
as an ISDN router. In this case, ISDN routing functionality must be assigned to an individual
HG 1500 board.
P31003-H3560-S100-3-7620, 03/06
2-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-31
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
2-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-33
sysdat.fm
System Data
Dynamic Configuration Rules
Performance requirement
32 gateway channels via LAN interface 1 should be included in the calculation. The setting “En-
hanced B Channels” must be activated for this via the WBM. The Virtual Private Network VPN
and Firewall functions are automatically deactivated when this setting is activated.
The signaling load has to be taken into account when calculating performance.
P31003-H3560-S100-3-7620, 03/06
2-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
Performance requirement
Thirty-one gateway channels via LAN interface 1 should be included in the calculation. The set-
ting “Enhanced B Channels” must be activated for this via the WBM. The Virtual Private Net-
work VPN and Firewall functions are automatically deactivated when this setting is activated.
The signaling load has to be taken into account when calculating performance.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-35
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
2-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
Upstream: Downstream:
24000 bps 256000 bps
= 17 packets/sec = 183 packets/sec
1400 bytes/packet 1400 bytes/packet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-37
sysdat.fm
System Data
Dynamic Configuration Rules
Performance requirement
The payload and the signaling load have to be taken into account when calculating perfor-
mance.
P31003-H3560-S100-3-7620, 03/06
2-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-39
sysdat.fm
System Data
Dynamic Configuration Rules
P31003-H3560-S100-3-7620, 03/06
2-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
Performance requirement
Calculation of the dynamic performance requirement for the SDSL connection based on the re-
quired data exchange rate (512 kbps = (512 X 1000)/8 bps = 64000 bps per route). The follow-
ing formula applies for 500 byte packet length:
64000 bps
= 128 packets/route = 256 packets/s for both routes
500 bytes/packet
Since VPN functionality is required, the WBM setting “Enhanced B Channels” is deactivated.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-41
sysdat.fm
System Data
Dynamic Configuration Rules
Bandwidth requirement
For information on bandwidths, refer to the System Description HiPath 3000/5000 V6.0
P31003-H3560-S100-3-7620, 03/06
2-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
125000 bps
= 250 packets/route = 500 packets/s for both routes
500 bytes/packet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-43
sysdat.fm
System Data
Dynamic Configuration Rules
Bandwidth requirement
For information on bandwidths, refer to the System Description HiPath 3000/5000 V6.0
P31003-H3560-S100-3-7620, 03/06
2-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Dynamic Configuration Rules
In V5.0 and later, when a number of trunks is configured for IP networking with Hi-
> Path 3000 Manager E (IP networking channels), this no longer results in the reser-
vation of B channels. This means that the available B channels can be used as gate-
way channels.
These resources are administered centrally via a single HG 1500 board, i.e. the ’Sig-
naling Gateway’ (= Gatekeeper HG 1500), regardless of how many HG 1500 boards
are available in a system.
Sample Connection Scenarios:
● Internal node connections between IP workpoint clients are direct payload connections. No
gateway channel is necessary. The number of possible concurrent connections depends
on the number of licensed IP workpoint clients.
● Node-to-node connections (IP networking) between IP workpoint clients are direct payload
connections. No gateway channel is necessary. The number of possible concurrent con-
nections depends on the number of IP networking channels available.
● Node-to-node connections (IP networking) between TDM workpoint clients require one IP
networking channel per connection and one gateway channel per node.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-45
sysdat.fm
System Data
Technical Specifications for HiPath 3000
P31003-H3560-S100-3-7620, 03/06
2-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Technical Specifications for HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-47
sysdat.fm
System Data
Interface-to-Interface Ranges
Table 2-15 Telephone Interface-to-Interface Ranges (with J-Y (ST) 2x2x0.6, 0.6 mm
diameter)
P31003-H3560-S100-3-7620, 03/06
2-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Numbering Plan for HiPath 3000/5000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-49
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
Guideline Standard
R&TTE Directive 99/5/EEC ● EN 60950-1: 2001 (Safety)
● EN61000-6-2 (EMC Immunity Industrial)
● EN55024 (EMC Immunity Residential)
● ETS 300 329 (DECT Emission/Immunity)
● TBR 06, ETS 301489-1/6 (DECT Air Interface)
Table 2-18 Compliance with US and Canadian Standards (For U.S. and Canada Only)
P31003-H3560-S100-3-7620, 03/06
2-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-51
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
will notify you in advance. If this is not possible, you will receive notification at the earliest pos-
sible opportunity. In this context you will also be informed that you can lodge a complaint with
the FCC.
REN
The Ringer Equivalence Number (REN) is used to determine the number of devices that can
be connected to a telephone line so that all the devices ring when that telephone number is
called. In most areas, but not all, the sum of the RENs of all devices connected to a line should
not exceed five. Contact the local telecommunication company to determine the maximum REN
for your calling area.
P31003-H3560-S100-3-7620, 03/06
2-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-53
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
Each Siemens system discussed in this section is capable of providing user access to interstate
providers of operator services through the use of equal access codes. Modifications by aggre-
gators to alter these capabilities are a violation of the Telephone Operator Consumer Services
Improvement Act of 1990 and Part 68 of the FCC Rules.
2.10.2.2.1 REN
The Ringer Equivalence Number (REN) defines how many devices can be connected to a tele-
phone line at the same time. The termination of an interface may consist of any combination of
devices subject only to the requirement that the sum of the RENs of all the devices does not
exceed five.
P31003-H3560-S100-3-7620, 03/06
2-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
sysdat.fm
System Data
Technical Specifications and Compliance to HiPath 3000
DANGER
7 Users should not attempt to make such connections themselves, but should contact
the electric inspection authority, or electrician, as appropriate.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 2-55
sysdat.fm
System Data
Environmental Conditions
Caution
7 Avoid exposing the system to direct sunlight and heaters (excessive heat may dam-
age the system).
Systems covered with condensation must be dried before being used. Do not start
up the system until it has thoroughly dried.
P31003-H3560-S100-3-7620, 03/06
2-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
Caution
7 The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
3.1 Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-1
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-3
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-5
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-7
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-9
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-11
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-13
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-15
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Overview
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-17
boards.fm
Caution
7 The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
3.2.1 CBCC
Introduction
The CBCC board (Central Board with Coldfire Com, S30810-Q2935-A301) performs all central
control and switching functions for HiPath 3550 and HiPath 3350 (see Figure 3-1).
The CBCC central control board needs to be replaced for HiPath 3000 V6.0. The
> CBCC S30810-Q2935-A301 board is required.
The “old” CBCC board S30810-Q2935-A201 is not supported.
Subboards
The following subboards can be used depending on the application:
● Clock module CMA or CMS (optional)
● MMC multimedia card
● IMODN integrated modem card new (optional)
● LIM LAN interface module (optional)
● MPPI music on hold (optional)
● EVM entry voice mail (optional)
Outputs, interfaces
● Eight digital UP0/E subscriber lines
For example, UP0/E workpoint clients or BS3/1 base stations for HiPath Cordless Office can
be connected here.
● Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
For Australia only: The T/R interfaces supply a ring voltage of 35 Veff. Depending on the
terminals connected, we cannot exclude the possibility of errors occurring during ringing
state.
P31003-H3560-S100-3-7620, 03/06
3-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Please note that only one MPPI module may be connected. In other words, you
> can connect either MPPI S30122-K5380-X200 via X4 or MPPI S30122-K7275-
B via X19/X20.
● Options bus (O bus)
● Two V.24 interfaces. The second interface is implemented via the V24/1 option.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-19
boards.fm
Figure
X5 2 X11 2 X6 2
V24/1
X8 O bus
CMA X7
X14 X20 X15 X16
2
MPPI IMODN
CMS
2
X13 X17
X19
X27
X12
X32
EVM LIM
MMC
X30/31 X18
X1 X2 X4 X3
1 1 2 1
Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for
> testing (module test at the factory). Disconnection does not necessarily delete the
customer database (CDB). To delete the CDB, use the reset switch.
P31003-H3560-S100-3-7620, 03/06
3-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
X1 to X4 contact assignments
S0 interface assignment
Contact S0
X30 X31
1 – –
2 – –
3 S0 port 1, transmit + S0 port 2, transmit +
4 S0 port 1, receive + S0 port 2, receive +
5 S0 port 1, receive – S0 port 2, receive –
6 S0 port 1, transmit – S0 port 2, transmit –
7 – –
8 – –
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-21
boards.fm
Table 3-7 CBCC - LAN Connector Assignment (RJ45 Jack) via LIM
P31003-H3560-S100-3-7620, 03/06
3-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Table 3-8 Default Numbering Plan When Using CBCC in HiPath 3550
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-23
boards.fm
Table 3-9 Default Numbering Plan When Using CBCC in HiPath 3350
P31003-H3560-S100-3-7620, 03/06
3-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.2 CBRC
Introduction
The CBRC board (Central Board Rack Com, S30810-Q2935-Z301) performs all central control
and switching functions for HiPath 3500 and HiPath 3300 (see Figure 3-2).
The CBRC central control board needs to be replaced for HiPath 3000 V6.0. The
> CBRC board (S30810-Q2935-Z301) is required.
The “old” CBRC board S30810-K2935-Z is not supported.
Subboards
The following subboards can be used depending on the application:
● Clock module CMA or CMS (optional)
● MMC multimedia card
● IMODN integrated modem card new (optional)
● LIM LAN interface module (optional)
● MPPI music on hold (optional)
● EVM entry voice mail (optional)
Outputs, interfaces
● Eight digital UP0/E subscriber lines
For example, UP0/E workpoint clients or BS3/1 base stations for HiPath Cordless Office can
be connected here.
● Four analog T/R subscriber lines
For U.S. only: These interfaces do not support the connection of external extensions via
OPS (Off-Premises Station) signaling.
For Australia only: The T/R interfaces supply a ring voltage of 35 Veff. Depending on the
terminals connected, we cannot exclude the possibility of errors occurring during ringing
state.
● Two digital S0 interfaces (CO (default) or station)
● Backplane (CUCR or CUPR) connection via slots 1 (X11), 2 (X5) and 3 (X6)
● Music on hold: MPPI, EXMR
● Options bus (O bus)
● V.24 interface
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-25
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Figure
X5 2 X11 2 X6
X20
X8 O bus
CMA
MPPI/
X14 X15 X16 EXMR
IMODN
CMS X19
2
X13 X17
X27
X12
X32
EVM LIM
1 X3
MMC X18
1 X1 X9
Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for
> testing (module test at the factory). Disconnection does not necessarily delete the
customer database (CDB). To delete the CDB, use the reset switch.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-27
boards.fm
S0 interface assignment
P31003-H3560-S100-3-7620, 03/06
3-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Table 3-14 CBRC - LAN Connector Assignment (RJ45 Jack) via LIM
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-29
boards.fm
Table 3-15 Default Numbering Plan When Using CBRC in HiPath 3500
P31003-H3560-S100-3-7620, 03/06
3-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Table 3-16 Default Numbering Plan When Using CBRC in HiPath 3300
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-31
boards.fm
3.2.3 CBCPR
Introduction
The CBCPR board (shown in Figure 3-3) performs all central control and switching functions
for HiPath 3750 and HiPath 3700.
Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for
> testing (module test at the factory). Disconnection does not necessarily delete the
customer database (CDB). To delete the CDB, use the reset switch.
Subboards
The following subboards can be used depending on the application:
● CMS clock module (optional)
● MMC multimedia card
● IMODN integrated modem card new (optional)
● LIM LAN interface module (optional)
Section 3.2.12 contains information on how to make the LAN connection.
● MPPI music on hold (optional)
V.24 interfaces
● To connect a service PC, you can access the first V.24 interface (9-pin SUB-D plug) on the
CBCPR from the front of the basic cabinet (after removing the cover). (See Figure 3-3.)
● You can access the second V.24 interface (25-pin SUB-D plug) via the backplane of the
basic cabinet (X7).
P31003-H3560-S100-3-7620, 03/06
3-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
CMA
1
X13
CMS
1
Reset/reload
X14
switch
RUN LED
X27
Batt.
MMC
LAN connector,
1 IMODN 1
8-pin RJ45 LIM
jack
X12 X15
V.24 interface,
9-pin SUB-D
plug (service PC or X18
1 1
application)
MPPI X17
1
X16
X19 X20
1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-33
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.4 CBSAP
Introduction
The CBSAP board (Central Board Synergy Access Platform) performs all central control and
switching functions for HiPath 3800 (see Figure 3-4).
Capacity
● DTMF transmitters: 12
● DTMF receivers: 12
● Tone generators: 16
● Dial tone receivers: 4
Subboards
The following subboards can be used depending on the application:
● CMS clock module (optional)
● MMC multimedia card
● IMODN integrated modem card new (optional)
● LIMS LAN interface module (optional)
Contains two Ethernet (10BaseT) LAN connectors (8-pin RJ45 jacks):
– LAN1 (administration via HiPath 3000 Manager E and CTI functions)
– LAN2 (not assigned)
● MPPI music on hold (optional)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-35
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
MMC IMODN
LIMS
CMS
MPPI
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-37
boards.fm
Front panel
Two Ethernet (10BaseT) LAN connectors (8-pin RJ45 jacks) via LIMS:
● LAN2 (not assigned)
● LAN1 (administration via HiPath 3000 Manager E and CTI func-
tions)
The LAN interface status is indicated by two LEDs:
● LED1:
– Green = 100 Mbps online (link)
– Yellow = 10 Mbps online (link)
– Flashing = active
● LED2 (green):
– On = full-duplex (FDX)
– Off = half-duplex
P31003-H3560-S100-3-7620, 03/06
3-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-39
boards.fm
3.2.5 CMA
Caution
7 Place the central control board on a flat surface before inserting the CMA subboard.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
Spacing bolts
Introduction
The Clock Module ADPCM CMA (S30807-Q6931-X) is an optional subboard for the CBCC and
CBRC central control boards. The CMA module is needed for special HiPath Cordless Office
configurations.
All clock module small (CMS) functions are available when you insert a CMA module.
Please refer to Page 3-41 for recommendations on CMA module implementation.
P31003-H3560-S100-3-7620, 03/06
3-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.6 CMS
Caution
7 Place the central control board on a flat surface before inserting the CMS subboard.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
Introduction
The Clock Module Small CMS (S30807-Q6928-X) is an optional subboard for the HiPath 3000
central control boards and guarantees greater clock accuracy.
● Ethernet/IP
HiPath 3000 (10/100 HiPath 3000
BaseT)
System 1 System(s)
1+n
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-41
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-43
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.7 CR8N
Introduction
The CR8N (Code Receiver) board is an optional plug-in module and can be used in any slot in
all HiPath 3750 and HiPath 3700 cabinets.
The CR8N board is required when:
● A high outgoing traffic load and a large number of analog subscribers exist.
● A Hicom Phonemail system with more than six ports and the automatic attendant function
is connected.
● An external automatic attendant is being used as a virtual attendant and the system has a
large number of analog trunks.
In these cases, the six code receivers (for tone dialing on analog telephones) that are already
present in the system on the CBCPR are not sufficient. Adding a CR8N board provides another
eight code receivers and eight code transmitters. Up to two CR8Ns can be installed in each sys-
tem. A CR8N board and a CR8 board (S30810-Q2513-X) cannot be used in the same system
simultaneously.
You can also install or remove a CR8N board during operation. If you remove it while the system
is in the operating state, you risk interrupting DTMF signal processing. It is always recommend-
ed that you remove or install the board only while the system is switched off.
Note the following recommendations for using the CR8N board if a Hicom Phonemail system,
voice mail system, or automatic attendant is connected:
● Up to 8 ports: No CR8N board required.
● 9 to 24 ports: One CR8N board required.
● Over 24 ports: Two CR8N boards required.
These are general recommendations only. In some cases, a CR8N board may already be re-
quired for six ports under extreme load conditions.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-45
boards.fm
H1 (red)
LEDs
H2 (green)
P31003-H3560-S100-3-7620, 03/06
3-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
CBCC
Slot 2 (8 x UP0/E) Slot 1 (2 x S0) Slot 3 (4 x T/R)
Peripheral board
Slot 6 (X40) Slot 7 (X50)
CUC
Peripheral board
Slot 8 (X60) Slot 9 (X70)
Peripheral board
Slot 4 (X20) PSU/UPS (X1) Slot 5 (X30)
CBRC
Slot 2 (8 x UP0/E) Slot 1 (2 x S0) Slot 3 (4 x T/R)
Peripheral board
Slot 6 (X40) Slot 7 (X50)
CUCR
Peripheral board
Slot 8 (X60) Slot 9 (X70)
Peripheral board
Slot 4 (X20) PSU/UPS (X1) Slot 5 (X30)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-47
boards.fm
CUP
CUPR
P31003-H3560-S100-3-7620, 03/06
3-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.10 DBSAP
A prerequisite for expanding HiPath 3800 to a two-cabinet system is that the DBSAP (Driver
Board for Synergy Access Platform) board is mounted on the backplane of the expansion cab-
inet.
DBSAP ensures that the expansion cabinet receives HDLC, PCM and clock signals from the
basic cabinet. In addition, an ID signal is created which indicates the availability of an expan-
sion cabinet to the CBSAP.
Front Back
With 68-pin DB68 mini-jack for connect- With four jacks for plugging into the
ing the connection cable to the basic cab- backplane of the expansion cabinet
inet
The cable (C39195-Z7611-A10) is used as the connection cable between basic cab-
> inet (X201 jack) and expansion cabinet (DBSAP board). To ensure smooth opera-
tion, use only shielded cables with a maximum length of 1 m.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-49
boards.fm
DBSAP
P31003-H3560-S100-3-7620, 03/06
3-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.11 IMODN
Caution
7 Place the central control board on a flat surface before inserting the IMODN sub-
board.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
Introduction
The Integrated Modem Card New (IMODN - S30807-Q6932-X100) is an optional subboard for
HiPath 3000 central control boards.
It permits the use of remote service (analog mode up to 33.6 Kbps) over analog trunks without
an external modem.
IMODN is the compatible successor of IMODC. Functional differences between both modules
only exist in the higher transmission speed of the IMODN.
Loadable loadware
To avoid exchanging the IMODN subboard during a software upgrade, IMODN loadware is au-
tomatically updated in V4.0 SMR-08 and later.
Updating the IMODN loadware takes approx. 10 minutes beginning with the idle system status.
The red LED on the IMODN lights up repeatedly during the loading procedure. IMODN is ready
as soon as the green LED starts to flash.
If the IMODN loadware is not updated when the system is reset, the green LED starts to flash
approx. 10 seconds after the reset. The green LED continues to flash after the system boot.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-51
boards.fm
3.2.12 LIM
Caution
7 The LAN interface module must not be plugged in or out when the system is ener-
gized.
Place the central control board on a flat surface before inserting the LIM subboard.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
Introduction
The LAN Interface Module (LIM - S30807-Q6930-X) is an optional plug-in card for all HiPath
3000 central control boards apart from CBSAP (HiPath 3800).
The board provides an Ethernet (10BaseT/10 Mbps) LAN connection via an 8-pin RJ45 jack.
The LIM module can be used for administration via HiPath 3000 Manager E and for CTI func-
tions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call At-
tempts = number of connection attempts during busy traffic hours) is restricted to 400 at a max-
imum of six TAPI ports. The use of “power dialers” is not approved.
In V6.0 or later, the system software deactivates an existing LIM module when an HG 1500
board is inserted. You cannot operate the LIM module and a HG 1500 board simultaneously in
a HiPath 3000.
P31003-H3560-S100-3-7620, 03/06
3-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
CBCPR
X18
to LAN
Adapter cable
(C39195-Z7213-A1) approx. 300 mm
Stripped length
(see Figure 3-16) approx. 60 mm
Figure 3-15 LIM in HiPath 3750 and HiPath 3700 - Procedure for LAN Connection
Figure 3-16 LIM in HiPath 3750 and HiPath 3700 - Adapter Cable (C39195-Z7213-A1)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-53
boards.fm
Figure 3-17 LIM in HiPath 3750 and HiPath 3700 - Attachment of the Patch Cable to the
Backplane Grill
P31003-H3560-S100-3-7620, 03/06
3-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.13 LIMS
Caution
7 The LIMS module must not be plugged in or out when the system is energized.
Introduction
The LAN Interface Module for SAPP LIMS (S30807-Q6721-X) is an optional plug-in card for
the CBSAP central control board in HiPath 3800.
The board provides two Ethernet (10BaseT) LAN connectors via two 8-pin RJ45 jacks:
● LAN1 (administration via HiPath 3000 Manager E and CTI functions)
● LAN2 (not assigned)
The LIMS module can be used for administration via HiPath 3000 Manager E and for CTI func-
tions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call At-
tempts = number of connection attempts during busy traffic hours) is restricted to 400 at a max-
imum of six TAPI ports. The use of “power dialers” is not approved.
In V6.0 or later, the system software deactivates an existing LIMS module when an STMI2
board is inserted. You cannot operate the LIMS module and an STMI2 board simultaneously in
a HiPath 3800.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-55
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.14 LUNA2
Introduction
LUNA2 (Line-powered Unit for Network-based Architecture No. 2) is used as the central power
supply in HiPath 3800. Depending on the system configuration up to three LUNA2 modules can
be used in the basic cabinet and up to four LUNA2 modules can be used in the expansion cab-
inet.
When expanding the HiPath 3800 to a two-cabinet system, two LUNA2 modules in the basic
cabinet and three LUNA2 modules in the expansion cabinet are enough to supply the maximum
configuration in Table 2-7. For information on how to calculate the number of LUNA2 modules
required, see Page 3-63.
You can use a third LUNA2 in the basic cabinet and a fourth in the expansion cabinet to ensure
error-free operation if one LUNA2 module fails (redundant LUNA2) or to load a connected bat-
tery pack or a battery cabinet. These operating modes cannot be combined.
LUNA2 supports power supply and battery management functions. No other components are
required if it is operated as a power supply. To maintain short-term battery emergency operation
after a power failure, that is, to use uninterruptible power supply functions, you must also con-
nect a battery pack per system cabinet or a BSG 48/38 battery cabinet (including battery charg-
er).
LUNA2 is used in all countries.
Licensed batteries
S30122-K5950-Y200: Battery pack 4 x 12 V/7 Ah
This is the only battery pack approved for operation with LUNA2.
Part numbers
● LUNA2: S30122-K7686-L1, S30122-K7686-M1
For production-related reasons, two different LUNA2 modules with the same functions are
used. Technically identical, the two models have minor mechanical differences and are fully
compatible with each other.
● Battery pack 4 x 12 V/7 Ah: S30122-K5950-Y200
(the connection cable for LUNA2 is part of the battery pack)
● Battery cabinet BSG 48/38: S30122-K5950-F300 (Page 3-64)
– Battery cable for BSG 48/38: S39195-A7985-B10
(A battery cable is required for each system cabinet to be connected.)
– Battery 12 V/38 Ah: S30122-X5950-F320
(Four batteries necessary for each BSG 48/38.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-57
boards.fm
Technical specifications
● Nominal voltage range: 110 VAC - 240 VAC
● Nominal frequency: 50 Hz - 60 Hz
● Output voltage (battery charging voltage, if a LUNA2 is used as a battery charger): –
54.7 VDC; –53.5 VDC (for gell cell batteries, currently not released)
● Output current (battery charge current, if a LUNA2 is used as a battery charger): up to 2 A
● Bridging times
Table 3-25 lists the maximum possible bridging times (emergency battery operation in case
of power failure) with battery pack S30122-K5950-Y200 ((48 V/7 Ah) and battery housing
BSG 48/38 (S30122-K5950-F300).
Table 3-25 LUNA2 - Bridging Times with Battery Pack 48 V/7 Ah and Upright Battery
Housing BSG 48/38
P31003-H3560-S100-3-7620, 03/06
3-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Removal tab
You can use a screwdriver here to remove the
LUNA2 from the shelf.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-59
boards.fm
Caution
7 The switches for deactivating the secondary operating voltage (system supply
voltage) must be set to “DC-OFF” on all LUNA2s during maintenance work that
requires the system to be de-energized (for example, central board replace-
ment). The system is only in de-energized state if the switches on ALL
LUNA2s are set to “DC-OFF” position.
The system is only restarted if all LUNA2 switches are returned to the “DC-ON”
position.
● Switches for setting the operating mode (the operating mode must be set before the outer
panel is mounted):
– Mode 1: For use as power supply (LED illuminated)
– Mode 2a: For use as battery charger (LED flashing) with a charging voltage of
54.7 Vdc
– Mode 2b: For use as battery charger (LED flashing) with a charging voltage of
53.5 Vdc
From a technical viewpoint, there are no differences between the LUNA2 slots.
> A LUNA2 can be used in all slots, regardless of the selected operating mode.
To achieve a uniform LUNA2 configuration worldwide, the following rules should
be observed:
● The power supplies that are used to supply the system directly should be
plugged in at LUNA2 slots 1, 2, and 3 (expansion cabinet only).
● At the LUNA2 slot marked “4”, only power supplies that
– are used for LUNA2 redundancy should be plugged in (set to mode 1).
– are used as a battery charger should be plugged in (set to mode 2a or
mode 2b).
P31003-H3560-S100-3-7620, 03/06
3-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Slots
Push the LUNA2 power supply unit into the slots provided in the lower part of the system cab-
inet shelf until you hear a click (see Figure 4-19).
The power supply unit slots must be covered with the outer panel shown in Figure 3-20 (basic
cabinet) and in Figure 3-21 (expansion cabinet) before the system is started up.
Figure 3-20 LUNA2 Slots in the Basic Cabinet (With Outer Panel Mounted)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-61
boards.fm
Figure 3-21 LUNA2 Slots in the Expansion Cabinet (With Outer Panel Mounted)
P31003-H3560-S100-3-7620, 03/06
3-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-63
boards.fm
BSG 48/38
You can use a BSG 48/38 battery cabinet instead of the battery pack to extend the bridging time
in the event of a power failure. The BSG 48/38 battery cabinet (S30122-K5950-F300) consists
of
● an upright housing
● a charging rectifier
● a battery set (38 Ah/48 V)
The battery cabinet is designed for direct connection to the HiPath 3800 communication sys-
tem. The DC power cable (S39195-A7985-B10) provided lets you connect any system cabinet
to the battery cabinet (do not connect to extension cables). Figure 3-23 is a schematic display
of the connections between the battery cabinet BSG 48/38 and HiPath 3800.
For detailed information about safety precautions as well as using and connecting
> the battery cabinet, refer to the installation and startup instructions that came with
the cabinet.
DC output 2:
–48-V special +– +–
outputs
BSG 48/38
DC output 1: 1
–48 V to HiPath
3800 2
AC input
230 V 3
Figure 3-22 Rear View of the BSG 48/38 Battery Cabinet (S30122-K5950-F300)
P31003-H3560-S100-3-7620, 03/06
3-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
HiPath 3800
Basic cabi-
net
DC connection cable
BSG 48/38 50 - 60 Hz
AC
with batt.set
(38 Ah/48 V)
Expan-
sion cabi-
AC input 1 net
DC
Output 1, 2 DC connection cable
–48 V
3
100 - 240 Vac DC
50 - 60 Hz
AC
DC port
(X209)
AC power
(X211, X212 (basic cabinet only))
Note: For reasons of clarity, the system cabinets are shown sepa-
rately and without grounding.
Figure 3-23 Connections Between the BSG 48/38 Battery Cabinet and HiPath 3800
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-65
boards.fm
3.2.15 MMC
Introduction
The Multi Media Card (MMC) is a plug-in memory card for the central control boards and con-
tains the CDB backup and the relevant version-specific application processor software (APS).
Please note that the MMC may only be replaced by a multimedia card approved by Siemens
AG. Cards that have not been approved may have a different internal structure which can affect
temporal access and certain features (for example, CDB backup and APS transfer).
HiPath 3000 V5.0 (or later) only supports 64 MB multimedia cards (MMC64).
> MMC16 (16 MB) cards cannot be used.
The MMC is checked during system startup. If the system detects an MMC16, the
startup is aborted.
HiPath 3700
HiPath 3500
HiPath 3300
HiPath 3300
with CBCC
with CBRC
in
countries
P31003-H3560-S100-3-7620, 03/06
3-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
HiPath 3800
HiPath 3750
HiPath 3550
HiPath 3350
HiPath 3350
HiPath 3700
HiPath 3500
HiPath 3300
HiPath 3300
with CBCC
with CBRC
in
countries
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-67
boards.fm
3.2.16 PSUP
Introduction
The power supply PSUP S30122-K5658-M (Figure 3-24) is used in HiPath 3350 (wall housing).
The device plugs into a special slot and is secured by screws. It connects to the power outlet
using a modular power cord.
A monitoring LED indicates the presence of the 5-V output voltage.
Technical specifications
● Nominal voltage range: 100 VAC - 240 VAC
● Nominal frequency: 50 Hz - 60 Hz
● Ring voltage generator: 75 VAC, 20/25/50 Hz
● Partial voltages: +5 Vdc, –48 V
● Power consumption: 70 W
Caution
7 System voltage can only be switched on or off by plugging in or out the power
plug.
50 Hz
20 Hz Slide switch for setting ring frequency
25 Hz for following country settings:
1
● 50 Hz = France
To CUP X1 ● 20 Hz = U.S.
● 25 Hz = Germany + international
50
Power plug
P31003-H3560-S100-3-7620, 03/06
3-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Introduction
The external ring voltage generator RGMOD (S30124-X5109-X) is required for generating ring
voltages for the HiPath 3800 SLMA2 board. RGMOD is plugged in on the backplane of the ba-
sic and/or expansion cabinet.
Danger
7 RGMOD must not be plugged in or out when the system is energized!
In normal mode, the ring voltage generator operates with voltages ranging from
+75 V to –170 V. The prescribed measures for protection against high voltage must
be taken when working on or close to the board.
When the ring voltage generator is removed, no ring tone is generated for the analog
telephones connected to the SLMA2.
A system cabinet can be fitted with a mix of SLMA, SLMA8 and SLMA2 boards. RG-
> MOD has no effect on SLMA and SLMA8, as these boards generate their own ring
voltage (35 Veff).
Table 3-28 RGMOD (for selected countries only) - Setting the Ring Voltages and Ring Fre-
quencies
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-69
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Installing RGMOD
The RGMOD ring voltage generator is plugged in at the rear of the backplane.
● Basic cabinet
When using one or more SLMA2 boards in the basic cabinet, RGMOD must be plugged
into the 10-pin port X214 of the basic cabinet (see Figure 3-25).
X214
Figure 3-25 HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabi-
net
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-71
boards.fm
● Expansion cabinet
When using one or more SLMA2 boards in the expansion cabinet, RGMOD must be
plugged into the 10-pin port X214 of the expansion cabinet (see Figure 3-26).
X214
Figure 3-26 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion
Cabinet
P31003-H3560-S100-3-7620, 03/06
3-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
3.2.18 UPSC-D
Introduction
The UPSC-D S30122-K5660-M300 board (Figure 3-27) is used in HiPath 3550 and HiPath
3350 (wall housing).
This module supports power supply and battery management functions. No other components
are required if it is operated as an AC power supply. To maintain short-term battery emergency
operation after a power failure, that is, to use uninterruptible power supply functions, you must
also connect a battery pack.
Warning
7 The UPSC-D power supply unit is only released for permanent AC power supply.
Permanent operation at a direct-current system is not allowed.
A DC power supply unit is only connected to bridge an AC power failure (emergency
battery operation).
If a 48-V direct-current system is being used instead of a battery pack for DC power
supply, connection must be performed as for a battery pack. The 48-V direct-current
system must not exceed the limit of 60 V in operating mode, during loading, and
when an error occurs. The direct-current system must not be connected to the
UPSC-D if this cannot be guaranteed.
If the power supplied by the UPSC-D is insufficient, an external EPSU2 power supply can be
installed to provide additional power. For this, the EPSU2’s DC connection needs to be con-
nected to the special -48 VDC input on the UPSC-D. The UPSC-D’s internal -48-V output is de-
activated when the external power supply is connected.
Danger
7 Do not use 24-V batteries (S30122-K5403-X) in conjunction with UPSC-D as an ex-
plosive gas (hydrogen + oxygen) escapes when the battery is overloaded.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-73
boards.fm
Technical specifications
● Nominal voltage range: 100 VAC - 240 VAC
● Nominal frequency: 50 Hz - 60 Hz
● Ring voltage generator: 75 VAC, 20/25/50 Hz
● Partial voltages: +5 Vdc, –48 V
● Battery charger: 4 x 12 V (40.8 V-55.2 V)
● Power consumption: 180 W
● Bridging times
Table 3-29 lists the maximum possible bridging times (emergency battery operation in case
of power failure) with battery pack S30122-K5928-X (48 V/1.2 Ah), depending on the sys-
tem.
Table 3-29 UPSC-D - Bridging Times with Battery Pack S30122-K5928-X (48 V/
1.2 Ah)
P31003-H3560-S100-3-7620, 03/06
3-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Diagram of UPSC-D
LED, yellow
green
Slide switch for activating/deactivating
1 the battery voltage (battery pack):
To ● up = off, battery voltage deactivated
LED, yellow (battery backup off)
CUC/ X1
CUP ● down = on, battery voltage activated
50 (battery backup on)
Ba
EP
Po
tte
we
SU
ry
rp
2
pa
lug
ck
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-75
boards.fm
Caution
7 System voltage can only be switched on or off by plugging in or out the power plug.
If using an uninterruptible power supply, switch off the battery voltage first.
● LED, green: +5-V output voltage is available.
● LED, yellow: –48-V output voltage is supplied by the external EPSU2 power supply.
● Slide switch for setting the ring frequency:
– 25 Hz (Germany + international market)
– 20 Hz (U.S.)
– 50 Hz (France)
● Slide switch for activating and deactivating the battery voltage (battery pack):
– up = off, battery voltage deactivated (battery backup off)
– down = on, battery voltage activated (battery backup on)
P31003-H3560-S100-3-7620, 03/06
3-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Connectors
Power plug
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-77
boards.fm
3.2.19 UPSC-DR
Introduction
The UPSC-DR S30122-K7373-M900 board (Figure 3-31) is used in HiPath 3500 and HiPath
3300 (19-inch housing).
This module supports power supply and battery management functions. No other components
are required if it is operated as an AC power supply. To maintain short-term battery emergency
operation after a power failure, that is, to use uninterruptible power supply functions, you must
also connect a battery pack (see Section 9.2.4).
Warning
7 The UPSC-DR power supply unit is only released for permanent AC power supply.
Permanent operation at a direct-current system is not allowed.
A DC power supply unit is only connected to bridge an AC power failure (emergency
battery operation).
If a 48-V direct-current system is being used instead of a battery pack for DC power
supply, connection must be performed as for a battery pack. The 48-V direct-current
system must not exceed the limit of 60 V in operating mode, during loading, and
when an error occurs. The direct-current system must not be connected to the
UPSC-DR if this cannot be guaranteed!
Danger
7 The UPSC-DR board is not insulated.
Consequently, a system using a UPSC-DR may only be operated with a closed
housing.
Before opening the housing, make sure that the system is de-energized as follows:
● by disconnecting the battery voltage and line voltage at any connected ECR
(see Section 9.2.4.1, “ECR Control, Display, and Connecting Elements”).
● by disconnecting the line cord attached to any connected batteries (installed in
the ECR) (see Section 9.2.4.4, “Expansion Cabinet Rack ECR With Batteries”).
● by disconnecting the line cord attached to any connected EPSU2-R (installed in
the ECR) (see Section 9.2.4.5, “Expansion Cabinet Rack ECR With Batteries
and EPSU2-R”).
● by disconnecting the power plug.
If the power supplied by the UPSC-DR is insufficient, an external EPSU2-R power supply can
be installed to provide additional power. To do this, connect the DC port on the EPSU2-R to the
special –48-Vdc input on the UPSC-DR. The UPSC-DR’s internal -48 V output is deactivated
when the external power supply is connected.
P31003-H3560-S100-3-7620, 03/06
3-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Licensed batteries
4 x V39113-W5123-E891 (4 x 12 V/7 Ah batteries)
These are the only batteries released for connection to UPSC-DR and installation in ECRs.
Danger
7 Do not use 24-V batteries (S30122-K5403-X) in conjunction with UPSC-DR as an
explosive gas (hydrogen + oxygen) escapes when the battery is overloaded.
Technical specifications
● Nominal voltage range: 100 VAC - 240 VAC
● Nominal frequency: 50 Hz - 60 Hz
● Ring voltage generator: 75 VAC, 20/25/50 Hz
● Partial voltages: +5 Vdc, –48 V
● Battery charger: 4 x 12 V (40.8 V-55.2 V)
● Power consumption: 180 W
● Bridging times
Table 3-30 lists the maximum possible bridging times (emergency battery operation in case
of power failure) with four batteries V39113-W5123-E891 (4 x 12 V/7 Ah batteries), de-
pending on the system.
Table 3-30 UPSC-DR - Bridging Times with four Batteries V39113-W5123-E891 (4 x
12 V/7 Ah Batteries)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-79
boards.fm
Diagram of UPSC-DR
LED, green
LED, yellow
P31003-H3560-S100-3-7620, 03/06
3-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
25 Hz
20 Hz
50 Hz
green
Slide switch for activating and deactivat-
1 ing the battery voltage (batteries):
To ● up = off, battery voltage deactivated
LED, yellow (battery backup off)
CUCR/CUPR X1
● down = on, battery voltage activated
50 (battery backup on)
Caution
The screw marked “ ” performs the
ground connection between UPSC-DR
and the 19-inch housing and must al-
ways be installed.
AC outlet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-81
boards.fm
Caution
7 System voltage can only be switched on or off by plugging in or out the power plug.
If using an uninterruptible power supply, switch off the battery voltage first.
● LED, green: +5-V output voltage is available.
● LED, yellow: –48-V output voltage is supplied by the external EPSU2-R power supply.
● Slide switch for setting the ring frequency:
– 25 Hz (Germany + international market)
– 20 Hz (U.S.)
– 50 Hz (France)
● Slide switch for activating and deactivating the battery voltage (batteries):
– up = off, battery voltage deactivated (battery backup off)
– down = on, battery voltage activated (battery backup on)
P31003-H3560-S100-3-7620, 03/06
3-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Connectors
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-83
boards.fm
3.2.20 UPSM
Introduction
Each cabinet in HiPath 3750 and HiPath 3700 requires one UPSM (Uninterruptible Power Sup-
ply Modular). This board supports power supply and battery management functions. No other
components are required if operated as an AC power supply. To maintain short-term battery
emergency operation after a power failure, that is, to use uninterruptible power supply func-
tions, you must also connect a battery pack per system cabinet or a BSG 48/38 battery cabinet
(including battery charger) to the UPSM.
Warning
7 The UPSM power supply is only released for permanent AC power supply. Perma-
nent operation at a direct-current system is not allowed.
A DC power supply unit is only connected to bridge an AC power failure (emergency
battery operation).
If a 48-V direct-current system is being used instead of a battery pack for DC power
supply, connection must be performed as for a battery pack. The 48-V direct-current
system must not exceed the limit of 60 V in operating mode, during loading, and
when an error occurs. The direct-current system must not be connected to the
UPSM if this cannot be guaranteed!
Each connection must have a ferrite bead provided between the UPSM and battery
> pack, battery cabinet or 48-V direct-current system. Insert the ferrite bead (Würth
742 7113 or C39022-Z7000-C7) with two windings into the connection cable at the
UPSM output.
You do not need a ferrite assembly when using the BSG 48/38 battery cabinet in ver-
sion 2 or later as the ferrite beads were integrated in the battery cabinet.
UPSM/PSUI mixed mode is only permitted in a system if the UPSM is operated without addi-
tional 48 V DC connection, that is in 110/220 V AC mode only.
Due to battery connection differences, mixed mode is not permitted in systems with uninterrupt-
ible power supply USVI. UPSM must not be implemented in these systems.
The UPSM is used in all countries. The ring frequency of the modular ring voltage generator
can be parameterized to suit country-specific requirements. For production-related reasons
there are two different UPSM models. Technically identical, the two models have minor me-
chanical differences and are fully compatible with each other.
The only exception is the UPSM model S30122-K5950-S121 which supplies a ring voltage of
60 Veff and is only implemented in the Republic of South Africa (RSA).
P31003-H3560-S100-3-7620, 03/06
3-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
Caution
7 When mounting the UPSM on the cabinet frame, be careful to prevent screws from
falling into the power supply unit through the ring generator opening.
If a screw falls inside the UPSM, remove the screw before starting up the unit.
Caution
7 The switches for deactivating the secondary operating voltage (system supply volt-
age) must be set to “Off” on all UPSMs during maintenance work that requires the
system to be de-energized (for example, central board replacement).
Part numbers
● UPSM: S30122-K5950-S100 (Figure 3-35), S30122-K5950-A100 (Figure 3-36), S30122-
K5959-S121 (for RSA only)
● Battery pack 4 x 12 V/7 Ah: S30122-K5950-Y200
(The connection cable for the UPSM is part of the battery pack.)
● Battery cabinet BSG 48/38: S30122-K5950-F300 (Page 3-89)
– Battery cable for BSG 48/38: S30122-X5950-F310
(One battery cable is required for each system cabinet (UPSM) to be connected.)
– Battery 12 V/38 Ah: S30122-X5950-F320
(Four batteries necessary for each BSG 48/38.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-85
boards.fm
Technical Specifications
● Nominal voltage range: 100 VAC - 240 VAC
● Nominal frequency: 50 Hz - 60 Hz
● Max. input current consumption: 5.4 A - 2.7 A
● Max. power consumption: around 430 W
● Output voltage (battery charging voltage): 42.5 - 55.2 VDC
● Output current (battery charge current): 0.8 A
(sufficient for battery set rating) = 7 Ah)
● Bridging times
Table 3-31 lists the maximum possible bridging times (emergency battery operation in case
of power failure) with battery pack S30122-K5950-Y200 (48 V/7 Ah).
Table 3-31 UPSM - Bridging Times with Battery Pack S30122-K5950-Y200 (48 V/
7 Ah)
P31003-H3560-S100-3-7620, 03/06
3-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
AC outlet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-87
boards.fm
FRONT REAR
VIEW VIEW
AC outlet
P31003-H3560-S100-3-7620, 03/06
3-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Central Boards
BSG 48/38
You can use a BSG 48/38 battery cabinet instead of a battery pack to extend the bridging time
in the event of a power failure. The BSG 48/38 battery cabinet (S30122-K5950-F300) consists
of
● an upright housing
● a charging rectifier
● a battery set (38 Ah/48 V)
The battery cabinet is designed for direct connection to the HiPath 3750 and HiPath 3700 com-
munication system. The DC power cable (S30122-X5950-F310) provided lets you connect any
UPSM to the battery cabinet (do not connect to extension cables). A schematic diagram shows
the connections between the BSG 48/38 battery cabinet and the communication system (UP-
SM) Figure 3-38.
For detailed information about safety precautions as well as using and connecting
> the battery cabinet, refer to the installation and startup instructions that came with
the cabinet.
DC output 2:
–48-V special +– +–
outputs
BSG 48/38
DC output 1: 1
–48 V to HiPath
3750 and HiPath 2
AC input 3700
230 V 3
Figure 3-37 Rear View of the BSG 48/38 Battery Cabinet (S30122-K5950-F300)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-89
boards.fm
BC
UPSM
DC connection cable
USVI (battery box)
UPSM
net 1
AC input 1 DC connection cable
DC
2 USVI (battery box)
Output 1,
–48 V
3 100 - 240 Vac
AC power
50 - 60 Hz
to UPSM
Figure 3-38 Connections between the BSG 48/38 Battery Cabinet and UPSM (HiPath
3750, HiPath 3700)
P31003-H3560-S100-3-7620, 03/06
3-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Caution
7 The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
Note
The HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 peripheral boards must be firmly
inserted into their slots; otherwise contact problems can cause board failure.
3.3.1 CSAPE
Introduction
In V6.0 or later, the cPCI box CSAPE (Central Shelf Access Point Emergency) can be installed
in the HiPath 3800 basic cabinet. The cPCI box contains two fan drawers, the AC power supply
unit ACPCI (part number S30124-X5166-X), and two slide-in shelves for the Embedded Appli-
cation Server EAS.
CSAPE is required when using HiPath All-in-One applications. Information about the supported
applications can be found in the HiPath All-in-One product documentation.
Installation of the cPCI box CSAPE in the system is a purely mechanical operation. There is no
electrical connection between the system and the cPCI box CSAPE All communication be-
tween HiPath 3800 and HiPath All-in-One takes place over the IP network.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-91
boards.fm
Front panel
Fan drawer
Fan drawer
P31003-H3560-S100-3-7620, 03/06
3-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Slot
Figure 3-40 shows the slot for the cPCI box CSAPE in the basic cabinet. Please refer to Special
board attachments for installation information.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-93
boards.fm
Introduction
The DIU2U (Digital Interface Unit 2 Universal) trunk module connects two digital trunks to Hi-
Path 3800 and in this way provides two primary rate interfaces (PRI) ISDN via T1 interfaces.
Connection types
● Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
AMOM must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
● Copper cable
The copper cable is connected to T1-CSU (Customer Service Unit) or DSU (Data Service
Unit) via the adapter cable (C39195-A7269-B625) shown in Figure 3-41.
Table 3-32 DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625)
P31003-H3560-S100-3-7620, 03/06
3-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-32 DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625)
Front panel
Interface 1
Interface 2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-95
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.3 DIUN2
Introduction
The DIUN2 (Digital Interface Unit ISDN) provides 2 x 30 B channels (voice channels) for HiPath
3800. These are used
● for the S2M trunk connection (via NT).
● for S2M networking via S2M lines.
In HiPath 3000/5000 V5.0 and later, the B channels in the DIUN2 board are subject
> to license. Information on licensing can be found in Chapter 8.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-97
boards.fm
Front panel
Interface 1
Interface 2
P31003-H3560-S100-3-7620, 03/06
3-98 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Connection types
● Fiber optic cable
The fiber optic cable is only connected via the front panel. The opto-electronic converter
AMOM must be used to connect a fiber optic cable to the 15-pin Sub-D jacks on the front
panel.
● Copper cable
The copper cable is only connected via the 15-pin Sub-D jacks on the front panel.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-99
boards.fm
Jack assignment
P31003-H3560-S100-3-7620, 03/06
3-100 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.4 HXGM3
Introduction
HXGM3 is a VoIP gateway board (VoIP - Voice over IP) which provides the functionality of
HG 1500 in HiPath 3750 and HiPath 3700:
● Connection of a local LAN to the HiPath 3000 and connection with external LANs via the
ISDN and DSL interfaces of HiPath 3000.
● Support for the conventional functions of an ISDN and DSL router with the additional func-
tionality of a media gateway for the transfer of voice, fax and data.
● Forwarding of calls between IP-supported networks (LAN, intranet, Internet) and circuit-
switched networks (ISDN, PSTN).
Configuration is performed via Web-based management (WBM) which enables the administra-
tion of HG 1500 without any special software requirements.
A combination of up to eight HXGM3 boards can be used per system, but the follow-
> ing restrictions must be observed:
● A maximum of four HXGM3 boards may be inserted per HiPath 3750 or HiPath
3700 cabinet.
● When using an HXGM3 in HiPath 3750 or HiPath 3700, a PSUI power supply
unit (if available) may have to be replaced with UPSM.
● To allow for future channel expansion with extension modules, the slot between
two HXGM3 boards should remain free.
● It is not possible to operate an HXGM3 and an LIM module simultaneously in a
HiPath 3750 or HiPath 3700.
For information on configuration, refer to the HG 1500 Administration Manual.
For information on how to calculate the number of boards required for HG 1500, see
Section 2.6.8.
Board versions
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-101
boards.fm
Extension modules
The HXGM3 board has three HGA (HiPath Gateway Accelerator) slots, which can be used to
connect the extension modules.
Table 3-38 HXGM3 Extension Modules
P31003-H3560-S100-3-7620, 03/06
3-102 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Interfaces/connectors
The HXGM3 board provides the following connectors:
● X10: 9-pin Sub-D plug for V.24 interface
● Backplane: The LAN adapter connector C39228-A7195-A10 (see Figure 3-46) is inserted
directly on the backplane connector SU Xx8 or SU Xx9 for a LAN connection. The LAN ca-
ble is connected via the RJ45 socket of the adapter.
For U.S. only: The LAN connection is made using a special adapter cable (CHAMP in ac-
cordance with RJ45) (see Figure 3-47).
Both LAN interfaces allow access to the Ethernet standard (IEEE 802.3) with 10 Mbps or
100 Mbps with automatic configuration. Manual configuration is also possible.
HGA slot 2
Backplane
LED H0 (red)
LED H1 (green)
LAN connections
HGA slot 0 HGA slot 1 via LAN adapter
connector:
V.24 interface X10 LAN 2 (SU Xx8)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-103
boards.fm
LED Meaning
Off Board is active but there are no active calls.
H1 - green
On At least one call is active.
On Error
H0 - red
Flashing Start (after a restart)
V.24 interface
The V.24 cable (C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
P31003-H3560-S100-3-7620, 03/06
3-104 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
SIPAC 1 SU
RJ45 jack jack (Back-
(to the LAN) plane Xx8
or Xx9)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-105
boards.fm
Figure 3-47 HXGM3 LAN Adapter Cable for Backplane (for U.S. only)
Table 3-42 HXGM3 - LAN Adapter Cable Assignment (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
3-106 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
HXGS3 and HXGR3 are VoIP gateway boards (VoIP - Voice over IP), which provide the func-
tionality of HG 1500 in HiPath 3550, HiPath 3350 (HXGS3) and HiPath 3500, HiPath 3300
(HXGR3):
● Connection of a local LAN to the HiPath 3000 and connection with external LANs via the
ISDN and DSL interfaces of HiPath 3000.
● Support for the conventional functions of an ISDN and DSL router with the additional func-
tionality of a media gateway for the transfer of voice, fax and data.
● Forwarding of calls between IP-supported networks (LAN, intranet, Internet) and circuit-
switched networks (ISDN, PSTN).
Configuration is performed via Web-based management (WBM) which enables the administra-
tion of HG 1500 without any special software requirements.
Up to three boards can be used in HiPath 3550 and HiPath 3500. To support this
> maximum configuration, slot 10 (board in HiPath 3750 format) must remain free.
A maximum of one board is permitted in HiPath 3350 and HiPath 3300. Two
HG 1500 boards can be installed if PDM1 is not being used.
When using an HXGS3 in HiPath 3350, the power supply unit PSUP must be re-
placed with UPSC-D.
It is not possible to operate an HXGS3 or HXGR3 and an LIM module simultaneously
in one system.
For information on configuration, refer to the HG 1500 Administration Manual.
Caution
7 When using an HXGS3 board in the upper slot row in HiPath 3550 (slots 4, 6, 8) or
HiPath 3350 (slot 4), fan kit C39165-A7021-D3 must be installed for thermal reasons
(see Page 3-113)!
The fan kit is not necessary when using an HXGS3 board in the lower slot row (slots
5, 7, 9 in HiPath 3550 and slot 5 in HiPath 3350).
The fan kit is not longer required in systems equipped with the following modified
housing covers.
● HiPath 3550 with housing cover C39165-A7021-B52 or higher
● HiPath 3350 with housing cover C39165-A7021-B53 or higher
For information on how to calculate the number of boards required for HG 1500, see
Section 2.6.8.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-107
boards.fm
Board versions
When using the extension module PDM1, the number of DSP channels for HXGS3
> and HXGR3 boards can be expanded by eight per board.
Extension modules
The HXGS3 and HXGR3 boards each have two HGA (HiPath Gateway Accelerator) slots,
which can be used to connect extension modules.
Table 3-44 HXGS3/HXGR3 - Extension Modules
P31003-H3560-S100-3-7620, 03/06
3-108 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-109
boards.fm
Interfaces/connectors
The HXGS3 and HXGR3 boards provide the following connectors:
● X1: 50-pin connector (edge connector) to the system
● X2: 8-pin RJ45 jack for LAN interface 1
● X3: 8-pin RJ45 jack for LAN interface 2
Both LAN interfaces allow access to the Ethernet standard (IEEE 802.3) with 10 Mbps or
100 Mbps with automatic configuration. Manual configuration is also possible.
● X4: 9-pin Sub-D plug for V.24 interface
LAN connectors: 50
LAN 1 (X2) HGA slot 1 HGA slot 0
To
LAN 2 (X3) CUC/
X1 CUCR or
CUP/
CUPR
2
V.24 interface X4
P31003-H3560-S100-3-7620, 03/06
3-110 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
LAN interfaces
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-111
boards.fm
V.24 interface
The V.24 cable (C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
P31003-H3560-S100-3-7620, 03/06
3-112 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Installing the fan kit for HXGS3 in HiPath 3550 or HiPath 3350
Caution
7 When using an HXGS3 board in the upper slot row in HiPath 3550 (slots 4, 6, 8) or
HiPath 3350 (slot 4), fan kit C39165-A7021-D3 must be installed for thermal rea-
sons!
The fan kit is not necessary when using an HXGS3 board in the lower slot row (slots
5, 7, 9 in HiPath 3550 and slot 5 in HiPath 3350).
The fan kit is not longer required in systems equipped with the following modified
housing covers.
● HiPath 3550 with housing cover C39165-A7021-B52 or higher
● HiPath 3350 with housing cover C39165-A7021-B53 or higher
Installing the fan kit marks the end of silent system operation. This must be taken
> into consideration when operating the system in an office environment.
Step Activity
1. Disconnect system from power supply.
Caution
System voltage can only be switched off by taking out the power plug. Switch off
the battery voltage first for an uninterruptible power supply.
2. Open the system.
Warning
Grasp the housing cover by its outside walls only.
The shielding plate on the inside of the cover may have sharp edges which can
cause cuts (see Section 4.4.3.4, “Removing the System Housing Cover”).
3. Place fan kit [A] on the system shelf [B] as shown in Figure 3-51.
4. Push the two supplied securing clips over positions [C] illustrated in Figure 3-52
to attach the fan kit to the shelf.
5. Insert the connector of the fan kit cable into the port provided for it on an HXGS3
board as illustrated in Figure 3-53.
6. Close the system.
Warning
Grasp the housing cover by its outside walls only.
7. Start the system by plugging in the power plug. In the case of an uninterruptible
power supply, the battery must then be switched on.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-113
boards.fm
[A]
[B]
P31003-H3560-S100-3-7620, 03/06
3-114 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
[C]
[D]
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-115
boards.fm
Introduction
The IVML8 and IVML24 (Integrated Voice Mail Large) boards allow you to use the HiPath
Xpressions Compact integrated voice mail functionality in HiPath 3750 and HiPath 3700 V1.2
or later. Music on Hold can be used in V4.0 SMR-7 or later and announcements in V5.0 or later.
In addition, the boards have an Ethernet (10/100BaseT) interface which can be used for HiPath
Xpressions Compact administration (fast APS transfer, backup and restore activities).
A maximum of one IVML8 or IVML24 is permitted for each HiPath 3750 and HiPath
> 3700. This board may only be inserted into the slot beside the power supply in the
basic cabinet or in the expansion cabinets. Furthermore, the ferrite bead (C39022-
Z7000-C7) included with the board must be mounted on the CABLU of the board that
is inserted to the immediate left of the IVML8 or IVML.
The rules provided under “Distribution of the PCM segments” on page 4-158 for pop-
ulation with boards must be observed to ensure the non-blocking operation of the
system.
For detailed information on HiPath Xpressions Compact, startup and administration, see the
manual for the product (see Section 1.6, “Information on the Intranet”: Electronic Documenta-
tion on Com ESY Products).
P31003-H3560-S100-3-7620, 03/06
3-116 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-117
boards.fm
Lockout switch
(position = free, factory default)
LED (green)
LED (yellow)
P31003-H3560-S100-3-7620, 03/06
3-118 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-119
boards.fm
LAN adapter
The Ethernet LAN interface is accessed via the LAN adapter shown in Figure 3-56 (part no.
C39228-A7195-A10), which is connected on the backplane’s (Xx9) SIPAC 1 SU connector.
Only shielded cables may be used for the LAN connector (RJ45 jack).
SIPAC 1 SU
jack (Xx9
backplane)
RJ45
jack
(LAN)
P31003-H3560-S100-3-7620, 03/06
3-120 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The IVMNL and IVMNL8 (Integrated Voice Mail New Large) boards allow you to use the HiPath
Xpressions Compact integrated voice mail functionality in HiPath 3800:
● IVMNL (S30122-H7688-X) = 24 ports
● IVMN8 (S30122-H7688-X100) = 8 ports
The boards can also be used for Music on Hold and announcements.
For detailed information on HiPath Xpressions Compact, startup and administration, see the
manual for the product (see Section 1.6, “Information on the Intranet”: Electronic Documenta-
tion on Com ESY Products).
Caution
7 In a HiPath 3800 19-inch cabinet configuration, the IVMNL board may only be in-
stalled in the basic cabinet to avoid overheating.
Only one IVMNL or IVMN8 may be installed per HiPath 3800 system.
> To avoid inactive IVM channels caused by slow IVM board startup, the following rec-
ommendations must be followed:
● IVMNL:
– Installing HiPath 3800 as a standalone system: The IVMNL board should be
installed in the last slot of the last system cabinet. If possible, the two pre-
ceding slots should be kept empty.
– Installing HiPath 3800 in a 19-inch cabinet: The IVMNL board should be in-
stalled in the last slot of the basic cabinet. If possible, the two preceding
slots should be kept empty.
● IVMN8:
Installing HiPath 3800 (standalone) or HiPath 3800 (19-inch cabinet): The
IVMN8 board should be installed in the last slot of the last system cabinet. If pos-
sible, the two preceding slots should be kept empty.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-121
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-122 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Front panel
Lockout switch
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-123
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-124 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-125
boards.fm
Introduction
The following boards are used for the integrated voice mail functionality in HiPath Xpressions
Compact in V1.2 and later:
● IVMP8 (Integrated Voice Mail Point) S30122-Q7379-X100 - for HiPath 3350 (wall housing)
● IVMP8R (Integrated Voice Mail Point Rack) S30122-K7379-Z100 - for HiPath 3300 (19-
inch housing)
Music on Hold can be used in V4.0 SMR-7 or later and announcements in V5.0 or later.
In addition, the boards have an Ethernet (10/100BaseT) interface which can be used for HiPath
Xpressions Compact administration (fast APS transfer, backup and restore activities).
For detailed information on HiPath Xpressions Compact, startup and administration, see the
manual for the product (see Section 1.6, “Information on the Intranet”: Electronic Documenta-
tion on Com ESY Products).
P31003-H3560-S100-3-7620, 03/06
3-126 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Figure 3-59 IVMP8 and IVMP8R (not for U.S.) - Packing Protection Covering
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-127
boards.fm
2 50
X4
10
Lockout switch X1 = con-
LED (green) nection to
X1 CUP/
LED (yellow)
X3 = LAN CUPR
connector, X3
8-pin RJ45
jack 2
X2 2
10
P31003-H3560-S100-3-7620, 03/06
3-128 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-129
boards.fm
Table 3-52 IVMP8 and IVMP8R (not for U.S.) - LED Statuses
P31003-H3560-S100-3-7620, 03/06
3-130 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The following boards are used for the integrated voice mail functionality in HiPath Xpressions
Compact in V1.2 and later:
● IVMS8 (Integrated Voice Mail Small) S30122-Q7379-X - for HiPath 3550 and HiPath 3350
(wall housing)
● IVMS8R (Integrated Voice Mail Small Rack) S30122-K7379-Z - for HiPath 3500 and HiPath
3300 (19-inch housing)
Music on Hold can be used in V4.0 SMR-7 or later and announcements in V5.0 or later.
In addition, the boards have an Ethernet (10/100BaseT) interface which can be used for HiPath
Xpressions Compact administration (fast APS transfer, backup and restore activities).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-131
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-132 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
2 50
X4
10
Lockout switch X1 = con-
LED (green) nection to
X1 CUC/
LED (yellow)
X3 = LAN CUCR/
connector, X3 CUP/
8-pin RJ45 CUPR
jack 2
X2 2
10
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-133
boards.fm
LED (yellow)
LED (green)
Lockout switch
P31003-H3560-S100-3-7620, 03/06
3-134 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-135
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-136 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The PBXXX (Peripheral Board XXX) module can be used in HiPath 3800 to support country-
specific CAS protocols.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connec-
> tors. Since the PBXXX2 board has SIVAPAC connector strips, you will have to install
a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.
For information on this procedure, please see Section 4.2.5.5.
The PBXXX board converts the Euro-ISDN protocol on an S2M link into the Channel Associated
Signaling (CAS) protocol. The board functions only in conjunction with a DIUN2. There is no
direct connection between the PBXXX board and the system’s central control unit. The DIUN2
handles all signaling and data traffic.
The following combination options are possible:
● 1 x DIUN2 + 1 x PBXXX (see Page 3-140)
The PBXXX board must be plugged in on the left next to the DIUN2.
● 1 x DIUN2 + 2 x PBXXX (see Page 3-143)
The PBXXX boards must be plugged in on the left and right next to the DIUN2.
Up to four PBXXX boards can be installed in a HiPath 3800. For power supply reasons, a max-
imum of two PBXXX can be installed in a cabinet.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-137
boards.fm
Front panel
Seven-segment display
Figure 3-64 PBXXX (S30810-Q6401-X) (for selected countries only) - Front Panel
P31003-H3560-S100-3-7620, 03/06
3-138 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Seven-segment display
The board statuses listed in the following table are displayed.
Table 3-55 PBXXX (for selected countries only) - Seven-segment display
Display Meaning
Waiting for the PBXXX software download
Boot procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-139
boards.fm
Cable to service PC
The CAS cable is connected to the backplane using an APPCU adapter (see Figure 3-66).
P31003-H3560-S100-3-7620, 03/06
3-140 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Figure 3-66 PBXXX (for selected countries only) - Connecting the CAS Cable Using the
APPCU Adapter
The backplane of the PBXXX board must be closed with the adapter panels provided
> (C39165-A7050-C35, Figure 3-67).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-141
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-142 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Cable to service PC
The CAS cables are connected to the backplane using two APPCU adapters (see Figure 3-
69).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-143
boards.fm
Figure 3-69 PBXXX (for selected countries only) - Connecting the CAS Cable Using Two
APPCU Adapters
The backplane of both PBXXX boards must be closed with the adapter panels pro-
> vided (C39165-A7050-C35, Figure 3-67).
P31003-H3560-S100-3-7620, 03/06
3-144 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-145
boards.fm
Introduction
The peripheral boards
● SLA8N (Subscriber Line Analog) with eight analog T/R interfaces (not for U.S.)
● SLA16N (16 analog interfaces)
● SLA24N (24 analog interfaces)
can be used in HiPath 3750, HiPath 3550 and HiPath 3700.
H1 (green)
LEDs
H2 (red)
Lockout switch S1
(position = free, factory default)
Figure 3-70 SLA8N (not for U.S.), SLA16N, SLA24N (S30810-Q2929-X200, -X100, -X)
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu Settings: Set up station –>
Station –> Parameters –> Flags).
P31003-H3560-S100-3-7620, 03/06
3-146 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-58 SLA8N (Not For U.S.), SLA16N, SLA24N - LED Statuses
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-147
boards.fm
Table 3-59 SLA8N, SLA16N, SLA24N Assignment Cable 1 (SU Xx8) (Not for U.S.)
SU SLA8N, Patch
Color a-Wire b-Wire connector MDFU/
Pair SLA16N, panel, Notes
group (Tip) (Ring) MDFU-E
BP: Xx8 SLA24N MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 Port 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 Port 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 Port 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 Port 12 Not
ora/blk 24 12b 12b 5 used
blk/grn 15 13a 13a 4 in
3 13 Port 13 SLA8N
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 Port 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 Port 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 Port 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
3-148 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-60 SLA8N, SLA16N, SLA24N - Assignment Cable 2 (SU Xx9) (Not for U.S.)
SU SLA8N, Patch
Color a-Wire b-Wire connector MDFU/
Pair SLA16N, panel, Notes
group (Tip) (Ring) MDFU-E
BP: Xx9 SLA24N MW8 pin
wht/blu
1 Free
blu/wht
wht/ora
2 Free
ora/wht
wht/grn
1 3 Free
grn/wht
wht/brn
4 Free
brn/wht
wht/gry
5 Free
gry/wht
red/blu
6 Free
blu/red
red/ora
7 Free
ora/red
red/grn
2 8 Free
grn/red
red/brn 11 17a 17a 4
9 Port 17
brn/red 31 17b 17b 5
red/gry 02 18a 18a 4
10 Port 18
gry/red 22 18b 18b 5
blk/blu 13 19a 19a 4
11 Port 19
blu/blk 33 19b 19b 5
blk/ora 04 20a 20a 4 not
12 Port 20 used
ora/blk 24 20b 20b 5
in
blk/grn 15 21a 21a 4 SLA8N,
3 13 Port 21
grn/blk 35 21b 21b 5 SLA16N
blk/brn 06 22a 22a 4
14 Port 22
brn/blk 26 22b 22b 5
blk/gry 17 23a 23a 4
15 Port 23
gry/blk 37 23b 23b 5
yel/blu 08 24a 24a 4
4 16 Port 24
blu/yel 28 24b 24b 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-149
boards.fm
Table 3-61 SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (For U.S. Only)
a-Wire b-Wire SU connector SLA16N,
# CHAMP jack, MDF Notes
(Tip) (Ring) BP: Xx8 BP: Xx9 SLA24N
wht/blu 19 1a 1 1a
1 Port 1
blu/wht 39 1b 26 1b
wht/ora 38 2a 2 2a
2 Port 2
ora/wht 48 2b 27 2b
wht/grn 27 3a 3 3a
3 Port 3
grn/wht 47 3b 28 3b
wht/brn 16 4a 4 4a
4 Port 4
brn/wht 46 4b 29 4b
wht/gry 05 5a 5 5a
5 Port 5
gry/wht 45 5b 30 5b
red/blu 14 6a 6 6a
6 Port 6
blu/red 44 6b 31 6b
red/ora 23 7a 7 7a
7 Port 7
ora/red 43 7b 32 7b
red/grn 32 8a 8 8a
8 Port 8
grn/red 42 8b 33 8b
red/brn 11 9a 9 9a
9 Port 9
brn/red 31 9b 34 9b
red/gry 02 10a 10 10a
10 Port 10
gry/red 22 10b 35 10b
blk/blu 13 11a 11 11a
11 Port 11
blu/blk 33 11b 36 11b
blk/ora 04 12a 12 12a
12 Port 12
ora/blk 24 12b 37 12b
blk/grn 15 13a 13 13a
13 Port 13
grn/blk 35 13b 38 13b
blk/brn 06 14a 14 14a
14 Port 14
brn/blk 26 14b 39 14b
blk/gry 17 15a 15 15a
15 Port 15
gry/blk 37 15b 40 15b
yel/blu 08 16a 16 16a
16 Port 16
blu/yel 28 16b 41 16b
P31003-H3560-S100-3-7620, 03/06
3-150 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-61 SLA16N, SLA24N - Assignment (SU Xx8, Xx9) (For U.S. Only)
a-Wire b-Wire SU connector SLA16N,
# CHAMP jack, MDF Notes
(Tip) (Ring) BP: Xx8 BP: Xx9 SLA24N
red/brn 11 17a 9 9a
17 Port 17
brn/red 31 17b 34 9b
red/gry 02 18a 10 10a
18 Port 18
gry/red 22 18b 35 10b
blk/blu 13 19a 11 11a
19 Port 19
blu/blk 33 19b 36 11b
blk/ora 04 20a 12 12a
20 Port 20 Not
ora/blk 24 20b 37 12b used
blk/grn 15 21a 13 13a in
21 Port 21 SLA16N
grn/blk 35 21b 38 13b
blk/brn 06 22a 14 14a
22 Port 22
brn/blk 26 22b 39 14b
blk/gry 17 23a 15 15a
23 Port 23
gry/blk 37 23b 40 15b
yel/blu 08 24a 16 16a
24 Port 24
blu/yel 28 24b 41 16b
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-151
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-152 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The SLC16N board connects base stations for HiPath Cordless Office to
● HiPath 3750 and HiPath 3700 (max. four SLC16Ns per system).
● HiPath 3550 (max. one SLC16N per system).
Chapter 11 contains basic information on the options available for the use of HiPath Cordless
Office.
For initial installation of the HiPath Cordless Office, the HiPath cordless system num-
> ber (DECT ID) must be ordered together with the SLC16N board.
Replacement boards are always delivered without a HiPath cordless system num-
ber.
Installing the SLC16N and entering the HiPath cordless system number releases 16
mobile units for use (PIN numbers are assigned). These mobile units can then be
logged on to the system. Any additional mobile units to be used must first be re-
leased (see Section 10.12.6).
Base stations must be clocked with a high degree of accuracy for HiPath Cordless Office. Install
the plug-in CMS subboard on the CBCPR board (HiPath 3750 and HiPath 3700) or the plug-in
CMA or CMS subboard on the CBCC board (for HiPath 3550) to ensure clock accuracy (see
Table 11-1).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-153
boards.fm
LED (green)
LED (red)
Lockout switch
(Not pressed = free,
factory default)
Activate the lockout switch (Press switch), all idle cordless phones are blocked. Ac-
> tive mobile telephones are not locked until their release keys are pressed.
Before unplugging the SLC16N board, always activate the lockout switch and wait
until green LED stops flashing. This precaution ensures that none of the mobile tele-
phones are active.
P31003-H3560-S100-3-7620, 03/06
3-154 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-155
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-156 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
To guarantee uninterrupted operation of HiPath 3750 and HiPath 3700, the SLC16N
> should not be installed with a second SLC16N, an SLMO24 or a TS2 on a PCM seg-
ment. This condition must always be observed.
For information on PCM segment distribution, see Page 4-158.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-157
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-158 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
● HiPath 3550
Subject to certain prerequisites, the system-internal PSU UPSC-D provides sufficient pow-
er for the operation of sixteen BS3/1s (one UP0/E each) or eight BS2/2s and BS3/3s (two
UP0/E each). These prerequisites depend on the
– Line length and line type between SLC16N and base station.
The following specifications are based on line lengths of up to 1000 m and a line type
2x0.6 mm per UP0/E.
– Number and type of corded telephones connected to the system.
Table 3-65 through Table 3-67 show which telephone configurations work without ad-
ditional power supply.
Table 3-65 HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/1 Base Stations Connected to SLC16N and BS4 connect-
ed to SLC16N (not for U.S)
Number Maximum number of corded telephones
of BS3/1s and BS4s analog telephones
connected via 1xUP0/E
0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
to
SLC16N optiset E and optiPoint 500 telephones
1 66 61 57 53 48 44
2 63 59 54 50 46 41
3 60 56 52 47 43 39
4 58 53 49 45 40 36
5 55 51 47 42 38 33
6 53 48 44 40 35 31
7 50 46 41 37 33 28
8 47 43 39 34 30 26
9 45 40 36 32 27 23
10 42 38 33 29 25 20
11 40 35 31 27 22 18
12 37 33 28 24 20 15
13 34 30 26 21 17 13
14 32 27 23 19 14 10
15 29 25 20 16 12 7
16 27 22 18 13 9 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-159
boards.fm
Table 3-66 HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS2/2 Base Stations Connected to SLC16N (Not for U.S.)
Number Maximum number of corded telephones
of BS2/2s analog telephones
on
SLC16N 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
optiset E and optiPoint 500 telephones
1 63 59 54 50 46 41
2 58 53 49 45 40 36
3 53 48 44 40 35 31
4 47 43 39 34 30 26
5 42 38 33 29 25 20
6 37 33 28 24 20 15
7 32 27 23 19 14 10
8 27 22 18 13 9 5
Table 3-67 HiPath 3550 - Maximum Number of Corded Telephones Depending on the
Number of BS3/3 Base Stations Connected to SLC16N and BS4 connect-
ed to SLC16N (not for U.S)
Number Maximum number of corded telephones
of BS3/3s and BS4s analog telephones
connected via 2xUP0/E
to 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
SLC16N optiset E and optiPoint 500 telephones
1 64 60 56 51 47 42
2 60 56 52 47 43 39
3 57 52 48 43 39 35
4 53 48 44 40 35 31
5 49 44 40 36 31 27
6 45 40 36 32 27 23
7 41 37 32 28 23 19
8 37 33 28 24 20 15
P31003-H3560-S100-3-7620, 03/06
3-160 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
For information on connecting the base stations, refer to the HiPath Cordless Office
> service manual.
Each base station must be connected to the SLC16N via the main distribution frame (MDFU or
MDFU-E).
Always route the UP0/E interfaces on the SLC16N via a splitting strip to ensure that surges due
to lightning will be arrested. To do so, insert the polarized surge protectors (supplied) in the
plugging locations on the splitting strip from above.
The following options are available for supplying power to the base stations:
● Power supply via one UP0/E interface (Page 3-162)
● Power supply via two UP0/E interfaces (Page 3-163)
● Power supply via three UP0/E interfaces (Page 3-164), for BS3/3 only
If the power supplied by the UPSC-D (HiPath 3550) is insufficient, additional power can be sup-
plied by installing the external power supply EPSU2 (Page 3-164).
Signal propagation times differ due to the varying distances between the base stations, the sys-
tem, and the connection cables used (refer to the HiPath Cordless Office service manual). The
SLC16N board automatically balances these propagation times.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-161
boards.fm
Splitting a
strip b
1
MDFU, MDFU-E
Figure 3-72 Base Station Power Supply via One UP0/E Interface (Not for U.S.)
P31003-H3560-S100-3-7620, 03/06
3-162 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Splitting a
strip b
1
MDFU, MDFU-E
Figure 3-73 Base Station Power Supply via Two UP0/E Interfaces (Not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-163
boards.fm
Splitting a
strip b
1
MDFU, MDFU-E
Figure 3-74 Base Station Power Supply via Three UP0/E Interfaces (Not for U.S.)
P31003-H3560-S100-3-7620, 03/06
3-164 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-165
boards.fm
Battery fuse
LED 1 Mounting
screws
LED 2
P31003-H3560-S100-3-7620, 03/06
3-166 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
EPSU2 EPSU2
S30122-K7221-X1 S30122-K7221-X2
Scope of delivery ● EPSU2 AC/DC converter ● EPSU2 AC/DC converter
with four UPS batteries without batteries
loaded ● Operating instructions
● Operating instructions ● AC connecting cable (pro-
● AC connecting cable (pro- tective grounding plug,
tective grounding plug, IEC-320 socket)
IEC-320 socket) ● DC cable to UPSC-D
● DC cable to UPSC-D (length = 2 m)
(length = 2 m)
AC power cable ● C39195-Z7001-C17 Euro angled
● C39195-Z7001-C20 GBR angled
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-167
boards.fm
EPSU2 EPSU2
S30122-K7221-X1 S30122-K7221-X2
AC power 100 - 240 V AC
Frequency range 47 to 63 Hz
Connected output 200 W
Output power consumption/ 140 W
nominal output
Mains/nominal voltage 54.2 V
UPS batteries V39113-W5123-E891 V39113-W5123-E891
Four batteries are supplied Batteries are not included in
built-in. the scope of supply and must
be ordered separately.
Battery operation:
● Permitted batteries ● CSB/EVX-1270, Hitachi/HP6.5-12, Yuasa/NP6-12, Varta/
Manufacturer/type num- Noack 43720303, Sonnenschein/0719143200, Panasonic/
ber LCR12-7P
● Number of batteries ● 4 units, 12 V each
● Size (Ah) ● 7 Ah
● Nominal voltage ● 48 V (fully charged 54 V, discharge to 44 V)
● Overload protection ● Melting fuse 5 x 20 mm, 2.5 A/slow-blowing
Nominal current 2.5 A
Overload protection Electronic current limiting circuit
Ambient temperature In buildings, +5 to +45 °C (41 to 113 °F)
Humidity 95%, non-condensing
Cooling Natural convection
Protection IP 21 (DIN 40050)
Housing dimensions (W x D 250 x 114 x 317
x H in mm)
Weight approx. 14.1 kg (incl. batteries) approx. 4.1 kg (without batter-
ies)
Symbol CE
Personal safety, insulation EN60950 and IEC950
Grounding, shielding Protection class 1, output is floating against ground
P31003-H3560-S100-3-7620, 03/06
3-168 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Installation notes
● The EPSU2 AC/DC converter is designed for installation indoors only.
● The unit is suitable only for mounting on the wall (vertically, with AC port on bottom).
● Always install the units in a dry, dust-free area where there is no danger of vibrations.
● Always make sure there is sufficient air circulation around the units. Do not block the ven-
tilation holes.
● When selecting the location, keep in mind the necessary lengths of the following cables:
– AC cable (grounding plug, IEC 320 socket)
– DC cable to UPSC-D, length = 2 m
Procedure: EPSU2 wall-mounting
Step Activity
1. Drill two holes for anchors (5 mm in diameter) in the wall, as shown in Figure 3-76.
Depending on the wall materials, you may have to use a different kind of attach-
ment, such as wood screws for timber walls.
2. Insert the anchors and insert two screws (3.5 mm in diameter), leaving 5 mm pro-
jecting from the wall.
3. Mount the EPSU2 onto the screws and tighten them all the way.
115 mm 102 mm 33 mm
317 mm
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-169
boards.fm
Introduction
The SLCN (Subscriber Line Module Cordless New) board is used in HiPath 3800 and connects
base stations to HiPath Cordless Office. There are 16 UP0/E ports available for this.
You can install up to four SLCN boards in one system.
Chapter 11 contains basic information on the options available for operating HiPath Cordless
Office.
Base stations must be clocked with a high degree of accuracy for HiPath Cordless Office. For
this, the subboard CMS must be plugged into the CBSAP board (see Table 11-1).
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
3-170 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-171
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-172 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-173
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-174 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-73 SLCN - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for
Ports 1 - 16)
Patch
Color a-Wire b-Wire SU
Pair SLCN MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 Port 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 Port 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 Port 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 Port 12
ora/blk 24 12b 12b 5
blk/grn 15 13a 13a 4
3 13 Port 13
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 Port 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 Port 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 Port 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-175
boards.fm
To guarantee uninterrupted operation of the HiPath 3800, not more than two SLCN
> boards should be plugged in to a PCM segment. This condition must always be ob-
served. For information on PCM segment distribution, see Section 4.2.5.7.
One board slot should be kept free between two SCLN boards to prevent overheat-
ing.
P31003-H3560-S100-3-7620, 03/06
3-176 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The SLMA and SLMA8 (Subscriber Line Module Analog) boards provide analog T/R interfaces
for use in HiPath 3800:
● SLMA (S30810-Q2191-C300) = 24 analog T/R interfaces
● SLMA8 (S30810-Q2191-C100) = eight analog T/R interfaces
The boards generate their own ring voltages and do not require an external ring voltage gen-
erator.
Caution
7 The ring voltage is 35 Veff. Depending on the connected terminals, malfunctions may
occur (for example the MWI signal may not be recognized).
If a higher ring voltage is required, the SLMA2 board can be used with the RGMOD
ring voltage generator.
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-177
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-178 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-179
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-180 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-181
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-182 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-77 SLMA/SLMA8 - Connector Panel Assignment with CHAMP Jack (For U.S.
Only)
CHAMP jack SLMA, SLMA8 Notes
1 1a 1 Ring
Port 1
26 1b 1 TIP
2 2a 2 Ring
Port 2
27 2b 2 TIP
3 3a 3 Ring
Port 3
28 3b 3 TIP
4 4a 4 Ring
Port 4
29 4b 4 TIP
5 5a 5 Ring
Port 5
30 5b 5 TIP
6 6a 6 Ring
Port 6
31 6b 6 TIP
7 7a 7 Ring
Port 7
32 7b 7 TIP
8 8a 8 Ring
Port 8
33 8b 8 TIP
9 9a 9 Ring
Port 9
34 9b 9 TIP
10 10a 10 Ring
Port 10
35 10b 10 TIP
11 11a 11 Ring
Port 11
36 11b 11 TIP
12 12a 12 Ring
Port 12 Not
37 12b 12 TIP used
13 13a 13 Ring in
Port 13 SLMA8
38 13b 13 TIP
14 14a 14 Ring
Port 14
39 14b 14 TIP
15 15a 15 Ring
Port 15
40 15b 15 TIP
16 16a 16 Ring
Port 16
41 16b 16 TIP
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-183
boards.fm
Table 3-77 SLMA/SLMA8 - Connector Panel Assignment with CHAMP Jack (For U.S.
Only)
CHAMP jack SLMA, SLMA8 Notes
17 17a 17 Ring
Port 17
42 17b 17 TIP
18 18a 18 Ring
Port 18
43 18b 18 TIP
19 19a 19 Ring
Port 19
44 19b 19 TIP
20 20a 20 Ring
Port 20 Not
45 20b 20 TIP used
21 21a 21 Ring in
Port 21 SLMA8
46 21b 21 TIP
22 22a 22 Ring
Port 22
47 22b 22 TIP
23 23a 23 Ring
Port 23
48 23b 23 TIP
24 24a 24 Ring
Port 24
49 24b 24 TIP
P31003-H3560-S100-3-7620, 03/06
3-184 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-78 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors
(Cable for Ports 1 - 16)
Patch
Color a-Wire b-Wire SU
Pair SLMA, SLMA8 MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 Port 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 Port 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 Port 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 Port 12 Not
ora/blk 24 12b 12b 5 used
blk/grn 15 13a 13a 4 in
3 13 Port 13 SLMA8
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 Port 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 Port 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 Port 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-185
boards.fm
Table 3-79 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors
(Cable for Ports 17 - 24)
Patch
Color a-Wire b-Wire SU
Pair SLMA, SLMA8 MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu
1 Free
blu/wht
wht/ora
2 Free
ora/wht
wht/grn
1 3 Free
grn/wht
wht/brn
4 Free
brn/wht
wht/gry
5 Free
gry/wht
red/blu
6 Free
blu/red
red/ora
7 Free
ora/red
red/grn
2 8 Free
grn/red
red/brn 11 17a 17a 4
9 Port 17
brn/red 31 17b 17b 5
red/gry 02 18a 18a 4
10 Port 18
gry/red 22 18b 18b 5
blk/blu 13 19a 19a 4
11 Port 19
blu/blk 33 19b 19b 5
blk/ora 04 20a 20a 4
12 Port 20 Not
ora/blk 24 20b 20b 5 used
blk/grn 15 21a 21a 4 in
3 13 Port 21 SLMA8
grn/blk 35 21b 21b 5
blk/brn 06 22a 22a 4
14 Port 22
brn/blk 26 22b 22b 5
blk/gry 17 23a 23a 4
15 Port 23
gry/blk 37 23b 23b 5
yel/blu 08 24a 24a 4
4 16 Port 24
blu/yel 28 24b 24b 5
P31003-H3560-S100-3-7620, 03/06
3-186 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The SLMA2 (Subscriber Line Module Analog) board provides analog T/R interfaces for use in
HiPath 3800.
The external ring voltage generator RGMOD (S30124-X5109-X) is required for generating ring
voltages. RGMOD is plugged in on the backplane of the basic and/or expansion cabinet. The
ring voltage and ring frequency are set using jumpers.
A system cabinet can be fitted with a mix of SLMA, SLMA8 and SLMA2 boards. RG-
> MOD has no effect on SLMA and SLMA8, as these boards generate their own ring
voltage (35 Veff).
Front panel
Figure 3-79 SLMA2 (S30810-Q2246-X) (for selected countries only) - LED’s on the Front
Panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-187
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-188 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-81 SLMA2 (for selected countries only) - SIVAPAC Connector Assignment on the
Backplane
a-wire b-wire
Pair SIVAPAC connector SLMA2 MDFU-E Notes
(tip) (ring)
wht/blu 1 1a 1a
1 port 1
blu/wht 23 1b 1b
wht/ora 3 2a 2a
2 port 2
ora/wht 4 2b 2b
wht/grn 5 3a 3a
3 port 3
grn/wht 6 3b 3b
wht/brn 7 4a 4a
4 port 4
brn/wht 8 4b 4b
wht/gry 9 5a 5a
5 port 5
gry/wht 10 5b 5b
red/blu 11 6a 6a
6 port 6
blu/red 12 6b 6b
red/ora 13 7a 7a
7 port 7
ora/red 14 7b 7b
red/grn 15 8a 8a
8 port 8
grn/red 16 8b 8b
red/brn 17 9a 9a
9 port 9
brn/red 18 9b 9b
red/gry 19 10a 10a
10 port 10
gry/red 20 10b 10b
blk/blu 24 11a 11a
11 port 11
blu/blk 25 11b 11b
blk/ora 26 12a 12a
12 port 12
ora/blk 27 12b 12b
blk/grn 29 13a 13a
13 port 13
grn/blk 30 13b 13b
blk/brn 31 14a 14a
14 port 14
brn/blk 32 14b 14b
blk/gry 34 15a 15a
15 port 15
gry/blk 35 15b 15b
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-189
boards.fm
Table 3-81 SLMA2 (for selected countries only) - SIVAPAC Connector Assignment on the
Backplane
a-wire b-wire
Pair SIVAPAC connector SLMA2 MDFU-E Notes
(tip) (ring)
yel/blu 37 16a 16a
16 port 16
blu/yel 38 16b 16b
yel/ora 43 17a 17a
17 port 17
ora/yel 44 17b 17b
yel/grn 45 18a 18a
18 port 18
grn/yel 46 18b 18b
yel/brn 47 19a 19a
19 port 19
brn/yel 48 19b 19b
yel/gry 49 20a 20a
20 port 20
gry/yel 50 20b 20b
vio/blu 51 21a 21a
21 port 21
blu/vio 52 21b 21b
vio/ora 53 22a 22a
22 port 22
ora/vio 54 22b 22b
vio/grn 55 23a 23a
23 port 23
grn/vio 56 23b 23b
vio/brn 57 24a 24a
24 port 24
brn/vio 58 24b 24b
P31003-H3560-S100-3-7620, 03/06
3-190 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-82 SLMA2 (for selected countries only) - Connector Panel Assignment with RJ45
Jacks
RJ45 jack
SLMA2 Notes
No. Pin
4 1a
1
5 1b
4 2a
2
5 2b
4 3a
3
5 3b
4 4a
4
5 4b
4 5a
5
5 5b
4 6a
6
5 6b
4 7a
7
5 7b
4 8a
8
5 8b
4 9a
9
5 9b
4 10a
10
5 10b
4 11a
11
5 11b
4 12a
12
5 12b
4 13a
13
5 13b
4 14a
14
5 14b
4 15a
15
5 15b
4 16a
16
5 16b
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-191
boards.fm
Table 3-82 SLMA2 (for selected countries only) - Connector Panel Assignment with RJ45
Jacks
RJ45 jack
SLMA2 Notes
No. Pin
4 17a
17
5 17b
4 18a
18
5 18b
4 19a
19
5 19b
4 20a
20
5 20b
4 21a
21
5 21b
4 22a
22
5 22b
4 23a
23
5 23b
4 24a
24
5 24b
P31003-H3560-S100-3-7620, 03/06
3-192 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-83 SLMA2 (for selected countries only) - Connector Panel Assignment with
CHAMP Jacks (U.S. only)
CHAMP jack SLMA2 Notes
1 1a 1 Ring
port 1
26 1b 1 TIP
2 2a 2 Ring
port 2
27 2b 2 TIP
3 3a 3 Ring
port 3
28 3b 3 TIP
4 4a 4 Ring
port 4
29 4b 4 TIP
5 5a 5 Ring
port 5
30 5b 5 TIP
6 6a 6 Ring
port 6
31 6b 6 TIP
7 7a 7 Ring
port 7
32 7b 7 TIP
8 8a 8 Ring
port 8
33 8b 8 TIP
9 9a 9 Ring
port 9
34 9b 9 TIP
10 10a 10 Ring
port 10
35 10b 10 TIP
11 11a 11 Ring
port 11
36 11b 11 TIP
12 12a 12 Ring
port 12
37 12b 12 TIP
13 13a 13 Ring
port 13
38 13b 13 TIP
14 14a 14 Ring
port 14
39 14b 14 TIP
15 15a 15 Ring
port 15
40 15b 15 TIP
16 16a 16 Ring
port 16
41 16b 16 TIP
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-193
boards.fm
Table 3-83 SLMA2 (for selected countries only) - Connector Panel Assignment with
CHAMP Jacks (U.S. only)
CHAMP jack SLMA2 Notes
17 17a 17 Ring
port 17
42 17b 17 TIP
18 18a 18 Ring
port 18
43 18b 18 TIP
19 19a 19 Ring
port 19
44 19b 19 TIP
20 20a 20 Ring
port 20
45 20b 20 TIP
21 21a 21 Ring
port 21
46 21b 21 TIP
22 22a 22 Ring
port 22
47 22b 22 TIP
23 23a 23 Ring
port 23
48 23b 23 TIP
24 24a 24 Ring
port 24
49 24b 24 TIP
P31003-H3560-S100-3-7620, 03/06
3-194 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-84 SLMA2 (for selected countries only) - Connector Panel Assignment with
SIPAC 1 SU Connectors (Cable for Ports 1 - 16)
Color a-wire b-wire SU con- Patch Panel,
Pair SLMA2 MDFU-E Notes
group (tip) (ring) nector MW8 pin
wht/blu 19 1a 1a 4
1 port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 port 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 port 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 port 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 port 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 port 12
ora/blk 24 12b 12b 5
blk/grn 15 13a 13a 4
3 13 port 13
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 port 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 port 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 port 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-195
boards.fm
Table 3-85 SLMA2 (for selected countries only) - Connector Panel Assignment with
SIPAC 1 SU Connectors (Cable for Ports 17 - 24)
Color a-wire b-wire SU con- Patch Panel,
Pair SLMA2 MDFU-E Notes
group (tip) (ring) nector MW8 pin
wht/blu
1 free
blu/wht
wht/ora
2 free
ora/wht
wht/grn
1 3 free
grn/wht
wht/brn
4 free
brn/wht
wht/gry
5 free
gry/wht
red/blu
6 free
blu/red
red/ora
7 free
ora/red
red/grn
2 8 free
grn/red
red/brn 11 17a 17a 4
9 port 17
brn/red 31 17b 17b 5
red/gry 02 18a 18a 4
10 port 18
gry/red 22 18b 18b 5
blk/blu 13 19a 19a 4
11 port 19
blu/blk 33 19b 19b 5
blk/ora 04 20a 20a 4
12 port 20
ora/blk 24 20b 20b 5
blk/grn 15 21a 21a 4
3 13 port 21
grn/blk 35 21b 21b 5
blk/brn 06 22a 22a 4
14 port 22
brn/blk 26 22b 22b 5
blk/gry 17 23a 23a 4
15 port 23
gry/blk 37 23b 23b 5
yel/blu 08 24a 24a 4
4 16 port 24
blu/yel 28 24b 24b 5
P31003-H3560-S100-3-7620, 03/06
3-196 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The SLMO2 and SLMO8 boards (Subscriber Line Module Optiset) provide UP0/E interfaces for
use in HiPath 3800:
● SLMO2 (S30810-Q2168-X10) = 24 UP0/E interfaces
● SLMO8 (S30810-Q2168-X100) = eight UP0/E interfaces
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-197
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-198 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-199
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-200 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-201
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-202 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-89 SLMO2/SLMO8 - Connector Panel Assignment with CHAMP Jack (For U.S.
Only)
CHAMP jack SLMO2, SLMO8 Notes
1 1a 1 Ring
Port 1
26 1b 1 TIP
2 2a 2 Ring
Port 2
27 2b 2 TIP
3 3a 3 Ring
Port 3
28 3b 3 TIP
4 4a 4 Ring
Port 4
29 4b 4 TIP
5 5a 5 Ring
Port 5
30 5b 5 TIP
6 6a Ring
Port 6
31 6b 6 TIP
7 7a 7 Ring
Port 7
32 7b 7 TIP
8 8a 8 Ring
Port 8
33 8b 8 TIP
9 9a 9 Ring
Port 9
34 9b 9 TIP
10 10a 10 Ring
Port 10
35 10b 10 TIP
11 11a 11 Ring
Port 11
36 11b 11 TIP
12 12a 12 Ring
Port 12
37 12b 12 TIP Not used for
13 13a 13 Ring SLMO8
Port 13
38 13b 13 TIP
14 14a 14 Ring
Port 14
39 14b 14 TIP
15 15a 15 Ring
Port 15
40 15b 15 TIP
16 16a 16 Ring
Port 16
41 16b 16 TIP
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-203
boards.fm
Table 3-89 SLMO2/SLMO8 - Connector Panel Assignment with CHAMP Jack (For U.S.
Only)
CHAMP jack SLMO2, SLMO8 Notes
17 17a 17 Ring
Port 17
42 17b 17 TIP
18 18a 18 Ring
Port 18
43 18b 18 TIP
19 19a 19 Ring
Port 19
44 19b 19 TIP
20 20a 20 Ring
Port 20
45 20b 20 TIP Not used for
21 21a 21 Ring SLMO8
Port 21
46 21b 21 TIP
22 22a 22 Ring
Port 22
47 22b 22 TIP
23 23a 23 Ring
Port 23
48 23b 23 TIP
24 24a 24 Ring
Port 24
49 24b 24 TIP
P31003-H3560-S100-3-7620, 03/06
3-204 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-205
boards.fm
Table 3-91 SLMA, SLMA8 - Connector Panel Assignment with SIPAC 1 SU Connectors
(Cable for Ports 17 - 24)
Patch
Color a-Wire b-Wire SU
Pair SLMA, SLMA8 MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu
1 Free
blu/wht
wht/ora
2 Free
ora/wht
wht/grn
1 3 Free
grn/wht
wht/brn
4 Free
brn/wht
wht/gry
5 Free
gry/wht
red/blu
6 Free
blu/red
red/ora
7 Free
ora/red
red/grn
2 8 Free
grn/red
red/brn 11 17a 17a 4
9 Port 17
brn/red 31 17b 17b 5
red/gry 02 18a 18a 4
10 Port 18
gry/red 22 18b 18b 5
blk/blu 13 19a 19a 4
11 Port 19
blu/blk 33 19b 19b 5
blk/ora 04 20a 20a 4
12 Port 20 Not
ora/blk 24 20b 20b 5 used
blk/grn 15 21a 21a 4 in
3 13 Port 21 SLMO8
grn/blk 35 21b 21b 5
blk/brn 06 22a 22a 4
14 Port 22
brn/blk 26 22b 22b 5
blk/gry 17 23a 23a 4
15 Port 23
gry/blk 37 23b 23b 5
yel/blu 08 24a 24a 4
4 16 Port 24
blu/yel 28 24b 24b 5
P31003-H3560-S100-3-7620, 03/06
3-206 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The SLMO8 and SLMO24 (Subscriber Line Module Cost Optimized UP0/E) boards provide 8
and 24 connections for connecting optiset E and optiPoint 500 telephones to HiPath 3750, Hi-
Path 3550 and HiPath 3700.
Lockout switch S1
(position = free,
factory default)
H1 (green)
LEDs
H2 (red)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-207
boards.fm
Table 3-92 SLMO8 (Not for U.S.) and SLMO24 - LED Statuses
P31003-H3560-S100-3-7620, 03/06
3-208 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-93 SLMO8 (Not for U.S.), SLMO24 - Cable 1 Assignment (SU Xx8)
SU Patch
Color a-Wire b-Wire connector SLMO8, MDFU/
Pair panel, Notes
group (Tip) (Ring) SLMO24 MDFU-E
BP: Xx8 MW8 pin
wht/blu 19 1a 1a 4
1 Access 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Access 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Access 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Access 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Access 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Access 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Access 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Access 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 Access 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 Access 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 Access 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 Access 12 Not
ora/blk 24 12b 12b 5 used
blk/grn 15 13a 13a 4 in
3 13 Access 13 SLMO8
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 Access 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 Access 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 Access 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-209
boards.fm
Table 3-94 SLMO8 (Not for U.S.), SLMO24 - Cable 2 Assignment (SU Xx9)
SU Patch
Color a-Wire b-Wire connector SLMO8, MDFU/
Pair panel, Notes
group (Tip) (Ring) SLMO24 MDFU-E
BP: Xx9 MW8 pin
wht/blu
1 Free
blu/wht
wht/ora
2 Free
ora/wht
wht/grn
1 3 Free
grn/wht
wht/brn
4 Free
brn/wht
wht/gry
5 Free
gry/wht
red/blu
6 Free
blu/red
red/ora
7 Free
ora/red
red/grn
2 8 Free
grn/red
red/brn 11 17a 17a 4
9 Access 17
brn/red 31 17b 17b 5
red/gry 02 18a 18a 4
10 Access 18
gry/red 22 18b 18b 5
blk/blu 13 19a 19a 4
11 Access 19
blu/blk 33 19b 19b 5
blk/ora 04 20a 20a 4
12 Access 20 Not
ora/blk 24 20b 20b 5 used
blk/grn 15 21a 21a 4 in
3 13 Access 21 SLMO8
grn/blk 35 21b 21b 5
blk/brn 06 22a 22a 4
14 Access 22
brn/blk 26 22b 22b 5
blk/gry 17 23a 23a 4
15 Access 23
gry/blk 37 23b 23b 5
yel/blu 08 24a 24a 4
4 16 Access 24
blu/yel 28 24b 24b 5
P31003-H3560-S100-3-7620, 03/06
3-210 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-95 SLMO24 - Assignment (SU Xx8, Xx9) (For U.S. Only)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-211
boards.fm
Table 3-95 SLMO24 - Assignment (SU Xx8, Xx9) (For U.S. Only)
P31003-H3560-S100-3-7620, 03/06
3-212 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.18 SLU8
Introduction
The SLU8 board for HiPath 3550 and HiPath 3350 (wall housing) with 8 digital subscriber line
interfaces allows up to 16 digital telephones to be connected in host-client operation (master-
slave operation).
Interfaces
50
1
X2 To
UP0/E ports
1-4 8
CUP/
SLU8 X1 CUC
1
UP0/E ports X3
5-8
8 2
Caution
7 After deactivating the power supply, you must wait a short while before plugging the
SLU8 in or out. If you do not wait before doing so, the CBCC/CBCP may be dam-
aged.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-213
boards.fm
3.3.19 SLU8R
Introduction
The SLU8R (Subscriber Line UP0/E Rack) boards provide eight ports for connecting optiset E
and optiPoint 500 telephones to HiPath 3500 and HiPath 3300 (19-inch housing).
Interfaces
UP0/E1 11 50
UP0/E ports X1
1–8 To
X2 CUPR
(8-pin MW8
jacks) CUCR
2
UP0/E8 88
MW8 X2, pin UP0/E ports MW8 X2, pin UP0/E ports
jack 1-4 jack 5-8
1 14 a1 5 54 a5
15 b1 55 b5
2 24 a2 6 64 a6
25 b2 65 b6
3 34 a3 7 74 a7
35 b3 75 b7
4 44 a4 8 84 a8
45 b4 85 b8
P31003-H3560-S100-3-7620, 03/06
3-214 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The STLS4 board for HiPath 3550 and HiPath 3350 (wall housing) has four S0 ports that can
operate as trunk interfaces or as subscriber line interfaces (see Page 3-217).
The STLS2 is an underequipped variant with two S0 ports.
Interfaces
The board does not supply terminals with power. Power must be supplied locally us-
> ing a local plug-in power supply or a bus power supply unit, for example.
50
To
S0 ports 1 CUP
Mini-Western STLS2/STLS4
X1 CUC
2
X2
Not in 3
STLS2
4
2
654321
2 = SX +
3 = SR +
4 = SR -
5 = SX -
SX = Signal transmit
SR = signal receive
Figure 3-84 STLS2 (Not for U.S.), STLS4 Interfaces (S30817-Q924-B313, -A313)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-215
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-216 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-217
boards.fm
8 7 6 5 4 3 2 1 6 5 4 3 2 1
SR SX SX SR SR SX SX SR
SR SX SX SR
P31003-H3560-S100-3-7620, 03/06
3-218 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
System Mini-Western
S01 to S04 through-jack
(MW8 = 8-pin)
SR.1 Receive 5
SX SR SR SX SX.1 Transmit 3 twisted
To switch from external to inter- SX.2 Transmit 6 pair
nal S0 operation, you must 8 7 6 5 4 3 2 1 SR.2 Receive 4
cross the SR and SX wires be-
* * = Not crossed in TA-S0
fore the first jack.
Maximum ranges:
System 1 2 3 8
Figure 3-86 Wiring and Ranges for S0 Bus Jacks (Not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-219
boards.fm
Connecting ISDN Terminals to HiPath 3550 and HiPath 3350 (for U.S. only)
● S0 Bus With MW8 jack, connecting S01 to S04:
– Connect the provided, silver-satin connector cord to each port on the STLS4 Module.
Connect the other end to a mounted MW jack, reversing the transmit and receive wires
as shown in Figure 3-88.
– Contact is always established using the center pins of MW jacks. Figure 3-87 shows
the pin assignments for jacks of different sizes.
– The ISDN terminals must have their own local power supply.
– Plug the ISDN terminal (connecting cord) into the MW jack. Connecting an ISDN S0
telephone requires a local power supply (e.g. manufactured by Sedlbauer).
● Pin Assignment of MW Jacks
8 7 6 5 4 3 2 1 6 5 4 3 2 1
SR SX SX SR SR SX SX SR
P31003-H3560-S100-3-7620, 03/06
3-220 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
S 0 Bus wiring from STLS4 port or optiset E ISDN adapter (for U.S. only)
SX SR SR SX ↵←→
↑↓
6 5 4 3 2 1
SX SR SR SX
6 5 4 3 2 1
Surface-mounted MW8 jack
8 7 6 5 4 3 2 1
(8-pin)
Cross the transmit and receive
wires from the STLS port (not
required in S0 bus from ISDN
8 7 6 5 4 3 2 1 adapter).
Device jack 1
(8-pin MW8)
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
Device jacks 1 to 7 ’
(8-pin MW8)
Device jack 2
(8-pin MW8)
Figure 3-88 S0 Bus Wiring from STLS4 Port or optiset E ISDN Adapter (For U.S. Only)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-221
boards.fm
3.3.21 STLS4R
Introduction
The STLS4R (Subscriber And Trunk Line S0 RACK) board provides four S0 basic rate access-
es for HiPath 3500 and HiPath 3300 (19-inch housing). These are operated either as external
trunk interfaces in TE (terminal equipment) mode or as internal S0 buses (PMP bus) in NT (net-
work terminator) mode with cross-connected RX-TX lines.
The board does not supply terminals with power; In this case, power must be sup-
> plied locally using a local plug-in power supply or a bus power supply unit, for exam-
ple.
Interfaces
S0 port 1 11 50
4 S0 ports
(MW8
(RJ45) X2 STLS4R
X1
jacks) To
S0 port 4
CUPR
48
CUCR
8 ... 1
3 = SX +
4 = SR +
5 = SR –
6 = SX –
SX = Signal transmit
SR = signal receive
P31003-H3560-S100-3-7620, 03/06
3-222 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Refer to Page 3-217 for information on connecting ISDN lines and telephones.
>
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-223
boards.fm
Introduction
The following boards provide S0 basic connections:
● STLSX4 (Subscriber Trunk Line S0 with ISAC-SX) S30810-Q2944-X = four S0 basic rate
accesses for use in HiPath 3550 and HiPath 3350.
● STLSX2 S30810-Q2944-X100 = two S0 basic rate accesses for use in HiPath 3550 and
HiPath 3350.
● STLSX4R (Subscriber Trunk Line S0 with ISAC-SX Rack) S30810-K2944-Z = four S0 basic
rate accesses for use in HiPath 3500 and HiPath 3300.
These are operated either as external trunk interfaces in TE (terminal equipment) mode or as
internal S0 buses (PMP bus) in NT (network terminator) mode with cross-connected RX-TX
lines.
Interfaces
The board does not supply terminals with power. Power must be supplied locally for
> telephones, for example, via a plug-in power supply unit.
P31003-H3560-S100-3-7620, 03/06
3-224 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
S0 port 1 11 50 CUP/CUC
(for STLSX2/
4 S0 ports
STLSX4)
(MW8 (RJ45)- X2
jacks) X1
S0 port 4 48 CUPR/CUCR
(for STLSX4R)
S0 ports 3 and 4 are 2
not assigned in
STLSX2.
8 ... 1
MW8 (RJ45) jack assignment:
3 = Transmit +
4 = Receive +
5 = Receive –
6 = Transmit –
S0 interface assignment
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-225
boards.fm
Configuring S0 interfaces
Depending on how the interfaces are applied, use HiPath 3000 Manager E to define the rele-
vant protocols for the trunks to be connected. Please note the additional information contained
in the protocol templates when selecting a suitable S0 protocol:
● CO = Interfaces to the public CO
● Bus = Interfaces to an internal station
● Master = Interfaces for a master system network
● Slave = Interfaces for a slave system network
● H150/H118 or H300 = Defines the CorNet protocol:
– H150/H118 = Optimized for interconnection with HiPath 3000
This option should also be selected in connection with HiPath ProCenter Office HPCO.
– H300 = Optimized for interconnection with HiPath 4000
● Direct or fixed connection: defines the type of connection for a network and controls the
supply of clock pulses:
– Direct = Communication systems are connected to one another by means of a direct
cable connection. The master system supplies the reference clock pulse for the net-
worked system.
– Fixed connection = Communication systems are connected over lines leased from a
network provider (with clock pulse supply). The master system receives the reference
clock pulse from the network.
A slave system always receives the clock pulse from the master system regardless of
whether the connection is direct or fixed.
Use the S0 interface S0 1 for connection to the public telecommunications network. You can
also connect S0 interfaces S0 2 to S0 4 to the ISDN trunk or to ISDN terminals (ISDN telephone,
group 4 fax device, PC, dialing aid) via an S0 bus.
P31003-H3560-S100-3-7620, 03/06
3-226 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
8 7 6 5 4 3 2 1 6 5 4 3 2 1
SR SX SX SR SR SX SX SR
SR SX SX SR
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-227
boards.fm
System Mini-Western
S01 to S04 through-jack
(MW8 = 8-pin)
SR.1 Receive 5
SX SR SR SX SX.1 Transmit 3 twisted
To switch from external to inter- SX.2 Transmit 6 pair
nal S0 operation, you must 8 7 6 5 4 3 2 1 SR.2 Receive 4
cross the SR and SX wires be-
* * = Not crossed in TA-S0
fore the first jack.
Maximum ranges:
System 1 2 3 8
P31003-H3560-S100-3-7620, 03/06
3-228 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.23 STMD3
Introduction
The STMD3 board (Subscriber and Trunk Module Digital S0) provides eight S0 basic rate ac-
cesses for HiPath 3800.
The range of the short S0 bus (up to eight Terminal Equipment Identifiers (TEI)) is
> limited to approximately 60 m.
If longer cables are required, the S0 bus type must be set to “Long” in HiPath 3000
Manager E developer mode. This provides a range of approximately 160 m. This set-
ting can be made in V5.0 SMR-05 (5. CV) or later.
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-229
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-230 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-231
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-232 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-104 STMD3 - Connector Panel Assignment with CHAMP Jack (For U.S. Only)
CHAMP jack STMD3 Notes
1 S0, Receive
26 S0, Receive Basic
2 S0, Transmit rate access 1
27 S0, Transmit
3 S0, Receive
28 S0, Receive Basic
4 S0, Transmit rate access 2
29 S0, Transmit
5 S0, Receive
30 S0, Receive Basic
6 S0, Transmit rate access 3
31 S0, Transmit
7 S0, Receive
32 S0, Receive Basic
8 S0, Transmit rate access 4
33 S0, Transmit
9 S0, Receive
34 S0, Receive Basic
10 S0, Transmit rate access 5
35 S0, Transmit
11 S0, Receive
36 S0, Receive Basic
12 S0, Transmit rate access 6
37 S0, Transmit
13 S0, Receive
38 S0, Receive Basic
14 S0, Transmit rate access 7
39 S0, Transmit
15 S0, Receive
40 S0, Receive Basic
16 S0, Transmit rate access 8
41 S0, Transmit
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-233
boards.fm
Table 3-105 STMD3 - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable
for Ports 1 - 16)
S0 patch panel,
Color a-Wire b-Wire SU MW8 pin
Pair STMD3 MDFU-E
group (Tip) (Ring) connector Station Trunk
connection connection
wht/blu 19 1Ea 1a 3 4
1 Basic
blu/wht 39 1Eb 1b 6 5
rate access
wht/ora 38 1Sa 1 2a 4 3
2
ora/wht 48 1Sb 2b 5 6
wht/grn 27 2Ea 3a 3 4
1 3 Basic
grn/wht 47 2Eb 3b 6 5
rate access
wht/brn 16 2Sa 2 4a 4 3
4
brn/wht 46 2Sb 4b 5 6
wht/gry 05 3Ea 5a 3 4
5 Basic
gry/wht 45 3Eb 5b 6 5
rate access
red/blu 14 3Sa 3 6a 4 3
6
blu/red 44 3Sb 6b 5 6
red/ora 23 4Ea 7a 3 4
7 Basic
ora/red 43 4Eb 7b 6 5
rate access
red/grn 32 4Sa 4 8a 4 3
2 8
grn/red 42 4Sb 8b 5 6
red/brn 11 5Ea 9a 3 4
9 Basic
brn/red 31 5Eb 9b 6 5
rate access
red/gry 02 5Sa 5 10a 4 3
10
gry/red 22 5Sb 10b 5 6
blk/blu 13 6Ea 11a 3 4
11 Basic
blu/blk 33 6Eb 11b 6 5
rate access
blk/ora 04 6Sa 6 12a 4 3
12
ora/blk 24 6Sb 12b 5 6
blk/grn 15 7Ea 13a 3 4
3 13 Basic
grn/blk 35 7Eb 13b 6 5
rate access
blk/brn 06 7Sa 7 14a 4 3
14
brn/blk 26 7Sb 14b 5 6
blk/gry 17 8Ea 15a 3 4
15 Basic
gry/blk 37 8Eb 15b 6 5
rate access
yel/blu 08 8Sa 8 16a 4 3
4 16
blu/yel 28 8Sb 16b 5 6
P31003-H3560-S100-3-7620, 03/06
3-234 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.24 STMD8
Introduction
The STMD8 (Subscriber And Trunk Module Digital S0) board contains eight S0 basic rate ac-
cesses for HiPath 3750 and HiPath 3700, which are used
● for the S0 trunk connection (via NT) (not for U.S.)
● for a Point-to-point or point-to-multipoint connection
● for S0 networking (not for U.S) (CorNet N, CorNet NQ or QSig)
● for an S0 bus for connecting ISDN telephones (not for U.S.) (separate power supply re-
quired).
LEDs H300
H301
.
.
.
.
H308
1 On
Lockout switch : S300
:
8
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-235
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-236 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 2-16 lists examples of the maximum cable lengths for connecting trunks.
>
HiPath 3750 Public network
NT (network termination):
The connection depends on the
country-specific NT.
1Sa
1Ea
1Eb
1Sb
MDFU, MDFU-E
S0 basic S0 basic
rate access 1 rate ac-
cess 2 ...... STMD8
When starting up S0 ports during operation with PABXs, it is important to ensure that
> the NT switch is in the POINT-TO-POINT position.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-237
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-238 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
For examples of the maximum cable lengths for direct CorNet N/CorNet NQ network-
> ing, please refer to Table 2-16.
Figure 3-97 S0 Networking Options (Not for U.S.) (Examples for HiPath 3750)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-239
boards.fm
HiPath 3750
The maximum permitted S0 bus
S0 bus length between the MDFU and the
STMD8 MDFU or last wall socket is 150 m (490 ft.).
MDFU-E
MDFU cable
(CABLU)
Max.10 m
ISDN terminal
Figure 3-98 S0 Bus to the STMD8 over the MDFU or MDFU-E (Not for U.S.)
8 7 6 5 4 3 2 1 6 5 4 3 2 1
SR SX SX SR SR SX SX SR
SR SX SX SR
P31003-H3560-S100-3-7620, 03/06
3-240 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
from MDFU/
patch panel
ISDN boards can also be connected to available optiPoint 500 series telephones (ex-
> cept for optiPoint 500 entry and optiPoint 500 economy) using an optiPoint ISDN
Adapter.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-241
boards.fm
Table 3-107 STMD8 - Cable and Connector Assignment (Not for U.S.)
SU S0 patch panel,
Color a-Wire b-Wire connector MDFU/ MW8 pin
Pair STMD8
group (Tip) (Ring) MDFU-E Station Trunk
BP: Xx8
connection connection
wht/blu 19 1Ea 1a 3 4
1 Basic
blu/wht 39 1Eb 1b 6 5
rate access
wht/ora 38 1Sa 1 2a 4 3
2
ora/wht 48 1Sb 2b 5 6
wht/grn 27 2Ea 3a 3 4
1 3 Basic
grn/wht 47 2Eb 3b 6 5
rate access
wht/brn 16 2Sa 2 4a 4 3
4
brn/wht 46 2Sb 4b 5 6
wht/gry 05 3Ea 5a 3 4
5 Basic
gry/wht 45 3Eb 5b 6 5
rate access
red/blu 14 3Sa 3 6a 4 3
6
blu/red 44 3Sb 6b 5 6
red/ora 23 4Ea 7a 3 4
7 Basic
ora/red 43 4Eb 7b 6 5
rate access
red/grn 32 4Sa 4 8a 4 3
2 8
grn/red 42 4Sb 8b 5 6
red/brn 11 5Ea 9a 3 4
9 Basic
brn/red 31 5Eb 9b 6 5
rate access
red/gry 02 5Sa 5 10a 4 3
10
gry/red 22 5Sb 10b 5 6
blk/blu 13 6Ea 11a 3 4
11 Basic
blu/blk 33 6Eb 11b 6 5
rate access
blk/ora 04 6Sa 6 12a 4 3
12
ora/blk 24 6Sb 12b 5 6
blk/grn 15 7Ea 13a 3 4
3 13 Basic
grn/blk 35 7Eb 13b 6 5
rate access
blk/brn 06 7Sa 7 14a 4 3
14
brn/blk 26 7Sb 14b 5 6
blk/gry 17 8Ea 15a 3 4
15 Basic
gry/blk 37 8Eb 15b 6 5
rate access
yel/blu 08 8Sa 8 16a 4 3
4 16
blu/yel 28 8Sb 16b 5 6
P31003-H3560-S100-3-7620, 03/06
3-242 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-243
boards.fm
Connecting ISDN terminals to HiPath 3750, HiPath 3700 (for U.S. only)
S0 bus wiring from STMD8 port on MDF or from optiset E ISDN adapter (for U.S. only)
1 1
1 2 2
optiset E ISDN SR 2 3 3
1
423
ABC
75
DEF
6
ABC
DEF
GHI
JKL
MNO
SX 3 4 4
adapter 8
09
GHI
MNO
PQRS
TUV
WXYZ
PQRS
TUV
SX 4 5 5
↵←→
↑↵
SR 5 6 6
6 7 7
MW8 jack 1 MW8 jack 2
8 8
(8-pin) (8-pin)
Contact is always estab-
lished using the center 100 Ω/0.25 W
pins Terminating
MW8 jacks 2 resistors in the last
MW8 = Cross the wires as shown to 7 (8-pin) jack
(not required in S0 bus from ISDN Last MW8 jack
adapter). MW8 jack 1
(8-pin) (8-pin)
1 1 1
2 2 2
STMD8 port on SX 2 3 3 3
MDF (port 1 shown) SX 27 4 4 4
SR 1 5 5 5
SR 26 6 6 6
. 7 7 7
. 8 8 8
.
Figure 3-101 STMD8 - S0 Bus Wiring from STMD8 Port or from ISDN Adapter (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
3-244 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.25 STMI2
Introduction
STMI2 (Subscriber Trunk Module IP) is a VoIP gateway board (VoIP - Voice over IP) which pro-
vides the functionality of HG 1500 in HiPath 3800. This includes:
● Connection of a local LAN to the HiPath 3800 and connection with external LANs via the
ISDN and DSL interfaces of HiPath 3800.
● Support for the conventional functions of an ISDN and DSL router with the additional func-
tionality of a media gateway for the transfer of voice, fax and data.
● Forwarding of calls between IP-supported networks (LAN, intranet, Internet) and circuit-
switched networks (ISDN, PSTN).
Configuration is performed via Web-based management (WBM) which enables the administra-
tion of HG 1500 without any special software requirements.
A combination of up to eight STMI2 boards can be used per system, but the following
> restrictions must be observed:
● A maximum of four STMI2 boards may be inserted per HiPath 3800 cabinet.
● To allow for future channel expansion with extension modules, the slot between
two STMI2 boards should remain free.
For information on configuration, refer to the HG 1500 Administration Manual.
For information on how to calculate the number of boards required for HG 1500, see
Section 2.6.8.
Board versions
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-245
boards.fm
Extension modules
The STMI2 board has two HGA (HiPath Gateway Accelerator) slots, which can be used to con-
nect the extension modules.
Table 3-110 STMI2 - Extension Modules
HGA
slot 1
HGA
slot 0
P31003-H3560-S100-3-7620, 03/06
3-246 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Connections
The STMI2 board features the following connections on the front panel:
● Two RJ45 jacks for LAN interfaces. These provide access to the Ethernet standard (IEEE
802.3) with 10 Mbps or 100 Mbps with automatic configuration. Manual configuration is
also possible.
● 9-pin Sub-D plug for V.24 interface
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-247
boards.fm
Front panel
P31003-H3560-S100-3-7620, 03/06
3-248 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
V.24interface
The V.24 cable (C30267-Z355-A25) is used for connecting the service PC.
The following settings must be chosen for a terminal or PC connected to the V.24 interface:
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-249
boards.fm
LAN interfaces
Pin Signal
1 TDP (Transmit Data +)
2 TDN (Transmit Data –)
3 RDP (Receive Data +)
4 TT1 (Transmit Termination 1)
5 TT2 (Transmit Termination 2)
6 RDN (Receive Data –)
7 RT1 (Receive Termination 1)
8 RT2 (Receive Termination 2)
Signals TT1/2 and RT1/2 are not needed for transmitting data. They represent a signal termi-
nation of 100 ohms (so-called Bob Smith termination) for the two unused wire pairs in a 4-pair
twisted pair cable.
P31003-H3560-S100-3-7620, 03/06
3-250 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The following cards - one per system - can be used for V5.0 SMR -10 and later to support coun-
try-specific CAS (Channel Associated Signaling) protocols:
● TCAS-2 (S30810-Q2945-X) in HiPath 3550
● TCASR-2 (S30810-K2945-X) in HiPath 3500
Please note that the cards listed can only be used in slots 7 and 9.
Each of the cards features two E1-CAS interfaces, which together support up to 60 B channels.
Since HiPath 3550 and HiPath 3500 each support a maximum of 30 B channels, a total of up
to 30 B channels can be used per card.
Direct connection to the MINI BNC connectors on each card is only possible for coaxial trunks
(75 ohms). An external impedance converter (F31505-E1-A146) must be used for symmetrical
trunks (120 ohms).
TCAS-2 and TCASR-2 function as converters, which convert the Euro-ISDN protocol on an
S2M link to the Channel Associated Signaling protocol CAS. In contrast to the predecessor TM-
CAS card, TCAS-2 and TCASR-2 communicate directly with the central control in the system.
All signaling and data traffic goes through TCAS-2 and TCASR-2. Unlike TMCAS, connection
to an S2M card is therefore not required.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-251
boards.fm
1 Modem (optional)
CAS interface 1: X910
X909
321
X805: Analog modem
X16
X21 X20
CAS interface 2: X911
X912 X17
Figure 3-105 TCAS-2, TCASR-2 (for selected countries only) – Interfaces and Jumpers
P31003-H3560-S100-3-7620, 03/06
3-252 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Settings
Table 3-113 TCAS-2, TCASR-2 (for selected countries only) – Jumper Functions
Table 3-114 TCAS-2, TCASR-2 (for selected countries only) – Jumper for Setting the V.24
Baud Rate
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-253
boards.fm
Connections
CAS interface 1:
CAS interface 2:
P31003-H3560-S100-3-7620, 03/06
3-254 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
RX TX RX TX
Seven-segment display
The card’s software status can be ascertained on the basis of the seven-segment display. For
this a distinction is made between the following boot phases:
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-255
boards.fm
Display Meaning
Initializing hardware
Downloading DSP (Digital Signal Processor) firmware
Downloading FPGA (Field Programmable Gate Array) firmware
Accessing flash EPROM (Save and Delete)
Error
Resetting card
Display Meaning
Linux kernel boot
P31003-H3560-S100-3-7620, 03/06
3-256 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-116 TCAS-2, TCASR-2 (for selected countries only) – Linux Operating System
States
Display Meaning
Mounting flash file system
Figure 3-108 TCAS-2, TCASR-2 (for selected countries only) – CAS Application Soft-
ware States
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-257
boards.fm
Modem (optional)
X21: Pin 1
Figure 3-109 TCAS-2, TCASR-2 (for selected countries only) – Optional Modem
The analog modem (modem kit F31505-E1-A147) is an optional submodule for the TCAS-2
and TCASR-2 cards, which is plugged into the X20 and X21 ports. This facilitates remote ad-
ministration of the CAS protocol converter on the TCAS-2 and TCASR-2 cards (see Page 3-
259).
P31003-H3560-S100-3-7620, 03/06
3-258 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Analog trunk
board
CAS CAS
Manager Manager
PSTN IP Network
Figure 3-110 TCAS-2, TCASR-2 (for selected countries only) – Connection Options for Card
Administration using CAS Manager
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-259
boards.fm
● HiPath 3500
TCASR-2: X805 Plug the RJ45 connector into
the free jack on an analog sub-
scriber line module.
● HiPath 3550
TCAS-2: X805 Disconnect the RJ45 cable and
connect the T/R wires to the
free terminals on an analog
subscriber line module.
Figure 3-111 TCAS-2, TCASR-2 (for selected countries only) – RJ45 Cable C39195-Z7208-
A10
P31003-H3560-S100-3-7620, 03/06
3-260 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Figure 3-112 TCAS-2, TCASR-2 (for selected countries only) – CAS Cable C39195-
A7700-B13
● Symmetrical trunk (120 ohms)
The impedance converter F31505-E1-A146 must be used for connecting to a symmetrical
trunk.
Figure 3-113 TCAS-2, TCASR-2 (for selected countries only) – Impedance Converter
F31505-E1-A146
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-261
boards.fm
3.3.27 TIEL
Introduction
The TIEL board (Tie Line Ear & Mouth) provides four bothway analog tie trunk circuits for E&M
signaling for HiPath 3750 and HiPath 3700. Each tie trunk circuit has eight connectors: incom-
ing speech path (2), outgoing speech path (2), incoming signaling (2) and outgoing signaling
(2).
This allows tie trunk traffic to other private communication systems.
Speech paths
The speech paths can be set to four-wire or two-wire mode. Four-wire connections should be
used for high transmission quality on analog networks (this description deals only with four-wire
mode).
The advantage of separate speech paths for the incoming and outgoing directions is that the
stability (echo) of a connection is not adversely affected. In addition, repeaters in the transmis-
sion equipment compensate for attenuation loss on the line.
P31003-H3560-S100-3-7620, 03/06
3-262 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-263
boards.fm
Interface specifications
Transmit path
Four-wire transmit level -3.5 dBr
Four-wire receive level -3.5 dBr
Characteristic impedance 600 ohms
Frequency range 0.3 to 3.4 kHz, +/- 1 dB
Dielectric strength of speech wires against 1 kV surge, 1.2/50 µs and 10/700 µs
ground
Signaling
Type of E&M interface (programmable) 1, 1A, 1B, 2, 3, 5
Protocols
To ANSI/EIA/TIA-464-A, configurable Immediate start
Wink signal
Delay signal
Signaling method DP or DTMF
P31003-H3560-S100-3-7620, 03/06
3-264 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
LEDs H0
H1
H2 1
H3 DIP-FIX switches
S102
(factory default):
Lockout switches: S1/1 23
(S1/1 to 4, :
S1/5 to 8 = used S1/8 1
1 4
for factory testing) 1 4
S104 S202
S103
2356 23
1 4 2356 1 4
S203 v S204
1
2356 2356
1 4
S302
1 4
23
S303 S304
1
2356 2356
1 4 1 4 S402
S403 S404 23
2356 2356
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-265
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-266 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
The following maximum ranges (without converter) must be taken into account:
> ●
●
4-wire speech: 8 km for 0.6 mm ∅
2-wire speech: 6 km for 0.6 mm ∅
Remote system/transmission
TIEL equipment with TIEL
1E 1E
- 48 V E E
1M 1M
- 48 V
1 4 1 1ka 1ga 1 4 1
1kb 1gb
1ga 1ka
2356 23 1gb 1kb 2356 23
CCT 1: S103 S102 CCT 1: S103 S102
(see Table 3-120)
CCT 2: S203 S202 CCT 2: S203 S202
CCT 3: S303 S302 CCT 3: S303 S302
CCT 4: S403 S402 CCT 4: S403 S402
System A System B
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-267
boards.fm
Remote system/transmission
TIEL equipment with TIEL
E M
- 48 V E E
M M
- 48 V
1 4 1 1 4 1
2356 23 2356 23
CCT 1: S103 S102 CCT 1: S103 S102
CCT 2: S203 S202 CCT 2: S203 S202
CCT 3: S303 S302 CCT 3: S303 S302
CCT 4: S403 S402 CCT 4: S403 S402
P31003-H3560-S100-3-7620, 03/06
3-268 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Remote system/transmission
TIEL equipment with TIEL
E E
- 48 V E E - 48 V
M M
1 4 1 1 4 1
2356 23 2356 23
CCT 1: S103 S102 CCT 1: S103 S102
CCT 2: S203 S202 CCT 2: S203 S202
CCT 3: S303 S302 CCT 3: S303 S302
CCT 4: S403 S402 CCT 4: S403 S402
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-269
boards.fm
Remote system//transmission-
TIEL equipment with TIEL
E E
- 48 V E E - 48 V
SG SG
M M
SB SB
1 4 1 1 4 1
2356 23 2356 23
CCT 1: S103 S102 CCT 1: S103 S102
CCT 2: S203 S202 CCT 2: S203 S202
CCT 3: S303 S302 CCT 3: S303 S302
CCT 4: S403 S402 CCT 4: S403 S402
P31003-H3560-S100-3-7620, 03/06
3-270 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
E&M interface type 2 - circuit diagram, MDFU or MDFU-E numbering (not for U.S.)
E 3a 7 a 11 a 15 a Incom-
150 120 ing
signal-
2.4 k SG 3b 7 b 11 b 15 b ing
1
S102
- 48 V
2 3
2 K101
1 M
4a 8 a 12 a 16 a Out-
3 S103 27
5 going
SB
4 4b 8 b 12 b 16 b signaling
6
PTC
- 48 V
Figure 3-119 E&M Interface Type 2 - Circuit Diagram, MDFU or MDFU-E Numbering (Not for
U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-271
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-272 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-273
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-274 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-275
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-276 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.28 TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (Not for U.S.)
Introduction
The MSI boards TLA2, TLA4 and TLA8 provide 2, 4 and 8 analog trunks (DP and DTMF dialing
method) for HiPath 3550 and HiPath 3350 (wall housing).
Interfaces
T/R ports 1
MSI 1 - 4 X2 50
TLA2/4
To CO 8
(CO 3, 4
1 To
not for X3 (free)
TLA2) X1 CUP/
8 CUC
1
to GEE X4 2
Module 10
Figure 3-120 TLA2, TLA4 (Not for U.S.) - Interfaces (S30817-Q923-Bxxx, -Axxx)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-277
boards.fm
The MSI board TLA8 with eight analog trunks for DP and DTMF signalling in HiPath 3550 and
HiPath 3350.
1
to GEE X3
Module
10
50
1
T/R ports
MSI 1 - 4 X2 TLA8
To CO 8 To
X1
CUP/
1 CUC
T/R ports
MSI 5 - 8 X4
To CO 8 2
1
to GEE X5
Module
10
P31003-H3560-S100-3-7620, 03/06
3-278 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The TLA4R (Trunk Line Analog Rack) board provides four ports for the analog trunk connection
(DP and DTMF signaling methods) on HiPath 3500 and HiPath 3300 (19-inch housing). There
are also two ALUM power failure transfers.
The transmission and function-oriented characteristics of the TLA4R are completely identical
to those of the TLA boards that are used in HiPath 3550 and HiPath 3350. The only differences
are
● the two ALUMs which are only available on the TLA4R.
● the call metering receiving equipment interface, which is only on the TLA boards.
Interfaces
11 50
Trunk 1 18
: 21
:
: X1
Trunk 4 To
8 MW8 X5 CUPR
jacks
ALUM CUCR
2
1+2
88
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-279
boards.fm
3 34 a trunk 3
35 b trunk 3
4 44 a trunk 4
45 b trunk 4
MW8 Jack X5, pin ALUM 1 + 2
5 54 TB1 ALUM1: Stn card connection
55 TA1
6 64 TB2 ALUM2: Stn card connection
65 TA2
7 74 BE1 ALUM1: Analog telephone
75 AE1 connection
P31003-H3560-S100-3-7620, 03/06
3-280 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.30 TM2LP
Introduction
The TM2LP (Trunk Module Loop Procedure) board connects up to eight analog trunks to Hi-
Path 3800 using the loop-start protocol.
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-281
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-282 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-283
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-284 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-285
boards.fm
Table 3-128 TM2LP - Connector Panel Assignment with CHAMP Jack (For U.S. Only)
CHAMP jack TM2LP Notes
1 1a 1 Ring
Port 1
26 1b 1 TIP
2 2a 2 Ring
Port 2
27 2b 2 TIP
3 3a 3 Ring
Port 3
28 3b 3 TIP
4 4a 4 Ring
Port 4
29 4b 4 TIP
5 5a 5 Ring
Port 5
30 5b 5 TIP
6 6a 6 Ring
Port 6
31 6b 6 TIP
7 7a 7 Ring
Port 7
32 7b 7 TIP
8 8a 8 Ring
Port 8
33 8b 8 TIP
9
Free
34
10
Free
35
11
Free
36
12
Free
37
13
Free
38
14
Free
39
15
Free
40
16
Free
41
P31003-H3560-S100-3-7620, 03/06
3-286 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-129 TM2LP - Connector Panel Assignment with SIPAC 1 SU Connectors (Cable for
Ports 1 - 16)
Patch
Color a-Wire b-Wire SU
Pair TM2LP MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11
9 Free
brn/red 31
red/gry 02
10 Free
gry/red 22
blk/blu 13
11 Free
blu/blk 33
blk/ora 04
12 Free
ora/blk 24
blk/grn 15
3 13 Free
grn/blk 35
blk/brn 06
14 Free
brn/blk 26
blk/gry 17
15 Free
gry/blk 37
yel/blu 08
4 16 Free
blu/yel 28
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-287
boards.fm
Introduction
The TMAMF (Trunk Module Analog for MultiFrequency Code Signaling) board contains eight
trunks for analog direct inward dialing. The system supports MFC-R2 signaling (default setting),
MFC-R2 with caller ID, tone dialing, and dial pulsing. It is not possible to use DTMF and MFC-
R2 (with or without caller ID) simultaneously.
There are two versions of this board:
● S30810-Q2587-A200 for use in HiPath 3750 and HiPath 3700.
● S30810-Q2587-A400 for use in HiPath 3550.
LEDs
H0 (green) H100 (yellow)
:
:
:
:
H7
0 On
: Lockout switch S501
: (factory default)
7
P31003-H3560-S100-3-7620, 03/06
3-288 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
1 2 3 4 5 5 4 3 2 1
6 7 8 9 9 8 7 6
1 1
2 3
3 2
5 5
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-289
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-290 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-291
boards.fm
Introduction
The trunk module TMC16 (Trunk Module Central Office) connects up to 16 analog ground-start
or loop-start trunks with the HiPath 3800.
Front panel
Figure 3-126 TMC16 (for selected countries only) (S30810-Q2485-X) - Front Panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
3-292 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-293
boards.fm
Table 3-134 TMC16 (for selected countries only) - SIVAPAC Connector Assignment on the
Backplane
a-Wire b-Wire
Pair SIVAPAC connector TMC16 MDFU-E Notes
(Tip) (Ring)
wht/blu 1 1a 1a
1 Port 1
blu/wht 23 1b 1b
wht/ora 3 2a 2a
2 Port 2
ora/wht 4 2b 2b
wht/grn 5 3a 3a
3 Port 3
grn/wht 6 3b 3b
wht/brn 7 4a 4a
4 Port 4
brn/wht 8 4b 4b
wht/gry 9 5a 5a
5 Port 5
gry/wht 10 5b 5b
red/blu 11 6a 6a
6 Port 6
blu/red 12 6b 6b
red/ora 13 7a 7a
7 Port 7
ora/red 14 7b 7b
red/grn 15 8a 8a
8 Port 8
grn/red 16 8b 8b
red/brn 17 9a 9a
9 Port 9
brn/red 18 9b 9b
red/gry 19 10a 10a
10 Port 10
gry/red 20 10b 10b
blk/blu 24 11a 11a
11 Port 11
blu/blk 25 11b 11b
blk/ora 26 12a 12a
12 Port 12
ora/blk 27 12b 12b
blk/grn 29 13a 13a
13 Port 13
grn/blk 30 13b 13b
blk/brn 31 14a 14a
14 Port 14
brn/blk 32 14b 14b
blk/gry 34 15a 15a
15 Port 15
gry/blk 35 15b 15b
yel/blu 37 16a 16a
16 Port 16
blu/yel 38 16b 16b
P31003-H3560-S100-3-7620, 03/06
3-294 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-135 TMC16 (for selected countries only) - Connector Panel Assignment with
CHAMP Jack
CHAMP jack TMC16 Notes
1 1a 1 Ring
Port 1
26 1b 1 TIP
2 2a 2 Ring
Port 2
27 2b 2 TIP
3 3a 3 Ring
Port 3
28 3b 3 TIP
4 4a 4 Ring
Port 4
29 4b 4 TIP
5 5a 5 Ring
Port 5
30 5b 5 TIP
6 6a 6 Ring
Port 6
31 6b 6 TIP
7 7a 7 Ring
Port 7
32 7b 7 TIP
8 8a 8 Ring
Port 8
33 8b 8 TIP
9 9a 9 Ring
Port 9
34 9b 9 TIP
10 10a 10 Ring
Port 10
35 10b 10 TIP
11 11a 11 Ring
Port 11
36 11b 11 TIP
12 12a 12 Ring
Port 12
37 12b 12 TIP
13 13a 13 Ring
Port 13
38 13b 13 TIP
14 14a 14 Ring
Port 14
39 14b 14 TIP
15 15a 15 Ring
Port 15
40 15b 15 TIP
16 16a 16 Ring
Port 16
41 16b 16 TIP
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-295
boards.fm
Table 3-136 TMC16 (for selected countries only) - Connector Panel Assignment with
SIPAC 1 SU Connectors (Cable for Ports 1 - 16)
Patch
Color a-Wire b-Wire SU
Pair TMC16 MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11 9a 9a 4
9 Port 9
brn/red 31 9b 9b 5
red/gry 02 10a 10a 4
10 Port 10
gry/red 22 10b 10b 5
blk/blu 13 11a 11a 4
11 Port 11
blu/blk 33 11b 11b 5
blk/ora 04 12a 12a 4
12 Port 12
ora/blk 24 12b 12b 5
blk/grn 15 13a 13a 4
3 13 Port 13
grn/blk 35 13b 13b 5
blk/brn 06 14a 14a 4
14 Port 14
brn/blk 26 14b 14b 5
blk/gry 17 15a 15a 4
15 Port 15
gry/blk 37 15b 15b 5
yel/blu 08 16a 16a 4
4 16 Port 16
blu/yel 28 16b 16b 5
P31003-H3560-S100-3-7620, 03/06
3-296 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
For V1.0 and later, TMCAS (Trunk Module Channel Associated Signaling) boards can be used
in HiPath 3750, HiPath 3700, and HiPath 3550 to support the country-specific CAS protocol.
The board converts the Euro-ISDN protocol on an S2M link into the Channel Associated Sig-
naling (CAS) protocol. The board functions only in connection with a TMS2 (HiPath 3750, Hi-
Path 3700) or TS2 (HiPath 3550). There is no direct connection between the TMCAS board and
the system’s central control unit. The TMS2/TS2 handles all signaling and data traffic.
Display H1
Lockout switch
S1
(position = free, factory default)
Switch S4
1
Off
= default
Jumper
S2
3 2 1
S3
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-297
boards.fm
You can use the C39195-Z7267-C13 cable for the connection between jack X10 and the ser-
vice PC.
Switches Function
S4-5 Reserved
S4-6 Flash memory: only for laboratory purposes (the flash memory
is erased when switch is set to “On”).
S4-7 Reserved
S4-8 Battery: Select the “On” switch position to make the connection
to the processor’s real-time clock only after the protocol convert-
er has been configured.
P31003-H3560-S100-3-7620, 03/06
3-298 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-299
boards.fm
Seven-segment display H1
The board statuses listed in the following table are displayed on H1.
Table 3-137 TMCAS - Seven-Segment Display H1
Display Meaning
Waiting for the TMCAS software download
P31003-H3560-S100-3-7620, 03/06
3-300 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
T T
M M
S C
2 A
S
Figure 3-128 TMCAS in HiPath 3750 and HiPath 3700 - Backplane View of the “8-Slot” Basic
Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-301
boards.fm
TMCAS X8, X9
X2 TS2
PSU/
Connection Cable UPS
TMCAS
TS2-TMCAS:
C39195-A9700-
B511, length =
0.57 m
TS2 X8
X2 TMCAS cable:
X9
C39195-A9700-
B512/-B514, length
= 10 m
P31003-H3560-S100-3-7620, 03/06
3-302 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Assignments for the two TMCAS cables for HiPath 3750, HiPath 3700, and HiPath 3550
You can use one of the following two cables to connect the network terminator NT, multiplexer
MUX, or modem to the TMCAS board:
● symmetric line (120 ohms)
Table 3-140 Assignment of the TMCAS Cable C39195-A9700-B512
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-303
boards.fm
Step Activity
1. Disconnect system from power supply and open system.
2. Insert TMS2 (HiPath 3750 and HiPath 3700) or TS2 (HiPath 3550).
3. ● HiPath 3750 and HiPath 3700: Insert TMCAS next to the TMS2, on the left.
● HiPath 3550 (wall housing): Insert TMCAS in slot 10.
4. Plug in TMS2/TS2-TMCAS connection cable.
5. Connect the NT to the system using the TMCAS cable.
6. Close the system and connect it to the power supply.
7. After the system has booted, both boards are entered in the system’s database
(TMS2 or TS2 and TMCAS).
8. If necessary, configure with HiPath 3000 Manager E.
Possible problems:
● TMCAS not entered in HiPath 3000 Manager E
The TMCAS is displayed automatically after the generation/regeneration of the database
in a system with a correctly inserted and connected TMCAS-TMS2/TS2 combination.
● Missing electrical connection between TMS2/TS2 and TMCAS
No TMCAS entry in the database. If a correctly configured database (with TMCAS insert-
ed offline) is then loaded into the system using generation/regeneration, the TMCAS con-
figured in HiPath 3000 Manager E appears only in the SW configuration.
● Incompatible board configuration
There is a correctly inserted TMCAS-TMS2/TS2 combination in the system. If there is a
different board entered in HiPath 3000 Manager E immediately to the left of the TMS2 (Hi-
Path 3750 and HiPath 3700) or in the HiPath 3550’s large slot, the generation is rejected.
P31003-H3560-S100-3-7620, 03/06
3-304 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Installing the ECGM tool and configuring the CAS protocol converter
This section contains information on installing the ECGM tool on the service PC and for config-
uring the CAS protocol converter on the TMCAS board.
The ECGM tool supports the following actions:
● Extender, database and software download
● CAS protocol configuration
● Database programming
● Trace options
Procedure
Step Activity
1. Create directory c:\ecginst on the service PC.
2. Set up the connection to the download server (for information on this, contact your
local ITSC) and copy the following files into the directory c:\ecginst:
● e1v0xx.exe (for example, e140ah.exe)
● Ee1v0yy.exe (for example, Ee140am.exe)
● Ecgm_vzz.exe (for example Ecgm_4aa.exe)
Explanation of the variables:
● v = software version
● xx = country version of a file
● yy = file version for channels
● zz = file version for maintenance
3. Run .exe files. This will extract the following files, for example:
● Ecgm.cab (WinZip file)
● Setup.lst (LST file)
● Setup.exe (EXE file)
● 4brazil.iam (IAM file)
● Ecg_edb4.ein (EIN file)
● 4brazil.eam (EAM file)
● E140ah.sin (SIN file)
● E140ah.pnm (PNM file)
● X140pai.pnm (PNM file)
● X130aq.pnm (PNM file)
4. Execute Setup.exe file. This will create the directory ecgm and extract various
files.
5. Copy vbrazil.iyy (for example, 4brazil.iam) to the directory ecgm.
6. Run the file ecgm.exe.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-305
boards.fm
Step Activity
7. Make the following settings in the ECGM tool:
● File/Options menu: Select the service PC’s COM interface (for example:
COM1)
● File/Install Software menu: Select the file E1v0xx.pnm (for example,
E140ah.pnm from the directory ecginst.
● File/Install Edb menu: Select the file Ecg_edbv.ein (for example
Ecg_edb4.ein) from the directory ecginst.
● File/Update Site menu:
– Under ECG SOFTWARE, select loadware file E1v0xx.pnm.
– Under “ECG EDB”, select file vbrazil.iyy.
– Under “FILE NAME”, select file extension .db for logging TMCAS events.
– Enter the customer name under “ECG NAME”.
8. Close the ECGM tool and then restart (ecgm.exe).
9. Enter the COM interface under “COMM” and the customer name in the Set-
tings/ECG Name menu. All other windows are updated automatically.
10. Channel configuration
Define the channel parameters in the View/Database menu (reserve unused
channels with “Out of Service”.):
● Protocol
● Signaling method (incoming and outgoing)
● Clock master (always central office)
● Operator number (corresponds to the number of the attendant console of the
HiPath 3000)
11. Software download
If the seven-segment display H1 on the TMCAS displays “H”, it is necessary to
download the extender software (Download/Extender menu). Otherwise, con-
tinue with the next step.
12. Start the software/database download using the Download/Software and
Database menu. This procedure takes approximately 8 minutes.
The download is complete when the configured channels display the “Idle” status.
The seven-segment display H1 on the TMCAS shows “A” (= active).
P31003-H3560-S100-3-7620, 03/06
3-306 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The TMCAS-2 card (Trunk Module Channel Associated Signaling) can be used in HiPath 3800
for V5.0 SMR-10 and later to support country-specific CAS protocols.
The card features two E1-CAS interfaces, which together support up to 60 B channels.
Both coaxial trunks (75 ohms) and symmetrical trunks (120 ohms) can be connected to the 15-
pin sub-D jacks on the card.
TMCAS-2 functions as a converter, which converts the Euro-ISDN protocol on an S2M link to
the Channel Associated Signaling (CAS) protocol. In contrast to the predecessor PBXXX card,
TMCAS-2 communicates directly with the central control in the system. All signaling and data
traffic goes through TMCAS-2. Unlike PBXXX, a connection with an S2M card is therefore not
required.
Up to three TMCAS-2 cards can be used in a HiPath 3800.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-307
boards.fm
1 Modem (optional)
3
X999 X17
2
1
X910: CAS inter-
face 2 X25
123
Figure 3-131 TMCAS-2 (for selected countries only) – Interfaces and Jumpers
P31003-H3560-S100-3-7620, 03/06
3-308 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Settings
Table 3-143 TMCAS-2 (for selected countries only) – Jumper for Setting the V.24 Baud
Rate
V.24 baud rate Jumper
(Kbps) X11 X12 X14
9.6 Open Open Open
(default setting)
19.2 Open Open Closed
38.4 Closed Open Closed
57.6 Open Closed Closed
115.2 Closed Closed Closed
9.6 All other configurations
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-309
boards.fm
Front panel
Seven-segment display
P31003-H3560-S100-3-7620, 03/06
3-310 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Seven-segment display
The card’s software status can be ascertained on the basis of the seven-segment display. For
this a distinction is made between the following boot phases:
Display Meaning
Initializing hardware
Downloading DSP (Digital Signal Processor) firmware
Downloading FPGA (Field Programmable Gate Array) firmware
Accessing flash EPROM (Save and Delete)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-311
boards.fm
Table 3-144 TMCAS-2 (for selected countries only) – U-boot (firmware) States
Display Meaning
Downloading image file (Linux and CAS application)
Error
Resetting card
Display Meaning
Linux kernel boot
P31003-H3560-S100-3-7620, 03/06
3-312 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Figure 3-133 TMCAS-2 (for selected countries only) – CAS Application Software States
Modem (optional)
X21: Pin 1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-313
boards.fm
HiPath 3800
X803 CAS
Backplane: TMCAS-2 V.24 interface Manager
IP Network
CAS
Manager
PSTN
Main distributor frame / patch panel
Figure 3-135 TMCAS-2 (for selected countries only) – Connection Options for Card Admin-
istration using CAS Manager
P31003-H3560-S100-3-7620, 03/06
3-314 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-315
boards.fm
BNC connector
Figure 3-136 TMCAS-2 (for selected countries only) – CAS Cable C39195-A7700-B14
P31003-H3560-S100-3-7620, 03/06
3-316 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The TMDID board (Trunk Module Direct Inward Dialing) provides direct inward dialing from the
central office (CO) to HiPath 3800.
The board has eight trunk circuits that connect to analog trunks.
The circuits can be set up for immediate start or wink start.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connec-
> tors. Since the TMDID board has SIVAPAC connector strips, you will have to install
a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.
For information on upgrade procedures, please see Section 4.2.5.5.
Switches
● Switches for manual trunk selection. In this case, all trunks are filtered one after the other
until the LED of the desired trunk flashes.
● Lockout switch which can be used to manually block the selected trunk circuit.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-317
boards.fm
Front panel
● Trunk circuit 1
● Trunk circuit 2
● Trunk circuit 3
● Trunk circuit 4
● Trunk circuit 5
● Trunk circuit 6
● Trunk circuit 7
Switch
Lockout switch
P31003-H3560-S100-3-7620, 03/06
3-318 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-149 TMDID (for U.S. only) - SIVAPAC Connector Assignment on the Backplane
a-Wire b-Wire
Pair SIVAPAC connector TMDID MDFU-E Notes
(Tip) (Ring)
wht/blu 1 1a 1a
1 Port 1
blu/wht 23 1b 1b
wht/ora 3 2a 2a
2 Port 2
ora/wht 4 2b 2b
wht/grn 5 3a 3a
3 Port 3
grn/wht 6 3b 3b
wht/brn 7 4a 4a
4 Port 4
brn/wht 8 4b 4b
wht/gry 9 5a 5a
5 Port 5
gry/wht 10 5b 5b
red/blu 11 6a 6a
6 Port 6
blu/red 12 6b 6b
red/ora 13 7a 7a
7 Port 7
ora/red 14 7b 7b
red/grn 15 8a 8a
8 Port 8
grn/red 16 8b 8b
red/brn 17
9 Free
brn/red 18
red/gry 19
10 Free
gry/red 20
blk/blu 24
11 Free
blu/blk 25
blk/ora 26
12 Free
ora/blk 27
blk/grn 29
13 Free
grn/blk 30
blk/brn 31
14 Free
brn/blk 32
blk/gry 34
15 Free
gry/blk 35
yel/blu 37
16 Free
blu/yel 38
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-319
boards.fm
Table 3-150 TMDID (For U.S. Only) - Connector Panel Assignment with CHAMP Jack
CHAMP jack TMDID Notes
1 1a 1 Ring
Port 1
26 1b 1 TIP
2 2a 2 Ring
Port 2
27 2b 2 TIP
3 3a 3 Ring
Port 3
28 3b 3 TIP
4 4a 4 Ring
Port 4
29 4b 4 TIP
5 5a 5 Ring
Port 5
30 5b 5 TIP
6 6a 6 Ring
Port 6
31 6b 6 TIP
7 7a Ring
Port 7
32 7b 7 TIP
8 8a 8 Ring
Port 8
33 8b 8 TIP
9
Free
34
10
Free
35
11
Free
36
12
Free
37
13
Free
38
14
Free
39
15
Free
40
16
Free
41
P31003-H3560-S100-3-7620, 03/06
3-320 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Table 3-151 TMDID (for U.S. only) - Connector Panel Assignment with SIPAC 1 SU Con-
nectors (Cable for Ports 1 - 16)
Patch
Color a-Wire b-Wire SU
Pair TMDID MDFU-E panel, Notes
group (Tip) (Ring) connector
MW8 pin
wht/blu 19 1a 1a 4
1 Port 1
blu/wht 39 1b 1b 5
wht/ora 38 2a 2a 4
2 Port 2
ora/wht 48 2b 2b 5
wht/grn 27 3a 3a 4
1 3 Port 3
grn/wht 47 3b 3b 5
wht/brn 16 4a 4a 4
4 Port 4
brn/wht 46 4b 4b 5
wht/gry 05 5a 5a 4
5 Port 5
gry/wht 45 5b 5b 5
red/blu 14 6a 6a 4
6 Port 6
blu/red 44 6b 6b 5
red/ora 23 7a 7a 4
7 Port 7
ora/red 43 7b 7b 5
red/grn 32 8a 8a 4
2 8 Port 8
grn/red 42 8b 8b 5
red/brn 11
9 Free
brn/red 31
red/gry 02
10 Free
gry/red 22
blk/blu 13
11 Free
blu/blk 33
blk/ora 04
12 Free
ora/blk 24
blk/grn 15
3 13 Free
grn/blk 35
blk/brn 06
14 Free
brn/blk 26
blk/gry 17
15 Free
gry/blk 37
yel/blu 08
4 16 Free
blu/yel 28
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-321
boards.fm
Introduction
TMDID8 (Trunk Module Direct Inward Dialing) provides direct inward dialing from the central
office (CO) to HiPath 3750 and HiPath 3700.
The board has eight trunk circuits that connect to analog trunks.
The circuits can be set up for immediate start or wink start.
T4 T3 T2 T1
S2 S1
A Trunk 3 A Trunk 1
Trunk 4 Trunk 2
G G
T8 T7 T6 T5
S4 S3
A A
Trunk 7 Trunk 5
Trunk 8 Trunk 6
G G
P31003-H3560-S100-3-7620, 03/06
3-322 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Switches
Adjust switches S1 to S4 to compensate for trunk loop resistance.
Table 3-152 TMDID8 (for U.S. only) - Trunk Circuits and Recommended Switch Settings
Trunk cir- Loop < 1800 ohms: Loop > 1800 ohms:
cuit Open switch Close switch
1 S1A, S1B, S1C, S1D S1A, S1B, S1C, S1D
2 S1E, S1F, S1G, S1H S1E, S1F, S1G, S1H
3 S2A, S2B, S2C, S2D S2A, S2B, S2C, S2D
4 S2E, S2F, S2G, S2H S2E, S2F, S2G, S2H
5 S3A, S3B, S3C, S3D S3A, S3B, S3C, S3D
6 S3E, S3F, S3G, S3H S3E, S3F, S3G, S3H
7 S4A, S4B, S4C, S4D S4A, S4B, S4C, S4D
8 S4E, S4F, S4G, S4H S4E, S4F, S4G, S4H
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-323
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-324 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.37 TMEW2
Introduction
The TMEW2 board (Trunk Module for E&M World) provides four analog tie trunk circuits for
E&M signaling for HiPath 3800. Each tie trunk circuit has eight connectors: incoming speech
path (2), outgoing speech path (2), incoming signaling (2) and outgoing signaling (2). This al-
lows tie trunk traffic to other private communication systems.
The peripheral board slots on the HiPath 3800 are fitted with SIPAC 9 SU connec-
> tors. Since the TMEW2 board has SIVAPAC connector strips, you will have to install
a SIVAPAC-SIPAC board adapter in order to be able to use it in HiPath 3800.
For information on upgrade procedures, please see Section 4.2.5.5.
Speech paths
The speech paths can be set to four-wire or two-wire mode. Four-wire connections should be
used for high transmission quality on analog networks (this description deals only with four-wire
mode).
The advantage of separate speech paths for the incoming and outgoing directions is that the
stability (echo) of a connection is not adversely affected. In addition, repeaters in the transmis-
sion equipment compensate for attenuation loss on the line.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-325
boards.fm
Front panel
To ensure sufficient shielding, provide the board with a shielding panel. For informa-
> tion on mounting the shielding panel, see Section 4.2.5.3.
P31003-H3560-S100-3-7620, 03/06
3-326 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-327
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-328 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
A TMGL4 trunk module connects up to four analog ground-start or loop-start trunks to HiPath
3550 and HiPath 3350.
Ground start is the default.
Warning
7 You must disconnect the power and remove the slip-on connectors from the TMGL4
board before removing it from the system.
Do not connect the slip-on connectors to the TMGL4 board until the board is seated
in its slot and the system power is on.
Failure to follow these instructions may severely damage the system.
Interfaces
50
1 To
To trunks X2 TMGL4 board X1 CUP/
8 CUC
2
To ANI4 X3
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-329
boards.fm
Contact assignment
P31003-H3560-S100-3-7620, 03/06
3-330 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
A TMGL4R trunk module connects up to four analog ground-start or loop-start trunks to HiPath
3500 and HiPath 3300.
Ground start is the default.
Interfaces
1
To ANI4R X5 (MW10 jack) 50
11
To trunk 1
X1
: To
: X4 (4 MW4 jacks) CUPR
: CUCR
To trunk 4 2
44
To GEE X3
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-331
boards.fm
Contact assignment
P31003-H3560-S100-3-7620, 03/06
3-332 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The TMGL8 trunk module connects up to eight analog ground-start or loop-start trunks to Hi-
Path 3750 and HiPath 3700.
Ground start is the default.
Switches 1
On
LEDs H1
.
.
.
.
H8
Switches
The TMGL8 board has an eight-path microswitch under a flip-up cover. The following settings
apply for each channel:
● ON (right): Channel is enabled.
● OFF (left): Channel is disabled; no new seizures are permitted.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-333
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-334 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
A TML8W (Trunk Module Loop Start World) board connects up to eight analog trunks for Hi-
Path 3750 and HiPath 3700 using the loop-start protocol.
The jumpers on the TML8W must be adjusted for call detail recording with a GEE8 subboard.
Jumpers on TML8W
W300
For Austria only: If a ÜFS trunk is connected to the TML8W, remove the jumpers
> (W300 to W650) to activate silent reversal.
If silent reversal is inactive, users in the HiPath 3750 and HiPath 3700 would hear a
busy signal following backward release instead of being released.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-335
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-336 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-337
boards.fm
Introduction
An TMQ4 (ISDN BRI) trunk module connects up to four digital trunks to the HiPath 3550 and
HiPath 3350.
The TMQ4 board provides basic rate interface (BRI) ISDN via a U2B1Q interface. The interface
supports the following central office protocols:
● AT&T 5Ess NI-1
● AT&T 5ESS Custom
● Nortel DMS100 NI-1
● Siemens EWSD NI-1
Interfaces
50
1
To
To trunks X2 TMQ4 board CUP/
X1
8 CUC
P31003-H3560-S100-3-7620, 03/06
3-338 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Contact assignment
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-339
boards.fm
Introduction
The TMST1 trunk board connects a digital trunk with HiPath 3750 and HiPath 3700. This is how
an ISDN primary multiplex connection is implemented (PRI, Primary Rate Interface) by means
of a T1 interface.
It can also be used for the following layer-1 operating modes:
● Super Frame SF
● Extended Super Frame ESF
A maximum of eight TMST1 modules can be used in a HiPath 3750 or HiPath 3700.
Rather than connecting to a main distribution frame (MDF), the TMST1 board connects to a
channel service unit (CSU). The CSU supplies the required secondary protection.
Lockout Up = in service
switch Down = out of service
LEDs H1
H2
P31003-H3560-S100-3-7620, 03/06
3-340 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-341
boards.fm
MW8 (RJ48C)
SIPAC 1
jack
SU jack
(to the CSU or
(Xx9 back-
networked
plane)
system)
Figure 3-146 TMST1 Adapter (SIPAC 1 SU - MW8 (RJ48C)) C39228-A7195-A12 (for U.S.
only)
P31003-H3560-S100-3-7620, 03/06
3-342 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Introduction
The TMS2 (Trunk Module S2M) board provides 30 B channels (voice channels) for HiPath 3750
and HiPath 3700, which are used
● for the S2M trunk connection (via NT).
● for the S2M networking via S2M lines.
To support country-specific CAS protocols, you can use the Euro-ISDN CAS gateway ECG.
The ECG cabinet is a protocol converter that converts the Euro-ISDN protocol into the Channel
Associated Signaling CAS protocol. Refer to the installation instructions, which are provided
with each ECG cabinet, for information on the connection and power supply.
For HiPath 3000 V1.0 and later, you can also use the new TMCAS board to support country-
specific CAS protocols.
LEDs H1 (red)
H2 (green)
H3 (red)
Lockout switch S1
(position = free, S1
factory default)
Jumper 1 X300
(setting = symm. 2
3
line (120 ohms,
factory default) X302 1 X301
2
3
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-343
boards.fm
Jumper settings
The X300 or X302 jumpers are used to set the TMS2 interface for the connection of this inter-
face to NT1. The following can be set:
● symmetric line (120 ohms)
Use only pre-formed cables S30267-Z57-Axxx to guarantee problem-free operation
(length = 6 m (not available in Germany), 10 m or 20 m).
● coaxial line (75 ohms)
S30267-Z69-Axxx.
Table 3-166 TMS2 (Not for U.S.) - SU Connector Assignment and Cable Color Codes
Note that the SU connector Xx9 was used in the old TMS2M board.
>
P31003-H3560-S100-3-7620, 03/06
3-344 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-345
boards.fm
Cable S30267-Z57-Axxx
TMS2 NT
6 m (not Germany), 10 m and 20 m
Caution
7 In order to guarantee successful operation, you must ensure that the NT is
grounded on the network provider side.
● Power supply
The NT must be fed over the –48 V (max. 10 W, observe the power requirements of the
NTs) of the UPSM (see Figure 3-149).
The voltage is fed out on backplane connector X06 (pins 17 + 37 = –48 V). Use the CABLU
supplied to connect the system with the MDFU. This places the voltage on pair no. 15 (= –
48 V) of the splitting strip.
The delivery does not include a CABLU if the REAL board has been ordered or is already
being used (the necessary CABLU is included in the delivery of the “ALUM using REAL”
feature).
P31003-H3560-S100-3-7620, 03/06
3-346 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
MDFU - 48 V
X06
0V UPSM
CABLU
- 48 V Pair no. 15
Earth
NT TMS2
HiPath 3750,
HiPath 3700
S2M - NT Connection
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-347
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-348 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
S2M networking
For examples of the maximum cable lengths for direct CorNet N/CorNet NQ networking, please
refer to Table 2-16.
TMS2 NT NT TMS2
Fixed connection
(cabling must be approved
by NT supplier)
Cable S30267-Z57-Axxx
6 m (not Germany), 10 m and 20 m
S2M networking using leased lines
HiPath 3000,
HiPath 3750, HiPath 3700 HiPath 4000
TMS2 NT NT TMS2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-349
boards.fm
Introduction
The digital T1/PRI trunk module (TST1) connects the communications server to primary rate
interface (PRI) ISDN via a T1 interface.
There are two versions of this board:
● S30810-Q2919-X - for use in the HiPath 3550 (wall housing)
● S30810-K2919-Z - for use in the HiPath 3500 (19-inch housing)
The board can also be used for the following layer-1 operating modes:
● Super Frame SF
● Extended Super Frame ESF
Board usage is subject to the following restrictions:
● Only one TST1 board allowed (primary multiplex access)
● For slot 7 or 9 only
Rather than connecting to a main distribution frame (MDF), the TST1 connects to a channel
service unit (CSU). The CSU supplies the required secondary protection.
Interfaces
50
To CO 1
To
X2 TST1 CUC
X1
8 CUCR
P31003-H3560-S100-3-7620, 03/06
3-350 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
Contact assignment
Contact X2 Contact X2
1 b-wire (ring), receive 5 a-wire (tip), transmit
2 a-wire (tip), receive 6 not connected
3 not connected 7 not connected
4 b-wire (ring), transmit 8 not connected
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-351
boards.fm
Introduction
The board contains a four-wire interface with S2M code for connection to the public telecommu-
nications network or private networks.
Up to thirty trunk calls can be conducted simultaneously via the S2M interface. The total trans-
mission speed including signaling and synchronization is 2048 Mbps.
Two trace files are available:
● Implemented up to and including V4.0:
– TS2 (Trunk Module S2M) S30810-Q2913-X100 (Figure 3-154) - for use in HiPath 3550
(wall housing)
– TS2R (Trunk Module S2M Rack) S30810-K2913-Z100 (Figure 3-155) - for use in Hi-
Path 3500 (19-inch housing)
● Implemented in V5.0 and later:
In HiPath 3000/5000 V5.0 and later, the B channels in the TS2 and TS2R boards
> are subject to license. Consequently, the two boards below have been assigned
a new hardware identification code. The new codes prevent the boards from be-
ing used in earlier versions. Functionality and layout of the boards have not been
changed.
– TS2 (Trunk Module S2M) S30810-Q2913-X300 (Figure 3-154) - for use in HiPath 3550
(wall housing)
– TS2R (Trunk Module S2M Rack) S30810-K2913-Z300 (Figure 3-155) - for use in Hi-
Path 3500 (19-inch housing)
Board usage is subject to the following restrictions:
● Only one TS2/TS2R board allowed (primary multiplex access)
● For slot 7 or 9 only
To support country-specific CAS protocols, you can use the Euro-ISDN CAS gateway ECG.
The ECG cabinet is a protocol converter that converts the Euro-ISDN protocol into the Channel
Associated Signaling CAS protocol. Refer to the installation instructions, which are provided
with each ECG cabinet, for information on the connection and power supply.
For HiPath 3000 V1.0 and later, you can also use the new TMCAS board to support country-
specific CAS protocols.
P31003-H3560-S100-3-7620, 03/06
3-352 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
TS2 interfaces
S2M interface:
1 TS2 50
● Wieland termi- X2
nal (symm. line)
8 To
X1 CUC
1
● MW8 (RJ48C)
jack (MW line) X5
2
TS2R interfaces
TS2R 50
To
S2M interface:
X1 CUCR
1
● MW8 (RJ48C)
X5
jack (MW line)
2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-353
boards.fm
Network interfaces
The TS2 board is connected to the network transfer point (NT1) via the symmetrical line (120
ohms, four-wire twisted-pair cable) at X2 or via an MW line at X5.
Note: use the connection kits listed on Page 3-356 for NT connections in Spain and Portugal.
● Symmetrical line (120 ohms)
The maximum cable length (approx. 130 m) depends on the quality of the cable used and
its signal attenuation. Use shielded cables only to guarantee proper operation.
Connect the cable to the X2 using an 8-pin Wieland terminal (TS2 only).
Table 3-169 Contact Assignments for X2 Connector
Contact X2 (TS2 only)
1 –48 V (NT1 feeding), max. 15 W
2 0 V (NT1 feeding)
3 GND
4 Board ID for TMCAS
5 a-wire (T), transmit
6 b-wire (R), transmit
7 a-wire (T), receive
8 b-wire (R), receive
● MW line (MW8 jack (RJ48C))
The shielded 8-pin MW8 (RJ48C) jack X5 is provided for connecting MW lines. The maxi-
mum cable length (approx. 100 m) depends on the quality of the cable used and its signal
attenuation.
Table 3-170 Contact Assignments for the MW8 (RJ48C) jack X5
Pin X5 Pin X5
1 b-wire (R), receive 6 Free
2 a-wire (T), receive 7 Free
3 Free 8 Free
4 b-wire (R), transmit 11 GND
5 a-wire (T), transmit 12 GND
An additional line must be provided from pins 1 and 2 on the X2 connector to NT1 for NT1
feeding.
P31003-H3560-S100-3-7620, 03/06
3-354 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
TS2/TS2R NT1
Caution
7 There should be absolutely no ground connection between the HiPath 3550 wall
housing and the NT. Do not connect the shield of the connection cable you are using
either on the HiPath 3550 side or on the NT side.
If the HiPath 3550 system is separately grounded (such as with the 19-inch housing
of the HiPath 3500), you may make a connection between HiPath 3550 and NT.
NT1 power supply
● TS2 board
The NT1 supply voltage of –48 V can be tapped from the X2 connector (see Table 3-169).
There is a power limit of < 15 W for this voltage, which the system feeds over the CUC.
● TS2R board
The NT1 power supply must come from an S30122-X7321-X (S30122-X7321-X100 with
UPS operation) power supply unit.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-355
boards.fm
Cable 1 Interface
TS2/TS2R converter Cable 2 NT
● Portugal
Public
HiPath 3550, HiPath 3500 network
Cable 1 Interface
TS2/TS2R converter Cable 2 Cable 3 NT
P31003-H3560-S100-3-7620, 03/06
3-356 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.47 4SLA (Not for U.S.), 8SLA, 16SLA (Not for U.S.)
Introduction
The 4SLA, 8SLA, and 16SLA (Subscriber Line Analog) modules for analog T/R interfaces con-
nect HiPath 3550 and HiPath 3350 (wall housing) to conventional analog telephones and sup-
plementary equipment (such as group 3 fax machines and entrance telephone adapters).
Interfaces
1 50
T/R ports
1-4 X2
Stns. 1 to 4 8 X1
1 To
4/8SLA
T/R ports CUP
5-8 X3 CUC
Stns. 5 to 8 8 2
(not with
4SLA)
Figure 3-158 4SLA (Not for U.S.), 8SLA - Interfaces (S30810-Q2923-X200, -X100)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-357
boards.fm
1
T/R ports X2
1-4 8 50
Stns. 1 to 4
1
T/R ports
5-8 X3
8 X1
Stns. 5 to 8 To
1 16SLA
CUP
T/R ports
X4 2 CUC
9-12
Stns. 9 to 12 8
1
T/R ports
13-16 X5
Stns. 13 to 16 8
Contact X2 X3 X4 X5
(T/R ports 1 to (T/R ports 5 to (T/R ports 9 to (T/R ports 13-
4) 8) 12) 16)
1 a1 a5 a9 a 13
2 b1 b5 b9 b 13
3 a2 a6 a1 a 14
4 b2 b6 b 10 b 14
5 a3 a7 a 11 a 15
6 b3 b7 b 11 b 15
7 a4 a8 a 12 a 16
8 b4 b8 b 12 b 16
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu settings: Set up station –> Sta-
tion –> Param –> Flags).
P31003-H3560-S100-3-7620, 03/06
3-358 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-359
boards.fm
3.3.48 8SLAR
Introduction
The 8SLAR (Subscriber Line Analog Rack) board provides eight T/R interfaces for connecting
analog telephones and supplementary equipment (such as group 3 fax machines and TFE
adapters) in HiPath 3500 and HiPath 3300 (19-inch housing).
Interfaces
Port 1 11 50
T/R ports X1
1–8 To
X2 CUPR
(4-pin MW8
jacks) CUCR
2
Port 8 88
MW8 jack X2, pin T/R ports 1-4 MW8 Jack X2, pin T/R ports 5-8
1 14 a1 5 54 a5
15 b1 55 b5
2 24 a2 6 64 a6
25 b2 65 b6
3 34 a3 7 74 a7
35 b3 75 b7
4 44 a4 8 84 a8
45 b4 85 b8
P31003-H3560-S100-3-7620, 03/06
3-360 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-361
boards.fm
3.4 Options
3.4.1 ALUM4
Introduction
In the event that HiPath 3550 or HiPath 3350 experience a voltage drop, voltage dip or unre-
coverable system errors, a trunk failure transfer (ALUM) is activated (MSI only).
The module implements a power failure transfer for four analog telephones. The only kind of
telephone that can be used is an analog telephone. The signaling method of the connected
telephones should be the same as that on the trunk line, otherwise signaling will not be possi-
ble.
When the system is deactivated or if an error occurs, the trunk lines are connected directly to
the telephones. When normal operation is resumed, the transfer represented in the figure be-
low takes place.
16 System 1
From analog trunks Pins 1-8
To analog trunk board
X3
To analog stations
To central control or
X4
analog station board
Pins 9-16
P31003-H3560-S100-3-7620, 03/06
3-362 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Interfaces
CB side
1
X1
from the CO X3 16 1
X6
8
1 ALUM module
to the X4
X2
8
Board side
The cable that is plugged in by default is split and is connected to the TLA and to the
> 4/8/16SLA board.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-363
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-364 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Trunk
Connector
X3 HiPath 3550
HiPath 3350
ALUM
R1 Relay T1
Connector X6
K1-B K2-B
BT1 (T1) Trunk
AT1 (R1) board
TA1 Station
TB1 board
K1-C K2-C
Connector
X4
Analog telephone
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-365
boards.fm
3.4.2 AMOM
Introduction
AMOM is an opto-electronic converter that can be used to connect fiber optic cables to the Sub-
D jacks on the front panel of the DIUN2 and DIU2U boards.
HiPath 3800
or
S
U
DIU2U B
D
AMOM variants
AMOM variant Wave length Op.fiber Cable length Cable attenua- Maximum at-
cable (km) tion tenuation1
(dB/km) (dB)
S30807-K5480- 850/820 nm 50 µm 2.5 3 11.5
X100 multimode 62.5 µm 3 3.5 14.5
S30807-K5480- 1300 nm 50 µm and 6 1 10
X200 multimode 62.5 µm
S30807-K5480- 1300 nm 9 µm/125 8 0.5 8
X300 mono mode
1 Maximum optical attenuation in an AMOM to AMOM connection: a reserve of 4 dB attenuation must be included for ageing
and splicing.
P31003-H3560-S100-3-7620, 03/06
3-366 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Connector assignment
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-367
boards.fm
Introduction
The ANI4 (Automatic Number Identification) board is responsible for receiving station numbers
modulated using the CPFSK method, demodulating them, and forwarding them to the base
system HiPath 3550 and HiPath 3350. In V4.0 SMR-7 or later, the station name is analyzed in
addition to the call number and shown on the telephone display.
Each ANI4 can serve four trunks. It contains the external trunk board hardware interfaces
(TMGL4) as well as a trunk and options bus interface. The trunks are transferred directly on the
board between the trunk and the trunk board interfaces.
LEDs CBside
2/1
4/3 (green) (red) X1
6/5 X 3 *)
TMGL4
8/7
10/9
ANI4
1
Trunk X4
X2
8
Board side
*) Pins: Component side/solder side
P31003-H3560-S100-3-7620, 03/06
3-368 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Table 3-177 ANI4 (for selected countries only) - LED Statuses for Trunk 1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-369
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-370 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Caution
7 Remove the trunk slip-on connectors from the TMGL4 board before starting to work
on the system.
Be sure to reinstall the ANI4 and TMGL4 boards in their slots before reconnecting
the trunks.
1. Disconnect the trunks from theTMGL4 board (Figure 3-166: Figure 1).
2. Unplug the system from the power supply.
3. Install the ANI4 board in the system.
4. Connect the OPAL adapter cable to the ANI4 board.
5. Use the ribbon cable supplied with the board to connect ANI4 and TMGL4, making sure
that the colored markings (pin 1) at both ends of the cable are facing upwards(Figure 3-
166: Figure 2).
6. Connect the trunk slip-on connectors to the ANI4 (Figure 3-166: Figure 3).
7. Restart the system by reconnecting the power plug.
Pin 1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-371
boards.fm
Introduction
The ANI4R (Automatic Number Identification Rack) board is responsible for receiving station
numbers modulated using the CPFSK method, demodulating them, and forwarding them to the
HiPath 3500 or HiPath 3300 base system. In V4.0 SMR-7 or later, the station name is analyzed
in addition to the call number and shown on the telephone display.
Each ANI4R module can serve four trunks. It contains the external trunk board hardware inter-
faces (TMGL4R) and the options bus interface.
Interfaces
X2
Board side
Figure 3-167 ANI4R (for selected countries only) (S30807-Q6917-Z103)
P31003-H3560-S100-3-7620, 03/06
3-372 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Contact assignment
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-373
boards.fm
Caution
7 Place the central control board on a flat surface before inserting a subboard. Other-
wise you may damage the board.
Introduction
The HiPath 3000 systems use different modules or boards for playing announcements and mu-
sic on hold. For details on connecting these boards, refer to the manufacturer’s installation in-
structions.
The following HiPath Xpressions Compact boards support music on hold in V4.0
> SMR-7 or later and announcements in V5.0 or later:
● IVML8, IVML24 (HiPath 3750, HiPath 3700)
● IVMNL, IVMN8 (HiPath 3800)
● IVMP8 (not for U.S.), IVMP8R (not for U.S) (HiPath 3350, HiPath 3300)
● IVMS8, IVMS8R (HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300)
For detailed information on HiPath Xpressions Compact, startup and administration,
see the manual for the product (see Section 1.6, “Information on the Intranet”: Elec-
tronic Documentation on Com ESY Products).
Overview
P31003-H3560-S100-3-7620, 03/06
3-374 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Cable duct
Slot for
EXM module
Figure 3-168 EXM Slot for HiPath 3550 and HiPath 3350 Wall Housing
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-375
boards.fm
Connection of EXMR
Front panel
of the system
X1
X2
EXMR
Cinch jack (component side)
Cable C39195-Z7001-C79
P31003-H3560-S100-3-7620, 03/06
3-376 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
3.4.6 EVM
Introduction
The optional subboard EVM (Entry Voice Mail) provides the functionality of integrated Voice
Mail in HiPath 3550, HiPath 3350,HiPath 3500 and HiPath 3300. The central control boards
S30810-Q2935-A301 (CBCC) and S30810-Q2935-Z301 (CBRC) must be used for this.
The board is plugged directly into the X32 connector on the central control boards CBCC (see
Figure 3-1) or CBRC (see Figure 3-2) using the connector strip X2.
Caution
7 The EVM subboard must not be plugged in or out when the system is energized.
Place the central control board on a flat surface before inserting the EVM subboard.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-170).
Otherwise you may damage the board.
HiPath Entry Voice Mail has capacity to store up to two hours of recorded messages. You can
create up to 24 standard mailboxes and up to four of these can be configured as Auto Attendant
mailboxes (attendant mailboxes with automatic call acceptance, greeting with routing options,
day and night mode, speed dialing).
Information on administering HiPath Entry Voice Mail for HiPath 3000 can be found in the Hi-
Path 3000 Manager E Help.
Caution
7 If using a different voicemail application (such as HiPath Xpressions Compact), the
EVM voice mail ports must be deactivated. To do this, set the ports to the “Standard”
station type and remove them from the active voicemail hunt group. Next set the
number of mailboxes for autoconfiguration to “0”. This prevents the user making ac-
cidental changes to Call Management.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-377
boards.fm
Interfaces
Spacing bolts
X2
26-pin socket strip
P31003-H3560-S100-3-7620, 03/06
3-378 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Introduction
The EXMNA (external music on hold) module provides a connection for external music on hold
in HiPath 3550 and HiPath 3350.
The EXMNA connects to the CBCC and CBCP board (connector X4) by means of a ribbon ca-
ble.
● Ribbon cable connected = External music
● Ribbon cable not connected = Internal music
Expert mode code 22 11 allows you to choose between music on, music off, ring tone, or music
on unscreened transfer. If the EXMNA module is connected, you must select Music on using
Assistant T or HiPath 3000 Manager E. The module is operational as soon as it is plugged in.
Interfaces
1
Ribbon cable to X1
CB
10 EXMNA
To external music
source X2
Cable duct
Figure 3-172 EXMNA (for U.S. only) - Slot for HiPath 3550 and HiPath 3350
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-379
boards.fm
Contact assignment
P31003-H3560-S100-3-7620, 03/06
3-380 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Introduction
The Call Metering Receiving Equipment GEE8 (12/16 kHz) can be plugged into the TML8W
board to record call charge pulses (HiPath 3750 and HiPath 3700).
Interfaces X10 and X11 connect to the board.
Switch on GEE8
On 1 8
X10 X11
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-381
boards.fm
3.4.9 GEE12 (nor for U.S.), GEE16 (not for U.S.), GEE50 (not for U.S.)
Introduction
Each of the modules listed below supports four call-metering receiving units for recording and
preprocessing call charge pulses in HiPath 3550 and HiPath 3350.
Table 3-182 GEE12/GEE16/GEE50 (Not for U.S.) Modules
Interfaces
CB side
1 10
1
X1
to the TLA X3
X5
10
1 GEE module
X4
To CO
LS X2
8
Board side
Figure 3-174 GEE12, GEE16, GEE50 (Not for U.S.) - Interfaces (S30817-Q951-Axxx)
P31003-H3560-S100-3-7620, 03/06
3-382 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Contact assignments
Table 3-183 GEE12, GEE16, GEE50 (Not for U.S.) - Contact Assignments
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-383
boards.fm
Introduction
The HOPE (Hicom Office PhoneMail Entry) board provides Hicom Office PhoneMail Entry
functions.
The HOPE board does not identify itself to the system and is therefore not visible in
> the HiPath 3000 Manager E card map. When expanding a system (such as HiPath
3350 or HiPath 3550), ensure that a free slot is available.
Interfaces
On/off switch
(Off—towards LED
On—towards slot)
PCMCIA slot
Card ejector
Board components
The following list describes the purpose of the components on the HOPE board:
● The LED status indicator signals the state of the Hicom Office PhoneMail system
● The software load/diagnostic button is for software loads (for example, loading a specific
language).
● The digital station connector connects the HOPE board to the corresponding digital ports,
using a modular cable
P31003-H3560-S100-3-7620, 03/06
3-384 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
● The on/off switch turns the Office PhoneMail system on and off
● The PCMCIA slot is for Office PhoneMail software cards (for example, voice cards).
● The card ejector ejects the software cards from the PMCIA slot
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-385
boards.fm
Introduction
The adapter cable for connecting the central board to the first optional board comes in two ver-
sions:
● OPAL (Options Adapter Cable Long) C39195-A7001-B130 (Figure 3-176 - for use in Hi-
Path 3550 and HiPath 3350 (wall housing).
● OPALR (Options Adapter Cable Long Rack) C39195-A7001-B142 (Figure 3-177) - for use
in HiPath 3500 and HiPath 3300 (19-inch housing).
OPAL interfaces
Ribbon cable
folded and secured
CBCC/CBCP interface
P31003-H3560-S100-3-7620, 03/06
3-386 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
OPALR interface
CBRC interface
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-387
boards.fm
Introduction
In the event of a power failure or system error in HiPath 3800 and HiPath 3750, up to
● 1 analog trunk with a PFT1 (Power Failure Transfer) board
● 4 analog trunks with a PFT4 board
can be transferred (ALUM) to designated analog telephones (Figure 3-178).
When using an analog telephone for outgoing calls, you may need to adapt its signaling method
to match the signaling method of the connected trunk.
TRUNK
PFT a b
R
E TMB Trunk circuit
L
A TMA
I
S SMA
Analog station board
SMB (optional)
SLA SLB
Analog telephone
P31003-H3560-S100-3-7620, 03/06
3-388 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
2 x PFT1
or
1 x PFT4
System side Line network
Figure 3-179 Installation Location of PFT1 and PFT4 (MDFU/MDFU-E) (Not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-389
boards.fm
X1 X2 PFT4 X1
TMA 10 1 TMA 1 TMA
TMB TMB TMB
A A A
B B B
SMA SMA SMA
SMB SMB SMB
SLA SLA SLA
SLB SLB SLB
- 48
PFT
1 10 10
TMA 10 1 TMA
PFT1
TMB TMB
A A
B B
SMA SMA
SMB SMB TMA, TMB = Trunk circuit
SLA SLA A, B = a, b (Telephone company)
SLB SLB SMA, SMB = SLA board
- 48 SLA, SLB = Analog telephone
PFT
1 10
X3 X4
P31003-H3560-S100-3-7620, 03/06
3-390 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
3.4.13 REAL
Functions
The tasks of the REAL (S30807-Q5913-X) board in HiPath 3750 and HiPath 3700 are divided
into two functional areas (see Figure 3-182):
● Relay (REAL)
Four individual, controllable relays (K1 to K4) are available for special connections. The re-
lays are energized by the CBCPR board via the REAL socket X05 connection cable. The
switch contacts for all relays are floating and protected by surge protectors.
In addition, a - 48-V line fused using a PTC resistor is routed to MDFU/MDFU-E and can
be used there for external applications (max. 80 mA).
- 48-V lines are provided at pins 17 and 37 (SU connector X06) for external applications
with higher power requirements. These lines have a load capacity of max. 15 W.
● Power Failure Transfer ALUM (REAL)
This function is provided by two relays (K5, K6) with two switch contacts each. In the event
of a power failure or a system restart or reload, an analog trunk is transferred from the sys-
tem to an analog telephone. The system monitors the line’s loop current to avoid discon-
necting any trunk calls in progress when the power is restored.
In normal mode, the relays are activated:
– The trunk is connected to the line trunk module.
– The subscriber line is connected to the subscriber line module.
In the event of a power failure or during a restart or reload (low potential of trunk failure
transfer signal from CBCPR), the relays are deactivated giving rise to the following situa-
tion:
– The signals to the line trunk module and subscriber line module are split and the trunk
is connected directly to the subscriber line.
If the power supply voltage returns after an interruption and a trunk call is in progress, ac-
tivation of the trunk failure transfer relay is prevented (by optocoupler).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-391
boards.fm
Relay specifications
Electrical characteristics of the relays are as follows:
● Operating voltage: 12 Vdc
● Trunk failure transfer power consumption: 40 mA at 12 V nominal voltage
● Power consumption per relay: 20 mA at 12 V nominal voltage
● Trunk failure transfer contact load: 60 mA at -60 V nominal voltage
● Maximum trunk failure transfer contact load with atmospheric influence: 8 A
● Contact load for relays K1 to K4: 1 A with 250 Vac
● Maximum current drain - 48 VF: 80 mA
X80 X70
UPSM 07
X05
REAL X06
with
connection
cable
P31003-H3560-S100-3-7620, 03/06
3-392 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-393
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-394 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
3.4.14 REALS
Introduction
The REALS (Relais and ALUM for SAPP) board is used in HiPath 3800 to provide the following
functions:
● Four individual, controllable relays are available for special connections, such as door
openers.
The switch contacts for all relays are floating and protected by surge protectors.
Electrical characteristics of the relays are as follows:
– Maximum current drain at – 48 V: 80 mA
– Operating voltage: + 5 V
– Contact current: max. 1.25 A
– Contact power: max. 30 W
● Trunk failure transfer (ALUM)
In the event of a power failure or a system restart or reload, an analog trunk is transferred
from the system to an analog telephone. If the power supply voltage returns after an inter-
ruption and a trunk call is in progress, activation of the trunk failure transfer relay is prevent-
ed by optocoupler.
– Default = HiPath 3800 is in normal mode:
PFTALa/b (trunk) is connected to PFTASa/b (trunk board).
PFTTLa/b (telephone) is connected to PFTTSa/b (subscriber line module).
– Error = HiPath 3800 does not have any power
PFTTLa/b (telephone) is connected to PFTALa/b (trunk).
ALUM relay electrical data:
– Operating voltage: + 5 V
– Contact current: max. 1.25 A
– Contact power: max. 30 W
All of the functions are controlled by the CBSAP board.
Two –48-V lines fused using a PTC resistor are available for external applications. Signals are
picked up via MDFU-E (Table 3-185: M48VF1 / 0V_F and M48VF2 / 0V_F). Each trunk has a
maximum load capacity of 300 mA.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-395
boards.fm
Removal tab
You can insert a screwdriver here to remove REALS from the shelf.
P31003-H3560-S100-3-7620, 03/06
3-396 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Slot
Insert the REALS board into the slot marked 3 in the lower part of the shelf in the basic cabinet
and apply pressure until you hear a click (see Figure 4-22).
The slots for the power supply units and for the REALS board must be covered with an outer
panel before the system is started up. The outer panel is fixed onto the shelf with screws (see
Figure 3-184).
Figure 3-184 REALS Slots in the Basic Cabinet (With Outer Panel Mounted)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-397
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-398 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-399
boards.fm
Introduction
This current-limiting board is for connecting loop start trunks in France (HiPath 3550 and HiPath
3350). It includes the current-limiting components and surge-protection elements required by
law.
No options bus lines are needed.
The slot X3 wiring is polarized.
The STBG4 channel is looped between TLA and the trunk.
CB side
1
TLA X3 X1
10 STBG4
MDF
1
X4
Trunk X2
8
Board side
Figure 3-185 STBG4 (For France Only) - Interfaces (S30817-Q934-A)
P31003-H3560-S100-3-7620, 03/06
3-400 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Introduction
This option comes in two versions:
● STRB (Control Relay Board) S30817-Q932-A (Figure 3-186) - for use in HiPath 3550 and
HiPath 3350 (wall housing)
● STRBR (Control Relay Board Rack) S30817-K932-Z (Figure 3-187) - for use in HiPath
3500 and HiPath 3300 (19-inch housing)
The STRB or STRBR has four double-pin, double-throw relays as shown in Figure 3-188).
Actuators and sensors for monitoring, alerting, controlling and regulating can be connected to
the control relay board. Actuators are relays that can be energized from any station by means
of a code (such as a door opener). Sensors (such as thermostats or motion detectors) can de-
tect a change of status in the connected equipment and activate a feature or dial a station num-
ber stored in the system.
The board has a total of four outputs (in the form of two floating switch contacts each) and four
control inputs in the form of optocouplers for externally activating an electrically isolated nor-
mally open (NO) contact.
Caution
7 CDB data is stored on the board. When replacing the board, be sure to store the
CDB data elsewhere. If a used board is used, old data may still be present on the
board.
Only factory technicians should use the “Reset options” procedure in expert mode
(code 29-3-3). Using the procedure during operation returns all options to their fac-
tory defaults, and they must be reset before they can accept data again from the cen-
tral board.
Example: You can route the +12-V signal for power failure alert to the control input of the opto-
coupler for connector X4 or X6. Route the signal through a normally open (NO) contact that is
electrically isolated from the external device, then program the alert type. For safety, the control
voltage for the optocoupler is electrically isolated from the system’s other partial voltages.
For the manual relay on/off function and door opener, you must enter the desired switching time
(expert mode code 26 2).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-401
boards.fm
STRB interfaces
CBCC/CBCP side
1
8 1 8 1 X1
X3
X5 X6
MDF 8
1 STRB
X4
X2
8
Board side
STRBR interfaces
CBRC side
11
:
18 X1
21
8-pin MW8 :
28 X3
jacks 31
: STRBR
38
41
: X2
48
Board side
Warning
7 The STRB or STRBR interface is an SELV (Safety Extra-Low Voltage Circuit) inter-
face, as defined by IEC 60950.
Do not connect any circuits whose voltages exceed the following limit values:
Maximum: 30 Vac (42 Vpeak) or 60 Vdc.
P31003-H3560-S100-3-7620, 03/06
3-402 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
STRB or STRBR
K1.21
K1.22
K1.23
Relay
K1.11
K1.12
K1.13
+12 V +12 VI
OPTKP1
Sensor
To system
Figure 3-188 STRB and STRBR Board Relay and Sensor Functions
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-403
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-404 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-405
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-406 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
Introduction
You can use the V24/1 board in HiPath 3550 and HiPath 3350. This provides a serial V.24 in-
terface for connecting PCs, printers or applications.
Interfaces
1 Component side
26
shown
X2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-407
boards.fm
Connector assignment
TxD RxD
RxD TxD
RTS CTS
CTS RTS
DSR DTR
DTR DSR
Vcc
GND 0V
Figure 3-191 V.24 (RS-232) Connector Assignment, HiPath 3550 and HiPath 3350
P31003-H3560-S100-3-7620, 03/06
3-408 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
boards.fm
Boards for HiPath 3000
Options
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 3-409
boards.fm
P31003-H3560-S100-3-7620, 03/06
3-410 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Overview
4.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Installing HiPath 3800, page 4-3
● Installation Prerequisites, page 4-3
● Installation Procedure, page 4-4
● Installing HiPath 3800 (Standalone), page 4-5
● Installing HiPath 3800 (19-Inch Cabinet), page 4-21
● Installing Boards (Configuration Notes), page 4-31
● Connecting the Cable to the Backplane, page 4-51
● Using an External Main Distribution Frame or External Patch Panel, page 4-66
● Loading the System Software and Installing Subboards on the CBSAP, page 4-81
● Connecting Workpoint Clients, page 4-82
● Making Trunk and Networking Connections, page 4-82
● Performing a Visual Inspection, page 4-83
Installing HiPath 3750, HiPath 3700, page 4-85
● Installation Prerequisites, page 4-85
● Installation Procedure, page 4-86
● Installing HiPath 3750, page 4-88
● Installing HiPath 3700 (19-Inch Cabinet), page 4-129
● Loading the System Software and Installing Subboards on the CBCPR, page 4-153
● Configuration notes, page 4-154
● Connecting Workpoint Clients, page 4-163
● Making trunk connections, page 4-163
● Performing a Visual Inspection, page 4-164
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, page 4-165
● Installation Prerequisites, page 4-165
● Installation Procedure, page 4-166
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-1
inst_h3.fm
Topic
● Installing HiPath 3550 and HiPath 3350, page 4-167
● Installing HiPath 3500 and HiPath 3300 (19-Inch Housing), page 4-188
P31003-H3560-S100-3-7620, 03/06
4-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Warning
7 Only authorized service personnel should install and start up the system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-3
inst_h3.fm
4. Grounding the System, page 4-15 Grounding the System, page 4-28
Checking the Grounding, page 4-20 Checking the Grounding, page 4-30
5. Installing Boards (Configuration Notes), page 4-31
6. Connecting the Cable to the Backplane, page 4-51
7. If required: use an external main distribution frame or external patch panel,
from Page 4-66:
● Main Distribution Frame MDFU-E
● Patch Panel S30807-K6143-X
● S0 Patch Panel C39104-Z7001-B3
8. Loading the System Software and Installing Subboards on the CBSAP, page 4-81
9. Connecting Workpoint Clients, page 4-82
10. Making Trunk and Networking Connections, page 4-82
11. Performing a Visual Inspection, page 4-83
P31003-H3560-S100-3-7620, 03/06
4-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Selecting a site
The customer usually has a preferred installation site in mind.
Make sure that the customer’s site meets the following guidelines:
● To guarantee sufficient system ventilation, allow a minimum of 50 mm clearance between
the base of the cabinet and the ground and between stacked cabinets.
● When cabinets are stacked, the basic cabinet must always be at the bottom of the stack.
● Allow a minimum clearance of 10 cm both at the rear and the front of the cabinets for main-
taining boards and for wiring.
● Do not expose the systems to direct sources of heat (for example sunlight and heaters).
● Do not expose the systems to extremely dusty environments.
● Avoid contact with chemicals.
● Take every precaution to prevent the formation of condensation on the system during op-
eration. Systems covered with condensation must be dried before being used.
● Observe the environmental conditions specified in Section 2.11.
For U.S. Only:
● Install secondary-protection equipment.
● Avoid standard carpeting, as it tends to produce electrostatic charges.
● Ensure the availability of a power source that meets the requirements described in
Section 4.2.3.1.1.
● Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The
National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical
equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment.
Information on the design of the HiPath 3800 can be found in Section 2.2.2.1.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-5
inst_h3.fm
WARNING
7 Never connect a HiPath 3800 system or a combination of HiPath 3800 systems di-
rectly to a wall socket. Use a UL-listed or CSA-certified surge protector for every two
cabinets.
P31003-H3560-S100-3-7620, 03/06
4-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-7
inst_h3.fm
Introduction
The cabinets are not supplied with pre-installed boards. For information on board installation,
please see Section 4.2.5, “Installing Boards (Configuration Notes)”.
If it has been agreed to provide connector panels for connecting peripherals, these are included
in the delivery. For information on the installation procedure, please see Section 4.2.5.4,
“Mounting Connector Panels (if required)”.
The front plastic cover (for board servicing) and the rear plastic cover (for cable servicing) are
not attached to the system cabinets. Both covers are supplied in separate packages.
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before starting the system
and before connecting up the peripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
4.2.3.3.1 Overview
System configurations
The following setup options are possible for system cabinets:
● Single cabinet
● Two cabinets (stacked)
● Two cabinets (side by side)
P31003-H3560-S100-3-7620, 03/06
4-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Caution
7 To guarantee sufficient ventilation for the system cabinet, allow a minimum clear-
ance of 50 mm between the base of the cabinet and the ground.
Procedure
Step Activity
1. Place the system cabinet in the installation site and make sure that it is level and
stable.
2. Check that the space between the base of the cabinet and the ground is at least
50 mm.
3. If necessary, set up the basic cabinet in the following way:
● Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
● Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
● Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
A
≥ 50 mm
B
Figure 4-1 HiPath 3800 - Setting Up the Basic Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-9
inst_h3.fm
Caution
7 To guarantee sufficient ventilation for the system cabinets, comply with the following
requirements:
● The basic cabinet must be set up as the bottom cabinet.
● Allow a minimum of 50 mm clearance between the base of the cabinet and the
floor, and between basic and expansion cabinets.
Procedure
Step Activity
1. Place the system cabinet in the installation site and make sure that it is level and
stable.
2. Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
3. If necessary, set up the basic cabinet in the following way:
● Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
● Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
● Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
4. Place the expansion cabinet on top of the basic cabinet.
The cabinet feet have indents. When placing the expansion cabinet on top of the
basic cabinet, ensure that these indents are sitting precisely on top of the screw
heads in the four corners of the basic cabinet (Figure 4-2).
5. Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
6. If necessary, set up the expansion cabinet as described in Step 3.
P31003-H3560-S100-3-7620, 03/06
4-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-11
inst_h3.fm
≥ 50 mm
≥ 50 mm
Figure 4-3 HiPath 3800 - Installing a Stacked Two-Cabinet System (Rear View)
P31003-H3560-S100-3-7620, 03/06
4-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Caution
7 To guarantee sufficient ventilation in the system cabinets, allow a minimum clear-
ance of 50 mm between the base of the cabinets and the ground.
Procedure
Step Activity
1. Place the system cabinet in the installation site and make sure that it is level and
stable.
2. Check that the space between the base of the basic cabinet and the ground is at
least 50 mm.
3. If necessary, set up the basic cabinet in the following way:
● Unscrew lock nut (Figure 4-1, A) on one of the cabinet feet using an open-end
wrench (wrench size = 13 mm).
● Adjust the height of the cabinet foot by turning the screw nut (Figure 4-1, B)
so that the cabinet is steady and the minimum clearance is observed.
● Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A).
4. Place the expansion cabinet beside the basic cabinet.
Note: The cabinets can be placed directly beside one another.
5. Check that the space between the base of the expansion cabinet and the ground
is at least 50 mm.
6. If necessary, set up the expansion cabinet as described in Step 3 ensuring that
both cabinets are at exactly the same level.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-13
inst_h3.fm
≥ 50 mm
Figure 4-4 HiPath 3800 - Installing a Two-Cabinet System Side by Side (Rear View)
P31003-H3560-S100-3-7620, 03/06
4-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Danger
7 Each HiPath 3800 system cabinet and all external main distribution frames (for ex-
ample, MDFU-E) must be grounded as shown in Figure 4-5 by a separate ground
conductor (minimum cross-section = 2.5 mm2). Make sure that the ground conductor
is securely installed and strain-relieved.
If external factors can impact on the ground conductor and if protected installation is
not possible, the ground conductor must have a minimum cross-section of 4 mm2.
Failure to follow these instructions can result in electrical shock.
The illustrations starting with Figure 4-6 show different grounding options.
Danger
7 If your personnel are not qualified to work on the low-voltage network (230 Vac), you
must hire a licensed electrician to ground the system separately using option 1b
(Figure 4-7).
To avoid ground loops from remotely operated devices (V.24 system peripherals),
> the devices should be connected to the same low-voltage network (sub-distribution
board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate
the external devices in the event of a malfunction.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-15
inst_h3.fm
e. g., MDFU-E
Figure 4-5 HiPath 3800 - Grounding the System Cabinets and Main Distribution Frame
(nor for U.S.)
P31003-H3560-S100-3-7620, 03/06
4-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Grounding option 1a
HiPath 3800
Main grounding terminal
green/yellow
Grounding option 1b
L1 N PE
Grounding outlets
230 V ~
HiPath 3800
Example Connector
socket Main grounding
terminal
green/yellow
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-17
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
120 VAC, 60 Hz
Neutral ground
DANGER
7 This wire installation must be completed by a qualified electrician and must
comply with the national and local electrical codes.
Figure 4-8 HiPath 3800 - Earth ground connection (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-19
inst_h3.fm
Procedure
Perform the tests in the table below to ensure that the system is properly grounded before star-
tup.
Prerequisites:
● HiPath 3800 is not yet connected to the low-voltage
network via the power cable.
● The system’s separate grounding is connected.
2. Check the ohmic resistance between the individual sys- < 1 ohm
tem parts (basic cabinet, expansion cabinet, main distri-
bution frame).
Prerequisite:
HiPath 3800 is not yet connected to the low-voltage net-
work via the power cable.
P31003-H3560-S100-3-7620, 03/06
4-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-21
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Caution
7 The height units represented in yellow in Figure 4-10 must be kept clear to ensure
adequate ventilation of the system cabinets.
Patch Panel
HiPath 3800
Expansion cabi-
net
Patch Panel
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-23
inst_h3.fm
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
P31003-H3560-S100-3-7620, 03/06
4-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Introduction
The cabinets are not supplied with pre-installed boards. For information on board installation,
please see Section 4.2.5, “Installing Boards (Configuration Notes)”.
If it has been agreed to provide connector panels for connecting peripherals, these are included
in the delivery. For information on the installation procedure, please see Section 4.2.5.4,
“Mounting Connector Panels (if required)”.
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before starting the system
and before connecting up the peripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Caution
7 To guarantee sufficient ventilation for the system cabinets, comply with the following
requirements:
● The basic cabinet may only be mounted at the lowest position in a 19-inch cab-
inet. In a 19-inch cabinet with active (heat-emitting) components already in-
stalled, the lowest position must be cleared for installation of the basic cabinet.
If inactive components (e.g. patch panel) are involved, the basic cabinet can
also be installed above them.
● A minimum clearance of three height units must be maintained between two
stacked system cabinets. A minimum clearance of one free height unit above a
system cabinet is sufficient if a patch panel is to be installed, for example.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-25
inst_h3.fm
Procedure
Warning
7 Never attempt to lift a system cabinet into the 19-inch cabinet without assistance.
Step Activity
1. Remove all four cabinet feet from the system cabinet.
To do this, unscrew the lock nuts (Figure 4-11, A) on the cabinet feet using an
open-end wrench (wrench size = 13 mm). Unscrew cabinet feet completely.
2. Attach the two angle brackets (A in Figure 4-12) to the sides of the system cabinet
using the screws that have been supplied (four per bracket).
3. Attach a right-handed and a left-handed support bracket (B in Figure 4-12) in the
19-inch cabinet using the screws provided.
Note: the use of cabinet floors is not permitted to prevent overheating.
4. Lift the system cabinet into the 19-inch cabinet and sit the cabinet on the two sup-
port brackets (B in Figure 4-12). Slide the cabinet into the 19-inch cabinet until the
front edge of the system cabinet is flush with the front of the 19-inch frame.
5. Secure the system cabinet using the two angle brackets (A, in Figure 4-12) on the
frame of the 19-inch cabinet using the screws provided.
Please note that a minimum clearance of three height units must be observed be-
tween two stacked system cabinets. A minimum clearance of one free height unit
above a system cabinet is sufficient if a patch panel is to be installed, for example.
6. Repeat steps 1 to 5 if you want to install an expansion cabinet.
P31003-H3560-S100-3-7620, 03/06
4-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-27
inst_h3.fm
YES
Does the 19-inch cabinet have NO A potential equalization bus must be installed in
a potential equalization bus at the 19-inch cabinet and connected to the ground
which the HiPath 3800 can be conductor.
grounded as shown in Figure 4- Danger
13 ? If your personnel are not qualified to work on the
low-voltage network (230 Vac), you must hire a li-
censed electrician to install the ground.
YES
If you answer “Yes” to both questions, the system (system cabinets, patch panels) may be
grounded as described below.
Danger
7 Each HiPath 3800 system cabinet and any patch panel (S30807-K6143-X) that may
be installed must be grounded as shown in Figure 4-13 by a separate ground con-
ductor (minimum cross-section = 2.5 mm2). Make sure that the ground conductor is
securely installed and strain-relieved.
If external factors can impact on the ground conductor and if protected installation is
not possible, the ground conductor must have a minimum cross-section of 4 mm2.
Please note:
The 19-inch cabinet’s potential equalization bus may only be used if it is grounded
by a separate ground conductor.
Failure to follow these instructions can result in electrical shock.
P31003-H3560-S100-3-7620, 03/06
4-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Figure 4-13 HiPath 3800- Grounding the Systems and Patch Panels in a 19-Inch Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-29
inst_h3.fm
To avoid ground loops from remotely operated devices (V.24 system peripherals),
> the devices should be connected to the same low-voltage network (sub-distribution
board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate
the external devices in the event of a malfunction.
Procedure
Perform the tests in the table below to ensure that the system is properly grounded before star-
tup.
Prerequisites:
● No device in the 19-inch cabinet is connected to the
low-voltage network via the power cable.
● The system’s separate grounding (basic cabinet, ex-
pansion cabinet, patch panel) and the grounding of
the 19-inch cabinet are connected.
2. Check the ohmic resistance between the individual sys- < 1 ohm
tem parts (basic cabinet, expansion cabinet, patch pan-
el).
Prerequisite:
HiPath 3800 is not yet connected to the low-voltage net-
work via the power cable.
P31003-H3560-S100-3-7620, 03/06
4-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards).
Caution
7 ● To ensure that the system operates without blocking, you must follow the instruc-
tions in Section 4.2.5.7 concerning PCM highway distribution.
● In a HiPath 3800 19-inch cabinet configuration, the IVMNL board may only be
installed in the basic cabinet to avoid overheating.
● To avoid inactive IVM channels caused by slow IVM board startup, the recom-
mendations on Page 3-121 must be followed.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-31
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Not used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-33
inst_h3.fm
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards).
Observe the measures for protecting electrostatically sensitive devices (see Page 1-
9).
Introduction
Peripheral boards can be inserted and removed while the power is connected. Always use the
board wrench provided for removing and inserting boards.
See Section 9.2.1 for information on upgrading peripheral boards.
If Then
Board is to Insert the tip of the board wrench marked “Pull” into the top opening on the front
be re- cover of the board to be removed.
moved. Lever the board out of the shelf by pushing the board wrench upwards (Figure 4-
16, left).
Then you can pull the module out of the system cabinet over the guide rails.
Board is to Using its guide rails slide the board into the system cabinet until it stops.
be added. Insert the tip of the board wrench marked “Plug In” into the bottom opening in the
front cover of the board.
Lever the board into the shelf of the cabinet by pushing the board wrench up-
wards (Figure 4-16, right).
P31003-H3560-S100-3-7620, 03/06
4-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Figure 4-16 HiPath 3800 - Removing/Inserting the Board Using the Board Wrench
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-35
inst_h3.fm
Boards that can be connected from the front have a specially shielded front cover. An additional
cover is not required.
Fixing screws
Fixing screws
Figure 4-18 HiPath 3800 - cPCI Box CSAPE in the Basic Cabinet with Panel Mounted
P31003-H3560-S100-3-7620, 03/06
4-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
● DBSAP
The DBSAP board is plugged into four socket contacts on the backplane of the expansion
cabinet and fixed with screws.
● LUNA2
Depending on the system configuration up to three LUNA2 modules can be used in the ba-
sic cabinet and up to four LUNA2 modules can be used in the expansion cabinet. For in-
formation on how to calculate the number of LUNA2 modules required, see the LUNA2
board description.
Push the LUNA2 power supply unit into the slots provided in the lower part of the system
cabinet shelf until you hear a click.
Removal tab
You can use a screw-
driver here to remove
the LUNA2 from the
shelf.
Figure 4-19 HiPath 3800 - Installing the LUNA2 Power Supply Unit
The slots for the power supply units must be covered with an outer panel before the system
is started up. The outer panel is fixed onto the shelf with screws (see Figure 4-20 and
Figure 4-21).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-37
inst_h3.fm
Fixing screws
Figure 4-20 HiPath 3800 - Slots for LUNA2 and REALS in the Basic Cabinet (With Out-
er Panel Mounted)
Fixing screws
Figure 4-21 HiPath 3800 - Slots for LUNA2 in the Expansion Cabinet (With Outer Panel
Mounted)
P31003-H3560-S100-3-7620, 03/06
4-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
● REALS
Insert the REALS board into the slot marked 3 in the lower part of the shelf in the basic
cabinet and apply pressure until you hear a click.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-39
inst_h3.fm
If Then
Connector panels Slot with Attach a connector panel with 8 RJ45 jacks (S30807-
with RJ45 jacks STMD3 Q6624-X) to the SIVAPAC connector on the back-
(see plane.
Section 4.2.6.5) Slot with Attach a connector panel with 24 RJ45 jacks (S30807-
SLCN Q6622-X) to the SIVAPAC connector on the back-
SLMA plane.
SLMA21
SLMA8
SLMO2
SLMO8
TM2LP
TMC161
TMDID2
different or no as- Use filler panels to cover the backplane sections of
signment other boards and empty board slots.
For U.S. only: Slot with Attach a connector panel with CHAMP jacks (S30807-
Connector panels SLMA Q6626-X) to the SIVAPAC connector on the back-
with CHAMP jack SLMA21 plane.
(see SLMA8
Section 4.2.6.6) SLMO2
SLMO8
STMD3
TM2LP
TMC161
TMDID2
different or no as- Use filler panels to cover the backplane sections of
signment other boards and empty board slots.
P31003-H3560-S100-3-7620, 03/06
4-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
If Then
Connector panels Slot with Plug a connector panel with SIPAC 1 SU connectors
with SIPAC 1 SU SLCN (S30807-Q6631-X) into the SIVAPAC connector on
connectors SLMA the backplane.
(see SLMA21
Section 4.2.6.7) SLMA8
SLMO2
SLMO8
STMD3
TM2LP
TMC161
TMDID2
different or no as- Use filler panels to cover the backplane sections of
signment other boards and empty board slots.
1 for selected countries only
2 for U.S. only
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-41
inst_h3.fm
Adapter modules
Startup module
Component
side
board
P31003-H3560-S100-3-7620, 03/06
4-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Step Activity
1. Rotate the board so that the backplane connector is pointing towards you.
2. Carefully pull the locking hooks (Figure 4-24, A) on an adapter module apart.
3. Align the adapter module on the connector strip (Figure 4-24, B) of the board. The
outside edges of the adapter module must match the outside edges of the connector
strip.
4. Make sure that the outermost row of pins on the adapter module and the outermost
row of jacks on the connector strip are aligned flush with one another and press the
adapter module fully into the connector strip.
5. Close the locking hooks.
6. Repeat steps 2 to 5 to install the second adapter module.
7. Plug the startup module (Figure 4-24, C,) into the hotplug connector on the board.
A A
B B
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-43
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Expansion cabinet
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Basic cabinet
1 2 3 4 5 6 7 8 9 10
C
B
S
A
P
Figure 4-26 HiPath 3800 - Initialization of Subscriber Line Circuits and Ports
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-45
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
– PCM segment for board slots 7 – 10 = 128 time-division multiplex channels (four PCM
highways)
DIUN2, DIU2U (for U.S. only) and STMI2 use the PCM highways from bundle F. Thus there
are an additional 128 time-division multiplex channels available for slots 1 – 5 and for slots
7 – 10 for these boards.
If more than the 2 x 128 time-division multiplex channels from bundle F are required be-
cause of the configuration with these boards, the system will automatically resort to time-
division multiplex channels from bundle A. However, only complete boards are activated on
the other trunk group. The remaining time-division multiplex channels remain free.
● Two-cabinet system (basic cabinet + expansion cabinet)
All peripheral boards use the PCM highways from bundle A only.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-47
inst_h3.fm
Table 4-4 Maximum Number of Time-Division Multiplex Channels Required Per Board
P31003-H3560-S100-3-7620, 03/06
4-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Table 4-4 Maximum Number of Time-Division Multiplex Channels Required Per Board
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-49
inst_h3.fm
HiPath 3800 Slots per PCM seg- Static traffic capac- Total static traffic
ment ity per PCM seg- capacity of the
ment system
1–5 128 erlangs +
Single-cabinet sys- (128 erlangs1)
tem 512 erlangs
(see Page 4-46) 7 – 10 128 erlangs +
(128 erlangs1)
1–5 128 erlangs
Two-cabinet system 7 – 10 128 erlangs
512 erlangs
(see Page 4-47) 11 – 16 128 erlangs
18 – 24 128 erlangs
1 The basic cabinet provides two PCM highway bundles with 2 x 4 PCM highways each. DIUN2, DIU2U (for U.S. only)
and STMI2 use the PCM highways from bundle F. Thus there are an additional 128 time-division multiplex channels
available for slots 1 – 5 and for slots 7 – 10 for these boards in the basic cabinet. If HiPath 3800 is used as a two-
cabinet system, a use of PCM highway bundle F is not possible.
P31003-H3560-S100-3-7620, 03/06
4-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
All cables that leave the system cabinet must be attached to the metal back panel
> using cable ties.
Connection options
Peripheral devices can be connected up to the HiPath 3800 in a number of different ways:
● SIVAPAC connector on the backplane for connecting the external main distribution frame
via CABLUs (prefabricated cabling units) or for connecting external patch panels (see
Section 4.2.6.4).
● Connector panels with RJ45 jacks for direct connection of peripherals (see
Section 4.2.6.5). The connector panels are clipped onto the SIVAPAC connectors on the
backplane.
● For U.S. Only: Connector panels with CHAMP jack for direct connection of peripherals (see
Section 4.2.6.6). The connector panels are clipped onto the SIVAPAC connectors on the
backplane.
● Connector panels each with two SIPAC 1 SU connectors for connecting the external mail
distribution frame MDFU-E or external patch panels using CABLUs (see Section 4.2.6.7).
The connector panels are clipped onto the SIVAPAC connectors on the backplane.
The type of connection used will be decided in consultation with the customer on conclusion of
the agreement. The cabinets will be delivered accordingly with or without clipped-on connector
panels.
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-51
inst_h3.fm
9 SIVAPAC connec-
tor for peripherals
P31003-H3560-S100-3-7620, 03/06
4-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
X105
X104
X103
X102
X101
X112
X111
X110
X109
X201
X209
X214
X116
X212
X211
Figure 4-30 HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-53
inst_h3.fm
Table 4-6 HiPath 3800 - Assignment of Connectors and Jacks on the Backplane of the
Basic Cabinet
Connector Function
X101 – X105 SIVAPAC connector for connecting peripherals:
X109 – X112 CABLUs and open-end cables are used for connection to the MDFU-E or to
an external patch panel (see Section 4.2.6.4).
Note: The SIVAPAC connectors can have the following connector panels:
● Connector panels with RJ45 jacks for direct connection of peripherals
(see Section 4.2.6.5).
● For U.S. only: Connector panels with CHAMP jack for direct connection
of peripherals (see Section 4.2.6.6).
● Connector panels each with two SIPAC 1 SU connectors for connecting
an external main distribution frame or external patch panel using CABLUs
(see Section 4.2.6.7).
For selected countries only: PBXXX board: An APPCU adapter (S30807-
K5415-X) is used to connect the CAS cable and the DIUN2 connection cable.
X116 SIVAPAC connectors for picking up the signals from the REALS board.
CABLUs for connection to the MDFU-E (jumper strip for 25 TW):
● C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E
slots 11-21 (see Figure 4-37)
● C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-37)
Open-end cable (24 TW) for connection to an external patch panel:
● S30267-Z196-A150: 15 m in length
● S30267-Z196-A250: 25 m in length
● S30267-Z196-A350: 35 m in length
● S30267-Z196-A550: 55 m in length
● S30267-Z196-A950: 95 m in length
X201 68-pin DB68 mini-jack for connecting the cable C39195-Z7611-A10 to the ex-
pansion cabinet (for the DBSAP board)
X209 DC port
X211, X212 AC power
X214 10-pin connection for the ring voltage generator RGMOD (for selected coun-
tries only)
P31003-H3560-S100-3-7620, 03/06
4-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
13 SIVAPAC connectors
for peripheral boards
DB68 mini-jack (connec-
DC port
tion to BC)
AC port
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-55
inst_h3.fm
X114
X113
X112
X111
X110
X109
X106
X105
X104
X103
X102
X101
X214
X209
X223
X220 –
X211
Figure 4-32 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion Cab-
inet
P31003-H3560-S100-3-7620, 03/06
4-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Table 4-7 HiPath 3800 - Assignment of Connectors and Jacks on the Backplane of the
Expansion Cabinet
Connector Function
X101 – X106 SIVAPAC connector for connecting peripherals:
X109 – X115 CABLUs and open-end cables are used for connection to the MDFU-E or to
an external patch panel (see Section 4.2.6.4).
Note: The SIVAPAC connectors can have the following connector panels:
● Connector panels with RJ45 jacks for direct connection of peripherals
(see Section 4.2.6.5).
● For U.S. only: Connector panels with CHAMP jack for direct connection of
peripherals (see Section 4.2.6.6).
● Connector panels each with two SIPAC 1 SU connectors for connecting
an external main distribution frame or external patch panel using CABLUs
(see Section 4.2.6.7).
For selected countries only: PBXXX board: An APPCU adapter (S30807-
K5415-X) is used to connect the CAS cable and the DIUN2 connection cable.
X209 DC port
X211 AC power
X214 10-pin connection for the ring voltage generator RGMOD (for selected coun-
tries only)
X220 – X223 Connections for plugging in the DBSAP board.
DBSAP has a 68-pin DB68 mini-jack for connecting the cable C39195-Z7611-
10 to the basic cabinet (to the jack X201).
To ensure smooth operation, use only shielded cables with a maximum length of
> 1 m.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-57
inst_h3.fm
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Use the CABLUs (prefabricated cabling units) that are listed in the following table to establish
the connection with the MDFU-E. Open-end cables must be used if an external patch panel is
being used. See also Section 4.2.7, “Using an External Main Distribution Frame or External
Patch Panel”.
If Then
Slot with CABLUs for connection between backplane (SIVAPAC connector) and
SLCN MDFU-E (splitting strip for 16 TW):
SLMA8 ● C39195-A7267-A370: 3 m in length, short stripped length for MDFU-E
SLMO8 slots 11-21 (see Figure 4-37)
STMD3 ● C39195-A7267-A371: 3 m in length, long stripped length for MDFU-E
TM2LP slots 1-10 (see Figure 4-37)
TMC161 CABLU for connection between backplane (SIVAPAC connectors) and ex-
TMDID2 ternal patch panel S30807-K6143-X (SIVAPAC socket terminal strip):
● S30267-Z333-A20: 2 m in length (refer to Figure 4-43)
● S30267-Z333-A50: 5 m in length (refer to Figure 4-43)
Open-end cable (24 TW) for connection between backplane (SIVAPAC con-
nector) and external patch panel:
● S30267-Z196-A150: 15 m in length
● S30267-Z196-A250: 25 m in length
● S30267-Z196-A350: 35 m in length
● S30267-Z196-A550: 55 m in length
● S30267-Z196-A950: 95 m in length
P31003-H3560-S100-3-7620, 03/06
4-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
If Then
Slot with CABLUs for connection between backplane (SIVAPAC connector) and
SLMA MDFU-E (jumper strip for 25 TW):
SLMA21 ● C39195-A7267-A372: 3 m in length, short stripped length for MDFU-E
SLMO2 slots 11-21 (see Figure 4-37)
● C39195-A7267-A373: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-37)
CABLU for connection between backplane (SIVAPAC connectors) and ex-
ternal patch panel S30807-K6143-X (SIVAPAC socket terminal strip):
● S30267-Z333-A20: 2 m in length (refer to Figure 4-43)
● S30267-Z333-A50: 5 m in length (refer to Figure 4-43)
Open-end cable (24 TW) for connection between backplane (SIVAPAC con-
nector) and external patch panel:
● S30267-Z196-A150: 15 m in length
● S30267-Z196-A250: 25 m in length
● S30267-Z196-A350: 35 m in length
● S30267-Z196-A550: 55 m in length
● S30267-Z196-A950: 95 m in length
Slot with A CAS cable is connected via an APPCU adapter (S30807-K5415-X).
PBXXX1
1 for selected countries only
2 for U.S. only
After the cable has been connected, the backplane of the basic cabinet and that of
> the expansion cabinet (if applicable) must be closed with the dummy panels provid-
ed (C39165-A7075-C44).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-59
inst_h3.fm
Figure 4-33 HiPath 3800 - Backplane of the Basic Cabinet with Mounted Filler Panels
P31003-H3560-S100-3-7620, 03/06
4-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
8 1
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Connect the peripheral directly to the 8-pin RJ45 jacks on the connector panels.
If Then
Slot with Connector panel with eight RJ45 jacks: S30807-Q6624-X
STMD3 The RJ45 jacks are configured with four wires. S0 stations can be directly
connected (1:1 cable). The receive and send lines should be switched for
trunk connections.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-61
inst_h3.fm
If Then
Slot with Connector panel with 24 RJ45 jacks: S30807-Q6622-X
SLCN The RJ45 jacks are configured with two wires.
SLMA
SLMA21
SLMA8
SLMO2
SLMO8
TM2LP
TMC161
TMDID2
different or no The backplane sections of other boards and empty board slots must be cov-
assignment ered with filler panels.
1 for selected countries only
2 for U.S. only
P31003-H3560-S100-3-7620, 03/06
4-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
4.2.6.6 For U.S. only: Connecting Peripherals to the Connector Panels with CHAMP
Jack
The boards should be installed in the cabinets as described in Section 4.2.5. The S30807-
Q6626-X connector panels attached to the SIVAPAC connectors on the backplane are
equipped with a CHAMP jack.
Figure 4-35 HiPath 3800 - Connector Panel with CHAMP Jack (for U.S. only)
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Connect the peripheral directly to the CHAMP jack in the connector panels.
If Then
Slot with periph- A cable with CHAP jack should be used to connect to a main distributor
eral card frame or external patch panel.
No assignment The backplane sections with empty board slots must be covered with filler
panels.
Information on cable and connector assignment is provided in the board descriptions in
Chapter 3.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-63
inst_h3.fm
Figure 4-36 HiPath 3800 - Connector Panel with Two SIPAC 1 SU Connectors (S30807-
Q6631-X)
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets to
the grounding point of the electrical building installation before connecting up the pe-
ripherals (for example, potential equalization bus).
The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
Use the CABLUs that are listed in the following table to establish the connection with the
MDFU-E or an external patch panel. See also Section 4.2.7, “Using an External Main Distribu-
tion Frame or External Patch Panel”.
In special cases where the prefabricated CABLUs cannot be used, open-end cables should be
used.
P31003-H3560-S100-3-7620, 03/06
4-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
If Then
Slot with CABLUs for connection between connector panel (SIPAC 1 SU connectors)
SLCN and MDFU-E (splitting strip for 16 TW):
SLMA8 ● S30269-Z100-A11: 3 m in length, short stripped length for MDFU-E
SLMO8 slots 11-21 (see Figure 4-37)
STMD3 ● S30269-Z100-A21: 3 m in length, long stripped length for MDFU-E slots
TM2LP 1-10 (see Figure 4-37)
TMC161 CABLU with 16 TW for connection between connector panel (SIPAC 1 SU
TMDID2 connectors) and external patch panel S30807-K6143-X (SIVAPAC socket
terminal strip):
● S30267-Z362-A20: 2 m in length (refer to Figure 4-43)
Open-end cable (16 TW) for connection between backplane (SIPAC 1 SU
connectors) and external patch panel:
● S30267-Z192-A60: Open-end cable with 16 TW, 6 m in length
● S30267-Z192-A100: Open-end cable with 16 TW, 10 m in length
● S30267-Z192-A200: Open-end cable with 16 TW, 20 m in length
(Information on the required stripped lengths for open-end cables is
provided in Figure 4-48.)
Slot with CABLUs for connection between connector panel (SIPAC 1 SU connectors)
SLMA and MDFU-E (jumper strip for 25 TW):
SLMA21 ● S30269-Z100-A14: 3 m in length, short stripped length for MDFU-E
SLMO2 slots 11-21 (see Figure 4-37)
● S30269-Z100-A24: 3 m in length, long stripped length for MDFU-E slots
1-10 (see Figure 4-37)
CABLU with 24 TW for connection between connector panel (SIPAC 1 SU
connectors) and external patch panel S30807-K6143-X (SIVAPAC socket
terminal strip):
● S30267-Z363-A20: 2 m in length (refer to Figure 4-43)
Open-end cable (16 TW) for connection between backplane (SIPAC 1 SU
connectors) and external patch panel:
● S30267-Z192-A60: Open-end cable with 16 TW, 6 m in length
● S30267-Z192-A100: Open-end cable with 16 TW, 10 m in length
● S30267-Z192-A200: Open-end cable with 16 TW, 20 m in length
(Information on the required stripped lengths for open-end cables is
provided in Figure 4-48.)
different or no The backplane sections of other boards and empty board slots must be cov-
assignment ered with filler panels.
1 for selected countries only
2 for U.S. only
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-65
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
328.8 mm
4
Jumpering
5 Channel
6 21 slots (9 x 30 mm)
669.0 mm
19
20
21
Special built-in
comps.
2 x PFT1
or
Figure 4-37 MDFU-E - Layout and Dimensions (669.0 x 328.8 x 125.4 mm)
Not more than 21 CABLUs per MDFU-E with one 16-TW strip or 25-TW strip (9 x 30 mm) can
be implemented.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-67
inst_h3.fm
Step Activity
1. Use the template to drill the holes.
2. Insert the wall anchors and screw in the screws, leaving 5 mm projecting.
3. Remove the housing cover and mount the MDFU-E on the brackets.
4. Tighten the screws through the holes.
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets and
all main distribution frames to the grounding point of the electrical building installa-
tion before connecting up the peripherals (for example, potential equalization bus).
Surge protector
To divert surges caused by lightning, insert surge protectors on
● lines that leave the system buildings (outside stations)
● lines > 500 m long.
Connect the polarized surge protectors to the plugging locations on the splitting strip described
above (see Figure 4-39).
P31003-H3560-S100-3-7620, 03/06
4-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
a
b
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
a
b
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
a
b
1 3 5 7 9 11 13 15 17 19 21 23 25
No. 25 not used
Jumper strip for 25 TW (C39334-A166-A3)
Figure 4-38 Assignment (Numbering) of the Splitting/Jumper Strips (view from above)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-69
inst_h3.fm
a 1 a
b
1
b
a 2 a
b 2
Example for connecting b
a 3 a
b the wires 3
b
a 4 a
b 4
b
a 5 a
b 5
b
a 6 a
b 6 b
a 7 a
b 7 b
a 8 a
b 8 b
a a
9 9 b
b
a 10 a
10 b
b
a 11 a
11 b
b
a 12 a
12 b
b
a 13 a
b
13 b
View from below a
View from above (surge
a 14 14
b b protector plug locations)
a 15 a
b 15 b
a 16 a
b 16 b
Cable with film sheath: No. 6 (conductive copper tape) 1.5 windings. Ground wire
shortened to 25 mm and soldered onto conductive tape (1).
Stripped length
Stripped length = 600 ± 5 mm
250 ± 5
(1) Stripped length = 910 ± 5 mm for
MDFU-E slots 1 to 10
P31003-H3560-S100-3-7620, 03/06
4-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-71
inst_h3.fm
Structure
All incoming cables must be attached to the patch panel using cable ties.
>
SIVAPAC edge connector: port for
CABLU connection to the backplane
P31003-H3560-S100-3-7620, 03/06
4-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Installation procedure
Caution
7 The patch panel must be installed above the system cabinet.
A minimum of one height unit must be kept clear above the cabinet to guarantee suf-
ficient ventilation of the system cabinet. This is achieved by the gray plastic cover
fixed to the top of the system cabinets. Never remove this plastic cover.
Insert the patch panel (A, in Figure 4-41) above the system cabinet and secure it to the 19-inch
frame on both the left and the right using two screws on each side.
A
B
Figure 4-41 Installing the External Patch Panel in the 19-Inch Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-73
inst_h3.fm
Danger
7 Be sure to connect the main protective earthing terminal on all system cabinets and
all patch panels to the grounding point of the electrical building installation before
connecting up the peripherals (for example, potential equalization bus).
Telephones and trunks are connected directly to the MW8 jack on the front of the patch panel.
Information on MW8 jack assignment on the front of the patch panel is provided in the board
descriptions (in the “Cable and Connector Assignment” table) in Chapter 3.
Surge protector
To divert surges caused by lightning, insert surge protectors on
● lines that leave the system buildings (outside stations)
● lines > 500 m long.
Connect the polarized surge protectors to the plugging locations F1 to F8 provided on the patch
panel (see Figure 4-43).
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
Example 1
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
Example 2
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
Example 3
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
Figure 4-42 Layout of the Patch Panel S30807-K6143-X for Different Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
4-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
X5 X1
X11
1 X12 1 X9 X9, X10, X11 and PFT1 not
1 X13 1 X10 used in HiPath 3000.
1 X14
1 X15
F1 F4 F6 F8 Slots F1–F8 for PFT1
surge protector
F2 F3 F5 F7
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 2 3 4 5 6 7 8 X12, X14
1 2 3 4 5 6 7 8
X13, X15
1 2 3 4 5 6 7 8
a b a b a b a b a b a b a b a b
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-75
inst_h3.fm
Structure
All incoming cables must be attached to the patch panel using cable ties.
>
3 x 8 MW8 jacks
P31003-H3560-S100-3-7620, 03/06
4-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Installation Procedure
Caution
7 The patch panel must be installed above the system cabinet.
A minimum of one height unit must be kept clear above the cabinet to guarantee suf-
ficient ventilation of the system cabinet. This is achieved by the gray plastic cover
fixed to the top of the system cabinets. Never remove this plastic cover.
Insert the S0 patch panel (A, in Figure 4-45) above a system cabinet and secure it to the 19-
inch frame on both the left and the right using two screws (B) on each side.
A
B
Figure 4-45 Installing the External S0 Patch Panel in the 19-Inch Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-77
inst_h3.fm
24 22 20 18 ... ... 8 6 4 2
23 21 19 17 ... ... 7 5 3 1
87632145
Pin assignment of MW8 jacks
Twist the wire pairs before laying them.
Figure 4-47 Laying Wire Pairs at the S0 Patch Panel
P31003-H3560-S100-3-7620, 03/06
4-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Stripped length
250 ± 5
(1)
Cable with film sheath: No. 6 (conductive copper tape) 1.5 windings. Ground wire shortened
to 25 mm and soldered onto conductive tape (1).
Stripped length = 600 mm ± 5 mm
Figure 4-48 Stripping the Open-End Cable for the S0 Patch Panel
The color codes for open-end cables are provided in Table 4-8.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-79
inst_h3.fm
DANGER
7 Ground the system properly before connecting the stations.
Caution
7 The TMST2 Module can only be installed in conjunction with a listed channel service
unit CSU.
Secondary Protection
DANGER
7 To protect against surge voltage caused by lightning, the following boards require
secondary protection when their lines leave the building where the main distribution
frame is housed:
● DIU2U*
● SLMA / SLMA8
● TMC16
● TMDID
● TMEW2
● TM2LP
* When this module is connected to the public network, secondary protection must
be provided by the CSU.
P31003-H3560-S100-3-7620, 03/06
4-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards). Connect the wristband to the slide-in shelf in the cabinet using the
alligator clip.
The boards should be installed in the cabinets as described in Section 4.2.5.
The central control boards are not always fully equipped when delivered. Optional plug-in
boards are packaged individually.
See Section 3.2.4 for information on slots for subboards on the central control board CBSAP.
Caution
7 Place the central control board on a flat surface before installing subboards.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-81
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3800
Introduction
Before starting up the system, you must perform a visual inspection of the hardware, cables,
and the power supply. The procedure is shown in Table 4-9. The visual inspection must be per-
formed while the system is disconnected from the power supply.
Caution
7 Before beginning work, make sure that the system is grounded and disconnected
from the power supply.
Observe the measures for protecting electrostatically sensitive devices (see Page 1-
9).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-83
inst_h3.fm
After finishing the visual inspection, you can begin starting up the HiPath 3800 as
> described in Chapter 5.
P31003-H3560-S100-3-7620, 03/06
4-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Warning
7 Only authorized service personnel should install and start up the system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-85
inst_h3.fm
5. Grounding the System, page 4-108 Grounding the System, page 4-136
Checking the Grounding, page 4-113 Checking the Grounding, page 4-138
6. Connecting the Cable to the Backplane, Connecting the Cable to the Backplane,
page 4-114 page 4-139
7. Laying the Line Network and Setting Connecting the Line Network to the Patch
Jumpers on the MDFU or MDFU-E, page Panel, page 4-152
4-124
8. Loading the System Software and Installing Subboards on the CBCPR, page 4-153
9. Configuration notes, page 4-154 (cabinet(s) are already equipped with the boards)
10. Connecting Workpoint Clients, page 4-163
P31003-H3560-S100-3-7620, 03/06
4-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-87
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Selecting a site
The customer usually has a preferred installation site in mind.
Make sure that the customer’s site meets the following guidelines:
● To guarantee sufficient system ventilation, allow a minimum of 10 cm clearance in front of
and behind the housing.
● Do not expose the systems to direct sources of heat (for example sunlight and heaters).
● Do not expose the systems to extremely dusty environments.
● Avoid contact with chemicals.
● Take every precaution to prevent the formation of condensation on the system during op-
eration. Systems covered with condensation must be dried before being used.
● Observe the environmental conditions specified in Section 2.11.
For U.S. Only:
● Install secondary-protection equipment.
● Avoid standard carpeting, as it tends to produce electrostatic charges.
● Ensure the availability of a power source that meets the requirements described in
Section 4.3.3.1.1.
● Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The
National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical
equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment.
● The equipment room for the system should provide adequate space for installation and
maintenance activities (such as removing and replacing boards). Leave at least 16 in. (42
cm) on all sides of the system, and 36 in. (16 cm) in front.
Information on the design of the HiPath 3750 can be found in Section 2.2.2.2.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-89
inst_h3.fm
WARNING
7 Never connect a HiPath 3750system or a combination of HiPath 3750systems direct-
ly to a wall socket. Use a UL-listed or CSA-certified surge protector for every two
cabinets.
P31003-H3560-S100-3-7620, 03/06
4-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-91
inst_h3.fm
Introduction
The following are used as main distribution frames:
● MDFU-E, which is shipped with new systems (see Figure 4-72).
● the MDFU (one MDFU unit per system cabinet), which was used for Hicom 150 E OfficePro
in Release 2.0 and earlier (see Figure 4-71).
Installation notes
The main distribution frame should be installed in the direct vicinity of the system (note length
of connection cable) and at eye level. Mount it on the wall according to the instructions that
came with it. The bag attached to the cover contains a drill template. It also contains the nec-
essary screws and wall anchors for attaching the MDF to the wall.
Step Activity
1. Use the template to drill holes.
2. Insert the wall anchors and screw in the screws, leaving 5 mm projecting.
3. Remove the housing cover. Attach the main distributor frame to the brackets and
remove the packing protection covering.
4. Tighten the screws through the holes.
P31003-H3560-S100-3-7620, 03/06
4-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Warning
7 A fully equipped HiPath 3750 cabinet weighs 22 kg (48.46 lb). We recommend lifting
cabinets only before they are equipped. Do not attempt to lift objects that you think
are too heavy for you; use a hand truck or get assistance.
Introduction
Cabinets are supplied fitted with the specific boards required by the customer.
Danger
7 Be sure to ground the system properly before starting it up and connecting the sta-
tions.
4.3.3.4.1 Overview
System configurations
The following setup options are possible for system cabinets:
System
One cabinet on a horizontal surface
One cabinet on a wall (for U.S. only)
Two cabinets stacked on a horizontal surface
Two cabinets stacked on a wall (for U.S. only)
Two cabinets side-by-side on a horizontal surface
Three cabinets on a horizontal surface (two stacked)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-93
inst_h3.fm
Step Activity
1. Insert a slotted screwdriver (with the blade vertical) into a recess (1).
2. Carefully swing the handle of the screwdriver toward the center of the cabinet (2)
until the fastener snaps out and the cover loosens.
3. Then insert the screwdriver in the second recess (3), loosen its snap fastener.
Cabinet
(3)
(1)
(2)
Figure 4-49 HiPath 3750 - Removing the Front and Rear Covers
P31003-H3560-S100-3-7620, 03/06
4-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Step Activity
1. Remove the front and rear cover from the cabinet.
2. Place the system cabinet in the installation site and make sure that it is level and
stable.
Wall-Mount Kit
Keyed holes
Latch
Swing-out component
Procedure
Step Activity
1. Install a plywood backboard at least 0.75 in. (19.05 mm) thick.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-95
inst_h3.fm
Step Activity
2. Use the wall-mounting bracket as a template to drill three holes in the backboard.
Use the keyed holes in the top of the bracket and the round hole in the bottom of the
bracket.
3. Install the screws in the top two holes, tightening them until 0.25 in. (6.35 mm) is pro-
truding.
4. Bolt the swing-out assembly on the wall-mounting bracket to the back of the cabinet.
5. Close the swing-out assembly; Then mount the bracket and cabinet on the top
screws.
6. Swing the cabinet open and tighten the top screws completely.
7. Insert and fully tighten the bottom screw in the round hole.
8. Bolt the latching assembly to the opposite edge of the cabinet.
You can invert the bracket to have the cabinet swing out in the opposite direction.
WARNING
7 Do not fasten power cords to building surfaces when mounting cabinets on the wall.
Figure 4-51 HiPath 3750 Mounting a One-Cabinet System on the Wall (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
4-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Step Activity
1. Remove the front and rear cabinet covers.
2. Mount stabilizer feet on basic cabinet (BC). Place the basic cabinet in the instal-
lation site and make sure that it is level and stable.
3. Place expansion cabinet (EC1) on basic cabinet. Insert the feet on EC1 into the
depressions on the top of the BC.
4. If mounting the system on the floor or on a table, attach the two cabinets using
four connecting plates each held by two screws with washers (Figure 4-52).
Make sure that the connecting plates are mounted in the correct direction (inside
the cabinets and pointing inward).
DANGER
7 The connecting plates must be installed to ensure proper grounding for free-stand-
ing systems.
For U.S. only: You can install seismic anchors for greater stability, as is required in
> some installations. Additional information can be found in Section 4.3.3.4.9.
Take note that the bolts and inserts included in the seismic anchor kit are designed
for concrete floors. Bolts for other surfaces must be requested or supplied separate-
ly.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-97
inst_h3.fm
EC1
EC1
Inside
the cabinet
BC
BC Washers
Caution
7 Be careful when breaking out the recesses. Remove any sharp edges and corners.
P31003-H3560-S100-3-7620, 03/06
4-98 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Caution
7 Always mount the stabilizer feet on stacked, surface-mounted system cabinets to
ensure stability (Figure 4-53).
Step Activity
1. Place the stabilizer feet beneath the right and left outer edges of the cabinets. In-
sert the cabinet feet into the two holes in the stabilizer feet (1).
2. Attach the stabilizer feet to the metal housing of the cabinet (2) by inserting two
screws per foot into the pre-drilled holes in the housing.
3. Continue installing the system.
(2)
(2)
(1)
(1) (2)
Figure 4-53 HiPath 3750 - Mounting the Stabilizer Feet (Three-Cabinet System Shown)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-99
inst_h3.fm
4.3.3.4.6 For U.S. only: Mounting Two Cabinets Stacked on the Wall
You can mount two cabinets stacked on the wall using the wall-mount kit.
DANGER
7 The second cabinet also requires an earth ground as described on
Section 4.3.3.5.2. Do not fasten wall-mounted cabinets with the connecting plates,
as this will interfere with the earth ground.
Wall-Mount Kit
Keyed holes
Latch
Swing-out component
Procedure
Step Activity
1. Install a plywood backboard at least 0.75 in. (19.05 mm) thick.
2. Use the wall-mounting bracket as a template to drill three holes in the backboard.
Use the keyed holes in the top of the bracket and the round hole in the bottom of the
bracket.
3. Install the screws in the top two holes for each bracket, tightening them until 0.25 in.
(6.35 mm) is protruding.
P31003-H3560-S100-3-7620, 03/06
4-100 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Step Activity
4. Bolt the swing-out assembly on the wall-mounting bracket to the back of each cab-
inet.
5. Close the swing-out assembly; Close the swing-out assembly and hang each brack-
et and cabinet on the top screws.
6. Swing the cabinet open and tighten the top screws completely.
7. Insert and fully tighten the bottom screws in the round holes.
8. Bolt the latching assembly to the opposite edge of each cabinet.
You can invert the wall brackets to have the cabinets swing out in the opposite direction.
Warning
7 Do not fasten power cords to building surfaces when mounting cabinets on the wall.
Figure 4-55 HiPath 3750 Wall Mounting for a Stacked Two-Cabinet System (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-101
inst_h3.fm
Warning
7 Be careful when breaking out the recesses. Remove any sharp edges and corners.
P31003-H3560-S100-3-7620, 03/06
4-102 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Step Activity
1. Remove the front and rear cabinet covers.
2. Place the system cabinets side by side at the installation site and make sure that
they are level and stable. Correct any differences in height.
3. If mounting the system on the floor or on a table, attach the two cabinets using
four connecting plates each held by two screws with washers (Figure 4-56).
Make sure that the connecting plates are mounted in the correct direction (inside
the cabinets and pointing inward).
DANGER
7 The connecting plates must be installed to ensure proper grounding for free-stand-
ing systems.
BC EC1 BC EC1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-103
inst_h3.fm
Caution
7 Up to two cabinets can be stacked.
Procedure
Step Activity
1. Remove the front and rear cabinet covers.
2. Mount one stabilizer foot on the basic cabinet and one on the expansion cabinet
(EC2). Place EC2 next to the BC in the installation site and make sure that it is
level and stable. Correct any differences in height.
3. Place expansion cabinet (EC1) on basic cabinet. Insert the feet on EC1 into the
depressions on the top of the BC.
4. Attach the three cabinets using four connecting plates, each held by two screws
with washers (Figure 4-57).
Make sure that the connecting plates are mounted in the correct direction (inside
the cabinets and pointing inward).
DANGER
7 The connecting plates must be installed to ensure proper grounding for free-stand-
ing systems.
For U.S. only: You can install seismic anchors for greater stability, as is required in
> some installations. Additional information can be found in Section 4.3.3.4.9.
Take note that the bolts and inserts included in the seismic anchor kit are designed
for concrete floors. Bolts for other surfaces must be requested or supplied separate-
ly.
P31003-H3560-S100-3-7620, 03/06
4-104 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
EC1
BC
BC EC2
EC2
Caution
7 Be careful when breaking out the recesses. Remove any sharp edges and corners.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-105
inst_h3.fm
Local building codes may require the use of seismic anchors in critical locations,
> such as hospitals. The HiPath 3750 seismic anchor kit includes bolts and attach-
ments specially designed for concrete floors. If necessary, consult the location plan-
ner to check legal requirements or whether the customer requires seismic anchors
for a different substrate.
Procedure
Step Activity
1. Hook the anchor into the center holes in the lower grill on each cabinet (front and
back).
2. Bolt the anchor to the floor using the holes provided.
The anchor for the back of the cabinets is wider to provide space for cables.
Seismic Anchoring
Front Back
P31003-H3560-S100-3-7620, 03/06
4-106 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Figure 4-59 HiPath 3750 Seismic Anchoring for Multiple Cabinets (Front View) (for U.S.
only)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-107
inst_h3.fm
Danger
7 The HiPath 3750 system and the MDFU or MDFU-E must be grounded as shown in
Figure 4-60 by a separate ground conductor (minimum cross-section = 2.5 mm2)
Make sure that the ground conductor is securely installed and strain-relieved.
Failure to follow these instructions can result in electrical shock.
If one or two ECs are required in addition to the BC, the four metal connecting plates must be
installed to properly ground these cabinets.
The illustrations starting with Figure 4-61 show different grounding options.
Danger
7 If your personnel are not qualified to work on the low-voltage network (230 Vac), you
must hire a licensed electrician to ground the system separately using option 1b
(Figure 4-62).
To avoid ground loops from remotely operated devices (V.24 system peripherals),
> the devices should be connected to the same low-voltage network (sub-distribution
board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate
the external devices in the event of a malfunction.
P31003-H3560-S100-3-7620, 03/06
4-108 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
HiPath 3750, BC
to the second and third MDFU (if
present)
MDFU, MDFU-E
Figure 4-60 HiPath 3750 - Grounding the System Cabinets and Main Distribution Frame
(not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-109
inst_h3.fm
Grounding option 1a
HiPath 3750
green/yellow
Grounding option 1b
L1 N PE
Grounding outlets
230 V ~
HiPath 3750
Example Connector
socket
green/yellow
P31003-H3560-S100-3-7620, 03/06
4-110 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-111
inst_h3.fm
120 VAC, 60 Hz
Neutral ground
DANGER
7 This wire installation must be completed by a qualified electrician and must
comply with the national and local electrical codes.
Figure 4-63 HiPath 3750 - Grounding connector for Basic Cabinet (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
4-112 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Perform the tests in the table below to ensure that the system is properly grounded before star-
tup.
Prerequisites:
● HiPath 3750 is not yet connected to the low-voltage
network via the power cable.
● The system’s separate grounding is connected.
2. Check the ohmic resistance between the individual sys- < 1 ohm
tem parts (basic cabinet, expansion cabinets, main dis-
tribution frame).
Prerequisite:
HiPath 3750 is not yet connected to the low-voltage net-
work via the power cable.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-113
inst_h3.fm
All cables that leave the cabinet must be attached to the ventilation grill on the metal
> back panel using cable ties.
The “8-slot” basic cabinet has seven slots, while the expansion cabinets each have
> eight slots for peripheral boards.
X11
EC1
X5 X12
X13
EC2
X14
REAL
(BC
only)
X6 X88 X78 X68 X58 X48 X38 X28
X7
X89 X79 X69 X59 X49 X39 X29
P31003-H3560-S100-3-7620, 03/06
4-114 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
X100 X90 X80 X70 X60 X50 X40 X30 X20 X10
UPSM –
X13
BC
X14
Not
used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-115
inst_h3.fm
If Then
Two-cabinet Connect BC to EC1 = 2 cables (S30267-Z178-A13)
System (see Figure 4-66)
Three-cabinet ● Connect BC to EC1 = 2 cables (S30267-Z178-A13)
System ● Connect BC to EC2 = 2 cables (S30267-Z178-A13)
(see Figure 4-67)
P31003-H3560-S100-3-7620, 03/06
4-116 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Figure 4-66 Two-Cabinet “8-Slot” System - Connection Cables between BC and EC1
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-117
inst_h3.fm
EC2 BC X11
X13
X12
X13
X14
X14
Figure 4-67 Three-Cabinet “8-Slot” System - Connection Cables between BC, EC1 and
EC2
The cables between the basic cabinet and the expansion cabinets are connected in a star con-
figuration.
P31003-H3560-S100-3-7620, 03/06
4-118 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Introduction
Set up the connection between the main distribution frame and the system using CABLUs (pre-
fabricated cabling units) with the following characteristics:
● System side: SIPAC 1 SU connector(s)
● Cable: 16 x 2 x 0.4
● Main distribution frame side:
– Not for U.S.: Different distribution strips or carriers (Figure 4-70)
– For U.S. only: 50-pin CHAMP jacks
Not for U.S.: Not more than 9 CABLUs per MDFU (Figure 4-71) and 21 CABLUs per MDFU-E
(Figure 4-72) with one 16-TW strip or 25-TW strip (9 x 30 mm) strip can be implemented.
In special cases where the prefabricated CABLUs cannot be used, open-end cables should be
used.
Not for U.S.: CABLUs for the slots containing peripheral boards (Figure 4-88)
If Then
Assignment Route 16 TW to the MDFU or MDFU-E via SU Xx8 and 8 TW via SU Xx9,
with using a standard cable (with 16 TW) for each connection. Connect both ca-
SLMO81, bles (= 1 CABLU with SU connectors labeled 8 and 9) to the same jumper
SLMO24, strip (25 TW).
SLA8N1, Part numbers for CABLUs with 25-TW jumper strip:
SLA16N1 ● S30269-Z100-A14: 3 m in length, short stripped length for MDFU-E
or slots 11-21 (see Figure 4-72)
SLA24N ● S30269-Z100-A24: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-72)
Note: If replacing an old system, for example, you can use existing standard
CABLUs with splitting strips for 16 TW. If an SLMO24 board is used, you
must lay an additional CABLU (SU Xx9) to the MDFU or MDFU-E.
Assignment S2M connections are not set up via the MDFU or MDFU-E.
with A direct connection is set up to the NT or networked system via the back-
TMS2 plane connector SU Xx9 and a special cable (see Section 3.3.44, “TMS2
(Not for U.S.)”).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-119
inst_h3.fm
If Then
Slot with any Route 16 TW to the MDFU or MDFU-E via SU Xx8 using a CABLU.
other peripheral Part numbers for CABLUs with 16-TW jumper strips:
board ● S30269-Z100-A11: 3 m in length, short stripped length for MDFU-E
slots 11-21 (see Figure 4-72)
● S30269-Z100-A21: 3 m in length, long stripped length for MDFU-E
slots 1-10 (see Figure 4-72)
Assignment 16 TWs are routed to (and manually laid at) the MDFU or MDFU-E via
with SU X6 (backplane) using an open-end cable.
REAL Part numbers for open-end cable:
● S30267-Z192-A60: 6 m in length
● S30267-Z192-A100: 10 m in length
● S30267-Z192-A200: 20 m in length
1 A CABLU with 16 TW is also sufficient for these boards. A CABLU with 24 TW is recommended to simplify station config-
uration expansion (for example, by replacing the SLMO8 by an SLMO24).
For U.S. Only: CABLUs for the slots containing peripheral boards (Figure 4-88)
If Then
Slot with 24-port Route 16 TW to the main distribution frame via SU Xx8 and 8 TW via
peripheral board SU Xx9, using standard CABLU S30267-Z365-A30 (SU connectors are la-
beled “8” and “9”). Both cables are connected to the same 50-pin Champ
jack.
Slot with 16-port Route 16 TW to the main distribution frame via SU Xx8 using standard CA-
peripheral board BLU S30267-Z365-A30.
Slot with TMST1 T1 connections (see Section 3.3.43, “TMST1 (for U.S. only)”) are not set up
via the main distribution frame.
An adapter (1 SU connector - 8-pin MW8 (RJ48C) jack, Figure 4-68) is con-
nected directly to the SU Xx9 backplane connector. You can use a special
cable to create a direct connection to the CSU or networked system.
P31003-H3560-S100-3-7620, 03/06
4-120 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
MW8 (RJ48C
jack
SIPAC 1 SU
(to the NT, CSU
jack (Xx9
or networked
backplane)
system)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-121
inst_h3.fm
a 1 a
b
1
b
a 2 a
b 2
Connect the b
a 3 a
b 3
wires b
a 4 a
b 4
b
a 5 a
b 5
b
a 6 a
b 6 b
a 7 a
b 7 b
a 8 a
b 8 b
a a
9 9 b
b
a 10 a
10 b
b
a 11 a
11 b
b
a 12 a
12 b
b
a 13 a
b
13 b
View from below a
View from above (surge
a 14 14
b b protector plug locations)
a 15 a
b 15 b
a 16 a
b 16 b
Cable with film sheath: No. 6 (conductive copper tape) 1.5 windings. Ground
wire shortened to 25 mm and soldered onto conductive tape (1).
Stripped length
Stripped length = 600 ± 5 mm
250 ± 5
(1) Stripped length = 910 ± 5 mm for
MDFU-E slots 1 to 10
P31003-H3560-S100-3-7620, 03/06
4-122 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-123
inst_h3.fm
4.3.3.8 Laying the Line Network and Setting Jumpers on the MDFU or MDFU-E
Danger
7 Connect the system to ground before connecting the stations.
If you jumper stations on the MDFU or MDFU-E (for example, with an ICCS network)
> without first entering the relocate code, when you reconnect them the stations affect-
ed will go into operation with the data of the stations originally installed.
P31003-H3560-S100-3-7620, 03/06
4-124 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
a
b
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
a
b
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CABLU
S30269-Z100-A14: Cable 1 (SU Xx8) Cable 2 (SU Xx9) No. 25 not
used
a
b
1 3 5 7 9 11 13 15 17 19 21 23 25
Jumper strip for 25 TW (C39334-A166-A3)
Figure 4-70 Assignment (Numbering) of the Splitting/Jumper Strips, (view from above) (not
for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-125
inst_h3.fm
328.8
4
Jumpering
5 Channel
367.0
7 9 slots (9 x 30 mm)
Figure 4-71 MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.)
P31003-H3560-S100-3-7620, 03/06
4-126 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
328.8
4
Jumpering
5 Channel
6 21 slots (9 x 30 mm)
669.0
19
20
21
Special built-in
comps.
2 x PFT1
or
Figure 4-72 MDFU-E - Layout and Dimensions (669.0 x 328.8 x 125.4 mm) (not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-127
inst_h3.fm
DANGER
7 Ground the system properly before connecting the stations.
Caution
7 The TMST1 module can only be installed in conjunction with a listed channel service
unit (CSU).
Secondary Protection
DANGER
7 To protect against surge voltage caused by lightning, the following boards require
secondary protection when their lines leave the building where the main distribution
frame is housed:
● SLA16N / SLA24N
● TIEL4*
● TMDID8
● TMGL8
● TMST1**
* If not connected to facility provider terminal equipment.
** When this module is connected to the public network, secondary protection must
be provided by the CSU.
P31003-H3560-S100-3-7620, 03/06
4-128 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Overview
This section contains information on how to install the HiPath 3700 communication system in
a 19-inch cabinet. This chapter describes the standard installation procedures for the basic sys-
tem. Refer to Chapter 9 for information about supplementary equipment and expansions.
Information on
● the possible equipment of central boards with optional plug-in boards
● board configuration
● final visual inspection
applies to both HiPath 3700 and HiPath 3750 and is described starting in Section 4.3.5.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-129
inst_h3.fm
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
P31003-H3560-S100-3-7620, 03/06
4-130 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
WARNING
7 A fully equipped HiPath 3700 cabinet weighs 22 kg (48.46 lb). We recommend lifting
cabinets only before they are equipped. Do not attempt to lift objects that you think
are too heavy for you; use a hand truck or get assistance.
Introduction
You can install up to three system cabinets in a 19-inch cabinet. Each cabinet must be mounted
separately.
It is only possible to extend the HiPath 3700 to a three cabinet system if the 19-inch cabinets
are next to one another and accessible from the back.
Cabinets are supplied fitted with the specific boards required by the customer.
Danger
7 Be sure to ground the system properly before starting it up and connecting the sta-
tions.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-131
inst_h3.fm
Step Activity
1. Insert a slotted screwdriver (with the blade vertical) into a recess (1).
2. Carefully swing the handle of the screwdriver toward the center of the cabinet (2)
until the fastener snaps out and the cover loosens.
3. Then insert the screwdriver in the second recess (3), loosen its snap fastener.
Cabinet
(3)
(1)
(2)
Figure 4-73 HiPath 3700 - Removing the Front and Rear Covers
Warning
7 The front and rear covers on all system cabinets must be closed before the system
is started up in a 19-inch cabinet.
To replace a cover, position the snap fasteners in the two guides and press down on
the cover until it snaps into place.
P31003-H3560-S100-3-7620, 03/06
4-132 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Procedure
Warning
7 Never attempt to lift a system cabinet into the 19-inch cabinet without assistance.
Step Activity
1. Attach a right-handed and a left-handed support bracket (A in Figure 4-74) to the
19-inch cabinet using two screws per bracket.
2. Remove the front and rear cabinet covers.
3. Remove both side pieces of the system cabinet.
4. Attach the two angle brackets (B in Figure 4-74) to the front of the system cabinet
using two screws per bracket.
5. Attach the four angle brackets (C in Figure 4-74) to the rear of the system cabinet
for base and cover support.
6. Lift the system cabinet into the 19-inch cabinet and sit the cabinet on the two sup-
port brackets (A). Slide the cabinet into the 19-inch cabinet until the front edge of
the system cabinet is flush with the front of the 19-inch frame.
7. Attach the system cabinet to the angle bracket (B) in the 19-inch cabinet frame
using two screws per bracket.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-133
inst_h3.fm
B
C
Caution
7 Be careful when breaking out the recesses. Remove any sharp edges and corners.
P31003-H3560-S100-3-7620, 03/06
4-134 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Installation Procedure
Install the patch panel immediately under the system cabinet (A in Figure 4-75) and attach it to
the left and right of the 19-inch frame using two screws (B) on each side.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-135
inst_h3.fm
YES
Does the 19-inch cabinet have NO A potential equalization bus must be installed in
a potential equalization bus at the 19-inch cabinet and connected to the ground
which the HiPath 3700 can be conductor.
grounded as shown in Figure 4- Danger
76? If your personnel are not qualified to work on the
low-voltage network (230 Vac), you must hire a li-
censed electrician to install the ground.
YES
If you answer “Yes” to both questions, the system (system cabinets, patch panels) may be
grounded as described below.
Danger
7 Each HiPath 3700 system cabinet and each patch panel (S30807-K6143-X) must be
grounded as shown in Figure 4-76 by a separate ground conductor (minimum cross-
section = 2.5 mm2). Make sure that the ground conductor is securely installed and
strain-relieved.
Please note:
The 19-inch cabinet’s potential equalization bus may only be used if it is grounded
by a separate ground conductor.
Failure to follow these instructions can result in electrical shock.
P31003-H3560-S100-3-7620, 03/06
4-136 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
HiPath 3700, BC
Patch Panel
S30807-K6143-X
Figure 4-76 HiPath 3700- Grounding the Systems and Patch Panels in a 19-Inch Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-137
inst_h3.fm
To avoid ground loops from remotely operated devices (V.24 system peripherals),
> the devices should be connected to the same low-voltage network (sub-distribution
board) if possible.
If the building floor plan does not permit this, you may need a line driver to isolate
the external devices in the event of a malfunction.
Procedure
Perform the tests in the table below to ensure that the system is properly grounded before star-
tup.
Prerequisites:
● No device in the 19-inch cabinet is connected to the
low-voltage network via the power cable.
● The system’s separate grounding (basic cabinet, ex-
pansion cabinet, patch panel) and the grounding of
the 19-inch cabinet are connected.
2. Check the ohmic resistance between the individual sys- < 1 ohm
tem parts (basic cabinet, expansion cabinets, patch pan-
els).
Prerequisite:
HiPath 3700 is not yet connected to the low-voltage net-
work via the power cable.
P31003-H3560-S100-3-7620, 03/06
4-138 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
All cables that leave the cabinet must be attached to the ventilation grill on the metal
> back panel using cable ties.
The “8-slot” basic cabinet has seven slots, while the expansion cabinets each have
> eight slots for peripheral boards.
X11
EC1
X5 X12
X13
EC2
X14
REAL
(BC
only)
X6 X88 X78 X68 X58 X48 X38 X28
X7
X89 X79 X69 X59 X49 X39 X29
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-139
inst_h3.fm
X100 X90 X80 X70 X60 X50 X40 X30 X20 X10
UPSM –
X13
BC
X14
Not
used
P31003-H3560-S100-3-7620, 03/06
4-140 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
If Then
Two-cabinet Connect BC to EC1 = 2 cables (S30267-Z178-A13)
System (see Figure 4-79)
Three-cabi- ● Connect BC to EC1 = 2 cables (S30267-Z178-A13)
net ● Connect BC to EC2 = 2 cables (S30267-Z178-A13)
System (see Figure 4-80)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-141
inst_h3.fm
Figure 4-79 Two-Cabinet “8-Slot” System - Connection Cables between BC and EC1
P31003-H3560-S100-3-7620, 03/06
4-142 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
EC2 BC X11
X13
X12
X13
X14
X14
Figure 4-80 Three-Cabinet “8-Slot” System - Connection Cables between BC, EC1 and
EC2
The cables between the basic cabinet and the expansion cabinets are connected in a star con-
figuration.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-143
inst_h3.fm
4.3.4.7.2 Connecting the Patch Panel and Backplane (in the 19-Inch Cabinet)
Introduction
Set up the connection between the patch panel and system using CABLUs (prefabricated ca-
bling units) with the following characteristics:
● System side: SIPAC 1 SU jack
● Cable: 16 x 2 x 0.4 (the standard cable length is 2 m)
● Patch panel side:
– Not for U.S.: Open-end cable (for STMD8) or SIVAPAC socket connectors (for all other
boards)
– For U.S. only: ---
Not for U.S.: CABLUs for the slots containing peripheral boards
If Then
Assignment Route 16 TW to the patch panel (S30807-K6143-X) via SU Xx8 and 8 TW via
with SU Xx9 using a standard cable (with 16 TW) for each connection. Connect
SLMO81, both cables (= 1 CABLU with SU jacks labeled 8 and 9) to the same SIVAPAC
SLMO24, socket terminal strip (25 TW).
SLA8N1, Part number for CABLU with 24 TW:
SLA16N1 ● S30267-Z363-A20: 2 m in length
or
SLA24N
Assignment You need a special S0 patch panel (C39104-Z7001-B3) for this. The 16 TW
with are routed to (and manually laid at) the S0 patch panel via SU Xx8 (back-
STMD8 plane) using an open-end cable.
Part numbers for open-end cable:
● S30267-Z192-A60: 6 m in length
● S30267-Z192-A100: 10 m in length
● S30267-Z192-A200: 20 m in length
Assignment S2M connections are not set up via a patch panel.
with An adapter (SIPAC 1 SU jack - 8-pin MW8 (RJ48C) jack, Figure 4-86) is con-
TMS2 nected directly to the SU Xx9 backplane connector. You can use a special ca-
ble (see Section 3.3.44, “TMS2 (Not for U.S.)”) to create a direct connection
to the NT or networked system.
P31003-H3560-S100-3-7620, 03/06
4-144 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
If Then
Slot with any Route 16 TW to the patch panel (S30807-K6143-X) via SU Xx8 using a CA-
other periph- BLU.
eral board Part number for CABLU with 16 TW:
● S30267-Z362-A20: 2 m in length
Assignment Route the REAL board via an S0 patch panel (C39104-Z7001-B3). The 16 TW
with are routed to (and manually laid at) the S0 patch panel via SU X6 (backplane)
REAL using an open-end cable.
Part numbers for open-end cable:
● S30267-Z192-A60: 6 m in length
● S30267-Z192-A100: 10 m in length
● S30267-Z192-A200: 20 m in length
1 A CABLU with 16 TW is also sufficient for these boards. A CABLU with 24 TW is recommended to simplify station config-
uration expansion (for example, by replacing the SLMO8 by an SLMO24).
For U.S. only: CABLUs for the slots containing peripheral boards
If Then
Slot with 24-port Route 16 TW to the patch panel via SU Xx8 and 8 TW via SU Xx9, using
peripheral standard CABLU S30267-Z365-A30 (SU connectors are labeled “8” and
boards “9”). Both cables are connected to the same 50-pin Champ jack.
Slot with 16-port Route 16 TW to the main distribution frame via SU Xx8 using standard CA-
peripheral BLU S30267-Z365-A30.
boards
Slot with TMST1 T1 connections (see Section 3.3.43, “TMST1 (for U.S. only)”) are not set up
via the main distribution frame.
An adapter (1 SU connector - 8-pin MW8 (RJ48C) jack, Figure 4-86) is con-
nected directly to the SU Xx9 backplane connector. You can use a special
cable to create a direct connection to the CSU or networked system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-145
inst_h3.fm
All incoming cables must be attached to the patch panel using cable ties.
>
SIVAPAC edge connector: port for
CABLU connection to the backplane
Surge protector
To divert surges caused by lightning, insert surge protectors on
● lines that leave the system buildings (outside stations)
● lines > 500 m long.
Connect the polarized surge protectors to slots F1 – F8 provided on the patch panel
(seeFigure 4-82).
P31003-H3560-S100-3-7620, 03/06
4-146 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
X5 X1
X11
1 X12 1 X9 X9, X10, X11 and PFT1 not
1 X13 1 X10 used in HiPath 3000.
1 X14
1 X15
F1 F4 F6 F8 Slots F1–F8 for PFT1
surge protector
F2 F3 F5 F7
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 2 3 4 5 6 7 8 X12, X14
1 2 3 4 5 6 7 8
X13, X15
1 2 3 4 5 6 7 8
a b a b a b a b a b a b a b a b
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-147
inst_h3.fm
All incoming cables must be attached to the patch panel using cable ties.
>
24 22 20 18 ... ... 8 6 4 2
23 21 19 17 ... ... 7 5 3 1
P31003-H3560-S100-3-7620, 03/06
4-148 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
87632145
Pin assignment of MW8 jacks
Twist the wire pairs before laying them.
Figure 4-84 Laying Wire Pairs at the S0 Patch Panel
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-149
inst_h3.fm
Stripped length
250 ± 5
(1)
Cable with film sheath: No. 6 (conductive copper tape) 1.5 windings. Ground wire
shortened to 25 mm and soldered onto conductive tape (1).
Stripped length = 600 mm ± 5 mm
Color Pair a-Wire b-Wire Color Pair a-Wire b-Wire Color Pair a-Wire b-Wire
group (Tip) (Ring) group (Tip) (Ring) group (Tip) (Ring)
1 1 wht/blu 2 6 red/blu 3 11 blk/blu
blu/wht blu/red blu/blk
2 wht/ora 7 red/ora 12 blk/ora
ora/wht ora/red ora/blk
3 wht/grn 8 red/grn 13 blk/grn
grn/wht grn/red grn/blk
4 wht/brn 9 red/brn 14 blk/brn
brn/wht brn/red brn/blk
5 wht/gry 10 red/gry 15 blk/gry
gry/wht gry/red gry/blk
4 16 yel/blu
blu/yel
Figure 4-85 Stripping the Open-End Cable for the S0 Patch Panel
P31003-H3560-S100-3-7620, 03/06
4-150 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
MW8 (RJ48C
jack
SIPAC 1 SU
(to the NT, CSU
jack (Xx9
or networked
backplane)
system)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-151
inst_h3.fm
Danger
7 Connect the system to ground before connecting the stations.
Telephones and trunks are connected directly to the MW8 jacks on the front of the patch panel.
Information on MW8 jack assignment on the front of the patch panel is provided in the board
descriptions (in the “Cable and Connector Assignment” table) in Chapter 3.
If you jumper stations on the patch panel (for example, with an ICCS network) with-
> out first entering the relocate code, when you reconnect them the stations affected
will go into operation with the data of the stations originally installed.
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
Figure 4-87 Layout of the Patch Panel S30807-K6143-X for Different Peripheral Boards
P31003-H3560-S100-3-7620, 03/06
4-152 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards). Connect the wristband to the slide-in shelf in the cabinet using the
alligator clip.
The cabinets are already equipped with the boards needed for the customer-specific require-
ments when the system is delivered.
The central control boards are not always fully equipped when delivered. Optional plug-in
boards are packaged individually.
See Chapter 3 for information on slots for subboards on the central control boards.
Caution
7 Place the central control board on a flat surface before installing subboards.
The spacing bolts supplied guarantee the correct insertion of the subboard, so you
should always mount them (see Figure 3-6).
Otherwise you may damage the board.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-153
inst_h3.fm
Introduction
The cabinet/cabinets is/are already equipped with the boards needed for the customer-specific
requirements when the system is delivered.
P31003-H3560-S100-3-7620, 03/06
4-154 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Slot no.,
EC1: 10 11 12 13 14 15 16 17 UPSM
EC2: 19 20 21 22 23 24 25 26 UPSM
Slot width
(mm): 30 30 30 30 30 30 30 30 90
Figure 4-88 Slot Numbers and Widths in “8-Slot” BC, EC1, and EC2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-155
inst_h3.fm
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards).
P31003-H3560-S100-3-7620, 03/06
4-156 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Expansion
Expansion cabinet1
cabinet
U
U
P
P
S
S
M
M
BC
BC Expansion
Expansion cabinet
cabinet 2
C
C U
U U
U
B
B P
P P
P
C
C S
S S
S
P
P M
M M
M
R
R
Figure 4-89 HiPath 3750 and HiPath 3700 - Initialization of Subscriber Line Circuits and
Ports
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-157
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-158 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
Caution
7 The following board assignment rules must be observed to ensure that the system
works properly and without blocking:
● SLC16N
– Maximum SLC16N per PCM segment. The SLC16N should be configured
alone on the PCM segment, where possible.
– Note the following information on the subject of multi-SLCs: “SLC16N board
distribution in HiPath 3750 and HiPath 3700 cabinets” on page 3-157.
● IVML8, IVML24 (see Section 3.3.6)
– A maximum of one IVML8 or IVML24 per system.
– Then install them in the slot beside the power supply in the basic cabinet or
the expansion cabinets.
– No SLC16N may be inserted in the PCM segment of the IVML8/IVML24.
– No SLMO24 may be inserted in the PCM segment of the IVML24.
– If a TMS2 is configured on the PCM segment of the IVML24, only a board
with a maximum of 8 ports may be inserted in the free slot.
● SLMO24
A maximum of two SLMO24s per PCM segment; the number of connected sta-
tions (hosts (master) and clients (slaves)) may not be more than 64.
The figures below show the PCM segments (64 time-division multiplex channels each) for the
different HiPath 3750 and HiPath 3700 system configurations.
“8-slot” cabinets
C 000000 0 U
B 234567 8 P
C S
P M
R
BC
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-159
inst_h3.fm
“8-slot” cabinets
C 000000 0 U 1 111111 1 U
B 234567 8 P 0 123456 7 P
C S S
P M M
R
BC EC1
“8-slot” cabinets
1 111111 1 U
0 123456 7 P
S
M
EC1
C 000000 0 U 1 222222 2 U
B 234567 8 P 9 012345 6 P
C S S
P M M
R
BC EC2
P31003-H3560-S100-3-7620, 03/06
4-160 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
HiPath 3750 Slots per PCM seg- Static traffic capac- Total static traffic
HiPath 3700 ment ity per PCM seg- capacity of the
ment system
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-161
inst_h3.fm
Introduction
Peripheral boards can be inserted and removed while the power is connected. Two levers are
attached to the front corners of the boards to simplify insertion and removal. When closed,
these levers engage with the board, locking it in place.
See Section 9.2.2 for information on upgrading peripheral boards.
If Then
Boards Swing both plastic levers outward simultaneously. You can now pull the board
Unlocking the out of the system on its guide rails.
board
(1)
Boards Slide the board into the system using its guide rails. Insert the hooks on the
Latching as- locking levers into the recesses in the shelf. Press down on both levers simul-
sembly taneously in the direction of the shelf until they snap into place.
(2)
(1)
(2)
(2)
(1)
P31003-H3560-S100-3-7620, 03/06
4-162 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3750, HiPath 3700
The special REAL board is mounted on the metal back panel (basic cabinet only) and connect-
ed to the backplane with a ribbon cable.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-163
inst_h3.fm
Introduction
Before starting up the system, you must perform a visual inspection of the hardware, cables,
and the power supply. The procedure is shown in Table 4-18. The visual inspection must be
performed while the system is disconnected from the power supply.
Caution
7 Before beginning work, make sure that the system is grounded and disconnected
from the power supply.
Observe the measures for protecting electrostatically sensitive devices (see Page 1-
9).
After finishing the visual inspection, you can begin starting up the HiPath 3750 or Hi-
> Path 3700 system as described in Chapter 5.
P31003-H3560-S100-3-7620, 03/06
4-164 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.4 Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Warning
7 Only authorized service personnel should install and start up the system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-165
inst_h3.fm
Table 4-19 HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 - System Installation
Procedure
P31003-H3560-S100-3-7620, 03/06
4-166 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Selecting a site
The customer usually has a preferred installation site in mind.
Make sure that the customer’s site meets the following guidelines:
● To guarantee sufficient system ventilation, keep the area surrounding the housing clear as
follows: allow 30 cm clearance on the left (for board replacement), and 10 cm clearance on
the right, top and bottom of the housing.
● Do not expose the systems to direct sources of heat (for example sunlight and heaters).
● Do not expose the systems to extremely dusty environments.
● Avoid contact with chemicals.
● Take every precaution to prevent the formation of condensation on the system during op-
eration. Systems covered with condensation must be dried before being used.
● Observe the environmental conditions specified in Section 2.11.
For U.S. Only:
● Ensure that the installation site is in the immediate vicinity of an electrical outlet
● Allow space for a main distribution frame or other additional equipment.
● Install lightning and surge arrester equipment.
● Avoid standard carpeting, as it tends to produce electrostatic charges.
● Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The
National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical
equipment and 40 in. (101.6 cm) of clearance from other electrical service equipment.
● Ensure that the equipment room for the system provides adequate space for installation
and maintenance activities, including removing and replacing the cover). See Figure 4-94
for space requirements on the sides of the system. We recommend using a plywood back-
board at least 0.5 in. (127 mm) thick and measuring at least 4 ft. (122 cm) by 4 ft. (122 cm.).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-167
inst_h3.fm
Leave 46 cm 20.3 cm
(18’’) free HiPath 3550 (8’’)
or
HiPath 3350
Backplane
50.8 cm
122 X 122 cm (4 X 4 ft.)
(20’’)
The system measures 18 by 17.7 inches (46 x 45 cm). The following spaces
should be allowed: 18 in. (46 mm) of clearance on the left, and at least 8 in. (203
mm) of clearance on the top and right. Allow 20 in. (50.8 cm) of clearance on the
bottom (for cables).
Figure 4-94 HiPath 3550 and HiPath 3350 - Space Requirements (for U.S. only)
P31003-H3560-S100-3-7620, 03/06
4-168 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
You will find information on the design and dimensions in the following section:
● HiPath 3550 Section 2.2.2.3
● HiPath 3350 Section 2.2.2.4
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-169
inst_h3.fm
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
4.4.3.3 Not for U.S.: Mounting the Main Distribution Frame (HiPath 3550 only)
Introduction
MDFU is the main distribution frame used (see Figure 4-95).
Installation notes
The MDFU-E main distribution frame should be installed in the direct vicinity of the system
(note length of connection cable) and at eye level. Mount it on the wall according to the instruc-
tions that came with it. The bag attached to the cover contains a drill template. It also contains
the necessary screws and wall anchors for attaching the MDF to the wall.
The MDFU must be grounded. Refer to Section 4.4.3.6 for an explanation of the procedure.
P31003-H3560-S100-3-7620, 03/06
4-170 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Step Activity
1. Use the template to drill the holes.
2. Insert the wall anchors and screw in the screws, leaving 5 mm projecting.
3. Remove the housing cover and mount the MDFU-E on the brackets.
4. Tighten the screws through the holes.
328.8
4
Jumpering
5 Channel
367.0
7 9 slots (9 x 30 mm)
Figure 4-95 MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-171
inst_h3.fm
Warning
7 To prevent injuries, you must observe the following instructions for the removal and
attachment of the HiPath 3550 and HiPath 3350 housing cover.
Procedure
Step Activity
1. Loosen the two screwed plugs on the housing cover with a slotted screw driver.
Hold the housing cover so that it does not fall.
P31003-H3560-S100-3-7620, 03/06
4-172 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Step Activity
2. Remove the housing cover.
Warning
Grasp the housing cover by its outside walls only.
The shielding plate on the inside of the cover may have sharp edges which can
cause cuts.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-173
inst_h3.fm
Attaching the HiPath 3550 and HiPath 3350 housing to the wall
30 cm
P31003-H3560-S100-3-7620, 03/06
4-174 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Because of their safety class, the HiPath 3550 and HiPath 3350 do not have to be
> grounded.
If grounding is required in certain countries (for example in Finland, Norway, U.S.),
the wall housing HiPath 3550 and HiPath 3350 must be grounded by a separate
ground conductor via the ground connection marked “ ”.
For U.S. and Canada only: Grounding the system
The connector cables of systems HiPath 3550 and HiPath 3350 have a grounding. The system
must also be grounded by a separate ground conductor. This grounding connection must meet
the requirements of the relevant authorities (U.S. National Electrical Code, Canadian Electrical
Code). Lay a separate grounding from the earth to the system’s grounding connector. The
cross-section of the grounding must measure at least 14 AWG.
Grounding for the external main distributor frame
● Not for U.S.:
– HiPath 3550: Shipments always include an MDFU (Germany only) and two grounding
cables. Use one of the cables to ground the MDFU. It is not necessary to ground the
connection between the MDFU and HiPath 3550 (see Figure 4-98).
– HiPath 3350: This system type does not require an external main distribution frame.
The connection cables to the peripherals are attached directly to the boards and rout-
ed to the outside via a cable duct inside the housing.
Danger
7 An external main distribution frame which requires grounding (if the existing
ground connection is marked “ ”) must be grounded by a separate ground
conductor (minimum cross-section = 2.5 mm2)
Failure to follow these instructions can result in electrical shock.
Refer to Figure 4-98 when replacing a customer system but maintaining the existing exter-
nal main distribution frame.
● For U.S. only:
The customer supplies a main distribution frame to complete the communications system.
Mount and ground the MDF in accordance with the manufacturer’s instructions.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-175
inst_h3.fm
S
Y
S
T
E Grounding
M screw
green/yellow
Min. cross-section = 2.5 mm2
Figure 4-98 HiPath 3550, HiPath 3350 - Grounding an External Main Distribution Frame
P31003-H3560-S100-3-7620, 03/06
4-176 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Caution
7 The TST1 Module (HiPath 3550) can be installed only in conjunction with a listed
channel service unit (CSU).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-177
inst_h3.fm
HiPath 3550 and HiPath 3350 - CABLU for connection to the external main distribution
frame
P31003-H3560-S100-3-7620, 03/06
4-178 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
HiPath 3550 - MDFU ports for peripheral boards in HiPath 3750 format
Figure 4-100 HiPath 3550 - Backplane Connection for a Peripheral Board in HiPath 3750
Format
If Then
SLA8N Route the 16 TW to the MDFU via the SU X8 and 8 TW via SU X9 (see
SLA16N Figure 4-100) using a standard cable (with 16 TW). Connect both cables (= 1
SLA24N CABLU with SU connectors labeled 8 and 9) to the same jumper strip (25
SLC16N TW).
SLMO24
Slot with any ● Without an external main distribution frame (MDFU):
other periph- You can attach cables for the peripheral boards directly to the boards (see
eral board Figure 4-101 for the slip-on connectors) and route them to the MDFU
through the cable duct inside the housing.
● With an external main distribution frame (MDFU):
Use CABLU S30269-Z41-A30 (Figure 4-99) to connect the peripheral
boards to the customer’s line network. As shown in Figure 4-101, you can
connect the eight-pin slip-on connectors to the boards directly. The line
network connects directly to the jumper strip.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-179
inst_h3.fm
Plug connection
to the
HiPath
Screw con- 3550andHiPath
nections to 3350
the network
For U.S. only: HiPath 3550 and HiPath 3350: Connecting the Cabling
If the boards are not already connected to the appropriate cables leaving the system, you need
to connect them.
● The TST1 Module (HiPath 3550) connects to a customer-supplied channel service unit
(CSU) using the supplied cable. The CSU provides the required secondary protection.
● Each port on the STLS4 Module connects to an S0 bus using the supplied, silver-satin con-
nector cord and a surface-mounted RJ21X jack. The surface-mounted RJ21X jack is not
supplied.
The signals must be reversed in the RJ45X jack. See Figure 3-85.
● The board in Slot 10 of HiPath 3550 connects using a special cable from the backplane to
the main distribution frame (MDF).
● The remaining peripheral boards and options are connected by means of a mains distrib-
utor provided on the customer side or a comparable unit. This is where the MDF cables
supplied are used (Octopus cable with Amphenol terminators). You select the output pat-
tern on the Amphenol connector by which slip-on connector you use on each board edge
connector.
P31003-H3560-S100-3-7620, 03/06
4-180 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
● Note: The MDF cable reverses the signals coming from the board. This means that R/T on
the board interface becomes T/R on the Amphenol connector.
40 +/– 5 mm min. 15 mm
Ferrite sleeve
C39022-Z7000-C7
Power cable
Figure 4-102 HiPath 3550 and HiPath 3350 - Power Cable with Ferrite Sleeve
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-181
inst_h3.fm
Digital and analog trunks and subscriber lines from HiPath 3550 (wall housing)
The accessory pack does not contain enough ferrite sleeves for all trunks and sub-
> scriber lines possible in a maximum system configuration. In this case, you will need
to order additional ferrite.
If Then
Trunk board or Guide both standard cables from SU X8 and SU X9 (see Figure 4-100) to
subscriber line the MDFU through two ferrite sleeves (C39022-Z7000-C7) each. The ferrite
modules in Hi- should be placed as far inside the housing as possible.
Path 3750 for-
mat
Trunk or sub- Guide the trunk and subscriber lines of all ports connected on a board
scriber line through a ferrite sleeve twice, i.e. in a loop. The ferrite should be fixed in the
modules in cable duct if possible. If the number of lines makes this impossible, the ferrite
“small” format can be attached directly at the output of the cable duct.
P31003-H3560-S100-3-7620, 03/06
4-182 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Restrictions for equipment with IVMP8, IVMS8, TST1 and TS2 boards must be ob-
> served.
PSU
UPS
Cable
duct
1
2
3 Optional boards
4
Slot levels 5 CUC
6
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-183
inst_h3.fm
Opt.1
Slot 2
Slot 4
Slot 8
Slot 6
Opt.2
Slot 10 (HiPath 3750
Wall
CBCC
Opt.3
Opt.4
Slot 3
Slot 5
Slot 7
Slot 9
Opt.5
to MDF
V.24
1 2 3 4 5 6
Slot levels
Figure 4-104 HiPath 3550 - Slots in the Wall Housing
P31003-H3560-S100-3-7620, 03/06
4-184 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
PSU
UPS
Cable
duct
1 Optional boards
2
3
Slot levels CUP
OPAL
Opt.1
Slot 4
Slot 2
Opt.2
CBCC
Wall
Opt.3
Opt.4
Slot 5
Slot 3
Opt.5
V.24
1 2 3
Slot levels
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-185
inst_h3.fm
P31003-H3560-S100-3-7620, 03/06
4-186 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Caution
7 Conduct the visual inspection only while the system is disconnected from the power
supply.
Always wear an antistatic wristband and observe the measures for protecting elec-
trostatically sensitive devices (see Page 1-9).
After finishing the visual inspection, you can begin starting up the system as de-
> scribed in Chapter 5.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-187
inst_h3.fm
Danger
7 The HiPath 3500 and HiPath 3300 systems can only be operated with a closed hous-
ing.
Before opening the housing, make sure that the system is de-energized as follows:
● Disconnect the line cord on any connected battery pack (for UPSC-DR only).
● Disconnect the line cord on any connected EPSU2-R (for UPSC-DR only).
● Disconnect the power plug.
P31003-H3560-S100-3-7620, 03/06
4-188 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Selecting a site
The customer usually has a preferred installation site in mind, for example an existing 19-inch
cabinet.
Make sure that the customer’s site meets the following guidelines:
● To guarantee sufficient system ventilation, allow a minimum of 10 cm clearance around the
housing.
● Do not expose the systems to direct sources of heat (for example sunlight and heaters).
● Do not expose the systems to extremely dusty environments.
● Avoid contact with chemicals.
● Take every precaution to prevent the formation of condensation on the system during op-
eration. Systems covered with condensation must be dried before being used.
● Observe the environmental conditions specified in Section 2.11.
You will find information on the design and dimensions in the following section:
● HiPath 3500 Section 2.2.2.6
● HiPath 3300 Section 2.2.2.7
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-189
inst_h3.fm
Procedure
Step Activity
1. Compare the components with the packing slip or customer receipt to make sure
that they are correct and complete.
2. Determine whether any damage has occurred during transport and report it to the
proper departments.
3. Dispose of the packing materials properly.
Caution
7 Only use tools and equipment that are in perfect condition. Do not use equipment
with visible damage.
P31003-H3560-S100-3-7620, 03/06
4-190 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
4.4.4.4 Not for U.S.: Attaching a HiPath 3500 and HiPath 3300 to the Wall
Step Activity
1. Drill a hole in the selected wall, insert a wall anchor and screw in the screws.
2. Screw the angle brackets (A) and (B) for HiPath 3500 or HiPath 3300 onto the
base of the device.
3. Mount the system with the angle bracket (A) on the screws.
4. Drill a second hole in the wall for the lower angle bracket (B), insert a wall anchor
and attach the angle bracket with a screw.
Wall mounting
HiPath 3500 /
HiPath 3300
B
Figure 4-108 HiPath 3500 and HiPath 3300 - Wall Installation (for U.S.)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-191
inst_h3.fm
Step Activity
1. HiPath 3500 only: Attach the two angle brackets (A) to the 19-inch cabinet using
two screws per bracket.
2. Attach the two angle brackets (B) to the left and right of the HiPath 3500 or HiPath
3300 using two screws per bracket.
3. Slide the HiPath 3500 or HiPath 3300 system into the 19-inch cabinet and attach
it to the left and right of the 19-inch frame with screws.
P31003-H3560-S100-3-7620, 03/06
4-192 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
B
B
HiPath 3500
Figure 4-109 HiPath 3500 and HiPath 3300 - Mounting the 19-Inch Cabinet
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-193
inst_h3.fm
YES
Does the 19-inch cabinet have NO A potential equalization bus must be installed in
a potential equalization bus at the 19-inch cabinet and connected to the ground
which the HiPath 3500 or Hi- conductor.
Path 3300 can be grounded? Danger
If your personnel are not qualified to work on the
low-voltage network (230 Vac), you must hire a li-
censed electrician to install the ground.
YES
If you answer “Yes” to both questions, the HiPath 3500 or HiPath 3300 systems may be
grounded as described below.
P31003-H3560-S100-3-7620, 03/06
4-194 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Step Activity
1. Connect the grounding cable to the potential equalization bar on the 19-inch cab-
inet.
2. Connect the grounding cable to the system’s ground connection with the ground-
ing screw supplied (point A).
3. Attach the grounding cable (strain relief) to the system (point B) with a cable tie.
A
Grounding cable B
Danger
7 The HiPath 3500 and HiPath 3300 housing to be wall-mounted must be grounded by
a separate ground conductor (such as a potential equalization bar). Make sure that
the ground conductor is securely installed and strain-relieved.
Failure to follow these instructions can result in electrical shock.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-195
inst_h3.fm
Not for U.S. and Canada Connection cable for the expansion cabinet rack ECR (if
present)
To meet EMC requirements, the braided shields on the connection cable must be connected to
the housing on the HiPath 3500 or HiPath 3300 side and on the ECR side.
● Attaching to the HiPath 3500 or HiPath 3300 side
A clip and a tooth lock washer are enclosed with the ECR mounting set. Use these and the
housing cover mounting screw to attach the braided shield to the HiPath 3500 or HiPath
3300 housing (as shown in Figure 4-111). The tooth lock washer must be mounted be-
tween the painted surface of the cover and the clip.
Clip
Housing cover
Figure 4-111 HiPath 3500 and HiPath 3300 - Connection Cable to ECR
● Attaching to the ECR side (see Page 9-9)
Line network
The connecting cords to the peripherals can be connected directly to the relevant MW8 jacks
on the front panel of the 19-inch housing.
P31003-H3560-S100-3-7620, 03/06
4-196 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
Caution
7 For safety, operate HiPath 3500 only with the housing front closed. Always use dum-
my panels (C39165-A7027-B115) to close slots that are not equipped with boards.
Slot
levels:
5 (options)
Slots 1-3
4 (CBRC)
Slot 6 Slot 7 3 (Peripheralboards)
Slot 8 Slot 9 2 (Peripheralboards)
Slot 4 Slot 5 1 (Peripheralboards)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-197
inst_h3.fm
Caution
7 For safety, operate HiPath 3300 only with the housing front closed. Always use dum-
my panels (C39165-A7027-B115) to close slots that are not equipped with boards.
Slot
levels:
3 (options)
Slots 1-3
2 (CBRC)
Slot 4 Slot 5 1 (Peripheralboards)
P31003-H3560-S100-3-7620, 03/06
4-198 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
inst_h3.fm
Installing HiPath 3000
Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 4-199
inst_h3.fm
Caution
7 Conduct the visual inspection only while the system is disconnected from the power
supply.
Always wear an antistatic wristband and observe the measures for protecting elec-
trostatically sensitive devices (see Page 1-9).
After finishing the visual inspection, you can begin starting up the system as de-
> scribed in Chapter 5.
P31003-H3560-S100-3-7620, 03/06
4-200 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Overview
5.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Starting Up HiPath 3800, page 5-2
Starting Up HiPath 3750 and HiPath 3700, page 5-11
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300, page 5-19
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-1
start_h3.fm
Warning
7 Only authorized service personnel should start up the system.
Danger
7 The system may only be started (connected to the power supply) if all system cabi-
nets are sealed at the rear with the connection and filler panels provided.
P31003-H3560-S100-3-7620, 03/06
5-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3800
Procedure
Step Activity
1. Plug in the power supply cable for the system cabinet(s).
2. Position all LUNA2 power supply switches to “DC-ON”.
Note: Startup does not begin until the switches on all LUNA2 units are in “DC-ON”
position.
3. Monitor the RUN LED of the CBSAP. The individual steps of the system boot
(Table 5-2) can be observed this way.
The HiPath 3800 is ready when the date “1. JAN 00” and the time “00:00” appear in
> the display on the system telephone.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-3
start_h3.fm
If Then
Missing or defective board No action.
Different board type The system does not automatically activate the board.
Underequipped or same Board is activated. The same station range is used.
board variant
Over-equipped board variant Board is activated. The old station range is activated and the
ports associated with the new board are inserted at the end.
The ports are split if there is no contiguous station range avail-
able.
New board in empty slot ● Board was the last one installed in accordance with the
placement sequence:
All boards are activated and the numbering plan continues
without a gap.
● Board was inserted ahead of another board in the place-
ment sequence:
Board is activated and appended to the last board in the
numbering plan.
P31003-H3560-S100-3-7620, 03/06
5-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3800
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of the
numbering plan:
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-5
start_h3.fm
Procedure
The reset/reload switch is tested by a Field Programmable Gate Array (FPGA). This
> FPGA is loaded by the processor when starting up the HiPath 3800 and is only fully
functional after the loading process is complete. If the reset/reload switch is activated
during loading, then it is not possible to evaluate the cause of the restart. For this
reason, the reset/reload switch may only be activated after the system startup (green
Run LED lights up).
Press and hold down the reset switch for at least 5 seconds (FAIL LED (red) goes out). If you
do not hold down the reset switch for a full 5 seconds, the system may perform a reset rather
than a reload or may not reload properly.
P31003-H3560-S100-3-7620, 03/06
5-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3800
Since the system software no longer provides all languages, some systems no long-
> er start up in the customary local language after the country code is entered. You
must now load the local language prior to country initialization, using HiPath 3000
Manager E (see information on multilingual text output in the Feature Description Hi-
Path 3000/5000).
After carrying out the country initialization, but before loading the required local lan-
guage, the displays come up in German.
Carry out the country initialization on the system telephone with internal station number 100
(port 01). This process loads the country-specific language and features and ensures that the
system meets the country’s conditions for approval.
In Germany, no country adaptation is required after a reload because the system boots with the
German country code by default.
The next step involves selecting the password type.
Input procedure
Table 5-3 Entering the Country Code and Selecting the Password Type
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-7
start_h3.fm
Table 5-3 Entering the Country Code and Selecting the Password Type
After you enter a country code, the default data is only guaranteed to load correctly
> if the system software has been officially released for that country.
P31003-H3560-S100-3-7620, 03/06
5-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3800
Introduction
Corresponding to the configuration, the system station number must be entered (without the
DID number or attendant code) on the system telephone that is assigned 100 as its internal
station number.
The system station number is determined by the network or service provider.
Depending on the configuration type, system station numbers should not be entered for
point-to-multipoint operation or for tie trunks to HiPath 4000, for example.
Example
Port number: 98008
National number: 2302 (prefix without 0)
International number: 49 (country code)
Station number type: international
Input procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-9
start_h3.fm
Changes to the system (for example key programming) made using HiPath 3000
> Manager E during an offline programming session will be lost when the database is
loaded.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
P31003-H3560-S100-3-7620, 03/06
5-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3750 and HiPath 3700
Warning
7 Only authorized service personnel should start up the system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-11
start_h3.fm
Procedure
Step Activity
1. Plug in the power supply cable on the power supply unit(s).
2. Monitor the Run LED of the CBCPR. The individual steps of the system boot
(Table 5-6) can be observed this way.
The HiPath 3750 or HiPath 3700 is ready when the date “1. JAN 00” and the time
> “00:00” appear in the display on the system telephone.
P31003-H3560-S100-3-7620, 03/06
5-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3750 and HiPath 3700
If Then
Missing or defective board No action.
Different board type The system does not automatically activate the board.
Underequipped or same Board is activated. The same station range is used.
board variant
Over-equipped board variant Board is activated. The old station range is activated and the
ports associated with the new board are inserted at the end.
The ports are split if there is no contiguous station range avail-
able.
New board in empty slot ● Board was the last one installed in accordance with the
placement sequence:
All boards are activated and the numbering plan continues
without a gap.
● Board was inserted ahead of another board in the place-
ment sequence:
Board is activated and appended to the last board in the
numbering plan.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-13
start_h3.fm
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of the
numbering plan:
P31003-H3560-S100-3-7620, 03/06
5-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3750 and HiPath 3700
Since the system software no longer provides all languages, some systems no long-
> er start up in the customary local language after the country code is entered. You
must now load the local language prior to country initialization, using HiPath 3000
Manager E (see information on multilingual text output in the Feature Description
HiPath 3000/5000).
After carrying out the country initialization, but before loading the required local lan-
guage, the displays come up in German.
Carry out the country initialization on the system telephone with internal station number 100
(port 01). This process loads the country-specific language and features and ensures that the
system meets the country’s conditions for approval.
In Germany, no country adaptation is required after a reload because the system boots with the
German country code by default.
The next step involves selecting the password type.
Input procedure
Table 5-7 Entering the Country Code and Selecting the Password Type
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-15
start_h3.fm
Table 5-7 Entering the Country Code and Selecting the Password Type
After you enter a country code, the default data is only guaranteed to load correctly
> if the system software has been officially released for that country.
P31003-H3560-S100-3-7620, 03/06
5-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3750 and HiPath 3700
Introduction
Corresponding to the configuration, the system station number must be entered (without the
DID number or attendant code) on the system telephone that is assigned 100 as its internal
station number.
The system station number is determined by the network or service provider.
Depending on the configuration type, system station numbers should not be entered for
point-to-multipoint operation or for tie trunks to HiPath 4000, for example.
Example
Port number: 98008
National number: 2302 (prefix without 0)
International number: 49 (country code)
Station number type: international
Input procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-17
start_h3.fm
Changes to the system (for example key programming) made using during an HiPath
> 3000 Manager E offline programming session will be lost when the database is load-
ed.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
P31003-H3560-S100-3-7620, 03/06
5-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
5.4 Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
This section contains information on how to start up the HiPath 3550, HiPath 3350, HiPath 3500
and HiPath 3300 communication systems.
Warning
7 Only authorized service personnel should start up the system.
Caution
7 For safety, operate HiPath 3500 and HiPath 3300 only with the housing front closed.
Always use dummy panels (C39165-A7027-B115) to close slots that are not
equipped with boards.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-19
start_h3.fm
Procedure
Step Activity
1. Plug in the power supply cable and, where applicable, the battery cable.
2. Monitor the Run LED of the central controller. The individual steps of the system
boot (Table 5-10) can be observed this way.
HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 RUN LED
The central board has a RUN LED that indicates the system status.
Table 5-10 RUN LED - LED Status Meaning
The system is ready when the date “1. JAN 00” and the time “00:00” appear in the
> display on the system telephone.
P31003-H3560-S100-3-7620, 03/06
5-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
If Then
Missing or defective board No action.
Different board type The system does not automatically activate the board.
Underequipped or same Board is activated. The same station range is used.
board variant
Over-equipped board variant Board is activated. The old station range is activated and the
ports associated with the new board are inserted at the end.
The ports are split if there is no contiguous station range avail-
able.
New board in empty slot ● Board was the last one installed in accordance with the
placement sequence:
All boards are activated and the numbering plan continues
without a gap.
● Board was inserted ahead of another board in the place-
ment sequence:
Board is activated and appended to the last board in the
numbering plan.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-21
start_h3.fm
Procedure: Reinitialization
Proceed as follows if measures to expand the system configuration require reinitialization of the
numbering plan:
P31003-H3560-S100-3-7620, 03/06
5-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
Procedure
Press and hold down the reset switch for at least 5 seconds (RUN LED goes out). If you do not
hold down the reset switch for a full 5 seconds, the system may perform a reset rather than a
reload or may not reload properly.
Since the system software no longer provides all languages, some systems no long-
> er start up in the customary local language after the country code is entered. You
must now load the local language prior to country initialization, using HiPath 3000
Manager E (see information on multilingual text output in the Feature Description
HiPath 3000/5000).
After carrying out the country initialization, but before loading the required local lan-
guage, the displays come up in German.
Carry out the country initialization on the system telephone with the internal station number 100
(HiPath 3550 and HiPath 3500) or 11 for (HiPath 3350 and HiPath 3300) (port 01). This process
loads the country-specific language and features and ensures that the system meets the coun-
try’s conditions for approval.
In Germany, no country adaptation is required after a reload because the system boots with the
German country code by default.
The next step involves selecting the password type.
Input procedure
Table 5-11 Entering the Country Code and Selecting the Password Type
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-23
start_h3.fm
Table 5-11 Entering the Country Code and Selecting the Password Type
Note
Entering the country code starts the system. Any data that has already been stored, such as
system speed-dialing destinations and classes of service, is deleted or reset to the default val-
ue.
After you enter a country code, the default data is only guaranteed to load correctly
> if the system software has been officially released for that country.
Table A-3, HiPath 3550, HiPath 3350 and HiPath 3500 have not been introduced in
some of the countries listed in HiPath 3300. The correct loading of the default data
is not guaranteed for those countries.
P31003-H3560-S100-3-7620, 03/06
5-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
Introduction
Corresponding to the configuration, the system station number must be entered (without the
DID number or attendant code) on the system telephone that is assigned 100 as its internal
station number for HiPath 3550 and HiPath 3500 and 11 in the case of HiPath 3350 and HiPath
3300.
The system station number is determined by the network or service provider.
Depending on the configuration type, system station numbers should not be entered for
point-to-multipoint operation or for tie trunks to HiPath 4000, for example.
Example
● Port number: 98008
● National number: 2302 (prefix without 0)
● International number: 49 (country code)
● Station number type: international
Input procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 5-25
start_h3.fm
Changes to the system (for example key programming) made using during an HiPath
> 3000 Manager E offline programming session will be lost when the database is load-
ed.
When you program the system offline, the assignments of trunk and subscriber ports
depend on the order in which the boards are inserted. Usually, the boards are insert-
ed from the lowest slot to the highest.
Refer to the HiPath 3000 Manager E Help for information on programming individual features.
P31003-H3560-S100-3-7620, 03/06
5-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Overview
6.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Introduction, page 6-3
Software Structure, page 6-6
Notes on Open Numbering in a HiPath 3000/5000 Network, page 6-9
Installation Requirements, page 6-10
HiPath 5000, page 6-13
● Preparing for Installation, page 6-13
● Integrating the HiPath 5000 Server in the Customer LAN, page 6-14
● HiPath 5000 Installing Standard Components, page 6-15
● Installing HiPath ComScendo Service, page 6-23
● Installing HiPath Fault Management, page 6-32
● Installing the TAPI Service Provider, page 6-36
● Installing the HiPath Inventory Server Separately, page 6-38
● Verifying Installation, page 6-43
Modifying HiPath 5000 Components (Retro-Fitting, Updating, Deleting), page 6-45
● Version-Wide Upgrading of a HiPath 5000 Installation, page 6-46
Performing Licensing, page 6-48
Optimizing Operating System Settings, page 6-49
Perform HiPath 5000 Basic Configuration, page 6-51
● Configuring HiPath 5000 with HiPath ComScendo Service, page 6-52
● Reloading the HiPath ComScendo Service (if required), page 6-53
● Configuring HiPath 5000 RSM as a Central Administration Unit in an IP Network, page 6-
54
HiPath Manager PCM, page 6-58
GetAccount, page 6-59
● Parameters for Call Data Export, page 6-59
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-1
start_h5.fm
Topic
Connecting an Uninterruptible Power Supply to HiPath 5000, page 6-64
P31003-H3560-S100-3-7620, 03/06
6-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Introduction
6.2 Introduction
HiPath 5000 Real-Time Services Manager RSM is operated as a central administration unit in
an IP network of HiPath 3000 systems. All participating nodes can be administered from a cen-
tral point through the formation of a “single system image”.
HiPath 5000 RSM is the platform for providing applications at a central point and enables them
to be used by all stations in the IP network.
The HiPath ComScendo Service also supports the use of an integrated gatekeeper as well as
features for IP workpoint clients from HiPath ComScendo. Up to 1000 registered IP workpoint
clients and up to 250 CorNet IP lines (CorNet NQ protocol tunneled in H.323 via Annex M1) are
supported in this process.
The HiPath ComScendo Service is virtually a complete HiPath 3000 node that is only config-
ured as software on a PC. Apart from TDM-specific features (e.g. the connection of UP0/E sta-
tions, trunks and special stations such as door openers, etc.), all V6.0 features are available.
The HiPath ComScendo Service is administered over HiPath 3000 Manager E, while the
HG 1500 resources (see Page 10-37) are administered over Web-based Management (WBM).
Cross-platform use of HiPath ComScendo features (IP networking), for example in conjunction
with HiPath 4000, is implemented via CorNet-IP (CorNet-NQ protocol tunnelled in H.323 via an-
nex M1). HG 1500 in HiPath 3000 and HG3550 V2.0 in HiPath 4000 are prerequisites for
IP networking over CorNet IP.
Parts of the following setup for HiPath 5000 are optional and can be installed both on the HiPath
5000 Real-Time Services Manager RSM and on a separate PC.
● Feature Server (central administration service in a HiPath 3000/5000 network)
● Presence Manager (service for LED signaling of call processing station statuses and net-
work-wide DSS keys)
● HiPath ComScendo Service (gatekeeper and HiPath ComScendo features for IP workpoint
clients)
● HiPath 3000 Manager E (MS Windows-based tool for the administration of all service and
customer-specific data by Service)
● HiPath 3000 Manager C (MS Windows-based tool for the administration of customer-spe-
cific data by the customer)
● HiPath Software Manager (Web-based tool for upgrades (Upgrade Manager for HiPath
ComScendo Service and HG 1500) and backups (Backup Manager for HiPath ComScen-
do Service, HG 1500 and databases))
● Inventory Manager (service for detecting software components installed and system infor-
mation in a HiPath 3000/5000 network)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-3
start_h5.fm
● Customer License Agent CLA (service for analyzing and decrypting a HiPath License Man-
agement license file)
● Central License Manager CLM (CLA front-end for reading in licenses in online and offline
mode)
● Personal Call Manager PCM (Web-based application for the configuration and administra-
tion of personal call forwarding operations)
● HiPath FM Desktop V3.0 (Java-based application for error signaling)
● GetAccount (application that prepares generated call data records for further processing.)
P31003-H3560-S100-3-7620, 03/06
6-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Introduction
HiPath Cordless
Office
IP Network
optiClient 130 optiClient
V5.0 Attendant
HiPath 3750
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-5
start_h5.fm
Feature Server
The Feature Server is an essential component in the HiPath 5000 software architecture and
serves as a central point for administration and as a data interface for applications and middle-
ware. In addition, the Feature Server synchronizes the HG 1500 boards with all necessary data
for digit analysis in a HiPath 3000/5000 network.
The networked HiPath 3000 systems (nodes) are administered over the Feature Server. The
HiPath 3000 Manager E administration tool does not communicate with the individual systems
but exchanges data with the Feature Server. The Feature Server ensures that the networked
HiPath 3000 systems receive synchronized CDB data.
The individual systems are accessed directly by HiPath 3000 Manager E in the course of main-
tenance and online functions.
HG 1500 boards are still administered on a board-specific basis using Web-based manage-
ment (WBM).
The Feature Server is an MS Windows service that automatically starts at the same time as the
HiPath 5000 RSM.
Communication with the individual HiPath 3000 systems belonging to the network takes place
over their HG 1500 boards.
Feature Server
CDB 1
CDB 2
CDB 3
Figure 6-2 Customer Data Exchange Between the Feature Server and Nodes
P31003-H3560-S100-3-7620, 03/06
6-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Software Structure
The following figure shows the services and routines associated with the Feature Server.
AssCkds.dll
vsrv.exe Accs520x.dll
Accs520x.dll
Accs520x.dll
Accs520x.dll
Server Database
vdbaccess.dll
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-7
start_h5.fm
The following table shows the most important features of the Feature Server.
Table 6-1 Feature Server Components
Component Function
vsrv.exe Basic Feature Server component. As an MS Windows service, it starts all
other components.
vaplx.dll Logical interface for applications. Provides read-only and read/write access
to CDB data.
cars.exe The Call Address Resolution Server provides the HG 1500 boards with the
call numbers of all HiPath 3000 systems (nodes) that belong to the net-
work.
Note: Event 1027 confirms that the corresponding HG 1500 board was
successfully downloaded with the call numbers of all HiPath 3000 systems
associated with the network (see Section 12.3.3).
regserv- Following startup, the HG 1500 boards automatically log on to the Feature
er.exe Server over the Registration Server.
vsync.exe All “node-specific” CDB changes (for example, by key programming, Assis-
tant T) are reported by the node to the Feature Server’s VSYNC process.
This ensures the automatic synchronization of the Feature Server with the
new CDB data.
FCT.dll Interface to the systems for direct CDB data access.
Presence Manager
This is a Feature Server service for signaling the call processing station states “free”, “busy”
and “call” using the LEDs on the optiset E and optiPoint telephones in a HiPath 3000/5000 net-
work. You can pick up a call by pressing the appropriate button.
Call processing states can only be signaled for a station if the Presence Manager can set a
CSTA monitor point on the relevant station. The status of a MULAP call number cannot be sig-
naled, for example, because a CSTA monitor point cannot be set on a call number of this type.
The dssserver.exe service for the Presence Manager is installed with the HiPath 5000 software.
This is a user-configured service that receives its information from vaplx.dll. The TAPI Ser-
vice Provider is required for the Presence Manager to work.
P31003-H3560-S100-3-7620, 03/06
6-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Notes on Open Numbering in a HiPath 3000/5000 Network
The node number (Settings/System parameters.../Flags: Node number) and the in-
> coming PABX number for route 16 (HG 1500 route) (Settings/Lines / networking.../
Routes: PABX number - incoming) should be identical for every HiPath 3000 system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-9
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Installation Requirements
Minimum RAM
Up to Up to Up to Up to Up to
2 nodes 8 nodes 16 nodes 32 nodes 64 nodes1
HiPath 5000 V6.0 512 MB 1 GB 1 GB 1.5 GB 2 GB
+ HiPath FM V3.0
+ Teledata Office V3.0
+ HiPath Software Manag-
er
HiPath ComScendo Ser- + 100 MB + 100 MB + 100 MB + 100 MB not sup-
vice ported
HiPath Manager PCM + 90 MB + 90 MB + 90 MB + 90 MB + 90 MB
V2.0
HiPath ProCenter Office + 400 MB + 400 MB + 600 MB not sup- not sup-
V1.3 with HiPath Xpres- ported ported
sions V3.02
DLS + 250 MB + 250 MB + 250 MB + 250 MB + 250 MB
1 Networks are currently released with up to 32 nodes. Larger configurations can be released on a project-specific ba-
sis.
2 In this special configuration, HiPath Xpressions V3.0 supports up to 248 Unified Messaging users or 400 voice mail
users.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-11
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Component Description
Hard disk parti- The server PC hard disk should be divided into two NTFS partitions. The
tioning main partition C should have a capacity of at least 4 GB and should be re-
served for the operating system and the HiPath 5000 software.
For safety reasons, partitioning with the format FAT 16/32 is not permitted.
Hardware Make sure that no unnecessary hardware is connected to the server PC;
any sound cards should be removed.
Access privileg- To install HiPath 5000, you must log on to the operating system with admin-
es istrator rights or, if necessary, log on as the server domain administrator.
LAN integration Check to ensure that the server PC has been correctly integrated in the cus-
tomer LAN (see Section 6.6.2).
Miscellaneous All applications running in the background must be closed prior to software
installation.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-13
start_h5.fm
Network analysis must be performed before the relevant systems and applications
> are installed to guarantee smooth operation in the IP customer network. Network
analysis determines the conditions under which the IP customer’s network is suit-
able for a HiPath 3000/5000 network.
The data necessary for integrating the HiPath 5000 server, for example, IP address-
es, is defined as part of network analysis and in consultation with the customer (re-
quirements specifications).
The settings are made under Control Panel - Network - Protocols.
● Modify the IP address
● Adapt the subnet mask, gateway.
● Adapt the DNS entries, WINS entries.
● Once the data has been customized, a reboot is required.
● Test the LAN connection with a “ping” to another computer
● Integrate the HiPath 5000 in the Windows domain under Control Panel - Network - Identi-
fication (a domain administrator account is required here!)
P31003-H3560-S100-3-7620, 03/06
6-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
6.6.3.1 Overview
The installation program (Master Setup) enables both the basic installation of a HiPath 5000
system including middleware and components for system administration/analysis and the post-
installation of individual software components and tools (update, see Section 6.7).
Table 6-6 Software Components and Master Setup Tools
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-15
start_h5.fm
6.6.3.2 Licensing
Please refer to Chapter 8, “Licensing” for information on how to proceed.
A grace period of 30 days begins after startup. Licensing must be performed for all features,
interfaces, and products subject to mandatory licensing within this grace period.
HiPath 3000 Manager E comes with a customer-specific file which is used by the Customer Li-
cense Agent CLA to generate a GPCF (Grace Period Configuration File) file. This file ensures
that the maximum expansion of all features subject to mandatory licensing is possible within
the 30-day grace period. The system or systems are not licensed.
The system falls into licensing default if licensing is not performed within the 30-day grace pe-
riod. This means that features which subject to mandatory licensing will suffer from reduced
functionality.
P31003-H3560-S100-3-7620, 03/06
6-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Procedure
1. Insert the installation CD.
The installation program is started via the autorun function. Alternatively you can initiate
Setup via Windows Explorer under <CD-ROM drive letter>:\setup.exe.
2. Select the language you require for the Setup browser. German (Germany) and English
(USA) versions are currently available.
The system is prepared for installation.
3. Click Next to start the installation routine.
Important installation information is displayed.
This includes the latest information on installation. Please read this information carefully.
4. Click Next to proceed with the installation routine.
5. Select destination path.
Select the folder where you want to install the program.
Confirm the default folder c:\program files\siemens\hipath\ with Next or click
Browse and select a different folder.
6. Select program folder.
Select the location where the setup should create the new shortcuts.
Confirm the default folder HiPath with Next or select a different folder.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-17
start_h5.fm
Mark the components you want to install and unmark the ones you don’t.
P31003-H3560-S100-3-7620, 03/06
6-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
At this point your attention is drawn to the fact that a TAPI service provider must
> be installed for the current selection of components.
If this requirement is met, click Yes to continue with the procedure.
If there is no TAPI service provider installed, click No to cancel the procedure.
Install the TAPI service provider on the basis of the information in Section 6.6.6.
Then restart the master setup.
The Start Copying Files dialog appears.
Check if the correct destination directory and program group are specified and if all neces-
sary components are installed.
9. Click Next to start the copy operation.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-19
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Enter the trap destinations (if necessary) and the HiPath Fault Management desktop com-
munity names.
The FM Reporting Client does not have its own user interface. The trap destina-
> tions and community names defined during installation may only be changed by
uninstalling and then reinstalling the FM Reporting Client.
Users with sufficient knowledge of SNMP can change trap destinations and
community names by editing the file snmpd.cnf (see Appendix E).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-21
start_h5.fm
Configure the user account for the license agents (Customer License Agent CLA).
13. Click Next to proceed with the setup routine.
14. When all selected components are installed, a dialog appears in which you can terminate
the setup with Finish.
P31003-H3560-S100-3-7620, 03/06
6-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Procedure
1. Insert the installation CD.
The installation program is started via the autorun function. Alternatively you can initiate
Setup via Windows Explorer under <CD-ROM drive letter>:\setup.exe.
2. Select the language you require for the Setup browser. German (Germany) and English
(USA) versions are currently available.
The system is prepared for installation.
3. Click Next to start the installation routine.
Important installation information is displayed.
This includes the latest information on installation. Please read this information carefully.
4. Click Next to proceed with the installation routine.
5. Select destination path.
Select the folder where you want to install the program.
Confirm the default folder c:\program files\siemens\hipath\ with Next or click
Browse and select a different folder.
6. Select program folder.
Select the location where the setup should create the new shortcuts.
Confirm the default folder HiPath with Next or select a different folder.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-23
start_h5.fm
Select the HiPath ComScendo Service components you want to install and deselect the
ones you do not want to install.
P31003-H3560-S100-3-7620, 03/06
6-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Finally, check whether the correct target directory and program group have been specified.
To implement the setup for the HiPath ComScendo service, both a TFTP server and an FM
Reporting client must be installed on the relevant PC. Both components are automatically
selected and installed by the Master Setup.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-25
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Enter the trap destinations (if necessary) and the HiPath Fault Management desktop com-
munity names.
The FM Reporting Client does not have its own user interface. The trap destina-
> tions and community names defined during installation may only be changed by
uninstalling and then reinstalling the FM Reporting Client.
Users with sufficient knowledge of SNMP can change trap destinations and
community names by editing the file snmpd.cnf (see Appendix E).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-27
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Confirm the default or select a different country to define the international standard settings
for language, currency and date format.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-29
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Procedure
1. Open the status display with Start/Program Files/HiPath/HiPath 5000 State
Viewer.
2. The following appears:
Make sure that the server status is “Running” and that all service status indicators are
green.
Details about configuring the HiPath ComScendo service can be found in Section 6.10.1.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-31
start_h5.fm
Procedure
1. Insert the installation CD.
The installation program is started via the autorun function. Alternatively you can initiate
Setup via Windows Explorer under <CD-ROM drive letter>:\setup.exe.
2. Select the language you require for the Setup browser. German (Germany) and English
(USA) versions are currently available.
The system is prepared for installation.
3. Click Next to start the installation routine.
Important installation information is displayed.
This includes the latest information on installation. Please read this information carefully.
4. Click Next to proceed with the installation routine.
5. Select destination path.
Select the folder where you want to install the program.
Confirm the default folder c:\program files\siemens\hipath\ with Next or click
Browse and select a different folder.
6. Select program folder.
Select the location where the setup should create the new shortcuts.
Confirm the default folder HiPath with Next or select a different folder.
P31003-H3560-S100-3-7620, 03/06
6-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Select the HiPath Fault Management components you want to install and deselect the ones
you do not want to install.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-33
start_h5.fm
Check if the correct destination directory and program group are specified and if all neces-
sary components are installed.
9. Click Next to start the copy procedure.
The software license agreement is displayed. The license terms must be accepted before
continuing with the setup.
10. Confirm the license agreement with Yes.
11. The Choose Destination Location dialog appears.
Select the folder where you want to install the Java Runtime Environment.
Confirm the default folder c:\program files\javasoft\jre\<version>\ with Next
or click Browse and select a different folder.
P31003-H3560-S100-3-7620, 03/06
6-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-35
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
At the beginning of the installation routine (the precise time will depend on the
> installation components you selected), a dialog is displayed prompting you to
enable ACD support. Confirm this prompt with Yes.
The relevant ACD support utility can also be enabled or disabled at a later stage.
For further information, please refer to the online help for the TAPI 170 Service
Provider.
When a component is successfully installed, the associated configuration dialog opens.
You can set the required parameters here or postpone configuration until a later time.
6. When all of the selected components have been installed, a final dialog is displayed in
which you can conclude installation with Finish.
The TAPI Service Provider is now installed.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-37
start_h5.fm
Procedure
1. Insert the installation CD.
The installation program is started via the autorun function. Alternatively you can initiate
Setup via Windows Explorer under <CD-ROM drive letter>:\setup.exe.
2. Select the language you require for the Setup browser. German (Germany) and English
(USA) versions are currently available.
The system is prepared for installation.
3. Click Next to start the installation routine.
Important installation information is displayed.
This includes the latest information on installation. Please read this information carefully.
4. Click Next to proceed with the installation routine.
5. Select destination path.
Select the folder where you want to install the program.
Confirm the default folder c:\program files\siemens\hipath\ with Next or click
Browse and select a different folder.
6. Select program folder.
Select the location where the setup should create the new shortcuts.
Confirm the default folder HiPath with Next or select a different folder.
P31003-H3560-S100-3-7620, 03/06
6-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Select the HiPath Inventory components you want to install and deselect the ones you do
not want to install.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-39
start_h5.fm
Check if the correct destination directory and program group are specified and if all neces-
sary components are installed.
To be able to implement the setup for HiPath Inventory, both an FM Reporting client and a
Common Web Service must be installed on the relevant PC. Both components are auto-
matically selected and installed by the Master Setup.
P31003-H3560-S100-3-7620, 03/06
6-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Enter the trap destinations (if necessary) and the HiPath Fault Management desktop com-
munity names.
The FM Reporting Client does not have its own user interface. The trap destina-
> tions and community names defined during installation may only be changed by
uninstalling and then reinstalling the FM Reporting Client.
Users with sufficient knowledge of SNMP can change trap destinations and
community names by editing the file snmpd.cnf (see Appendix E).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-41
start_h5.fm
Enter the IP address and the port number of the PC where the database is installed (MSDE
SQL database server).
11. Confirm your entries with Next.
12. When installation is complete, a dialog appears in which you can terminate the setup with
Finish.
P31003-H3560-S100-3-7620, 03/06
6-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
HiPath 5000
Administrator user rights are required to use the full range of Computer Management
> functions.
Working with Computer Management requires an appropriate level of familiarity with
the operating system.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-43
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Modifying HiPath 5000 Components (Retro-Fitting, Updating, Deleting)
The WinAccount software for evaluating call data records is no longer used in HiPath
> 3000/5000 V4.0 or later.
Call data records must be evaluated with WinAccount before starting an update be-
cause updating uninstalls the WinAccount application.
Refer to the WinAccount user manual for information about the procedure
Before starting the Setup maintenance program, note the following information:
7 ● The TAPI Service Provider configuration (configuration and lines - see TAPI 170
Service Provider Help) and the CDB files for all connected systems (refer to Hi-
Path 3000 Manager E Help) should be saved for security reasons.
● The HiPath 5000 server must be stopped (Start/Programs/HiPath/Hi-
Path 5000 State Viewer, Stop Server button).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-45
start_h5.fm
When upgrading from one version to another (from V5.0 to V6.0, for example), all
> components (features) must first be uninstalled. The components of the new version
can then be installed.
1. Save the current TAPI service provider configuration (configuration and lines - see TAPI
170 Service Provider Help).
2. Save the current CDB files of all connected systems (see HiPath 3000 Manager E Help).
3. Call up the HiPath 5000 State Viewer with Start/Programs/HiPath/HiPath 5000
State Viewer.
4. Exit the HiPath 5000 server by clicking Stop Server.
1. Insert the installation CD.
The installation program is started via the autorun function. Alternatively you can initiate
Setup via Windows Explorer under <CD-ROM drive letter>:\setup.exe.
2. Select the language you require for the Setup browser.
P31003-H3560-S100-3-7620, 03/06
6-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Modifying HiPath 5000 Components (Retro-Fitting, Updating, Deleting)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-47
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Optimizing Operating System Settings
Component Description
Optimizing the physical Windows 2000 Server is normally optimized for maximum throughput
memory as a file server. For a HiPath 5000 server, however, significantly less
memory is needed for the system-wide disk cache.
For this select the Balance Load option under Start/Settings/
Network and DC Connections/LAN Connection: Proper-
ties – File and Printer Sharing for Microsoft Net-
works: Properties
Optimizing the virtual To optimize the virtual memory, enter 512 MB as the Total paging
memory file size for all drives under Start/Settings/Control Panel/
System: Advanced – Performance Settings: Virtual
Memory: Change.
The same values should be entered for the virtual memory’s upper
and lower thresholds so that the paging file does not have to be ex-
tended during operation.
Optimizing availability If the operating system crashes (blue screen), it creates a file con-
taining debugging information from the paging file the next time the
system starts. If the size of this file is the same size as the system’s
physical memory, almost all of the virtual memory will be used for
generating this file during system startup.
This may cause certain services on the HiPath 5000 server to expe-
rience problems in starting up. To recover this problem, you should
go to Start/Settings/Control Panel – System – Advanced
– Startup and Recovery and select the option none under Write De-
bugging Information.
All other options are viable. The Auto restart option forces an auto-
matic restart in the event of a system crash, thus considerably in-
creasing the server’s availability.
SMTP service The operating system’s SMTP service should always be disabled as
HiPath 5000 provides its own SMTP link which may conflict with the
operating system’s service. To do this, go to Start/Settings/
Control Panel: Software – Add/Remove Windows Com-
ponents : Internet Information Service (IIS) – De-
tails: Remove SMTP Service.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-49
start_h5.fm
Component Description
Personal Call Manager and Internet Information Server
The Personal Call Manager software runs within the context of the IIS
user. When a Windows Server system is being installed for the first
time, it must be taken into account that the default security settings
for the wwwroot directory do not always grant the Personal Call
Manager the necessary access rights.
You must ensure that the user account used by the Personal Call
Manager (account for “anonymous access” on the standard website
- by default this is the IIS guest account IUSR_<PC name>) has full
access to the wwwroott\PCM directory.
The PCM requires the following local full access rights to the hard
disk: C:\temp and C:\InetPub\wwwroot\PCM\ where C:\In-
etPub\wwwroot means the standard directory of the IIS (in other
installations this may have a completely different name).
The option “Cache ISAPI Applications” must not be disabled. This
option can be found under Standard website – Properties – Home
Directory – Configuration – Application Mapping.
If the option were disabled, the Personal Call Manger would lose its
“memory” of the users currently logged on and the error message
“You are not logged on” would be displayed permanently ...”.
Application protocol Configure the following by right-clicking Properties under System
Log and Application Log in the operating system’s Event Viewer:
'Overwrite events as needed' and set 'Maximum log size' to approxi-
mately 2 MB.
P31003-H3560-S100-3-7620, 03/06
6-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-51
start_h5.fm
Procedure
1. StartHiPath 3000 Manager E.
2. Open the Transfer dialog using the File menu.
3. In the Communication Settings tab select IP-HiPath as the access and enter the IP ad-
dress of the HiPath 5000 with HiPath ComScendo Service in the appropriate field.
Select Read/Write CDB and load the customer database by clicking the System -> PC
button.
During the first login, the system requests the identity of the user and asks for a
> new password (for more information see Section 12.6.1.1, “Logon With User
Name and Password”).
4. Perform the customer-specific system programming.
Refer to the HiPath 3000 Manager E Help for information on programming individual fea-
tures.
5. Save the customer database.
6. Then switch to the Transfer dialog.
7. In the Communication Settings tab select IP-HiPath as the access and enter the IP ad-
dress of the HiPath 5000 with HiPath ComScendo Service in the appropriate field.
Select Read/Write Database. Set the Overwrite and Hardware flags and transfer the cus-
tomer database by clicking the PC –> System button.
Once transfer is complete, HiPath 5000 automatically performs a reset and then returns to
operation.
The HG 1500 resources (see Page 10-37) are to be administered with Web-based
> Management (WBM). Information about the procedure can be found in the Web-
based Management WBM Help.
P31003-H3560-S100-3-7620, 03/06
6-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
The PDS files must not be modified, as reading of the files using conventional tools
> and interpretation of the content is not possible without specialist knowledge.
Procedure
1. Call up the HiPath 5000 State Viewer with Start/Programs/HiPath/HiPath 5000
State Viewer.
2. Exit the HiPath 5000 server by clicking Stop Server.
3. Delete the files hicom.pds and hicom.pds.bak.
Note: This restores the default settings for the entire content of the customer database. All
country and customer-specific settings are lost.
4. Start the HiPath 5000 server by clicking Start Server in the HiPath 5000 State Viewer.
When operating correctly, the server state is shown as “Running”; “status indicators are green”
is shown for all services.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-53
start_h5.fm
Procedure
1. StartHiPath 3000 Manager E.
2. Activate the HiPath 5000 RSM/AllServe server by selecting File - HiPath 5000 RSM/
AllServe - Transfer or via the appropriate button in the toolbar.
The menu item File - HiPath 5000 RSM/AllServe - New - HiPath 5000 RSM/
> AllServe Server is only used to create a CDB memory generated offline.
P31003-H3560-S100-3-7620, 03/06
6-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
4. The PC to be used as the HiPath 5000 server should be entered in the Server field.
Note: If the required software is not installed on the specified PC, the error message “Hi-
Path 5000 RSM/AllServe Server not Installed on this PC” appears.
5. Load the central customer database by clicking the Server –> Manager button.
6. Then click Close.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-55
start_h5.fm
Procedure
1. To select the node to be added to the CDB, call File - HiPath 5000 RSM/AllServe - New
- HiPath 3000.
2. The Enter Source dialog appears.
P31003-H3560-S100-3-7620, 03/06
6-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Perform HiPath 5000 Basic Configuration
Apply the node data to the server net file by clicking the Add node button.
7. Finally, rewrite the data from HiPath 3000 Manager E to the HiPath 5000 server (Manager
–> Server button).
Refer to the Help for HiPath 3000 Manager E for additional information about the
> procedure.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-57
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
GetAccount
6.12 GetAccount
Overview
The call data records generated during HiPath 3000/5000 operation can be copied to a text file
for further processing using the GetAccount program.
The WinAccount software for evaluating call data records is no longer used in Hi-
> Path 3000/5000 V4.0 or later.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-59
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
GetAccount
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-61
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
GetAccount
To avoid uncontrolled folder growth with the transfer file, an option is available for de-
> leting the renamed transfer file after forwarding it for external use in this folder.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-63
start_h5.fm
Caution
7 For safety reasons and for protection against guarantee claims, changes to the UPS
settings may only be performed by specially trained technicians.
The manufacturer’s safety and operating instructions must be observed.
1 2 3 4 5 6
P31003-H3560-S100-3-7620, 03/06
6-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_h5.fm
HiPath 5000 Startup and Administration
Connecting an Uninterruptible Power Supply to HiPath 5000
No. Description
1 LED displays the status of the P 500 UPS.
● green = input voltage (line voltage) is functioning
● red = UPS is suppling voltage or fault has been detected
2 Display shows UPS operating status
● NORMAL
● CHARG‘G
● BATTERY
and reports the charging status of the battery (25, 50, 75 or 100%).
3 On/off switch
4 Input (jack for input voltage (line voltage))
There is a cavity under the jack for the input fuse (with spare fuse enclosed).
5 3-pin DIP-FIX switch:
● 1: reduces the response voltage (minimum line voltage value before UPS activation)
– 10 V with 220/240-V systems
– 5 V with 110/120-V systems.
● 2: increases the response voltage by 5%
● 3: reduces the response voltage by 5%
Switch positions normally: DIP FIX 1 = off, DIP FIX 2 and 3 = on
6 Reset key
● deactivates the acoustic alarm if the input voltage fails, that is, when using the UPS.
This alarm cannot be deactivated if the battery voltage falls under a certain value.
● activates the UPS cold start.
To protect the battery from deep discharging, the UPS can only be activated when
the line voltage is connected. By activating the “on” switch (1) and then pressing the
reset key, the P 500 UPS can also be activated without a network connection (cold
start).
The connected server must be disconnected before a cold start.
The P 500 UPS needs between 5 and 20 s to reach the set output voltage. To avoid
malfunctions the connected server should not be connected immediately.
7 9-pin jack for connection to the communication server
NOT USED IN HiPath 3000/5000.
Special monitoring software can shut down the specified server via this jack, for exam-
ple, in the case of extended power failures.
8 Jacks for power supply to the communication server to be monitored.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 6-65
start_h5.fm
P31003-H3560-S100-3-7620, 03/06
6-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_3g.fm
Starting HiPath 3000 as a Gateway
Overview
7.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Starting HiPath 3800 as a Gateway, page 7-2
Starting HiPath 3700 as a Gateway, page 7-4
Starting HiPath 3500 as a Gateway, page 7-6
Starting HiPath 3300 as a Gateway, page 7-8
7.2 Introduction
So-called gateways provide the HiPath 5000 with interfaces for trunk and tie trunk connections
to the telecommunications network. In V6.0, the HiPath 3800, HiPath 3700, HiPath 3500, and
HiPath 3300 systems can be used as gateways.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 7-1
start_3g.fm
7.3.1 Prerequisites
Warning
7 Only authorized service personnel should install and start up the system.
Refer to Section 4.2.1 for information on the tools and resources needed to install the HiPath
3800 system.
To ensure that IP addresses are not assigned more than once in the customer net-
> work, you must ping each new IP address to be configured before each IP address
is assigned. If an IP address responds, then this address cannot be used again.
Table 7-1 HiPath 3800 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
7-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_3g.fm
Starting HiPath 3000 as a Gateway
Starting HiPath 3800 as a Gateway
Table 7-1 HiPath 3800 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 7-3
start_3g.fm
7.4.1 Prerequisites
Warning
7 Only authorized service personnel should install and start up the system.
Refer to Section 4.3.1 for information on the tools and resources needed to install the HiPath
3700 system.
To ensure that IP addresses are not assigned more than once in the customer net-
> work, you must ping each new IP address to be configured before each IP address
is assigned. If an IP address responds, then this address cannot be used again.
Table 7-2 HiPath 3700 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
7-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_3g.fm
Starting HiPath 3000 as a Gateway
Starting HiPath 3700 as a Gateway
Table 7-2 HiPath 3700 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 7-5
start_3g.fm
7.5.1 Prerequisites
Warning
7 Only authorized service personnel should install and start up the system.
Refer to Section 4.4.1 for information on the tools and resources needed to install the HiPath
3500 system.
To ensure that IP addresses are not assigned more than once in the customer net-
> work, you must ping each new IP address to be configured before each IP address
is assigned. If an IP address responds, then this address cannot be used again.
Table 7-3 HiPath 3500 as a Gateway - Procedure for System Installation and Startup
Note: Analog workpoint clients can be connected to the CBRC’s T/R ports in emer-
gencies. This ensures telephone operation via the telecommunications network in
the event of IP network failure.
P31003-H3560-S100-3-7620, 03/06
7-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_3g.fm
Starting HiPath 3000 as a Gateway
Starting HiPath 3500 as a Gateway
Table 7-3 HiPath 3500 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 7-7
start_3g.fm
7.6.1 Prerequisites
Warning
7 Only authorized service personnel should install and start up the system.
Refer to Section 4.4.1 for information on the tools and resources needed to install the HiPath
3300 system.
To ensure that IP addresses are not assigned more than once in the customer net-
> work, you must ping each new IP address to be configured before each IP address
is assigned. If an IP address responds, then this address cannot be used again.
Table 7-4 HiPath 3300 as a Gateway - Procedure for System Installation and Startup
Note: Analog workpoint clients can be connected to the CBRC’s T/R ports in emer-
gencies. This ensures telephone operation via the telecommunications network in
the event of IP network failure.
9. Making IP connections
Perform the IP connection over the HG 1500 board HXGR3.
For information on startup and configuration, refer to the HG 1500 Administration
Manual.
P31003-H3560-S100-3-7620, 03/06
7-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
start_3g.fm
Starting HiPath 3000 as a Gateway
Starting HiPath 3300 as a Gateway
Table 7-4 HiPath 3300 as a Gateway - Procedure for System Installation and Startup
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 7-9
start_3g.fm
P31003-H3560-S100-3-7620, 03/06
7-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Overview
8 Licensing
8.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Introduction, page 8-2
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0, page 8-4
● Products and Components subject to Mandatory Licensing, page 8-4
● Grace Period, page 8-7
● License Failure Period, page 8-7
● Performing Licensing, page 8-8
Licensing Scenarios, page 8-13
● HiPath 3000 as a Standalone System, page 8-13
● Networked HiPath 3000 Systems without HiPath 5000 RSM, page 8-14
● Networked HiPath 3000 Systems with HiPath 5000 RSM, page 8-15
● Upgrading to HiPath 3000 V6.0, HiPath 5000 V6.0, page 8-18
● Combining Standalone Systems (HiPath 3000) to Form a Network with HiPath 5000
RSM, page 8-21
● Removing a Standalone System from a Network with HiPath 5000 RSM, page 8-23
● Replacing License-sensitive Hardware (Changing the MAC Address), page 8-24
Licensing optiClient Attendant, page 8-27
● optiClient Attendant V7.0 Connected to HiPath 3000 V6.0, page 8-27
● optiClient Attendant V7.0 Connected to HiPath 3000 < V5.0, page 8-29
● Upgrading optiClient Attendant V6.0 –> V7.0 when Upgrading to HiPath 3000 V5.0 or Lat-
er, page 8-31
● Upgrade optiClient Attendant V6.0 –> V7.0 on HiPath 3000 < V5.0, page 8-33
● Changing Licenses on an optiClient Attendant V7.0 when Upgrading to HiPath 3000 V5.0
or Later, page 8-35
Protection Against License Manipulation, page 8-37
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-1
licensing.fm
Licensing
Introduction
8.2 Introduction
Versions 5.0 and later of HiPath 3000 and HiPath 5000 use a new, centralized licensing proce-
dure known as HiPath License Management. The procedure is used in all HiPath products, for
example communication systems, workpoint clients, and applications.
To license a product you must first establish a connection with the Central License Server (CLS)
via the Customer License Manager (CLM). The customer-specific data entered is used to
uniquely identify the product configuration for which the relevant license file is to be supplied in
encrypted format. The license file contains the licenses for all products which are subject to
mandatory licensing.
The CLM is responsible for activating the license file and allocating it to the Customer License
Agent (CLA). This is where the license data is validated. Distribution of the licenses to the indi-
vidual products using HiPath 3000 Manager E can then begin.
P31003-H3560-S100-3-7620, 03/06
8-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Introduction
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-3
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
8-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
The following features which are subject to mandatory licensing are licensed using separate
license files:
● VPN Workpoint Clients
● CSTA Service Provider (CSP)
● TAPI Service Provider (TSP)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-5
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
8-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-7
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
The details specified below are based on the assumption that valid license files are
> available to the user.
During installation of the Customer License Agent CLA on the service PC or on the HiPath 5000
server (see Figure 8-2), an import subdirectory is created in the installation directory.
If the user has received a valid license file (<license>.xml), there are two options:
● The license file can be stored manually in the specified subdirectory import.
● The Customer License Manager CLM can be activated and used to make the license file
automatically available for the CLA. Information about this can be found in the Customer
License Manager online help.
The license file in XML format contains information about all products that are subject to man-
datory licensing and the MAC address with which these licenses are linked. Feature IDs define
the number of licenses available and the length of time for which they are valid. A signature en-
sures that subsequent manipulation of the license file content is always detected. Invalid
changes to the license file are therefore not possible.
Distribution of the licenses to the relevant features, interfaces, and products is performed using
HiPath 3000 Manager E.
P31003-H3560-S100-3-7620, 03/06
8-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
Service PC
with
– HiPath 3000 Manager E HiPath 5000 RSM
– Customer License Agent with
(CLA) – HiPath 3000 Manager E
– Customer License Client – Customer License Agent
(CLC) (CLA)
– Customer License Client
(CLC)
Customer data-
base CDB with li-
Customer database
censes
CDB with licenses
HiPath 3750
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-9
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
8-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-11
licensing.fm
Licensing
Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0
P31003-H3560-S100-3-7620, 03/06
8-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
During production, the HiPath 3000 control boards are assigned a board-specific
> number with a MAC address that is unique worldwide. To guarantee unique licens-
ing, the license file is linked to the MAC address of a HiPath 3000 control board. The
various licensing scenarios are described below.
Procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-13
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
8-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
When a single CDB is downloaded from a HiPath 3000/5000 network, only the li-
> cense-sensitive CDB content is displayed. It is not possible to make any changes.
A cyclic check carried out every 24 hours guarantees continuous protection against manipula-
tion. Each node belonging to the network sends a request to the Feature Server to verify wheth-
er the license is still valid. The time at which the daily check takes place depends on the time
at which licensing takes place. The time of the daily check is redefined with each system reset.
Example: Licensing takes place at 5:00 p.m. Based on the 24-hour cycle, this means that the
licensing check begins at 5:00 p.m. every day.
A system reset is performed at 10:00 p.m. The time of the daily check is redefined as a result.
The licensing check begins at 10:00 p.m. every day with immediate effect.
Each additional reset results in the time of the daily check being redefined.
The system distinguishes between the following two types of error:
● The Feature Server is unable to reach the first node needed for licensing. The 30-day Li-
cense Failure Period begins.
● A standalone HiPath 3000 system (node) is unable to reach the Feature Server. The 30-
day License Failure Period begins.
If the error is rectified within 30 days, the system(s) revert(s) to the licensed state. If the error
has not been rectified by the time the 30-day license failure period has expired, the systems
enter system default mode. This means that features which subject to mandatory licensing will
suffer from reduced functionality.
Procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-15
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
8-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-17
licensing.fm
Licensing
Licensing Scenarios
Procedure
P31003-H3560-S100-3-7620, 03/06
8-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-19
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
8-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
Procedure
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-21
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
8-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-23
licensing.fm
Licensing
Licensing Scenarios
Procedure
P31003-H3560-S100-3-7620, 03/06
8-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-25
licensing.fm
Licensing
Licensing Scenarios
P31003-H3560-S100-3-7620, 03/06
8-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing optiClient Attendant
Procedure
1 2
6
optiClient HiPath 3000
Attendant 1 Manager E 3
V.24,
USB or HiPath 3000 5
TCP/IP V6.0 CLC
optiClient
CLA
Attendant 6
(CLS)
4
CLM
Figure 8-3 Procedure for Licensing optiClient Attendant V7.0 on HiPath 3000 V6.0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-27
licensing.fm
Licensing
Licensing optiClient Attendant
P31003-H3560-S100-3-7620, 03/06
8-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing optiClient Attendant
Procedure
optiClient At-
tendant 1
V.24, 2
HiPath 3000 USB or CLA
< V5.0 TCP/IP CLC 3
optiClient At- 4
tendant 6 (CLS)
CLM
CLC
Figure 8-4 Procedure for Licensing optiClient Attendant V7.0 on HiPath 3000 < V5.0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-29
licensing.fm
Licensing
Licensing optiClient Attendant
P31003-H3560-S100-3-7620, 03/06
8-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing optiClient Attendant
Procedure
The procedure described below assumes that the HiPath 3000 upgrade to V5.0
> has already been completed.
1 2
6
optiClient HiPath 3000
Attendant 1 Manager E 3
V.24,
USB or HiPath 3000 5
TCP/IP V5.0 CLC
optiClient
CLA
Attendant 6
(CLS)
4
CLM
Figure 8-5 Licensing procedure when upgrading optiClient Attendant V6.0 –> V7.0 on Hi-
Path 3000 V5.0 or later
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-31
licensing.fm
Licensing
Licensing optiClient Attendant
P31003-H3560-S100-3-7620, 03/06
8-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing optiClient Attendant
8.5.4 Upgrade optiClient Attendant V6.0 –> V7.0 on HiPath 3000 < V5.0
As part of the optiClient Attendant upgrade, licensing is also upgraded from V6.0 to V7.0. In
order to ensure unique licensing, the new license file is linked with the MAC address of the CLA
PC.
Procedure
optiClient At-
tendant 1
V.24, 2
HiPath 3000 USB or CLA
< V5.0 TCP/IP CLC 3
optiClient At- 4
tendant 6 (CLS)
CLM
CLC
Figure 8-6 Procedure for Licensing when Upgrading optiClient Attendant V6.0 –> V7.0 on
HiPath 3000 < V5.0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-33
licensing.fm
Licensing
Licensing optiClient Attendant
P31003-H3560-S100-3-7620, 03/06
8-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Licensing optiClient Attendant
Procedure
CLC 2
1 5
V.24, USB or TCP/IP
optiClient At-
tendant
(CLS)
HiPath 3000
V5.0 3 4
HiPath 3000
Manager E
7
CLC 6
CLA
CLM
Figure 8-7 Changing Licenses on an optiClient Attendant V7.0 when upgrading to HiPath
3000 V5.0 or later
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-35
licensing.fm
Licensing
Licensing optiClient Attendant
P31003-H3560-S100-3-7620, 03/06
8-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
licensing.fm
Licensing
Protection Against License Manipulation
To guarantee the security and consistency of the product licenses generated, chang-
> es to the system time on the PC of an installed Customer License Agent (CLA) must
not exceed one day.
If the system clock is reset by more than one day, the Customer License Agent stops
functioning and cannot be reactivated. The full functionality of the CLA on this PC
can only be restored by means of a repair or a reinstallation (see the License Agent
Installation Manual).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 8-37
licensing.fm
Licensing
Protection Against License Manipulation
P31003-H3560-S100-3-7620, 03/06
8-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Overview
9.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Expanding HiPath 3000, page 9-2:
● Replacing Peripheral Boards for HiPath 3800, page 9-2
● Replacing Peripheral Boards for HiPath 3750 and HiPath 3700, page 9-4
● Connecting a printer, page 9-6
● ECR with HiPath 3700, HiPath 3500, HiPath 3300 (not for U.S. and Canada), page 9-8
● Connecting Special Equipment, page 9-24
Upgrading HiPath 3000 to V6.0, page 9-29
● Hardware Upgrade, page 9-29
● Software Upgrade, page 9-31
Converting the customer database when changing a system, page 9-36
● Converting the customer database from HiPath 3750/HiPath 3700 to HiPath 3800, page
9-36
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-1
exup.fm
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards).
HiPath 3800 lets you remove and insert peripheral boards during operation (hot plugging). The
following startup rules apply.
Caution
7 To ensure that the system operates without blocking, you must follow the rules in
Section 4.2.5 concerning board configuration.
If Then
Inserting new board Board is integrated into the system according to the rules for initial
in free slot startup (Section 4.2.5.6).
● System with default numbering plan
The station numbers from the new board are appended (consec-
utively and in ascending order) to the numbers already assigned.
● System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000 Manager E or Assistant T, you can assign a spe-
cific station to a port. If the number is already assigned to a different
object, you can switch both numbers.
Replacing board with Board is activated. The same station range is used.
same or under
equipped board type
P31003-H3560-S100-3-7620, 03/06
9-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
If Then
Replacing board with Board is activated. The old station range is activated and the ports as-
over-equipped board sociated with the new board are inserted at the end. The ports are split
of same type if there is no contiguous station range available.
In the case of subscriber line modules, you can use HiPath 3000 Man-
ager E to retain the old station data by copying it to the new board, or
you can delete it and reset the default state. Copying is not possible
for trunk boards.
Replacing with a dif- The system does not automatically activate the board.
ferent board type After removing the old board, you can delete it from the database us-
ing HiPath 3000 Manager E or Assistant T.
After you have inserted the new board, the system activates it as if it
had been inserted into a free slot. However, the CDB area used by the
old board is left as a gap.
In the case of subscriber line modules, you can use HiPath 3000 Man-
ager E to retain the old station data by copying it to the new board, or
you can delete it and reset the default state. Copying is not possible
for trunk boards.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-3
exup.fm
9.2.2 Replacing Peripheral Boards for HiPath 3750 and HiPath 3700
Caution
7 Always wear an antistatic wristband when working on the system (especially when
handling boards).
HiPath 3750 and HiPath 3700 let you remove and insert peripheral boards during operation (hot
plugging). The following startup rules apply.
Caution
7 To ensure that the system operates without blocking, you must follow the rules in
Section 4.3.6 concerning board configuration.
If Then
Inserting new board Board is integrated into the system according to the rules for initial
in free slot startup (Page 4-156).
● System with default numbering plan
The station numbers from the new board are appended (consec-
utively and in ascending order) to the numbers already assigned.
● System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000 Manager E or Assistant T, you can assign a spe-
cific station to a port. If the number is already assigned to a different
object, you can switch both numbers.
Replacing board with Board is activated. The same station range is used.
same or under
equipped board type
Replacing board with Board is activated. The old station range is activated and the ports as-
over-equipped board sociated with the new board are inserted at the end. The ports are split
of same type if there is no contiguous station range available.
In the case of subscriber line modules, you can use HiPath 3000 Man-
ager E to retain the old station data by copying it to the new board, or
you can delete it and reset the default state. Copying is not possible
for trunk boards.
P31003-H3560-S100-3-7620, 03/06
9-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
If Then
Replacing with a dif- The system does not automatically activate the board.
ferent board type After removing the old board, you can delete it from the database us-
ing HiPath 3000 Manager E or Assistant T.
After you have inserted the new board, the system activates it as if it
had been inserted into a free slot. However, the CDB area used by the
old board is left as a gap.
In the case of subscriber line modules, you can use HiPath 3000 Man-
ager E to retain the old station data by copying it to the new board, or
you can delete it and reset the default state. Copying is not possible
for trunk boards.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-5
exup.fm
Caution
7 Follow the safety and operating instructions provided by the printer manufacturer.
Introduction
You can use a printer as a CDR printer (serial data transmission) or as a call charge computer
output device (parallel data transmission).
DCD 8 8 DCD
DTR 20 20 DTR
GND 7 7 GND 2)
1) Frame ground
2) Signal ground
P31003-H3560-S100-3-7620, 03/06
9-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Output formats
For information about the output formats (compressed or uncompressed) for call detail record-
ing central, see HiPath 3000/5000 Feature Description.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-7
exup.fm
9.2.4 ECR with HiPath 3700, HiPath 3500, HiPath 3300 (not for U.S. and
Canada)
Danger
7 An expansion cabinet rack (ECR) equipped with an external power supply unit
(EPSU2-R) may only be operated if the housing is closed.
Before opening the housing, disconnect the ECR from the power supply by
● setting the switches for battery voltage and line voltage on the ECR’s front panel
to “Off”.
● removing the battery fuse on the ECR front panel and
● unplugging all power and connection cables.
Introduction
When installing the system, an ECR in the 19-inch cabinet is required if
● emergency battery operation is necessary during a power failure or if the system requires
uninterruptible power.
The necessary batteries are installed in the ECR.
● the internal system power supply unit for HiPath 3500 or HiPath 3300 is not sufficient
enough to provide power to the overall telephone configuration (corded or cordless tele-
phones).
In this case, the EPSU2-R external power supply unit should be installed in the ECR.
P31003-H3560-S100-3-7620, 03/06
9-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-9
exup.fm
If an EPSU2-R external power supply unit is installed in the ECR, the following additional dis-
play and control elements are also included:
● EPSU2-R 2.5 A/T [4] battery fuse (warning: do not confuse with battery fuse on the ECR
front panel)
● LED [5] for the -48-V output voltage (DC output) in the EPSU2-R (see Table 9-3)
● LED [6] for the line input voltage (AC input) in the EPSU2-R (see Table 9-3)
[6]
[4] [5]
[2]
[1] [3]
P31003-H3560-S100-3-7620, 03/06
9-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-11
exup.fm
9.2.4.2 Components
● Expansion cabinet rack (ECR): S30777-U711-E901
The scope of delivery includes:
– A mounting set for installing the ECR in a 19-inch cabinet: C39165-A7027-D1
– A mounting clamp: D72571-A80-S3
– A toothed lock washer: D6797-A43-S657
● Mounting set for ECR wall installation or ECR table setup: C39165-A7027-D2
● EPSU2-R: S30122-K7221-X900
A cable for making the ECR – HiPath 3500 or HiPath 3300 electrical connection is included
in the delivery: C39195-Z7001-C14
● 4 batteries, 12 V/7 Ah: 4 x V39113-W5123-E891
● Connection cable, ECR (batteries) – HiPath 3700 (UPSM + power failure signaling (lamp-
wire connector): a relay connected in series can be used for signaling purposes, for exam-
ple.): C39195-A7002-B11
● Connection cable, ECR – HiPath 3500 or HiPath 3300: S30267-Z361-A10
Caution
7 Both of the above-mentioned connection cables are system-specific.
● C39195-A7002-B11 is exclusively designed for HiPath 3700.
● S30267-Z361-A10 is exclusively designed for HiPath 3500 and HiPath 3300.
Failure to observe the above may damage the power supply unit.
Use the power cable to ground the ECR. Fixed, separate grounding is not required.
>
The expansion cabinet rack ECR can be
● installed in a 19-inch cabinet (see Section 4.4.4.5).
● mounted on a wall (see Section 4.4.4.4).
● set up on a table using four adhesive mounting feet.
P31003-H3560-S100-3-7620, 03/06
9-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Danger
7 Before opening the housing, disconnect the ECR from the power supply by
● setting the switches for battery voltage and line voltage on the ECR’s front panel
to “Off”.
● removing the battery fuse on the ECR front panel and
● unplugging all power and connection cables.
When using the UPSM or the UPSC-DR as the uninterruptible power supply unit, you need to
install additional batteries in the ECR.
The ECR and batteries are packaged separately and included in the delivery. The batteries
should be installed as described in Section 9.2.4.4.1. Only use batteries approved for HiPath
3000.
Figure 9-5 shows the position of the four batteries inside the ECR.
The circuit diagram below illustrates the cable run between the batteries in the ECR and the
power supply unit of the system (UPSM for HiPath 3700, UPSC-DR for HiPath 3500 and HiPath
3300). The connection cable between the expansion cabinet rack ECR and the system cabinet
is also provided.
S1
X1 X2
1 L1 L1 1
2 N N 2
3 PE PE 3
PE
X3
3
Housing 4
1
+48 V
4 batteries 2
–48 V UP2
12 V/7 Ah
F1 T6.3 A –48 V BatB
S2
+48 V
Figure 9-4 HiPath 3700, HiPath 3500, HiPath 3300 - ECR With Batteries
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-13
exup.fm
Caution
7 When storing an ECR equipped with batteries or if the ECR is inactive for a long pe-
riod of time, remove the battery fuse (6.3 A/T) in the front panel of the ECR.
When shipping an ECR with built-in batteries, the batteries must be removed before-
hand.
1 2 3 4
P31003-H3560-S100-3-7620, 03/06
9-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Danger
7 Only V39113-W5123-E891 (12 V/7 Ah) batteries are released for connection to the
UPSC-DR/UPSM and installation in the ECR.
The use of other battery types is prohibited.
ECR is supplied with four batteries in a separate package. Proceed as follows to install the bat-
teries in the ECR:
Step Activity
1. Set the switches for battery voltage and line voltage on the ECR’s front panel to
“Off” (see Section 9.2.4.1).
2. Remove the battery fuse (ECR front panel) (see Section 9.2.4.1).
3. Unplug all of the ECR’s power and connection cables.
4. Remove the ECR housing cover: To do this, remove the three screws at the rear
and slide the housing cover back.
5. Remove the mounting screw [A] on the battery retainer [B].
[A] [B]
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-15
exup.fm
Step Activity
7. Insert the batteries carefully in the recesses provided [C].
[C]
P31003-H3560-S100-3-7620, 03/06
9-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Step Activity
9. Connect the batteries: To do this, slide the eight cable connector lugs [D] carefully
onto the two connection contacts on each of the four batteries.
[D]
10. Replace the ECR’s housing cover and secure the three mounting screws at the
rear.
11. Connect all of the ECR’s power and connection cables.
12. Insert the battery fuse (ECR front panel) (see Section 9.2.4.1).
13. Set the switches for battery voltage and line voltage on the ECR’s front panel to
“On” (see Section 9.2.4.1).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-17
exup.fm
Danger
7 An expansion cabinet rack (ECR) equipped with an external power supply unit
(EPSU2-R) may only be operated if the housing is closed.
Before opening the housing, disconnect the ECR from the power supply by
● setting the switches for battery voltage and line voltage on the ECR’s front panel
to “Off”.
● removing the battery fuse on the ECR front panel and
● unplugging all power and connection cables.
If the internal system power supply unit for HiPath 3500 or HiPath 3300 does not provide
enough power for the overall telephone configuration (corded and cordless telephones), an ad-
ditional power supply is necessary. In this case, the EPSU2-R external power supply unit
should be installed in the ECR.
Figure 9-7 shows the position of the EPSU2-R inside the ECR.
The block diagram below illustrates the cable run between the EPSU2-R and the batteries in-
side the ECR and the power supply unit of the system (UPSC-DR). The connection cable be-
tween the expansion cabinet rack ECR and the system cabinet is also provided.
P31003-H3560-S100-3-7620, 03/06
9-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
S1
X1 X2
1 L1 L1 1
2 N N 2
3 PE PE 3
PE
Housing
Input
Figure 9-6 HiPath 3500, HiPath 3300 - ECR With Batteries and EPSU2-R
Caution
7 When storing an ECR equipped with batteries or if the ECR is inactive for a long pe-
riod of time, remove the battery fuse (6.3 A/T) in the front panel of the ECR.
When shipping an ECR with built-in batteries, the batteries must be removed before-
hand.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-19
exup.fm
EPSU2-R
P31003-H3560-S100-3-7620, 03/06
9-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
Step Activity
1. Set the switches for battery voltage and line voltage on the ECR’s front panel to
“Off” (see Section 9.2.4.1).
2. Remove the battery fuse (ECR front panel) (see Section 9.2.4.1).
3. Unplug all of the ECR’s power and connection cables.
4. Remove the ECR housing cover: To do this, remove the three screws at the rear
and slide the housing cover back.
5. Cut off the plug on the fan connection line if there is one.
Strip both wire ends and attach wire end sleeves.
6. Connect both connection wires to the EPSU2-R terminal [A] as shown in
Figure 9-8. Connect the red wire (fan) to the white wire (EPSU2-R) and the black
wire (fan) to the black wire (EPSU2-R).
Figure 9-6 shows the cable run between EPSU2-R and the fan.
7. Replace the ECR’s housing cover and secure the three mounting screws at the
rear.
8. Connect all of the ECR’s power and connection cables.
9. Insert the battery fuse (ECR front panel) (see Section 9.2.4.1).
10. Set the switches for battery voltage and line voltage on the ECR’s front panel to
“On” (see Section 9.2.4.1).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-21
exup.fm
[A]
P31003-H3560-S100-3-7620, 03/06
9-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
If you install the fan at a later time, you must make sure that the identification ([B] in Figure 9-
9) is in the upper right corner when viewed from outside.
[B]
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-23
exup.fm
Connection options
The new central control boards CBCC (S30810-Q2935-A301) and CBRC (S30810-
> Q2935-Z301) only support TFE-S-Adapter S30122-K7696-T313.
You can also make a direct connection if needed. In this case, only voice connections to the
entrance telephone are possible, without the support of the opener and signal functions.
P31003-H3560-S100-3-7620, 03/06
9-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
DoorCom Analog
General information
The plus product DoorCom® Analog is a universal entrance telephone adapter box for Siedle
entrance telephones (such as the Vario TLM 612). It is released for use with all HiPath 3000
systems, V1.2 and later.
It is connected to an analog port in the system. DoorCom Analog behaves like an analog tele-
phone (DTMF tone dialing, detection, and control). It can be operated with DTMF signals.
DoorCom Analog can function only in combination with the following components:
● DoorCom Analog DCA 612-0
● Siedle-Vario TLM 612 entrance telephone
● Switching remote control interface DCSF 600
For the voice connection of an internal user to the entrance telephone: Without this module,
it is not possible to call back to the entrance telephone, for example, if a call was uninten-
tionally cleared down by the entrance telephone.)
● Power supply NG 602-0
Connection
Power supply
NG 602-0
HiPath 3000
Siedle-Vario
TLM 612
T/R
DoorCom Analog
DCA 612-0
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-25
exup.fm
DoorCom Analog
Set up station: Stations: Parameters:
Extension Type = Standard
Flags = Call waiting rejection on
System parameters:
Flags = DTMF automatic
Remote station (telephone)
Set up station: Stations: Parameters:
Flags = Call waiting rejection off
Flags = Missed Calls List
Device control features (open doors, select entrance telephone, etc.) can be programmed on
procedure keys. The stored DTMF signal sequence is sent to the application.
P31003-H3560-S100-3-7620, 03/06
9-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Expanding HiPath 3000
HiPath 3000
Active speak-
T/R ers only
SLA/SLAS ET
HiPath 3000
T/R ET T/R
SLA/SLAS Amplifier
Starting contact
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-27
exup.fm
Active speakers
HiPath 3000 T/R only
TML/TLA
Starting contact
REAL/STRB
P31003-H3560-S100-3-7620, 03/06
9-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V6.0
It is not possible to upgrade HiPath 3550 to HiPath 3500 or HiPath 3350 to HiPath
> 3300. This would require replacing the complete system.
Contol Boards
If the control board necessary for operating HiPath 3000/5000 V5.0 and higher is not available,
a replacement must be performed.
System Control board necessary for HiPath 3000/5000 V5.0 and higher
HiPath 3800 CBSAP, S30810-Q2314-X and higher
HiPath 3750 CBCPR, S30810-Q2936-X-J2 and higher
HiPath 3700
HiPath 3550 CBCC, S30810-Q2935-A301 and higher
HiPath 3350
HiPath 3500 CBRC, S30810-Q2935-Z301 and higher
HiPath 3300
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-29
exup.fm
HG 1500 boards
The HG 1500 boards listed in the following table are necessary for using the HG 1500 function-
ality with HiPath 3000/5000 V5.0 and higher. Unnamed HG 1500 boards must be replaced.
System HG 1500 board required for HiPath 3000/5000 V5.0 and higher
HiPath 3800 STMI2, S30810-Q2316-X100 and higher
HiPath 3750 HXGM3, S30810-Q2942-X and higher
HiPath 3700
HiPath 3550 HXGS3, S30810-Q2943-X and higher
HiPath 3350
HiPath 3500 HXGR3, S30810-K2943-Z and higher
HiPath 3300
P31003-H3560-S100-3-7620, 03/06
9-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V6.0
Lines
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-31
exup.fm
Yes
Open V4.0 CDB using HiPath Open V4.0 CDB using HiPath
3000 Manager E. 3000 Manager E.
Figure 9-16 Flowchart of CDB conversion from V4.0 to V5.0 or later (part 1 of 4)
P31003-H3560-S100-3-7620, 03/06
9-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V6.0
Configure S0 stations.
Delete all vCAPI clients in the S0
station.
Figure 9-17 Flowchart of CDB conversion from V4.0 to V5.0 or later (part 2 of 4)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-33
exup.fm
Figure 9-18 Flowchart of CDB conversion from V4.0 to V5.0 or later (part 3 of 4)
P31003-H3560-S100-3-7620, 03/06
9-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Upgrading HiPath 3000 to V6.0
Configure S0 stations.
Figure 9-19 Flowchart of CDB conversion from V4.0 to V5.0 or later (part 4 of 4)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-35
exup.fm
The following information refers to a CDB conversion during an upgrade, such as,
> ●
●
CDB HiPath 3750/HiPath 3700 V4.0 –> CDB HiPath 3800 V5.0
CDB HiPath 3750/HiPath 3700 V4.0 –> CDB HiPath 3800 V6.0
HiPath 3000 Manager E enables the conversion of a HiPath 3750/HiPath 3700 customer data-
base to a HiPath 3800 customer database without any data loss. A HiPath 3800-specific card
is installed during this operation for each HiPath 3750/HiPath 3700-specific card. The slots for
the individual cards are allocated according to the following criteria:
● The central control switches from slot 01 (HiPath 3750/HiPath 3700, basic cabinet) to slot 6
(HiPath 3800, basic cabinet).
● We endeavor to achieve identical utilization of the PCM segments.
HiPath 3750/HiPath 3700: Sixty-four time-division multiplex channels are available (see
Section 4.3.6).
HiPath 3800: One hundred and twenty-eight time-division multiplex channels are available
(see Section 4.2.5.7).
● We endeavor to accommodate as many cards as possible in the HiPath 3800 basic cabi-
net.
If the cards have to be configured manually, some data may be lost. This data will have to be
entered manually after CDB conversion.
Note the following special scenarios:
● SLMA (HiPath 3800) is used for SLA16N (HiPath 3750/HiPath 3700). Only 16 of the 24
ports on the SLMA are configured. To configure all 24 ports, the card has to be cancelled
first and then plugged in again. The irregularities in the logical port sequence resulting from
this will have to be corrected manually.
● DIUN2 (HiPath 3800) is used for TMS2 (HiPath 3750/HiPath 3700). Only the first of the two
S2M interfaces in the DIUN2 is configured. To configure both S2M ports, the card has to be
cancelled first and then plugged in again. The irregularities in the logical port sequence re-
sulting from this will have to be corrected manually.
Note: The B channels on the second S2M port are not licensed.
● In systems with more than one TMS2 card (HiPath 3750/HiPath 3700) these are replaced
by the same number of DIUN2 cards (HiPath 3800). If not, manual corrections are neces-
sary.
● TMOM (HiPath 3750/HiPath 3700) is not incorporated.
P31003-H3560-S100-3-7620, 03/06
9-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
exup.fm
Expanding and Upgrading HiPath 3000
Converting the customer database when changing a system
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 9-37
exup.fm
P31003-H3560-S100-3-7620, 03/06
9-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Overview
10 Workpoint Clients
10.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
optiPoint 500, page 10-4
● optiPoint 500 Telephones, page 10-5
– optiPoint 500 entry
– optiPoint 500 economy (not for U.S.)
– optiPoint 500 basic
– optiPoint 500 standard, optiPoint 500 standard SL (For U.S. Only)
– optiPoint 500 advance
– Connection Requirements for HiPath 3000
– Connection
– Connections on the Bottom of the Telephone
– USB 1.1 Interface
– Key Programming
● optiPoint 500 Add-On Devices, page 10-17
– optiPoint key module
– optiPoint BLF
– optiPoint application module (V5.0 SMR-06 and later)
– Possible add-on device configurations
● optiPoint 500 Adapters, page 10-21
– optiPoint Analog Adapter
– optiPoint ISDN Adapter
– optiPoint Phone Adapter
– optiPoint Acoustic Adapter
– optiPoint Recorder Adapter
– Possible optiPoint Adapter Configurations
– Comparison of optiset E adapters and optiPoint 500 adapters
● Information on supplying power to optiPoint 500 add-on devices and optiPoint 500 adapt-
ers, page 10-32
● Maximum Configuration for UP0/E Workpoint Clients, Add-On Devices and Adapters,
page 10-33
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-1
wclient.fm
Workpoint Clients
Overview
Topic
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S, page 10-35
● IP Telephony (Voice over IP), page 10-37
● optiPoint 410 and optiPoint 410 S Telephones, page 10-39
– optiPoint 410 entry, optiPoint 410 entry S
– optiPoint 410 economy, optiPoint 410 economy S
– optiPoint 410 economy plus, optiPoint 410 economy plus S
– optiPoint 410 standard, optiPoint 410 standard S
– optiPoint 410 advance, optiPoint 410 advance S
● optiPoint 420 and optiPoint 420 S Telephones, page 10-49
– optiPoint 420 economy, optiPoint 420 economy S
– optiPoint 420 economy plus, optiPoint 420 economy plus S
– optiPoint 410 standard, optiPoint 410 standard S
– optiPoint 420 advance, optiPoint 420 advance S
● Connection and Startup, page 10-57
– Connections on the Bottom of the Telephone
● Key Programming, page 10-60
● optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S Add-On Devices, page
10-61
– optiPoint self labeling key module
– optiPoint 410 display module
– Possible Configurations for the Add-On Devices
● Use of optiPoint 500 Adapters, page 10-65
optiPoint 600 office, page 10-66
optiLog 4me, page 10-69
optiset E Privacy Module, page 10-70
optiPoint Accessories, page 10-71
● External AC Adapters, page 10-71
● Headsets, page 10-74
optiClient 130 V5.0, page 10-77
HiPath AP 1120, page 10-78
optiPoint WL2 professional, page 10-79
Attendant console versions, page 10-80
● optiPoint Attendant, page 10-80
● optiClient Attendant, page 10-81
Mobile Telephones for HiPath Cordless Office, page 10-86
P31003-H3560-S100-3-7620, 03/06
10-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Overview
Topic
● Gigaset S1 professional, page 10-86
● Gigaset SL1 professional, page 10-87
● Gigaset M1 professional, page 10-88
● Gigaset active M, page 10-89
● Gigaset active EX, page 10-90
● Logging Mobile Telephones On To the System, page 10-92
Analog Telephones for HiPath 3000, page 10-95
ISDN Terminals for HiPath 3000, page 10-96
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-3
wclient.fm
Workpoint Clients
optiPoint 500
The optiPoint 500 telephones described in this section are compatible with the op-
> tiset E telephones. It is possible to operate both telephone families on one UP0/E
board. You can also use telephones from the two families in mixed host-client con-
figurations (earlier called the master-slave or primary-secondary configuration).
You can find information on optiset E telephones, adapters, and add-on devices in
the Hicom 150 H V1.0/Hicom 150 E Office Rel.2.0-3.0 Service Manual (refer to
Section 1.6, “Information on the Intranet”): Electronic Documentation on Com ESY
Products).
Introduction
optiPoint 500 telephones handle the digital communication of voice and data (voice communi-
cation only for optiPoint 500 entry and optiPoint 500 economy). The three dialog keys and the
display guarantee convenient and interactive operation. Furthermore, the key lamp principle vi-
sualizes the activated functions.
With the exception of optiPoint 500 entry and optiPoint 500 economy, the optiPoint 500 tele-
phones have a USB 1.1 interface. This allows for PC-supported telephoning and Internet ac-
cess over the USB interface of a PC.
The optiPoint key module and optiPoint BLF add-on devices increase the number of function
keys available.
The different optiPoint 500 adapters allow flexible expansion of the telephone workstation. Ad-
ditional devices (such as personal computers, fax equipment, telephones, headsets) can be
connected quickly because it is easy to build them on to the bottom of the telephones (not
optiPoint 500 entry and optiPoint 500 economy) and because the adapters are plug “n” play”.
You can find information not contained in this chapter in the optiPoint 500 Service Manual.
P31003-H3560-S100-3-7620, 03/06
10-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Main features
● 8 function keys (can be modified with HiPath 3000 Manager E) with LEDs (see Section
10.2.1.10)
● Open listening
● 2 volume adjustment keys (plus/minus) and pitch
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices), no display
Consultation hold
Number redial
Message
Callback
Speed dialing
Microphone on/off
Loudspeaker
Disconnect
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-5
wclient.fm
Workpoint Clients
optiPoint 500
Main features
● 12 function keys (4 can be changed using HiPath 3000 Manager E, 8 freely programmable)
with LEDs (see Section 10.2.1.10)
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices)
Service Programmable
Number redial Programmable
Microphone on/off Programmable
Loudspeaker Programmable
Programmable
Programmable
Programmable
Disconnect
Figure 10-2 optiPoint 500 economy (not for U.S.) - Standard Key Assignment (Default)
Refer to Section 10.2.1.6 for connection requirements.
P31003-H3560-S100-3-7620, 03/06
10-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Main features
● 12 function keys (4 can be changed using HiPath 3000 Manager E, 8 freely programmable)
with LEDs (see Section 10.2.1.10)
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Interfaces and slots:
– 1 USB 1.1 interface
– 1 option bay
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
Service Programmable
Number redial Programmable
Microphone on/off Programmable
Loudspeaker Programmable
Programmable
Programmable
Programmable
Disconnect
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-7
wclient.fm
Workpoint Clients
optiPoint 500
10.2.1.4 optiPoint 500 standard, optiPoint 500 standard SL (For U.S. Only)
Note: optiPoint 500 standard and optiPoint 500 standard SL (for U.S. only) function exactly the
same on HiPath 3000 systems.
Main features
● 12 function keys (4 can be changed using HiPath 3000 Manager E, 8 freely programmable)
with LEDs (see Section 10.2.1.10)
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Interfaces and slots:
– 1 integrated USB 1.1 interface
– 1 option bay
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
10-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Service Programmable
Number redial Programmable
Microphone on/off Programmable
Loudspeaker Programmable
Programmable
Programmable
Programmable
Disconnect
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-9
wclient.fm
Workpoint Clients
optiPoint 500
Main features
● 19 function keys (4 can be changed using HiPath 3000 Manager E, 15 freely programma-
ble) with LEDs (see Section 10.2.1.10)
● Alphanumeric LCD display (swivel) with 2 lines, 24 characters each. Background lighting
that stays lit for approximately 5 s.
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Interfaces and slots:
– 1 integrated USB 1.1 interface
– 2 option bays
– 1 interface for up to 2 add-on devices
– 1 headset port (121 TR9-5)
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
10-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Service Programmable
Number redial Programmable
Microphone on/off Programmable
Loudspeaker Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Disconnect
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-11
wclient.fm
Workpoint Clients
optiPoint 500
Hardware requirements
The device can also be connected to an existing optiPoint 500 telephone (except for
> optiPoint 500 entry and optiPoint 500 economy) as a client telephone (using an op-
tiPoint Phone Adapter).
P31003-H3560-S100-3-7620, 03/06
10-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
10.2.1.7 Connection
Step Activity
1. Locate a free interface on the main distribution frame or internal distributor for con-
necting the telephone.
2. Connect the cable from the main distribution frame or internal distributor to the
wall outlet.
The maximum range for a standalone or host telephone without additional local pow-
> er supply is approximately 1000 m (3280 feet) (for J-Y (ST) 2x2x0.6, ∅ 0.6 mm).
Perform the terminal test in Section 12.3.1.9 to determine whether a local power
supply is needed for additional power (for example, in host-client configurations or
for larger ranges).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-13
wclient.fm
Workpoint Clients
optiPoint 500
These indications show that the telephone is starting up and performing a self-test. Download-
ing has finished and the telephone is ready for operation when you see the date and time on
the display.
USB interface
Option bays
(see Figure 10-10)
P31003-H3560-S100-3-7620, 03/06
10-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-15
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Caution
7 Always disconnect the line cord before connecting add-on devices to the telephone.
Refer to the HiPath 3000/5000 Feature Description for model-specific data for the optiPoint key
module and the optiPoint BLF.
The following sections contain information on the possible configurations of key modules:
● Section 10.2.2.4 for terminals in the optiPoint 500 family
● Section 10.3.6.3 for terminals in the optiPoint 410 and optiPoint 420 family
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-17
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-19
wclient.fm
Workpoint Clients
optiPoint 500
An external power supply unit is always required to operate the optiPoint application module.
The power supply units for optiPoint 410 and optiPoint 420 described in Section 10.7.1.2 are
used. If you already have this type of power supply unit, the second output can be used to pow-
er the optiPoint application module.
P31003-H3560-S100-3-7620, 03/06
10-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Caution
7 Always disconnect the line cord before connecting adapters to the telephone or re-
moving them from the telephone.
Option bays
Option bays:
● 2 x for optiPoint 500
advance (shown
here)
● 1 x for optiPoint 500
basic and optiPoint
500 standard
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-21
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
S0 interface properties
● Supports point-to-point and passive bus connections
● Wired for short passive bus configurations
● Cable lengths
– Maximum 100 m (328 feet) with a cable impedance of 75 ohms
– Maximum 200 m (656 feet) with a cable impedance of 150 ohms (complies with
CCITT recommendation I.430)
● The NT terminating resistors are integrated into the ISDN adapter.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-23
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
2 4
Host Client
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-25
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
● Ring, alarm and key tones are transferred to the internal loudspeaker and not to an external
loudspeaker connected to the optiPoint acoustic adapter.
● The volume keys on the optiPoint terminal are used to adjust the volume level of the inter-
nal loudspeaker and any connected external loudspeaker. The volume of the external loud-
speaker can also be adjusted using the external amplifier.
Pin Signal
1 sense lead
2 NF+
Y cable
3 Free
4 GND
loudspeaker
Internal resistance: 0 Ω; 10 µF
Level (for PCM -20 dBm): -4.8 dBm (at volume level 8; 0.775
acoustic adapter V = 0 dBm)
Sense lead to GND: int. loudspeaker deactivated; only active
for tone ringing.
4 1
Pin Signal
1 +5V
microphone 2 GND
3 Free
4 sense lead
Input level -50 dBm: -12 dBm PCM signal
Input resistance: 150 kΩ parallel to 220 nF in series with 36
kΩ
Sense lead to GND: internal microphone deactivated.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-27
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
10-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Pin Signal
1 Tx–
2 Rx
3 Rx 4 1
4 Tx+
Pin Signal
1 Free
2 NF
3 NF 6 1
4 NF
5 NF
6 Free
Contacts 2+3 and 4+5 are bridged
internally.
Recorders to be connected must meet the following electrical re-
quirements:
Input impedance: >10 kΩ
Frequency progression: 300 to 3000 Hz ± 3 dB
Beep tone level: -26 dBm to -18 dBm at a 600 Ω load
Max. input level: 650 mVeff from a 600 Ω source
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-29
wclient.fm
Workpoint Clients
optiPoint 500
Adapter categories
Each UP0/E port in the system provides two B channels. This means that you can connect two
telephones, each with a separate phone number, to one UP0/E port.
Category 1 optiPoint 500 adapters
The following adapters each require a B channel and, therefore, can only be used once on a
host terminal (host terminal requires the second B channel of the UP0/Eport).
● optiPoint Analog Adapter
● optiPoint ISDN Adapter
● optiPoint Phone Adapter
If one of these adapters is used in the optiPoint 500 advance, only a category 2 adapter can be
operated in the second slot.
Category 2 optiPoint 500 adapters
The following adapters can be used on the host and client telephones. This is also true if a cat-
egory 1 optiPoint 500 adapter is already connected.
● optiPoint Acoustic Adapter
● optiPoint Recorder Adapter
Configuration restrictions
The voltage feed test can be used to check whether a local power supply is also nec-
> essary for an adapter configuration. To avoid any doubts, the test should always be
implemented when installing large configurations.
P31003-H3560-S100-3-7620, 03/06
10-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-31
wclient.fm
Workpoint Clients
optiPoint 500
optiPoint 500 add-on devices Is an additional external power Plug-in power supply
optiPoint 500 adapters supply required? unit connection
optiPoint key module generally not required1 series-connected2
optiPoint BLF required connected directly3
optiPoint Analog Adapter required series-connected2
optiPoint ISDN Adapter generally not required1 series-connected2
optiPoint Phone Adapter generally not required1 series-connected2
optiPoint Acoustic Adapter required4 series-connected2
optiPoint Recorder Adapter generally not required1 series-connected2
1 It is assumed that only one key module or adapter is implemented on each optiPoint 500 telephone. An additional external
power supply may be required if several key modules and adapters are implemented on an optiPoint 500 telephone or the
maximum UP0/E interface range is reached by the optiPoint 500 telephone. The telephone test described in
Section 12.3.1.9 will establish whether or not additional power is required from a local power supply.
2 The local power supply is series-connected to the optiPoint 500 telephone: the “digital” RJ6 jack on the local power supply
must be connected to the optiPoint 500 telephone. The other RJ6 jack must be connected to the UP0/E interface on the
system.
3 The local power supply is connected directly to the optiPoint BLF: one of the two RJ6 jacks on the local power supply unit
must be connected with the center jack (indicated by the symbol of a power supply unit) on the optiPoint BLF. A local power
supply can supply a maximum of two optiPoint BLFs.
4 An additional external power supply is required if the floating contacts on the optiPoint acoustic adapters are being used.
P31003-H3560-S100-3-7620, 03/06
10-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 500
Table 10-5 System-Specific Maximum Configuration for UP0/E Workpoint Clients, Add-On
Devices, and Adapters
Workpoint Clients, Add-On Devic- SYSTEM
es, Adapters HiPath HiPath HiPath HiPath HiPath HiPath
38001 3750 3550 3500 3350 3300
HiPath
3700
optiPoint 500 telephones
● Number per system 384 250/3842 723 484 245 246
● Number per box (the value in 192 144 – – – –
brackets applies to operation us- (120)
ing a PSUI)
optiPoint acoustic adapters
Number per system No restriction
optiPoint analog adapters
Number per system 116 1167 248 248 89 89
optiPoint recorder adapters
Number per system No restriction
optiPoint ISDN adapters
Number per system 116 1167 488 488 89 89
optiPoint phone adapters
Number per system 116 1167 488 488 249 249
optiPoint key modules
Number per system 100 100 100 100 30 30
optiPoint BLF:
Number per system 12 12 6 6 – –
optiset E telephones
● Number per system 384 250/3842 723 484 245 246
● Number per box (the value in 192 144 – – – –
brackets applies to operation us- (120)
ing a PSUI)
optiset E analog adapters
Number per system 116 1167 248 248 89 89
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-33
wclient.fm
Workpoint Clients
optiPoint 500
Table 10-5 System-Specific Maximum Configuration for UP0/E Workpoint Clients, Add-On
Devices, and Adapters
Workpoint Clients, Add-On Devic- SYSTEM
es, Adapters HiPath HiPath HiPath HiPath HiPath HiPath
38001 3750 3550 3500 3350 3300
HiPath
3700
optiset E control adapters
Number per system No restriction
optiset E data adapters
Number per system 50 50 48 48 16 16
optiset E speech adapters
Number per system No restriction
optiset E privacy modules
Number per system No restriction
optiset E ISDN adapters
Number per system 116 1167 488 488 89 89
optiset E phone adapters
Number per system 116 1167 488 488 249 249
optiset E key modules
Number per system 100 100 100 100 30 30
optiset E BLFs
Number per system 12 12 6 6 – –
1 Testing is not required on stations and lines up to the maximum configuration. Configurations that contain UCD/ACD or
more than one SLCN or groups with more than 10 stations should always be checked using the project planning tool (in-
tranet: http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index_en.htm).
2 Depending on the system configuration and performance, the specified capacity limits may not always be achieved. To
ensure that the dynamic capacity limit of HiPath 3750 or HiPath 3700 is not exceeded, the configuration can be tested
using the project planning tool (intranet: http://intranet.mch4.siemens.de/syseng/perfeng/tools/hpt/index_en.htm). Testing
is not required for configurations of up to 250 stations and 90 lines. Configurations that contain UCD/ACD or more than
one SLC16N or groups with more than ten stations should always be checked using the project planning tool.
3 8xUP0/E at the central board + 5xSLU8 + 1xSLMO24.
4 8xUP0/E at the central board + 5xSLU8R.
5 8xUP0/E at the central board + 2xSLU8.
6 8xUP0/E at the central board + 2xSLU8R.
7 The total number of UP0/E stations and additional stations connected using an adapter is limited to 384.
8 If the total number of UP0/E stations, analog stations and additional stations connected using an adapter is greater than
72, an external EPSU2 power supply unit must be used.
9 If the total number of UP0/E stations and additional stations connected using an adapter is greater than 24, a UPSC-D/
UPSC-DR must be used.
P31003-H3560-S100-3-7620, 03/06
10-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
10.3 optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Introduction
The IP telephones in the optiPoint 410/optiPoint 410 S and optiPoint 420/optiPoint 420 S fam-
ilies allow users to conduct telephone calls in the simple, familiar way over a data network.
The three dialog keys and the display guarantee convenient and interactive operation (not avail-
able for optiPoint 410 entry and optiPoint 410 entry S). Furthermore, the key lamp principle vi-
sualizes the activated functions.
The difference between the optiPoint 410/optiPoint 410 S and optiPoint 420/optiPoint 420 S
families lies in the design of the function key panels:
● optiPoint 410/optiPoint 410 S families: the function keys have panels with labeling strips on
which the function or call number currently saved can be entered.
● optiPoint 420/optiPoint 420 S families: the function keys are self-labeling keys. Self-label-
ing means that each key is assigned a display (1 line with 12 characters) in which the func-
tion or call number currently saved is shown.
The optiPoint self labeling key module allows you to increase the number of function keys avail-
able for the telephone types standard and advance. The add-on devices optiPoint key module
and optiPoint BLF can be used with the optiPoint 410/optiPoint 410 S and optiPoint 420/opti-
Point 420 S families.
The optiPoint 410 display module is used as an add-on device for telephone types standard
and advance. Its graphical LCD display (320 x 240 dots), the touchscreen and the navigation
keys mean that many functions can be used intuitively and therefore more effectively.
The use of different optiPoint 500 adapters guarantees flexibility for the expansion of the tele-
phone workstation (not for telephone types entry, economy, and economy plus).
Differences between the optiPoint 410/optiPoint 420 and optiPoint 410 S/optiPoint 420 S fami-
lies:
● optiPoint 410/optiPoint 420 families: All HiPath 3000/5000 features that are offered interac-
tively on the display, in the service menu, and on function keys are available (except for Re-
locate).
● optiPoint 410 S/optiPoint 420 S families: The corresponding telephones support the SIP
(Session Initiation Protocol) protocol. The SIP protocol is an ASCII based signal protocol
that is used to set up sessions in an IP network. The following features are available with
HiPath 3000/5000 V6.0:
– Hold
– Consultation hold
– Toggle
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-35
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
– Call deflection
– Screened transfer
– Mute
– Music on hold
– List of answered calls
– Number redial
– Speed dialing
P31003-H3560-S100-3-7620, 03/06
10-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Introduction
Voice over IP (VoIP) allows voice data to be transferred over IP networks. To guarantee com-
munication between the IP telephones, they must have compatible IP communication stacks.
H.323 is the universal standard that defines the framework for Voice over IP communication
and, consequently, for the IP communication stack. Additional standards are implemented as
well.
Gateways are required for communication between IP-supported networks (LAN, Intranet, In-
ternet) and circuit-switched networks (ISDN, PSTN). A gateway is not required for “straightfor-
ward” Voice over IP communication.
The tasks performed by a gatekeeper include:
● registration of IP workpoint clients:
– system clients, such as, optiClient 130 V5.0, optiPoint 400, optiPoint 410, optiPoint
420, optiPoint 600 (CorNet IP mode)
– H.323 clients, such as Microsoft Windows NetMeeting
– SIP clients, such as optiPoint 410 S, optiPoint 420 S
● setup of a connection
● access control
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-37
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
The division of HG 1500 resources into signaling and payload resources is a key feature in
version 5.0.
● Signaling Resources
These include all of the node-specific signaling data required for Voice over IP for IP-sup-
ported (LAN, Intranet, Internet) and circuit-switched networks (ISDN, PSTN). These re-
sources are provided centrally by a single HG 1500 board, the signaling gateway (= gate-
keeper HG 1500). The number of HG 1500 boards of the node is irrelevant. A HG 1500
board is defined as HG 1500 gatekeeper using HiPath 3000 Manager E.
● Payload Resources
The node resources required for the gateway transfer (between IP-supported and circuit-
switched networks) of VoIP voice data (payload) are provided by the media gateways (=
gateway HG 1500). This can be one or more HG 1500 board(s).
No payload resources are required for direct transfer between IP-supported networks. A
HiPath 5000 with HiPath ComScendo Service can function as the VoIP system.
In systems with just one HG 1500 board, this board functions both as a signaling gateway and
a media gateway. A “Release gateway resources” flag must be activated for this in HiPath 3000
Manager E. Otherwise no resources can be assigned.
In systems with multiple HG 1500 boards, the payload resources are controlled by the central
node Resource Manager. This is a self-configuring service. The signaling resources are pro-
vided centrally by the first HG 1500 board. This signaling gateway also accesses other media
gateway resources (CODECs, B channels) and signaling data (for example RTP, RTCP). This
gives IP workpoint clients and other gateways access to central payload resources of all
HG 1500 boards in a node.
Resources for functions which are not based on H.323 (for example, routing channels, vCAPI
channels), are provided as before by each HG 1500 board. In systems with multiple HG 1500
boards, the resources are provided solely by the media gateways for performance reasons.
P31003-H3560-S100-3-7620, 03/06
10-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 3rd party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 8 function keys with LEDs
● 2 volume adjustment keys (plus/minus) and pitch
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices), no display
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-39
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 410 entry, optiPoint 410 entry S
Figure 10-18 optiPoint 410 entry, optiPoint 410 entry S - Standard Key Assignment (Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 3rd party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 12 function keys with LEDs
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-41
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 410 economy, optiPoint 410 economy S
Figure 10-19 optiPoint 410 economy, optiPoint 410 economy S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 12 function keys with LEDs
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-43
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Figure 10-20 optiPoint 410 economy plus, optiPoint 410 economy plus S - Standard Key As-
signment (Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 12 function keys with LEDs
● Alphanumeric LCD swivel display with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Modularity:
– 2 option bays
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-45
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 410 standard, optiPoint 410 standard S
Figure 10-21 optiPoint 410 standard, optiPoint 410 standard S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 1 integrated USB 1.1 interface
● 19 function keys with LEDs
● Graphic display (swivel) with 4 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Modularity:
– 1 option bay
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-47
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 410 advance, optiPoint 410 advance S
Figure 10-22 optiPoint 410 advance, optiPoint 410 advance S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 12 function keys with LEDs and self-labeling keys
● Graphic display (swivel) with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-49
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 420 economy, optiPoint 420 economy S
Figure 10-23 optiPoint 420 economy, optiPoint 420 economy S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 12 function keys with LEDs and self-labeling keys
● Graphic display (swivel) with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Open listening
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch and display contrast
● Suitable for wall mounting
● No modularity (no connecting capability for adapters or add-on devices)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-51
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Figure 10-24 optiPoint 420 economy plus, optiPoint 420 economy plus S - Standard Key As-
signment (Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 12 function keys with LEDs and self-labeling keys
● Graphic display (swivel) with 2 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Modularity:
– 2 option bays
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-53
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 420 standard, optiPoint 420 standard S
Figure 10-25 optiPoint 420 standard, optiPoint 420 standard S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Protocols
– H.323, HFA/V3 + V4, CorNet IP, SIP
– HTTP, DHCP, SNMP, FTP
– H.235 (security)
– QoS to DIFFSERV and IEEE 802.1 p/Q
● Voice compression G.711, G.722, G.723 and G.729 A/B
● Power over LAN (in accordance with Cisco and standard pre802.3af)
● CTI (for example, via TAPI 1st Party)
● 1 Ethernet (10/100BaseT) interface (self-configuring) for LAN connection
● 1 Ethernet (10/100BaseT) interface (self-configuring) for the PC connection
● 1 integrated USB 1.1 interface
● 18 function keys with LEDs and self-labeling keys
● Graphic display (swivel) with 4 lines, 24 characters each
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● Port for headset (121 TR 9-5)
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Modularity:
– 1 option bay
– 1 interface for up to 2 add-on devices
● Suitable for wall mounting
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-55
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Standard key assignment (default) for optiPoint 420 advance, optiPoint 420 advance S
Figure 10-26 optiPoint 420 advance, optiPoint 420 advance S - Standard Key Assignment
(Default)
Refer to Section 10.3.4 for information on connection and startup.
P31003-H3560-S100-3-7620, 03/06
10-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Download
The manuals and tools referred to in this document are available for download at http://www.si-
emens.com/hipath (–> Downloads).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-57
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Figure 10-27 optiPoint 410, optiPoint 420, optiPoint 410 S, optiPoint 420 S - Connection Op-
tions
P31003-H3560-S100-3-7620, 03/06
10-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Table 10-6 optiPoint 410, optiPoint 420, optiPoint 410 S, optiPoint 420 S - Description of
Connections
No. Connection
1 Ethernet (10/100BaseT) interface (self-configuring) for the LAN
2 Handset
3 Local power supply (optional)1
4 Add-on device
5 Ethernet (10/100BaseT) interface (self-configuring) for the PC
6 Headset (121 TR 9-5)
7 Adapter 1
8 Adapter 2
9 USB interface
1 No local power supply is required if power is provided via the Ethernet cable (Power over LAN).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-59
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
P31003-H3560-S100-3-7620, 03/06
10-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
10.3.6 optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Add-On Devices
Caution
7 Always disconnect the line cord before connecting add-on devices to the telephone.
The user usually installs the add-on devices. The installation instructions are on the “Electronic
Operating Instructions” CD.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-61
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Main features
● Graphical user interface
● Local personal telephone directory
● Access to company-wide telephone directory via LDAP
● WAP browser
● Voice-controlled dialing
● Call list containing all incoming and outgoing calls
● Speed-dialing list
● Online help
P31003-H3560-S100-3-7620, 03/06
10-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
Connection
The optiPoint 410 display module must always be installed as the first add-on device, in other
words, connected directly to the telephone.
The connection to the telephone is made over an interface cable with the following connectors:
input MW6, output MW8. The power supply is ensured via the connected telephone.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-63
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
P31003-H3560-S100-3-7620, 03/06
10-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-65
wclient.fm
Workpoint Clients
optiPoint 600 office
Main features
● 19 function keys with LEDs
● Graphic LCD display (swivel) with 8 lines, each with 24 characters, touchscreen. Back-
ground lighting with approximately 5 s ghosting.
● 3 dialog keys for interactive user prompts: “Yes”, “Back”, and “Next”
● Full-duplex speakerphone mode with echo suppression for room adaptation
● 2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast
● Interfaces and slots:
– 1 integrated USB 1.1 interface
– 1 option bay
– 1 interface for up to 2 add-on devices
– 1 headset port (121 TR9-5)
● Suitable for wall mounting
● In UP0/E mode (UP0/E interface): SW download via PPP
● In CorNet IP mode (IP interface, 10/100BaseT): WAP access
Supported standards: H.323, Hicom Feature Access, G.711, G.723.1, QoS, SNMP, HTTP,
DHCP, FTP, LDAP (database access I/F)
P31003-H3560-S100-3-7620, 03/06
10-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint 600 office
Service Programmable
Number redial Programmable
Microphone on/off Programmable
Loudspeaker Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Disconnect
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-67
wclient.fm
Workpoint Clients
optiPoint 600 office
P31003-H3560-S100-3-7620, 03/06
10-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiLog 4me
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-69
wclient.fm
Workpoint Clients
optiset E Privacy Module
The optiset E privacy module may be subject to import and export regulations.
>
P31003-H3560-S100-3-7620, 03/06
10-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint Accessories
10.7.1.1 Local Power Supply for optiset E, optiPoint 500 and optiPoint 600 office
You can connect a local power supply to the line cords of a host or client telephone using two
MW6 jacks and the connection cable supplied (see Figure 10-32).
Variants
● Local power supply, Euro: AUL:06D1284 (C39280-Z4-C71 = number entered on unit)
● Local power supply, UK: AUL:06D1287 (C39280-Z4-C72 = number entered on unit)
● Local power supply, 110 V USA: AUL:51A4827 (C39280-Z4-C73 = number entered on
unit)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-71
wclient.fm
Workpoint Clients
optiPoint Accessories
Table 10-9 Pin Assignments of the Local Power Supply AUL:06D1284 (Euro)
Pin Assignment
1 Not used
2 –
3 a-Wire (Tip)
4 b-Wire (Ring)
5 +
6 Not used
AC Adapter
jack Analog
“MW” tele-
“digital” phone or
jack device
HiPath 3750
From optiPoint 500 adapter
(for example, here the
optiPoint analog adapter)
optiPoint 500
Telephone
P31003-H3560-S100-3-7620, 03/06
10-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint Accessories
10.7.1.2 AC Adapter for optiPoint 410 / optiPoint 410 S and optiPoint 420 / optiPoint
420 S
The AC adapter features two MW6 connectors. Power is supplied to a telephone via the left
board marked “Digital”.
Variants
● AC adapter, Euro: C39280-Z4-C510
● AC adapter, UK: C39280-Z4-C512
● AC adapter, 110 V USA: C39280-Z4-C511
Technical Specifications
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-73
wclient.fm
Workpoint Clients
optiPoint Accessories
10.7.2 Headsets
A headset replaces the telephone handset, which means that the user’s hands are free when
telephoning. The use of a cordless headset (121 TR 9-5) is also possible.
Note: A headset key can be configured for optiPoint or optiset E telephones. This allows the
user to take calls and to toggle between the handset and the headset.
P31003-H3560-S100-3-7620, 03/06
10-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint Accessories
Connection options
optiPoint and optiset E telephones not included in the table below do not support headset con-
nection.
Table 10-10 Connection Options for Corded and Cordless Headsets
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-75
wclient.fm
Workpoint Clients
optiPoint Accessories
P31003-H3560-S100-3-7620, 03/06
10-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiClient 130 V5.0
Definition
The optiClient 130 V5.0 is a PC-based multimedia application that offers connection services
for different communication media over a LAN (network). Voice, video, or chat connections can
be managed and controlled using the optiClient 130 V5.0. For voice connections, this means
that the optiClient 130 V5.0 can be used on a PC like a telephone.
Modular structure
The optiClient 130 V5.0 has a modular structure for the functional elements which can be ex-
tended or replaced to change the scope of functions available.
● The basic module of the optiClient 130 V5.0 is the main bar. The main bar does not provide
any communication functions itself, but instead serves as a central component that works
together with the various modules to define the communication functions and display of the
optiClient 130 V5.0.
● Interface modules are the modules that allow the available functions to be operated in win-
dows and dialogs. Examples of interface modules are: telephone windows, directories, call
list management, etc.
● Provider modules determine which communication systems or communication service pro-
viders the optiClient 130 V5.0 can be connected to.
● Manager modules run in the background and are not visible. They assume general com-
munication control functions. Examples of manager modules include the Keyboard Man-
ager and ScreenSaver Manager.
PC Prerequisites
● Operating system Windows®2000 (SP 4 or later) or Windows®XP (SP 1 or later)
● Processor: 1 GHz or higher recommended
● RAM memory: At least 512 MB
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-77
wclient.fm
Workpoint Clients
HiPath AP 1120
Connections
● Ethernet connections:
– 1 x RJ45: 10/100 BaseT Ethernet access
– 1 x RJ45: 10/100 BaseT Ethernet access/power supply over MDI, IEEE 802.3af (Pow-
er over LAN)
● Analog connections:
– 2 x RJ11: analog telephone, fax
● Power supply:
– External 24 Vdc/12 W local power supply
No local power supply is required if power is provided via Ethernet access (Power over
LAN).
P31003-H3560-S100-3-7620, 03/06
10-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
optiPoint WL2 professional
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-79
wclient.fm
Workpoint Clients
Attendant console versions
Figure 10-35 optiPoint 500 standard - Standard Key Assignment (Default) for optiPoint At-
tendant
For more information, please refer to the optiPoint Attendant operating instructions (see
Section 1.6, “Information on the Intranet”: Electronic Documentation on Com ESY Products).
P31003-H3560-S100-3-7620, 03/06
10-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Attendant console versions
Introduction
optiClient Attendant is a PC-based attendant console for HiPath 3000/5000, which can be used
up to six times per system.
The optiClient Attendant can also be operated as a central attendant console in a HiPath 3000/
5000 network.
The new version 7.0 replaces the previous optiClient Attendant V6.0 for all connection types
((V.24, USB and TCP/IP).
HiPath 3000/5000 V6.0 supports optiClient Attendant Version 7.0 or later. It is not possible to
use earlier versions of optiClient Attendant.
Main functions
● Display of queued calls with type, name and telephone number
● Acoustic message signaling with volume control
● Display of the switching state of source and target
● Answering of pending calls
● Selection of telephone directories:
– Outlook Contacts
– HiPath telephone directory
– Internal Attendant telephone directory, based on Microsoft Access
– LDAP on Microsoft Active Directory Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-81
wclient.fm
Workpoint Clients
Attendant console versions
P31003-H3560-S100-3-7620, 03/06
10-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Attendant console versions
Model-specific data
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-83
wclient.fm
Workpoint Clients
Attendant console versions
System requirements
If the licensing components - Customer License Agent (CLA) and Customer License
> Manager (CLM) - are to be installed on the same PC, their system requirements are
also to be taken into account.
● Pentium III 750 MHz or higher
● Min. 128 MB RAM (memory)
● Graphics resolution min. 1024 x 768 pixels
● Sound card with speaker for ringer signaling
In the case of Windows®2000, the following configuration must be carried out for signaling
via the sound card: SelectStart/Settings/Control Panel/Sounds and Multi-
media/Sounds and activate “Only use preferred devices”.
● Microsoft-compatible mouse
● CD-ROM or DVD drive
● Min. 40 MB free hard disk memory
● Windows®2000 or Windows®XP operating system
● For operation with a TCP/IP connection: Functional operating system with network and
sound card configured
● For operation on USB: optiPoint 500 telephone or optiPoint 600 office with free USB inter-
face, USB cable (part number S30267-Z360-A30-1), USB driver (Call-Bridge TU software)
and a free USB port on the PC.
● For operation using optiset E control adapters: optiset E telephone with free adapter slot
and a free port on the PC (COM port 1-4).
P31003-H3560-S100-3-7620, 03/06
10-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Attendant console versions
Licensing
A license is required for optiClient Attendant V7.0. The product is licensed centrally via HiPath
License Management.
Information on the licensing procedure can be found in Section 8.5.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-85
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Technical Specifications
● Ranges:
– Outdoors: up to 300 m
– Indoors: up to 50 m
● Operating times:
– Standby: up to 170 hours
– Talk time: up to 13 hours
● Dimensions (L × W × D in mm): 147 × 54 × 26
● Weight (including battery cells): approx. 130 g
P31003-H3560-S100-3-7620, 03/06
10-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Technical Specifications
● Ranges:
– Outdoors: up to 300 m
– Indoors: up to 50 m
● Operating times:
– Standby: up to 250 hours
– Talk time: up to 15 hours
● Dimensions (L × W × D in mm): 114 × 47 × 22
● Weight (including battery cells): approx. 100 g
● Operating temperature (mobile telephone): +5 °C to +45 °C (41 °F to 113 °F)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-87
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Main Features
● Housing:
– Spray-resistant (IEC 529 IP64)
– Dustproof
– Break- and shockproof
– Silicon-free interface
– Sturdy carry clip
● Interference resistance conforming to EN 50 082-2 (industry standard)
● Acoustics optimized for industrial environments
P31003-H3560-S100-3-7620, 03/06
10-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Technical Specifications
● Ranges:
– Outdoors: up to 300 m
– Indoors: up to 50 m
● Operating times:
– Standby: up to 250 hours
– Talk time: up to 15 hours
● Dimensions (L × W × D in mm): 150 × 57 × 25
● Weight (including battery cells): approx. 141 g
● Operating temperature (mobile telephone): –10 °C to +55 °C (14 °F to 131 °F)
Main Features
● Housing:
– Spray-resistant (IEC 529 IP64)
– Dustproof
– Break- and shockproof
– Modified key layout (for use with protective gloves)
– Illuminated display
– Silicon-free interface
– Sturdy carry clip
● Interference resistance conforming to EN 50 082-2 (industry standard)
● Acoustics optimized for industrial environments
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-89
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Technical Specifications
● Ranges:
– Outdoors: up to 300 m
– Indoors: up to 50 m
● Operating times:
– Standby: up to 250 hours
– Talk time: up to 15 hours
● Dimensions (L × W × D in mm): 150 × 57 × 27
● Weight (including battery cells): approx. 141 g
● Operating temperature (mobile telephone): –10 °C to +55 °C (14 °F to 131 °F)
Main Features
● Housing:
– Explosion protection in accordance with EN 50 014 and EN 50 020 with T4 classifica-
tion (II 2G EEx ib IIC T4)
– Spray-resistant (IP64)
– Dustproof
– Break- and shockproof
– Modified key layout (for use with protective gloves)
– Silicon-free interface
– Sturdy carry clip
● Interference resistance conforming to EN 50 082-2 (industry standard)
● Acoustics optimized for industrial environments
P31003-H3560-S100-3-7620, 03/06
10-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Technical Specifications
● Ranges:
– Outdoors: up to 300 m
– Indoors: up to 50 m
● Operating times:
– Standby: up to 70 hours
– Talk time: up to 7 hours
● Dimensions (L × W × D in mm): 160 × 55 × 25
● Weight (including battery cells): approx. 160 g
● Operating temperature (mobile telephone): –10 °C to +40 °C (14 °F to 104 °F)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-91
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
Introduction
Sixteen mobile telephones are released for use by entering the HiPath cordless system number
(DECT identification, 8 hexadecimal places) and inserting the SLC16N in HiPath 3750, HiPath
3700, or HiPath 3550, after which they can be logged on (mobile telephone codes, or PINs, are
assigned). Other mobile telephones must be released before they can be used.
For initial installation of the HiPath Cordless Office, the HiPath cordless system num-
> ber must be ordered together with the SLC16N board. Replacement boards are al-
ways delivered without a HiPath cordless system number.
Before logging on a mobile phone, you must open the login window from a system telephone
(Assistant T) by entering the code and password. A maximum of 10 login windows can be open
at a time.
Then type the station numbers of the mobile telephones you want to log on.
P31003-H3560-S100-3-7620, 03/06
10-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
After logging on and releasing a handset, always turn on the out-of-range warning signal. For
more information, refer to the operating instructions (see Section 1.6, “Information on the Intra-
net”: Electronic Documentation on Com ESY Products).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-93
wclient.fm
Workpoint Clients
Mobile Telephones for HiPath Cordless Office
When you replace a mobile telephone, the station must be assigned a new mobile
> telephone code (PIN) in the HiPath 3000system. This automatically logs off the mo-
bile telephone.
This also prevents a person who knows the old PIN to log on an invalid mobile tele-
phone.
P31003-H3560-S100-3-7620, 03/06
10-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
wclient.fm
Workpoint Clients
Analog Telephones for HiPath 3000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 10-95
wclient.fm
Workpoint Clients
ISDN Terminals for HiPath 3000
P31003-H3560-S100-3-7620, 03/06
10-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Overview
11.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Introduction, page 11-2
System Configuration, page 11-3
Technical Data for Base Stations, page 11-4
Power-Related Capacity Limits, page 11-6
Multi-SLC and System-Wide Networking, page 11-10
Planning Notes for Networked HiPath 3000 Systems Featuring Network-Wide Roaming, page
11-12
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-1
cordless.fm
11.2 Introduction
For HiPath 3000 V1.2 and later, HiPath Cordless Office can be used on all systems of this prod-
uct line.
Direct connection
The BS3/1 (S30807-H5482-X) and BS4 (S30807-U5491-X) base stations can be connected di-
rectly to the UP0/E interfaces on the central control boards in the HiPath 3550, HiPath 3350, Hi-
Path 3500, and HiPath 3300. The connection must be made via one UP0/E interface each. A
mix of base stations of types BS3/1 and BS4 is supported.
A BS3/S (X30807-X5482-X100) single-cell base station can be used to ensure the operation of
a maximum of one base station at the UP0/E interfaces on central control boards in the HiPath
3550, HiPath 3350, HiPath 3500, and HiPath 3300. In this case, it is not possible to expand with
additional base stations.
However, base stations cannot be simultaneously connected to the SLC16N board and the
CBCC within one HiPath 3550 system.
P31003-H3560-S100-3-7620, 03/06
11-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
System Configuration
Max. Simultaneous
trunk access
tions BS with connection via
to system
no. calls per BS
Max. no.
System
Analog
1xUP0/E
MTs
SLC16N
BS3/S
BS3/S
BS3/1
BS2/2
BS3/3
BS3/1
BS2/2
BS3/3
SLCN
BS4
BS4
– – CMS – 1 – – – – 2 – – – 8 No
HiPath 3350
– – CMA – 1 – – – – 4 – – – 8 Yes
HiPath 3300
– – CMA 3 – – – 3 4 – – – 4 16 Yes
– – CMS – 1 – – – – 2 – – – 8 No
HiPath 3550
– – CMA – 1 – – – – 4 – – – 8 Yes
HiPath 3500
– – CMA 7 – – – 7 4 – – – 4 32 Yes
HiPath 3550 1 – CMS 16 – 8 8 16 4 – 8 12 12 64 Yes
HiPath 3750 250 (with 4
4 – CMS 64 – 32 32 64 4 – 8 12 12 Yes
HiPath 3700 SLC16N)1
250 (with 4
HiPath 3800 – 4 CMS 64 – 32 32 64 4 – 8 12 12 Yes
SLCN)2
Explanations:
● BS2/2 (S30807-H5471-X200) is a base station that supports a maximum of 8 calls when connected using
two UP0/E interfaces.
● BS3/1 (S30807-H5482-X): is a base station that supports a maximum of 4 calls.
● BS3/3 (S30807-H5485-X): is a base station that supports a maximum of 12 calls when connected using
three UP0/E interfaces.
● BS3/S (X30807-X5482-X100): The BS3/S single-cell base station guarantees the operation of a maximum
of one base station on the UP0/E interfaces of the central board. It is not possible to operate additional base
stations.
● BS4 (S30807-U5491-X): is a base station that supports a maximum of 12 calls when connected using three
UP0/E interfaces. In the case of a direct connection, it is only permitted to make the connection via one UP0/
E interface. The B channels in the base station BS4 require a license (see Chapter 8).
1 Up to 128 handsets are possible at an SLC16N.
2 Up to 128 MTs are possible at an SLCN.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-3
cordless.fm
P31003-H3560-S100-3-7620, 03/06
11-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Technical Data for Base Stations
Outdoor cover
A base station must be installed in a weatherproof outdoor cover to guarantee radio coverage
outdoors, for example on factory premises. The outdoor cover is suitable for mounting on walls
of buildings, roofs, and masts.
The outdoor cover S30122-X7469-X already available for BS2/2 is also used for the new base
stations BS3/1 (BS3/S), BS3/3 and BS4. The only difference is that you do not need a heater
for BS3/1 (BS3/S), BS3/3 and BS4.
Outdoor cover
with BS3/1 (BS3/S)
The Styrofoam block [1] supplied
should be used to affix the BS3/1
(BS3/S). Outdoor cover
with BS3/3
[1]
Figure 11-2 BS3/1 (BS3/S) and BS3/3 in the Outdoor Cover S30122-X7469-X
For information on the various outdoor cover mounting options, refer to the HiPath Cordless Of-
fice Service Manual.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-5
cordless.fm
P31003-H3560-S100-3-7620, 03/06
11-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Power-Related Capacity Limits
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-7
cordless.fm
Table 11-5 HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS3/1 Base Stations Connected to SLC16N and BS4 Base
Stations Connected to SLC16N
Number Maximum number of corded telephones
of BS3/1s and BS4s analog telephones
connected via
1xUP0/E to 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
SLC16N optiset E and optiPoint 500 telephones
1 66 61 57 53 48 44
2 63 59 54 50 46 41
3 60 56 52 47 43 39
4 58 53 49 45 40 36
5 55 51 47 42 38 33
6 53 48 44 40 35 31
7 50 46 41 37 33 28
8 47 43 39 34 30 26
9 45 40 36 32 27 23
10 42 38 33 29 25 20
11 40 35 31 27 22 18
12 37 33 28 24 20 15
13 34 30 26 21 17 13
14 32 27 23 19 14 10
15 29 25 20 16 12 7
16 27 22 18 13 9 5
Table 11-6 HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS2/2 Base Stations Connected to SLC16N
Number Maximum number of corded telephones
of BS2/2s analog telephones
On
SLC16N 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
optiset E and optiPoint 500 telephones
1 63 59 54 50 46 41
2 58 53 49 45 40 36
3 53 48 44 40 35 31
4 47 43 39 34 30 26
5 42 38 33 29 25 20
6 37 33 28 24 20 15
P31003-H3560-S100-3-7620, 03/06
11-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Power-Related Capacity Limits
Table 11-6 HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS2/2 Base Stations Connected to SLC16N
Number Maximum number of corded telephones
of BS2/2s
analog telephones
On
SLC16N 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
optiset E and optiPoint 500 telephones
7 32 27 23 19 14 10
8 27 22 18 13 9 5
Table 11-7 HiPath 3550- Maximum Number of Corded Telephones Depending on the
Number of BS3/3 Base Stations Connected to SLC16N and BS4 Base
Stations Connected to SLC16N
Number Maximum number of corded telephones
of BS3/3s and BS4s analog telephones
connected via
2xUP0/E to 0 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50
SLC16N optiset E and optiPoint 500 telephones
1 64 60 56 51 47 42
2 60 56 52 47 43 39
3 57 52 48 43 39 35
4 53 48 44 40 35 31
5 49 44 40 36 31 27
6 45 40 36 32 27 23
7 41 37 32 28 23 19
8 37 33 28 24 20 15
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-9
cordless.fm
Required B channels
Mobile telephone (MT) has set Required B Required B chan- Required B chan-
up a connection channels nels for the home nels for the cur-
cordless board rent-location
cordless board
In the home cordless board range 1 1 –
In the current-location Cordless 3 2 1
board range
Handover from home to home 1 1 –
cordless board
Handover from home to current-lo- 3 2 1
cation cordless board
Handover from current-location to 5 3 2
current-location cordless board (temporary) (1 for each cordless
board)
P31003-H3560-S100-3-7620, 03/06
11-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Multi-SLC and System-Wide Networking
BS = BS2/2, BS3/1 or
BS BS BS BS BS BS
BS3/3
A CorNet NQ connection is possible using S0 or S2M lines or IP networking (see HG 1500 Administration
Manual).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-11
cordless.fm
PSTN
P31003-H3560-S100-3-7620, 03/06
11-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
cordless.fm
HiPath Cordless Office
Planning Notes for Networked HiPath 3000 Systems Featuring Network-Wide Roaming
PSTN
Networking (S0, S2M, IP)
PSTN Networking
(S0, S2M, IP)
Figure 11-6 Correct DECT Configuration when Networking HiPath 3000 Systems
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 11-13
cordless.fm
P31003-H3560-S100-3-7620, 03/06
11-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Overview
12 Service
12.1 Overview
Introduction
This chapter contains information on the options available to service technicians and custom-
ers for
● performing service and maintenance work.
● recognizing and correcting errors.
Such work can be performed on site or using remote service.
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
Service and Maintenance Tasks, page 12-3:
● Backing Up the Customer Database (CDB Backup), page 12-3
● Effects of Hardware Changes on Customer Data, page 12-8
● Relocate/Transfer Application Processor Software (APS), page 12-11
● Upgrading HiPath 3000, page 12-17
● Determining System Information and Installed Software Components (HiPath Inventory
Manager), page 12-18
● Backing Up System Components (Backup Manager), page 12-19
● HiPath User Management, page 12-21
Guided Maintenance, page 12-23:
● Diagnosis Options, page 12-23
● HiPath 3000 Error Messages (Entries in the Eventlog for HiPath 3000), page 12-49
● HiPath 5000 Error Messages (Event Viewer Entries for HiPath 5000), page 12-76
Correcting Errors, page 12-89:
● Automatic Error Correction, page 12-89
● Manual Error Correction Without HiPath 3000 Manager E, page 12-89
● Manual Error Correction With HiPath 3000 Manager E, page 12-90
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-1
service.fm
Service
Overview
Topic
Remote Service, page 12-91:
● HiPath 3000 Connection Options, page 12-92
● HiPath 5000 Connection Options, page 12-93
● Remote System Administration, page 12-93
● Remote Correction of System Software (APS), page 12-94
● Remote Error Signaling, page 12-95
● Controlled Release of a Remote Connection, page 12-96
● Remote Administration and Access Using PPP, page 12-96
Security Features, page 12-98:
● Access Security, page 12-98
● Automatic Logging of Administration Procedures, page 12-105
P31003-H3560-S100-3-7620, 03/06
12-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
Definition
CDB backup refers to saving the customer database (CDB) to the multimedia card MMC (Hi-
Path 3000) or copying the cyclic RAM data and saving it in two PDS (Permanent Data Service)
files (HiPath 5000).
Note: The RUN LED flashes repeatedly for a short period to signal that a CDB backup, which
takes about 30 seconds, is in progress on the MMC.
HiPath 3000
A two-stage concept guarantees automatic customer data backup.
A complete CDB backup version can be found on the MMC at any time. Deltas for this backup
are stored in an SRAM area (with battery backup) in the central control board. If the SRAM area
is full, the customer data is automatically backed up. This means that the entire CDB, including
SRAM content, is copied from the SDRAM in the central control board to the MMC. The current
CDB is simultaneously stored on the MMC along with the “old” CDB, which is not deleted until
the current CDB is completely stored on the MMC.
In case of a power outage, the SDRAM content that has no battery backup is completely lost.
However, by re-accessing the CDB backup on the MMC, the system’s database can be restored
to the state it was in prior to the power outage.
Regardless of the volume of changes to the database, HiPath 3000 always automatically per-
forms a complete CDB backup at midnight, system-time.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-3
service.fm
Service
Service and Maintenance Tasks
HiPath 5000
On the communication server, RAM data is copied automatically every three minutes and
stored in the file hicom.pds. This file contains the complete data description of the HiPath
5000 with emulated HG 1500 boards. This includes:
● customer data
● trace
● error history
● call charge data
● status data
The directory in which the two PDS files are to be stored must be defined when the HiPath 5000
software is installed (setup). The two PDS files are created when the HiPath 5000 is started for
the first time.
The PDS files must not be modified, as reading of the files using conventional tools
> and interpretation of the content is not possible without specialist knowledge.
In the event of an error, the PDS files can be made available to the responsible Ser-
vice Support contact for diagnostic purposes. The *.trc and *.dmp files stored in
the diag subdirectory of the installation directory should also be supplied.
P31003-H3560-S100-3-7620, 03/06
12-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
Step Activity
Manual customer data backup on the MMC
1. Assistant T: Start system administration
2. Menu 28 -> Edit CDB
3. Menu 28-2 -> Back up CDB data
4. Menu 28-2-1 -> CDB on MMC
Loading the saved customer data from the MMC into the system
1. Assistant T: Start system administration
2. Menu 28 -> Edit CDB
3. Menu 28-2 -> Back up CDB data
4. Menu 28-2-2 -> CDB from MMC
Caution: When performing this action, the system performs a hard restart.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-5
service.fm
Service
Service and Maintenance Tasks
Definition
The HiPath Software Manager supports, among other things, the backup of customer databas-
es (Backup Manager) from all HiPath 3000/5000 systems in the same customer network (see
also Section 12.2.6, “Backing Up System Components (Backup Manager)”).
The CDB backups are stored in a directory which must be defined in advance. The data backup
can either be started manually immediately or performed at a predefined time. A cyclic backup,
which saves the customer data at a set time every day, is also possible.
Refer to the help provided with the HiPath Software Manager for information on backing up cus-
tomer data with this tool.
A new license file is always required if a central control board that requires a license
> has to be replaced. As a result of the replacement, the MAC address changes and
the license becomes invalid.
For information on this procedure, please see Section 8.4.7.
When replacing a central control board due to a hardware defect, for example, the following op-
tions are available for handling the CDB:
● Procedure: After replacing the board, load the “current” CDB to the system
Step Activity
1. Copy the current CDB and save it on the MMC.
2. Disconnect the system from the power supply.
3. Remove the MMC.
4. Replace the central control board.
5. Insert the MMC.
6. Restart the system by plugging in the power plug.
7. The CDB previously stored on the MMC is loaded to the system RAM. The
customer system is now configured:
● The CMI mobile telephones are logged on.
● The V.24 baud rate is set up.
● The ACD login port is configured.
● All telephone options, such as volume and display, are determined per
station.
P31003-H3560-S100-3-7620, 03/06
12-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
● Procedure: After replacing the board, load the “old” CDB from the customer disk to
the system
Step Activity
1. Back up current CDB with HiPath 3000 Manager E.
2. Disconnect the system from the power supply.
3. Remove the MMC.
4. Replace the central control board.
5. Insert the MMC.
6. Restart the system by plugging in the power plug.
7. Reload.
8. If an “older” CDB update is imported, reload the CDB into the system with-
out the Delta mode. The “hardware and CDR switch” remain inactive.
9. Reset. The customer system is now configured. All you have to do now is
● log on the CMI mobile telephones again,
● reset the V.24 baud rate,
● re-configure the ACD login port,
● redefine all telephone configurations, such as volume and display, per
station.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-7
service.fm
Service
Service and Maintenance Tasks
Caution
7 When using HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, disconnect
the system from the power supply before removing or inserting boards.
Only HiPath 3800, HiPath 3750 and HiPath 3700 peripheral boards can be removed
or inserted during operation.
If Then
Inserting new board in Board is integrated into the system according to the rules for initial
free slot startup (Page 4-156).
● System with default numbering plan
The station numbers from the new board are appended (con-
secutively and in ascending order) to the numbers already as-
signed.
● System with modified numbering plan
The station numbers on the new board can be in any order.
Using HiPath 3000 Manager E or Assistant T, you can assign a spe-
cific station to a port. If the number is already assigned to a different
object, you can switch both numbers.
Replacing board with Board is activated. The same station range is used.
same or under equipped
board type
P31003-H3560-S100-3-7620, 03/06
12-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
If Then
Replacing board with Board is activated. The old station range is activated and the ports
over-equipped board of associated with the new board are inserted at the end. The ports
same type are split if there is no contiguous station range available.
In the case of subscriber line modules, you can use HiPath 3000
Manager E to retain the old station data by copying it to the new
board, or you can delete it and reset the default state. Copying is
not possible for trunk boards.
Replacing with a differ- The system does not automatically activate the board.
ent board type After removing the old board, you can delete it from the database
using HiPath 3000 Manager E or Assistant T.
After you have inserted the new board, the system activates it as if
it had been inserted into a free slot. However, the CDB area used
by the old board is left as a gap.
In the case of subscriber line modules, you can use HiPath 3000
Manager E to retain the old station data by copying it to the new
board, or you can delete it and reset the default state. Copying is
not possible for trunk boards.
If you initiate a system reload on a system updated as described above, the system
> must be reset after the updated CDB has been installed. The reset synchronizes the
port placement sequence in the system with that of the CDB.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-9
service.fm
Service
Service and Maintenance Tasks
Step Activity
1. Disconnect system from power supply.
2. Remove the board(s).
3. Restart the system by plugging in the power plug.
4. Delete board slot using user interface (29-4).
5. Disconnect system from power supply.
6. Insert new board(s).
7. Restart the system by plugging in the power plug.
8. Load customer data from the system.
Adapt customer data to new hardware configuration. Insert new board(s), (sta-
tions, for example).
9. Load new customer data into the system.
P31003-H3560-S100-3-7620, 03/06
12-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
APS replacement/transfer is not possible with HiPath 5000. You must perform a
> complete software upgrade.
APS replacement is only possible within a version and if a logical, compatible CDB
> is available.
Procedure
Step Activity
1. Create a backup of the current CDB and save on a customer disk for security
reasons.
2. Remove MMC with “old” APS.
The flashing Run LED (0.1 s on/0.1 s off) indicates that the MMC is missing.
The system remains active for call processing.
3. Install new MMC with “new” APS.
The system creates an automatic CDB backup and thus saves the current cus-
tomer database (CDB) to the new MMC.
4. An automatic reset is then performed (hard restart for entire system with the
current CDB).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-11
service.fm
Service
Service and Maintenance Tasks
Step Activity
5. Use the “APS stamp” to verify that the new APS has been activated. Use Hi-
Path 3000 Manager E or Assistant T (menu item 29-1-2) to make the neces-
sary query.
Options
The APS Transfer feature is available with the HiPath 3000 Manager E. It facilitates
● the on-site replacement of the APS by means of a direct connection via the V.24 interface
or preferably via the integrated analog/digital modem or via LAN.
● an APS transfer via remote service from a central service center using the integrated an-
alog or digital modem or via LAN.
Function
This feature transfers the new APS in its entirety and stores it in the available area of the MMC.
After the transfer, the checksum is analyzed. The system subsequently reports whether or not
● an error was found.
If so, you have to delete the transferred APS.
● the APS transfer was successful.
You can then activate the APS immediately or at a later time.
Resetting the system initiates the changeover from the old APS to the new APS. If problems
occur during this process, the old APS is reactivated. Once the changeover is successful, the
old APS is deleted from the MMC.
In case of power outage, the SDRAM content that has no battery backup and the active APS
are completely lost. By re-accessing the current APS on the MMC, the system can be restored
to the state it was in prior to the power outage.
P31003-H3560-S100-3-7620, 03/06
12-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
Procedure
Step Activity
1. Save the existing customer data (for example: as “customer1.kds”).
2. Select “Open CDB” from the HiPath 3000 Manager E file menu and highlight
“APS files (*.fst)”.
Open the fst file using the new system software.
3. Double-click the “Transfer” icon:
Select the appropriate access and enter the PIN code.
4. Highlight “APS Transfer”. A new window appears in the top right of the screen.
You can use this window to select whether
● to change directly to the APS after the transfer is completed.
● to change to the APS at a pre-determined time.
Note: If the “APS Transfer” field has a gray background, then the fst file was
not opened correctly.
5. Start the APS transfer. Transfer time for connection via digital modem (ISDN)
or LAN is approximately 20 to 30 minutes. Connections via the IMODN analog
modem or direct connections (V.24 interface) require longer transfer times.
6. Once the APS transfer is completed, the HiPath 3000 Manager E reports that
the “APS transfer was successful”. Once the set transfer time has been
reached, the system resets and the new version is used for startup.
7. Use the “APS stamp” to verify that the new APS has been activated. Use Hi-
Path 3000 Manager E or Assistant T (menu item 29-1-2) to make the neces-
sary query.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-13
service.fm
Service
Service and Maintenance Tasks
● After a successful changeover to the new APS, an entry in the error memory is also made
and the old APS on the MMC is deactivated. This does not impede switching traffic. The
deactivated area is now available for a new APS transfer. The positive or negative entry in
the error memory is sent to the service center.
P31003-H3560-S100-3-7620, 03/06
12-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
HE620S.10.123
Production number/software binder
Feature package
Note: Service Maintenance Releases
(SMR) are identified by production num-
ber and feature package.
System: ● up to and including V4.0:
S = HiPath 3750/HiPath 3700
T = HiPath 3250/HiPath 3150
U = HiPath 3550/HiPath 3500/HiPath
3350/HiPath 3300
● V5.0 or later:
A = HiPath 5000
P = HiPath 3800
S = all HiPath 3000 systems except
HiPath 3800
Version: 600 = HiPath 3000/5000 V5.0
620 = HiPath 3000/5000 V6.0
Software: A = Manager/Assistant ...
E = System
HiPath ...
Software modifications for the correction of faults and the provision of a small num-
> ber of new features are called software updates or service maintenance releases
(SMR). A CDB conversion is not necessary.
Software upgrades are used for more extensive enhancements to the scope of ser-
vices. An upgrade may also include modifications to hardware as well as error cor-
rections. A software upgrade changes the name of the version, for example, from
V1.0 to V2.0. A CDB conversion may be necessary.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-15
service.fm
Service
Service and Maintenance Tasks
12.2.3.2 APS Transfer for HiPath 3000 Systems With HiPath Software Manager
Definition
The HiPath Software Manager supports, among other things, updates of the system software
(Upgrade Manager) of all HiPath 3000 systems in the same customer network. An update of
the software of installed HG 1500 boards (HG 1500 V3.0 SMR-3 or later) can also be per-
formed.
The following options are available under the menu item “Upgrade”:
● upgrade all HG 1500 boards and HiPath 3000 systems
● upgrade HG 1500 boards (HG 1500 V3.0 SMR-3 or later)
● upgrade all HiPath 3000 systems
Note: The file format “*.fli” must be selected for APS transfer using HiPath Software Man-
ager.
The software (APS and/or HG 1500) is updated in two steps. First, the new software is loaded
to a system memory known as the “shadow area”. This occurs in the background independently
of the system status.
In the second step, the new software version must be made available, in other words, the switch
from the current software version to the new software version must take place. The current soft-
ware is replaced by the software in the shadow area and thus deleted. The changeover can
either be started immediately once the software has been loaded or performed at a predefined
time.
Caution
7 It is important to make sure that the changeover time for a HG 1500 board does not
coincide with the changeover time for the corresponding HiPath 3000, as this can
render the HG 1500 board unfit for operation. The default setting of the HiPath Soft-
ware Manager therefore incorporates a safety margin of 10 minutes between the
changeovers.
Information about updating the system software and the HG 1500 software using HiPath Soft-
ware Manager can be obtained from the help provided with this tool.
Note: If HiPath Software Manager is not available, the HG 1500 software update must be per-
formed with HiPath 3000 Manager I (up to and including HG 1500 V2.0) or Web-based Man-
agement WBM (HG 1500 V3.0 or later).
For APS transfer using HiPath Software Manager, the HiPath 3000/5000 TFTP server must be
installed on a server in the customer LAN. All HiPath 3000 systems must be able to access this
HiPath 3000/5000 TFTP server over IP. Other TFTP servers cannot be used for HiPath Soft-
ware Manager.
P31003-H3560-S100-3-7620, 03/06
12-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-17
service.fm
Service
Service and Maintenance Tasks
Definition
HiPath Inventory Manager is a service for detecting the installed software components and sys-
tem information in a HiPath 3000/5000 network. System information is only determined upon
initial start-up of the service.
The relevant information can be displayed in table format by clicking one of the following but-
tons:
● Master Setup
Information including version and installation date of the master setup.
● HiPath 3000
Hardware and software information regarding the HiPath 3000 systems in the network and
the installed HG 1500 boards.
● HiPath Applications
Information regarding the following software components:
– MS Windows components (MS Internet Explorer, DNS server, DHCP server)
– Media Streaming
– TAPI
– CCMC, CCMS, CMD, CSP
– Administration
– HiPath 5000 Server
– GetAccount
– HiPath 3000 Manager E
– Common Software
● Operating System
Information regarding the current operating system.
All information can be updated at any time via the “Update data” button.
The system information is automatically determined when the HiPath Inventory Manager ser-
vice is started for the first time. A cyclic update can be performed every 1 days. The system
information can be queried manually at any time. This should always be done before an update/
upgrade, for example.
Further details on how to determine the system information using HiPath Inventory Manager
can be obtained from the help provided with this tool.
P31003-H3560-S100-3-7620, 03/06
12-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
Definition
The HiPath Software Manager allows the following system components and databases of a Hi-
Path 3000/5000 network to be backed up:
● Full backup (= default setting)
This option creates a data backup for all HiPath 3000 systems and HG 1500 boards in the
HiPath 3000/5000 network as well as databases (Feature Server, SQL Server).
● HG 1500 backup
This menu item displays all HG 1500 boards in the HiPath 3000/5000 network in an over-
view. It is possible to back up the data of one or all of the displayed HG 1500 board(s)
(HG 1500 V3.0 SMR-3 or later).
● HiPath 3000 backup
With this menu item, all HiPath 3000 systems in the HiPath 3000/5000 network are dis-
played in an overview. It is possible to back up the data of a specific system or of all dis-
played HiPath 3000 systems.
● Database backup
With this menu item, all databases (Feature Server, SQL Server) are displayed in an over-
view. It is possible to back up the data of one or of all database(s).
Refer to the help provided with the HiPath Software Manager for information on backup with
this tool.
Setting options
It is possible to specify individually when a backup is to take place and where the backed up
data can be stored.
● Time of data backup
The data backup can either be started manually immediately or performed at a predefined
time. By default, a full backup is performed cyclically, with the data being saved daily at a
specific time.
● Backup path
The path for the directory in which the backup files are to be stored can be specified.
● Backup to a local drive
There is no need to specify a special user account for this type of backup.
● Backup to a network drive
A user account (user name, password) with write permission for the network drive must be
specified for this type of backup.
If the backup source (for example HiPath 5000) is located on a separate PC, this user ac-
count must have read permission for the shared drive.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-19
service.fm
Service
Service and Maintenance Tasks
The backup path and the type of backup are preset for the HiPath Software Manager during
setup.
Restoring data
The HiPath Software Manager allows damaged databases to be restored with the database
backup.
The other system components are restored using HiPath 3000 Manager E (for HiPath 3000)
and HiPath 3000 Manager I (for HG 1500 up to and including V2.0) or Web-based management
WBM (for HG 1500 V3.0 or later).
P31003-H3560-S100-3-7620, 03/06
12-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Service and Maintenance Tasks
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-21
service.fm
Service
Service and Maintenance Tasks
Refer to the HiPath User Management service and administrator documentation for
> information on the installation and configuration procedures for HiPath 3000/5000
and HiPath 3000 Element Manager.
P31003-H3560-S100-3-7620, 03/06
12-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
RUN LED
A RUN LED that displays the system’s operating capacity is located on the central control
board.
Table 12-2 RUN LED - LED Status Meaning
Options available?
You can call up the following options using the HiPath 3000 Manager E:
● CMA
● CMS
● LIM
● IMODN
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-23
service.fm
Service
Guided Maintenance
● MPPI, UAM (only with HiPath 3550, HiPath 3350) or UAMR (only with HiPath 3500, HiPath
3300)
The availability of one of these Announcement and Music Modules is displayed as
“Option 5”.
The ALUM4 module cannot be displayed.
P31003-H3560-S100-3-7620, 03/06
12-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-25
service.fm
Service
Guided Maintenance
Data Contents
Date Date of the event (as stored in system)
Time Time of the event (as stored in system)
Trunk number Number of the trunk
Slot/Port Slot and port number
Status ● Trunk status:
– Inactive
– Incoming call
– Outgoing call
– Trunk-to-trunk connection
– Trunk disabled (using lockout switch or HiPath 3000 Man-
ager E)
– Trunk failure
● Number of the connected station
P31003-H3560-S100-3-7620, 03/06
12-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Data Contents
Station name Name of the selected station
Slot, port Example: 7-1
Telephone model Example: optiPoint 500 advance
Telephone status Active or inactive
DID number External number of the selected station
Language Menu language of selected station
Connection status ● Inactive: The telephone is idle.
● Busy: The telephone is off the hook, but not yet di-
aled.
● Waiting: The telephone call is in the queue.
● Connected: The telephone is connected to a second
telephone with a trunk or a hunt group member.
● Holding: The telephone is on hold.
● Error: The connection cannot be established due to
an error (for example, invalid telephone number).
● Call: The telephone is called.
Connected to The number of the connected station or trunk
Forwarding status ● Off: No call forwarding activated.
● Internal: Call forwarding activated only for internal
calls.
● External: Call forwarding activated only for external
calls.
● All: Call forwarding activated for all calls.
Destination Number of call forwarding destination
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-27
service.fm
Service
Guided Maintenance
Data Contents
Activated features Status of activated features (on or off):
● Do Not Disturb
● Call forwarding (device status)
● Answer text
● Room monitor
● Lock Code
● Suppress calling ID
● Call connection
● Disable incoming ringing
● Out of Hunt group/Group ringing
● Call waiting tone
● Direct Answering
● Call waiting terminating
● Ring transfer (only for MULAP)
● Call forwarding MULAP (only for MULAP)
Stations included List of the stations included
P31003-H3560-S100-3-7620, 03/06
12-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Special user rights are required for activating the Trace setting in the Maintenance
> menu, that are exclusively reserved by the user group Development.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-29
service.fm
Service
Guided Maintenance
This documentation does not cover interpretation of the trace window contents by
> the Trace Monitor. Trace files are used for problem analysis and are interpreted by
Service Support during servicing.
The description below can be used to determine the work steps required for Trace
Monitor navigation and control and for swapping out the trace contents to a file.
Trace messages can be displayed for the following HiPath 5000 applications:
● Feature Server
Two trace files are available:
– \winnt\system32\carlogfile.txt
provides details on which HG 1500 boards have logged on to the network and when.
– \winnt\system32\rgtracefile.txt
provides details on when the individual HG 1500 boards were assigned a station num-
ber.
● Presence Manager
Two trace files are available:
– \winnt\system32\dssdiagnosefile.txt
– \winnt\system32\dsslogfile.txt
● HiPath Manager PCM Administration
Administration of the configuration parameters for component control by the user, for gen-
eral parameters, for call charge evaluation and analysis.
● HiPath Manager PCM
Configuration of call handling and call forwarding using definable profiles.
● HiPath GetAccount
Internal component that is responsible for evaluating and saving call charges and for im-
mediate printing.
P31003-H3560-S100-3-7620, 03/06
12-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-31
service.fm
Service
Guided Maintenance
Exit
Menu bar
Workspace
(open trace win-
dows)
Status bar
P31003-H3560-S100-3-7620, 03/06
12-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
The Trace Monitor menu bar lists the available menus/menu items.
Table 12-5 Trace Monitor Menu Functions
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-33
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Procedure
1. The Write Messages to File entry should be selected via the system menu or, alternative-
ly, the context menu (right-click in the Trace window) of the relevant Trace window.
A message box containing the path and file name of the swap file for the trace window ap-
pears:
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-35
service.fm
Service
Guided Maintenance
The default destination directory for swap files is the Windows 2000 shell user directory:
C:\Documents and Settings
\[Windows User]
\My Documents
\[Application ID]
\[Trace File Name]
The following naming conventions apply to swap files:
<Application ID><Time>.trc
The time is stored in YYYYMMDDhhmm format.
P31003-H3560-S100-3-7620, 03/06
12-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-37
service.fm
Service
Guided Maintenance
If the test does not react as described, an additional power supply (plug-in power
> supply unit) for the relevant system telephone may be necessary.
The phone number, date and time are normally shown in the display. If a different text appears
(“Gateway not found”, for example), this means that there is an error.
Correct the error by following the administration instructions for the relevant telephone.
P31003-H3560-S100-3-7620, 03/06
12-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Introduction
The Event Viewer (Eventlog) is one of the tools supplied with NT-based operating systems
(Microsoft Windows NT, Microsoft Windows 2000, Microsoft Windows XP, etc.). The Event
Viewer administers logs that record information on programs, security, and system events on
the computer. You can use it to display and administer eventlogs, to gather information on hard-
ware and software problems, and to monitor security events.
You can use this standard tool to obtain status information for the HiPath 5000 server and any
application server present.
All events associated with the server(s) and its (their) applications are saved. The events pro-
vide a quick and, above all, time-specific overview of all relevant actions (status, information,
warning, error, etc.).
The tool itself handles the event entries. You can specify the length of the event file, the validity
of events in days, the reaction when the maximum size has been reached, and the display filter,
for example.
You can save the resulting event file (log file) under any name.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-39
service.fm
Service
Guided Maintenance
You can configure these areas independently of one another by marking the area and selecting
Operation/Properties:
● The maximum log size (in KB) and the reaction if this value is exceeded are defined under
“General”. 1.44 MB (= capacity of a floppy disk) is the recommended log size. “Overwrite
events where necessary” is the recommended setting.
● You can select an event source under “Filter” for example, to display only the entries for the
HiPath 5000 server. You can further restrict the output under Category and Event ID.
Evaluating events
Double-click an entry in an Event Viewer area to obtain more precise information on an event.
Use the two arrow buttons to spring from one event to the next.
The HiPath 5000 Server entries in Table 12-8 are currently supported.
P31003-H3560-S100-3-7620, 03/06
12-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Menu bar
● Program – Exit: Closes the HiPath 5000 State Viewer.
● Server
– Start: Starts the HiPath 5000 server.
– Stop: Stops the HiPath 5000 server.
● Configuration
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-41
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-43
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
SNMP functions
Simple Network Management Protocol (SNMP) represents a convenient platform within the
TCP/IP protocol family for management tasks in the HiPath 3000 and HiPath 5000 software.
SNMP is used more or less as a management agent on HiPath 3000 and HiPath 5000 and han-
dles central monitoring and administration of LAN network components, including the HiPath
3000 and HiPath 5000. It is possible to
● address the HiPath 3000 and HiPath 5000 over the TCP/IP protocol family.
● access data from external management applications such as HiPath Fault Management.
● implement remote maintenance jobs (such as online port status, disabling and enabling
ports, and determining free ports).
● transmit service-related Class B errors.
● visualize the operating status of a HiPath 3000 and HiPath 5000.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-45
service.fm
Service
Guided Maintenance
This documentation does not cover interpretation of the analysis data. Trace files,
> log files, etc. are used for problem analysis and are interpreted by Service Support
during servicing.
Log files
The Customer License Agent (CLA) manages a configuration log and error log. Both logs are
viewed using the CLM. This provides a good overview of an error situation that helps to narrow
down an error to a specific area, for example.
Trace files
The CLA records detailed information about its internal processes in a text file that is stored in
the bin subdirectory of its installation directory. The degree of detail (off, low, standard, all) and
the size (in MB) of this recorded information can be defined using the Customer License Man-
ager (CLM).
Extensive reconstruction of an error is generally made possible by setting 100 MB for the size
and a “standard” degree of detail.
P31003-H3560-S100-3-7620, 03/06
12-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
12.3.1.14 Analysis Using HiPath Software Manager and HiPath Inventory Manager
This documentation does not cover interpretation of the analysis data. Trace files,
> log files, etc. are used for problem analysis and are interpreted by Service Support
during servicing.
Trace files
The installation directory of the Common Web Service (default = C:\Program Files\sie-
mens\hipath\commonweb) contains, among other things, the Trace directory, in which the
trace files for the Web applications HiPath Software Manager and HiPath Inventory Manager
are stored.
This directory name is saved in a registry key during installation. If this key cannot be accessed,
the trace files are stored in the temporary system directory (as the Common Web Service is
started as a system service). Under MS Windows 2000, this directory normally has the name
C:\WINNT\temp, while under MS Windows 2003 it is called C:\WINDOWS\temp.
Each time a Web application is started by the Common Web Service (TomCat Web server), a
separate subdirectory is created. This subdirectory contains the trace files in XML format. The
subdirectory name follows the convention date_<DATE>_time_<TIME>.
In order to enable service support to perform diagnosis, the complete Trace directory must be
made available. Adaptations for more detailed traces can be made in consultation with service
support using the CFG files in the config directory. These adaptations refer to the degree of
detail (level) of the trace file and application options for the components of all Web applications.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-47
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
12.3.2 HiPath 3000 Error Messages (Entries in the Eventlog for HiPath
3000)
Classification
Accrued errors are classified according to error class and error number. The three different er-
ror classes are described below:
● Error Class A = Customer-related error
HiPath 3000 Manager E fails to issue a signal/message. Class A errors are indicated on
the optiPoint Attendant display. They can be corrected by the customer without service
support.
The following error messages are implemented at present:
– “Printer Alarm” (caused by paper out, for example)
– “Fan Failure” (caused by failure of the fan with HiPath 3500 or HiPath 3300)
– “Revisor Alarm” (caused by overflow of the log part of the MMC, for example).
– “Too Many Key Modules” (caused by attaching more than the maximum possible num-
ber of optiPoint key modules specified in Table 10-5)
● Error Class B = Service-related errors
Class B errors can be read out via the HiPath 3000 Manager E Event Log, which can be
automatically forwarded to a service center.
Errors of this class are, for example, failure of the boards, individual ports, or trunks. You
can generally correct these errors by replacing the hardware, re-configuring the customer
database, or by working together with the carrier. Table 12-7 lists all Class B errors.
● Error Class C = Development-related errors
HiPath 3000 Manager E fails to issue a signal/message.
Class C errors require diagnosis and problem analysis by specialists.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-49
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-51
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-53
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-55
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-57
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-59
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-61
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-63
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-65
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-67
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-69
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-71
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-73
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
12-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-75
service.fm
Service
Guided Maintenance
12.3.3 HiPath 5000 Error Messages (Event Viewer Entries for HiPath
5000)
Table 12-8 lists the possible entries for HiPath 5000 in the Event Viewer.
The Source column designates the origin of the possible entries:
● HiPath AllServe = Feature Server events
● GetAccount = GetAccount events
● PCM = HiPath Manager PCM events
The various components of these sources are identified by means of the abbreviations in the
Category column. Section 6.3 contains information about the most important components of
the Feature Server.
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-77
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-79
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-81
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-83
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-85
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-87
service.fm
Service
Guided Maintenance
Table 12-8 Event Viewer Entries for the HiPath 5000 Server
P31003-H3560-S100-3-7620, 03/06
12-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Correcting Errors
If you initiated a system reload, the system must be reset after the CDB has been
> installed. This ensures that all signaling gateways (= HG 1500 gatekeeper) are re-
set.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-89
service.fm
Service
Correcting Errors
ALUM
You cannot initiate a power failure transfer to analog telephones using HiPath 3000 Manager E.
P31003-H3560-S100-3-7620, 03/06
12-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Remote Service
Definition
Remote service is described as communication between the service center and HiPath 3000
and HiPath 5000 using the public telecommunications network to fulfill service tasks. These
tasks are
● remote system administration,
● remote administration of Plus products via the system,
● remote correction of system software (APS transfer),
● automatic signaling of error messages.
Remote service facilitates the administration and maintenance of various communication sys-
tems from a central location.
The connection to HiPath 3000 can be set up via the integrated digital modem (B channel), the
integrated analog modem (IMODN) or the HG 1500.
Special software programs, such as pcANYWHERE, facilitate connections to HiPath 5000. If
the customer agrees, Remote Access Service RAS can also be used, provided this service is
active on the HiPath 5000 server.
HiPath 3000
PSTN
(analog or
digital
Central Board telecommunica-
tions network) Service Center
Modem Service PC
with
LIM HiPath 3000 Man-
ager E
Client
LAN
Plus Products
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-91
service.fm
Service
Remote Service
Caution
7 Be sure to disconnect the system from the power supply before removing or in-
serting integrated analog modems (IMODN).
The IMODN is treated as a pseudo port. It receives a number in the system that can be
reached internally through direct internal dialing (DID). You can cancel the DID number
manually to prevent external access.
● Integrated digital modem (B Channel)
An integrated B channel modem is available with all systems in the HiPath 3000 product
line. This type of modem facilitates remote access using both digital trunks, tie trunks, as
well as S0 subscriber lines. Data transmission is supported according to Protocol X.75.
The digital modem is treated as a pseudo port. It receives a number in the system that can
be reached internally and through direct internal dialing. You can cancel the DID number
manually to prevent external access.
Baud rate settings
For information about setting the baud rate for different connection types between HiPath 3000
and HiPath 3000 Manager E, consult the Help for HiPath 3000 Manager E.
Access to the analog/digital modem
The customer must enable the access to both modems by entering a six-digit PIN code. If the
service center is to make a connection to the HiPath 3000 over a modem, it may be necessary
to enter this individual code. It depends on which trunk type is used for the modem access. The
following applies to the system default:
● Access over ISDN trunk = enable procedure: customer must enter PIN code.
● Access over another trunk = login without code: PIN code is not necessary.
If necessary, the system administration (only by using Assistant T) can reset the PIN code back
to the default value.
P31003-H3560-S100-3-7620, 03/06
12-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Remote Service
Callback
HiPath 3000 can manage up to six different callback indices (callback passwords and their rel-
evant callback numbers), in which case the first callback connection is also the destination of
the automatic error signaling. For each callback connection, you can select either the digital
modem (B channel) or the analog modem (IMODN).
If you have chosen your settings and selected the connection setup option “Callback activated”,
the HiPath 3000 Manager E can dial in to the system. HiPath 3000 registers the callback des-
tination and saves the callback index. After 10 s, the HiPath 3000 initiates the actual callback
with the number which is linked using the callback index. As soon as the connection is estab-
lished, you can use HiPath 3000 Manager E to manage the system.
If no connection is established, HiPath 3000 will make a total of 20 attempts in intervals of 10 s
after which the callback attempt ends and has to be started up again with HiPath 3000 Manager
E.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-93
service.fm
Service
Remote Service
P31003-H3560-S100-3-7620, 03/06
12-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Remote Service
Caution
7 In case of a power outage, the not battery-buffered SDRAM content of the MMC is
completely lost. Any individual settings made for the time parameter “error signaling
interval” are also reset to the default value 15 minutes.
When the system is restarted, the automatic recovery action “reload CDB backup”
starts and the customer-individual settings are reloaded. Because this process lasts
longer than 15 minutes, the first error message is always signaled at the end of the
15-minutes default interval. All other errors are then signaled again with the individ-
ually set interval.
Example: The error signaling interval of a HiPath 3550 with activated error signaling
was set to 90 s. After a power outage, the 90 s interval reverts to the default value of
15 minutes. The first error message “no voltage” is signaled 15 minutes after restart-
ing operation of the system. After conclusion of the recovery action “reload CDB
backup”, the original 90 s setting of the error signaling interval is reactivated. All oth-
er errors are signaled after 90 s.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-95
service.fm
Service
Remote Service
P31003-H3560-S100-3-7620, 03/06
12-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Remote Service
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-97
service.fm
Service
Security Features
Security
To ensure that authorized users have access to the HiPath 3000 and to prevent unauthorized
access, users must be identified by a user name and authorized by a password. This applies
to all local and remote administration and maintenance procedures using HiPath 3000 Manag-
er E, Assistant T, HiPath 3000 Manager C, Assistant TC, and AMHOST.
After the first system startup and during country initialization, you can select between the fol-
lowing security options:
● variable password (default)
● fixed password concept
Example of first-time login with Assistant T
Alphanumeric characters can be used with optiset E memory and optiPoint 600 of-
> fice telephones only. Therefore, when changing the user name or password with the
Assistant T/Assistant TC, you may enter additional characters as long as you never
use the optiset E memory and optiPoint 600 office.
P31003-H3560-S100-3-7620, 03/06
12-98 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-99
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
12-100 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
Customer admin.
No User groups
System maint.
accounting
.
(Service)
Develop-
Charge
admin.
(Cust.)
Audit
ment
User
User rights
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-101
service.fm
Service
Security Features
– Manager TC=*95/(Password
No. User groups
– Manager C=office/office
Customer admin. (Cust.)
System maint. (Service)
Name/Password=
Name/Password:
not necessary)
Development
31994/31994
User rights
1. ● Assessing and archiving backup-related log files X X
● Reader rights to system data (error memory, for exam-
ple), not including confidential customer information
2. ● Access rights to all system data (not including develop- X X
ment access rights)
3. ● Access rights to confidential customer information X X X
● Executing customer actions (printing out certain lists,
for example)
4. ● Access rights to non-confidential customer information X X X
5. ● Access rights to parameters and call detail recording X
actions (not including interface parameters for the out-
put device)
6. ● Setting up and reading certain parameters to which no X
other user group has access.
P31003-H3560-S100-3-7620, 03/06
12-102 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
Service tools
● Assistant T and Assistant TC systems
Log on by entering your user name and password (regardless of code lock)
The system can only be accessed using the first two UP0/E connections from the first
SLMO/SLU board in the system.
● HiPath 3000 Manager E and HiPath 3000 Manager C (local)
Log on by entering your user name and password
● HiPath 3000 Manager E (remote), direct connection
Log on by entering your user name and password
The system can be accessed directly using the integrated digital modem (B channel) or the
integrated analog modem. However, the user is required to establish a 5 digit access code
beforehand.
● HiPath 3000 Manager E (remote), callback connection
Log on by entering your user name and password
The system can be accessed using the integrated digital modem (B channel) or the inte-
grated analog modem. However, you have to set up a callback index beforehand.
● HiPath Software Manager
Log on by entering your user name and password
AMHOST
The AMHOST (Administration and Maintenance via HOST) feature allows Plus products to
read certain system information and to change it, if necessary. To enable Plus products to ac-
cess the system, you have to set up a user without a user group in the HiPath 3000 default user
administration. Enter “AMHOST” as the user name and “77777” as the default user password.
You can only change this password if the system is configured using a variable password. In
this case, delete the “AMHOST” user and re-configure the system with the same user name
and a new password.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-103
service.fm
Service
Security Features
When you generate a default customer database offline, a default user table is also
> set up. If you generate a customer database like this, you can only load it into a de-
fault system.
P31003-H3560-S100-3-7620, 03/06
12-104 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
Definition
All accesses to customer-related data in the HiPath 3000 are automatically logged in an area
of the MMC (LOG area) reserved for this purpose. The information recorded includes who the
user is, the data manipulated by the user, and the time. An authorized user (member of the “Re-
vision” user group) can transfer the system data to a PC and assess it.
12.6.2.1 Logging
A log entry contains the following information:
● Date and time
● User name and user group
● Type of activity (format identification) and activity (command entry)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-105
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
12-106 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-107
service.fm
Service
Security Features
Archive
If you request an archive (storage), the system checks whether or not there is already an ar-
chive file (file extension = arc). If it is a file with log data from a previous archive, the file must
match the current customer. In case of a positive result, the system log entries are retrieved
and attached to the existing data in the archive file. At the same time, the data in the system is
deleted.
If malfunctions occur during this procedure (for example, line interruption), the entire procedure
ends and the archive has to be restarted.
If no archive is requested, the revisor can retrieve, view, and print the log entries. However, log
entries remain in the system.
You do not have to log on to the system to use the HiPath 3000 Manager E to check archive
files on the PC monitor. In this case, a password is not required.
Multimedia card
When replacing the multimedia card, the following applies:
● If the memory area for logging data is empty, logging restarts.
● If the memory area for logging data is not empty, logging continues.
P31003-H3560-S100-3-7620, 03/06
12-108 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 12-109
service.fm
Service
Security Features
P31003-H3560-S100-3-7620, 03/06
12-110 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
ip_.fm
IP Fundamentals
Overview
13 IP Fundamentals
13.1 Overview
Chapter contents
This chapter discusses the topics listed in the following table.
Topic
IP Network Requirements, page 13-2
● General Introduction, page 13-2
● H.323 Protocol, page 13-2
● Standards Supported, page 13-3
● QoS - Quality of Service, page 13-4
Network analysis, page 13-6
This section provides introductory information only and does not replace IP training.
>
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 13-1
ip_.fm
IP Fundamentals
IP Network Requirements
For special requirements regarding bandwidth, delay, QoS, etc. for a HiPath 3000/
> 5000 V6.0 customer IP network, please refer to the requirement specifications in the
HiPath 3000/5000 solution contract.
P31003-H3560-S100-3-7620, 03/06
13-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
ip_.fm
IP Fundamentals
IP Network Requirements
“Clear Channel” transmission mode is characterized by the fact that signals are transmitted dig-
itally and the connection is bit-transparent. There is no compression. The transmission rate is
64 Kbps.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 13-3
ip_.fm
IP Fundamentals
IP Network Requirements
Introduction
Data transmission in IP networks can encounter:
● Time problems due to large e-mail attachments and web surfing
● Network bottlenecks as a result of multiple requests for the same web page
● Reduced voice quality due to:
– Delay (decline in voice quality due to delay)
– Variable delays (decline in voice quality due to jitter)
– Packet loss (decline in voice quality due to packet loss)
Quality of Service includes various methods which guarantee certain transmission properties
in packet-orientated networks (IP).
It is thus important, for example, to ensure a minimum bandwidth for Voice over IP for the entire
duration of the transfer operation. When several equal-access applications are operating via IP,
the available transmission link bandwidth (for example, an ISDN B channel, 64K bps) is shared
between these applications. Consequently, packet loss may occur during a voice connection,
causing poor voice quality.
P31003-H3560-S100-3-7620, 03/06
13-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
ip_.fm
IP Fundamentals
IP Network Requirements
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual 13-5
ip_.fm
IP Fundamentals
Network analysis
Network analysis must be performed before installation of the relevant systems and
> applications to guarantee smooth operation in the customer network.
Network analysis determines the conditions under which the customer’s network is
suitable for HiPath 3000/5000. The result report is an integral component of the re-
quirement specifications in the HiPath 3000/5000 solution contract.
The Network Analysis service module is used to check whether the customer’s communication
network is suitable for business-over-IP solutions from Siemens AG (HiPath 3000, HiPath
4000, HiPath 5000, etc.). The assessment is carried out on the basis of parameters preset by
the products. The customer receives a final report in which the network structure and operating
parameters (percentage utilization, delay, jitter) are documented.
Information can be found on the HiPath Network Analysis home page: https://netinfo.icn.sie-
mens.de/es/products/prod_netzwerk_analyse_v2/product/home_page.
Configuration notes
For use when planning Siemens AG Voice-over-IP solutions
For use only in SNMP-based IP data networks (routers, IP switches, hubs)
P31003-H3560-S100-3-7620, 03/06
13-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-1
pcodes.fm
P31003-H3560-S100-3-7620, 03/06
A-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
11 Call detail recording
11 1 CDR/station (call detail recording at station)
11 1 1 View CDR/station; enter station number
11 1 2 Print CDRS
11 2 CDR per trunk (call detail recording per trunk)
11 2 1 View CDR per trunk; select slot/trunk
11 2 2 Print CDRT
11 3 CDR central (call detail recording central)
11 3 1 Output format: 0 = compressed, 1 = long
11 3 2 Station number format, suppress digits: 0 = no, 1 = yes
11 3 3 Incoming calls: 0 = no, 1 = yes
11 3 4 Call duration 0 = no, 1 = yes
11 3 5 Output MSN: 0 = no, 1 = yes
11 3 6 Call charge display: 1 = Amount, 2 = Pulses
11 3 7 Outgoing without connection: 0 = no, 1 = yes
11 4 Call charge factor
Enter 0 % to 10000 %
11 5 ISDN factor
Enter 0 % to 10000 %
11 6 Currency, alphanumeric entry of max. 3 characters (not for U.S.)
11 7 Call log: 0 = no, 1 = yes
11 8 CDRA (call detail recording, attendant), pay phone, station.
11 9 Computing accuracy, decimal digits (0 to 3)
12 Speed dialing system
12 1 Speed dial numbers, external station numbers
000 to 999 (HiPath 3750, HiPath 3550, HiPath 3700, HiPath 3500);
000 to 299 (HiPath 3350, HiPath 3300)
12 2 Speed dial names, alphanumeric entries of up to 16 characters (optiset
E memory and optiPoint 600 office only), only if speed-dialing numbers
have been entered.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-3
pcodes.fm
Code Function
13 Account Code (ACCT)
13 1 Code entries, list 0 to 999
13 2 Checking procedure 0 = Not checked, 1 = Acc. code list, 2 = Number of
digits
13 3 Entry procedure 0 = Optional, 1 = Mandatory
13 4 Code length (1 to 11)
14 Set up station
14 10 Copy station data
14 11 Station type
14 11 0 Standard
14 11 1 Fax
14 11 2 PhoneMail (5 digits)
14 11 3 Loudspeaker
14 11 4 Answer Machine
14 11 5 External MOH
14 11 6 P.O.T MW LED
14 11 7 PhoneMail (6 digits)
14 11 8 Door station with pulsed loop
14 11 9 Memo
14 11 10 Modem
14 12 Station name, alphanumeric entry of up to 16 characters (optiset E mem-
ory and optiPoint 600 office only)
14 13 Override: 0 = denied, 1 = allowed
14 14 Associated Dialing: 0 = denied, 1 = allowed
14 15 DISA: 0 = denied, 1 = allowed
14 16 Call waiting rejection: 0 = off, 1 = on
14 17 Headset 0 = off, 1 = on
14 18 Call pickup group:
HiPath 3750/HiPath 3700: Groups 1 to 32, max. 32 stations
HiPath 3550/HiPath 3500: Groups 1 to 16, max. 32 stations
HiPath 3350/HiPath 3300: Groups 1 to 8, max. 8 stations
14 19 Reset station PIN: 0 = Reset to 00000
P31003-H3560-S100-3-7620, 03/06
A-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
14 20 Override do not disturb 0 = no, 1 = yes
14 21 Missed Calls List: 0 = no, 1 = yes
14 22 MCID: 0 = denied, 1 = allowed
14 23 Call FWD, external: 0 = denied, 1 = allowed
14 25 Data compression 0 = no, 1 = yes
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-5
pcodes.fm
Code Function
14 26 Select language:
11 = German
12 = US English
13 = French
14 = Spanish
15 = English
16 = Italian
17 = Dutch
18 = Portuguese
19 = Finnish
20 = Czech
21 = Danish
22 = Swedish
23 = Norwegian
24 = Turkish
25 = Telekom, German
26 = Polish
27 = Hungarian
28 = Russian
29 = Greek
30 = Slovenian
31 = Serbo-Croatian
32 = Estonian
33 = Latvian
34 = Lithuanian
35 = Chinese
36 = Slovakian
37 = Catalonian
38 = German (2)
39 = English (2)
40 = Romanian
41 = Bulgarian
42 = Macedonian
43 = Serbian (cyr.)
44 = Serbian (lat.)
14 27 Do not Disturb: 0 = off, 1 = on
14 28 Telephone lock intercept: 0 = no, 1 = yes
14 29 Dialing method: 1 = DTMF, 2 = DP
14 30 optiPoint BLF (busy lamp field or BLF), Display: No BLF, one BLF, two
BLFs
P31003-H3560-S100-3-7620, 03/06
A-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
14 31 Ringback protection per station
14 32 Setup station in internal phonebook: 0 = no, 1 = yes
14 33 Edit tel. number 0 = no, 1 = yes
14 34 Monitoring: 0 = not authorized, 1 = authorized
14 35 Keypad dial: 0 = not authorized, 1 = authorized
14 36 Forwarding CFSS
14 37 Speaker calling
14 38 Bar speaker calling
15 CO call privileges
15 1 Direct trunk access day; specify reference station
Enter new data:
0 = No trunk access except by system speed-dialing
1 = Incoming only
2-7 = Allowed list, Allowed list 1-6
8-13 = Denied list, Denied list 1-6
14 = Full access
15 2 Direct trunk access night; specify reference station
Enter new data:
0 = No trunk access except by system speed-dialing
1 = Incoming only
2-7 = Allowed list, Allowed list 1-6
8-13 = Denied list, Denied list 1-6
14 = Full access
15 3 Allowed lists
15 3 1 Allowed list 1, 100 entries
15 3 2 Allowed 2, 10 entries
15 3 3 Allowed 3, 10 entries
15 3 4 Allowed 4, 10 entries
15 3 5 Allowed 5, 10 entries
15 3 6 Allowed 6, 10 entries
15 4 Denied lists
15 4 1 Denied list 1, 50 entries
15 4 2 Denied 2, 10 entries
15 4 3 Denied 3, 10 entries
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-7
pcodes.fm
Code Function
15 4 4 Denied 4, 10 entries
15 4 5 Denied 5, 10 entries
15 4 6 Denied 6, 10 entries
15 5 Number of authorized stations (for verification purposes only)
15 6 Lock Code
0 = No trunk access except by system speed-dialing
1 = Incoming only
2 - 7 = Allowed lists 1-6 (AL 1 to AL 6)
8 - 13 = Denied lists 1-6 (DL 1 to DL 6)
14 = Full access (full)
15 7 Toll restriction, 0 = Digit-by-digit, 1= En-bloc sending
15 8 Switched trunk authorization
15 9 Toll restriction, private
16 Incoming calls
16 10 Internal station numbers
16 10 1 Station
16 10 1 1 Boards
16 10 1 2 Change station number
16 10 1 3 Find station number
16 10 2 Groups
16 11 DID numbers; (internal) station number is displayed; enter (new) station
number
16 12 Intercept position, day; enter new destination, group or Stn. no., max. 6
digits
16 13 Intercept position, night; enter new destination, group or Stn. no., max. 6
digits
16 14 Intercept criteria
16 14 1 on RNA: 0 = no, 1 = yes
16 14 2 on Busy
16 14 2 1 Intercept 0 = no, 1 = yes
16 14 2 2 Call waiting on busy: 0 = no, 1 = yes
16 14 3 on Invalid, intercept: 0 = no, 1 = yes
P31003-H3560-S100-3-7620, 03/06
A-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
16 14 4 on Incomplete, intercept: 0 = no, 1 = yes
16 14 5 on Automatic recall, intercept: 0 = no, 1 = yes
16 15 Hunt/group call
16 15 1 Called station no.; select group and assign destination
16 15 2 Ring type; select group and type:
1 = Circular hunt group
2 = Linear hunt group
3 = Group call
4 = Group call, no answer
5 = Basic MULAP
6 = Executive MULAP
7 = Group call, call waiting
16 15 3 Group name; select group and enter name
(only optiset E memory and optiPoint 600 office)
16 15 4 Select host (master)/executive, group, and station (only stations that are
not the host (master) telephone in another group)
16 16 Call allocation, day; select slot/trunk and assign station no.
16 17 Call allocation, night; select slot/trunk and assign station no.
16 18 Call forwarding—no answer
16 18 1 Select call destination list and destination index (1 – 4).
Call destination lists:
● up to and including V1.2 = 70
● V3.0 or later =
– 500 for HiPath 3750, HiPath 3700
– 376 for HiPath 3550, HiPath 3500
– 70 for all other systems
Select destination (1 – 4), possible entries:
● targeted call number of a station or a group
● * = identical to called station
● #9 = system search of all stations except for the executive exten-
sions
● #201 – #260 = uniform call distribution group 01 to group 60
● #301 – #316 = announcement device 01 to 16
● an external destination, in other words call numbers in satellites and
in the central office
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-9
pcodes.fm
Code Function
16 18 2 Internal calls; select station/group:
● up to and including V1.2 = 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 3 External calls, day; select station/group:
● up to and including V1.2 = 1 – 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 4 External calls, night; select station/group:
● up to and including V1.2 = 1 – 70
● V3.0 or later =
– 1 – 500 for HiPath 3750, HiPath 3700
– 1 – 376 for HiPath 3550, HiPath 3500
– 1 – 70 for all other systems
16 18 5 Number of rings (1 to 15) for station/group
16 18 6 Night bell, location for station/group
16 18 7 Night bell, mode:
1 = Immediate connect, 2 = After timeout
16 18 8 Call forwarding (CF) on busy, 0 = Do not forward call, 1 = Forward call
16 19 Ring cadence: 0 = Ring type 1, 1 = Ring type 2, 2 = Ring type 3
16 20 DTMF DID: 0 = denied, 1 = allowed
16 21 Ringback protection (Brazil): 0 = off, 1 = on
17 Networking
17 11 Simplified dialing: 0 = Off, 1 = On
17 12 Assign trunk group; select slot/trunk and assign trunk group
Route 1-8 (HiPath 3350, HiPath 3300)
Route 1-16 (HiPath 3750, HiPath 3550, HiPath 3700, HiPath 3500)
17 13 Overflow route; select route and assign overflow route
17 14 Trunk type CO/CS; select trunk type: 0 = CO, 1 = CS
17 15 Route name; select route and enter name (optiset E memory and opti-
Point 600 office only)
17 16 Route seizure; Route selection: 0=cyclic, 1= linear
P31003-H3560-S100-3-7620, 03/06
A-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
17 17 Rerouting (optimized B channel utilization)
17 17 1 Route optimize active: 0 = No, 1 = If route is known, 2 = Always
17 17 2 Change route: 0 = denied, 1 = allowed
17 18 Central intercept
17 19 Call data routing
17 19 1 Destination system
17 20 Digit repetition; select trunk group: 0 = off, 1 = on
17 21 Path optimization: 0 = no, 1 = yes
17 22 QSig: Voice mail
17 22 1 Callback access number
17 22 2 Callback access name
17 23 QSig: Busy signaling
17 23 1 Stations: 0 = no, 1 = yes
17 23 2 Station number, destination system
17 23 3 System number, destination system
17 24 Station number type: 1 = Internal, 2 = DID, 3 = Internal/DID
18 Traffic restriction
18 1 Configure exec./sec. groups; select group, enter:
1 = Exec. 1, 2 = Exec. 2, 3 = Sec. 1, 4 = Sec. 2
HiPath 3750/HiPath 3700: Group 1-16
HiPath 3550/HiPath 3500: Group 1-10
HiPath 3350/HiPath 3300: Group 1-4
18 2 Hotline
18 2 1 Hotline destinations
HiPath 3750, HiPath 3550, HiPath 3700, HiPath 3500: Destination 1-6
HiPath 3350/HiPath 3300: Destination 1
18 2 2 Hotline station number
18 2 2 1 Hotline Mode: 0 = Off, 1 = Hotline, 2 = Off-hook alarm after timeout
18 2 2 2 Hotline assignment
HiPath 3750/HiPath 3550/HiPath 3700/HiPath 3500 1-6
HiPath 3350/HiPath 3300 1
18 2 3 Hotline timeout, 1-99 x s
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-11
pcodes.fm
Code Function
18 3 ITR groups (internal traffic restriction groups)
18 3 1 Group assignment
18 3 1 1 Station (Group 1-6)
18 3 1 2 Trunks; select slot and trunk (Group 1-6)
18 3 1 3 Speed-dialing number assignment
18 3 1 3 - 1 Minimum speed-dialing group, Select group, 0 to 999
18 3 1 3 - 2 Maximum speed-dialing group, Select group, 0 to 999
18 3 2 Connection groups
18 3 2 1 Matrix, Select Group: 0 = no, 1 = yes
19 Displays
19 11 Text messages: select message no. 0 to 9 and enter alphanumeric text
(up to 24 characters) (optiset E memory and optiPoint 600 office only)
19 12 Advisory messages: select message no. 0 to 9 and enter alphanumeric
text (up to 24 characters) (optiset E memory and optiPoint 600 office
only)
19 13 Enter 4-digit time in the format HHMM (hour minute)
19 14 Enter 6-digit date in the format DDMMYY (day month year)
19 15 Call duration: 0 = off, 1 = on
19 16 Name, Call numbers: 0 = Calling ID only, 1 = Name, 2 = Name and calling
ID
19 17 Automatic recall 1 = Caller, 2 = Transferred destination
19 18 Transfer before answer: 1 = Transferred by, 2 = Transferred to
20 ISDN parameters
20 1 Call number suppression 0 = off, 1 = on
20 2 System station number - incoming
20 2 1 Station number; select trunk group
20 2 2 National number; select trunk group
20 2 3 International number; select trunk group
20 2 4 Type, outgoing; select trunk group:
0 = Unknown, 1 = Station, 2 = National, 3 = International, 4 = Internal
20 2 5 National prefix (U.S. = 1)
20 2 6 International prefix (U.S. = 011)
P31003-H3560-S100-3-7620, 03/06
A-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
20 3 Reference clock
20 3 1 Allowed nos. list; select position (slot and port)
20 3 2 Denied nos. list; select position (slot and port)
20 4 EU parameters (not for U.S.)
20 4 1 S0 port configuration; select slot/port and determine connection type (not
for U.S.):
1 = Automatic
2 = Euro CO PP
3 = Euro CO PMP
4 = Euro bus
5 = CorNet 1
6 = CorNet 2
7 = ECMA-QSIG
8 = ISO-QSIG
20 4 2 S2M port configuration; select slot/port and determine connection type
(not for U.S.):
1 = Euro CO PP
2 = CorNet 1
3 = CorNet 2
4 = ECMA-QSIG
5 = ISO-QSIG
20 4 3 S0 bus MSN (for verification purposes only)
20 4 4 Call forwarding PMP
20 4 4 1 Multiple subscriber numbers, select index, 1 to 10
20 4 4 2 MSN trunks, select index, 1 to 10
20 5 US parameters (for U.S. only)
20 5 1 BRI parameter
20 5 1 1 CO/protocol:
1 = AT&T/NI 1
2 = AT&T/Custom
3 = Siemens/NI 1
4 = NT/NI 1
20 5 1 2 SPID admin, select station, select slot/port
20 5 1 3 CAID admin, stn., select CAID
20 5 1 4 PDID admin, stn., select PDID
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-13
pcodes.fm
Code Function
20 5 1 5 FIN - for message waiting
20 5 1 6 CACH EKTS, select slot/port: 0 = off, 1 = on
20 5 2 PRI parameters
20 5 2 11 Protocol type:
11 = AT&T/Custom
12 = AT&T/NI2
13 = AT&T/NI2 OSA
14 = AT&T/4ESS
15 = Siemens/Custom
16 = Siemens/Custom OSA
17 = Siemens/NI2
18 = Siemens/NI2 OSA
19 = MCI/DEX600
20 = MCI/DMS250
21 = BELL/DMS100
22 = BELL DMS100 TNS
23 = Nortel/DMS100
24 = Nortel DMS100 TNS
25 = SPRINT/DMS250
26 = Westinghouse
27 = FTS/DMS250
28 = FTS/5ESS
29 = GENERIC/NI2
30 = GENERIC/NI2 OSA
31 = QSIG
32 = IDA-P
20 5 2 12 Frame/line/encod, select slot
0 = ESF/B8ZS/Normal
1 = SF/ZCS/Inverted
20 5 2 13 Inwats parameter
20 5 2 13 - Route
1
20 5 2 13 - DNIS
2
20 5 2 13 - Entrance telephone ring destination
3
P31003-H3560-S100-3-7620, 03/06
A-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
20 5 2 14 Calling service, select trunk group
11 = NONE
12 = AT&TSDN-GSDN
13 = AT&TSDDN
14 = MCI-VN-VS
15 = SPRINT-VPN
16 = WICN-PV
17 = MEG800-TFM
18 = MCI 800
19 = ULTRA-800
20 = WICN-INWATS
21 = MEG
22 = MCI-PRISIM-WATS
23 = SPR-ULTRA-WATS
24 = WICN-OUTWATS
25 = ACCU-SDS
26 = LDS-WC-TSAA
27 = INTER-800
28 = MULTIQUEST
29 = MCI-900
30 = SDS56
31 = SDS64C
32 = SDS64R
33 = DMS100-PV
34 = DMS100-INWATS
35 = DMS100-OUTWATS
36 = DMS100-FX
37 = 5ESS-INWATS
38 = WATS-MSB
39 = DMS100-TIE
40 = NI2-INWATS
41 = NI2-OUTWATS
42 = NI2-FX
43 = NI2-TIE
44 = NI2-HOTEL
45 = NI2-SCOCS
46 = CALL-BY-CALL 1
47 = CALL-BY-CALL 2
48 = CALL-BY-CALL 3
49 = CALL-BY-CALL 4
50 = WATS-BANDED
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-15
pcodes.fm
Code Function
20 5 2 15 CBC pool:
11 = AT&TSDN-GSDN
12 = AT&TSDDN
13 = MCI-VN-VS
14 = SPRINT-VPN
15 = WICN-PV
16 = MEG800-TFM
17 = MCI 800
18 = ULTRA-800
19 = WICN-INWATS
20 = MEG
21 = MCI-PRISIM-WATS
22 = SPR-ULTRA-WATS
23 = WICN-OUTWATS
24 = ACCU-SDS
25 = LDS-WC-TSAA
26 = INTER-800
27 = MULTIQUEST
28 = MCI-900
29 = SDS56
30 = SDS64C
31 = SDS64R
32 = DMS100-PV
33 = DMS100-INWATS
34 = DMS100-OUTWATS
35 = DMS100-FX
36 = 5ESS-INWATS
37 = WATS-MSB
38 = DMS100-TIE
39 = NI2-INWATS
40 = NI2-OUTWATS
41 = NI2-FX
42 = NI2-TIE
43 = NI2-HOTEL
44 = NI2-SCOCS
20 5 2 16 CBC access code
20 5 3 S0 bus MSN, select slot/port
20 5 4 QSig: S0 parameter
20 6 QSIG parameter
P31003-H3560-S100-3-7620, 03/06
A-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
20 6 1 System number
20 6 2 Group number
20 7 Keypad dial: 0 = denied, 1 = allowed
20 8 System station number - outgoing
20 8 1 Port number
20 8 2 National number
20 8 3 International number
20 8 4 Suppress station number
21 Analog CO interface
21 1 Dialing method; select slot/trunk:
0 = Automatic,
1 = DTMF,
2 = Dial pulses
3 = MFC-R2,
4 = MFC-R2 with OAD
21 2 Delayed dialing; select trunk group:
0 = No pause, 1 = 1 s, 2 = 3 s, 3 = 6 s, 4 = 9 s
21 3 Trunk call pause; select trunk group: 1 = 6 s, 2 = 13 s
21 4 Line Length; select slot and trunk: 0 = Short 1 = Long
21 5 Charge data module, select slot/trunk: 0 = off, 1 = on
21 6 Silent reversal: 0 = no, 1 = yes
21 7 Port status: 0 = on, 1 = Off (SW), 2 = Off (HW), 3 = Off (HW, SW)
21 8 Allocated without extension
22 System settings
22 11 Music on Hold (MOH): 0= Off, 1 = No ring tone, 2 = Ring tone, 3 = An-
nouncement device 1
22 12 Internal Phonebook: 0 = No, 1 = Internal, 2 = LDAP, 3 = All
22 13 V.24 (RS-232) configuration
22 13 1 Select CB baud rate: 1 = 9600 baud, 2 = 2400 baud, 3 = 19200 baud
22 13 2 Port assignment
22 13 2 1 CSTA/CDRC (call detail recording central), output: 0 = none, 1 = V.24
port, 2 = UPN port, 3 = PC-VPL, 4 = LAN
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-17
pcodes.fm
Code Function
22 13 2 2 Port for CDRS (call detail recording at station), output: 0 = none, 1 = V.24
port, 2 = UPN port
22 13 2 3 Port for CDRT (call detail recording per trunk), output: 0 = none, 1 = V.24
port, 2 = UPN port
22 13 2 4 Port for CDB printout
22 13 2 5 Port for CDR printout
22 13 2 6 Port for CDRA (call detail recording, attendant); if a pay phone is config-
ured, also see code 11 8), output: 0 = none, 1 = V.24 port, 2 = UPN port
22 14 Call FWD, external
22 14 1 Connect call: 0 = On answer, 1 = Immediately.
22 14 2 Call forwarding: 0 = deactivate, 1 = activate
22 15 Caller list mode: 1 = Only external, 2 = External and Internal, 3 = External
ring/call
22 16 Applications
22 16 1 Call distribution: 0 = no, 1 = yes
22 17 Tones
22 17 1 Conference, Warning tone: 0 = off, 1 = on
22 17 2 Call pickup, Warning tone: 0 = off, 1 = on
22 18 Transfer key (Retrieve): 1 = Press once, 2 = Press twice
22 19 Class of service
22 19 1 Night answer, Pos. 1-5; enter station
22 19 2 Central telephone lock
22 20 DTMF automatic: 0= no, 1 = yes
22 21 Key click: 0=Off, 1= Volume 1 ... 4 = Volume 4
22 22 DTMF - Pulse/Pause: 1 = 70/70 msec, 2 = 80/80 msec, 3 = 80/250 msec,
4 = 200/200 msec
22 23 Phone lock destination
22 24 Stn. relocate: 0 = denied, 1 = allowed
22 25 Trunk reservation: 0 = off, 1 = on
22 26 Speaking volume: 0 = default, 1 = high
22 27 CO features (Transfer/Conference/Drop): 0 = disabled, 1 = enabled
22 28 Feature Identification Number (FIN) for Transfer (U.S. only)
P31003-H3560-S100-3-7620, 03/06
A-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
22 29 Feature Identification Number (FIN) for Conference (U.S. only)
22 30 Feature Identification Number (FIN) for Drop (U.S. only)
22 31 MSN default: 0 = off, 1 = on
22 32 DTMF hidden: 0 = off, 1 = on
22 33 Announcement with connection: 0 = denied, 1 = allowed
22 34 MFC-R2 parameters
22 34 1 Ringback protection
22 34 2 DID digits
22 35 Common hold
22 35 1 By hanging up
22 35 2 Without hanging up
22 36 Switch line, DSS: 0 = no, 1 = yes
(Status 1 = U.S., Status 0 = Rest of World (ROW)
22 37 Advisory call 0 = off, 1 = on
22 38 Trace stop facility
22 38 1 Stop trace
22 38 1 01 Assistant: 0 = inactive, 1 = active
22 38 1 09 HW: 0 = inactive, 1 = active
22 38 1 12 Processor: 0 = inactive, 1 = active
22 38 1 15 APSXF: 0 = inactive, 1 = active
22 38 1 16 General: 0 = inactive, 1 = active
(error 19 cannot be set to inactive)
22 38 1 20 CP: 0 = inactive, 1 = active
22 38 1 21 DH: 0 = inactive, 1 = active
22 38 1 23 Network: 0 = inactive, 1 = active
22 38 1 26 Presence 0 = inactive, 1 = active
22 38 1 28 Recovery: 0 = inactive, 1 = active
22 38 1 29 IO Process: 0 = inactive, 1 = active
22 38 1 30 LW: 0 = inactive, 1 = active (0 to n)
22 38 1 11 LW date: 0 = inactive, 1 = active (41 to n)
22 38 2 Reset: 1 = Delete all/2 = System default
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-19
pcodes.fm
Code Function
22 39 IP access
22 39 1 IP interface, mode:
0 = inactive
1 = HIP Forwarding
2 = LIM
3 = SLIP Routing
22 39 2 IP address, data (7 ... 15): x.x.x.x (x = 0 ... 255)
Use either “*” or “.” as a separator.
22 39 3 Subnet mask
22 39 4 Gateway IP address
22 40 Open numbering scheme
22 40 1 Active/inactive
22 40 2 Voice mail node number
22 40 3 Node number
22 41 UCD permanently available: 0 = inactive, 1 = active
23 Code
23 1 Substitute code *, code 75
23 2 Substitute code #, code 76
23 3 Trunk access code; select slot and trunk and enter new code
23 4 Route code; Select route followed by position 1-10 for code and enter
new code
Route 1-8 (HiPath 3350HiPath 3300,)
Route 1-16 (HiPath 3750, HiPath 3550, HiPath 3700, HiPath 3500)
23 5 Attendant code
23 5 1 Attendant code DID
23 5 2 Attendant code internal
23 6 Second trunk access code
23 7 Reset telephone lock code
23 8 Hotel terminal
24 Door relay
24 1 Entrance phone; select door, max. 6 digits, door 1-4
24 2 Destination; select door, max. 6 digits, door 1-4
P31003-H3560-S100-3-7620, 03/06
A-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
24 3 Door opener, select door: 0 = not available, 1 = available, 2 = available
with DTMF, doors 1-4
24 4 Call forwarding, door, external; select door: 0 = deactivate, 1 = activate
24 5 Door opener, DTMF, select station: 0 = denied, 1 = allowed
25 Announcement/Music
25 1 Announcement devices
25 1 1 In system (select announcement device 1 ... 16)
25 1 2 Via server (select announcement device 1 ... 16)
25 2 Type of ann., select ann. device: 1 = Ann. type, 2 = Music on hold, 3 =
Internal music
25 3 Announcement prior to answer; select slot and trunk
25 4 External MOH
(Only enter analog line module stations.)
26 Relays
26 1 Type; select relay 1 to 4 and assign function:
11 = Manual on and off
12 = Off after timeout
13 = Door opener
14 = Speaker amplifier (starting contact for amplifier)
15 = Busy display
16 = Music on hold
17 = Call charge pulse
18 = Second bell
19 = Station active
20 = Announcement
26 2 Switching time
Select relay 1 through 4 and enter up to 3 digits (0 to 255)
26 3 Assigned station
Select relay 1 through 4 and enter stations or groups
(up to 5 digits)
26 4 Relay name; select relay 1 through 4, enter alphanumeric name of max.
16 characters (optiset E memory and optiPoint 600 office only)
27 Sensors (HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300 only)
27 1 Type: 0 = Alarm, 1 = Call distribution
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-21
pcodes.fm
Code Function
27 2 Destination station no.; select sensor 1 - 4
External station with seizure code (trunk/direction)
Internal station with station prefix (if programmed)
27 3 Station no. for announ.; select sensor 1 - 4 and enter station or group
number (max. 6 digits)
27 4 Infobox control data; select sensor 1 - 4 and enter control characters 0 -
9, *, #, max. 24 digits
27 5 Call duration; select sensor 1 through 4 and enter 1 to 255
27 6 Call pause; select sensor 1 through 4 and enter 0 to 255
27 7 Number of rings; select sensor 1 through 4 and enter 1 to 255
27 8 Block time; select sensor 1 through 4 and enter 0 to 255
27 9 Sensor text; select sensor 1 to 4, enter alphanumeric text of up 16 char-
acters (optiset E memory and optiPoint 600 office only)
28 Edit CDB
28 1 Print CDB data
28 2 Save CDB data
28 2 1 CDB to MMC
28 2 2 CDB from MMC
29 System details
29 1 System
29 1 1 System type (for verification purposes only)
29 1 2 SWversion (for verification purposes only)
29 2 Status Display
29 2 1 Call forwarding, external, 0 = Off, 1 = On (for verification purposes only)
29 2 2 Night service, 0 = Off, 1 = On (for verification purposes only)
29 2 3 Trunk, 0 = Inactive, 1 = Active (for verification purposes only)
29 2 4 Ping, 1 = IP address, 2 = Start
29 2 5 MAC address
29 3 Options (HiPath 3550, HiPath 3350, HiPath 3500 and HiPath 3300 only)
P31003-H3560-S100-3-7620, 03/06
A-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
29 3 1 Type per option (for review only)
1 = Relays
2 = Call detail recording
3 = Fax/DID
4 = ANI
5 = Announcement (Beyer)
29 3 2 Software version for each option (1 to 16) (for verification purposes only)
29 3 3 Reset options
29 4 Boards
29 4 1 Board type, select slot:
11 = TMS2
12 = TMST1 - digital
13 = TIEL
14 = TMDID
15 = TML8W
16 = TMOM
17 = TMGL8
18 = TLA2
19 = TLA4
20 = TLA8
21 = TS2
22 = TMGL2
23 = TMGL4
24 = TMQ2
25 = TMQ4
26 = TST1 - digital
27 = STMD
28 = STLS2
29 = STLS4
30 = SLA16
31 = SLMO8
32 = SLMO24
33 = SLMC8 (CMI V1)
34 = 4SLA
35 = 8SLA
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-23
pcodes.fm
Code Function
29 4 1 Board type, select slot:
36 = 16SLA
37 = SLU8
38 = ILAN
39 = SLC16 (CMI V2.2M)
42 = SLMO8K
43 = SLMO24K
44 = SLA8N
45 = SLA16N
46 = SLA24N
47 = TMAMF
48 = CR8
49 = SLU4 (Octopus E 10)
50 = SLU2 (Octopus E 10)
51 = HXGM (HiPath 3750, HiPath 3700)
52 = HXGS (HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300)
53 = IVMS8
54 = IVML8
55 = IVML24
56 = SLAS16
57 = TMCAS
58 = SLUC8 (UP0/E interfaces on CBCC, CBRC, CBCP)
59 = SLUC4 (UP0/E interfaces on SBSCO)
60 = SLUC2 (UP0/E interfaces on SBSCS)
61 = SLAS4N
62 = SLAS8N
63 = IVMP8
64 = HXGM3
65 = HXGS3
66 = SLC16N
67 = STMD2
68 = STLS2N
69 = STLS4N
70 = SLMO2
P31003-H3560-S100-3-7620, 03/06
A-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
29 4 1 Board type, select slot:
71 = TMEW2
72 = DIUN2
73 = SLMA8
74 = SLMA3
75 = SLMA2
76 = SLMO8_HP4K
77 = STMD3
78 = SLCN
79 = STMI2
80 = IVMN8
81 = IVMNL
82 = TM2LP
83 = TMDID_HP4K
84 = TMC16
85 = DIU2U
86 = EVM2
87 = TS2
88 = STMD3 (feeding)
29 4 2 xx Reset board (for board no., see 29-4-1)
29 4 3 0 - 9 Board status
29 4 4 Lock/release card
29 5 Country initialization
29 5 1 Variable password
29 5 1 00 See Select country code
to
99
29 5 2 Fixed password
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-25
pcodes.fm
Code Function
29 5 2 00 Select country code
to 11 = Germany
99 12 = Netherlands
13 = France
14 = Finland
15 = United Kingdom
16 = Italy
17 = Spain
18 = Portugal
19 = Switzerland
20 = Austria
21 = International
22 = Ireland
23 = Belgium
24 = Brazil
25 = South Africa
26 = China
28 = India
29 = Czech Republic
30 = Denmark
31 = Australia
32 = Argentina
33 = Philippines
35 = Brazil 2
36 = Singapore
37 = Hungary
38 = Malaysia
40 = Indonesia
41 = Russia
42 = Thailand
46 = Poland
47 = Greece
49 = Sweden
50 = Norway
51 = Turkey
52 = U.S.
53 = Pakistan
54 = Hong Kong
55 = New Zealand
56 = Taiwan
57 = Korea
P31003-H3560-S100-3-7620, 03/06
A-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
29 6 Virtual subscribers
29 6 1 Configure stations
29 6 2 Display stations
30 Remote service
30 1 DTMF access: 0 = No access, 1 = Access as host (primary), 2 = Access
as client (secondary), 3 = Host and client (primary and secondary)
30 2 ISDN trunk access: 0 = Enable procedure, 1 = Logon (DID) without PIN,
2 = Logon (DID) with PIN, 3 = Callback
30 3 Other access: 0 = Enable procedure, 1 = Logon without code, 2 = Logon
(DID) with code, 3 = Callback
30 4 Reset password
30 5 Integrated modem
30 5 1 Station number, remote service, max. 6 digits
30 5 2 DID number, remote service
30 5 3 CAID admin (for U.S. only)
30 6 Digital modem
30 6 1 Station number, remote service, max. 6 digits
30 6 2 DID number, remote service
30 6 3 CAID admin (for U.S. only)
30 7 Callback connection
30 7 1 Destination; select position (1-6)
30 7 2 Password; select position (1-6)
30 7 3 X.75 protocol: 0 = no, 1 = yes
30 8 Automatic customer database printout: 0 = no, 1 = yes
30 9 USBS D channel access
30 9 1 Station number, remote service
30 9 2 DID number, remote service
31 Call distribution
31 1 Group assignment; select group ID
31 2 Group parameters
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-27
pcodes.fm
Code Function
31 2 1 Announcement device; select group
HiPath 3750/HiPath 3700: Announcement device 1-16
HiPath 3550/HiPath 3350/HiPath 3500/HiPath 3300: Announcement de-
vice 1-4
31 2 2 Wait times; select group, time: 1-9 x 30s
31 2 3 Call cycles
31 2 3 1 Primary cycles; select group
31 2 3 2 Secondary cycles; select group
31 2 4 AICC connection; select group 0 = off, 1 = on
31 2 5 Max. waiting calls; select group
31 3 Wrap-up time 0 = no wrap-up time, 1-20 = wrap-up x 30s
31 4 Call priority external; select slot/trunk
31 5 Call priority internal
32 Paging
32 1 PSE port (slot and trunk)
32 2 Radio paging type (only HiPath 3750/HiPath 3700): 1 = standard, 2 = en-
hanced
32 3 Protocol: 1 = ESPA 4.4.5, 2 = ESPA 4.4.3
32 4 Operating mode
32 4 1 Mode urgent
32 4 2 Mode normal
32 4 3 Mode text
32 5 Display
32 5 1 Call number
32 5 1 1 Number of digits
32 5 1 2 Display, filler: 0=none, 1=left, 2=right
32 5 1 3 Filler
32 5 2 Text
32 5 2 1 Number of digits
32 5 2 2 Display, filler: 0=none, 1=left, 2=right
32 5 2 3 Filler
P31003-H3560-S100-3-7620, 03/06
A-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
32 6 PSE data transfer; select sequence: 1 = Operating mode, 2 = Call no., 3
= Text
32 7 PSE dial assignment; select station (not for U.S.)
32 8 PSE dial numbers; select index
33 Attendant
33 1 Queued calls
33 3 Speed extending: 0 = denied, 1 = allowed
33 4 Extend undialed lines: 0 = denied, 1 = allowed
34 DISA
34 1 Day/night. select slot / line: 0 = None, 1 = Only night, 2 = Only day, 3 =
Day and night
34 2 DID number
34 3 Security mode: 0 = After timeout, 1 = After #
34 4 CAID admin (for U.S. only)
35 Least cost routing (LCR) (optiset E memory and optiPoint 600 office
only)
35 1 LCR on or off: 0 = off, 1 = on
35 2 Digit transmission: 0 = Digit-by-digit, 1= En-bloc sending
35 3 Dial rule
35 3 1 Name; select line
35 3 2 Format; select line
35 3 3 Type; select line: 0 = undefined, 1 = main network supplier, 2 = 1-level,
3 = 2-level, 4 = CN, 5 = DICS, 6 = PRI
35 4 Authorization code; select index (1-16)
35 5 LCR - schedule
35 5 1 Time limit; select day index (1 = Monday to 7 = Sunday) and time format
(hhmm)
35 5 2 Timezone; select day index (1 = Monday to 7 = Sunday) and time period
1-8
35 6 Class of service (1 to 15); select station
35 7 Route tables
35 7 1 Route; select table/line
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-29
pcodes.fm
Code Function
35 7 2 Assign dial rule; select table/line
35 7 3 Min. authorization; select table/line
35 7 4 Assign timezone; select table/line
35 7 5 Warning, Select table/line: 1 = None, 2 = Display, 3 = Tone, 4 = Display
and Tone
35 8 Dial plan
35 8 1 Dialed digits; select line
35 8 2 Assign route table; select line
35 8 3 Account Codes: 0 = no, 1 = yes
35 8 4 CO call privileges, personal calls: 0 = no, 1 = yes
35 8 5 Toll restriction: 0 = no, 1 = yes
35 8 6 Emergency
36 HiPath Cordless Office
36 1 Log on CMI unit; select device: 1 = inactive
36 2 CMI code; select device
36 3 CMI number; select device, changes not possible
36 4 Reset cordless code
36 5 DECT identification, data:
1. E/ARC
2. EIC
3. FPN
4. FPS
37 Security
37 1 Change password
P31003-H3560-S100-3-7620, 03/06
A-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
pcodes.fm
System Programming Codes (Expert Mode Codes)
Code Function
51 – 63 Customer administration (previously Assistant TC)
51 Speed dialing system
51 1 Speed-dialing numbers
51 2 Speed-dialing names
52 Time, hour/minute
53 Date, ddmmyy
54 Call detail recording
(does not appear if another station has call detail recording authoriza-
tion)
54 1 CDR at station
54 1 1 Edit CDRS
54 1 2 Print CDRS
54 2 CDR per trunk
54 2 1 Edit CDRT
54 2 2 Print CDRT
54 4 Call charge factor
54 5 ISDN factor
54 6 Currency designation
54 7 Call log
54 8 CDRA pay phone
55 Station name
56 Text messages
57 Advisory messages
58 Select language
59 Group names
60 Account codes
60 1 Account code list
60 2 Checking procedure, 0 = Not checked, 1 = ACCT list, 2 = Number of dig-
its
60 3 Entry procedure, 0 = Optional, 1 = Mandatory
60 4 Number of digits
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual A-31
pcodes.fm
Code Function
61 Hotline
61 1 Hotline destinations
61 2 Hotline station
61 2 1 Hotline mode, 0 = Off, 1 = Hotline, 2 = Code blue
61 2 2 Hotline assignment
61 3 Hotline timeout
62 Codes, remote service
63 Codes, Cordless
64 Security
64 1 Change password
99 Access
The “bolded” messages appear in optiset E memory and optiPoint 600 office telephones only.
P31003-H3560-S100-3-7620, 03/06
A-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Table B-1 contains all the activation/deactivation procedures for analog workpoint clients,
TDM workpoint clients without a display and CMI mobile phones. The table only
contains the access codes for TDM workpoint clients with a display, CMI feature
mobile phones and IP workpoint clients. The procedures for S0 workpoint clients
either correspond to procedures for analog workpoint clients or are handled via
the relevant ISDN protocol with the terminal-specific user interface.
The table also contains information about the effect of the telephone lock and
the status-specific locking of features.
Table B-1 contains a description of the various types of workpoint clients.
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Activate relay *90+Relay no. 7590... *90... – V, T – H – AN, DIG, ENT, X RK,
S0, CMI, IPSC BS
Deactivate re- #90+Relay no. 7690... #90... – V, T – H – AN, DIG, ENT, X RK,
lay S0, CMI, IPSC BS
Accept call *55 7555 *55 – V BR, U Mouse AN, DIG, ENT, – – Also possible via
waiting (camp- WA, click, S0, CMI, the DSS, GESP,
on) RG, Drag& IPSC, IPH3 LTG or MUSAP key
GS, Drop
BS
Bar call wait- #490 76490 #490 – V, T RH U1 Fea- AN, DIG, ENT, X RK,
ing (automatic) ture key S0, CMI, IPSC BS
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-1
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Allow call wait- *490 75490 *490 – V, T RH U1 Fea- AN, DIG, ENT, X RK,
ing (automatic) ture key S0, CMI, IPSC BS
Silent call wait- *87 7587 *87 – V, T RH U1 Local AN, DIG, ENT, X RK,
ing (camp-on) feature S0, CMI, IPSC BS
on
Silent call wait- #87 7687 #87 – V, T RH U1 Local AN, DIG, ENT, X RK,
ing (camp-on) feature S0, CMI, IPSC BS
off
Logon mode *942+Code – *942 – – – H – DIG, CMI X
(for handset) +Stn. no.
Query caller – – #82... – V RH, U Local DIG, IPSC, X Only if enabled
list BR feature IPSI
menu
Missed calls - – – *82 – – RG, – Local DIG, IPSC X RK, Only if enabled
save number/ GS active BR,
save call num- menu WA
ber
Do not disturb *97 7597 *97 – V, T RH U Fea- AN, DIG, ENT, X RK,
on ture key S0, CMI, IPSC BS
Do not disturb #97 7697 #97 – V, T RH U Fea- AN, DIG, ENT, X RK,
off ture key S0, CMI, IPSC BS
Call forward- *1+Type+Stn. 751... *1... – V, U, RH U Fea- AN, DIG, ENT, X RK, Later selection of
ing on, internal no. or T ture key S0, CMI, IPSC BS the forwarding type:
or external Call for- 1 = All calls, 2 = Ex.
warding calls only, 3 = nt.
(local S0 calls only
WpC
function-
ality)
Call forward- #1 761 #1 – V, T RH U1 Fea- AN, DIG, ENT, X RK,
ing off ture key S0, CMI, IPSC BS
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
B-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Call forward- – – *64... – V, U, RH U1 – AN, DIG, ENT, X RK, Only for S0 trunk
ing in EDSS1 T S0, CMI, IPSC BS connection and au-
trunk on (not thorized stations.
for tenant ser- Later selection of
vice) the forwarding type:
1 = immediate, 2 =
Call forward- – – #64... – V, T RH U1 – AN, DIG, ENT, X
unanswered calls,
ing in EDSS1 S0, CMI, IPSC
3 = on busy.
trunk off (not
All call forwarding
for tenant ser-
types can be acti-
vice)
vated independent-
ly of each other.
CFSS (Call – – *9411 – V, U, – U1 – IPSC X RK, CFSS (call forward-
forwarding sta- T BS ing station out of
tion out of ser- service) has higher
vice) priority than normal
call forwarding.
CFSS (Call – – #9411 – V, T – U1 – IPSC X
forwarding sta-
tion out of ser-
vice)
Call forward- *501+MU- 75501 *501 – V, T – H – AN, DIG, ENT, Only for MULAP
ing on for each LAP+Type+Stn. S0, CMI, IPSC members
MULAP no.
Call forward- #501+MULAP 76501 #501 V, T – H – AN, DIG, ENT, Only for MULAP
ing off for each S0, CMI, IPSC members
MULAP
UCD (uniform *401+ID – *401.. – V, U, – U2 Fea- AN, DIG, ENT, X RK, Only for UCD group
call distribu- T ture key CMI, IPSC BS members
tion), logon
UCD (uniform #401 – #401 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
call distribu- CMI, IPSC BS stations
tion), logoff
UCD, available *402 – *402 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
CMI, IPSC BS stations
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-3
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
UCD, unavail- #402 – #402 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
able CMI, IPSC BS stations
UCD, rework *403 – *403 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
on CMI, IPSC BS stations
Call distribu- #403 – #403 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
tion, rework off CMI, IPSC BS stations
Call distribu- *404 +* or Stn. – *404 ... – V, U, – U2 – AN, DIG, ENT, X RK, Only for logged on
tion, night des- no. T CMI, IPSC BS stations
tination on
Call distribu- #404 – #404 – V, T – U2 – AN, DIG, ENT, X RK, Only for logged on
tion, night des- CMI, IPSC BS stations
tination off
Call distribu- – – *405 – V – U2 – AN, DIG, ENT, X RK, Only for logged on
tion, queue CMI, IPSC BS stations
Call accep- – – – – V – – Mouse AN, DIG, ENT, X RH, Can only be activat-
tance click, CMI, IPSC BR, ed using key
Drag& WA,
Drop BS,
RG
Advisory mes- – – *69... – V, U, RH U1 Local DIG, CMI, X RK,
sage on T feature IPSC BS
menu
Advisory mes- – – #69... – V, T RH U1 Local DIG, CMI, X RK,
sage off feature IPSC BS
menu
Associated di- *67+Stn.+Stn. 7567... *67... – U – H – AN, DIG, ENT, X Only for authorized
aling no. S0, CMI, IPSC stations
Associated *83+Stn.+ 7583 *83... – U – H – AN, DIG, ENT, X RK, Only for authorized
services Services proce- S0, CMI, IPSC BS stations
dure...
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
B-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-5
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Speaker calls *80+Stn. no. 7580 *80 – V, U – H Menu AN, DIG, ENT, – RK, Speaker calls to a
S0, CMI, IPSC BS. group: Paging only
WA, possible if “Speaker
RG call” has been en-
abled for the called
party. The called
party’s microphone
is activated if “Di-
rect Answering” has
been enabled for
this party (not for
paging).
Hands free an- – – *96 – V, T RH U1 – DIG, CMI, X – Only for WpC with
swerback on IPSC speakerphone
Hands free an- – – #96 – V, T RH U1 – DIG, CMI, X – Only for WpC with
swerback off IPSC speakerphone
DISA (Direct – – – – – – – – – – – Activation only pos-
Inward System sible from external
Access) location for autho-
rized stations/lines.
HiPath 5000 does
not support the
DISA feature.
DISA internal *47+DISA stn. – *47... – V, U RH U1 – DIG, ENT, AN, X WA, Within a HiPath
no.+DISA IP RG, 5000 network only.
STN.+service RK, Features cannot be
+Suffix dialing BS activated from ana-
log (DP) or S0
WpC.
Discreet call- *945+Stn. no. *945.. – U – – – AN, DIG, S0, X WA, Only for authorized
ing on IPSC RG, stations
BS,
RK,
GS
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
B-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Discreet call- #945+Stn. no. *945.. – U – – – AN, DIG, S0, X WA, Only for authorized
ing off IPSC RG, stations
BS,
RK,
GS
Relocate: *9419 – *9419 – – – – Possi- DIG, ENT X WA,
Save configu- (only TDM WpC ble via RG,
ration without display) central RK,
data- BS,
base GS
Relocate: Re- #9419 – #9419 – – – – – DIG, ENT X WA,
activation, (only TDM WpC RG,
load configura- without display) RK,
tion BS,
GS
Terminal test *940 – *940 – – – U1 – DIG, ENT, – WA,
IPSC RG,
RK,
BS,
GS
MCID *84 MCID *84 – V – H – AN, DIG, ENT, – –
(local S0 S0, CMI, IPSC
WpC
function-
ality)
Flex call *508+Stn. no. 75508 *508 – V – H – AN, DIG, ENT, ––
S0, CMI, IPSC
Emergency *43+Trunk code 7543... *43.. – U – H – AN, DIG, ENT, X RK, Only for attendant
Trunk Access S0, CMI, IPSC BS
View call
charges (see
charge dis-
play)
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-7
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
B-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Hardware set- +/– ...(local pro- – +/–... X – – – Local ALL – RK From idle state: Call
tings cedure for CMI) Key parameters, speak-
er mode (if avail-
able)
From talk state: Vol-
ume
Hotel terminal *491+Stn. no. 75491 *491 – – – H – AN, DIG, ENT, X WA, Activate LED
S0, CMI, IPSC RK,
BS,
RG
Hotline – – – – – – – – AN, DIG, ENT, – – Hotline destination
S0, CMI, IPSC is defined for each
individual station in
the CDR.
Send mes- *68+(Stn. 7568... *68 – V, U RH, U1 Local AN, DIG, ENT, X RK, Without dialing call
sage (mes- no.)+Text no. RG feature S0, CMI, IPSC BS number in ringing
sage waiting) menu state
Cancel/an- #68 7668 #68 – – RH U1 – AN, DIG, ENT, X RK, Suffix dialing not
swer/display S0, CMI, IPSC BS permitted for DIG,
message S0.
(message Suffix dialing for
waiting) ENT, AN, CMI: 0 =
delete all sent and
received messag-
es, 1 = delete all
sent messages, 2 =
delete all received
messages, 3 = call
sender.
Fax waiting Only TDM work- – – – V – H – DIG, ENT – – Feature deleted by
message/an- point clients pressing the key
swering ma- with corre-
chine sponding key
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-9
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
B-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-11
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Night answer #44+ * or Stn. 7644 #44 – V, T RH U1 – AN, DIG, ENT, X RK,
off no. S0, CMI, IPSC BS
Repertory key/ – – – – V – – Speed DIG X – Key can be as-
DSS dialing signed an internal
key or external call
number.
Telephone locking
for external reperto-
ry key only.
Paging, see
speaker call to
a group
Park on *56+Park slot 7556 *56... – U, T – H Key, AN, DIG, ENT, – RH,
Menu S0, CMI, IPSC BR
Retrieve call #56+Park slot 7656 #56... – U, T – H Key, AN, DIG, ENT, – WA,
Menu S0, CMI, IPSC EG,
GS,
RK,
BS
Paging system *45+Stn. no. 7545... *45.. – – – AN, DIG, ENT, – –
(PSE comfort), S0, CMI, IPSC
paging
Paging system #45+Stn. no. 7645... #45.. – – – H – AN, DIG, ENT, – –
(PSE comfort), S0, CMI, IPSC
meet me
Account code *60+ACCT 7560... *60... – U – H –/man- AN, DIG, ENT, X WA, ACCT can also be
datory S0, CMI, IPSC RG, entered without
ACCT RK, service code follow-
possi- BS ing ext. line seizure.
ble
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
B-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Route seizure See numbering See See – V – – See AN, DIG, ENT, X – Telephone lock only
plan number- num- num- S0, CMI, IPSC permitted for sei-
ing plan bering bering zure of outgoing
plan plan lines.
Set callback *58 CCBS *58 – V, T RG U1 Local AN, DIG, ENT, – RH,
(local S0 active S0, CMI, IPSC BR,
WpC menu WA,
function- GS,
ality) RK,
BS
View or delete #58 CCBS #58... – U, T RH U1 Local AN, DIG, ENT, X RH,
callback re- (local S0 feature S0, CMI, IPSC BR,
quests WpC menu WA,
function- GS,
ality) RK,
BS
Initiate call- DP: Dial HOLD – – – GS – Drag& AN, DIG, ENT, – –
back (exclu- CMI, DTMF: (local S0 Drop, S0, CMI,
sive hold) Flash WpC menu IPSC, IPSI
TDM WpC with- function-
out display: ality)
Consultation
hold key
Call number *86 CLIR *86 – V, T RH U1 Fea- AN, DIG, ENT, X RK,
suppression (local S0 ture S0, CMI, IPSC BS
on, temp. WpC menu
function-
ality)
Call number #86 CLIP #86 – V, T RH U1 Fea- AN, DIG, ENT, X RK,
suppression (local S0 ture S0, CMI, IPSC BS
off, temp. WpC menu
function-
ality)
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-13
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Station num- *41+DID no. 7541... *41... – V – H – AN, DIG, ENT, X – This must be fol-
ber, assign for S0, CMI, IPSC lowed by seizure of
MUSAP external line.
Ring transfer *502+MULAP 75502 *502 – V, T – H – AN, DIG, ENT, X Only for member of
on S0, CMI, IPSC the executive MU-
LAP groups
Ring transfer #502+MULAP 76502 #502 – V, T – H – AN, DIG, ENT, X Only for member of
off S0, CMI, IPSC the executive MU-
LAP groups
Ringing group *81+Stn. no. 7581... *81... – U, V, – H – AN, DIG, ENT, X RK,
on T S0, CMI, IPSC BS
Ringing group #81 7681 #81 – U, V, RH H – AN, DIG, ENT, X RK,
off - all mem- T S0, CMI, IPSC BS
bers removed
Ringer cutoff – – *98 – V, T RH U1 Local DIG, IPSC X RK, A short advisory
on feature BS tone is activated.
The optical signals
are retained.
Ringer cutoff – – #98 – V, T RH U1 Local DIG, IPSC X RK,
off feature BS
Hunt group, *85 7585 *85 – V, T RH U1 Fea- AN, DIG, ENT, X RK, All hunt groups, join
join ture S0, CMI, IPSC BS = *85*
menu
Hunt group, #85 7685 #85 – V, T RH U1 Fea- AN, DIG, ENT, X RK, All hunt groups,
leave ture S0, CMI, IPSC BS leave = #85#
menu
Service menu – – – X, – – – – DIG, IPSC – BS Service key as for
T stopping and start-
ing procedure
Remote ser- *994+In- 75944 *994 – – – U1 – AN, DIG, ENT, – –
vice call dex+Suffix dial- S0, CMI, IPSC
ing
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
B-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
Silent monitor- *944+Stn. no. *944.. – – – – – AN, DIG, ENT, X WA, Only for selected
ing CMI RG, countries and for
BS, authorized stations
RK
Trunk flash on *51 – *51 – V – H – AN, DIG, ENT, X –
analog trunk CMI, IPSC
Silent ringing, –
see ringer cut-
off
Language se- – – *48 At login IPSC –
lection
Substitution 75 75 75 – – – – – ALL – –
code for ‘*’
Substitution 76 76 76 – – – – – ALL – –
code for ‘#’
System ad- – – *95... – – – H – DIG, IPSC See WA, Only for authorized
ministration notes RG, stations via access
RK, code.
BS User data is pro-
tected via tele-
phone lock feature.
System ad- – – *991... – – – – – DIG, IPSC – WA,
ministration, RG,
remote DTMF RK,
administration BS
and mainte-
nance, enable
(service sys-
tem)
Abbreviations:
● Call states: RH = idle, BR = ready, WA = digit input, BS = busy, RK = incoming call, RG = outgoing call, GS = call
● Key programming: V = key can be programmed with complete feature, U = key can be programmed to start procedure, T = key with
toggle functionality
● Menu level: H = Main menu, U1 = 1st submenu, U2 = 2nd submenu
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-15
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
B-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
Programmable
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-17
fcodes.fm
locking on
procedure
lock code
Code +
Status
Code
Code
Code
Service
via
Dialog
Fixed
bar
P31003-H3560-S100-3-7620, 03/06
B-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
1 The codes are valid for DTMF telephones. Substitution codes 75 and 76 must be entered instead of “*” and “#” for DP tele-
phones.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-19
fcodes.fm
P31003-H3560-S100-3-7620, 03/06
B-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
fcodes.fm
Codes for Activating/Deactivating Features
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual B-21
fcodes.fm
P31003-H3560-S100-3-7620, 03/06
B-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
Information on applications that can be used in HiPath 3000/5000 V6.0 can be found
> in the relevant product documentation.
Topic
HiPath 3000, page C-2
HiPath 5000, page C-3
HiPath ComScendo Service, page C-5
HiPath FM Managed Systems, page C-7
HG 1500, page C-8
optiClient 130 V5.0, page C-11
optiPoint 400, optiPoint 410, optiPoint 410 S, optiPoint 420, optiPoint 420 S, optiPoint 600 of-
fice, page C-13
HiPath AP 1120, page C-16
Middleware for Call Control, page C-17
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-1
portnos.fm
P31003-H3560-S100-3-7620, 03/06
C-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
HiPath 5000
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-3
portnos.fm
P31003-H3560-S100-3-7620, 03/06
C-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
HiPath ComScendo Service
Table C-3 HiPath ComScendo Service - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-5
portnos.fm
Table C-3 HiPath ComScendo Service - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
C-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
HiPath FM Managed Systems
Table C-4 HiPath FM Managed Systems - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-7
portnos.fm
C.5 HG 1500
P31003-H3560-S100-3-7620, 03/06
C-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
HG 1500
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-9
portnos.fm
P31003-H3560-S100-3-7620, 03/06
C-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
optiClient 130 V5.0
Table C-6 optiClient 130 V5.0 - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-11
portnos.fm
Table C-6 optiClient 130 V5.0 - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
C-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
optiPoint 400, optiPoint 410, optiPoint 410 S, optiPoint 420, optiPoint 420 S, optiPoint 600 office
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-13
portnos.fm
Table C-7 optiPoint 400, optiPoint 410, optiPoint 410 S, optiPoint 420, optiPoint 420 S,
optiPoint 600 office - Used IP Protocols and Port Numbers
P31003-H3560-S100-3-7620, 03/06
C-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
optiPoint 400, optiPoint 410, optiPoint 410 S, optiPoint 420, optiPoint 420 S, optiPoint 600 office
Table C-7 optiPoint 400, optiPoint 410, optiPoint 410 S, optiPoint 420, optiPoint 420 S,
optiPoint 600 office - Used IP Protocols and Port Numbers
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-15
portnos.fm
P31003-H3560-S100-3-7620, 03/06
C-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
portnos.fm
IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
Middleware for Call Control
Table C-9 Middleware for Call Control - IP Protocols and Port Numbers Used
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual C-17
portnos.fm
P31003-H3560-S100-3-7620, 03/06
C-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
The following values are for orientation only, and can vary depending on the traffic
> flow.
This supplement specifies the power requirement of the boards and components of the HiPath
3000 systems. In addition, information is provided on the power requirement of the different
workpoint clients, key modules and adapters.
With this information,
● the individual system power requirement can be identified.
● every system configuration can be checked to see whether the nominal output of the power
supply unit is sufficient or whether an additional power supply may be needed.
Topic
HiPath 3800 Board Power Requirement, page D-2
HiPath 3750 and HiPath 3700 Board Power Requirement, page D-4
HiPath 3550 Board Power Requirement, page D-6
HiPath 3350 Board Power Requirement, page D-8
HiPath 3500 Board Power Requirement, page D-10
HiPath 3300 Board Power Requirement, page D-12
Workpoint Clients, Key Modules and Adapter Power Requirements, page D-13
Checking Whether the Output of a Power Supply Unit is Sufficient, page D-16
Identifying the Primary System Power Requirement, page D-19
To ensure that a system’s dynamic capacity limit is not exceeded, the configuration
> can be tested using the project planning tool (Intranet: http://intranet.mch4.sie-
mens.de/syseng/perfeng/tools/hpt/index_en.htm).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-1
power_calc.fm
Table D-1 Nominal Output of the HiPath 3800 Power Supply Unit
You must check whether the total power requirement of the boards used and the
> connected workpoint clients of a system cabinet exceeds the maximum possible
LUNA2 output. Section D.8 contains a sample calculation.
P31003-H3560-S100-3-7620, 03/06
D-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
HiPath 3800 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-3
power_calc.fm
Table D-3 Nominal Output of the HiPath 3750 Power Supply Unit and HiPath 3700
You must check whether the total power requirement of the boards used and the
> connected workpoint clients of a system cabinet exceeds the maximum possible
UPSM output. Section D.8 contains a sample calculation.
Table D-4 HiPath 3750 and HiPath 3700 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
D-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
HiPath 3750 and HiPath 3700 Board Power Requirement
Table D-4 HiPath 3750 and HiPath 3700 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-5
power_calc.fm
Table D-5 Nominal Output of the HiPath 3550 Power Supply Units
You must check whether the total power requirement of the boards used and the
> connected workpoint clients exceeds the maximum possible output of the UPSC-D
with or without EPSU2. Section D.8 contains a sample calculation.
P31003-H3560-S100-3-7620, 03/06
D-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
HiPath 3550 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-7
power_calc.fm
Table D-7 Nominal Output of the HiPath 3350 Power Supply Units
You must check whether the total power requirement of the boards used and the
> connected workpoint clients exceeds the maximum possible output of the PSUP or
the UPSC-D with or without EPSU2. Section D.8 contains a sample calculation.
P31003-H3560-S100-3-7620, 03/06
D-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
HiPath 3350 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-9
power_calc.fm
Table D-9 Nominal Output of the HiPath 3500 Power Supply Units
You must check whether the total power requirement of the boards used and the
> connected workpoint clients exceeds the maximum possible output of the UPSC-DR
with or without EPSU2-R. Section D.8 contains a sample calculation.
P31003-H3560-S100-3-7620, 03/06
D-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
HiPath 3500 Board Power Requirement
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-11
power_calc.fm
Table D-11 Nominal Output of the HiPath 3300 Power Supply Units
You must check whether the total power requirement of the boards used and the
> connected workpoint clients exceeds the maximum possible output of the UPSC-DR
with or without EPSU2-R. A sample calculation is shown in Section D.8.
P31003-H3560-S100-3-7620, 03/06
D-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
Workpoint Clients, Key Modules and Adapter Power Requirements
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-13
power_calc.fm
Table D-13 Workpoint Clients, Key Modules and Adapter Power Requirements
P31003-H3560-S100-3-7620, 03/06
D-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
Workpoint Clients, Key Modules and Adapter Power Requirements
Table D-13 Workpoint Clients, Key Modules and Adapter Power Requirements
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-15
power_calc.fm
Caution
7 To guarantee smooth system operation, the nominal output of the power supply unit
at the 5-V output and at the –48-V output must be greater than the respective sec-
ondary power requirement.
Procedure
Proceed as follows to identify the secondary power requirement of a system:
1. Determine secondary power requirement at the 5-V output
P31003-H3560-S100-3-7620, 03/06
D-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
Checking Whether the Output of a Power Supply Unit is Sufficient
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-17
power_calc.fm
P31003-H3560-S100-3-7620, 03/06
D-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
power_calc.fm
Identifying System Power Requirements
Identifying the Primary System Power Requirement
Procedure
Proceed as follows to identify the primary power requirement of a system:
1. Determine overall secondary power requirement
= the result should be multiplied by the factor 1.2 to allow for the degree of efficiency of
the power supply.
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual D-19
power_calc.fm
P31003-H3560-S100-3-7620, 03/06
D-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
snmpd.fm
Notes for editing the file snmpd.cnf
Introduction
E.1 Introduction
The SNMP parameters required for HiPath 5000 are defined when installing the FM Reporting
Client (SNMP Master Agent). This refers to the trap destinations and the names of the HiPath
Fault Management desktop communities.
The FM Reporting Client does not have its own user interface. The SNMP parameters defined
during installation may only be changed by uninstalling and then reinstalling the FM Reporting
Client.
Users with sufficient knowledge of SNMP can change trap destinations and community names
by editing the file snmpd.cnf. The file can be found in the installation directory of the FM Re-
porting Client.
The following notes on editing the file snmpd.cnf are intended exclusively for users
> with sufficient knowledge of SNMP.
Note: The syntax of entries in the FM Reporting Client configuration file (SNMP mas-
ter agent) is appended to the element description in the SNMP-TARGET-MIB (RFC
3413 – Chapter 4, cf. http://www.zvon.org).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual E-1
snmpd.fm
● snmpNotifyTag
Designation that must correspond with the snmpTargetAddrTagList (snmpTagetAd-
drEntry), so that a trap can be sent.
The value is always "hipath".
● snmpNotifyType
Type of traps that are to be sent (trap, about).
For HiPath 5000 always “trap”.
● snmpNotifyStorageType
Always “nonVolatile” (persistent storage necessary).
snmpTargetAddrEntry <snmpTargetAddrName> <snmpTargetAddrTDomain> <sn-
mpTargetAddrTAddress> <snmpTargetAddrTimeout> <snmpTargetAddrRetry-
Count> <snmpTargetAddrTagList> <snmpTargetAddrParams> <snmpTargetAd-
drStorageType> <snmpTargetAddrTMask> <snmpTargetAddrMMS>
● snmpTargetAddrName
Any unambiguous identifier for the entry.
String with 1-32 characters.
● snmpTargetAddrTDomain
Transport type for the entry.
String: snmpUDPDomain or snmpIPXDomain.
● snmpTargetAddrTAddress
Destination address for traps.
The format depends on the entry snmpTargetAddrTDomain.
For snmpUDPDomain: IP address + port (for example 192.132.123.98:162), whereby 0
may also be entered as a port. In this case the default port will be used.
● snmpTargetAddrTimeout
Timeout: Default is 1500. For HiPath 5000, 100 is used.
● snmpTargetAddrRetryCount
Retry count: Default is 3.
● snmpTargetAddrTagList
Designation that must correspond with a snmpNotifyTag (snmpNotifyEntry) so that
a trap can be sent to the given address.
The value is always "hipath".
● snmpTargetAddrParams
Designation that refers to an entry in a snmpTargetParamsEntry (snmpTarget-
ParamsName).
The value is always "v1Params".
● snmpTargetAddrStorageType
Always “nonVolatile” (persistent storage necessary).
P31003-H3560-S100-3-7620, 03/06
E-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
snmpd.fm
Notes for editing the file snmpd.cnf
Trap Destination
● snmpTargetAddrTMask
Transport mask is always 255.255.255.255:0.
● snmpTargetAddrMMS
Maximum message size is always 2048 (bytes).
snmpTargetParamsEntry <snmpTargetParamsName> <snmpTargetParamsMPMod-
el> <snmpTargetParamsSecurityModel> <snmpTargetParamsSecurityName>
<snmpTargetParamsSecurityLevel> <snmpTargetParamsStorageType>
● snmpTargetParamsName
Any unambiguous identifier for the entry.
String with 1-32 characters.
The value is always "v1Params".
● snmpTargetParamsMPModel
Message processing model: 0 (SNMPv1), 1 (SNMPv2c), 2 (SNMPv2u, SNMPv2*),
3 (SNMPv3).
1 for "v1Params".
● snmpTargetParamsSecurityModel
Security Model: snmpv1, snmpv2c, snmpv2s, ...
snmpv1 for "v1Params".
● snmpTargetParamsSecurityName
Security name within the configuration file.
The value is always “public”.
● snmpTargetParamsSecurityLevel
Security level is always “noAuthNoPriv”.
● snmpTargetParamsStorageType
Always “nonVolatile” (persistent storage necessary).
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual E-3
snmpd.fm
P31003-H3560-S100-3-7620, 03/06
E-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
snmpd.fm
Notes for editing the file snmpd.cnf
Consequences for the file snmpd.cnf
This means that any entries to be made must always be in the following format:
1. Communities
(Definition: There is exactly one read and exactly one write community.)
a) Read Community
snmpCommunityEntry t001 <community-string> public localSnmpID -
- nonVolatile
a) Write Community
snmpCommunityEntry t002 <community-string> public localSnmpID -
- nonVolatile
2. Trap Destinations
snmpTargetAddrEntry <lfd.-Nr.> snmpUDPDomain <IP-Adresse>:<Port>
100 3 hipath v1Params nonVolatile 255.255.255.255:0 2048
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual E-5
snmpd.fm
P31003-H3560-S100-3-7620, 03/06
E-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shabb.fm
Abbreviations
Abbreviations
A
ADPCM Adaptive Difference Pulse Code Modulation
ALUM Trunk failure transfer
AMHOST Administration and Maintenance via HOST
ANI Automatic Number Identification
ANI4R Automatic Number Identification Rack
APS System Program System
B
BC Basic Cabinet (HiPath 3750/HiPath 3700)
BHCA Busy Hour Call Attempts
BSG Add-on device
BSG Upright battery housing
C
CABLU Cabling Unit
CAS Channel Associated Signaling
CBCC Central Board with Coldfire Com
CBCP Central Board with Coldfire Point
CBCPR Central Board with Coldfire Pro
CBRC Central Board Rack Com
CBSAP Central Board Synergy Access Platform
CCBS Completion of Calls to Busy Subscribers
CDB Customer Database
CDB Customer Database
CLA Customer License Agent
CLC Customer License Client
CLIP Calling Line Identification Presentation
CLIR Calling Line Identification Restriction
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Y-1
hp3hp5shabb.fm
Abbreviations
P31003-H3560-S100-3-7620, 03/06
Y-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shabb.fm
Abbreviations
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Y-3
hp3hp5shabb.fm
Abbreviations
P31003-H3560-S100-3-7620, 03/06
Y-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shabb.fm
Abbreviations
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Y-5
hp3hp5shabb.fm
Abbreviations
P31003-H3560-S100-3-7620, 03/06
Y-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
Index X
ANI4 (for selected countries only) 3-368
contact assignments 3-370
Numerics installation instructions 3-371
16SLA 3-357 interfaces 3-368
connection conditions 3-359 LED statuses 3-368
contact assignments 3-358 ANI4R (for selected countries only) 3-372
interfaces 3-358 contact assignment 3-373
4SLA/8SLA 3-357 figure 3-372
connection conditions 3-359 interfaces 3-372
contact assignments 3-357 Announcement and music modules 3-374
interfaces 3-357 APPCU adapter 3-140, 3-143
802.1p field 13-4 APS stamp 12-15
8SLAR APS Transfer 12-12
contact assignments 3-360 APS transfer 12-11
interfaces 3-360 Archive file (.arc) 12-108
module specifications 3-361 Assigning Station Numbers 5-4, 5-13, 5-21
8-slot cabinets (HiPath 3700) 4-139 Attendant Console Versions 10-80
8-slot cabinets (HiPath 3750) 4-114
B
A B channel modem 12-92
AC outlet (for U.S. only) Backing up system components 12-19
HiPath 3500/HiPath 3300 4-189 Backplane HiPath 3700
HiPath 3550/HiPath 3350 4-169 basic cabinet 4-139
HiPath 3700 4-130 expansion cabinet 4-140
HiPath 3750 4-90 jacks 4-140
HiPath 3800 4-6 Backplane HiPath 3750
Access Security 12-98 basic cabinet 4-114
Accidents, reporting 1-12 expansion cabinet 4-115
Adapter cable C39195-A7269-B625 3-94 jacks 4-115
ALUM4 3-362 Backplane HiPath 3800
basic structure 3-365 basic cabinet 4-52
contact assignments 3-363 connector panels with CHAMP jack (for
interfaces 3-363 U.S. only) 4-63
AMHOST 12-103 connector panels with RJ45 jacks 4-61
AMOM 3-366 connector panels with SIPAC 1 SU con-
Assignment 3-367 nectors 4-64
Variants 3-366 expansion cabinet 4-55
Analog boards for tie trunk traffic SIVAPAC connector 4-58
TIEL 3-262 Backup Manager 12-6, 12-19
TMEW2 3-325 Bandwidth 13-2
Analog modem 12-92 Bandwidth control 2-29
Base station power supply 3-176
Base stations 11-2
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-1
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-3
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-5
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-7
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-9
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P Power supply
Part numbers external applications 3-391, 3-393,
backplanes (HiPath 3700) 4-142, 4-143 3-395
backplanes (HiPath 3750) 4-117, 4-118 HiPath 3350 3-68
cabinets (HiPath 3700) 4-142, 4-143 HiPath 3500/HiPath 3300 3-78
cabinets (HiPath 3750) 4-117, 4-118 HiPath 3550/HiPath 3350 3-73
CABLUs, open-end cables (HiPath 3700) HiPath 3750/HiPath 3700 3-84
4-144 HiPath 3800 3-57
CABLUs, open-end cables (HiPath 3750) NT (HiPath 3550/HiPath 3500) 3-355
4-119 NT (HiPath 3750/HiPath 3700) 3-346
CABLUs, open-end cables (HiPath 3800) Presence Manager 6-8
4-58, 4-65 trace files 12-30
connection cable (HiPath 3750) 4-117 Privacy and Data Security 1-14
connection cables (HiPath 3700) 4-142, Project planning tool 2-23, 10-34
4-143 Protocols 13-2
connection cables (HiPath 3750) 4-118 PSUP 3-68
Password 12-98 Figure 3-68
Password type, defining 5-7, 5-15, 5-23
PBXXX 3-137 Q
administration 3-137 Quality of Service QoS 13-4
connection cable 3-140, 3-143 R
front panel 3-138 Ranges
setup using HiPath 3000 Manager E CorNet N/CorNet NQ 2-48
3-137 telephone interfaces 2-48
seven segment display 3-139 trunk connection 2-48
PCM segments for HiPath 3750/HiPath 3700 REAL 3-391
4-158 cable and connector assignment 3-394
PCM segments for HiPath 3800 4-46 electr. characteristics of relays 3-392
PDM1 3-102, 3-108 installation location 3-392
PDMX 3-246 power failure transfer 3-391
PDS file 6-53, 12-4 relay contacts 3-393
Peripheral boards 3-3 special connections 3-391
PFT1/PFT4 (not for U.S.) 3-388 REALS 3-395
assignment 3-390 cable and connector assignment 3-397
installation location 3-389 electrical characteristics of relays 3-395
Pin assignments of the V.24 sockets 3-408 slot 3-397
Port numbers C-1 special connections via relay 3-395
Power failure transfer 3-391 trunk failure transfer 3-395
Power plug (for U.S. only) HiPath 3800 4-24 Reinitialization 5-5, 5-14, 5-22
Power requirement (boards, workpoint cli- Reload 5-6, 5-15, 5-23
ents, adapter) D-1 Remote access immediately after installation
12-94
Remote administration 12-93
Remote connection, controlled release 12-96
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-11
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-13
hp3hp5shIX.fm
Index
P31003-H3560-S100-3-7620, 03/06
Z-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
hp3hp5shIX.fm
Index
TMDID (for U.S. only) 3-317 TMST1 (for U.S. only) 3-340
cable and connector assignment 3-318 adapter 3-342
front panel 3-318 figure 3-340
LED statuses 3-317 LED statuses 3-341
LEDs 3-318 Trace options
switches 3-317 Customer License Agent (CLA) 12-46
TMDID8 (for U.S. only) 3-322 Customer License Manager (CLM)
cable and connector assignment 3-324 12-46
figure 3-322 HiPath 3000 12-29
LED statuses 3-323 HiPath Inventory Manager 12-47
switches 3-323 HiPath Manager PCM Trace Monitor
TMEW2 3-325 12-30
cable and connector assignment 3-327 HiPath Software Manager 12-47
front panel 3-326 in connection with SRTP 12-37
LED statuses 3-327 Traffic capacity (in Erlangs)
LEDs 3-326 HiPath 3500/HiPath 3300 4-199
TMGL4 (for U.S. only) 3-329 HiPath 3550/HiPath 3350 4-186
contact assignment 3-330 HiPath 3750/HiPath 3700 4-161
figure 3-329 HiPath 3800 4-50
TMGL4R (for U.S. only) 3-331 Trunk diagnostics 12-26
contact assignment 3-332 Trunk failure transfer 3-362, 3-388, 3-395
figure 3-331 Trunk status 12-26
interfaces 3-331 TS2 (not for U.S) 3-352
TMGL8 (for U.S. only) 3-333 interface assignments 3-354
cable and connector assignment 3-334 interfaces 3-353
figure 3-333 NT cable set for Spain/Portugal 3-356
LED statuses 3-334 NT connection 3-355
switches 3-333 S2M trunk connection 3-355
TML8W (not for U.S.) 3-335 TS2R (not for U.S) 3-352
cable and connector assignment 3-337 interface assignments 3-354
figure 3-335 interfaces 3-353
jumpers for CDR 3-335 NT cable set for Spain/Portugal 3-356
LED statuses 3-336 NT connection 3-355
TMQ4 (for U.S. only) 3-338 S2M trunk connection 3-355
contact assignment 3-339 TST1 (for U.S. only) 3-350
figure 3-338 contact assignment 3-351
TMS2 (not for U.S) 3-343 figure 3-350
jumper 3-344
LED statuses 3-345 U
NT connection 3-346 Uninterruptible power supply unit HiPath
S2M networking 3-349 3500/HiPath 3300
S2M trunk connection 3-346 see UPSC-DR 3-78
SU connector assignment 3-344
switches, displays 3-343
P31003-H3560-S100-3-7620, 03/06
HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual Z-15
hp3hp5shIX.fm
Index
Uninterruptible power supply unit HiPath V.24 interfaces (HiPath 3700) 4-140
3550/HiPath 3350 V.24 interfaces (HiPath 3750) 4-115
see UPSC-D 3-73 V24/1 (not for U.S.) 3-407
Uninterruptible power supply unit HiPath figure 3-407
3750/HiPath 3700 Version hub 12-15
see UPSM 3-84 Voice over IP 10-37
Uninterruptible power supply unit HiPath
3800 W
see LUNA2 3-57 Web-based management (WBM) 3-101,
Uninterruptible Power Supply Unit HiPath 3-107, 3-245, 6-6
5000 6-64 WLAN 10-79
Updating HG 1500 12-16 Workpoint client power requirement D-1
Updating system software 12-16 Workpoint clients 10-1
Upgrade Manager 12-16
Upgrading HiPath 3000 (HW/SW) 9-29
Upgrading HiPath 5000 6-46
Upgrading the system software 12-11
UPS P 500 6-64
UPSC-D 3-73
bridging times 3-74
connectors 3-77
figure 3-75
switches and indicators 3-76
UPSC-DR 3-78
battery pack for HiPath 3500/HiPath
3300 9-13
bridging times 3-79
connectors 3-83
figure 3-80
switches and indicators 3-82
UPSM 3-84
battery pack for HiPath 3700 9-13
bridging times 3-86
figure (-A100) 3-88
figure (-S100) 3-87
USB 1.1 interface 10-15
USB V.24 Adapter 3-406
User groups and their access rights 12-101
V
V.24 adapter 3-409
V.24 cable, assignment 3-410
V.24 connector assignment 3-408
V.24 interfaces (HiPath 3550, HiPath 3350)
3-407
P31003-H3560-S100-3-7620, 03/06
Z-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Service Manual
www.siemens.com/hipath