HATCH PDS
PRESSKIT
OVERPRESSURE KIT
PRESSURISATION
CONTROL SYSTEMS
FOR STAIRWELLS, LOBBIES AND ESCAPE ROUTES
EN-12101-6
Smoke and heat control
systems: Specifications
for pressure differential systems
SODECA has focussed its business on manufacturing industrial
fans, ventilation systems and smoke extractors for use in case of
Sodeca has begun a new stage Without a doubt, the most important factor in achieving our
objectives is the human factor, the great professionals who work
in the study and design of new
at your service, offering not only ventilation equipment but also
trends in ventilation which will solutions to any ventilation requirement our customers may have.
help to preserve the environment
and to make the energy savings We offer you the option of visiting our facilities in Sant Quirze de
that are such a major concern for Besora, with over 16,0002 square metres of built area, where you
today's society. will be able to see our fans being manufactured to the highest
quality standards, complying with the ISO and AMCA standards.
EFFICIENT WORK
SODECA S.L.U. has its main facilities in E-08580 SANT QUIRZE DE BESORA
PRESSURISATION
CONTROL SYSTEMS
KIT BOXPDS
• This consists of the BOXPDS control panel, a CJHCH ventilation unit
and a Damper kit with built-in optical smoke detector.
· Easy to install
· Compact and self-sufficient solution
· Preventive maintenance
· Easy start-up
· Safe and functional installation
BOXPDS BOXPDS
• Frequency inverter.
• High precision differential pressure probe.
• Electrical switchboard with magneto-thermal circuit-breakers and mains
power cut indicator.
• Electronic control for managing alarms, maintenance, ModBUS RTU port
for connection to BMS (Building management systems) and DAMPER-
based control.
• Certified battery-powered power source to guarantee supply to the
control equipment if there is a mains power failure.
Control panel:
• External Control panel for displaying
pressure in real time, alarm pilot lights and
manual system activation
+50 Pa +50 Pa
Order code
Technical characteristics
KIT BOXPDS
Examples of use
BOXPDS DAMPER
HATCH PDS
This consists of a HATCH-S ventilation unit with motorised hatch opening and a
BOXPDS control panel
Opening system:
• Motorised opening arms, with IP-65 canned drive.
• Power supply voltage of 230 V AC 50Hz or 24V DC.
• Reinforced system, guaranteed for over 10,000 maximum load operations.
• Maximum load 1000 Nw.
• Automatic opening via external control input (fire control panel, smoke detector,
manual switch, etc)
• Control system not included.
• Manual opening for regulating environmental ventilation via a switch.
• Limit switch in place to indicate position of hatch.
Fan:
• HCT series fans.
• Sheet steel tubular casing with anticorrosive finish in polyester resin.
• Impellers made from cast aluminium.
Motor:
• IE2 efficiency motors for capacities equal to or over 0.75kW and below 7.5kW.
• IE3 efficiency motors for capacities equal to or over 7.5kW.
• Class F motors, with ball bearings, IP55 protection.
• Three-phase 230/400V-50Hz (up to 5.5 HP) and 400/690V -50Hz (power over
5.5 HP)
• Fan working temperature: -25ºC +50ºC
Finish:
• Anticorrosive galvanized sheet steel
On request:
• Equipped with F-300 and F-400 certified fans
• Reversible Pressurisation equipment for smoke extraction when necessary.
• Finish in anticorrosive paint with polyester resin.
BOXPDS
• Frequency inverter.
• Highly precise differential pressure probe.
• Electrical switchboard with magneto-thermal circuit-breakers and mains power
cut indicator.
• Electronic control for managing alarms, maintenance, ModBUS RTU port for
connection to BMS (Building management systems) and DAMPER-based
control.
• Certified battery-powered power source to guarantee supply to the control
equipment if there is a mains power failure.
+50 Pa
Control panel:
• External Control panel for displaying the pressure in real time,
alarm pilot lights and manual system activation.
Order code
Technical characteristics
Model Speed Maximum admissible current Installed Maximum Sound pressure Weight
(r/min) (A) power airflow level approx.
230V 400V 690V (kW) (m3/h) dB(A) (Kg)
HATCH PDS-40-2T-1 2850 3.15 1.80 0.75 6115 72 184
HATCH PDS-40-2T-1.5 2880 4.70 2.70 1.10 7050 73 188
HATCH PDS-45-2T-2 2880 5.90 3.40 1.50 9405 75 193
HATCH PDS-45-2T-3 2840 8.70 5.00 2.20 11325 77 194
HATCH PDS-50-2T-2 2880 5.90 3.40 1.50 10100 77 197
HATCH PDS-50-2T-3 2840 8.70 5.00 2.20 11925 78 199
HATCH PDS-50-2T-4 2880 11.20 6.50 3.00 13860 79 206
HATCH PDS-50-2T-5.5 2870 9.30 5.40 4.00 15900 80 222
HATCH PDS-56-2T-5.5 2870 9.50 5.50 4.00 18840 85 226
HATCH PDS-56-2T-7.5 2910 10.60 6.14 5.50 22510 86 237
HATCH PDS-56-4T-2 1440 6.20 3.60 1.50 15020 72 205
HATCH PDS-63-4T-3 1425 9.00 5.20 2.20 22460 73 262
HATCH PDS-63-4T-4 1430 11.40 6.60 3.00 24460 74 271
HATCH PDS-63-6T-1 940 4.70 2.70 0.75 16025 63 252
HATCH PDS-80-4T-3 1425 9.00 5.20 2.20 25545 79 280
HATCH PDS-80-4T-4 1430 11.40 6.60 3.00 30410 80 289
HATCH PDS-80-4T-5.5 1440 8.40 4.80 4.00 32940 81 295
HATCH PDS-80-4T-7.5 1460 12.60 7.30 5.50 39820 82 311
HATCH PDS-80-6T-1.5 945 5.50 3.20 1.10 21580 69 279
HATCH PDS-80-6T-2 945 7.40 4.30 1.50 26090 70 288
HATCH PDS-90-4T-7.5 1460 12.60 7.30 5.50 46325 88 392
HATCH PDS-90-4T-10 1460 17.70 10.20 7.50 50315 89 403
HATCH PDS-90-4T-15 1460 22.00 12.70 11.00 59610 90 456
HATCH PDS-90-6T-3 950 9.50 5.50 2.20 34055 75 365
HATCH PDS-90-6T-4 970 13.50 7.80 3.00 39055 76 391
HATCH PDS-100-4T-10 1460 17.70 10.20 7.50 57650 90 413
HATCH PDS-100-4T-15 1460 22.00 12.70 11.00 66505 91 466
HATCH PDS-100-6T-5.5 970 11.00 6.40 4.00 47955 81 413
HATCH PDS-100-6T-7.5 970 12.40 7.20 5.50 53545 82 420
HATCH PDS-40-2T-1 16 0.75 A S NO 1.00 41.5% 48.1 0.933 4420 32.19 2850
HATCH PDS-40-2T-1.5 20 1.1 A S NO 1.00 33.6% 38.9 1.445 5180 34.43 2884
HATCH PDS-45-2T-2 16 1.5 A S NO 1.00 35.9% 40.8 1.688 6802 32.70 2896
HATCH PDS-45-2T-3 22 2.2 A S NO 1.01 37.7% 41.6 2.405 8144 40.86 2854
HATCH PDS-50-2T-2 8 1.5 A S NO 1.00 35.9% 40.3 2.014 6731 39.48 2876
HATCH PDS-50-2T-3 12 2.2 A S NO 1.01 36.8% 40.5 2.586 7884 44.29 2843
HATCH PDS-50-2T-4 16 3 A S NO 1.01 34.3% 37.3 3.381 8962 47.55 2885
HATCH PDS-50-2T-5.5 20 4 A S NO 1.01 32.6% 35.1 4.131 9537 51.91 2885
HATCH PDS-56-2T-5.5 16 4 A S NO 1.01 45.4% 47.8 4.202 12896 54.34 2883
HATCH PDS-56-2T-7.5 22 5.5 A S NO 1.01 41.2% 42.6 6.055 15917 57.53 2913
HATCH PDS-56-4T-2 36 1.5 B T NO 1.00 45.7% 50.7 1.665 13581 20.60 1445
HATCH PDS-63-4T-3 32 2.2 B T NO 1.00 62.0% 65.9 2.443 20324 27.38 1430
HATCH PDS-63-4T-4 38 3 B T NO 1.00 57.8% 60.9 3.270 24239 28.64 1440
HATCH PDS-63-6T-1 38 0.75 B T NO 1.00 48.4% 54.4 1.099 15880 12.29 942
HATCH PDS-80-4T-3 12 2.2 C S NO 1.00 47.1% 51.0 2.413 16923 24.69 1430
HATCH PDS-80-4T-4 16 3 C S NO 1.00 41.1% 43.8 3.686 20444 27.19 1432
HATCH PDS-80-4T-5.5 18 4 C S NO 1.00 41.2% 43.5 4.246 22304 28.78 1448
HATCH PDS-80-4T-7.5 26 5.5 B T NO 1.00 63.0% 64.5 5.914 35186 38.92 1465
HATCH PDS-80-6T-1.5 18 1.1 C S NO 1.00 35.4% 40.8 1.389 14613 12.35 951
HATCH PDS-80-6T-2 26 1.5 B T NO 1.00 57.5% 62.1 1.825 23053 16.71 950
HATCH PDS-90-4T-7.5 18 5.5 C S NO 1.00 44.1% 45.2 6.749 31521 34.72 1460
HATCH PDS-90-4T-10 22 7.5 C S NO 1.01 38.9% 39.2 9.154 35009 37.36 1463
HATCH PDS-90-4T-15 30 11 B T NO 1.01 67.1% 67.1 11.526 52205 54.45 1463
HATCH PDS-90-6T-3 24 2.2 C S NO 1.00 38.0% 41.5 2.832 23831 16.58 950
HATCH PDS-90-6T-4 30 3 B T NO 1.00 58.8% 61.6 3.698 34203 23.37 971
HATCH PDS-100-4T-10 16 7.5 C S NO 1.00 41.3% 41.4 9.606 37591 38.73 1461
HATCH PDS-100-4T-15 22 11 C S NO 1.01 43.6% 43.5 12.145 44571 43.65 1461
HATCH PDS-100-4T-20 28 15 B T NO 1.01 64.1% 63.8 16.091 66559 56.95 1462
HATCH PDS100-6T-5.5 26 4 B T NO 1.00 57.6% 59.7 4.671 42042 23.50 973
HATCH PDS-100-6T-7.5 32 5.5 B T NO 1.00 56.3% 57.9 5.690 53520 22.00 975
Acoustic features
The specified values are determined according to free field measurements of sound levels in dB(A) at an equivalent distance of twice the fan’s
span plus the impeller’s diameter, with a minimum of 1.5 m.
Sound power Lw(A) spectrum in dB(A) via frequency band in Hz.
Modelo 63 125 250 500 1000 2000 4000 8000 Modelo 63 125 250 500 1000 2000 4000 8000
40-2-1 44 65 72 77 80 76 69 58 80-4-4 54 74 82 87 89 86 79 71
40-2-1.5 45 66 73 78 81 77 70 59 80-4-5.5 54 74 82 87 89 86 79 72
45-2-2 47 68 75 80 83 79 72 61 80-4-7.5 55 75 83 88 90 87 80 73
45-2-3 49 70 77 82 85 81 74 63 80-6-1.5 47 64 72 77 79 76 69 58
50-2-2 52 72 80 85 87 84 77 66 80-6-2 48 65 73 78 80 77 70 59
50-2-3 53 73 81 86 88 85 78 67 90-4-7.5 57 78 85 90 93 89 82 71
50-2-4 54 74 82 87 89 86 79 68 90-4-10 56 77 84 89 92 88 81 70
50-2-5.5 55 75 83 88 90 87 80 69 90-4-15 58 79 86 91 94 90 83 72
56-2-5.5 60 80 88 93 95 92 85 74 90-6-3 54 68 75 80 83 79 72 61
56-2-7.5 61 81 89 94 96 93 86 75 90-6-4 55 70 77 82 85 81 74 63
56-4-2 47 67 75 80 82 79 72 61 100-4-10 60 80 88 93 95 92 85 74
63-4-3 50 68 76 81 83 80 75 64 100-4-15 59 79 87 92 94 91 84 73
63-4-4 51 69 77 82 84 81 76 65 100-4-20 61 81 89 94 96 93 86 75
63-6-1 41 60 68 73 75 72 65 55 100-6-5.5 62 71 79 84 86 83 76 65
80-4-3 56 75 83 89 90 87 81 70 100-6-7.5 63 72 80 85 87 84 77 66
Dimensions in mm
HATCH PDS
BOXPDS
Model A B C
BOXPDS 900 650 280
PRESSKIT Pressurisation equipment for lobbies, compliant with
DM 30/11/1983 and the European Standard EN 12101-6
PRESSKIT systems have one or more fans. In the event of fire, they are activated to exert
an overpressure (pressure differential) of 50Pa in the safe areas and to prevent smoke
entering the escape routes to be used for evacuating people.
Common characteristics:
• Pressure is self-regulated throughout the lobby.
• Brushless E.C. 24VDC fans with maximum airflow of 2100m3/H.
• Maintain overpressure (pressure differential) of 50Pa in lobbies.
Equipment control:
• S Models: Simplified adjustment of the ventilation unit by pressure probe with built-in
PID signal regulator.
• P Models: PLC control with multiple inputs, outputs, alarms and fan adjustment by PID
signal.
Certified: NR331151 • Delay in turning on the equipment based on the status of the fire doors.
• Power supply panel with 18Ah batteries to provide operating power for over two hours.
• Equipment is easily connected.
• All parameters can quickly be adjusted and configured using the keyboard and LCD
screen.
• MANUAL system activation button.
• Real time display of pressure in the safe area and status of equipment.
+50 Pa
Order code
PRESSKIT ONE P
Technical characteristics
Maximum Maximum LpA Total Total Working Nominal duct
Model Speed Total power Weight Protection
airflow pressure irradiated 3m voltage current temperature diameter
(m3/h) (Pa) (rpm) dB(A) (V) (A) (W) (kg) (IP) (ºC) (mm)
PRESSKIT ONE 2100 180 1800 65 24VDC 4.8 115 6.8 42 -25 to +60 310
PRESSKIT TWIN 4100 180 1800 68 24VDC 9.6 230 13.6 42 -25 to +60 310
Dimensions in mm
Accessories
Voltage tester
for output from
power supply and
Alarm Battery tester batteries using
push-button RJ45 connector.
OVERPRESSURE KIT
The system of pressurising staircases, escape routes and refuges makes it possible to control the
airflow automatically and to maintain a differential pressure of 50 Pa in a single stage, in compliance
with standard UNE EN 12101-6-2006.
STAIRWELL OVERPRESSURE KIT
Three-phase equipment STAIRWELL OVERPRESSURE KIT
• Stairwell overpressure kit made up of control panel (BOXPRES KIT) and outlet units (CJHCH or
CJBD), for the pressurisation of the stairwells and escape routes. Also available for single-phase
NEOLINEO and CJBC equipment.
BOXPRES
• The proper operation of the pressurisation systems depends not only on correct design but also on
proper regulation performed by the system. It is therefore of vital importance to have calibrated and
highly-precise regulating components that make it possible to manage the two situations when there is
a fire, in a rapid and stable manner.
• The BOXPRES control panel not only satisfies the most demanding requirements, it also simplifies the
work of the installer to the greatest possible extent.
Includes:
OVERPRESSURE KIT
WITH RESERVE FAN
• Frequency inverter programmed to 50 Pa.
• Differential pressure probe.
• Magneto thermal.
• Line and fault LED.
• Check button.
BOXPRES:
• Equipment with all its interconnections made and tested.
• Ready to work and control the pressure of the installation.
• Possibility of checking the installation so as to prevent faults.
• Only the power cable, the impulsion fan and the fire signal need to be connected.
Order code
KIT SOBREPRESION II-6240-BOX 400 Vac III 400 Vac III TWIN-12/12-6T-1.5 6240 55
KIT SOBREPRESION II-9520-BOX 400 Vac III 400 Vac III TWIN-15/15-6T-3 9520 54
KIT SOBREPRESION II-12900-BOX 400 Vac III 400 Vac III CJHCH/DUPLEX-56-4T-1-H 12900 60
KIT SOBREPRESION II-17000-BOX 400 Vac III 400 Vac III CJHCH/DUPLEX-63-4T-1.5-H 17000 61
SI-PRESIÓN TPDA
SI-PRESSURE TPDA w/DISPLAY
BOXPRES KIT-3A 230V AC 230 V AC II 230 V AC II
BOXPRES KIT-10A 230V AC 230 V AC II 230 V AC II
BOXPRES KIT-0.75KW 230V AC 230 V AC II 230 V AC III
BOXPRES KIT-1.5KW 230V AC 230 V AC II 230 V AC III
BOXPRES KIT-0.75KW 400V AC 400 V AC III 400 V AC III
BOXPRES KIT-1.5KW 400V AC 400 V AC III 400 V AC III
BOXPRES KIT-2.2KW 400V AC 400 V AC III 400 V AC III
BOXPRES KIT II - 1.5KW 400V AC 400 V AC III 400 V AC III
BOXPRES KIT II - 2.2KW 400V AC 400 V AC III 400 V AC III
Dimensions in mm
CJHCH CJBD
TWIN CJHCH/DUPLEX
Model A B C
TWIN-12/12 1103 1139 610 Model A B C D1
TWIN 15/15 1279 1639 698 CJHCH/DUPLEX-56/63 825 1650 550 690
NEOLINEO CJBC
Model A B C C1 C2 øD E
NEOLINEO-200 300 234.5 260.5 125.5 235 196 140 Model A B H K L øO V v1 X x1
NEOLINEO-315 448 361.5 392.5 188.5 359 312 220.5 CJBC-2828-6M-1/3 696 645 460 290 320 15 755 725 445 100
M 12 x 1.5mm
Fire signal connection
Regulator Pressure connection
Probe
Pressure connection
BOXPRESS KIT SOBREPRESIÓN II
M 12 x 1.5mm
Fire signal connection
Pressure connection