0% found this document useful (0 votes)
538 views30 pages

g60 PDF

The document provides an instruction manual for a GSM home security alarm system, outlining its key features such as touchscreen keypad, wireless zones, SMS notifications, temperature display, and backup battery. It also describes how to operate the system including arming/disarming, making calls, setting user codes and phone numbers for alarm calls and status reports. Technical specifications are provided for the system's power requirements, wireless frequencies, and environmental operating conditions.

Uploaded by

Fadi Malkawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
538 views30 pages

g60 PDF

The document provides an instruction manual for a GSM home security alarm system, outlining its key features such as touchscreen keypad, wireless zones, SMS notifications, temperature display, and backup battery. It also describes how to operate the system including arming/disarming, making calls, setting user codes and phone numbers for alarm calls and status reports. Technical specifications are provided for the system's power requirements, wireless frequencies, and environmental operating conditions.

Uploaded by

Fadi Malkawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

GSM INTRUSION ALARM SYSTEM

INSTRUCTION MANUAL

GSM - PSTN - SMS - TOUCH


GSM Wireless Security Alarm System
SECURE YOUR HOME AND BUSINESS

Printed in Shenzhen
RE: G60-GSM-August-2013
Key Features
• Smart touch keypad with 4 line message LCD display
• Quad-band GSM communication, works with SIM card
• Calender, five personal emergency phone numbers
• One central monitoring station phone number
• Alarm notification via phone call or SMS
• Built-in speaker and microphone
• Remote two-way intercom
• Extra SMS phone number for system's status
• Alarm memo, entry delay, exit delay
• Hybrid alarm, 30 wireless zones, 4 hardwired zones
• Advanced zone attribute, user-friendly zone names
• Temperature display and relay signal output
• Support wireless LCD/LED keypad and wireless siren
• Support user code and installer code
• 100 alarm log
• SMS alert, when system: Arm/Disarmed, sensor's low battery, AC power
failure, phone line disconnect
• Reset factory design
• Built-in siren
• Alarm communication via ADEMCO Contact ID protocol
• Backup rechargeable battery, last more than 24 hours
• Work with CCTV system, IP camera

3
Technical Information
• Power supply: AC=100 ~ 230V 50Hz/60Hz
• Working voltage: DC12V 1A
• Static current: < 35mA (when not in charging)
• Alarm current: < 120mA
• Backup Battery: 3.7V 800mA
• Standby time: Around 24 hours
• Charging time: 8 hours
• GSM frequency: 850/900/1800/1900MHz
• GSM Transmission power: 2W
• Receiving and emitting frequency: 433MHz (868MHz optional)
• Wireless transmission distance: ≤100 m (Open space)
• Working condition:Temperature: -10ºC ~ 50ºC Humidity:5% ~ 80%

4
Font panel View

w a
s
e
d
r f
t

y uio
q LCD Display w GSM Signal LED e Fire Alarm
r Burglary t Medical Help y SpeedDial Button
u Home/Stay Arm i Down/Disarm o SET/Exit
a Up/Away Arm s Left/Delete/Log/* d Right/Phone Call/#
f Confirm/Save
5
Back panel View

Anti-Tamper Switch

Speaker

Installation Bracket

Wired Connection Reset


| +12V- |31 32 33 34 |-BELL+|No Com|

SIM Card Slot


ON OFF

DC 12V input jack

Telephone line
6
Arm/Disarm System
Disarm
In keypad, touch then, input xxxx+OK
Remotely via SMS, send SMS content: xxxx0
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 3 to disarm.

Notice
"xxxx" is the current user code, default user code
is "1111", and default admin/installer code is "1234"
Activate Away Arm
The system is working with separate wireless LCD/
In keypad, touch to activate Away Arm. LCD keypads, for activate and deactive operation,
Remotely via SMS, send SMS content: xxxx1 please refer to manual of wireless keypad.
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 1 to activate the Away Arm.

Activate Stay Arm


In keypad, touch to activate the Stay Arm
Remotely via phone, make phone call to alarm
system, after pick up, input xxxx#, you will hear "di"
sound, press 2 to active the Stay Arm

7
Voice Memo/Phone Call
Quick Alarm Make Phone Call
Touch for 2 seconds to trigger fire alarm. When alarm system in disarm status, you can
Touch for 2 seconds to trigger burglary alarm. make phone call via alarm panel. Touch then
Touch for 2 seconds to trigger medical help. input the phone number, touch to make
phone call. OK
Recording Voice Memo The function enables alarm system can be used as
When system is in Disarm status, touch OK a portable cell phone.
for 2 seconds for recording memo.
Maxim recording time is 10 seconds. Pick up Phone Call
If there is a phone call to alarm system, the confirm
Playback Voice Memo circle's LED will light up, and you can touch
When system is in Disarm status, touch OK to pickup phone call. OK
the system will playback the voice memo.
Speed Dial Function
Check System Log When touch " A" or "B" key on the keypad, the
The system can record 100 pieces event log, you alarm system will make the speed dial phone call
can touch with preset phone numbers (eg: the person that
X to check these log, when system
is not in setup status. needs to be notified in case of an emergency, a
carer, Mum or Dad).

8
Basic Alarm Setting
Enter into Setting Status Alarm Receiving Phone Number
When system is in Disarm status, touch This alarm system can totally preset up to 5
then input admin code, default "1234", touch "OK" personal emergency phone numbers for alarm
for confirm, to enter into setting status. receiving.

System Time setting Time Setting Phone Groups 1


When system is setting status, choose the "Time Phone No. Setting
Setting" for modifing the current time. The time SMS Setting Alarm Call >
will automatically back to default, once the alarm Record > 28901540
system is complete OFF.

Time Setting Time Setting Touch "◄► " to select the Alarm Call or Alarm
Phone No. Setting 04:54:08 SMS, then touch "▼ " , you can input the number.
SMS Setting 09/11/2013 1st and 2nd group for setting Alarm SMS, 3rd
Record > THU > group for setting Alarm SMS or Alarm Call, 4th&5th
groups for setting Alarm Call.
Touch " ▲▼ " to select and " X " to delete the Touch " X " you can delete the existing phone
default date, then enter with new time (XX hours, number.
XX minute, XX second). Do same procedure for You need touch "OK" to save, and navigate into
date. next phone number setting menu.
Touch " ▼ " and " ◄► " select the week, touch
"OK" to confirm all settings. Notice: Maximum digitals for phone number input
is 15.

9
Basic Alarm Setting
SMS Number for System Status
The alarm system can preset one phone number
for receiving SMS report of system's status,
including AC power recover, Arm/Disarm, PSTN
OFF, Host Low Voltage, Sensor Low Voltage.
Time Setting SMS Phone No. AC Power Recover Arm/Disarm SMS
Phone No. Setting
SMS Setting 1388888888888 OFF > OFF >
Record >

PSTN Off Host Low Volt Sensor Low Volt

OFF > OFF > OFF >

Touch " X " to delete exist phone number, enter new mobile phone number. Touch " OK" to save the
phone number, it will navigate to event report selection.
Touch "◄►" to select enabled or disable the event report.

AC power recover means when external electricity is recover, the alarm system will send SMS.
Arm/Disarm SMS means when alarm system is Armed or Disarmed, the system will send SMS.
PSTN Off means when fixed phone line is cut or with trouble, the system will send SMS.
Host Low Volt means when backup battery is low, the system will send SMS.
Sensor Low Volt means when battteries run out in wireless sensors, it will send SMS.
10
Advanced Alarm Setting
Record Voice Memo Alarm Delay/Entry Delay
The system allows user to record up to 10 seconds The alarm delay or entry delay can allow user to
voice memo. When alarm phone call is picked up, set alarm delay zones before system set alarm off.
press "5" to listen the voice memo. This allow user enter into specific detection area to
disarm the system without triggering alarm.

Record Record Arm Delay Alarm Delay


Alarm Delay
OFF > Recording Time Siren Setting 10
10 Tone Setting > Seconds

Touch "◄►" to choose "On" to record voice, and Touch " X " to delete exist data, and input new
touch "OK" to start voice recording. seconds e.g 10. It accpet time between 00 - 59.
Touch "OK" to save.
Arm Delay/Exit Delay
The Arm delay or exit delay can allow user to exit Notice: You need go to [Zone attribute] to enable
protected area before system is Armed. The time is which zones are belong to this function, therefore it
adjustabe from 00 to 59 seconds. can work.
Arm Delay Arm Delay
Alarm Delay
Siren Setting 10
Tone Setting > Seconds

Touch " X " to delete default data, and enter new


time. Touch "OK" to save.
11
Advanced Alarm Setting
Siren Setting
It allows siren time setting for each of zones. The siren
time can be set from 00-59 minutes. User can choose
whether use built-in siren or not. The function is useful, if
user want to choose mute alarm.

Arm Delay Zone No. Siren Time Built-in Siren


Alarm Delay
Siren Setting 00 01 On >
Tone Setting > Minute

Touch " X " to delete the zone number, and input new zone number from 00-34. Touch "OK" to save
Touch " X " to delete the siren time, and input new siren time, "00" means disable. Default value is 01
Touch "◄►" to choose "On" to enable built-in siren, and touch "OK" to save.

Tone Setting Temp Alert


Tone setting means the alarm system will make
"beep" sound, when detects system event, such as Off >
telephone line cut, Arm/Disarm, Temperature Alert.

Arm Delay PSTN OFF Tone Arm/Disarm Tone Arm/Disarm Beep
Alarm Delay
Siren Setting Off > Off > Off >
Tone Setting >

12
Call in Setting
Call in Setting
The system can receive the phone call via telephone line and GSM. It allow user to set the ring times
from 1 to 9. When the ring time reach to preset times, it will pick up the phone call for remotely control.

Call in Setting PSTN Call in Tone GSM Call in Tone


Program&Delete
Zone Attribute 9 3
Upload >

Touch " X " to delete exist data, It accpets ring time between1-9. Touch "OK" to save.

Program&Delete
Use this function to program/delete wireless sensors and accessories (remote keyfob, wireless LED/LCD
keypad). The wireless zone number is from 00-30. Zone 00 is for programming wireless remote keyfob or
keypads.

Call in Setting Zone No. Zone No. Zone No.


Program&Delete 00 00 00
Zone Attribute Program Programming Success
Upload > Delete Delete

13
Zone Programming
Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
[program], then touch "OK", the LCD will display [Programming]. Trigger the wireless sensors/accessories
for two times, the LCD display [Success], touch "OK" to save, you can continue to enroll more sensors.

Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "▲▼" to choose
delete, the LCD will display [Success], touch "OK" to save. This will erase the current sensors in the zone
from the alarm system.

Zone Attribute
The system has advanced zone attribute, it allow user to choose each of attribute for the zones, it helps
user to customize the system, which can be more suitable for specific installation. Ensuring the zones with
correct attribute, therefore sensors can work properly.

Call in Setting Zone No. Activate > Zone Chime Off >
Program&Delete 01 0 Defence Line > Smart Sensor Off >
Zone Attribute 00Help >
Upload > Alarm Delay Off >

Touch " X " to delete the zone number, and input new zone number from 00-30. Touch "OK" navigate to
next menu. Touch "OK" you will navigate to last level menu.
Bypass Sensor: Touch ""◄►" to choose "Disable" to deactivate/bypass this zone.
Zone type: Touch "▲▼" to choose defense line, touch "◄►" to change the value from including 0, 1, 2.
Sensor type: Touch "▲▼" to choose sensor type, touch "◄►" to change the sensor type.
Alarm Delay: Touch "▲▼" to choose alarm delay off, touch "◄►" to enable or disable the alarm delay.
Zone Chime: Touch "▲▼" to choose zone chime off, touch "◄►" to enable or disable this function.
14
Zone Attribute
Smart Sensor Off: Touch "▲▼" to choose smart sensor off, touch "◄►" to enable or disable this
function.

Notice:
[0 Defense line] means fire, panic alarms, which are belong to 24 hours emergency zone. It will trigger the
alarm system, even the system in disarm status.
[1 Defense line] means perimeter protection, which is belong to perimeter zone. It will work when alarm
system in both Away Arm and Home Arm modes.
[2 Defense line] means interior protection, which is belong to motion zone. The sensors in this zone will
be activated when system is in Away Arm mode, but will be de-activated, when system in Home Arm/Stay
Arm mode.

Default Zone Type


Zone Number Zone Type Sensor Type Sensors
00 N/A Wireless Remote Keyfob Maximum 10 pcs
01 ~ 10 Emergency Zone Wireless Sensors Panic, Smoke, Gas Leak
11 ~ 20 Perimeter Zone Door sensor, IR beam
21 ~ 30 Motion Zone PIR motion sensor
31 ~ 34 Hardwired Zone Hardwired Sensors

Default zone number for sensor and keyfob for standard alarm kit
Wireless Remote Wireless Door Sensor Wireless PIR motion Wireless Smoke
00 12 21 02

15
Monitored Alarm Setting

Upload
The system can either be used as self-monitoring system or monitored by security company. It's
compatible with ADEMCO Contact ID protocol for alarm monitoring. If you want to link the alarm system
into alarm monitoring centre, you need to do this operation. More over, the system can not only upload
alarm information, also can upload system's status to central monitoring station.

Call in Setting Center Phone No. User Code Upload Status?


Program&Delete
Zone Attribute 911 0001 Off >
Upload >

Touch " X " to delete exist number, and input new alarm monitoring centre number. Touch "OK" to save,
then navigate to next level menu, touch " X " to delete default user code, and input your user code,
touch "OK" to save, then navigate to next level menu, touch "▲▼" to choose disable or enalbe upload
status, touch "OK" to save, navigate to next status selection menu.
Period Test

00000


AC Fail Upload Host Low Volt Sensor Low Volt Manual Test

Off > Off > Off > Off >

16
User/Admin Code Setting

User Code Reset


Navigate to this menu, user can modify the user Navigate to this menu, user can reset the alarm
code. The user code with authorization for Arm/ system. The system will reset to factory status.
Disarm the system via keypad, SMS, phone call, If user have done wrong programming, can not
mobile applications (APP). The default user code be solved, then you can use reset function. It will
is "1111". erase all the user's programming data.
Password Setting Password Setting Password Setting Reset
Pin Setting Pin Setting
Reset #### Reset Off >
Time Arm/Disarm > Auto Arm/Disarm >

Touch "◄►" to choose "On" , then touch "OK" to


reset the alarm system.
Admin Code
Navigate to this menu, user can modify the admin
code. The admin code with authorization for
programming the system. The default admin code
is "1234".

Password Setting Pin Setting


Pin Setting
Reset ####
Time Arm/Disarm >

17
Auto Arm/Disarm

Auto Arm/Disarm
This function can make the alarm system automatically Arm/Disarm in preset time for
everyday.

Password Setting SUN MON


Pin Setting --:-- Away Arm --:-- Away Arm
Reset --:-- Stay Arm --:-- Stay Arm
Auto Arm/Disarm > --:-- Disarm --:-- Disarm

Touch " X " to delete the default time, and input new time e.g: 1200, touch "▲▼" navigate to next time
setting, touch "OK" to save, it will navigate next day for auto arm/disarm setting.

Notice:
The time format should be 12:00, hours then minutes. Wrong time input can not be saved.
Temperature Control
This system is built-in temperature sensor for monitoring onsite temperature. You can set the upper limit
and lower limit to make temperature alert (NC. dry contract output).The temperature range can be from
00° ~ 70° . If you enabled SMS notification, then it will send the text message alert. If choose output OFF,
then the dry contract will be used as alarm output.

Temp Control Temp Upper limit Temp Lower limit


Speed Dial
32 15
Output On > Output Off >

18
Speed Dial Phone Call
Speed Dial
There are two special buttons on the keypad, they are "A, B". User can preset phone number for this two
buttons. When system is in Disarm status, the user can touch "A" or "B" for making speed dial phone call.
The phone number can be the person that needs to be notified in case of an emergency, a carer, Mum or
Dad.

Temp Control A Phone No. B Phone No.


Speed Dial
1008610086 > 10011001 >

Notice:
After finish the setting, you can touch to exit setting status. The system will automactially exit setting
status, when without any operation on keypad.

19
Alarm Handle for User
Receiving Alarm SMS
Once an alarm occurs, the system will send SMS as long as user choose for alarm SMS notification. The
system will send SMS with below content:
(0001)Alarm System: 11 Zone Door Sensor Alarming

Inquiry System's Status


The system allow user to inquiry the system's status, send "User code + C" text message to alarm
system, alarm will reply text message inform you whether it's Armed or Disarmed.

SMS Content:XXXXC

20
Alarm Handle for User
Receiving Alarm Phone Call
Once an alarm occurs, the system will make phone call as long as user choose for alarm call notification.
The alarm systems support remotely control via phone call, including Away Arm/Stay Arm/Disarm, Onsite
voice monitoring, listen voice message, talk back, two-way intercom, recording meno.

When pickup alarm phone call, you will hear the siren sound, after the replay, you can:
• Press "1" on the phone to Away Arm (It will hang up immediately, system will be Away Armed)
• Press "2" on the phone to Stay Arm (It will hang up immediately, system will be Stay Armed)
• Press "3" on the phone to Disarm (It will hang up immediately, system will be Disarmed)
• Press "4" on the phone to listen onsite voice (It will hang up, after 20 seconds delay)
• Press "5" on the phone to listen voice memo
• Press "6" on the phone to talk back (fixed phone number doesn't support this function)
• Press "7" on the phone to record voice memo (Maximum 10 seconds, except fixed phone number)
• Press "8" on the phone to begin two-way intercom (except fixed phone number)
• Press"*" on the phone for alarm confirmation, it will hang up, stop to dial phone call
21
How to Use Wireless Keyfob
Working LED
Program&Delete
Go to [Program&Delete] for programming wireless
remote keyfob, program keyfobs in sequence into
zone 00
Disarm Away Arm
Call in Setting Zone No.
Program&Delete 00
Zone Attribute Program
Stay Arm SOS Upload > Delete

To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n


touch "OK" to confirm, the LCD will display
[Programming]
Now press the " " button for two times, the LCD
will display [Success], then touch "OK" to save.
Arm/Disarm/SOS
Away Arm the system by press: Zone No. Zone No.
00 00
Stay Arm the system by press: Program Success
Delete Delete
Disarm the system by press:
Touch "◄►" to choose "Delete" , then touch "OK"
Trigger SOS alarm by press:
to confirm, the LCD will display [Success], then
touch "OK" to save.

22
How to Use Wireless Door Sensor

Introduction
Wireless door sensors or entry point sensors are the most reliable intrusion detection device for perimeter
protection. The door sensor is adopting reed switch theory, it consists of wireless transmitter and magnetic
two parts. When two parts sperate maximum 1cm, the sensor will send alarm signal to alarm system.

LED Indicator
Program&Delete
Go to [Program&Delete] for programming wireless
remote keyfob, program keyfob in sequence into
zone 11~20

To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n


touch "OK" to confirm, the LCD will display
[Programming]
Tamper Swtich Now separate door sensor for two times, the LCD
will display [Success], then touch "OK" to save.

Zone No. Zone No.


RF transmitter 11 11
Program Success
Panic button Magnetic Battery
Delete Delete

Touch "◄►" to choose "Delete" , then touch "OK"


Notice: to confirm, the LCD will display [Success], then
The door sensor in the package may differ from touch "OK" to save.
manual.
23
How to Use Wireless Door Sensor

Installation
• Remove the insulating protect on battery.
• Mount the transmitter on the door frame and the magnet on the door
• Make sure that the magnet is always on the right side of the transmitter.
• Make sure that the magnet will not be more than 1 cm from the transmitter.
• Attach the transmitter and the magnet with double-sided tape or the screw.
• Avoid placing the detector in areas with large-metallic structures or electrical installations such as boiler
area or counters

Technical Information
• Working voltage: 1.5V LR6
• Static current: ≤30 μA
• Alarm current: ≤40mA
• Emitting frequency: 433MHz /(868MHz optional)
• Transmission distance:≤100 m (Open space)
• Lifespan of battery: ≤ 12 months

Notice:
The door sensor in the package may differ from manual. The specification will change, when use different
model of wireless door sensors.
24
How to Use Wireless PIR Sensor

Introduction
PIR motion sensor is one of common intrusion sensor for instruction detection. It with advantages of large
space protection, lowest energy consumption. It detects infrared energy changes which is caused by
movement of human.

Program&Delete
1. Wide angle fresnel lens Go to [Program&Delete] for programming wireless
2. Alarm LED Indicator remote keyfob, program keyfob in sequence into
w 3. Swivel Bracket zone 21~30

To u c h " ◄ ► " t o c h o o s e " P r o g r a m " , t h e n


touch "OK" to confirm, the LCD will display
q [Programming]
Now triggering PIR sensor for two times, the LCD
e will display [Success], then touch "OK" to save.

Zone No. Zone No.


21 21
Program Success
Delete Delete

Touch "◄►" to choose "Delete" , then touch "OK"


to confirm, the LCD will display [Success], then
touch "OK" to save.

25
How to Use Wireless PIR Sensor
Installation
Due to the wide coverage angle and the swivel bracket, the motion sensor can easily be installed:
• Indoor environment only!
• Wall mounted on the wall and sensor points to entry point of doors
• Wall mounted on corridor to detect movement

Technical Information
• Working voltage: 2x1.5V LR6
• Static current: ≤50 μA
• Alarm current: ≤9.5mA
• Detection angle: ≤ 110°
• Detection distance: ≤ 12 m
• Emitting frequency: 433MHz /(868MHz optional)
• Transmission distance:≤100 m (Open space)
• Lifespan of battery: ≤ 12 months

Notice:
The PIR sensor in the package may differ from manual. The specification will change, when use different
model of wireless PIR sensor.
26
Appendix
Zone Name & CID Code
Item Zone Name CID Code CID Name
00 Help/Medical Alarm E100 Medical
01 Emergency E121 Duress
02 Emergency E120 Panic
03 Fire Alarm E110 Fire
04 Smoke Alarm E111 Smoke
05 Kitchen E130 Burglary
06 Gas Leak Alarm E112 Combustion
07 Tamper Alarm E137 Tamper
08 Heat Alarm E158 High temp
09 Perimeter Zone E131 Perimeter
10 Door E134 Entry/Exit
11 Front Door E134 Entry/Exit
12 Back Door E134 Entry/Exit
13 Side Door E134 Entry/Exit
14 Window E131 Perimeter
15 Glass Break E131 Perimeter
16 Vibration E130 Burglary
17 Motion Zone E132 Interior
18 Garage E130 Burglary
19 Motion E132 Interior

27
Appendix

Item Zone Name CID Code CID Name


20 Lobby/Family room E130 Burglary
21 Bedroom E130 Burglary
22 Book room E130 Burglary
23 Other E140 General Alarm
24 (Door Bell) N/A N/A

Hardwired Zone Connection

Notice:
Hardwired zone number from 31~34. All hardwired zones are disabled/de-activated. If you want to use
the hardwired zones, you need go to [Zone attribute] to enable them.
EOL resistor must be connected to hardwired sensor for zone protection, it can make hardwired sensors
work properly.
"A1" means wired zone, "V1" means DC power (either from alarm panel or separate power supply)
28
Maintenance and Care

This alarm system is a Hi-Tech product with outstanding design and sophisticated technology, and shall
be carefully.
• To make the alarm to operate for a long term stably and to prolong the service life, it's recommended
that:
• Try to put the alarm panel in a dry and well-ventilated location
• Do not put the alarm panel and any wireless sensors in too cold, too hot or dusty places to prevent it •
from curtailing the service lives of electric parts and preventing the plastic shell from distorting.
• Do not put the alarm panel and any wireless sensors in low and too exposed places to prevent children
from touching them or the thieves from finding them
• Reglar testing is necessary for finding and resolving probles in time.
• Regulary check the batteries in all wireless sensors. To ensure normal operations of the system,
replace with new batteries whenever you feel a sensor is not detecting properly.

29
System Note:

You might also like