Data - Sheets DEPA PUMS
Data - Sheets DEPA PUMS
Series M Type DL
Cast Metal Pumps
DE/DB-0001-GB / 04.00 / MD
For general industrial, water/ All models are completely self contai-
waste, construction and mining ned, only requiring connection to ■ Ideal for abrasive, viscous and
duties. pipework and air supply. shear sensitive media, and for
products with entrained solids.
Many years experience in the design
Standard design ■ Tolerance of dry running and
and manufacture of air driven dia-
phragm pumps have resulted in these Features include maintenance free harsh usage.
high performance units. Because of control valve, stainless steel base with ■ Minimal maintenance with no
their compact, lightweight construc- integral anti vibration mounts, drain lubrication required.
tion, they are well suited to portable and vent connections, stainless steel
and mobile applications as well as clamp bands, air intake filter (for DL25 ■ Posivive displacement pumping
fixed installation in process plants. to DL80) and muffler. action minimises product shear.
All types of fluids from water to slur- ■ Completely enclosed units with
Accessories no bearings or rotary seals in the
ries and pastes, including abrasive or
shear sensitive media containing A complete range of accessories product stream.
solids, are handled cost effectively by simplifies operation and enhances ■ Air operation means suitability for
these pumps. flexibility. explosive or hazardous areas.
Choice of just the right Series M unit They include pulsation dampeners, ■ Easy control of flow rate by
to satisfy the requirement in each monitoring and control systems, regulating air supply.
case is facilitated by availability of various transport devices, quick
three different materials for the pump release couplings, adapters etc. ■ No need for electric motors,
housing: special drives or base plates.
For more information, please contact
* Cast Aluminium, AL 233 your local supplier. ■ Easily portable and ready to use
* Ductile Iron, GGG 40 by simply connecting to air
* Cast Stainless Steel, 1.4408 supply.
(SS 316) ■ Can be run against a closed dis-
Series M pumps are manufactured in charge—a vital benefit for use on
five different sizes with standard filling machines.
connections: DN 15 to DN 80, ■ Self priming and submersible.
(1⁄2 in. to 3 in.)
■ Rugged construction in cast
aluminium, ductile iron or cast
stainless steel.
DEPA Air Driven Diaphragm Pumps
Series M Type DL Operating Principle
Double acting, positive displacement by the retraction of the diaphragm
Series M pumps operate with two and the pumped medium flows into
alternating pumping chambers. The the chamber. The left hand dia-
compressed air which drives the unit phragm, which is supported by com-
is admitted through a control valve, to pressed air, simultaneously displaces
the rear of each diaphragm in turn, so the medium present in this chamber.
displacing the medium from alternate
Since the two diaphragms are conn-
pumping chambers.
ected by a common piston rod,
In the pump illustrated, the right hand suction always occurs in one cham-
pumping chamber is in the intake ber whilst discharge is occurring in
position. A vacuum has been created the other.
DL 40 – SA – T T T
Diaphragm
Major subassemblies
Seats
Balls
Pump size Internals
Housing Wetted piston Centre block
Connections 1⁄2 in. DN 15 15 NRS B B B
Cast Steel Cast AA
NBR (Buna N) N N N
Connections 1in. DN 25 25 aluminium aluminium EPDM (Nordel) E E E
Cast Stainless steel Cast FA EPDM (High press.) D – –
Connections 1 ⁄ in. DN 40
12 40 EPDM (grey) G – G
aluminium AISI 321 aluminium
Connections 2in. DN 50 50 (1.4541) FKM (Viton) F F –
PTFE (Teflon) T T T
Connections 3in. DN 80 80 Ductile iron Steel Cast CA Ceramic 1) – – K
aluminium EPDM grey
Ductile iron Steel Cast bronze CX for Type DH U – –
PTFE for Type DH P – –
Cast stainless Stainless steel Cast SA Stainless steel – – R
steel AISI 316 AISI 321 aluminium NBR, steel core – – Y
(1.4408) (1.4541) EPDM, steel core – – W
EPDM, grey with
Cast stainless Stainless steel Cast bronze SX steel core – – X
steel AISI 316 AISI 321 PTFE, steel core – – Z
(1.4408) (1.4541) Conical valve, EPDM – E I
1) For DL15 only
2
Performance characteristics of Series M Type DL cast metal models
40
20
0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000
Viscosity of the transported medium mPa · s/cP
80
60
40
Example: With a suction lift of 4 mWC,
the pumping rate decreases by about
20 20%. This figure varies with different
pump configurations.
0
0 2 4 6 8 10 mWC
Suction head
3
Extremely rugged construction
reduces downtime to a minimum.
DEPA pumps have been designed in
such a way that all components in
contact with the product can be dis-
assembled and reassembled within a
few minutes. This means that servicing
work is reduced to the absolute mini-
mum.
DEPA air driven diaphragm pumps
have been developed as a modular
system. Consequently, many compo-
nents—some of which are common to
all versions—are mutually compatible
and interchangeable.
This flexible construction allows quick
and simple changing of the internals
for all Type DL models, to fulfil different
applications.
Dimensions for
all cast metal sizes
Discharge
Size
15 25 40 50 80
A 156 190 220 280 350
Air connection B 190 236 310 412 512
C 180 241 305 414 522
D 225 322 406 540 680
E 31 61 72 88 105
F 28 35 50 65 80
Suction G 34 84 84 105 105
H – 71 93 125 160
I 90 141 179 245 304
K 120 200 255 340 420
Air 1⁄4 in. ⁄ in.
38 ⁄ in.
38 ⁄ in.
34 ⁄ in.
34
connection
All dimensions shown in mm
There is a DEPA diaphragm pump structions: cast metal, solid plastic and drum pumping of hard-to-handle
for practically every liquid that and highly polished stainless steel drum contents.
flows. (CIP compatible). Special purpose
DEPA air driven diaphragm pumps are designed models are available for For more information please contact
available in three different basic con- powders, high pressures up to 21 bar your local supplier.
DE/DB-0002-GB / 02.99 / MD
Ideal for closed delivery (dead Standard Equipment
head) applications or where air ■ Exceptionally economical in
Maintenance free control system, operation against a closed
pressure is abnormally low.
stainless steel base frame with inte- discharge (i.e. filter press). No
DEPA air driven diaphragm pumps gral anti-vibration mounts, flanged special control devices required.
provide a cost saving solution for construction, air inlet filter and a new
dead head applications since they design muffler. Drain and vent ■ Diaphragm is pressure loaded
require no costly controls. Due to the connections are also provided. giving equal pressure on both
pressure compensation between the sides of the diaphragm.
air and product sides, the pump Further Accessories ■ Good performance on low
simply stops working in these pressure pumping duties where
Pulsation dampeners, monitoring and
conditions, without generating heat, air supply pressure is low.
control systems, various transport
wear or leakage.
devices, plus various couplings and ■ Ideal for abrasive, viscous, shear
Thanks to these features, DEPA air adaptors for suction and discharge sensitive and solids bearing
driven diaphragm pumps have been connections and for air connections. media.
widely used for filter press feeding
duties for many years. Standard ■ Tolerance of dry running and
Series M models already achieve 6.5 harsh usage.
bar filter pressure with an applied air ■ Minimal maintenance with no
pressure of 7 bar. Many operators lubrication or oil required.
want still higher pressures for greater
filter press efficiency and the DB High ■ Completely enclosed units with
Pressure version of the DEPA Series no bearings or rotary seals in
M air operated diaphragm pumps has contact with the product stream.
been developed to fulfil this ■ Air operation means suitability for
requirement. These pumps can explosive and hazardous areas
achieve a delivery pressure of 21 bar plus easy control by simply
with a driving air pressure of 6 bar. regulating the air supply.
■ No need for electric motors,
special drives or base plates.
■ Easily portable and ready to use
by simply connecting to air
supply.
■ Can be run against a closed dis-
charge—a vital benefit for use on
filling machines and filter
presses.
■ Self priming.
■ Rugged construction in ductile
iron or cast stainless steel.
■ Three connection sizes:
1in., 11⁄2 in. and 2in.
DEPA Air Driven Diaphragm Pumps
Operating Principle of the Type DB High Pressure Range
DEPA Series M pumps deliver the
Discharge
pumped medium alternately via two
pump chambers. In this case, driv-
ing air enters through the control
valve at the rear of the correspond-
ing diaphragm in operation, so dis-
Process side
Process side
placing the medium from alternate
side
pump chambers.
The pressure multiplier increases the
pressure of the incoming air. With an
Air
air supply pressure of 6 bar, a maxi-
mum pumping pressure of 21 bar
can be attained.
Under load or against a closed dis-
charge, the pump will stop and hold
the given pressure without stress on
the pump components and without Suction
need of additional control devices.
DB 40 – CA – DE E
Diaphragm
Major subassemblies
Seats
Balls
Pump size Internals
Housing Wetted piston Centre block
Connections 1”, DN 25 25 NRS B B –
Ductile iron Steel Cast CA1) NBR (Buna N) N N –
Connections 11⁄2 ”, DN 40 40 aluminium EPDM (Nordel) E E –
EPDM (high press.) D – –
Connections 2”, DN 50 50 Cast stainless Stainless steel Cast SA1) EPDM (grey) G G –
steel AISI 321 aluminium FKM (Viton) F F –
AISI 316 (1.4541) PTFE (Teflon) T T T
(1.4408) Stainless steel – – R
NBR, steel core – – Y
EPDM, steel core – – W
EPDM, grey with
– – X
steel core
PTFE, steel core – – Z
2
Performance characteristics of Series M Type DB High Pressure Range
40
20
0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000
Viscosity of the transported medium mPa · s
80
60
40
Example: With a suction lift of 4 mWC,
the pumping rate decreases by about
20 20%. This figure varies with different
pump configurations.
0
0 2 4 6 8 10 mWC
Suction head
3
Extremely rugged construction SA
reduces downtime to a minimum.
DEPA air operated diagphragm pumps
have been designed in such a way that
all components in contact with the
product can be disassembled and
reassembled within a few minutes.
This means that servicing work is
reduced to the absolute minimum.
DEPA air operated diaphragm pumps
have been developed as a
modular system. Conse-
quently, many components—
some of which are common
to all versions—are mutually
compatible and interchange-
able.
This flexible construction allows quick
and simple changing of the internals
for all Type DB models, to fulfil different
applications.
M
D
F 35 50 65
J
G 84 84 105
L
H
H 71 93 125
J 141 179 245
K 200 255 340
E
Suction
F L 165 165 165
G
A K M 380 380 380
B
N 269 269 320
Dimensions in mm
DE/DB-0003-GB / 03.98 / MD
DEPA Series DP pumps are manu- The values given are for guidance
factured in three sizes, in a variety only. Under some circumstances, if ■ DEPA powder pumps are portable
of materials such as polished special precautions are taken, they and mobile.
stainless steel, aluminium and can be exceeded.
■ Low product velocities, compared
cast iron, to suit a variety of appli-
with other methods of powder
cations for powder conveying. Reliable Operation pumping, result in gentle product
These pumps employ the well
On the suction side, DEPA Series handling.
established operating principle of
DP air operated diaphragm pumps
DEPA air operated diaphragm ■ Lower cost and more efficient
operate in principle like vacuum
pumps. powder transfer than mechanical
cleaners. Then, the product enters
methods.
The DP125 model, with a flow rate the suction chamber and is dis-
up to 2400 kg/h, is the largest air charged on the next stroke. ■ Because of the low air to product
operated diaphragm pump in the ratio (typically 1:3 to 1:5), less air
world. need be extracted on the dis-
In developing the optimum DEPA charge side.
pump to fulfil the requirements of
powder transfer, the suction and
discharge manifolds of the DP
Series have been designed with a
“Y” configuration in order to mini-
mise bends and curves and provide
as smooth a flowpath as possible.
This arrangement takes up more
space than the standard DEPA
manifold design but makes a drama-
tic improvement to the flow charact-
eristics of the powder through the
pump.
All DP Series pumps have connect-
ions that allow fluidising equipment
such as aeration valves to be used.
When pumping product from open
containers, a suction lance is norm-
ally attached to the suction hose to
allow fluidisation of
the product. To
ensure long term
dependable oper-
ation, the product
should be properly
fluidised. Granules
or crystalline media
can only be pump-
ed under certain
conditions—please
check with your
DEPA supplier.
Bulk density of the
powder must not
exceed 500 gm/l
and the particle
size must be under
100µ (microns).
Dimensions
Dimensions for all sizes of DEPA Series DP powder pumps. All dimensions in mm.
The dimensions are for guidance only and should not be used for installation purposes.
Certified dimensions will be supplied on request.
Suction
L
See Note 1
Type DP 125
A B C D E F G I K L
D
658 983 1602 1940 330 1027 240 880 1110 529
I
125mm 100mm
F
A K
C
B
DE/DB-0004-GB / 12.97 / MD
For use with corrosive and abrasi- Electrically conductive, non metallic
■ Designed for resistance to corro-
ve media in chemical processing, DEPA pumps can be constructed of
sive media and environments
electroplating, effluent treatment both PP and PTFE, providing a surface with rugged non metallic cons-
and similarly arduous applications. resistance of less than 106 ohms. truction and components.
DEPA Series P pumps with solid, non The pumps can be electrically earthed.
■ Ideal also for abrasive, viscous
metallic components have been devel- and shear sensitive media, and
oped to transfer a wide span of cor- Standard design for products with entrained
rosive liquids, slurries, pastes and solids.
Features include overall corrosion resis-
sludges for which pumps of metal
tant construction, maintenance free ■ Air operation plus electrically
construction fail to offer the necessary
control valve, stainless steel base with conductive plastic housing
chemical resistance. The pump hous-
integral anti vibration mounts, stainless means suitability for explosive or
ings are machined from solid Polypro-
steel clamp bands, muffler, air intake hazardous areas.
pylene (PP) or Polytetrafluorethylene
filter and flange connection for models
(PTFE). The elaborate manufacturing
DL 25 to DL 80. ■ Tolerance of dry running and
process involved ensures the highest harsh usage.
possible stability of form and thus the
A complete range of accessories ■ Minimal maintenance with no
pumping pressure capability is maint-
simplifies operation and enhances lubrication required.
ained in line with standard DEPA cast
flexibility.
metal pump versions. In addition, the ■ Positive displacement pumping
solid PP and PTFE form also provides Accessories include pulsation dampen- action minimises product shear.
complete external resistance to corro- ers, monitoring and control systems,
sive environments. various transport devices, quick release ■ Completely enclosed units with
couplings and adapters. For more infor- no bearings or rotary seals in the
Choice of correspondingly stable, product stream.
mation please contact your local agent.
corrosion resistant materials is avail-
able for the diaphragms, valve balls ■ Easy control of flow rate by regul-
and valve seats. See page 2. ating air supply.
DL 40 – PP – EEE
Diaphragm
Major subassemblies
Seats
Balls
Pump size Internals
Housing Wetted piston Centre block
Connections 1⁄2 in.3) DN 153) 15 PP1) PP PP PP NRS B B B
NBR (Buna N) N N N
Connections 1in. DN 25 25 PP electr. PP electr. PP electr. EPDM (Nordel) E E E
PL
conductive conductive conductive EPDM (grey) G – G
Connections 1 ⁄ in.
12 DN 40 40 FKM (Viton) F F –
PTFE2) PTFE PP PT
Connections 2in. DN 50 50 PTFE (Teflon) T T T
PP electr. PP electr. PP electr. Stainless steel – – R
Connections 3in. DN 80 80 TL
conductive conductive conductive NBR, steel core – – Y
EPDM, steel core – – W
EPDM, grey with
– – X
1) Polypropylene steel core
2) Polytetrafluorethylene PTFE, steel core – – Z
3) Flange connection optional Cone valve, EPDM – E I
2
Performance characteristics of Series P Type DL non metallic models
3.5 4.9 6.3 SCFM SCFM 14 18 21 25 28
bar Air consumption 0.1 0.14 0.18 Nm3/min. bar Air consumption Nm3/min. 0.4 0.5 0.6 0.7 0.8
DL 15 DL 25
Performance
Performance at 7 bar air
at 7 bar air supply pressure
supply pressure
Total discharge head
DL 40 DL 50
Performance Performance
at 7 bar air at 7 bar air
supply pressure Total discharge head supply pressure
Total discharge head
46 53 60 80 95 SCFM
bar Air Consumption 1.3 1.5 1.7 2.2 2.7 Nm3/min.
DL 80
Performance
at 7 bar air
supply pressure Example: To help you select the correct pump size
Required pump rate is 4 m3/h and required total discharge head is 30m.
The correct selection in DL 25, the required air pressure is 5 bar and the
air consumption is 0.5 Nm3/min.
Total discharge head
40
20
0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000
Viscosity of the transported medium mPa · s/cP
80
60
40
Example: With a suction lift of 4 mWC,
the pumping rate decreases by about
20 20%. This figure varies with different
pump configurations.
0
0 2 4 6 8 10 mWC
Suction head
3
Extremely rugged construction
reduces downtime to a minimum.
DEPA pumps have been designed in
such a way that all components in
contact with the product can be disas-
sembled and reassembled within a few
minutes. This means that servicing
work is reduced to the absolute mini-
mum.
DEPA air driven diaphragm pumps
have been developed as a modular
system. Consequently, many compo-
nents—some of which are common to
all versions—are mutually compatible
and interchangeable.
This flexible construction
allows quick and simple
changing of the internals
for all Type DL models, to fulfil different
applications.
Dimensions for
all non metallic models
Size
154) 25 40 50 80
A 170 207 267 340 418
B 212 264 353 450 558
C 185 252 334 448 578
Discharge
D 265 370 484 622 785
E 60 62 80 91 107
F 28 80 92 126 125
Air connection
G 55 82 86 123 153
I 95 107 148 251 316
K 195 230 255 340 420
Air
connection ⁄4 in. ⁄ in. ⁄ in. ⁄ in. ⁄ in.
1 38 38 34 34
Suction
4) Dimensions without flange
There is a DEPA diaphragm pump structions: cast metal, solid plastic and drum pumping of hard-to-handle
for practically every liquid that and highly polished stainless steel drum contents.
flows. (CIP compatible). Special purpose
DEPA air driven diaphragm pumps are designed models are available for For more information please contact
available in three different basic con- powders, high pressures up to 21 bar your local supplier.
DE/DB-0005-GB / 09.01 / MD
The new pump generation PM is a further develop- These new DEPA pumps have all the advantages of
ment of DEPA’s proven and successful polypropylene Air Operated Diaphragm pumps, dry running, self-
pumps series. priming, gentle product handling and the ability to stall
against closed discharge lines.
The development offers a combination of modern
industrial design combined with the daily require- Various options allow a wide variety of applications for
ments of pumps, like temperature, chemical resis- the pumps.
tance and high mechanical strength.
Internal and external air valves, ANSI, DIN and JIS
The computer-aided design of the injection moulding flanges and screw connections are available.
achieves a consistant high quality with excellent sur-
face finish for low flow resistance and good abrasion For the product wetted parts (diaphragms, valve seats
resistance. and valve balls) there are several elastomer materials
available.
The result of the new design offers a strong and com-
pact type of construction. Flow rate max. 9 m3/h at max. 7 bar.
DEPA Air Operated Diaphragm Pumps
Series P
Plastic Pump Type DL15-PM
Technical Specification
Product wetted parts
Housing material: PPH injection moulded
Elastomer material: NRS, NBR, EPDM, FKM, PTFE
for diaphragms, valve seats, balls
Suction and discharge
connection: R 1⁄2”, female thread
Non-wetted parts
Centreblock material: PP
Air valve internal: brass, brass nickel plated
Product temperature max.: 60 °C
Suction lift max.: 2.5 m
Solid size max.: 2.5 mm
Pump weight: 3.5 kg
Flow rate: 2,2 m3/h at 7 bar max.
Performance curves
7 0.6
Pressure head in bar
Air pressure
7 bar / 100 PSI Air pressure 7 bar / 100 PSI
6 0.5
6 bar / 6 bar /
86 PSI 86 PSI
5 5 bar / 5 bar /
0.4 70 PSI
70 PSI
4 4 bar /
4 bar /
57 PSI 0.3 57 PSI
3 3 bar /
3 bar / 43 PSI
43 PSI 0.2
2 2 bar /
2 bar /
29 PSI 29 PSI
1 0.1
0 0
0 0.5 1 1.5 2 2.5 3 0 0.5 1 1.5 2 2.5 3
Flow rate in m3/h Flow rate in m3/h
Dimension drawing
(Standard)
Dimensions
in mm
A 170,5
E
B 212,5
C 60,0
D
D 185,0
E 265,0
J
F 112,5
G 134,5
H 40,0
C
J 155,0
H
K 28,0
L 55,0
2
DEPA Air Operated Diaphragm Pumps
Series P
Plastic Pump Type DL25-PM
Technical Specification
Product wetted parts
Housing material: PPH injection moulded
Elastomer material: NRS, NBR, EPDM, FKM, PTFE
for diaphragms, valve seats, balls
Suction and discharge
connection: Standard PVC-Loose flange DN 25
DIN 2653, special options Combined
DIN/ANSI, ANSI-, JIS-Flange or R1”
female thread
Non-wetted parts
Centreblock material: PP
Air valve internal: brass, brass nickel plated
Air valve external: coated
Clamp band: 1.4301
Product temperature max.: 60 °C
Suction lift max.: 4m
Solid size max.: 4 mm
Pump weight: 8.4 kg
Flow rate: 6,6 m3/h at 7 bar max.
Performance curves
7
Pressure head in bar
1.6
Air consumption in Nm3/min
Air pressure
7 bar / 100 PSI
6 1.4
6 bar / Air pressure 7 bar / 100 PSI
86 PSI 1.2
5 5 bar / 6 bar /
70 PSI 86 PSI
1
4 5 bar /
4 bar / 70 PSI
57 PSI 0.8
4 bar /
3 57 PSI
3 bar /
43 PSI 0.5
3 bar /
2 43 PSI
2 bar / 0.4
29 PSI 2 bar /
1 29 PSI
0.2
0 0
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Flow rate in m3/h Flow rate in m3/h
Dimension drawing
(Standard)
Dimensions
in mm
A 264
B 287
C 115
D 85
E 372
F 252
G 184
H 144
L
J 40
K 188
L 208
M 84
N 85
3
DEPA Air Operated Diaphragm Pumps
Series P
Plastic Pump Type DL40-PM
Technical Specification
Product wetted parts
Housing material: PPH
Elastomer material: NRS, NBR, EPDM, FKM, PTFE
for diaphragms, valve seats and balls
Suction and discharge
connection: Standard PVC-Loose flange DN 40
DIN 2653, special options Combined
DIN/ANSI, ANSI-, JIS-Flange or R11⁄2”
female thread
Non-wetted parts
Centreblock-material: PP
Air valve internal: brass, brass nickel plated
Air valve external: coated
Clamp band: 1.4301
Product temperature max.: 60 °C
Suction lift max.: 5.5 m
Solid size max.: 6 mm
Pump weight: 15.1 kg
Flow rate: 9 m3/h at 7 bar max.
Performance curves
7
Pressure head in bar
1.6
Air consumption in Nm3/min
Air pressure
7 bar / 100 PSI Air pressure 7 bar / 100 PSI
6 1.4
6 bar /
86 PSI
1.2
5 6 bar /
5 bar / 86 PSI
70 PSI 1
4 5 bar /
4 bar / 70 PSI
57 PSI 0.8
4 bar /
3 57 PSI
3 bar /
43 PSI 0.5
3 bar /
2 43 PSI
2 bar / 0.4
29 PSI 2 bar /
1 29 PSI
0.2
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 0 1 2 3 4 5 6 7 8 9 10 11 12 13
Flow rate in m3/h Flow rate in m3/h
(Curves based on water [1cPs] ambient temp. and air supply 7 bar)
Dimension drawing
(Standard)
Dimensions
in mm
A 353
B 267
C 150
D 110
E 490
F 335
G 240
H 190
L
J 40
K 245
L 265
18
M 92
N 94
DE/DB-0007-GB / 09.01 / MD
For hygienic pumping duties DEPA Series L Type DH pumps are
throughout food, beverage, manufactured in four sizes with ■ Designed for hygienic processes
pharmaceutical, biotechnology connections: DIN15 to DN50. The with highly polished stainless
and cosmetic manufacturing option of DIN 11851 Tri-clamp, SMS steel construction, CIP and SIP
processes. etc., is also available. compatibility and easy manual
cleaning.
DEPA Series L, Type DH Pumps are
suitable for chemical cleaning in Standard design ■ Use of oil-free air obviates any
place (CIP) or steam sterilisation in risk of product contamination.
Overall corrosion resistant
place (SIP). They are designed for ■ Ideal for abrasive, viscous and
construction incorporates all metallic,
transfer of abrasive, viscous or shear shear sensitive media, and for
product wetted parts in 316 stainless
sensitive media, including products products with entrained solids.
steel. Other features include
with entrained solids and require
maintenance free control valve, ■ Tolerance of dry running and
minimal maintenance.
stainless steel base with integral anti harsh usage.
Because of the low shear, positive vibration mounts, muffler and air
displacement pumping action, intake filter for sizes 25 to 50. ■ Minimal maintenance with no
delicate products including entire lubrication required.
chunks of fruit, vegetables and meat ■ Gentle positive displacement
Accessories
can be transported without damage. pumping action minimises
This gentle action also avoids A complete range of accessories product shear.
excessive wear on pump internal simplifies operation and enhances
components. These pumps use flexibility. They include pulsation ■ Completely enclosed units with
oilfree air and require no oil or grease dampeners, monitoring and control no bearings or rotary seals in the
lubrication, so obviating any risk of systems, various transport devices, product stream.
product contamination by lubricants. quick release couplings, adapters ■ Air operation means suitability for
etc. explosive or hazardous areas.
Incorporation of the widely used,
threaded milk connections (DIN For more information, please contact ■ Easy control of flow rate by
11851) ensures that the pumps can your local supplier. regulating air supply.
be quickly and easily dismantled for
visual inspection. Choice can be ■ No need for electric motors,
made from a variety of construction special drives or base plates.
materials for the internal diaphragms ■ Easily portable and ready to use
and valve balls, to meet exact by simply connecting to air
requirements. See page 2. supply.
■ Can be run against a closed
discharge—a vital benefit for use
on filling machines.
■ Self priming and submersible.
DEPA Air Driven Diaphragm Pumps
Series L Type DH Operating Principle
Double acting, positive displace- created by the retraction of the
ment Series L pumps operate with diaphragm and the pumped medi-
two alternating pumping chambers. um flows into the chamber. The
The compressed air which drives right hand diaphragm, which is
the unit is admitted through a supported by compressed air,
side
control valve to the rear of each simultaneously displaces the medi-
Process side
diaphragm in turn, so displacing um present in this chamber.
the medium from alternate pump-
Air
Since the two diaphragms are
ing chambers.
connected by a common piston
In the pump illustrated, the left rod, suction always occurs in one
hand pumping chamber is in the chamber whilst discharge is occur-
intake position. A vacuum has been ring in the other.
Diaphragm
Major subassemblies
Seats
Balls
Pump size Internals 3)
Housing Wetted piston Centre block
Connections 1⁄2 in. Tri-Clamp 15 EPDM gray for
Polished Polished Chromium UL
DH range U – –
Connections 1in. Tri-Clamp 25 stainless stainless plated 2) PTFE for
steel steel cast bronze Series DH P – –
Connections 11⁄2 in. Tri-Clamp 40 AISI 316 AISI 316 Stainless steel – – R
(1.4571) (1.4571) EPDM grey with
Connections 2in. Tri-Clamp 50
steel core – – X
PTFE steelcore – – Z
1) Series L Type DH has been reviewed and accepted by the Dairy Grading Branch, NRS – – B
USDA for use in dairy plants surveyed and approved for USDA grading service.
2) Models wit externally mounted air valves, aluminium chromium plated
40
20
0
0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000
Viscosity of the transported medium mPa · s/cP
80
60
40
Example: With a suction lift of 4 mWC,
the pumping rate decreases by about
20 20%. This figure varies with different
pump configurations.
0
0 2 4 6 8 10 mWC
Suction head
3
Extremely rugged construction
reduces downtime to a minimum.
DEPA pumps have been designed in
such a way that all components in
contact with the product can be dis-
assembled and reassembled within a
few minutes. This means that servicing
work is reduced to the absolute mini-
mum.
DEPA air driven diaphragm pumps
have been developed as a modular
system. Consequently, many compo-
nents—some of which are common to
all versions—are mutually compatible
and interchangeable.
This flexible construction allows quick
and simple changing of the internals
for all Type DH models, to fulfil differ-
ent applications.
Air connection E 73 81 71 86
F 32 50 55 57
G 34 82 82 107
I 155 249 307 385
K 180 335 335 335
Suction Air
connection R ⁄4in. R3⁄8in. R3⁄8in. R3⁄4in.
1
Dimensions in mm
There is a DEPA diaphragm pump structions: cast metal, solid plastic and drum pumping of hard-to-handle
for practically every liquid that and highly polished stainless steel drum contents.
flows. (CIP compatible). Special purpose
DEPA air driven diaphragm pumps are designed models are available for For more information please contact
available in three different basic con- powders, high pressures up to 21 bar your local supplier.