dormakaba RFID Encoder

System 6000

Installation Instructions
PK3695 - 2019 - 03

EN
Table of Contents

1. System 6000 Encoder Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. Testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3. Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Parts List
- dormakaba RFID Encoder (P/N: CE74750)

- Ethernet Cable (Optional) (P/N: 71590-10)

- USB A to Micro B USB cable (P/N: 71680)

Prerequisites
Hardware: dormakaba RFID encoder version 1.012 or greater.

Software: System 6000 version 5.6.8 or greater.

Setup: You can use the power over Ethernet (POE) to apply power on your device or use the USB cable
connected to a 5V adapter.

The encoder communicates with a TCP/IP communication protocol.

The following ports must be open in the firewall:


TCP Port 28000 (Server Inbound)
TCP Port 9090 (Server Inbound)

© 2018 dormakaba USA, Inc. All trademarks and registered trademarks are the property of their respective owners.

2 dormakaba RFID Encoder PK3695 03-19


System 6000 Encoder Setup

1- Connect the USB cable to the computer and to the encoder.

2 - Open the CRS program and log in. Choose the “Add” option under Settings.

3 - Choose the “Kaba RFID” option under Network Encoder Type and press “Configure Kaba RFID”.

dormakaba RFID Encoder PK3695 03-19 3


System 6000 Encoder Setup

4 - Press the drop-down menu and select the encoder you would like to configure.
(The encoders MAC address should appear).

Enter in a Station ID.

Choose either the TCP/IP configuration or the USB configuration.

Select “Obtain an IP address automatically” for DHCP Configuration.

OR

Enter specific IP configuration for Static IP.

4 dormakaba RFID Encoder PK3695 03-19


Testing

1 - Log into Client, choose the System tab, and choose the Terminal Settings option.
Set the Encoder Station to the new Encoder Station ID.

2 - Attempt a key interrogation to test the encoder connection.

dormakaba RFID Encoder PK3695 03-19 5


Troubleshooting

USB cable must be attached whenever you are configuring the encoder.

After Configuration: Connect a USB Cable for USB communication or an Ethernet cable with POE for
TCP/IP communication.

**Do not connect USB cable to PC when configured for TCP/IP communication**
**If ethernet connection is not POE, use the included USB power adapter for power**

Connection Issues:

• Ensure the encoder’s Station ID is selected in the Client Terminal Settings

• Ensure that Kaba Encoder USB Bridge Service is running

• Ensure that Kaba IP Encoder Service is running (KIPES)

• Ensure the CRS is running

• Ensure you are using the correct cable (USB or Ethernet)

• Confirm that the minimum prerequisite software (System 6000 5.6.8.0) and firmware (Encoder
V.1.012) is installed

• Remove the power from the encoder, wait five seconds and power it back up (Repeat as
necessary)

• Restart KIPES and Kaba Encoder USB Bridge Service

• Restart PC

Configuration Issues:

• Make sure that the encoder is not already assigned in the CRS

• Make sure that the USB cable (P/N 71680) is attached. (Third party cables may not function
properly)

• Ensure station ID entered was less than 16 characters

• If server not correctly assigned on workstation, do the following:


Edit the Saflok.ini file located in the SaflokV4 folder to enter the server IP address under the
database section. Save the file and test encoder function.

Example:
[Database]
LinkPath=\\xx.xxx.xxx.xx\SaflokData\
MsgLinkPath=\\xx.xxx.xxx.xx\SaflokData\

6 dormakaba RFID Encoder PK3695 03-19


dormakaba USA Inc.
Customer Services & Support
Saflok: 1.800.999.6213 / + 1.248.837.3700

General Information:
dormakaba.us
Online Consumable Orders:
www.saflokstore.com
To access all of our easy steps, please
visit our Support Website:
www.kabalodgingsupport.com

Subject to change without notice


PK3695 03-19

www.dormakaba.com

You might also like