Delta-Q IC650: 650 W Industrial Battery Charger
Delta-Q IC650: 650 W Industrial Battery Charger
24 V / 27 A 36 V / 18 A 48 V / 13.5 A
Delta-Q IC650
650 W Industrial Battery Charger
Capable of charging lead acid (wet, AGM, gel) and lithium battery chemistries, the IC650 Charger is available in on- and
off-board configurations. Optional CAN bus communication ensures seamless machine integration and AC/DC cabling is
completely customizable. Applications include: scissor lifts, lift trucks, floor care machines, and golf cars.
R NI A E N
FO
ER
I
CAL
GY
delta-q.com
COM
NT
LIA
ISS P
M
ION COM
IC650 Charger Specifications
DC Output 24 VDC 36 VDC 48 VDC
Maximum DC output voltage 36 V 54 V 72 V
Maximum DC output current 27.1 A 18.1 A 13.5 A
Maximum DC output power 650 W
Deep discharge recovery
1.2 V 1.8 V 2.4 V
(minimum voltage)
Maximum C3 interlock 1.5 A
signal current (15 A with external interlock device, 24V model only)
Usability Features
Battery type Lead acid (Wet / AGM / GEL), lithium
Optional CAN bus
Reverse polarity Electronic protection with auto-reset
communication for
Short circuit Electronic current limit
machine integration or
lithium BMS
AC Input
AC input voltage range 85-270 VAC Multi-color LED indicator
Nominal AC input voltage 100-240 VAC for AC source, battery
Nominal AC input frequency 50 / 60 Hz status, charging, error, fault
Maximum AC input current 7.5 A Numeric display for charge
Nominal AC input current 7.3 A @ 100 VAC 6.0 A @ 120 VAC profile, alarm/fault codes
3.1 A @ 230 VAC 2.9 A @ 240 VAC Field programmable with
Power factor >0.99 @ 120 VAC >0.98 @ 230 VAC up to 25 charge profiles
Auto-recharge for low
Regulatory voltage in maintenance
Efficiency 93.5% peak, California Energy Commission compliant
mode
Safety UL1564, CSA 107.2, EN 60335-2-29, AZ/NZS60335 (RSM)
OEM customizable, field
Emissions FCC Part 15 / ICES 003 Class A, EN55011, EN 61000-6-4
replaceable cable design
Immunity EN 61000-3-2, EN 61000-3-3, EN 61000-6-2
Optional carrying handle
Mechanical Dimensions
Dimensions 25.2 x 18.6 x 8 cm (9.9 x 7.3 x 3.1”)
80mm
Weight < 3 kg (< 6.5 lbs)
(3.1”)
AC input connector IEC320 / C14 (requires country-specific cord)
DC output connector M6 threaded fasteners for ring terminals
25
Service port Sealed (IP66) USB 2.0 Host Port (Type A) with dust cover 2m
(9. m
9”) m
Mounting holes Allows for safe installation on shelf, wall or bulkhead 6m
18 .3”)
Cooling Normal operation in any orientation with passive cooling (7
Environmental
Enclosure IP66 (NEMA4)
Mechanical shock & GMW3172
vibration
Corrosion & humidity Web: delta-q.com
Thermal fatigue
Phone: +1.604.327.8244
E-mail: [email protected]
Operating temperature -40oC to +65oC (-40oF to 149oF) Derated at >40oC (104oF)
Storage temperature -40oC to +85oC (-40oF to 185oF)
Delta-Q Technologies
3755 Willingdon Avenue
Visit delta-q.com/products to view the complete Delta-Q product portfolio.
Burnaby, BC V5G 3H3
Canada
© 2016 Delta-Q Technologies Corp. All rights reserved.
(DOCUMENT 720-0011 R6 Date: 18/07/2016)